5303 mini-concept how to setup an intra-aortic balloon pump

9
How To Mix Angiomax & Administer During a PCI NUR 5303 Lauren Gomez April 10, 2016 LCU MSN Program

Upload: lauren-crump

Post on 15-Apr-2017

36 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

How To Mix Angiomax &

Administer During a PCINUR 5303

Lauren GomezApril 10, 2016

LCU MSN Program

Page 2: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

OBJECTIVES:

Mix Angiomax vial with sterile water Inject Angiomax into 50 ml bag of D5W Prime IV tubing Start Administration of Angiomax

Page 3: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

Angiomax vial, 10ml vial of Sterile Water, and 50 ml bag of D5W from the Pyxis.

10ml syringe and blunt needle IV Tubing Set IV Pump

STEP 1 Gather Supplies

Page 4: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

Step 2 Attach blunt tip needle to 10ml syringe Open sterile water vial and insert needle with

attached syringe into vial Draw up 5ml’s of sterile water into syringe Take lid off of Angiomax vial and insert needle with

syringe with 5ml’s of sterile water into Angiomax vial and slowly swirl until all contents are dissolved

Using the same needle and syringe draw up contents from the Angiomax vial that was just mixed

Page 5: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

STEP 3 Grab the 50ml bag of D5W Take off the cap to the D5W bag and insert needle with

syringe that has the mixed Angiomax solution and inject into the D5W bag.

Gently agitate D5W bag to ensure mixture of solution Retrieve IV Tubing and ensure roller clamp is closed Take off foil cover on D5W bag and insert IV tubing

spike into 50ml bag of D5W now mixed with Angiomax and hang on IV pump.

Fill upper chamber of IV tubing halfway before priming tubing & ensure that roller clamp is still closed

Page 6: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

STEP 4 Invert the IV tubing prior to the roller clamp while priming to

help aid in minimizing air bubbles. Open the roller clamp and allow the Angiomax to prime the

IV tubing. Once the Angiomax has passed the filter part of the tubing it

does not need to be inverted and the rest of the tubing can be primed until Angiomax reaches the end of the tubing.

Hook the tubing up to the patient’s IV access

Page 7: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

START THE ANGIOMAX ON THE PUMP

All Pumps are different however when putting on the pump follow the guardrail instructions and double check to make sure it is the same concentration that you have just mixed

Enter the patient’s weight in kilograms and the pump should prompt you to the correct next steps for successful administration of Angiomax to your patient during a PCI during an Angiogram.

Page 8: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

CLOSURE:

Gather supplies Mix Angiomax Prime Tubing Connect to Patient Start Administration via IV Pump based on Patient’s kilograms

Page 9: 5303 Mini-Concept How to Setup an Intra-Aortic Balloon Pump

REFERENCES Angiomax (bilvalirudin) for injection. Retrieved April 10, 2016 from

http://www.angiomax.com