SHOWROOM 11 Fiveways Boulevard Keysborough VIC 3173 PHONE 1300 00 1800 FAX (+613) 9798 5133 enquiries@huntheat.com.au IMMERGAS ARES PRO FLOOR STANDING BOILER MANUFACTURED BY: Large water content condensing unit, entirely in stainless steel AISI 316 L. Complete with pre-mix modulating gas burner for natural gas or LPG, with NOx emissions in class 5. HUNT HEATING The smart choice. www.huntheat.com.au 5 YEAR* WARRANTY DOUBLE MODULATING PUMP (OPTIONAL) Maximum working pressure: 6 bar High efficiency thanks to the special patented progressive pips in stainless steel Vertical thermal element with low water side pressure losses Vertical burner with integrated check valve, placed above the combustion chamber Retractable standing platform standard supplied (Ares Pro 400 to 600) and optional for other models Control panel is integreted in the panel board Possibility to electronically manage up to 8 boilers (in cascade) Multifunction (SHC) card for control & monitoring of extra heating zones or solar circuits - up to 4 SHC cards can be controlled CONTROL PANEL

Upload: others

Post on 13-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 5 YEAR* CONTROL PANEL WARRANTY€¦ · IMG.V064.04.16.HH IMMERGAS ARES PRO FLOOR STANDING BOILER ARES PRO 150 230 300 400 500 600 Nominal output at 50/30oC min/max kW 36.6 / 146.0

SHOWROOM11 Fiveways BoulevardKeysborough VIC 3173PHONE 1300 00 1800FAX (+613) 9798 5133

[email protected]

IMMERGAS ARES PROFLOOR STANDINGBOILERMANUFACTURED BY:

Large water content condensing unit, entirely in stainless steel AISI 316 L. Complete with pre-mix modulating gas burner for natural gas or LPG, with NOx emissions in class 5.

HUNT HEATINGThe smart choice.

www.huntheat.com.au

5 YEAR*WARRANTY

DOUBLE MODULATING PUMP (OPTIONAL)

• Maximum working pressure: 6 bar

• High efficiency thanks to the special patented progressive pips in stainless steel

• Vertical thermal element with low water side pressure losses

• Vertical burner with integrated check valve, placed above the combustion chamber

• Retractable standing platform standard supplied (Ares Pro 400 to 600) and optional

for other models

• Control panel is integreted in the panel board

• Possibility to electronically manage up to 8 boilers (in cascade)

• Multifunction (SHC) card for control & monitoring of extra heating zones or solar circuits - up to

4 SHC cards can be controlled

CONTROL PANEL

Page 2: 5 YEAR* CONTROL PANEL WARRANTY€¦ · IMG.V064.04.16.HH IMMERGAS ARES PRO FLOOR STANDING BOILER ARES PRO 150 230 300 400 500 600 Nominal output at 50/30oC min/max kW 36.6 / 146.0

IMG

.V06

4.04

.16.

HH

IMMERGAS ARES PRO FLOOR STANDING BOILER

ARES PRO 150 230 300 400 500 600

Nominal output at 50/30oC min/max kW 36.6 / 146.0 54.6 / 226.8 70.0 / 292.7 97.0 / 399.0 124.0 / 472.0 135.0 / 578.0

Nominal output at 80/60oC min/max kW 32.5 / 136.3 48.2 / 209.2 62.0 / 273.7 86.1 / 371.5 110.0 / 440.1 118.5 / 534.5

Efficiency at nom. load at 50/30oC % 104.2 106 104.5 105 105 105

Efficiency at part load at 50/30oC % 104.7 109.2 107.7 107.9 107.8 108.2

Nominal input kW 140 214 280 380 450 550

Max. condensate production kg/h 11.3 13.7 15.8 28.5 28.8 31.0

Modulation ratio 1:4.0 1:4.3 1:4.3 1:4.2 1:3.9 1:4.4

NOx class 5 5 5 5 5 5

CO emissions (at nom. input with 0% of O2) mg/kWh 13 17 17 16 22.7 24.8

NOx emissions (at nom. input with 0% of O2) mg/kWh 34 50 40 29 56 68.4

Water content l 153 210 270 340 340 425

Water pressure in heating circuit min. - max. bar 0.5 - 6 0.5 - 6 0.5 - 6 0.5 - 6 0.5 - 6 0.5 - 6

Max. pressure at the chimney base Pa 100 100 100 100 100 100

* Please contact Hunt Heating for more information.

SIDE VIEW FRONT VIEW SIDE VIEW REAR VIEW ABOVE

ARES PRO

Depth (mm) Width (mm) Height (mm) Net WeightP P1 P2 L L1 L2 L3 H H1 H2 H3 H4 H5 H6 H7

150 944 788 156 666 120 288 81 1809 65.6 1467 323.5 743 571 1579 1679 407

230 1092 954 141 846 120 277 43 1917 65.6 1557 356 775 630 1697 1768 479

300 1181 1036 144 910 100 303 200 1946 65.6 1618 353 790 635 1741 1796 549

400 1276 1152 124 996 100 326 200 2130 65.6 1712 390 820 587 1794 1974 716

500 1276 1152 124 996 100 326 200 2130 65.6 1712 390 820 587 1794 1974 716

600 1398 1256 142 1096 200 388 220 2206 65.6 1753 390 810 763 1863 2052 875

Key:1. Gas pressure switch (SPK 150)

2. Fan3. Insulation of combustion

chamber door4. Combustion chamber5. Panel board HSCP6. Boiler water7. Vertical smoke pipes in

stainless steel with inner aluminium profi les

8. Condensates collecting tray with level sensor

9. Smokes pressure switch

10. Ignition electrode11. Boiler drain cock12. Flame sight glass13. Modulating gas valve14. Burner

G Gas supplyM C.H. fl ow connectionR C.H. return connectionSm Expansion & Safety valve connectionS cond Condensates drain

3

13 2

12

3

14

9

4

7

11

Scond8

10

GSm

M

11

R6

5

1 (mod. 150)

Key:1. Gas pressure switch (SPK 150)

2. Fan3. Insulation of combustion

chamber door4. Combustion chamber5. Panel board HSCP6. Boiler water7. Vertical smoke pipes in

stainless steel with inner aluminium profi les

8. Condensates collecting tray with level sensor

9. Smokes pressure switch

10. Ignition electrode11. Boiler drain cock12. Flame sight glass13. Modulating gas valve14. Burner

G Gas supplyM C.H. fl ow connectionR C.H. return connectionSm Expansion & Safety valve connectionS cond Condensates drain

3

13 2

12

3

14

9

4

7

11

Scond8

10

GSm

M

11

R6

5

1 (mod. 150)

(150)