Continuous Particulate Matter Measurement i QUALITY CUSTOMER SOLUTIONS 4750-PM PM-CEMS DUST MONITOR TUVdotCOM APPROVED TO EN 15267

Upload: others

Post on 21-Aug-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 4750-PM - AMETEK Land...Divyasree N R Enclave,Block A, 4th Floor, Site No 1, EPIP Industrial Area Whitefield, Bangalore- 560066 Karnataka, India Tel: +91 - 80 67823240 Email: land.enquiry@ametek.com

Continuous Particulate Matter Measurementi

Q U A L I T Y C U S T O M E R S O L U T I O N S

4750-PMPM-CEMS DUST MONITORTUVdotCOM APPROVED TO EN 15267

Page 2: 4750-PM - AMETEK Land...Divyasree N R Enclave,Block A, 4th Floor, Site No 1, EPIP Industrial Area Whitefield, Bangalore- 560066 Karnataka, India Tel: +91 - 80 67823240 Email: land.enquiry@ametek.com

4750-PM

4750-PM

THE 4750-PM PROVIDES ACCURATE AND RELIABLE MEASUREMENT OF PARTICULATE MATTER.

The 4750-PM uses an improved back scatter technique to measure particulate matter in stacks and ducts. It features a highly stable optical system resulting in a lower detection limit.

The rugged and reliable design is ideal for applications in electricity generation, industrial boilers, glass, cement and metals. It can be installed after a baghouse or electrostatic precipitator.

AMETEK LAND HAS BEEN MANUFACTURING PRECISION MEASURING EQUIPMENT SINCE 1947. WE ARE SPECIALISTS IN NON-CONTACT TEMPERATURE MEASUREMENT AND COMBUSTION MONITORING WITH APPLICATIONS ACROSS DIVERSE INDUSTRIES SUCH AS STEEL AND GLASS MAKING, POWER GENERATION AND CEMENT MANUFACTURE.

As part of AMETEK Process & Analytical Instruments Division since 2006, our customers benefit from the worldwide AMETEK sales and service team.

F E AT U R E S B E N E F I T S

Large area collection optics Collects scatter from across the stack

Non-intrusive sensor Not affected by flue gas conditions

Wide measurement range Measures concentrations from <1 to 1000 mg/m3

No moving parts Highest stability and reliability

Wide temperature range Standard temperatures up to 250 oC (480 oF)

Zero and span check capability Ensures accurate performance over instrument range

RS485, 4-20 mA outputs Maximum flexibility and connectivity

THE 4750-PM IS A RUGGED, RELIABLE AND VERY ACCURATE DUST MONITOR FOR TYPICAL COMBUSTION APPLICATIONS.

Page 3: 4750-PM - AMETEK Land...Divyasree N R Enclave,Block A, 4th Floor, Site No 1, EPIP Industrial Area Whitefield, Bangalore- 560066 Karnataka, India Tel: +91 - 80 67823240 Email: land.enquiry@ametek.com

W W W. A M E T E K - L A N D . C O M | L A N D . E N Q U I R Y@ A M E T E K . C O M

WIDE TEMPERATURE RANGEThere are no delicate components in the stack, so the 4750-PM can be used in temperatures up to 250 °C (400°F). NO MOVING PARTSThe optical path is pre-set to maximise the measurement across the stack.

CALIBRATION CHECKCheck of zero and upscale calibration capable by inserting pre-defined filters to suit compliance requirements.

• Electricity Generating Units

• Industrial Boilers

• Glass Works

• Cement Plant

• Metals Refining

• Process Heaters

APPLICATIONSTHE 4750-PM CAN BE USED TO MEASURE PM IN ALL COMBUSTION PROCESSES WHERE CONDENSED WATER IS NOT PRESENT

The 4750-PM comprises a stack-mounted sensor with combined internal user interface. All inputs and outputs are connected to the sensor for simple installation and ease of use. Digital and analogue outputs are sent back to the data acquisition system directly as required. Remote triggering of calibration and purge fail sensor are additional options as is a flue gas protector (maybe required when instrument is opened for manual audit and maintenance) to protect operator.

INSTRUMENT DESIGN

TEMPERATURES UP TO 250 oC (400 oF)

SPECIFICATION & DESIGN

BACK SCATTERAs particles travel through the laser beam, they scatter light in all directions. Back scattered light is collected on a detector with stray light eliminated by the inherent instrument design.

CALIBRATION AUDITFilter audit units allow for periodic linearity checks to ensure compliance to international and national emission monitoring standards.

PM-CEMSThe 4750-PM can be used as a continuous emissions monitor (PM-CEMS) for compliance or process monitoring.

Page 4: 4750-PM - AMETEK Land...Divyasree N R Enclave,Block A, 4th Floor, Site No 1, EPIP Industrial Area Whitefield, Bangalore- 560066 Karnataka, India Tel: +91 - 80 67823240 Email: land.enquiry@ametek.com

SPECIFICATIONS

DISCOVER HOW OUR BROAD RANGE OF NON-CONTACT TEMPERATURE

MEASUREMENT AND COMBUSTION & EMISSIONS PRODUCTS OFFER A SOLUTION FOR YOUR PROCESS

WWW.AMETEK-LAND.COM

4750-PMDUST MONITOR

Measuring Probe

Measuring Technique: Back-scatter Optical Detection

Light Source: Diode Laser 650 nm. Class 3R

Measurement Range: 1000 mg / m3

Detection Limit: < 1 mg / m3

Operating Temperature: -20 oC to 50 oC / -4 oF to 122 oF

Max. Flue Gas Temperature: 250 oC (480 oF)

Stack Mounting Flange: DN80 PN10/16 or 3 in. 150 lb ANSI

Materials: Enclosure: Powder-coated aluminium

Air Purge: 30 - 40 litre/minute (1.05 to 1.41 cfm)

Sealing: IP65

Power Supply: 100 to 230 V ac

4-20 mA Outputs: 1

Outputs: 1x RS485 Modbus

Inputs: 1 x digital input

Size (H x W x D): H 216 x W 199 x L 354

Options: Manual audit filter kits

Purge Air: Purge fail sensor and alarm

Blower: Purge blower and blower cover

Flue Gas Protection: Flue gas blocker

Approvals: EN 15267 certified by TUVdotCOM

SEE OUR OTHER DUST AND OPACITY RELATED LITERATURE:

QAL 1 • PS-1 • ASTM D6216 • PROCEDURE 3 • PS-11i

2

SPECIFICATIONS

DISCOVER HOW OUR BROAD RANGE OF NON-CONTACT TEMPERATURE

MEASUREMENT AND COMBUSTION & EMISSIONS PRODUCTS OFFER A SOLUTION FOR YOUR PROCESS

WWW.LANDINST.COM | WWW.AMETEK.COM

For a full list of international offices, please visit our website www.landinst.com Copyright © 2008-16 LAND Instruments International. Continuous product development may make it necessary to change these details without notice. MARCOM0373 4500MkIII Rev 4

Q U A L I T Y C U S T O M E R S O L U T I O N S

4500MkIIICOMPLIANCE OPACITY AND DUST MONITORING

4500MkIIICOMPLIANCE OPACITY AND DUST MONITORING

Measuring Technique: Double pass transmissometry

Operating Wavelength: 520 ± 20 nm

Light Source: Pulsed High Intensity LED

Measurement Range: Opacity 0-10 % to 0-100 % ; Optical Density 0 - 0.1 to 0-3.0 ; Dust Density 0-10 to 0-10000 mg/m3 ; User Selectable

Calibration Error: 1.5 % opacity

Drift (long term): < 0.3 % opacity / month

Thermal Stability: 0.6 % opacity / 22 o C ambient change

Angle of Projection: < 2 o

Angle of View: < 2 o

Response Time: ≤10 s to 95 %

Averaging: Selectable from 10 s to 24 hr (1 s increment)

Pathlength: 0.5 to 10 m / 20 in to 32 ft (extended pathlengths to 15 m available)

Calibration: Automatic zero and upscale check (selectable period 1 to 24 hr in 1 hr increments)

Zero Correction: Automatic correction for zero drift

Control Panel Display: 128 x 64 pixel relective backlit LCD

Control Panel Keypad: 4 keys for data input

Control Panel Indicators: Power, System OK, Alarm, Calibration

Operating Temperature: -40 to 55 o C / -40 to 131 o F

Max. Flue Gas Temperature: 600 o C / 1112 o F

Max. Flange Temperature: 200 o C / 392 o F

Electrical Safety: IEC / EN 61010-2

EMC: EN 50 081 & EN50 082

Sealing: IP65 / NEMA4X

Modbus Interface: RS485; Opacity, Optical Density, Dust Density and Status information available

Analog Outputs: Isolated 4 to 20 mA Configurable as Opacity, Optical Density, Dust Density

Relay Outputs: System OK, Calibration, Alarm

Relay Rating: 1 A @ 24 Vdc

Power Supply: 24 Vdc nominal (18 to 30 Vdc), 0.3 A nominal (3 A startup)

Transceiver Dimensions (HxWxD): 191 x 291 x 413 mm / 7.5 x 7.9 x 16.3 in

Retro-reflector Dimensions (HxWxD): 101 x 201 x 237 mm / 7.5 x 7.9 x 9.3 in

Transceiver Weight: 6 kg / 13.2 lbs.

Retro-reflector Weight: 3 kg / 6.6 lbs.

Enclosure: Cast Aluminum, epoxy coated

Accessories: Fail-safe Shutters, Blowers, Adapter Flanges, Remote Control Units, Additional Outputs Available

Approvals: QAL 1, EN 15267, EN 13284-2

Performance Specifications: ASTM D6216, US EPA PS-1, PS-11, Procedure 3

SEE OUR OTHER PARTICULATE MONITORING AND OPACITY RELATED LITERATURE:

MODEL 4650-PM

PARTICULATE MONITORING

Opacity • Optical Density • Dust Densityi

Q U A L I T Y C U S T O M E R S O L U T I O N S

4200+OPACITY MONITORING

MODEL 4200+

OPACITY MONITORING

Land Instruments InternationalStubley Lane, Dronfield S18 1DJ United Kingdom

Tel: +44 (0) 1246 417691Email: [email protected]

www.landinst.com

AMETEK Land China Service Part A1 & A4, 2nd Floor Bldg. 1 No. 526 Fute 3rd Road East, Pilot Free Trade Zone 200131 Shanghai, China

Tel: +86 21 5868 5111 ext 122 Email: [email protected]

www.landinst.com

AMETEK Land - Americas 150 Freeport Road, Pittsburgh, Pennsylvania, 15238 United States of America

Tel: +1 (412) 826 4444Email: [email protected]

www.ametek-land.com

Applies in the UK Applies in the Us Applies in indiA

Certificate No. C1200

AMETEK Land India Service Divyasree N R Enclave,Block A, 4th Floor, Site No 1, EPIP Industrial Area Whitefield, Bangalore- 560066 Karnataka, India

Tel: +91 - 80 67823240 Email: [email protected]

www.landinst.com

4500MkIII

COMPLIANCE DUST AND OPACITY MONITOR

Opacity • Optical Density • Dust Concentrationi

Q U A L I T Y C U S T O M E R S O L U T I O N S

4400OPACITY AND DUST MONITORING

4400

DUST AND OPACITY MONITORING

We will deliver this by:• Proactively maintaining your equipment to

maximize availability.• Optimizing solutions to meet your unique

applications.• Enhancing user skills by providing access to

product and application experts.

AMETEK Land’s global service network provides unparalleled after-sales services to ensure you get the best performance and value from your AMETEK Land products. Our dedicated service centre teams and on-site engineers are trained to deliver the highest standard of commissioning, maintenance and after-sales support.

AMETEK Land’s AMECare Performance Services ensure peak performance and maximum return on investment over the life of your equipment.

MARCOM0518 4750 PM Rev 3 Copyright © 2008-19 LAND Instruments International. Continuous product development may make it necessary to change these details without notice.

Applies in the UsApplies in indiA

Certificate No. CC-2041

Applies in the UK

www.ametek-land.com

[email protected]

CONTACT US