46832en-01 ds7400xiv4 control panel - bosch security and...

4
Intrusion Systems | DS7400XiV4 Control Panels Security you can rely on. Intrusion Systems | Preliminary DS7400XiV4 Control Panels 46832en-01 DS7400XiV4 Control Panels up to 248 zones in up to eight areas 400-event history buffer up to 200 personal ID numbers (PINs) up to 112 wireless devices up to 15 keypads and/or door access control modules (DACMs) up to 240 addressable points including up to 60 outputs Ethernet network connectivity audio and video alarm verification options remote programming over serial interface, Ethernet network, or phoneline The DS7400XiV4 can be programmed for up to 248 zones in up to eight areas and accepts up to 200 personal ID numbers (PINs).

Upload: others

Post on 09-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 46832en-01 DS7400XiV4 Control Panel - Bosch Security and ...resource.boschsecurity.com/documents/Data_sheet_enUS_25111956… · Bosch Security Systems For more information please

Intrusion Systems | DS7400XiV4 Control Panels

Security you can rely on.

Intrusion Systems |

Preliminary DS7400XiV4 Control Panels

46832en-01DS7400XiV4 Control Panels

• up to 248 zones in up to eight areas

• 400-event history buffer• up to 200 personal ID numbers

(PINs)• up to 112 wireless devices• up to 15 keypads and/or door

access control modules (DACMs)• up to 240 addressable points

including up to 60 outputs• Ethernet network connectivity• audio and video alarm verification

options• remote programming over serial

interface, Ethernet network, or phoneline

The DS7400XiV4 can be programmed for up to 248 zones in

up to eight areas and accepts up to 200 personal ID numbers

(PINs).

Page 2: 46832en-01 DS7400XiV4 Control Panel - Bosch Security and ...resource.boschsecurity.com/documents/Data_sheet_enUS_25111956… · Bosch Security Systems For more information please

2 | DS7400XiV4 Control Panels

System Overview 1. At least one keypad must be connected to the keypad bus and designated as keypad #1. A total of ten keypads (#1 through #10) can be connected to the keypad bus or up to eight DACMs (Door Access Control Modules) can be connected to the keypad bus. Each DACM replaces an available keypad.

2. Up to 30 DS7432E 8-Input Remote Modules can be connected to the DS7430 or DS7436. This allows addressing up to 240 input loops of conventional contacts to the control panel.

3. Up to five keypads (#11 through #15) can be connected to the options bus. DACMs can not be connected to the options bus.

Functions

Addressable bus outputsThe DS7400XiV4 supports up to 240 addressable points. These points can be any combination of:• multiplex addressable devices,• expansion modules with one, two, or eight inputs, or• up to sixty input/output modules.These devices are wired to the addressable bus and provide connectivity to conventional detectors. Up to 112 addressable points can be realized with wireless intrusion or fire devices through two optional RF premises receivers.

History bufferA 400-event history buffer keeps track of system vents and messages (such as open and close events, alarm and trouble messages) by date and time. The buffer can be read at the LCD keypad or retrieved by the RPS Remote Programming Software.

Personal ID numbers (PINs)The system supports up to 200 PINs which can be either four or six digits in length. Any number of PINs can be designated as master PINs; these are the only PINs that can be used to reprogram PINs. All PINs other than PIN#1 may be programmed with up to seven different authority levels. These PINs may be restricted from bypassing, testing, and disarming the system.

DS7445i

DS7447E

DS7445V2

DS7447V2

DS7400XiV4

DS7400X

i

+ – + –

Power Bus

DS7430

– + – –

OptionBus

Battery

Bell Output

AuxiliaryOutput

Poin

t1

Inp

ut

Cla

ss “A

” Lo

op

+

Ho

use

Lin

e2

Rin

g

Ho

use

Lin

e2

Tip

Telc

oLi

ne

2R

ing

Telc

oLi

ne

2Ti

p

Co

ntr

ol

Ho

use

Tip

Co

ntr

ol

Lin

eTi

p

Co

ntr

ol

Ho

use

Rin

g

Co

ntr

ol

Lin

eR

ing

Telc

oLi

ne

1R

ing

Telc

oLi

ne

1Ti

p

Ho

use

Lin

e1

Rin

g

Ho

use

Lin

e1

Tip

Loo

pPo

wer

+

Cla

ss “A

” Lo

op

+

Cla

ss “A

” Lo

op

Cla

ss “A

” Lo

op

+–

++

+–

+–

G

R

B

1

2

3

4

5

6

7

8

9

10

Y

1 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

R TR T T TR R TR TR

Battery Batter y

DS7420i

DX3010

DACMs

+ – + –1 2 3 4 5 6 7 8POWER BUS

DS7432E

DS7445i DS7447E

DS7447V2DS7445V2

RF3222E

1

1

1

1 32

3

3 3

3

Page 3: 46832en-01 DS7400XiV4 Control Panel - Bosch Security and ...resource.boschsecurity.com/documents/Data_sheet_enUS_25111956… · Bosch Security Systems For more information please

DS7400XiV4 Control Panels | 3

Three contact numbersNote: When using the DX4020 Network Interface

Module, IP addresses are used in place of phone numbers.

The DS7400XiV4 supports two telephone numbers up to 32 digits in length with the possibility of a 3- or 4-digit account code for full single, double, and backup reporting. Each of these two telephone numbers can be individually configured for the type of communication format and choice of pulse or tone dialing. The third telephone number is used for remote programming.

ZonesThe DS7400XiV4 accepts up to 248 zones. These zones can consist of eight hardwired zones, plus the remaining addressable zones. Any of these zones can be programmed to follow one of thirty programmable zone functions.

Parts Included

Each standard system includes:

Certifications and Approvals

Installation/Configuration Notes

Compatible productsThe following products are compatible with the DS7400XiV4 system:

Quant. Component

1 DS7400XIV4 board

1 Universal enclosure

1 Transformer (18 V, 50 VA)

Country Certification/Listing Number

Australia Austel

Belgium BEL

Europe CE

USA AMCX: Central Station Alarm Units (UL1610)

AOTX: Local Alarm Units (UL464)

APAW: Police Station Alarm Units (UL365)

APOU: Proprietary Alarm Units (UL1076)

NBSX: Household Burglar Alarm System Units

(UL1023)

UOJZ: Control Units, System (UL864)

UTOU: Control Units and Accessories –

Household System Type (UL985)

Category Product

Power Supplies DS9484 NAC Power Supply

Keypads DS7445i LED keypad

DS7445V2 LED keypad

DS7447E LCD keypad

DS7447V2 LCD keypad

Detectors MX250 Photoelectric Smoke Detector

MX250TH Photoelectric Smoke Detector with

heat-sensing thermistor

MX775i Addressable PIR Detector (7.2 m)

MX794i Long-Range PIR Detector (61 m)

MX835 Pet Friendly TriTech Detector

MX934i Addressable PIR Detector (11 m)

MX938i Addressable PIR Detector (18 m)

RF Products RF835E Wireless TriTech® Detector

RF940E Wireless PIR Detector

RF1100E RF Glass Break Detector

RF3222E RF Receiver

RF3332E 2-Button Keyfob

RF3334E 4-Button Keyfob

RF3401E RF Transmitter

Modules C900 Dialer Capture Module

DS432 Reversing Relay Module

DS7104 Line Reversal Module

DS7111i Dual Phone Line Module

DS7420i Dual Phone Line/Bell Supervision

Module

DS7430 Multiplex Bus Driver Module

DS7432E 8-Input Remote Module

DS7433E 8-Input Direct Module

DS7436 Addressable Expansion Module

DS7457iE Single-Zone Input Module

DS7460i Double-Input Module

DS7461i Single-Input Module

DS7465i Input/Output Module

DS7480 Bell Supervision Module

DS7481 Single Phone Line Monitor

DS7488 Octal-Relay Module

DX3010 Octo-Output Expander

DX4010i RS-232 Serial Interface Module

DX4020 Network Interface Module

Page 4: 46832en-01 DS7400XiV4 Control Panel - Bosch Security and ...resource.boschsecurity.com/documents/Data_sheet_enUS_25111956… · Bosch Security Systems For more information please

4 | DS7400XiV4 Control Panels

Modifications reserved | Printed in USA | 46832en-01 | Printer | 1/14/05

Bosch Security Systems

For more information please visit

www.boschsecuritysystems.com

Technical Specifications

Preliminary DS7400XiV4 Control Panels

Enclosure Design

Color: Gray

Dimensions (HxWxD): 31.8 cm x 36.8 cm x 7.6 cm

(12.5 in. x 14.5 in. x 3 in.)

Material: 0.9 mm (20 Ga) cold-rolled steel

Environmental

Considerations

Temperature (Operating): 0°C to +49°C (+32°F to +120°F)

Electrostatic Discharge

(ESD) and Lightning

Suppression:

MOVs and spark gaps are provided to

suppress damage due to lightning

strikes and electrostatic discharge.

Outputs

Alarm Output: Normally Open (NO), 1.75 A contact

connected to auxiliary power

Programmable Output 1: Solid state current sink (1 A maximum)

that can be used for alarm, arming

state, or access control

Programmable Output 2: Solid state voltage source (500 mA

maximum) that can be used for alarm

Power Requirements

Input Power: 18 VAC, 50 VA (50 Hz)

Output Power (alarm): 1.75 A

Output Power (total): 12 VDC, 2.5 A

Ordering Information

Hardware AccessoriesAE1 Enclosure AE1

AE2 Enclosure AE2

AE3 Enclosure AE3

AE3CC Attack-Resistant Enclosure AE3CC

AE4 Enclosure AE4

D110 Tamper Switch D110