46 conventional fire menvier fire panels menvier fire panels · 2017. 7. 13. · menvier fire...

12
Menvier Fire Panels MF200 / 400 series Supplied with battery & end of line devices 72 hour standby option (MF400) One man walk test facility Large choice of cable entries Menvier Fire Panels MF9300 series Up to 32 detectors per zone 72 hour standby on standard version One man walk test facility Non-latching zone facility Flush or surface mounting 46 Conventional Fire

Upload: others

Post on 26-Jan-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

  • Menvier FirePanels

    MF200 / 400 series

    Supplied with battery & end of line devices

    72 hour standby option (MF400)

    One man walk test facility

    Large choice of cable entries

    Menvier Fire Panels

    MF9300 series

    Up to 32 detectors per zone

    72 hour standby on standard version

    One man walk test facility

    Non-latching zone facility

    Flush or surface mounting

    46 Conventional Fire

  • CATALOGUE NUMBERS

    W

    H

    D

    W

    H

    D2

    D1

    DIMENSIONS

    Cat No Number Standby Weight

    of Zones Duration (hrs) (kg)

    Menvier MF200 / 400 PanelsMF200 2 24 4.8

    MF400 4 24 4.8

    MF400-72 4 72 6.0

    Menvier MF9300 PanelsMF9302 2 72 10.6

    MF9304 4 72 10.6

    MF9308 8 72 16.8

    MF9316 16 72 16.9

    MF9308-L 8 24 16.0

    MF9316-L 16 24 16.0

    Menvier MF9300 Repeater PanelsMFR9308 8 72 16.8

    MFR9316 16 72 17.2

    Cat No Description

    Optional AccessoriesMAR424 Fire and fault relay PCB

    for MF200/400

    H W D

    (mm) (mm) (mm)

    300 300 74

    H W D1 D2 Cut-out

    (mm) (mm) (mm) (mm) (mm)

    2/4 zone 344 395 25 70 324 x 385

    8/16 zone 386 395 25 119 376 x 385

    Note: If surface mounting, add D1 & D2 to obtain depth dimension

    TECHNICAL SPECIFICATION

    Panel Catalogue No MF200 MF400 MF9302 MF9304 MF9308 MF9316

    Number of Zones 2 4 2 4 8 16

    Detectors Per Zone 20 32

    Number of Alarm Circuits 2 2 4

    Alarm Circuit Load 375mA per circuit. 750mA total 500mA per circuit. 1A total

    End of Line Devices Detection circuits: 22KΩ resistor Detection circuits: 12KΩ resistor

    Alarm lines: 22KΩ resistor Alarm lines: 12KΩ resistor

    Auxiliary Fire Signal Output 24V DC pull to 0V. Max 10mA 1A 24V DC (resistive) single pole change over contacts. Isolate facility available

    Auxiliary Fault Output 24V DC pull to 0V. Max 10mA 1A 24V DC (resistive) single pole changeover contacts

    Auxiliary Common Output 24V DC pull to 0V. Max 10mA

    Auxiliary DC Output 24V DC fused. (up to 100mA 32mA 24V DC fused. 100mA 24V DC fused. 350mA

    at the expense of alarm load)

    Repeater Output 2 wire serial link (Repeater also requires separate 230V AC supply)

    Mains Input Voltage 240V AC +10%-15% 230V AC ±10%. 50/60 Hz

    System Operating Voltage 24V DC

    Standby Duration 24 hours (72 hours on MF400-72) 72 hours (24 hours option on 8 & 16 zone)

    Battery 1 x 4AH sealed lead acid battery 1 x 7AH sealed lead acid battery 1 x 12AH sealed lead acid battery

    (1 x 7AH on MF400-72)

    Recharge Period 48 hours (80% in 24 hours) 24 hours

    Panel Construction ABS/Polycarbonate housing. ABS/Polycarbonate ABS/Polycarbonate

    Steel back box. housing & back box housing & steel back box

    Cable Entries Top: 10 x 20mm knockout Top: 13 x 20mm knockouts Top: 27 x 20mm knockouts Back:

    Bottom: 1 x 20mm knockout back: 1 x 20 mm knockouts back: 1 x 20 mm knockouts

    Back: 1 x mains cable entry slot

    Environmental Rating IP30. -5°C to +40°C. IP20. -5°C to +40°C

    Humidity 75% max (non-condensing) Humidity 75% max (non-condensing)

  • JSB Fire PanelsFX4200 series

    Complies with EN 54

    Supplied with battery & end of line devices

    Simple ‘one shot’ auto reset user test facility

    Programmable fire / fault output relay

    JSB Fire Panels

    FX2200 series

    Approved to EN54

    Supplied with battery & end of line devices

    Choice of 1,2,4 or 8 zones

    Maintenance free polyswitch circuit protection

    Custom configured versions available

    FX2200 BW series

    Quick and simple to install

    Detectors & sounders share same pair of wires

    Choice of 1,2,4 or 8 zones

    Custom configured versions available

    48 Conventional Fire

  • CATALOGUE NUMBERS

    Cat No of Standby Weight

    No Zones Duration (kg)FX4202 2 24 hrs 4.8

    FX4204 4 24 hrs 4.8

    PanelsFX2201 1 24 hrs 5.1

    FX2202 2 24 hrs 5.2

    FX2204 4 24 hrs 5.8

    FX2208 8 24 hrs 6.0

    Panels - configured for use with a repeaterFX2202CR 2 24 hrs 5.8

    FX2204CR 4 24 hrs 6.0

    Repeater PanelFXRP2200 8 24 hrs 6.0

    PanelsFX2201BW 1 24 hrs 5.1

    FX2202BW 2 24 hrs 5.2

    FX2204BW 4 24 hrs 5.8

    FX2208BW 8 24 hrs 6.0

    W

    H

    D

    H W D

    (mm) (mm) (mm)

    300 300 74

    W

    H

    D2

    D1

    1 2 3 4 5

    SCROLLMUTEBUZZER

    Recessed H W D1 D2 Cut-out

    (mm) (mm) (mm) (mm) (mm)

    2/4/8 zone 270 332 45 47 265 x 327

    Surface H W D

    (mm) (mm) (mm)

    1 zone 212 260 72

    2/4/8 zone 270 332 92

    DIMENSIONS

    Panel Catalogue No FX4202 FX4204 FX2201/ FX2202/ FX2204/ FX2208/

    FX2201BW FX2202BW FX2204BW FX2208BW

    Number of Zones 2 4 1 2 4 8

    Detectors per Zone 20

    Number of Alarm Circuits 2 4

    Alarm Circuit Load 150mA per 400mA per 150mA per circuit 500mA per circuit, 2A total,

    circuit 0.3A total circuit 0.8A total 0.3A total 150mA per zone

    End of Line Devices Detection circuits: EOLM-1 monitoring unit Alarm lines: 6.8KΩ resistor

    Auxiliary Fire Signal/Fault Output 5A 24V DC single pole changeover contacts

    Auxiliary DC Output 24V DC fused. 30mA_

    Mains Input Voltage 230V AC -10% +15%

    System Operating Voltage 24V DC

    Standby Duration 24 hours

    Battery (sealed lead acid) 1 x 3.2AH 2 x 3.2AH

    Recharge Period 24 hours

    Panel Construction Polycarbonate housing & back box

    Cable Entries Top: 10x20 mm conduit entries Top: 6x20mm Top: 12x20mm Top: 12x20mm

    Bottom: 10x20 mm conduit entries entries with entries with entries with

    Back: 1x mains cable entry slot blanking plugs blanking plugs blanking plugs

    Rear cable Rear cable Rear cable

    entry aperture entry aperture entry aperture

    Environmental Rating IP30. -5°C to +40°

    Humidity 75% max (non-condensing)

    TECHNICAL SPECIFICATION

    FX2200

    FX4200

  • ConventionalDetectors and

    BasesJSB and Menvier Detectors

    LPCB approved

    Drift Compensation

    Ultra low profile, 360° viewing angle LED

    Photo thermal alternative to old ionisation types

    Conventional Detectorsand Bases

    Self Test Detectors

    Constantly checks and confirms detector operation

    Triggers fault locally and at panel in event of fault

    Drift compensation

    New patented technology

    Enhanced integrity for conventional systems

    Detector Bases

    Selectable detector locking feature

    Separate loop in and out connections

    Base incorporates features to supportsurface wiring

    50 Conventional Fire

  • CATALOGUE NUMBERS

    Description Cat No to suit Cat No to suit Cat No to suit

    Menvier systems JSB systems JSB Bi wire systems

    Enhanced optical smoke detector MPD821 FXN533 FXN623

    Enhanced photo thermal detector MPT951 FXN632 FXN622

    Fixed heat detector (77°C) MMT860 FXN524 FXN624

    Fixed heat detector (92°C) MHT890 FXN526 FXN626

    Rate of rise heat detector MFR830 FXN525 FXN625

    Common base MDB800 FXN520 FXN520

    Cat No Description

    FXN523ISC JSB Self Check optical conventional detector

    FXN524ISC JSB Self Check conventional heat detector (77°C)

    FXN525ISC JSB Self Check conventional heat detector (Rate of rise)

    FXN526ISC JSB Self Check conventional heat detector (92°C)

    FXN622ISC JSB Self Check combined photo/thermal conventional detector

    FXN520 JSB common mounting base

    Dia D (excluding base) D (including base)

    (mm) (mm) (mm)

    Optical smoke detectors 101 33 45

    Photo-thermal detector 101 43 55

    Heat detectors 101 43 55

    DIMENSIONS

    Dia

    D

  • ConventionalSounders

    Conventional Sounders

    Speech • 100dB(A) output• Clear intelligible human speech

    Flush Electronic • Low profile design• Volume control

    Ceiling Mounted • Reduced install time• Optional blanking plate when

    used without a detector

    Staff Warning • Discrete audible and visual alarm

    • Twin high intensity LED’s

    Surface Low • Choice of colourProfile • 32 selectable tones

    Surface • Weatherproof designWeatherproof • Choice of cable entry

    High Output • Ideal for areas with highambient noise

    Low Current • High efficiency design

    52 Conventional Fire

  • CATALOGUE NUMBERS

    Cat No Description Message Version Weight (kg)

    MSS7MR 24V Menvier speech sounder (red) A 0.3

    MSS20MR 24V Menvier speech sounder (red) B 0.3

    MSS28MR 24V Menvier speech sounder (red) C 0.3

    MSS7MW 24V Menvier speech sounder (white) A 0.3

    MSS20MW 24V Menvier speech sounder (white) B 0.3

    MSS28MW 24V Menvier speech sounder (white) C 0.3

    Dia D

    (mm) (mm)95 105

    Cat No Description Weight (kg)

    MFS324 Menvier red flush sounder 0.3

    MFS324W Menvier white flush sounder 0.3

    FX003 JSB flush sounder (red) 0.3

    H W D

    (mm) (mm) (mm)86 86 36

    Cat No Description Weight (kg)

    MDS824 Menvier detector base sounder 0.4

    MDS824B Menvier detector base sounder beacon 0.4

    MDS824COV Blanking plate 0.1

    Dia D

    (mm) (mm)111 26

    Cat No Description Weight (kg)

    MAS175 Staff warning device 0.24

    H W D

    (mm) (mm) (mm)89 150 58

    Cat No Description Weight (kg)

    MWS424SB Menvier low profile surface sounder (red) 0.24

    FX002 JSB low profile surface sounder (red) 0.24

    FX002W JSB low profile sounder (white) 0.24

    Dia D

    (mm) (mm)93 63

    Cat No Description Weight (kg)

    MWS424DB Menvier weatherproof surface sounder (red) 0.3

    Dia D

    (mm) (mm)93 93

    Cat No Description Weight (kg)

    FX007 JSB high output conventional sounder (red) 0.28

    H W D

    (mm) (mm) (mm)105 105 95

    Cat No Description Weight (kg)

    MLC624 Menvier low current conventional sounder (red) 0.25

    H W D

    (mm) (mm) (mm)105 105 95

    DIMENSIONS

    Dia

    D

    Dia

    D

    H

    W

    Dia

    D

    D

    H

    W

    D

    Dia

    D

    D

    W

    H

    H

    W

    D

  • ConventionalFire Beacons

    Conventional FireBeacons

    Xenon

    High light output

    Weatherproof version supports side entrysurface cables

    Unobtrusive low profile design

    Xenon Sounder

    Sounder & Beacon with a single installation point

    Weatherproof version IP65

    LED

    Low profile consumption

    Discrete low profile design

    Choice of Flashing frequency

    LED Sounder

    Sounder & Beacon with a single installation point

    Choice of cable entries

    Weatherproof version

    54 Conventional Fire

  • Lamp L W D Lamp L W DRating (mm) (mm) (mm) Rating (mm) (mm) (mm)

    T8/12 lamps1x18W 627 58 92 2x18W 627 89 921x36W 1238 58 92 2x36W 1238 89 921x58W 1538 58 92 2x58W 1538 89 921x70W 1802 58 92 2x70W 1802 89 921x100W 2413 58 92 2x100W 2413 89 92T5 lamps1x14/24W 627 58 80 2x14/24W 627 58 801x28/54W 1238 58 80 2x28/54W 1238 58 801x35/49W 1538 58 80 2x35/49W 1538 58 80

    R

    R

    R

    R

    R

    R

    CATALOGUE NUMBERS

    Cat No Description

    MXB124SB Menvier low profile Xenon beacon (red lens)

    FX004R JSB low profile Xenon beacon (red lens)

    FX004A JSB low profile Xenon beacon (amber lens)

    FX004B JSB low profile Xenon beacon (blue lens)

    CATALOGUE NUMBERS DIMENSIONS

    Dia D

    (mm) (mm)93 72

    Cat No Description

    MXB124DB Menvier low profile Xenon beacon

    Cat No Description

    MCD524SB Menvier low profile combined sounder beacon (red lens)

    FX002CR JSB low profile combined sounder beacon (red lens)

    FX00 2CA JSB low profile combined sounder beacon (amber lens)

    FX002CB JSB low profile combined sounder beacon (blue lens)

    Dia D

    (mm) (mm)93 92

    Cat No Description

    MCD524DB Menvier weatherproof sounder beacon

    Dia D

    (mm) (mm)93 121

    Cat No Description

    MLB124SB Menvier low profile LED beacon

    FXN004BW Bi wire LED beacon

    Dia D

    (mm) (mm)95 53

    Cat No Description

    MLB124DB Menvier weatherproof LED beacon

    Dia D

    (mm) (mm)95 80

    Cat No Description

    MSB124SB Menvier low profile LED sounder beacon

    Dia D

    (mm) (mm)93 80

    Cat No Description

    MSB124DB Menvier weatherproof combined LED sounder beacon

    Dia D

    (mm) (mm)95 109

    Dia D

    (mm) (mm)93 101

    D

    Dia

    Dia

    D

    Dia

    D

    Dia

    D

    Dia

    D

    Dia

    D

    Dia

    D

    Dia

    D

  • ConventionalFire Ancillaries

    Conventional FireAncillaries

    Bells

    High sound output

    Low current consumption

    Weatherproof version

    Call Points

    Fast fit clip on front cover

    Heavy duty terminals

    Weatherproof version

    Door Retainers and Relays

    Mains and 24V versions

    Manual release facility

    Optional Floor bracket

    56 Conventional Fire

  • CATALOGUE NUMBERS DIMENSIONS

    Cat No Description

    MBM244 100mm Metal bell (Menvier)

    MBM246 150mm Metal bell (Menvier)

    MBM248 200mm Metal bell (Menvier)

    FX006 150mm Metal bell (JSB)

    Cat No Description

    MWB824 200mm Weatherproof metal bell

    Dia D

    (mm) (mm)200 104

    Cat Dia D

    No (mm) (mm)

    MBM244 100 63

    MBM246 152 63

    MBM248 203 63

    FX006 152 63

    Cat No Description

    MBG914 Surface callpoint to suit Menvier systems

    MBG913 Flush callpoint to suit Menvier systems

    MBG917 Weatherproof surface callpoint to suit Menvier systems

    MBG914L Surface callpoint c/w LED to suit Menvier systems

    MBG917L Weatherproof surface callpoint c/w LED

    FX201 Surface callpoint to suit JSB conventional systems

    FX201L Surface callpoint c/w LED to suit JSB systems

    FX203 Weatherproof surface callpoint to suit JSB systems

    FX203L Weatherproof surface callpoint c/w LED

    W D H

    Description (mm) (mm) (mm)

    Flush callpoint 87 36 87

    Surface callpoint 87 57 87

    Weatherproof callpoint 108 70 108

    Cat No Description

    FX021240LC Compact magnetic door retainer (mains powered)

    FX02124VLC Compact magnetic door retainer (24V DC powered)

    FX021LCFB Floor mounting bracket for compact door retainer

    H W D

    Description (mm) (mm) (mm)

    Magnet 71 108 44

    Sticker plate 65 65 48

    Cat No Description

    MDR240 Heavy duty magnetic door retainer (mains powered)

    MDR24L Heavy duty magnetic door retainer (24V DC powered)

    ZMDRFBB Floor mounting bracket for heavy duty door retainer

    H W D

    Description (mm) (mm) (mm)

    Magnet 95 95 40

    Sticker plate 65 65 48

    Cat No Description

    MAR724 Heavy duty relay

    W H D

    (mm) (mm) (mm)150 89 58

    Cat No Description

    FX251D Remote indicator unit

    W H D

    (mm) (mm) (mm)87 87 30

    H

    D

    Dia

    Dia

    D

    W W

    H

    D D

    HH

    WW

    DD

    WW

    HH

    D

    D

    W

    H

    D

    W

    H

    D