40155690-ekotoksikologi-lethal-concentration-50

31
LC 50 (Lethal Concentration) SEBUAH PENDEKATAN DALAM UJI TOKSISITAS KUANTITATIF Faculty of Fisheries and Marine Sciences University of Padjadjaran 2009 UJI TOKSISITAS KUANTITATIF (Part 2) MODULE :

Upload: bagifile

Post on 24-Nov-2014

105 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: 40155690-Ekotoksikologi-Lethal-Concentration-50

LC50 (Lethal Concentration) SEBUAH PENDEKATAN DALAM

UJI TOKSISITAS KUANTITATIF

Faculty of Fisheries and Marine SciencesUniversity of Padjadjaran

2009

UJI TOKSISITAS KUANTITATIF (Part 2)

MODULE :

Page 2: 40155690-Ekotoksikologi-Lethal-Concentration-50

Checked

Substance Quantities (Amount)

Substance Properties

Substance Characteristics

Organisms Tolerance (Bio assay)

Page 3: 40155690-Ekotoksikologi-Lethal-Concentration-50

LC stands for "Lethal Concentration". LC values usually refer to the concentration of a chemical in air but in environmental studies it can also mean the concentration of a chemical in water (Canadian Centre for Occupational Health and Safety/ CCOHS 2005)

Suatu bahan kimia dinyatakan berkemampuan toksik akut bila aksi langsungnya mampu membunuh 50% atau lebih populasi uji dalam selang waktu yang pendek, misal 24 jam, 48 jam s/d 14 hari (Meyer et.al. 1982)

What does LC50 mean?

Page 4: 40155690-Ekotoksikologi-Lethal-Concentration-50

Why LC50?

Concentration (or Dose)

Res

pon

se

Low High

0%

100%

Page 5: 40155690-Ekotoksikologi-Lethal-Concentration-50

Preparation for Conducting LC50 Test

1. Organisme Uji Artemia, Dhapnia : Acute Test Ikan Mas, Udang : Acute, Sub-Lethal

2. Konsentrasi Uji (I,ii,ii µg/mL)

3. Format Tabulasi Data dan Analisis Probit

- Tabel Data Kelompok

- Tabel Data Kelas

- Tabel Rekap Probit

Page 6: 40155690-Ekotoksikologi-Lethal-Concentration-50

Preparation of Toxicity Test Organisms

Use of test species based on :– Lab hardiness– Common– Known life cycle– Cheap– Short-lived

1

Page 7: 40155690-Ekotoksikologi-Lethal-Concentration-50

Use an aquarium for fish or shrimp

Use a vial glass bottle for Dhapnia or Brine Shrimp

Page 8: 40155690-Ekotoksikologi-Lethal-Concentration-50

2

Run a dilution series of Toxicant

Test Material (toxicant) conditions : • Pure• Commercial formulation• Mixtures of known concentration• Carriers/solvents• Unknown mixtures (eg. sediment, effluent)

And it must be served in variation of concentration (or Dose)

Page 9: 40155690-Ekotoksikologi-Lethal-Concentration-50

PA PS H

Original Concentration

1000 µg/mL

V1.N1 = V2.N2x.1000 = 100.100

Diambil 10 mL+ 90 mL medium

Larutan Stock @ 100 µg/mL sebanyak 100 mL

PA PS H

Preparation of Stock Solution

Page 10: 40155690-Ekotoksikologi-Lethal-Concentration-50

10 -1

10 -2

10 -3

Larutan Stock

100 µg/mL

10 µg/mL

1 µg/mL

0,1 µgL

Diambil 1 mL+ 9 mL medium

Diambil 1 mL+ 9 mL medium

Diambil 1 mL+ 9 mL medium

V1.N1 = V2.N2x.100 = 10.10

V1.N1 = V2.N2x.10 = 10.1

V1.N1 = V2.N2x.1 10. (0,1)

Preparation of Dilution Series

Page 11: 40155690-Ekotoksikologi-Lethal-Concentration-50

Dilution series of Toxicant

10 -210 -1 10 -3Toxicity Test Organisms

1. Static Test2. Renewable Test3. Resirculation Test4. Flow-Trough Test

Observe Mortality for Determine LC50

Expose to The Test Medium

Page 12: 40155690-Ekotoksikologi-Lethal-Concentration-50

Metode Hubert (1979)

Probit = probability unit

% of population responding as a function of standard deviation units from the mean

Nilai Probit dari persentase mortalitas hewan uji merupakan fungsi linear : Y = a + bx

3 Determine LC50 Using Probit Analysis

1

Page 13: 40155690-Ekotoksikologi-Lethal-Concentration-50

Nilai LC50 diperoleh dari anti log m(m merupakan logaritma konsentrasi klorin pada Y = 5/ nilai Probit 50% hewan uji)

m = 5 – ab ……………………. (1)

b = ∑ XY – 1/ n (∑ X ∑Y) ∑ X2 – 1/ n (∑ X)2 ……………………. (2)

a = 1/ n (∑Y – b ∑ X) ……………………..(3)

Page 14: 40155690-Ekotoksikologi-Lethal-Concentration-50

Normal distribution of resistance/sensitivityF

requ

ency

5% allowable impact

0

100

Mean response

Protected

Page 15: 40155690-Ekotoksikologi-Lethal-Concentration-50

Preparing Data Tabulation

Format Tabulasi Data Analisis Probit LC50

Jenis Hewan Uji :………………………………………Jenis Bahan Toksik :………………………………………

d (Konsentrasi

Uji)

n (jumlah

hewan uji)

r (Mortalitas hewan uji)

p(%Mortalitas)

X (Log

Konsentrasi)

Y (Nilai Probit %

Mortalitas)

XY

i 30

ii 30

iii 30

Jumlah ( ∑ ) ∑ X ∑Y ∑XY

Lihat di Tabel Probit % Mortalitas

Page 16: 40155690-Ekotoksikologi-Lethal-Concentration-50

Log Probit

6.181.009

6.18

1.009

Page 17: 40155690-Ekotoksikologi-Lethal-Concentration-50

b = …………………….. Persamaan (2)

a = ……………………. Persamaan (3)

m = ……………………. Persamaan (1)

Determine a,b and m value to determine LC50 value

LC50 = anti Log m = ………………… ppm

Page 18: 40155690-Ekotoksikologi-Lethal-Concentration-50

Tolerance

Dose-Response

No.

of

Ind

ivid

ual

s

No.

of

Ind

ivid

ual

s

Cu

mul

ativ

e P

erce

nt

Cu

mul

ativ

e P

erce

nt

Log of Concentration

Log of Concentration

Concentration

Concentration

Page 19: 40155690-Ekotoksikologi-Lethal-Concentration-50

In Probit Analysis we cannot measure normal distribution directly because effect is cumulative, so graph as cumulative distribution

Log Dose

Cumulative distribution

Dose

# R

espo

ndin

g

Normal distribution

Page 20: 40155690-Ekotoksikologi-Lethal-Concentration-50

2 Metode Matsumura (1985)

Log LC84= 0.93; LC84= 8.51

Log LC16 = 0.43; LC16 = 2.69

Log LC50 = 0.68; LC50 = 4.79

“ Determination Inverse Prediction”

Page 21: 40155690-Ekotoksikologi-Lethal-Concentration-50

Calculating 95% Confidence Limits of LC50's(source: F. Matsumura. 1985. Toxicology of Insecticides, 2nd Ed., Plenum, pp.14-16)Example Worksheet - Rotenone toxicity to Macrosphoniella sanborni

1. Use inverse prediction from the graph to estimate the Log 10 of the LC84, LC16, and LC50 then “un-log” the values and express as mg/L.

Log10 Conc. Conc. (mg/L)eg: LC84 = LC16 =

LC50 =

2. Calculate S and Log10 (S) (use the 'un-logged' dose/conc. values).

LC84 LC50 S = LC50 LC16

2S = Log10 (S) =

+

.93 8.51.43 2.69.68 4.79

+8.514.79

4.792.69

2

=

1.78 0.250

Page 22: 40155690-Ekotoksikologi-Lethal-Concentration-50

3. Determine NN = the total number of individuals tested between the range of dosages that correspond to the LC16 to the LC84.

N =

4. Calculate Log10(f) and f. 2.77Log10(f) = N x Log10 (S)

Log10(f) = f =

5. Calculate Upper and Lower 95% Confidence Limits (multiply or divide 'unlogged' conc/dose values by f):

Upper Limit = LC50 x f =Lower Limit = LC50 / f =

=

LC50 = 4.79 mg/L (4.19 – 5.47; 95% C.L.)

49 + 46 + 48 = 143

2.77 x 0.250

143

0.058

4.79 x 1.143 = 5.47

4.79 / 1.143 = 4.19

1.143

Page 23: 40155690-Ekotoksikologi-Lethal-Concentration-50
Page 24: 40155690-Ekotoksikologi-Lethal-Concentration-50

Log scale

Page 25: 40155690-Ekotoksikologi-Lethal-Concentration-50

3 Validasi dengan Program Probit

Program Komputasi Perhitungan Nilai Probit :

1. EPA Probit Versi 1.5

2. Micro Probit 3.0

Page 26: 40155690-Ekotoksikologi-Lethal-Concentration-50

EPA Probit Version 1.5

Case Sample : Data Mortalitas Larva Udang Windu Setelah Pemaparan 96 jam pada Logam Cu

d (konsentrasi uji, ppm) n (jumlah hewan uji) r (mortalitas hewan uji)

0 (Kontrol) 30 0

0.251 30 0

0.63 30 3

1.58 30 13

3.97 30 19

9.96 30 30

Berapa LC50-96 jam ?

Page 27: 40155690-Ekotoksikologi-Lethal-Concentration-50

EPA PROBIT ANALYSIS PROGRAMUSED FOR CALCULATING LC/EC VALUES

Version 1.5

LC_Cu_UdangWindu Proportion Observed Responding Predicted Number Number Proportion Adjusted for Proportion Conc. Exposed Resp. Responding Controls Responding 0.2510 30 0 0.0000 0.0000 0.0083 0.6300 30 3 0.1000 0.1000 0.0859 1.5800 30 13 0.4333 0.4333 0.3674 3.9700 30 19 0.6333 0.6333 0.7553 9.9600 30 30 1.0000 1.0000 0.9572 Chi - Square for Heterogeneity (calculated) = 4.643Chi - Square for Heterogeneity (tabular value at 0.05 level) = 7.815 Mu = 0.330260Sigma = 0.388480 Parameter Estimate Std. Err. 95% Confidence Limits---------------------------------------------------------------------Intercept 4.149867 0.176426 ( 3.804072, 4.495663)Slope 2.574135 0.344351 ( 1.899208, 3.249063) Theoretical Spontaneous Response Rate = 0.0000

EPA Probit Analysis Report (Out put)

Page 28: 40155690-Ekotoksikologi-Lethal-Concentration-50

LC_Cu_UdangWindu Estimated LC/EC Values and Confidence Limits Exposure 95% Confidence LimitsPoint Conc. Lower Upper LC/EC 1.00 0.267 0.122 0.431LC/EC 5.00 0.491 0.274 0.712LC/EC 10.00 0.680 0.419 0.936LC/EC 15.00 0.847 0.555 1.132LC/EC 50.00 2.139 1.665 2.762LC/EC 85.00 5.406 4.007 8.407LC/EC 90.00 6.732 4.837 11.154LC/EC 95.00 9.317 6.355 17.060LC/EC 99.00 17.139 10.490 38.270

EPA Probit Analysis Report (Out put)

LC50 Value

Page 29: 40155690-Ekotoksikologi-Lethal-Concentration-50

LC_Cu_UdangWindu PLOT OF ADJUSTED PROBITS AND PREDICTED REGRESSION LINE Probit- 7+ . - .. - .. - ... - .... 6+ .... - .... - ... - .... o - .... 5+ ... - o.... - .... - ... - .... 4+ .... - o.... - ... - .. - .. 3+ . - -. - - 2+ - - - - 1+ -+--------------+--------+---------+---------+--------+--------------+- EC01 EC10 EC25 EC50 EC75 EC90 EC99

EPA Probit Analysis Report (Out put)

Page 30: 40155690-Ekotoksikologi-Lethal-Concentration-50

Take Home Task!

Determine LC50-96hr Value from the Case Sample using Manual Probit Analysis Hubert (1979) Metodh!

And please attach also EPA Probit V 1.5 Report (Out put sheet) as validation

Deadline : Nov 5, 2009

Page 31: 40155690-Ekotoksikologi-Lethal-Concentration-50

Photo by R. Grippo

If there is magic on earth, it is in water

Thank you