Sanken General Purpose Inverter
400 V class : IHF 1.5kW~250kWIPF 7.5kW~315kW
Sanken General Purpose Inverter
SAMCO-i SERIES
Upgraded Functions and Performance!
Optimum Model Selection Reduces Costs
1
•Optimum Model SelectionTwo models are availabe to withstand different overloads. The allowable overload capacity is 150%for the IHF model and 120% for the IPF model. Select the IHF model for quick acceleration ordeceleration and the IPF model for greater motor output.
•Sensorless Vector ControlIn addition to V/f control, the SAMCO-i general purpose inverter supports sensor-less control toenhance speed control and load responsiveness. Even when the inverter is used with a non-standard motor, the auto tuning function automatically measures the motor constants necessary forSensorless Vector Control and controls the speed accordingly.
•Energy-Saving ControlThe SAMCO-i general purpose inverter operates in three energy-saving modes. Selecting theoptimum mode greatly reduces energy consumption.
•High-Grade Flying Start Function(with a Revolution Direction Detection Function)The conventional inverter sometimes tripped the motor due to an overcurrent in a sudden free-runstart. However, the SAMCO-i general purpose inverter provides a smooth start by detecting therevolution speed and direction of the motor. For example, the general purpose inverter can stop themotor of a fan without shock for a smooth flying start in a specified direction even when a headwindis turning the motor in the reverse direction.
•PID FunctionThe standard PID function simplifies system design.
•Momentary Voltage Drop Compensation FunctionIn case of a momentary voltage drop or power failure, the momentary voltage drop compensationfunction allows a motor to run continuously with minimum tripping by using the inertia of the motoror load.
•Good Acceleration/Deceleration CharacteristicsThe DSAMCO-i general purpose inverter provides smooth and powerful acceleration anddeceleration.
•Wide Lineup of Optional BoardsThe optional water supply, PG support, and serial communication boards can be used to upgradethe performance and functions of the SAMCO-i general purpose inverter.
0 800ms
■Speed step response
Motor primary current
Motor speed
Speed estimated value
Torque
■Load step response
0f=20→25Hz step
0
600
4000 (ms/div)
Motor speed command 125 (rpm/div)
Motor speed 125 (rpm/div)
Motor primary current 5 (A/div)
Sanken General Purpose Inverter
2
Sanken General Purpose Inverter
Model
Applicable motor capacity
Digital
Analog
Digital
Analog
Rated capacity
Rated current
Rated overload current capacity
Rated voltage/frequency
Power supply
Allowable fluctuation
Allowable momentary voltage drop
Control method
Modulation method
Setting frequency range
Frequency
setting resolution
Frequency accuracy
Voltage/frequency (V/f)
Torque boost
Acceleration/deceleration time
DC braking
Additional functions
Frequency
setting
Input signals
Output
signals
LED display
Protective functions
Ambient temperature
Ambient humidity
Operating environment
IHF-1.5K
1.5kW
2.8kVA
4.0A
IHF-2.2K
2.2kW
4.2kVA
6.0A
IHF-4.0K
4.0kW
6.2kVA
9.0A
IHF-5.5K
5.5kW
9.0kVA
13A
IHF-7.5K
7.5kW
12kVA
17A
IHF-11K
11kW
17kVA
25A
IHF-15K
15kW
22kVA
32A
Output
InputC
ontrol functionsO
perational functionsEnvironm
ental
conditions
Protective structure
Cooling method
Mass (Approx.)
Digital
Analog
Contact output
Open collector output
150% for 1 minute
3Φ 380V/50Hz, 400V/50Hz, 460V/60Hz
3Φ 380V to 460V
Voltage: -15%, +10% Frequency: ±5%
320V and above: Continuous operation (short-time rating) Below 320V: 15msec operation
Totally enclosed type (IP20)
Forced air cooling
V/f control or Sensorless Vector Control
Sinusoidal PWM
0.2Hz to 400Hz (starting frequency of 0.2Hz to 20Hz possible)
0.01Hz(0.05Hz to 120Hz)
0.1% (10-bit 0 to 10V, 4 to 20mA), 0.2% (9-bit 0 to 5V) at maximum output frequency
±0.01% of output frequency (at -10℃ to +50℃)
±0.2% of maximum output frequency (at 25 ± 10)
0 to 10%
Starting frequency (0.5Hz to 20Hz), braking time (0.1sec to 10 sec), braking force (1 to 10 steps)
Operation panel
0 to 5V, 0 to 10V, 4 to 20mA or variable resistor (5kΩ)
Alarm batch (1C contact 250VAC, 0.3A)
Operation, frequency coincidence, overload warning, undervoltage, frequency reach
Frequency, output current, synchronous rotation, line speed (free unit), alarms, charging indicator for capacitor
-10℃ to +50℃
Below 90% (no condensation allowed)
Indoors at an altitude below 1,000m (Do not expose to direct sunlight, or subject to corrosive or flammable gas, oil mist or dust.)
3kg 5kg 10kg
※1:Rated capacity: Capacity at an output voltage of 400V※2:Setting frequency range for Sensorless Vector Control: 1Hz to 120Hz※3:Maximum output frequency: Frequency at 5V, 10V, 20mA※4:Acceleration/deceleration time: Time from 0 to the reference acceleration/deceleration frequency.※5:V/f mode: From 0.1 seconds.
※1
※4
※3
※5
※2
Flying start, acceleration/deceleration stall prevention, momentary voltage drop compensation, multiple speed operation, frequency jump, restart after momentary power break, automatic alarm reset, energy-saving operation, pattern operation, PID control operation, torque limiter (only sensorless vector)
0 to 6,500 sec. (independent setting of acceleration/deceleration time possible) Linear or programmable S-curve can be selected.
Frequency command, forward command, reverse command, frequency setting selection, acceleration/deceleration time selection, free-run stop/alarm reset, emergency stop, multiple speed, jogging selection, step frequency selection, operation signal holding, torque limiter (only sensorlessvector)
Any base frequency setting between 30Hz and 400Hz can be set. (Constant torque and reduced torque pattern can be selected.)
Current limit, overcurrent shutdown, motor overload, external thermal protection, undervoltage, momentary power break, overvoltage, cooling fin overheat, output open-phase
※3
SAMCO-ihF (1.5kW~15kW)
S P E C I F I C A T I O N S
3
Standard Specifications
Model
Applicable motor capacity
Digital
Analog
Digital
Analog
Rated capacity
Rated current
Rated overload current capacity
Rated voltage/frequency
Power supply
Allowable fluctuation
Allowable momentary voltage drop
Control method
Modulation method
Setting frequency range
Frequency
setting resolution
Frequency accuracy
Voltage/frequency (V/f)
Torque boost
Acceleration/deceleration time
DC braking
Additional functions
Frequency
setting
Input signals
Output
signals
LED display
Protective functions
Ambient temperature
Ambient humidity
Operating environment
IHF-18.5K
18.5kW
27kVA
39A
IHF-22K
22kW
32kVA
46A
IHF-30K
30kW
43kVA
62A
IHF-37K
37kW
51kVA
74A
IHF-45K
45kW
62kVA
90A
IHF-55K
55kW
76kVA
110A
Output
InputC
ontrol functionsO
perational functionsEnvironm
ental
conditions
Protective structure
Cooling method
Mass (Approx.)
Digital
Analog
Contact output
Open collector output
150% for 1 minute
3Φ 380V/50Hz, 400V/50Hz, 460V/60Hz
3Φ 380V to 460V
Voltage: -15%, +10% Frequency: ±5%
320V and above: Continuous operation (short-time rating) Below 320V: 15msec operation
Totally enclosed type (IP20)
Forced air cooling
V/f control or Sensorless Vector Control
Sinusoidal PWM
0.2Hz to 400Hz (starting frequency of 0.2Hz to 20Hz possible)
0.01Hz(0.05Hz to 120Hz)
0.1% (10-bit 0 to 10V, 4 to 20mA), 0.2% (9-bit 0 to 5V) at maximum output frequency
±0.01% of output frequency (at -10℃ to +50℃)
±0.2% of maximum output frequency (at 25 ±10℃)
0 to 10%
Starting frequency (0.5Hz to 20Hz), braking time (0.1sec to 10 sec), braking force (1 to 10 steps)
Operation panel
0 to 5V, 0 to 10V, 4 to 20mA or variable resistor (5kΩ)
Alarm batch (1C contact 250VAC, 0.3A)
Operation, frequency coincidence, overload warning, undervoltage, frequency reach
Frequency, output current, synchronous rotation, line speed (free unit), alarms, charging indicator for capacitor
-10℃ to +50℃
Below 90% (no condensation allowed)
Indoors at an altitude below 1,000m (Do not expose to direct sunlight, or subject to corrosive or flammable gas, oil mist or dust.)
17kg 29kg 39kg
※1:Rated capacity: Capacity at an output voltage of 400V※2:Setting frequency range for Sensorless Vector Control: 1Hz to 120Hz※3:Maximum output frequency: Frequency at 5V, 10V, 20mA※4:Acceleration/deceleration time: Time from 0 to the reference acceleration/deceleration frequency.※5:V/f mode: From 0.1 seconds.
※1
※4
※3
※5
※2
Flying start, acceleration/deceleration stall prevention, momentary voltage drop compensation, multiple speed operation, frequency jump, restart after momentary power break, automatic alarm reset, energy-saving operation, pattern operation, PID control operation, torque limiter (only sensorless vector)
0 to 6,500 sec. (independent setting of acceleration/deceleration time possible) Linear or programmable S-curve can be selected.
Frequency command, forward command, reverse command, frequency setting selection, acceleration/deceleration time selection, free-run stop/alarm reset, emergency stop, multiple speed, jogging selection, step frequency selection, operation signal holding, torque limiter (only sensorless vector)
Any base frequency setting between 30Hz and 400Hz can be set. (Constant torque and reduced torque pattern can be selected.)
Current limit, overcurrent shutdown, motor overload, external thermal protection, undervoltage, momentary power break, overvoltage, cooling fin overheat, output open-phase
※3
SAMCO-ihF (18.5kW~55kW)
Sanken General Purpose Inverter
S P E C I F I C A T I O N S
4
Standard Specifications
Sanken General Purpose Inverter
Model
Applicable motor capacity
Digital
Analog
Digital
Analog
Rated capacity
Rated current
Rated overload current capacity
Rated voltage/frequency
Power supply
Allowable fluctuation
Allowable momentary voltage drop
Control method
Modulation method
Setting frequency range
Frequency
setting resolution
Frequency accuracy
Voltage/frequency (V/f)
Torque boost
Acceleration/deceleration time
DC braking
Additional functions
Frequency
setting
Input signals
Output
signals
�
LED display
Protective functions
Ambient temperature
Ambient humidity
Operating environment
IHF-75K
75kW
102kVA
147A
IHF-90K
90kW
120kVA
173A
IHF-110K
110kW
146kVA
211A
IHF-132K
132kW
175kVA
253A
IHF-160K
160kW
211kVA
304A
IHF-220K
220kW
295kVA
426A
IHF-250K
250kW
327VA
472A
Output
InputC
ontrol functionsO
perational functionsEnvironm
ental
conditions
Protective structure
Cooling method
Mass (Approx.)
Digital
Analog
Contact output
Open collector output
Analog output
150% for 1 minute
3Φ 380V/50Hz, 400V/50Hz, 460V/60Hz
3Φ 380V to 460V
Voltage: -15%, +10% Frequency: ±5%
320V and above: Continuous operation (short-time rating) Below 320V: 15msec operation
Totally enclosed type (IP20)
Forced air cooling
V/f control or Sensorless Vector Control
Sinusoidal PWM
0.05Hz to 400Hz (starting frequency of 0.05Hz to 20Hz possible)
0.01Hz(0.05Hz to 120Hz)
0.1% (10-bit 0 to 10V, 4 to 20mA), 0.2% (9-bit 0 to 5V) at maximum output frequency
±0.01% of output frequency (at -10℃ to +50℃)
±0.2% of maximum output frequency (at 25 ± 10℃)
0 to 10%
Starting frequency (0.5Hz to 20Hz), braking time (0.1sec to 10 sec), braking force (1 to 10 steps)
Operation panel
0 to 5V, 0 to 10V, 4 to 20mA or variable resistor (5kΩ)
Alarm batch (1C contact 250VAC, 0.3A)
Operation, frequency coincidence, overload warning, undervoltage, frequency reach
Select from setting frequency, output frequency, output current, DC current, heater temperature, load rate, analog input (VRF, IRF)
Frequency, output current, synchronous rotation, line speed (free unit), alarms, charging indicator for capacitor
-10℃ to +50℃
Below 90% (no condensation allowed)
Indoors at an altitude below 1,000m (Do not expose to direct sunlight, or subject to corrosive or flammable gas, oil mist or dust.)
70kg65kg 110kg 160kg 280kg155kg
※1:Rated capacity: Capacity at an output voltage of 400V※2:Setting frequency range for Sensorless Vector Control: 5Hz to 120Hz for rated frequency 1, 1Hz to 120Hz for rated frequency 2※3:Maximum output frequency: Frequency at 5V, 10V, 20mA※4:Acceleration/deceleration time: Time from 0 to the reference acceleration/deceleration frequency.※5:V/f mode: From 0.1 seconds.
※1
※4
※5
※5
※2
Flying start, acceleration/deceleration stall prevention, momentary voltage drop compensation, multiple speed operation, frequency jump, restart after momentary power break, automatic alarm reset, energy-saving operation, pattern operation, PID control operation, torque limiter (only sensorless vector)
0 to 6,500 sec. (independent setting of acceleration/deceleration time possible) Linear or programmable S-curve can be selected.
Frequency command, forward command, reverse command, frequency setting selection, acceleration/deceleration time selection, free-run stop/alarm reset, emergency stop, multiple speed, jogging selection, step frequency selection, operation signal holding, torque limiter (only sensorless vector)
Any base frequency setting between 30Hz and 400Hz can be set. (Constant torque and reduced torque pattern can be selected.)
Current limit, overcurrent shutdown, motor overload, external thermal protection, undervoltage, momentary power break, overvoltage, cooling fin overheat, output open-phase
※3
SAMCO-ihF (75kW~250kW)
S P E C I F I C A T I O N S
5
Standard Specifications
SAMCO-ipF (7.5kW~55kW)
Sanken General Purpose Inverter
Model
Applicable motor capacity
Digital
Analog
Digital
Analog
Rated capacity
Rated current
Rated overload current capacity
Rated voltage/frequency
Power supply
Allowable fluctuation
Allowable momentary voltage drop
Control method
Modulation method
Setting frequency range
Frequency
setting resolution
Frequency accuracy
Voltage/frequency (V/f)
Torque boost
Acceleration/deceleration time
DC braking
Additional functions
Frequency
setting
Input signals
Output
signals
LED display
Protective functions
Ambient temperature
Ambient humidity
Operating environment
IPF-7.5K
7.5kW
12kVA
17A
IPF-11K
11kW
17kVA
25A
IPF-15K
15kW
22kVA
32A
IPF-22K
22kW
32kVA
46A
IPF-18.5K
18.5kW
27kVA
39A
IPF-30K
30kW
43kVA
62A
IPF-37K
37kW
51kVA
74A
IPF-55K
55kW
76kVA
110A
IPF-45K
45kW
62kVA
90A
Output
InputC
ontrol functionsO
perational functionsEnvironm
ental
conditions
Protective structure
Cooling method
Mass (Approx.)
Digital
Analog
Contact output
Open collector output
120% for 1 minute
3Φ 380V/50Hz, 400V/50Hz, 460V/60Hz
3Φ 380V to 460V
Voltage: -15%, +10% Frequency: ±5%
320V and above: Continuous operation (short-time rating) Below 320V: 15msec operation
Totally enclosed type (IP20)
Forced air cooling
V/f control or Sensorless Vector Control
Sinusoidal PWM
0.2Hz to 400Hz (starting frequency of 0.2Hz to 20Hz possible)
0.01Hz(0.05Hz to 120Hz)
0.1% (10-bit 0 to 10V, 4 to 20mA), 0.2% (9-bit 0 to 5V) at maximum output frequency
±0.01% of output frequency (at -10℃ to +50℃)
±0.2% of maximum output frequency (at 25 ±10℃)
0 to 10%
Starting frequency (0.5Hz to 20Hz), braking time (0.1sec to 10 sec), braking force (1 to 10 steps)
Operation panel
0 to 5V, 0 to 10V, 4 to 20mA or variable resistor (5kΩ)
Alarm batch (1C contact 250VAC, 0.3A)
Operation, frequency coincidence, overload warning, undervoltage, frequency reach
Frequency, output current, synchronous rotation, line speed (free unit), alarms, charging indicator for capacitor
-10℃ to +50℃
Below 90% (no condensation allowed)
IIndoors at an altitude below 1,000m (Do not expose to direct sunlight, or subject to corrosive or flammable gas, oil mist or dust.)
6kg 10kg 17kg 27kg 39kg
※1:Rated capacity: Capacity at an output voltage of 400V※2:Setting frequency range for Sensorless Vector Control: 1Hz to 120Hz※3:Maximum output frequency: Frequency at 5V, 10V, 20mA※4:Acceleration/deceleration time: Time from 0 to the reference acceleration/deceleration frequency.※5:V/f mode: From 0.1 seconds.
※1
※4
※3
※5
※2
Flying start, acceleration/deceleration stall prevention, momentary voltage drop compensation, multiple speed operation, frequency jump, restart after momentary power break, automatic alarm reset, energy-saving operation, pattern operation, PID control operation, torque limiter (only sensorless vector)
0 to 6,500 sec. (independent setting of acceleration/deceleration time possible) Linear or programmable S-curve can be selected.
Frequency command, forward command, reverse command, frequency setting selection, acceleration/deceleration time selection, free-run stop/alarm reset, emergency stop, multiple speed, jogging selection, step frequency selection, operation signal holding, torque limiter (only sensorless vector)
Any base frequency setting between 30Hz and 400Hz can be set. (Constant torque and reduced torque pattern can be selected.)
Current limit, overcurrent shutdown, motor overload, external thermal protection, undervoltage, momentary power break, overvoltage, cooling fin overheat, output open-phase
※3
S P E C I F I C A T I O N S
6
Standard Specifications
Sanken General Purpose Inverter
Model
Applicable motor capacity
Digital
Analog
Digital
Analog
Rated capacity
Rated current
Rated overload current capacity
Rated voltage/frequency
Power supply
Allowable fluctuation
Allowable momentary voltage drop
Control method
Modulation method
Setting frequency range
Frequency
setting resolution
Frequency accuracy
Voltage/frequency (V/f)
Torque boost
Acceleration/deceleration time
DC braking
Additional functions
Frequency
setting
Input signals
Output
signals
�
LED display
Protective functions
Ambient temperature
Ambient humidity
Operating environment
IPF-75K
75kW
102kVA
147A
IPF-90K
90kW
120kVA
173A
IPF-110K
110kW
146kVA
211A
IPF-132K
132kW
175kVA
253A
IPF-160K
160kW
211kVA
304A
IPF-280K
280kW
374kVA
540A
IPF-220K
220kW
295kVA
426A
IPF-315K
315kW
409VA
590A
Output
InputC
ontrol functionsO
perational functionsEnvironm
ental
conditions
Protective structure
Cooling method
Mass (Approx.)
Digital
Analog
Contact output
Open collector output
Analog output
150% for 1 minute
3Φ 380V/50Hz, 400V/50Hz, 460V/60Hz
3Φ 380V to 460V
Voltage: -15%, +10% Frequency: ±5%
320V and above: Continuous operation (short-time rating) Below 320V: 15msec operation
Totally enclosed type (IP20)
Forced air cooling
V/f control or Sensorless Vector Control
Sinusoidal PWM
0.05Hz to 400Hz (starting frequency of 0.05Hz to 20Hz possible)
0.01Hz(0.05Hz to 120Hz)
0.1% (10-bit 0 to 10V, 4 to 20mA), 0.2% (9-bit 0 to 5V) at maximum output frequency
±0.01% of output frequency (at -10℃ to +50℃)
±0.2% of maximum output frequency (at 25 ± 10℃)
0 to 10%
Starting frequency (0.5Hz to 20Hz), braking time (0.1sec to 10 sec), braking force (1 to 10 steps)
Operation panel
0 to 5V, 0 to 10V, 4 to 20mA or variable resistor (5kΩ)
Alarm batch (1C contact 250VAC, 0.3A)
Operation, frequency coincidence, overload warning, undervoltage, frequency reach
Select from setting frequency, output frequency, output current, DC current, heater temperature, load rate, analog input (VRF, IRF)
Frequency, output current, synchronous rotation, line speed (free unit), alarms, charging indicator for capacitor
-10℃ to +50℃�
Below 90% (no condensation allowed)
IIndoors at an altitude below 1,000m (Do not expose to direct sunlight, or subject to corrosive or flammable gas, oil mist or dust.)
70kg65kg 110kg 110kg 1154kg 280kg 280kg160kg
※1:Rated capacity: Capacity at an output voltage of 400V※2:Setting frequency range for Sensorless Vector Control: 5Hz to 120Hz for rated frequency 1, 1Hz to 120Hz for rated frequency 2※3:Maximum output frequency: Frequency at 5V, 10V, 20mA※4:Acceleration/deceleration time: Time from 0 to the reference acceleration/deceleration frequency.※5:V/f mode: From 0.1 seconds.
※1
※4
※5
※5
※2
Flying start, acceleration/deceleration stall prevention, momentary voltage drop compensation, multiple speed operation, frequency jump, restart after momentary power break, automatic alarm reset, energy-saving operation, pattern operation, PID control operation, torque limiter (only sensorless vector)
0 to 6,500 sec. (independent setting of acceleration/deceleration time possible) Linear or programmable S-curve can be selected.
Frequency command, forward command, reverse command, frequency setting selection, acceleration/deceleration time selection, free-run stop/alarm reset, emergency stop, multiple speed, jogging selection, step frequency selection, operation signal holding, torque limiter (only sensorless vector)
Any base frequency setting between 30Hz and 400Hz can be set. (Constant torque and reduced torque pattern can be selected.)
Current limit, overcurrent shutdown, motor overload, external thermal protection, undervoltage, momentary power break, overvoltage, cooling fin overheat, output open-phase
※3
SAMCO-ipF (75kW~315kW)
S P E C I F I C A T I O N S
7
Standard Specifications
Sanken General Purpose Inverter
SAMCO-ihF (1.5kW~15kW)-ipF (7.5kW~18.5kW)
D
B A
C
4-φF
警告�■��■�
xxxxxxxxxxxxxxx�xxxx�xxxxxxxxxxxxxxx�xxxxxxxxxxxxxxx�xxxxxxxx
COIUTUON■��■�
xxxxxxxxxxxxxxx�xxxx�xxxxxxxxxxxxxxx�xxxxxxxxxxxxxxx�xxxxxxxx
FWD REV STOP
DISP�CLEAR
ENTER
PROG
REDY r/min A Hz
E
INVERTER
OUTPUT�
MONITOR�
LOT NO. Mas.
SAMCO-GG-Co. LTD
TYPE
50Hz/60Hz�
o o A�
o o o KW
•Front view •Side view
ModelA B C D E F
ihF Series ipF Series
IHF-1.5K
IHF-2.2K
IHF-4.0K
IHF-5.5K
IHF-7.5K
IHF-11K
IHF-15K
IPF-7.5K
IPF-11K
IPF-15K
IPF-18.5K
250
300
360
238
280
340
140
200
240
128
180
220
155
190
200
5
7
7
(Unit: mm)
S I Z E
8
External Dimensions
Sanken General Purpose Inverter
SAMCO-ihF (18.5kW~55kW)-ipF (22kW~55kW)
D
B A
C
G
2-φF
FWD REV STOP
DISP�CLEAR
ENTER
PROG
REDY r/min A Hz
警告�■��■�
xxxxxxxxxxxxxxx�xxxx�xxxxxxxxxxxxxxx�xxxxxxxxxxxxxxx�xxxxxxxx
COIUTUON■��■�
xxxxxxxxxxxxxxx�xxxx�xxxxxxxxxxxxxxx�xxxxxxxxxxxxxxx�xxxxxxxx
INVERTER
SOUCE JPN 586V-598V
OUTPUT�MONITOR�LOT NO. Mas.SAMCO-GG-Co. LTD
TYPE
50Hz/60Hz�o o A�
o o o KW
E
•Front view •Side view
ModelA B C D E F G
ihF Series ipF Series
IHF-18.5K
IHF-22K
IHF-30K
IHF-37K
IHF-45K
IHF-55K
IPF-37K
IPF-45K
IPF-22K
IPF-30K
IPF-55K
380
440
580
355
410
550
270
360
360
240
325
325
220
260
270
7
7
9
7
7
9
(Unit: mm)
S I Z E
9
External Dimensions
Sanken General Purpose Inverter
SAMCO-ihF (75kW~250kW)-ipF (75kW~315kW)
D
HB A
C
G
2-φF
FWD REV STOP
DISP�CLEAR
ENTER
PROG
REDY r/min A Hz
INVERTER
SOUCE JPN 586V-598V
OUTPUT�MONITOR�LOT NO. Mas.SAMCO-GG-Co. LTD
TYPE
50Hz/60Hz�o o A�
o o o KW
�E
2-φ20�(wall-mounting hole)�
•Front view •Side view
ModelA B C D E F G H
ihF Series ipF Series
IHF-110K
IHF-132K
IHF-160K
IHF-250K
IPF-75K
IPF-132K
IPF-160K
IHF-90K IPF-110K
IHF-75K IPF-90K
IPF-220K
IPF-315K
690
690
850
990
1150
655
655
810
950
1100
385
460
530
700
800
300
375
400
600
600
295
295
370
380
465
12
12
12
15
18
12
12
12
15
18
15
15
15
17.5
25
(Unit: mm)
S I Z E
10
External Dimensions
・New publication,effective feb.1999
・Specifications are subject to change without notice.
・For typographical reasons,the color tones of the products featured in this brochure may vary from those of the actual products.
SANKEN ELECTRIC CO., LTD.1-11-1 NISHI-IKEBUKURO, TOSHIMA-KU, TOKYO, JAPANTEL: 03-3986-8061 FAX: 03-3986-6240
SANKEN POWER SYSTEMS (UK) LTD.ABERCYON, MOUNTAIN ASH, MID GLAM., CF45 4XA,SOUTH WALES U.K.TEL: 01443-742333 FAX: 01443-742100
KOREA SANKEN CO.,LTD.BG-1 FREE ZONE EXPORT MASAN 974-17 YANG DUK-DONG,HEOIWON-GU,MASAN KOREATEL:0551-92-5961~6 FAX:0551-96-8938,92-5960
SANKEN L.D.CO.LIMITEDRM.703-704 CONCORDIA PLAZA,1 SCIENCE MUSEUM RD.,T.S.T.EAST,KLN.H.K.TEL:2721-3611,3211-6003 TELEX:48606 LDETC HXFAX:2721-6405 CABLE:1029
SeriesCapacity (kW) SAMCO-ihF
0.4
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
220
250
280
315
SAMCO-ipF SAMCO-QS SAMCO-QT SAMCO-iT SAMCO-iF(CE mark)
●:Available now、○Available soon
L I N E - U PSAMCO Series Lineup
Safety PrecautionsBe sure to adhere to the following precautions when using your SAMCO-ihF,ipF Series product.
Be sure to carefully read "Instruction Manual"which is attached with product,before using the unit,then use it correctly.And also,be sure to clearly
follow the operating conditions and environmental conditions listed in this catalog.
The SAMCO-ihF,ipF units are designed for variable speed control of a general,industrial purpose 3-phase AC induction motor.
Note:Contact a customer service representative if any load other than a 3-phase AC induction motor is used.
The SAMCO-ihF,ipF untis shall not be used for the following systems where damage or malfunction could result in injury or loss of life.
a.Passenger transit systems b.Medical facilities c.Nuclear/Electric power control systems d.Aviation/Aerospace systems
e.Traffic/Transportation systems f.Safety systems g.Special purpose systems
Note:Contact a customer service representative before using the unit with these systems.
The SAMCO-ihF,ipF products require certain electrical wiring and should be installed by a qualified electrical technician.
K1-V07EA1-9902005ND