4. cathodic protectionlyonsengineers.com/vol_ii of ii_tech laying-part-2.pdf(qjlqhhulqj 6wdqgdug...
TRANSCRIPT
4. CATHODIC PROTECTION
Remarks
M C TPIA
Approved Drawing & Data Sheet Inspection Report P W W
Approved Drawing & Data Sheet Inspection Report P W W
Approved Drawing Inspection Report P W W
fitness test, terminal to body resistance.
Randamly Approved Drawing & Data Sheet Inspection Report P W W
Approved Drawing Inspection Report P W W
Approved Drawing & Data Sheet Inspection Report P W W
Approved Drawing & Data Sheet IP 55 Test Certificate S R R
Approved Drawing & Data SheetIRN H P R
OWNER
PROJECT
QUALITY ASSURANCE PLAN FOR TEST STATIONS
PROJECT NO
TPIA
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.
DATE:-
CONTRACTOR
CP CONTRACTOR
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001
QAP NO 01 REV. 0
REFERENCE DESIGN DOCUMENT
REFERENCE DATA SHEET
REFERENCE DRAWING
VENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Visual Inspection: 100%
Dimensional Check: 25%
Manufacturer Test Certificate (IP 55)
Document / Marking
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency H-Hold
Thickness Check :25%
Terminals to TS Body
RemarksM C TPIA
Approved Drawing & Data Sheet Inspection Report P W/R W/R
Approved Drawing & Data Sheet Test Report P R W
PROJECT
QUALITY ASSURANCE PLAN FOR SECRIFICIAL ZINC ANODE
OWNER
QAP NO
DATE:-
02 REV. 0
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
PROJECT NOTPIA
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Destructive Testing
a. Surface 100 %, Length ± 2.5 %, Width/ Thickness ± 5%b. Visual : Longitudinal cracks of more than 40 mm long and 3 mm deep not acceptable
c. Weight tolerance: + %5 (Total weight of all anodes shall not have negative tolerance)Radiographic Test
Approved Drawing & Data Sheet Test Report P W/R
Inspection
Approved Drawing & Data Sheet Inspection Report
W/R
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
One anode per heat shall be subjected to radiography to evaluate cracks, voids, slack inclusion etc.
W/R
One anode per heat shall be subjected to destructive testing for slag inclusions, bond between anode and
insert.
W/RP
RemarksM C TPIA
PROJECT
QUALITY ASSURANCE PLAN FOR SECRIFICIAL ZINC ANODE
OWNER
QAP NO
DATE:-
02 REV. 0
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
PROJECT NOTPIA
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Approved Drawing & Data Sheet Test Report P R R
Approved Drawing & Data Sheet Test Report P R R
Mass per liner meter ALL Approved Drawing & Data Sheet Test Report P R W
Anode to core resistance Randamly Approved Drawing & Data Sheet Test Report P R W
Approved Drawing & Data Sheet Test ReportSubmission
R W
Approved Drawing & Data Sheet IRN H P R
be subjected to destructive testing for slag inclusions, bond between anode and insert.
Document / Marking
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency
R Wa.)Open circuit potential shall lie within (+) 10 mV and (-) 50 mV of the guaranteed value.b.)Consumption rate by weight loss method (consumption rate shall not be more than the specified value).
All the above Manufacturer Test Reports
ChemicaL Analysis; One anode sample per heat by Spectrography Sample in the beginning for first heat, end of second heat, at the beginning of third heat and so on.
Electrochemical Test
Approved Drawing & Data Sheet Test Report R
RemarksM C TPIA
Approved Drawing & Data Sheet Inspection Report P W R
CONTRACTORCP CONTRACTOR
DATE:-
03 REV. 0
REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORD
PROJECTOWNERPROJECT NOTPIACONSULTANT Lyons Engineering Engineering Pvt. Ltd.
QAP NOREFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001
INSPECTION BY
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)Inspection
Approved Drawing & Data Sheet Inspection Report P W/R
a. Surface 100 %, Length ± 2.5 %, Width/ Thickness ± 5%b. Visual : Longitudinal cracks of more than 40 mm long and 3 mm deep not acceptablec. Weight tolerance: + %5 (Total weight of all anodes shall not have negative tolerance)
W
One anode per heat shall be subjected to radiography to evaluate cracks, voids, slack inclusion etc.
Destructive Testing
Approved Drawing & Data Sheet Test Report P R R
Radiographic Test
Approved Drawing & Data Sheet Test Report P W
One anode per heat shall be subjected to destructive testing for slag inclusions, bond between anode and insert.
QUALITY ASSURANCE PLAN FOR SACRIFICIAL MAGNESIUM ANODE
W
RemarksM C TPIA
CONTRACTORCP CONTRACTOR
DATE:-
03 REV. 0
REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORD
PROJECTOWNERPROJECT NOTPIACONSULTANT Lyons Engineering Engineering Pvt. Ltd.
QAP NOREFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001
INSPECTION BY
QUALITY ASSURANCE PLAN FOR SACRIFICIAL MAGNESIUM ANODE
Approved Drawing & Data Sheet Test Report P R R
Mass per liner meter ALL Approved Drawing & Data Sheet Test Report P R W
Anode to core resistance Randamly Approved Drawing & Data Sheet Test Report P R W
Approved Drawing & Data Sheet Test Report Submission
R R
Approved Drawing & Data Sheet IRNH P RDocument / Marking
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency
R R
One anode per heat shall be tested fora.)Open circuit potential shall lie within (+) 10 mV and (-) 50 mV of the
b.)Consumption rate by weight loss method (consumption rate shall not be more than the specified value).
R
ChemicaL Analysis; One anode sample per heat by Spectrography Sample in the beginning for first heat, end of second heat, at the beginning of third heat and so on.
Electrochemical Test
Approved Drawing & Data Sheet
Test Report
All the above Manufacturer Test Reports
RemarksM C TPIA
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
ALL Approved Data Sheet Inspection Report P W W
Diamentional Check ALL Approved Drawing & Data Sheet Inspection Report P W W
Electrical Test , coating consumtion rate ALL Approved Drawing & Data Sheet Inspection Report P W W
Leak proof test (Helium Test), cable length, coating resistivity & Coating thickness
Randamly Approved Drawing & Data Sheet Inspection Report P W W
Inspection as per below attached vendor’s ITP
ALL Vendor’s ITP is attached below Inspection Report P R R
Document / Marking ALL Approved Drawing & Data Sheet IRN H P R
PROJECT NOTPIA
DATE:-
PROJECT
QUALITY ASSURANCE PLAN FOR MMO ANODE
OWNER
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENT
QAP NO 04 REV. 0
REFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency H-Hold
RemarksM C TPIA
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Approved Data Sheet & Design Specification
Inspection Report Inspection Report P W/R W/R
Manufacturer Test Report
Approved Data Sheet & Design Specification
Test Certificate Test Certificate P R R
Inspection Release Note IRN H P R
OWNER
PROJECT
QUALITY ASSURANCE PLAN FOR POLARISATION CELL
PROJECT NO
TPIA
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.
DATE:-
CONTRACTOR
CP CONTRACTOR
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001
QAP NO 05 REV. 0
REFERENCE DESIGN DOCUMENT
REFERENCE DATA SHEET
REFERENCE DRAWING
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency H-Hold
VENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENT FORMAT OF RECORDINSPECTION BY
RemarksM C TPIA
Approved Data Sheet & Drawing Inspection ReportP W / R W/R
Approved Data Sheet & Drawing/ Technical specification P W / R W/R
Approved Data Sheet & Drawing Test Certificate Submission
R R
IRNH P R
PROJECT NO
TPIA
DATE:-
PROJECT
QUALITY ASSURANCE PLAN FOR PERMANENT REFERENCE CELL (Ag/Agcl)
OWNER
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.
CONTRACTOR
CP CONTRACTOR
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001
REFERENCE DESIGN DOCUMENT
QAP NO 06 REV. 0
REFERENCE DATA SHEET
REFERENCE DRAWING
VENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Manufacturer Certificates
Inspection Release Note
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency H-Hold
Visual Inspection 100%
RemarksM C TPIA
Approved Data Sheet & Drawing Inspection Report P W / R W/R
Approved Data Sheet & Drawing Test CertificateSubmission
R R
IRN H H P
PROJECT
QUALITY ASSURANCE PLAN FOR PERMANENT REFERENCE CELL (Cu/CuSo4)
OWNER
QAP NO
DATE:-
07 REV. 0
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
PROJECT NOTPIA
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Manufacturer Certificates
Inspection Release Notee
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency
REMARKS
M TPIA CLIENT1 BOUGHT OUT ITEMS
1. Physical Check Measuring Tape 100%Approved Drawing
Manufacturer specification
Incoming Test Certificate
Incoming Test Certificate
P R R
2 Physical damge if any. Physical Test 1 in Lot P3 Verification with Manufacturer specification.
Verification of Test Certificate
Approved Drawing P R R
1.2Receving Inspection of Meters,PCB'S,Semiconductor & Electrical Iterms
1. Dimensions, SizeFunctional test 2.Mechnical/Ele ctrical Measurement
sampling 10%Approved Drawing
Manufacturer specification
Test Report
1.Manufacturer Test Report
2.IncomingTest Report
P R R
2. Electrical Parameters 1 in Lot P W W
1.3Sub assembly- Transformer,Choke,
1. Insulation Test 2. No Load Test
100% Approved drawing Test Certificate Test Certificate P R R
1.4Sub assembly- Timer-Inspection & Test
1. Visual inspection 2. Functional Test 3. Internal settings
Functional test 2.Mechnical/Ele ctrical
100% Approved drawing Test Certificate Test Certificate P R R
1.5 Assembly Process1. Electrical wiring and tighteness of all connections 2. Labeling and Marking
Measurement Visual 100% Approved drawing Test Report Test Report P R R
1.6 Auxilary device check Verification as per BOM Visual 100% Approved Drawing Test Report Test Report P R R
1.7 Insulation Test
Insulation and High Voltage Test between primary to Earth,Secondary to Earth and/or Primary to secondary
Electrical Measurement
100% Approved Drawing Test Report Test Report P R R
1.8Sub/assembly-control card Inspection & Test
1. Visual inspection 2. Functional Test
Functional Test 100% Approved Drawing Test Report Test Report P R R
1.9 Heat Run Test
Heat run at at rated Load for at least 12/16 Hrs with Temperature measurement on all power devices and Magnetics at the end of test
Electrical Test & Inspection
100%
1.Approved Drawing 2.Approved Specification
Test Report Test Report P R R
Lyons Engineering Engineering Pvt. Ltd.0
PROJECTCLIENT REV. NO.-
QAP FOR TRANSFORMER UNIT
PMC
QAP NO.
MANUFACTURERP.O NO.
CONTRACTOR
P.O DATE
REF. DOC.08
RATING AND QUANTITYDATE:-
AgencyItem/ Component Characterstics Type of Check
Reference Document
Acceptance Norms
Format of RecordExtent of WorkSr.No.
Receving Inspection for Fabricated
1
REMARKS
M TPIA CLIENT
Lyons Engineering Engineering Pvt. Ltd.0
PROJECTCLIENT REV. NO.-
QAP FOR TRANSFORMER UNIT
PMC
QAP NO.
MANUFACTURERP.O NO.
CONTRACTOR
P.O DATE
REF. DOC.08
RATING AND QUANTITYDATE:-
AgencyItem/ Component Characterstics Type of Check
Reference Document
Acceptance Norms
Format of RecordExtent of WorkSr.No.
6. Continuity (ON-OFF) Electrical 100% P R R
2 Functional Test of Unit
1. Visual Inspection 2. Insulation Test 3. Operation in Manual Mode 4. Operation in AVCC & Voltage/current. 5. Regulation 6. Operation in Auto and PSP regulation 7. Ripple content in DC Output 8. Indication and alarm 9. Remote signal and Potenrtial free contacts Conveter and Timer(if any)10.HV 11. Annuciation
Inspection 100%
1.Approved Drawing. 2. Approved Specification.
Test Report Test Report P W W
2.1 Heat Run Test
10.Efficiency/power factor Heat run at at rated Load for at least 8 Hrs with Temperature measurement on all power devices and Magnetics at the end of test
Electrical Test & Inspection
40%
1.Approved Drawing 2.Approved Specification
Test Report Test Report P W/R W/R
5 Inspection Release NoteTechnical
SpecificationTechnical
SpecificationH P R
10.1WarrantyCertificate P R R
10.2 Operation ManualP R R
LEGEND: P-PERFORM, W-WITNESSE, S-SUBMITTED, R-REVIEW OF RECORDS, H-HOLD, M-MANIFACTURER, C-CONTRACTOR, TPIA-THIRD PARTY INSPECTION AGENCY
FINAL TEST
6Documents to be Sumitted at time of Dispatch and Packing
RemarksM C TPIA
Approved Data Sheet & Drawing Inspection Report P W / R W/R
Approved Data Sheet & Drawing Test Certificate P R R
IRN H P R
PROJECT NOTPIA
DATE:-
PROJECT
QUALITY ASSURANCE PLAN FOR PLAN SURGE DIVERTER
OWNER
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENT
QAP NO 09 REV. 0
REFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Manufacturer TEST Report
Inspection Release Note
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency
RemarksM C TPIA
Approved Data Sheet & Drawing Inspection Report P W / R W/R
Approved Data Sheet & Drawing Test CertificateSubmission
R R
IRN H H P
PROJECT
QUALITY ASSURANCE PLAN FOR ER PROBE & ER PROBE READER
OWNER
QAP NO
DATE:-
10 REV. 0
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
PROJECT NOTPIA
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
Inspection Release Note
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Manufacturer Certificates
RemarksM C TPIA
Approved Drawing & Data Sheet Inspection Report P W w
Visual Inspection ALL Approved Drawing & Data Sheet Inspection Report P W W
Dimensional Check, Physical verification, locking , painting
ALL Approved Drawing & Data Sheet Inspection Report P W W
Fitness Test Randamly Approved Drawing & Data Sheet Inspection Report P W WThickness check, Terminal to body check
ALL Approved Drawing & Data Sheet Inspection Report P W W
Manufacturer Test Certificate (IP 55) ALL Approved Drawing & Data SheetTest Report Submi
ssionR R
Approved Drawing & Data SheetIRN
H H P
PROJECT
QUALITY ASSURANCE PLAN FOR CATHODE JUNCTION BOX
OWNER
QAP NO
DATE:-
11 REV. 0
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
PROJECT NOTPIA
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Document/Marking
RemarksM C TPIA
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
ALL Approved Drawing & Data Sheet Inspection Report P W W
Visual Inspection ALL Approved Drawing & Data Sheet Inspection Report P W WDimensional Check, Physical verification, locking , painting
ALL Approved Drawing & Data Sheet Inspection Report P W W
Fitness Test Randamly Approved Drawing & Data Sheet Inspection Report P W WThickness check, Terminal to body check
ALL Approved Drawing & Data Sheet Inspection Report P W W
Manufacturer Test Certificate (IP 55) ALL Approved Drawing & Data Sheet Test Certificate P R RApproved Drawing & Data Sheet IRN H P R
PROJECT
QUALITY ASSURANCE PLAN FOR ANODE JUNCTION BOX
OWNER
QAP NO
DATE:-
12 REV. 0
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
PROJECT NOTPIA
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEET
Document / MarkingLEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency
REFERENCE DRAWINGVENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
RemarksM C TPIA
Approved Data Sheet & Drawing Inspection ReportP W / R W/R
Approved Data Sheet & Drawing Test Certificate Submission
R R
DATE:-
QUALITY ASSURANCE PLAN FOR PIPE CONNECTION
PROJECTOWNERPROJECT NOTPIACONSULTANT Lyons Engineering Engineering Pvt. Ltd.CONTRACTORCP CONTRACTOR
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001QAP NO 13 REV. 0
REFERENCE DESIGN DOCUMENTREFERENCE DATA SHEETREFERENCE DRAWINGVENDOR
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency H-Hold
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Compliance with approved Drawing & Data sheet (Manufacturer, type &Model)
Manufacturer Certificates
RemarksM C TPIA
Approved Data Sheet Inspection Report P W W
Approved Data Sheet Inspection Report P W W
Approved Data Sheet
Approved Data Sheet
Technical specification Test Report P W W
As per ref. Standard Test Report P W W
Approved Data Sheet Test Report P W P
Approved Data Sheet IRN H P R
OWNER
PROJECT
QUALITY ASSURANCE PLAN FOR CP CABLE
PROJECT NO
TPIA
CONSULTANT Lyons Engineering Engineering Pvt. Ltd.
DATE:-
CONTRACTOR
CP CONTRACTOR
REFERENCE SPECIFICATION ENG-STD-CP-DOC-TS-001
QAP NO 14 REV. 0
REFERENCE DESIGN DOCUMENT
REFERENCE DATA SHEET
REFERENCE DRAWING
VENDOR
DESCRIPTION / TYPE OF INSPECTION REFERENCE DOCUMENTFORMAT OF
RECORDINSPECTION BY
Compliance with approved Data sheet (Manufacturer, type )Visual Inspection: 100%
Voltage Test, Conductor Cross Section, Insulation Test -100% Inspection Report W WContinuity Check- Randamly
Manufacturer Test Reports
Document / Marking
LEGEND: P-PERFORM, W-WITNESS ALL, S-SUBMITTED BY, R-REVIEWED BY, H-HOLD M-Manufacturer C-Contractor TPIA-Third Party Inspection Agency H-Hold
P
Voltage Grade - Randamly
Type Test -100%
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
Civil/Structure Design Basis
QUANTITY
ANNEXURE-IV
INDICATIVE LIST OF STATUTORY ACTS & RULES
CONSTRUCTION HAZARDS, THEIR EFFECTS & PREVENTIVE MEASURES
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
ACTIVITY TYPE OF HAZARD
WITH SEAL
WITH SEAL
ITEM THIS MONTH CUMULTIVE
WITH SEAL
GRANT OF PERMIT AND EXTENSIONS