Page 1: 3M SelectiCure® H19 Cascade FilterThe 3WIT" SelectiCure ®H19 Cascade Filter is specifically designed for LDL apheresis SelectiCure® Surface area, m2 H19 1.9 Membrane Internal diameter,

3M" SelectiCure® H19Cascade Filter

Page 2: 3M SelectiCure® H19 Cascade FilterThe 3WIT" SelectiCure ®H19 Cascade Filter is specifically designed for LDL apheresis SelectiCure® Surface area, m2 H19 1.9 Membrane Internal diameter,

3M" SelectiCure® H19 Cascade FilterTherapeutic apheresis includes different types of extracorporeal removal of harmfulsubstances or therapeutically effective components from blood or blood plasma.Today, new treatment methods based on blood filtration enable new therapies fora broad spectrum of patients and indications.

One example is LDL apheresis, which eliminates the cholesterol-containing particlelow-density lipoprotein (LDL) from the bloodstream in patients with familialhypercholesterolemia. LDL-cholesterol, the so-called "bad cholesterol", plays a rolein the development of arteriosclerosis and increases the risk of coronary diseases,heart attack, and even death. When traditional lipid-lowering treatments may nothelp to lower the elevated LDL-cholesterol to the targeted level, LDL apheresisbecomes a feasible and effective option.

Scanning electron microscope (SEM)view on the membrane in 3M SelectiCureH19 Filter

SEM close up of the 3M SelectiCureH19 membrane

3M SelectiCure H19 membrane with P.E.T.°

spacer yarn

CI)

Patient

Pump

Pump

Waste

RinsingFluid

Page 3: 3M SelectiCure® H19 Cascade FilterThe 3WIT" SelectiCure ®H19 Cascade Filter is specifically designed for LDL apheresis SelectiCure® Surface area, m2 H19 1.9 Membrane Internal diameter,

The 3WIT" SelectiCure ®H19 Cascade Filter is specificallydesigned for LDL apheresis

SelectiCure®

Surface area, m2

H19

1.9

Membrane Internal diameter, pm 200

Wall thickness, pm 40

Membranematerial

PES

Fillingvolume

Blood side, ml 111

Plasma side, ml 250

Sterilization Gamma

Housing Polycarbonete or Copolyester

ConnectorsBlood connectors ISO 8637 (Twist-Lock)

Filtrate connectors ISO 8637 (Hansen)

Shelf life 5 years

3MT" SelectiCure ®H19 Cascade Filter

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

oAlbumin lgG HDL LDL

The in vitro performance of 3M" SelectiCure® H19 Cascade Filter measured with human plasma.

3M'mSelectiCure ®H19 Cascade Filter

• Selective depletion of plasma components• No requirement for substitution fluid• Dry filter• Low weight• Easy to prime and handle• ETO free

Page 4: 3M SelectiCure® H19 Cascade FilterThe 3WIT" SelectiCure ®H19 Cascade Filter is specifically designed for LDL apheresis SelectiCure® Surface area, m2 H19 1.9 Membrane Internal diameter,

■iire t A iv

.; /ter4<i ) 4 /1)

41V M? f A53s,

3A '6 vol

v•1

• OA11MO S))

4t ,

‘)

I , 0 you want to know more? www.3m.com/membrana

Product Use: Many factors beyond 3M's control and uniquely within user's knowledge and control can affect the use and performance of a 3M productin a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluatingthe 3M product and determining whether it is fit for a particular purpose and suitable for user's method of application.

Warranty, Limited Remedy, and Disclaimer: Unless an additional warranty is specifically stated on the applicable 3M product packaging or productliterature, 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the product. 3M MAKES NO OTHERWARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OFDEALING, CUSTOM OR USAGE OF TRADE. If the 3M product does not conform to this warranty, then the sole and exclusive remedy is, at 3M's option,replacement of the 3M product or refund of the purchase price.

Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct,indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability.

3M and SelectiCure are trademarks of 3M Company© 2016, 3M Company. All rights reserved.

CE0197

mil3M Deutschland GmbHMembranes Business UnitCarl-Schurz-Str. 141453 NeussGermany

www.3m.com/membrana

•I n e l s e G m b H

MEDIZINTECHNIKIm Gewerbepark 6 • 58579 Schalksmühle

Telefon 0 23 55 / 90 95 50 • Fax 0 23 55 / 90 95 [email protected] • www.meise.corn

laae

p A

lintm

t 90

16 R

FV

09.

RA

C S

Ple

ctiC

ure.

H19

CE

0197