Page 1: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAME® Self-Priming Process Pump with i-ALERT® Patented Intelligent Monitoring

Page 2: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

Self-Priming Process Pumps Designed for Total Range of Industry Services.

• Capacities to 284 m3/h (1250 GPM) • Heads to 131 m (430 feet) • Temperatures to 260° C (500° F) • Pressures to 1999 kPa (290 PSIG) • Effective static lift to 6 m (20 feet) Performance Features for Self-Priming Services

Extended Pump Life • One-piece casing with integral priming and air separation (no external priming chamber or air separator required). • No suction check valve required. • Rapid priming time. • Positive retention of pumpage under siphon conditions. • Self-purge of vapors. • i-FRAME Power Ends

Ease of Maintenance • Back pull-out design (one craft maintenance) • Parts interchangeable with Goulds 3196 • External impeller adjustment • Easy retrofit

Safety • ANSI B15.1 coupling guard • Ductile iron frame adapter • Fully serrated flanges

Services

• Industrial sump • Chemical transfer • Coal pile drainage • Filter systems • Aircraft fueling • Mine dewatering • Bilge water removal • Tank car unloading • Petroleum transfer • Column bottoms and reflux

2 3796 i-FRAME™

3796 i-FRAME

3796 i-FRAME (1x1½-6, 1½x1½-8)

3796 i-FRAME (2x2-10, 3x3-10, 4x4-10, 3x3-13, 4x4-13, 6x6-13)

Goulds 3796 i-FRAME process pump line is specifically designed to provide superior performance for self-priming services of the Chemical Process Industries.

Page 3: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAME™ 3

3796 i-FRAMEReliable Self-Priming Operation Before any centrifugal pump will perform, it must first be primed; that is, air or gases expelled from the suction and impeller eye area, and replaced with liquid. This is no problem when the pump is submerged (submersible or vertical sump pumps) or when liquid supply is above the pump. However, when suction pressure is negative, air must be evacuated to accomplish pump priming.

The 3796 i-FRAME is designed to ensure that a sufficient quantity of liquid to reprime is always retained in the priming chamber—a compact, integral and completely functional self-priming pump. The one-piece casing is designed with integral priming and air separation chambers. Priming is accomplished within the casing, eliminating the need for auxiliary priming systems.

Priming and Air Separation Accomplished Within Casing Dual volute design primes suction with only an initial charge of liquid in the casing. During the priming cycle, the lower volute functions as an intake while the upper volute discharges liquid and entrained air into the separation chamber. Air is separated and expelled through pump discharge while liquid recirculates into the lower volute.

Once air is completely removed from suction and liquid fills the impeller eye, the pump is fully primed and functions as a conventional centrifugal pump with both volutes performing as discharges.

The casing is designed so that an adequate volume of liquid for repriming is always retained in the pump, even if liquid is allowed to drain back to the source of supply from discharge and suction.

3796.5C

3796.5D

PRIMING PUMPING

Page 4: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

4 3796 i-FRAME™

3796 i-FRAMESealing Solutions Goulds engineered seal chambers are designed to accept a wide range of sealing arrangements to meet specific user requirements. Your Goulds representative will gladly recommend the best sealing solution for your service... some of which are illustrated here. Conventional Double Seal (with BigBore® Seal Chamber) • Liquids not compatible with single seal • Toxic, hazardous, abrasive, corrosive • When pump is operating under cavitation or low flows • Meet environmental regulations Double Cartridge Seal (with BigBore® Seal Chamber) • Same applications as conventional double seal • Reduced maintenance costs • No seal setting errors

Single Inside Seal (with BigBore® Seal Chamber) • Non-corrosive to moderate corrosive liquids • Moderate abrasives • Liquids that have good lubrication qualities Single Cartridge Seal (with TaperBore® PLUS Seal Chamber) • Same application as conventional single seal • Ease of maintenance • No seal setting problems Double Gas Barrier Seal (with BigBore® Seal Chamber for Gas Seals) • Toxic or hazardous liquids • Meet environmental regulations • When use of seal pot or external flush is not desirable • When compatible seal flush liquid not available

100% PMS 5415

60% PMS 5415

30% PMS 5415

100% PMS ProcBlue

100% PMS 185

100% PMS 157

100% PMS 156

100% PMS ProcYellow

100% PMS 151

10% Black

9b

100% PMS 5415

60% PMS 5415

30% PMS 5415

100% PMS ProcBlue

100% PMS 185

100% PMS 157

100% PMS 156

100% PMS ProcYellow

100% PMS 151

10% Black

9d

100% PMS 5415

60% PMS 5415

30% PMS 5415

100% PMS ProcBlue

100% PMS 185

100% PMS 157

100% PMS 156

100% PMS ProcYellow

100% PMS 151

10% Black

9a

100% PMS 5415

60% PMS 5415

30% PMS 5415

100% PMS ProcBlue

100% PMS 185

100% PMS 157

100% PMS 156

100% PMS ProcYellow

100% PMS 151

10% Black

9e

Page 5: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

Bonus Interchangeabilityi-FRAME Power Ends Fit 7 Different Process Pumps Minimize inventory, reduce downtime.

CV 3196 i-FRAMENon-ClogProcess Pumps

3196 i-FRAMEProcess Pumps

HT 3196 i-FRAMEHigh TemperatureProcess Pumps

LF 3196 i-FRAMELow Flow ANSIProcess Pumps

3198 i-FRAMEPTFE-LinedProcess Pumps

3796 i-FRAMESelf-PrimingProcess Pumps

NM 3196 i-FRAMENon-MetallicProcess Pumps

3796 i-FRAME™ 5

Page 6: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

Options

6 3796 i-FRAME™

i-ALERT®2 Equipment Health Monitor

What it Does: Monitor Tracks vibration, temperature & run-time hours 24/7/365.

Alarm Checks every five minutes & alarms if equipment is outside normal operating conditions.

Trend Stores data once per hour & on alarm for 30 days. Stores the weekly average, minimum & maximum up to 5 years.

Analyze Diagnose machine faults with vibration tools Fast Fourier Transform (FFT) & Time Wave Form Analysis.

Environment Rated for any industrial environment. IP67 water & dust resistant. Intrinsically Safe with a 3-year battery life (use dependent).

Wireless Sync data via Bluetooth Smart enabled smartphones and tablets.

i-ALERT®2 Equipment Health Monitor

How it Works: 1. ACTIVATE The i-ALERT devices are light activated by removing the sticker. The i-ALERT® device begins wirelessly broadcasting once activated.

2. AUTO CONFIGURATION The i-ALERT2 device averages the vibration over 25 hours of run-time and sets the alarm levels to 2 x average (0.1-1.5ips minimum). Temperature alarm default to 80°C (176°F) OR

2. MANUAL CONFIGURATION User manually sets the alarm thresholds via the i-ALERT® mobile application.

3. Monitor The i-ALERT device checks every 5 minutes. If two consecutive readings are above alarm threshold the i-ALERT device will go into alarm.

Spend less time collecting data and more time fixing problems. The i-ALERT®2 mobile app has the ability to scan multiple i-ALERT®2 devices within range to quickly and safely inspect multiple machines.

Dashboard Simple, intuitive dashboard to track vibration, temperature,

run-time & battery life.

Trending Trend vibration,

temperature, & kurtosis to monitor any changes in the

equipment operation.

BOM Load the as built of

materials based on the pump serial number.

Page 7: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAME™ 7

Hydraulic Coverage

0

150

125

100

75

50

25

m m

FT.

TOTA

L H

EAD

—35

00 R

PM (

60 H

z)

CAPACITY—3500 RPM (60 Hz)

TOTA

L H

EAD

—28

50 R

PM (

50 H

z)

CAPACITY—2850 RPM (50 Hz)0

0 200100 300 400 500

20 40 60 80 100m /h3

GPM

0 600500400300200100

0 14012010080604020

GPM0

100

300

200

100

75

50

25

00

500

400

300

200

100

FT.

m /h3

3796 A

3500/2850 RPM

2x2-10 4x4-10

3x3-10

11/2x11/2-8

1x11/2-6

0

5

10

15

20

25

30

40

50

60m mFT.

TOTA

L H

EAD

—17

50 R

PM (

60 H

z)

CAPACITY—1750 RPM (60 Hz)

TOTA

L H

EAD

—14

50 R

PM (

50 H

z)

CAPACITY—1450 RPM (50 Hz)0

0 50 100 150 200 300 400 500 600 800 1000 1400

10 20 30 40 60 80 100 120 140 200 300

= Scale Change

m /h3

GPM

0 80070060050040030020015010050 1000 1400 1800

0 20 40 80 120 140 200 300

GPM0

10

20

30

40

50

60

70

90

110

130 40

30

20

15

10

5

00

90

80

70

60

50

40

30

20

10

FT.180

160

140

120

100▼

▼m /h3

3796 B

1750/1450 RPM

3x3-13

2x2-10 3x3-10

4x4-10

6x6-134x4-13

11/2x11/2-8

1x11/2-6

Page 8: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAMESelf-Priming Process Pumps

8 3796 i-FRAME™

i-ALERT® CONDITION MONITOR Constantly measures vibration and temperature at the thrust bearing. Colored LED’s indicate general pump health. Provides early warning of improper operation before catastrophic failure occurs. (i-ALERT®2 Bluetooth Equipment Health Monitor option available. See page 16 for more information.)

CONTINUOUS PERFORMANCE Original flow, pressure and efficiency are maintained by simple external adjustment resulting in long-term energy and repair parts savings.

INPRO VBXX-D HYBRID LABYRINTH SEALS Prevents premature bearing failure causedby lubricant contamination or loss of oil.Stainless steel rotors for optimal performance in corrosive environments.

PREMIUM SEVERE-DUTY THRUST BEARINGS Increase bearing fatigue life by 2-5X that of conventional bearing steels.

HEAVY DUTY SHAFT & BEARINGS Rigid shaft designed for minimum deflection at seal faces — less than 0.002 in. (.05 mm).Bearings sized for 10-year average life under tough operating conditions. Available with or without shaft sleeve.

OPTIMIZED OIL SUMP DESIGN Increased oil capacity provides better heat transfer for reduced oil temperature. Bearings run cooler and last longer. Contaminants directed away from bearings to magnetic drain plug.

ONE-INCH BULL’S EYE SIGHT GLASS Assures proper oil level critical to bearing life.Can be mounted on either side of pump for installation flexibility.

i-FRAME POWER END Designed for reliability and extended pump life, backed with a 5-year warranty.

MAGNETIC DRAIN PLUG Standard magnetic drain plug helpsprotect bearings and prolong life.

Page 9: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAME™ 9

DUCTILE IRON FRAME ADAPTER Material strength equal to carbon steel for safety.

COMPACT, ON E-PIECE CASING DESIGN Eliminates need for separate priming chamber, air separator or valves. Self-venting, centerline discharge. Back pull-out design.

SERRATED FLANGES For positive sealing against leakage.Meets ANSI B16.5 requirements. Class 150 FF flanges standard, optional class 150 RF.

FULLY OPEN IMPELLER Acknowledged best design forCPI services — solids handling, stringy material, corrosives, abrasives. Back pump-out vanes minimizeseal chamber pressure.

OPTIONAL CASING DRAIN

Page 10: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

10 3796 i-FRAME

Sectional View

761B 168 333A 108 418

496

112

136

122

332A

319

228

469B

250 184M 351

100

101

358A

Page 11: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAME 11

3796 i-FRAME

*E.I. DuPont reg. trademark **LTi Power End features Duplex Angular Contact ***Integral with STi frame

Parts List and Materials of Construction

Construction Details All dimensions in inches and (mm).

Page 12: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

12 3796 i-FRAME

Goulds Patented i-FRAME™ Power EndsExtended Pump Life Through Intelligent Design Goulds i-Frame™ Power Ends are the result of 160 years of design experience, customer interaction, and continuous improvement. Customers get extended Mean Time Between Failure (MTBF) and lower life cycle costs (LCC) ... guaranteed!

0

10

GRP I

Oil

Sum

p Ca

paci

ty–(

oz)

GRP II GRP II GRP III

20 GOULDS Industry Average

30

40

50

60

70

80

90

100 POWER END OIL CAPACITY vs. ANSI Pump Average

Larger Means Cooler

Patented i-ALERT® Condition Monitor The heart of the i-Frame, the i-ALERT® condition monitor unit continuously measures vibration and temperature at the thrust bearing and automatically indicates when pre-set levels of vibration and temperature have been exceeded, so that changes to the process or machine can be made before failure occurs. A visual indication of pump health makes walk-around inspections more efficient and accurate. The result is a more robust process to monitor and maintain all your ANSI pumps so that your plant profitability is maximized. (i-ALERT®2 Bluetooth Equipment Health Monitor option available. See page 16 for more information.)

1 2 3 4 5 6 7 8 9 10

0 0 : 0 0 0 0 : 8 1 0 0 : 2 1 0 0 : 6 0 0 0 : 0 0

frequency (Hz)

time

onset of damage

damaged

seve

rity

seve

rity

H

ealth

Time

Failure

Misalignment

Failures can happen between monitoring intervals

Onset of failuregoes undetected

Normal monitoringinterval

?

A reliability program centered around walk-arounds captures equipment condition on average once a month; the failure process, however, can begin and end quite frequently within this time period.

Inpro VBXX-D Hybrid Bearing IsolatorsMost bearings fail before reaching their potential life. They fail for a variety of reasons, including contamination of the lubricant. INPRO VBXX-D has long been considered the industry standard in bearing lubricant protection. The i-FRAME™ now improves upon that design by offering stainless steel rotors, for maximum protection against contaminants and the corrosive effects of seal leakage or environmental conditions. These seals are non-contacting and do not wear.

Optimized Oil Sump Design

SingleLip Seal

MagneticSeal

BearingLowerRange

BearingUpperRange

Labyrinth

Infinite60

50

40

30

20

10

0

Des

ign

Life

, X 1

000h

Relative Life of Bearing Housing Protection Devices

Internal sump geometry is optimized for longer bearing life. Sump size increased by 10%-20% results in better heat transfer and cooler bearings. Contoured design directs contaminants away from bearings, to the magnetic drain plug for safe removal.

0

10

GRP I

Oil

Sum

p Ca

paci

ty–(

oz)

GRP II GRP II GRP III

20 GOULDS Industry Average

30

40

50

60

70

80

90

100 POWER END OIL CAPACITY vs. ANSI Pump Average

Larger Means Cooler

1

2

1

2

3

4

5

3

Page 13: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAME 13

2XXLIFE, HOURS

PERC

ENT

FAIL

ED, %

1

5

StandardBearing Steel

10

50

909599

99.9

Hour

s

Competitor

BEARING LIFE CALCULATION

55WARRANTYYEARYEAR

Shaft and Bearings Engineered for Maximum Reliability

Every 3196 i-Frame™ Power End is engineered and manufactured for optimal pump performance and increased MTBF.

Fatigue life more than double that of conventional bearing steels.

The rugged shaft and bearing combination maintains shaft deflection of less than 0.002 inches at all operating points. The result is longer seal and bearing life.

Premium severe-duty thrust bearings increase bearing fatigue life by 2-5X.

• High purity steels have fewer inclusions than standard steel− better grain structure and wear resistance.

• Heat treatment of bearing elements increases hardness for increased fatigue life.

Forty-degree contact angle on the MTi thrust bearing for higher thrust load capability.

• 35% higher dynamic load rating vs. major competitor.

• Increases L’10 bearing life 2X.

LTi Power End for High Load Applications

Increased L’10 Bearing Life 150% to 200% on the Toughest Applications

Ideal for tough conditions when a power end is pushed beyond ANSI limits; operating at low flows and higher heads, pumping high specific gravity liquids, fluctuating process conditions, overhung belt drive.

Oversized shaft and bearing assembly significantly expands the limits for long, trouble-free bearing and seal life. On high load applications, the LTi power end improves bearing life 150% - 200%; oil operating temperature reduced by 45°F (25°).

Duplex thrust bearings (40°/40° angular contact) with machined brass cages, are ideally sized for high load applications.

Duplex thrust bearings (40° / 40° angular contact) with machined brass cages, are ideally sized for high load applications.

Flinger/channel oil lubrication system provides 30% increased L’10 life; 15°F (8°C) reduced oil temperature.

Our GuaranteeWe are so confident that the i-FRAME is the most reliable Power End in the industry, that we are proud to offer a standard 5-year warranty on every i-FRAME™ ANSI Process Pump.

4

5

Page 14: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

14 3796 i-FRAME

Dimensions

Baseplate Mounting Options

All dimensions in inches and (mm). Not to be used for construction.

SUCTION DISCHARGEA B

E

D

X

33/4(95)

3796

Goulds offers a complete range of mounting systems to meet plant reliability requirements, and to make alignment and maintenance easier.

CAMBER TOP CAST IRONRigid and corrosion resistant, it is preferred by many plants.

CHEMBASE PLUS™Polymer concrete construction provides exceptional rigidity & corrosion resistance. ANSI 1991 dimensional.

FABRICATED STEELEconomical baseplate that meets ANSI/ASME B73.1 M current edition dimensional requirements.

ENHANCED FEATURE FABRICATED STEELUpgraded ANSI baseplate designed to maximize pump operation life and ease installation by meeting API-minded chemical pump users toughest requirements.

Page 15: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

3796 i-FRAME 15

Page 16: 3796 i-FRAME - Goulds Pumps · 3796 i-FRAME Self-Priming Process Pumps NM 3196 i-FRAME Non-Metallic Process Pumps 3796 i-FRAME™ 5. Options 6 3796 i-FRAME

Manufacturing/Assembly/Packaging

Direct Sales Offices

Service Centers (ITT)

Distribution Center

Visit our website at www.gouldspumps.com

240 Fall StreetSeneca Falls, NY 13148www.itt.com

B.3796.en-US.2017-06© 2017 ITT Corporation, Inc.

Wherever you are,we’re there too.

Reliability has no quitting time.Building on over 160 years of Goulds Pumps experience, PRO Services provides an array of services focused on reducing equipment total cost of ownership (TCO) and increasing plant output, including predictive monitoring, maintenance contracts, field service, engineered upgrades, inventory management, and overhauls for pumps and other rotating equipment.

Your Total Solution For Equipment Life Cycle Optimization

Control Solutions(PumpSmart)

Power Ends

Field Services

Training

Monitoring Solutions(ProSmart)

On-board Continuous Monitoring (i-Alert)

Reliability Engineering Pump Parts

Goulds Pumps/Bornemann

Energy Performance Services

Inventory Management

Rotating Equipment Repairs

Engineered Parts(ProCast)

Pump Upgrades

Pump Root Cause Analysis

Pump Replacements

Design & Sourcing

Part

s &

Inve

nt

ory

Operation Performance