320 amp continuous 400 amp max - kirby...
TRANSCRIPT
320 AMP CONTINUOUS-4 TERMINAL-JAW CLAMPING LEVER-RINGLESS-600 VAC
320 AMP CONTINUOUS400 AMP MAX
' 1 ;3)
@©C3y@24482124
U2124-X U2448-X
320 AMP-4 TERMINAL-SIDE WIREWAY-RINGLESS-103W
SERVICE
OH/UG
UG
CATALOGNUMBER
U2448-X
*U2124-X
HUB
C.P.
C.P.
CONNECTORSCU/AL
LINE
3/8"-16STUD
3/8"-16STUD
LOAD
3/8"-16STUD
3/8"-16STUD
FFTHTERM.KTTB
K3865
K3865
BY-R4SS
LEVER
LEVER
DIMENSIONS
D"
61/2
53/4
W"
173/4
16
H
341/s
30
CONCENTRIC K.O.'S
1
—
3'/2
2
3
31/2
3
4
4
4
1/4
1/4
5
V/4,1
—
6
—
V/4,1
HUBS: For proper hub selection see the hub suffix chart on the accessory page.BYPASS: The lever supplies clamping action on meter spades and also operates bypass device.CONNECTORS: Stud type units supplied with 3/8"-16 hex head nuts with Belleville washers. For connector kits, order as extra:K1539 (350kcmil) or K1540 (BOOkcmil). For twin lug connectors order as extra: K1350 (350kcmil). Separate kits are requiredfor both line and load.FIFTH TERMINAL: For factory installed fifth terminal in the 6 o'clock position add the suffix "-5T6" to the catalog number. Forfactory installed fifth terminal in the 9 o'clock position at the suffix "-5T9" to the catalog number.
* For the same unit with anti-inversion feature order catalog number U1915-X.
fll MILBANK20
M E T E R S O C K E T A C C E S S O R I E S
INTERCHANGEABLE UNIT HUBS
REMOVABLE HUBCLOSING PLATE
SMALL"RL"OPENING (STANDARD)
LARGE "R"OPENING (HEAVY DUTY)
SIZE
STANDARD(for -RL opening)
LARGE(for -R opening)
SUFFIX
-XL
-X
CAT. #
A7551
S9064
SUFFIX
-WL-YL-ZL-DL-EL
SIZE
1"
1 V/'
1 V?"2"
21/2"
MILBANKNO.
A7514A7515A7516A7517A7518
I
SUFFIX
-F-G-H
SIZE
3"
3'2"
4"
MILBANKNO.
A8110
A8111A8112
' ID Oil
HUB ADAPTER PLATE(Converts -R opening to -RL)
S8324
HUB SUFFIX CHART
CLOSING COVERS
•\ /
ORLR
XLX
RXL
RRL
Plain TopSmall Hub OpeningLarge Hub OpeningSmall Closing PlateLarge Closing PlateLarge Hub Opening
adapted to small Closing Plate
Large Hub Openingadapted to small Hub Opening
WLYLZLDLEL
F
G
H
1"1 V/'
1V2"
2"2'/2"
3"
3V
4"
For -RL OpeningFor -RL OpeningFor -RL OpeningFor -RL OpeningFor -RL Opening
For -R Opening
For -R Opening
For -R Opening
METER CLOSING PLATE(Gray Plastic)
6003
METAL CLOSING PLATE(For ringless sockets)
CP-21
METER CLOSING PLATE(Clear Plastic)
6116 GO
HUBS FOR SWITCHES
CATALOGNUMBER
SH75
SH100
SH125
SH150
SIZE
y4"1"
1 v:1 1/2"
CATALOGNUMBER
LH125
LH150
LH200
LH250
SIZE
1 v:1 1/2"2"
2 1/2"
SINGLE
SINGLE CONNECTOR KITS
BREAKER MOUNTING CLIP(for RV/MH pedestals)
K3785
CONNECTOR KITS
For use with 3/8"-16 studtype units only
SUFFIX
-K1-K3
SUFFIX
-K5-K7
CATALOG #
K1539K1540
CATALOG #
K3082K3441
(3 per set) - 1 0
350 kcmil (MAX)600 kcmil (MAX)
(4 per set) - 3 0
350 kcmil (MAX)600 kcmil (MAX)
fll MILBANK
TWIN
TWIN CONNECTOR KITS
SUFFIX
-K2-K4
SUFFIX
-K6-K8
CATALOG #
K1350K1541
CATALOG #
K3442K3083
(3 per set) - 1 0
350 kcmil (MAX)600 kcmil (MAX)
(4 per set) -30
350 kcmil (MAX)600 kcmil (MAX)
63
P R O D U C T S P E C I F I C A T I O N S
ENCLOSURE INFORMATION
MILBANK ELECTRICAL METER ENCLOSURESSPECIFICATION NOTE
All Milbank electrical enclosures in this catalog are rated "Type 3R Electrical Enclosure" unless specified otherwise onpage (Type 1 switches are listed on page 8.) All enclosures with a U/L designation are constructed per the appropriateU/L standard and may be installed per the National Electric Code. Meter sockets are constructed per "UL 414, MeterSockets," file #E30202 and per "ANSI C12.7-1993-Meter Sockets." All test switches are constructed per "UL414, MeterSockets," file # E30202 and per "ANSI C12.9-1993-Test Switches." Power outlets are constructed per "UL 231, PowerOutlets," file # E90945. Panelboards are constructed per "UL 67, Panelboards," file # E32628 and "NEMA PB-1-1984-Panelboards." Pullout switches are constructed per "UL 1429, Pullout Switches," file # 133062.
DEFINITIONS PERTAINING TO NONHAZARDOUS LOCATIONS
INDOOR USE
TYPE 1 ENCLOSURE:Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against limited
amounts of falling dirt.
TYPE 12 ENCLOSURE:Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against circulating
dust, falling dirt and dripping noncorrosive liquids.
TYPE 13 ENCLOSURE:Type 13 enclosures are intended for indoor use primarily to provide a degree of protection against dust,
spraying of water, oil, and noncorrosive coolant.
OUTDOOR USE
TYPE 3 ENCLOSURE:Type 3 enclosures are intended for outdoor use primarily to provide a degree of protection against rain,
sleet, windblown dust, and damage from external ice formation.
TYPE 3R ENCLOSURE:Type 3R enclosures are intended for outdoor use primarily to provide a degree of protection against rain,
sleet, and damage from external ice formation.
TYPE 4 ENCLOSURE:Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against
wind-blown dust and rain, splashing water, hose-directed water, and damage from external ice formation.
TYPE 4X ENCLOSURE:Type 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection
against corrosion, wind-blown dust and rain, splashing water, hose-directed water, and damage from external ice for-mation.
fill MILBANK71