Page 1: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

2X800 MW, YERMARUSHIGH PRESSURE HT COMPLETED

ON 25.09.2015 IN THE PRESENCE OF

JOINT DIRECTOR OF BOILERS KARNATAKA

Page 2: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

POOJA PERFORMED BY JDB & TEAM

Shri. T G Manjunatha

JDB Karnataka

Shri. Sundara Rajan

AGM Site Incharge

Shri. Parimala Jana AGM

Shri. Venugopal SE, RPCL

Shri. S SridharAGM

Page 3: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE HIGHEST PRESSURE - BFD HT

HT PRESSURE 675 kg/cm2

Page 4: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE BFD HT (INCLUDING HEATERS) HT PRESSURE 525 kg/cm2

Page 5: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

EXTRACTION 3,4 & 8 HT

HT PRESSURE 142.5 kg/cm2

HT PRESSURE 10.5 kg/cm2

Page 6: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

TESTED CIRCUITSUNIT#1BFD FROM PUMP TO HP HEATERS &

RECIRCULATIONBFD FROM HP HEATER TO BOILER TPEXTRACTIONS 3,4,5,6 & 8AUX STEAM HFO HEATING AND ATOMISING

LINESUNIT#2 CRH FROM NRV TO BOILER TP INCLUDING HPBP

DOWNSTEAM TO CRH, CRH TO DEAERATOR, EXTRACTION FROM CRH TO TDBFP A&B, CRH TO PRDS, EXTRACTION FROM CRH TO HPH -7A & 7B.

Page 7: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE PROTOCOLS

Page 8: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE PROTOCOLS

Page 9: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE

PROTOCOLS

Page 10: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE

PROTOCOLS

Page 11: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE

PROTOCOLS

Page 12: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THE PROTOCOLS

Page 13: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

RECORD BREAKYERMARUS TEAM HAS ACHIEVED A

RECORD COMPLETION OF HT FOR MORE THAN 10 CIRCUITS CONSECUTIVELY FOR SECOND TIME

HYDRO TEST COMPLETION OF 16 NOS. OF CIRCUITS ON 25-09-2015.

HYDRO TEST COMPLETION OF 12 NOS. OF CIRCUITS ON 10-08-2015.

BREAK A RECORD

Page 14: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

TEAM MEMBERS (JDB/BHEL/RPCL/STEAG/ICPL)

Page 15: 2X800 MW, YERMARUS HIGH PRESSURE HT COMPLETED ON 25.09.2015 IN THE PRESENCE OF JOINT DIRECTOR OF BOILERS KARNATAKA

THANK YOU