2665 s01-s04 ver 05
TRANSCRIPT
MEMBER SCHEDULE (for one site)
MARK DESCRIPTION QTY REMARKS
1 Ø 273.1 x 9.3 CHS 1 C350
2 Ø 152.4 x 6.0 CHS 1 C250
3
13-16011-018 Steel Cap Assembly (PM6-A,PM8-A)
1 SET CLENERGY
4
13-16011-019 Adjustable Tube 100x50x576 (PM6-A, PM8-A)
1 CLENERGY
5
13-15011-019 Main Tube 100x100x1900 (PM6-A)
1 CLENERGY
6
13-15011-037 Landscape Tube 70x70x2600 (PM6-A,PM8-A)
3 CLENERGY
7 13-10015-072 Standard Rail 3150 4 CLENERGY
8 PV MODULE Size 1650x992 6
9
13-110011-004 End Clamp 40mm
8 CLENERGY
10
13-11010-004 Inter Clamp 40mm
12 CLENERGY
11
13-16011-027 Accessory Pacakage (PM6-A, PM8-A)
1 CLENERGY
1
2
3
5
6
7
8
Ø 750 Bored Pier
Footing f'c=32 MPa
With 150 kPa Min.
End Bearing Pressure
DateAmendmentIssue
Project:
Rev.
Date:
A3 Scale:
Drawn:
Job No:
Plot Date:
APPROVEDDRAWING No
Designed:
Sheet No.
Client:
CCopyright
Title:
2665 S01-S04 Ver 05.dwg
CHECKED
By
S01
CUSTOM DESIGNED POST MOUNTED
SOLAR PANEL SUPPORTS. 4 LOCATIONS
@ Mt KOSCIUSKO NATIONAL PARK
REGAL ELECTRO
SEPT'16
AS SHOWN
K.Z
S.P
1 OF 4
2665 C4
ELEVATION & MEMBER SCHEDULE
M.A M.A
49
10
ELEVATION
SCALE = 1:50
ALL STEEL WORKS EXPOSED TO THE
WEATHER SHALL BE HOT DIP GALVANIZING
AT THE RATE OF 0.6 - 0.7 Kg/m² UNLESS
OTHER WISE NOTED
NOTE:
IN WINTER THE PANEL ANGLE MUST BE
ADJUSTED TO 60° TO AVOID SNOW LOADING
ON PANELS & RAIL COMPONENTS.
DateAmendmentIssue
Project:
Rev.
Date:
A3 Scale:
Drawn:
Job No:
Plot Date:
APPROVEDDRAWING No
Designed:
Sheet No.
Client:
CCopyright
Title:
2665 S01-S04 Ver 05.dwg
CHECKED
By
S02
CUSTOM DESIGNED POST MOUNTED
SOLAR PANEL SUPPORTS. 4 LOCATIONS
@ Mt KOSCIUSKO NATIONAL PARK
REGAL ELECTRO
SEPT'16
AS SHOWN
K.Z
S.P
2 OF 4
2665 C3
DETAIL ELEVATION & 3D VIEW
M.A M.A
D1
S03
D2
S03
1
2
3
5
6
7
8
4
9
10
11
2
5
8
7
6
3
3D VIEW
SCALE = 1:20
DETAIL ELEVATION
SCALE = 1:20
DateAmendmentIssue
Project:
Rev.
Date:
A3 Scale:
Drawn:
Job No:
Plot Date:
APPROVEDDRAWING No
Designed:
Sheet No.
Client:
CCopyright
Title:
2665 S01-S04 Ver 05.dwg
CHECKED
By
S03
CUSTOM DESIGNED POST MOUNTED
SOLAR PANEL SUPPORTS. 4 LOCATIONS
@ Mt KOSCIUSKO NATIONAL PARK
REGAL ELECTRO
SEPT'16
AS SHOWN
K.Z
S.P
3 OF 4
2665 C4
SECTION DETAILS
M.A M.A
DETAIL
SCALE = 1:5
D1
S02
2
1
1
DETAIL
SCALE = 1:5
D2
S02
A A
B B
SECTION
SCALE = 1:5
AA
-
SECTION
SCALE = 1:5
BB
-
1
2
8
8
8
1
3
2
BASE PLATE
SCALE = 1:10
8
8
DateAmendmentIssue
Project:
Rev.
Date:
A3 Scale:
Drawn:
Job No:
Plot Date:
APPROVEDDRAWING No
Designed:
Sheet No.
Client:
CCopyright
Title:
2665 S01-S04 Ver 05.dwg
CHECKED
By
S04
CUSTOM DESIGNED POST MOUNTED
SOLAR PANEL SUPPORTS. 4 LOCATIONS
@ Mt KOSCIUSKO NATIONAL PARK
REGAL ELECTRO
SEPT'16
AS SHOWN
K.Z
S.P
4 OF 4
2665 C2
M.A M.A
ELEVATION
SCALE = 1:50
ALL STEEL WORKS EXPOSED TO THE
WEATHER SHALL BE HOT DIP GALVANIZING
AT THE RATE OF 0.6 - 0.7 Kg/m² UNLESS
OTHER WISE NOTED
NOTE:
IN WINTER THE PANEL ANGLE MUST BE
ADJUSTED TO 60° TO AVOID SNOW LOADING
ON PANELS & RAIL COMPONENTS.
1
2
3
5
6
7
8
4
9
10
PLAN
SCALE = 1:50
SECTION
SCALE = 1:20
CC
-
CC
1