24-ot-led project name ot-led 2x4 led recessed troffer ... · led recessed troffer series...

5
Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. www.iuseelite.com By Elite Lighting EMERGENCY LUMENS DIMMING & CONTROL CCT & DYNAMIC PLATFORMS COLOR QUALITY SIZE MOUNTING CRI LIFETIME PHOTOMETRIC TESTS NOMINAL LUMENS DELIVERED LUMENS WATTAGE 10000 8952 71 W 8000 8572 67 W 7000 7089 56 W 6000 5812 46 W 5000 5475 36 W 5000, 6000, 7000, 8000, 10000 10W - Up to 1000L output (Bodine BSL310) 20W - Up to 2000L output (Bodine BSL20) 0-10V Flicker Free 1% Dimming Standard (DIM10), LUTH, LUT2W, DIMST, ELDO10.1, ELDODMX.1, DALI.1 30K, 35K, 40K, 50K 3 Step MacAdam Ellipse 2’x2’, 2’x4’, 1’x4’ Recessed 85+ L70 at 50,000 Hours In Accordance with IES LM79-08, LM80 and TM-30, TM-21 24-OT-LED 2’x4’ Based on 4000K, 85+ CRI. Actual wattage may vary +/- 5% 2 X 4 Foot LED Recessed Troffer Luminaire 3-3/4" 23-3/4" 48" L FEATURES The OT-LED blends the traditional look of an architectural volumetric troffer with a center acrylic diffuser, resulting in unmatched optical performance that delivers the latest in LED technology and lens innovation. The integrated LEDs are strategically angled behind the center indirect acrylic diffuser to maximize lumen output and provide even illumination across the full face of the luminaire. The consistency of the volumetric effect results in optimized visual comfort, enhancing the quality of illumination. The combination of energy savings and optical performance creates the ideal choice for educational, medical, office and retail spaces.

Upload: others

Post on 13-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m

By Elite Lighting

EMERGENCY

LUMENS

DIMMING & CONTROL

CCT & DYNAMICPLATFORMS

COLOR QUALITY

SIZE

MOUNTING

CRI

LIFETIME

PHOTOMETRIC TESTS

NOMINAL LUMENS DELIVERED LUMENS WATTAGE

10000 8952 71 W

8000 8572 67 W

7000 7089 56 W

6000 5812 46 W

5000 5475 36 W

5000, 6000, 7000, 8000, 10000

10W - Up to 1000L output (Bodine BSL310)20W - Up to 2000L output (Bodine BSL20)

0-10V Flicker Free 1% Dimming Standard (DIM10), LUTH, LUT2W, DIMST, ELDO10.1, ELDODMX.1, DALI.1

30K, 35K, 40K, 50K

3 Step MacAdam Ellipse

2’x2’, 2’x4’, 1’x4’

Recessed

85+

L70 at 50,000 Hours

In Accordance with IES LM79-08, LM80 and TM-30, TM-21

24-OT-LED 2’x4’

Based on 4000K, 85+ CRI. Actual wattage may vary +/- 5%

2 X 4 Foot LED Recessed Troffer Luminaire

WWW.ORACLELIGHTING.COM60 Oracle by Elite Lighting

LED Recessed Tro

r Luminaire

OT2' X 4’LED

OT-LED 2X4 LED RECESSED TROFFER LUMINAIRE

LED RECESSED TROFFER SERIES

3-3/4"

23-3/4"

48"

SERIES

FIXTURE SIZE24 - 2’ X 4’

Ordering Information: Example:

CCT30K35K40K50K

- (3000K)- (3500K)- (4000K)- (5000K)

TYPELED

SERIESOT-Oracle

Troffer

OPTICS - The OT-LED uses a prismatic acrylic lens to scatter the light emitted from the LED chips into functional light. The LED offered in the OT-LED has the highest return on initial investment compared to other standard lighting solutions. Lens is attached to a door frame which is easily pivoted and removable without the use of tools.

DURABILITY - Our heavy-duty 20-gauge steel housing is engineered for maximum strength and extended life. Corners interlock to prevent aesthetic damage to the fixture. Sides and corners are uniformly turned in and hemmed to remove sharp edges for safe handling and easy installation.

PERFORMANCE - The OT-LED powered lighting technologies offer a higher return on investment than any other lighting technology. The light engines found in the OT-LED are rated at 85+ CRI and available in multiple CCTs: 3000K, 3500K, 4000K and 5000K. All LEDs and LED fixtures are rated and tested to LM-79 and LM-80 standards. The LEDs are also binned to a 3-step MacAdam ellipses to achieve consistent color from fixture to fixture.

THERMAL MANAGEMENT - LED light engines are attached directly to the housing which keeps the engines cool. Our advanced thermal management system allows the light output of the LED engines to be maintained at 70% of initial lumens at 83,000 hours of operation.

MAINTENANCE - LED engines and driver can be accessed through the bottom by removing hinged door frame and driver box cover. LED engines are removable and upgradable even after fixture installation. Fixture can be regularly and safely wiped down to ensure optimal fixture performance.

ELECTRICAL - Powered by high-quality constant-current power LED drivers which are rated for 50 to 60Hz at 120-277V input, produce less than 20% THD, and have a power factor of .90 to 1.00.

DIMMING - The OT-LED comes standard with DIM10, 0-10V dimming on either 120 or 277V. Dimmable down to 1% of initial lumens. Also available in Lutron dimming options. Consult factory for dimmer compatibility. LUTH - Lutron Hilume Dimming down to 1% compatible with 3 wire and EcoSystem Controls available on all fixtures up to 50 Watts. LUT2W - Lutron 2 Wire Dimming down to 1% compatible with 2 wire and Forward Phase Control Systems available on all fixtures up to 50 Watts. LUTFTB - Lutron Hilume Fade to Black Dimming down to 1% compatible with EcoSystem Controls available on all fixtures up to 75 Watts. DIMST - Step Dimming allows fixtures to be turned on at 100% o r 50% i s available for fixtures up to 50 Watts. ELDO1O.1 - EldoLED SoloDrive 0-10V. Dimming down to .1%. available on all fixtures up to 100 Watts. ELDODALI - EldoLED PowerDrive 0-10V. Dimming down to .1%. available on all fixtures up to 100 Watts. ELDODMX - EldoLED PowerDrive Dimming down to .1%. available on all fixtures up to 100 Watts. Please see EldoLED website for wiring diagrams and a list of compatible DMX and Dali control systems.

OPTIONS - Fixtures can be shipped pre-installed with daylight harvesting controls, occupancy sensors, and/or power pack. Available manufacturer options include Leviton, Wattstopper, Hubble Automation, and others.

QUALITY CONTROL - Every fixture is turned on and rigorously tested by our QC Department before shipping.

LISTING

WARRANTY - Limited 5 Year Warranty

PRODUCT FEATURES:• Mitered door frame prevents light leaks, and minimizes dust from entering fixture• Constructed of one-piece ribbed unitized housing and corners that interlock, preventing

damage to luminaire• Door frame is designed with cam latches and T hinges to secure frame to housing and allows

for easy lamp maintenance• Frosted 0.100” thick #12 pattern acrylic lens, standard• Housing and door frame interface provides a superior mechanical light seal• Post-painted with a 93% reflective white coat to improve fixture efficacy.• All sides and corners are turned in and hemmed, removing sharp edges for safe handling

and installation• Rated at 85+ CRI and available in multiple CCTs

• Life tested to ensure light output of L70 up to 83,000 hrs and L80 up to 50,000 hrs• Tested to LM-79 and LM-80 standards• LED lighting technology offers the highest return on initial investment over the lifetime of the

fixture• Emergency battery back-up comes pre-installed on the fixture and emergency push button is installed on the fixture for easy access and aesthetics.• Dimmable down to 1% with compatible dimming systems• LED light engine is completely removable and upgradable• Four corner tie points are standard for safety wire support when required and built-in

earthquake clips standard• Fits into standard T-bar sizes including 5/8th, 3/8th, and slot T• Same-day shipping on most options (Consult factory)

The OT-LED is a high-quality yet economical troffer luminaire powered by LED lighting technology which offers the highest return on initial investment over the lifetime of the fixture. An excellent highly efficient fixture, ideal for office spaces, schools, hospitals, and many other indoor locations. Compatible with most industry standard T-bar grids.

LUMENS5000L6000L

8000L

- (5530 lumens)- (5800 lumens)- (7100 lumens)- (8600 lumens)- (8950 lumens)

LUMENS5000

LUMENS6000

LUMENS7000

LUMENS

36WATT

46WATT

56WATT

68WATT

CRI85

EMERGENCYO-EMG-LED

83,000 HRS

L70LIFE TIME

C A LC U L AT E D

L80LIFE TIME

C A LC U L AT E D

50,000 HRS

VOLTAGEMVOLT347*

* Consult factory for details

LENSA12A19

A-SFW

- A12- A19- Smooth

Frosted White

OTHER OPTIONS24FK

C5FS-355

FBFSBFRIS

GDF24-FA-DF

USA

- Flange Kit for 2’ X 4’ Fixture- 6’ 4-wire Flex Cable (Double Circuit)- Line Voltage Motion Sensor- Line Voltage Microwave Sensor- HF Microwave Sensor 0-10 20% Dim- HF Microwave Sensor 0-10 50% Dim- Internal Fast Blow Fuse- Internal Slow-Blow Fuse- Radio Interference Suppressor- Gasketed Door Frame- Flushed Aluminum Door Frame- Made in America Compliance

DIMMING DIM10

* DIMST* LUTH

* LUT2WLUTFTB

ELDO10.1ELDODALIELDODMX

- 0-10V Dimming- Step Dimming- Lutron Hilume- Lutron 2Wire- Lutron Fade to Black- EldoLED 0-10V- EldoLED DALI- EldoLED DMX

* DIMST, LUTH and LUT2W dimming options are only available for the fixtures up to 5000 lumens.

defiilauq fo tsil roF ** DLC fixture, please consult factory

(On selected configuration, consult factory)

According toDLC Test Results

According toDLC Test Results

According toDLC Test Results

According toDLC Test Results

8000LUMENS

71WATT

According toDLC Test Results

10000

10000L

7000L

OSM3D-DDW-20OSM3D-DDW-50

OSM3D-V1W

Catalog Number 24-OT-LED

Project Name

Type

24 OT LED

FEATURESThe OT-LED blends the traditional look of an architectural volumetric troffer with a center acrylic diffuser, resulting in unmatched optical performance that delivers the latest in LED technology and lens innovation. The integrated LEDs are strategically angled behind the center indirect acrylic diffuser to maximize lumen output and provide even illumination across the full face of the luminaire. The consistency of the volumetric effect results in optimized visual comfort, enhancing the quality of illumination. The combination of energy savings and optical performance creates the ideal choice for educational, medical, office and retail spaces.

By Elite Lighting

Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m

24-OT-LED

Example: 24-OT-LED-5000L-DIM10-MVOLT-30K-85

FIXTURE SIZE24 - 2’ X4’

SERIESOT

VOLTAGEMVOLT

347*120277

EMERGENCYO-EMG-LED-10WO-EMG-LED-20W

CCT30K35K40K50K

TYPELED

LEDOT24

*Consult factory for details

LUMENS5000L 6000L7000L8000L

10000L

- 5000 lumens- 6000 lumens- 7000 lumens- 8000 lumens- 10000 lumens

DIMMINGDIM10DIMST

LUTHLUT2W

ELDO10.1DALI

ELDODMX

- 0-10V Dimming- Step Dimming- Lutron Hilume- Lutron 2Wire- EldoLED 0-10V- EldoLED DALI- EldoLED DMX

2’x4’

LUT2W are available in 120V only LUT2W up to 4000LLUTH, ELDO10-.1, ELDODALI-.1, and ELDODMX-.1 are available in 120V and 277V -Reference last page for Control Options

2 X 4 Foot LED Recessed Troffer Luminaire

CRI85

OTHER OPTIONS24FK

FBFSBFRIS

USA

24-FA-DF

FS-PPV2

FD-301

LMFC-011FS-205

- 2’x4’ Flange Kit- Internal Fast Blow Fuse- Internal Slow Blow Fuse- Radio Interference

Suppressor- Made in America

Compliance- Flushed Aluminum Door

Frame- Fixture Sensor Power

Pack- Low Voltage Daylight

Dimming Photosensor- Digital Lighting Manager- Low Voltage Pir Fixture Integrated Occupancy Sensor

*FD-301 & FS-205 require FS-PPV2- Power Pack

A12-A12(Standard)A19-A19A-SFW-Smooth Frosted WhiteA12-INV- Inverted Lens

MAINTENANCEThe center acrylic diffuser can be removed, allowing easy access to LED boards and driver compartment, locking into place for secure closure of the luminaire. LED engines and drivers are removable and upgradable even after luminare installation. Luminaire can be regularly and safely wiped down to ensure optimal performance.

OPTICAL SYSTEMThe The OT-LED uses a prismatic acrylic lens to scatter the light emitted from the LED chips into functional light. The LED offered in the OT-LED has the highest return on initial investment compared to other standard lighting solutions. Lens is attached to a door frame which is easily pivoted and removable without the use of tools.

CONSTRUCTIONBody is constructed of heavy-duty 20-gauge cold rolled steel gasketed, post-painted and engineered for maximum strength and extended life. All corners interlock to prevent aesthetic damage to the luminaire, with sides and corners uniformly turned in and hemmed to remove sharp edges for safe handling and easy installation. Luminaire is supplied with multiple wiring entrances for easy daisy chain of luminaires, to add power packs, whips, or other accessories in the field, or for continuous row mounting.

FINISHPost-painted with a 93% reflective white coat to improve luminaire efficacy, with all body components seamlessly interlocked for added structural strength.

MOUNTINGLuminaires accommodate lay-in ceilings, Slot T, and T-bar suspension systems for 5/8” and 3/8” ceiling thicknesses. Four corner tie points are standard for safety wire support when required, with built-in earthquake clips, standard. Luminaires may be available with flange kits, surface mounted kits, and other options.

OPTIONSLuminaires can be shipped pre-installed with whips, modular wiring systems, daylight harvesting controls, occupancy sensors, and/or power packs for individual or room control applications.

DRIVER ELECTRICAL INFORMATIONPowered by high-quality constant-current power LED drivers which are rated for 50 to 60Hz at 120/277V input. Available in 347V., produce less than 20% THD, and have a power factor of .90 to 1.00.

DIMMING & DRIVER INFORMATIONDIM10 - Flicker Free 1% Dimming Standard (DIM10) 0-10V dimming on either MVOLT 120, 277 or 347V. LUT2W - Lutron LTEA2W Hi-Lume 1%. 2-wire LED driver (120V forward phase only).LUTH - Lutron LDE1 Hi-Lume 1% EcoSystem LED driver with Soft-on, Fade-to-Black dimming technology.ELDO10.1 - EldoLED SoloDrive 0-10V. Dimming down to 0.1%. DALI - DALI DT6, DT8 dimming down to 1%. ELDODMX - EldoLED PowerDrive dimming down to 0.1%. Please see EldoLED website for wiring diagrams and a list of compatible DMX and DALI control systems. DIMST - Step Dimming

WARRANTYFive-year warranty for parts and components. (Labor not included)

LISTINGSc-UL-us - Listed for Feed Through Wiring.Listed for DLC, California Title 24 compliant.

By Elite Lighting

Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m

24-OT-LED 2’x4’2 X 4 Foot LED Recessed Troffer Luminaire

Zonal Lumens Summary

Zonal Lumens Summary

Zonal Lumens Summary

Zone Lumens %Lamp %Fixt

Zone Lumens %Lamp %Fixt

Zone Lumens %Lamp %Fixt

0-300

0-400

0-600

0-900

0-1800

0-300

0-400

0-600

0-900

0-1800

0-300

0-400

0-600

0-900

0-1800

1674.84 N.A. 30.602686.91 N.A. 49.104451.08 N.A. 81.305430.32 N.A. 99.205475.33 N.A. 100.00

1777.91 N.A. 30.602852.26 N.A. 49.104724.99 N.A. 81.305764.49 N.A. 99.205812.27 N.A. 100.00

2166.96 N.A. 30.603477.87 N.A. 49.105762.08 N.A. 81.307030.32 N.A. 99.207088.99 N.A. 100.00

Candle Power Distribution (Candelas)

Candle Power Distribution (Candelas)

Candle Power Distribution (Candelas)

RC - Ceiling Cavity Reflectance RW - Wall Reflectance

RC - Ceiling Cavity Reflectance RW - Wall Reflectance

RC - Ceiling Cavity Reflectance RW - Wall Reflectance

ROOM

CAV

ITY

RATI

ORO

OM C

AVIT

Y RA

TIO

ROOM

CAV

ITY

RATI

O

0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 991 109 104 100 96 106 102 98 95 98 95 92 94 91 89 90 88 86 842 100 92 85 80 97 90 84 79 86 81 77 83 78 75 80 76 73 713 91 81 73 67 89 79 72 66 76 70 65 73 68 64 71 66 63 604 84 72 64 57 81 71 63 57 68 61 56 66 60 55 64 59 54 525 77 65 56 50 75 64 56 49 61 54 49 59 53 48 58 52 48 466 72 59 50 44 70 58 49 43 56 48 43 54 48 43 52 47 42 407 66 53 45 39 65 53 44 39 51 44 38 49 43 38 48 42 38 368 62 49 41 35 60 48 40 35 47 40 34 45 39 34 44 38 34 329 58 45 37 31 57 44 37 31 43 36 31 42 36 31 41 35 31 2910 54 42 34 29 53 41 34 29 40 33 28 39 33 28 38 32 28 26

0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 991 109 104 100 96 106 102 98 95 98 95 92 94 91 89 90 88 86 842 100 92 85 80 97 90 84 79 86 81 77 83 78 75 80 76 73 713 91 81 73 67 89 79 72 66 76 70 65 73 68 64 71 66 63 604 84 72 64 57 81 71 63 57 68 61 56 66 60 55 64 59 54 525 77 65 56 50 75 64 56 49 61 54 49 59 53 48 58 52 48 466 72 59 50 44 70 58 49 43 56 48 43 54 48 43 52 47 42 407 66 53 45 39 65 53 44 39 51 44 38 49 43 38 48 42 38 368 62 49 41 35 60 48 40 35 47 40 34 45 39 34 44 38 34 329 58 45 37 31 57 44 37 31 43 36 31 42 36 31 41 35 31 2910 54 42 34 29 53 41 34 29 40 33 28 39 33 28 38 32 28 26

0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 991 109 104 100 96 106 102 98 95 98 95 92 94 91 89 90 88 86 842 100 92 85 80 97 90 84 79 86 81 77 83 78 75 80 76 73 713 91 81 73 67 89 79 72 66 76 70 65 73 68 64 71 66 63 604 84 72 64 57 81 71 63 57 68 61 56 66 60 55 64 59 54 525 77 65 56 50 75 64 56 49 61 54 49 59 53 48 58 52 48 466 72 59 50 44 70 58 49 43 56 48 43 54 48 43 52 47 42 407 66 53 45 39 65 52 44 39 51 44 38 49 43 38 48 42 38 368 62 49 41 35 60 48 40 35 47 40 34 45 39 34 44 38 34 329 58 45 37 31 57 44 37 31 43 36 31 42 36 31 41 35 31 2910 54 42 34 29 53 41 34 29 40 33 28 39 33 28 38 32 28 26

80%

80%

80%

70% 50% 30% 10%

70% 50% 30% 10%

70% 50% 30% 10%

70% 50% 30% 10%

70% 50% 30% 10%

70% 50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

0%

0%

0%

70%

70%

70%

50%

50%

50%

30%

30%

30%

10%

10%

10%

0%

0%

0%

RCRW

RCRW

RCRW

Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 20% = PF

Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 20% = PF

Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 20% = PF

05152535455565758590

05152535455565758590

05152535455565758590

2200.9842189.9512097.0501911.8651638.3191291.363

915.105571.125295.604100.264

7.735

2336.4292324.7182226.0992029.5181739.1381370.831

971.419606.271313.795106.434

8.211

2845.7752831.4642703.5632447.2112062.5141576.2701064.588

644.427364.365137.657

15.025

2200.9842184.7282081.9981884.5191590.2071228.718

847.210509.919267.385

85.4673.358

2336.4292319.1732210.1212000.4891688.0661304.332

899.346541.298283.840

90.7273.565

2845.7752833.8382717.2762474.6272110.4841647.0231153.329

709.487382.729147.568

26.016

2200.9842189.2052088.4681889.3781590.3621215.287

819.009495.859280.244102.339

5.533

2336.4292323.9262216.9892005.6481688.2301290.074

869.410526.373297.489108.636

5.873

2845.7752833.1822720.5572485.8402135.6611693.7971211.596

763.933399.452139.510

24.926

0

0

0

45

45

45

90

90

90

Candela Tabulation

Candela Tabulation

Candela Tabulation

Angle In Degrees

Angle In Degrees

Angle In Degrees

450

550

650

750

850

450

550

650

750

850

450

550

650

750

850

Average 00

Average 00

Average 00

2455 2336 23102145 1986 19191817 1622 15771535 1389 14561546 1318 1578

2606 2480 24522277 2108 20381928 1722 16741630 1474 15451642 1399 1676

2997 3131 32202495 2703 28392050 2257 24301892 1988 20752123 2276 2152

Average 450

Average 450

Average 450

Average 900

Average 900

Average 900

Luminance Data (cd/sq.m)

Luminance Data (cd/sq.m)

Luminance Data (cd/sq.m)

EFFICACY: 150 LM/W

EFFICACY: 125 LM/W

EFFICACY: 126 LM/W

0-180 : 1.2290-270 : 1.20Diagonal : 1.30

0-180 : 1.2290-270 : 1.20Diagonal : 1.30

0-180 : 1.2290-270 : 1.20Diagonal : 1.30

Spacing Criteria

Spacing Criteria

Spacing Criteria

24-OT-LED-5000L-DIM10-MVOLT-40K-85 TEST NO.: EL011995INPUT WATTS: 36.6 LUMENS: 5475 CRI: 85 EFFICACY: 150 CCT: 4000K

24-OT-LED-6000L-DIM10-MVOLT-40K-85 TEST NO.: EL011995INPUT WATTS: 46.6 LUMENS: 5812 CRI: 85 EFFICACY: 125 CCT: 4000K

24-OT-LED-7000L-DIM10-MVOLT-40K-85 TEST NO.: EL011993INPUT WATTS: 56.1 LUMENS: 7089 CRI: 85 EFFICACY: 126 CCT: 4000K

551

1101

1652

2203

585

1169

1754

2339

712

1424

2137

2849

90º

80º

70º

60º

50º

40º

30º 20º

10º

90º

80º

70º

60º

50º

40º

30º 20º

10º

90º

80º

70º

60º

50º

40º

30º 20º

10º

Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m

By Elite Lighting

24-OT-LED 2’x4’2 X 4 Foot LED Recessed Troffer Luminaire

Zonal Lumens Summary

Zonal Lumens Summary

Zone Lumens %Lamp %Fixt

Zone Lumens %Lamp %Fixt

0-300

0-400

0-600

0-900

0-1800

0-300

0-400

0-600

0-900

0-1800

2620.96 N.A. 30.604206.57 N.A. 49.106969.63 N.A. 81.308501.01 N.A. 99.208572.05 N.A. 100.00

2739.44 N.A. 30.604397.05 N.A. 49.107282.5 N.A. 81.308878.08 N.A. 99.208952.28 N.A. 100.00

Candle Power Distribution (Candelas)

Candle Power Distribution (Candelas)

RC - Ceiling Cavity Reflectance RW - Wall Reflectance

RC - Ceiling Cavity Reflectance RW - Wall Reflectance

ROOM

CAV

ITY

RATI

ORO

OM C

AVIT

Y RA

TIO

0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 991 109 104 100 96 106 102 98 95 98 95 92 94 91 89 90 88 86 842 100 92 85 80 97 90 84 79 86 81 77 83 78 75 80 76 73 713 91 81 73 67 89 79 72 66 76 70 65 73 68 64 71 66 63 604 84 72 64 57 81 71 63 57 68 61 56 66 60 55 64 59 54 525 77 65 56 50 75 64 56 49 61 54 49 59 53 48 58 52 48 466 72 59 50 44 70 58 49 43 56 48 43 54 48 43 52 47 42 407 66 53 45 39 65 52 44 39 51 44 38 49 43 38 48 42 38 368 62 49 41 35 60 48 40 35 47 40 34 45 39 34 44 38 34 329 58 45 37 31 57 44 37 31 43 36 31 42 36 31 41 35 31 2910 54 42 34 29 53 41 34 29 40 33 28 39 33 28 38 32 28 26

0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 991 109 104 100 96 106 102 98 95 98 95 92 94 91 89 90 88 86 842 100 92 85 80 97 90 84 79 86 81 77 83 78 75 80 76 73 713 91 81 73 67 89 79 72 66 76 70 65 74 68 64 71 66 63 604 84 72 64 57 81 71 63 57 68 61 56 66 60 55 64 59 54 525 77 65 56 50 75 64 56 49 62 54 49 59 53 48 58 52 48 466 72 59 50 44 70 58 49 44 56 49 43 54 48 43 52 47 42 407 67 53 45 39 65 53 44 39 51 44 38 49 43 38 48 42 38 368 62 49 41 35 60 48 40 35 47 40 34 45 39 34 44 38 34 329 58 45 37 31 57 44 37 31 43 36 31 42 36 31 41 35 31 2910 54 42 34 29 53 41 34 29 40 33 28 39 33 28 38 32 28 26

80%

80%

70% 50% 30% 10%

70% 50% 30% 10%

70% 50% 30% 10%

70% 50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

50% 30% 10%

0%

0%

70%

70%

50%

50%

30%

30%

10%

10%

0%

0%

RCRW

RCRW

Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 20% = PF

Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 20% = PF

05152535455565758590

05152535455565758590

3442.5243430.9803281.9612990.6662564.4052022.1121431.996

900.130460.835157.486

24.324

3597.5373586.2723427.5403121.9812668.9632103.1261493.441

923.069480.128158.357

16.924

3442.5243418.9363253.7272944.3412486.0251921.0251327.145

798.778414.756137.523

5.508

3597.5373573.7243401.6353074.7452592.9371994.7131367.945

822.856430.561144.070

5.325

3442.5243427.4913273.1222962.9712497.5301909.6081289.259

781.168437.374166.355

22.217

3597.5373580.8773420.5053096.3622608.3791993.2801345.686

814.863457.276172.979

22.487

0

0

45

45

90

90

Candela Tabulation

Candela Tabulation

Angle In Degrees

Angle In Degrees

450

550

650

750

850

450

550

650

750

850

Average 00

Average 00

3844 3652 36303356 3110 30212863 2541 24852393 2154 22722429 2121 2566

3998 3792 37893500 3206 31542936 2617 25922494 2236 23752442 2222 2668

Average 450

Average 450

Average 900

Average 900

Luminance Data (cd/sq.m)

Luminance Data (cd/sq.m)

EFFICACY: 127 LM/W

EFFICACY: 126 LM/W

0-180 : 1.2290-270 : 1.20Diagonal : 1.30

0-180 : 1.2290-270 : 1.20Diagonal : 1.30

Spacing Criteria

Spacing Criteria

24-OT-LED-8000L-DIM10-MVOLT-40K-85 TEST NO.: EL011994INPUT WATTS: 67.7 LUMENS: 8572 CRI: 85 EFFICACY: 127 CCT: 4000K

24-OT-LED-10000L-DIM10-MVOLT-40K-85 TEST NO.: EL011992INPUT WATTS: 71.2 LUMENS: 8952 CRI: 85 EFFICACY: 126 CCT: 4000K

863

1726

2589

3452

902

1805

2707

3609

90º

80º

70º

60º

50º

40º

30º 20º

10º

90º

80º

70º

60º

50º

40º

30º 20º

10º

Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m

By Elite Lighting

24-OT-LED 2’x4’

WATTST OPPEREasySense

1- Luminaire will be shipped with Powerpacks pre-installed, ready to be integrated to designated contol systems2- Luminaire will be shipped with Sensors installed on the luminaire, allowing for individual luminaire control. Luminaires will be ready to be integrated with designated control systems3- Luminaire will be shipped with Sensors to be remotely installed on the ceiling. Luminaires will be ready to be integrated with designated control systems

BRAND

CONTROL UNIT

o LEDRU LED Relay Zone Controller 0-10V 1

o FCJS-0-10 Lutron Vive 0-10V Individual Control Models 1 4

o CU-4E-FMH Fixture Mount Control Unit 1 5

o ZL027 –N0W Intellect Power Control Module 1 6

o EN-WCM2-ZB-DR Wireless Control Module 1 7 o XITANIUM

SR LED DRIVER The Philips Advance Xitanium SR LED driver 1 8

o LMFC-011 ON/OFF/0-10V dimming fixture controller 1 9

o LEDDU LED Zone Controller 0-10V 1

o FCJS-ECO Lutron Vive Eco-system Individual Control Models 1 4

o ZL027 –DLE Intellect Power Control Module 1 6

o EN- ALC-ZB-BK-DR Wireless Area Lighting Control Module 1 7

o FS-PP-V2 FS-PP Fixture Integrated Sensor Power Pack 1 9

INTEGRAT OCCOPANCY&

DAYLIGHT SENSOR

N/A

o DFCSJ-OEM-OCC Clear Connect (RF) and Occupancy/Daylight Sensing 2

o SU-5E-IoT IoT Node Micro Sensor o SU-5E-CL Connected Micro Sensoro SU-5E-IL Indipendent Micro Sensor o SU-5S-H(IoT/CL/IL) Serface Mount Sensor (Must be Specified with CU-4E-FMH Control Unit) 2

o ZL00J -T0W Intellect Intelligent Fixture Control System 2

o EN-CLM-PIR-DD-ZB SensiLUM™ Wireless Integrated Sensor

o SNS200 SNS200 for grouping 2

o FD-301 Fixture integrated Daylight Dimming Sensor 2

o ZL00J-D0W Intellect Intelligent Fixture Control System 2

o ZBHA-CLM-DIM-ENC Connected Lighting Module DIM 2

o SNS300 SNS300 for networks 2

o FS-205 Fixture integrated passive infrared occupancy sensor 2

*WIRELESS OCCUPANCY

SENSOR

o EOSCU-W-EO Occupancy Sensor - Ceiling Mounted 3

o LRF2-OCR2B-P-WH Ceiling mount360° ,occupancy/vacancy sensor 3

N/A N/A

o EN-SCPPH-1500-ZB Wireless Passive Infrared Occupancyand Photo Sensors 3

N/A

o LMDC-100 Dual technology PIR Ceiling Mount Occupancy Sensor 3

*WIRELESS DAYLIGHT SENSOR

o ELLSU-W-EO Light Level Sensor - Ceiling Mounted 3

o LRF2-DCRB-WH Ceiling-mount daylight sensor 3

N/A N/A

o EN-SCPPH-1500-ZB Wireless Passive Infrared Occupancyand Photo Sensors 3

N/A

o LMLS-400 Single zone switching and dimming digital photosensor 3

*WIRELESS OCCUPANCY & DAYLIGHT

SENSOR

N/A N/A

o SU-5E-IoT IoT Node Micro Sensor o SU-5E-CL Connected Micro Sensoro SU-5E-IL Indipendent Micro Sensor o SU-5S-H(IoT/CL/IL) Serface Mount Sensor

(Must be specified with CU-4E-FMH Control Unit) 3

o ZL00J -T0W Intellect Intelligent Fixture Control System

o ZL00J-D0W Intellect Intelligent Fixture Control System

(Must be specified with ZL027-NOW and ZL00J-D0W Control unit) 3

o EN-CLM-PIR-DD-ZB SensiLUM™ Wireless Integrated Sensor o ZBHA-CLM-DIM-ENC Connected Lighting Module DIM

(Must be specified with EN-WCM2-ZB-DR or EN- ALC-ZB-BK-DR Control Unit) 3

o SNS200-CMP SNS-200 for Grouping 3

N/A

ACCESORIES N/A N/A

o TMC-SU-5E Tile Mount Carrier o CBL-5E-CU4-30N 30 Iinch Sensor cable for CU-4 and IoT Readyo CBL-5E-CU4-7F 7 Foot sensor cable for CU-4 and IoT Ready Driver

N/A N/A N/A N/A

NOTES N/A

4- Luminaire will be compatible with LUTRON LRF2-0CR2B-PWH Ceiling mount 360deg occupancy/vacancy sensor & LRF2-DCRB-WH ceiling mount daylight sensor. Sensors must be orderd through Lutron

5- Luminaire will be compatible with ENLIGHTED SU-5E-IoT, SU-5E-CL, SU-5E-IL, SU-5SH, Sensors

6- Luminaire will be compatible with LEVITON I ntellect APP & Keypad room controller

7- Luminaire will be compatible with EN-SCPPH-1500-ZB Wireless passive infrared occupancy and photo sensor

8- Luminaire will be compatiable with philips field and wireless switch

9- Luminaire will be compatiable with DLM Room control system LMPB-100. . Sensors must be orderd through Legrand.

2 X 4 Foot LED Recessed Troffer Luminaire