2365/2366 advanced venipuncture training aid™...user manual 2365/2366 advanced venipuncture...
TRANSCRIPT
User Manual
2365/2366 Advanced Venipuncture Training Aid™
308 South Sequoia Parkway, Canby, Oregon 97013 USAph. 503.651.5050 | fax 503.651.5052 | email [email protected] | www.vatainc.com
www.vatainc.com
Thank you for your purchase of VATA’s - 2365/2366 Advanced Venipuncture Training Aid™
This model is now made with two of VATA’s newly developed materials, Dermalike II™ and Dermalike V™. The vein pad is made with Dermalike II™, and when used accord-ing to the instructions, offers many unique and improved properties.Some of the properties are:• Themodelisratedfor2400needleaccesses,thoughcustomershavereportedtheir
experienceis2-3timesthisnumber• 60% less needle drag when puncturing, which results in amuchmore realistic
experience• Improvedtearresistance,extendingtheusefullifeoftheproduct• Feelsandpalpateslikehumantissueforamorerealisticlearningexperience• Stainresistant
The veins are made of VATA’s latex free Dermalike V™. This material has properties moresimilartorealveinscomparedtothelatextubingpreviouslyusedonouroriginalAdvancedVenipuntureTrainingAidandstillbeingusedbyothermanufacturers.
The 2365 Advanced Venipuncture Training Aid™ features fourbarelydiscernableblueveinsof3differentdiameters–with the fourthveindeeplyplaced– inasemi-transparent,tissue-likepad.Whenaccessingarealistic“flashback”ofsimulatedbloodconfirmstheproperneedleplacement.Anoptionalcarryingcase,withstoragepouchforsupplies,isavailable(seepage10,0385).
PleasereadtheentireUser’sManualcarefullybeforeusingthemodeltoensurethatyou understand the proper care and use of this device. This will also avoid situations thatmaynotbecoveredbythewarranty,andhelpyoutoenjoythemaximumbenefits.
With exceptional “true to life” feel when accessing and the elimination of potentialreactions for those with latex sensitivity, this is a truly welcomed advancement in anatomical teaching models.
We understand that cost and useful life are important concerns when selecting teaching models.Wearepleasedtoofferarefurbishingservicetorestorethemodeltolike-newcondition(seepage8).
As always we welcome your suggestions and comments concerning ourproducts,asmanysignificant improvementsandnewproductideashavebeentheresultofourcustomers’suggestions.
To view our informational video on this product go to: www.vatainc.com/2365video
1
Thank You For Your Purchase!
www.vatainc.com
Product Components1 Base2 Vein pad of Dermalike II™3 Hinged cover plate for vein pad4 BubbleTrapWhiteCap5 BubbleTrap6 Blood Bag with
Simulated Blood7 Stopcock
1
3
6
4
5
2
7
2366DarklyPigmented
2
www.vatainc.com
Helpful Hints• Bychangingtheaccesslocationeachtimeandusingasharpnon-burred22gIVCatheter,youcanaccessthe2365model2400times,thoughcustomershavereportedtheirexperienceis2-3timesthisnumber.
• Do not place the Dermalike II™ vein pad in contact with productsmade ofvinylorPVCforprolongedperiodsoftime,asthechemicalsinthemwillcausedegradation of the vein pad.
• Storeflat toavoiddeformation.Checkthatstopcock,bubble trapandbubbletrapcaparesecurelyinplacebeforeclosingcover.Donotstorewithitemsontop of the vein pad as it will take on the impression permanently. Always store with the cover in place over the Dermalike II™ vein pad.
• Therearefourveinsofthreedifferentsizesinthemodel.Thefrontareaofthebasedisplaysfourredcirclesthatarethesamesizeastheinsidediametersoftheveinsforvisualizationofthespaceswhenaccessing.Thelargeveinontheleft is deeply placed. Though the veins may visually appear large, accessing andgettingaflashbackcanbemorechallenging.
• Allveinswillproducearealistic“flashback”whenaccessed.
• ThetissuepadofDermalikeII™isstainresistant.
• Thelifeoftheveinswillbemaximizedbytheuseof20gneedlesinthelargeandmediumveins.Thesmallveinshouldbeaccessedwitha24gorsmallerneedle.
• Avoid theuseofdull orburredneedlesas thesewill damage theveinsandcause premature leakage.
• Dependingonuse,overtime,itmaybecomenecessarytoreplacetheveinpadandveinsofthemodel.ThiscanbedonebycontactingVATACustomerServiceforourrefurbishingservice.
• Thesimulatedbloodprovidedisonlyforuseinmodelsandisnotintendedforanyotheruse.Wedonot recommendusingsimulatedblood item2491and2494withthismodel.
• Oursimulatedblood isstain resistant.Forbest results, rinse fabricwithcoldwaterassoonaspossibleaftercomingincontactwithsimulatedblood.
• Cleaningoftheveinpadisbestdonebywipingwithanalcoholwetted,non-lintingcloth.Thepadshouldbepermitted toairdryand thenpowderedwithcornstarchbabytalc.Anyexcesstalccanberemovedwithadrycloth.Ifatanytimetheveinpadbecomestackytothetouch,talcshouldbeapplied.
3
www.vatainc.com
1. Placefingerontabandpushintoopen hinged cover.
2. Opencovertoavertical position untilanaudible“click”isheard,confirmingthetop is in the locked position.
3. Removebubbletrapfromholder.
4. Unscrewcapandreplacebubbletrapinto holder.
Set-up Instructions
4
www.vatainc.com5
5. Turnhandleonstopcocktoaverticalposition;modelwillprimeinunder1minute.
6. Modelisprimedwhensimulatedbloodisvisibleinthebottomofthebubbletrap. If model does not prime see next step.
7. If model does not prime automatically, applylightpressuretosimulatedbloodbagtostartthepriming.
Set-up Instructions, Cont.
www.vatainc.com
1. Removestopcockfromthecover.
2. Removethesimulatedbloodbagfromthe hook on the cover.
3. Placesimulatedbloodbagbelowthelevel of the vein pad and simulatedbloodwilldrainfromthemodelinunder1minute.
4. Drainingiscompletewhennobloodisseenflowingthroughstopcock.
Storing Instructions
6
www.vatainc.com
5. Whenthemodeliscompletelydrained, turn the handle on thestopcocktoahorizontalposition.
6. Placethesimulatedbloodbagbackonto the hook in the cover.
7. Snapthestopcockbackintotheholder–anaudible“click”willconfirmproper placement.
8. Removebubbletrapfromcover.
Storing Instructions, Cont.
7
www.vatainc.com 8
9. Screwcapbackontothebubbletrap.
10.Snapbubbletrapintoholder–anaudible“snap”willconfirmproperplacement.
11.Stabilizebaseandapplyclosingpressure to cover to release from thelockedposition–anaudible“click”willconfirmdisengagement.
12.Anaudible“click”willbeheardwhen the cover isproperly closed.
Storing Instructions, Cont.
www.vatainc.com9
The model is supplied with a simulated bloodbagcontaining80cc.
Whensimulatedbloodneedstobeaddedtothebag,closethestopcockbyturningtoahorizontalposition.Removebagfromhook in cover. Position the needleless adapter in a superior position. Attach the prefilledsyringetotheneedlelessadapterandinfusethesimulatedblood.Repeatasneeded
Should you wish to remove air from the bag, close the stopcock by turning to ahorizontal position. Remove bag fromhook in cover. Position the needleless adapter in a superior position. Attach the syringe to the needleless adaptor and withdrawair.Repeatasneeded.
Care & Filling of Simulated Blood Bag
www.vatainc.com
Product # Description2365 Advanced Venipuncture Training Aid™
2366 Advanced Venipuncture Training Aid™Darkly Pigmented
0385 OptionalCarryingCaseforitems2365&2366
2367 SimulatedBloodReservoir–withStopcock
1491 SimulatedBlood,OneQuart–StainResistant
1494 SimulatedBlood,OneGallon–StainResistant
Thefollowingitemsareavailableforpurchasewithoutreturningyourmodel.Additionalreplacementpartsareavailableatwww.vatainc.com.
Refurbishing Service Thepurchaseof trainingmodels is a significant financial investment.Realizingthis, VATAisproudtoofferarefurbishingservicetobringyourmodeltolike-newcondition. Please call VATA Customer Service for instructions on how to return yourmodel.Once yourmodel is received, it will be evaluated and youwill becontactedtoapprovethecostofrefurbishingbeforeanyworkisperformed.Turn-aroundtimetocompletearefurbishingislessthanoneweek.
10
2365/2366 Models & Parts
200219
You might also like...
308 South Sequoia Parkway, Canby, Oregon 97013 USAph. 503.651.5050 | fax 503.651.5052 | email [email protected] | www.vatainc.com
1352-Two-VeinVenipunctureTrainingAid-DermalikeII™ 1353-Two-VeinVenipunctureTrainingAid,DarklyPigmented-DermalikeII™
1354-Four-VeinVenipunctureTrainingAid-DermalikeII™ 1355-Four-VeinVenipunctureTrainingAid,DarklyPigmented-DermalikeII™
2400-ChesterChest™WithNewAdvancedArm 2402-ChesterChest™WithNewAdvancedArm-DarklyPigmented
1352
1354
2400 2402
1355
1353