2344 a106-proposed first floor plan...proposed first floor plan 2344_a106 b 08/01/13hall width...

1
1. Do not scale drawings. All dimensions to be checked on site. Errors to be reported to architect. To be read in conjunction with all relevant architects services and engineers drawings. 2. Contractors, sub-contractors and suppliers to verify any critical dimensions on site prior to fabrication of any building element. Any discrepancies to be reported to the architect. 3. This drawing to be read in conjunction with all relevant specifications, engineers and specialists consultants information and any discrepancies reported prior to installation. Key Plan Notes Notes Revision Date Alison Brooks Architects Ltd Studio 610, Highgate Studios, 53/79 Highgate Road, London NW5 1TL T 0207 267 9777 F 0207 267 9772 E [email protected] Client : Scale : Date : Drawing : Title : Project : EXETER COLLEGE A3 - 1:200 : A1 - 1:100 18.07.13 EXETER COLLEGE WALTON STREET QUAD PROPOSED FIRST FLOOR PLAN 2344_A106 B 08/01/13 Hall width increased, Updated to Stage D Information 0 2 1 5 0 2 1 5 Amended to draft planning submission. C 15/02/13 Detailed Planning Submission D 18/03/13 Detailed Planning Submission. E 25/03/13 Detailed Planning Submission Amendments F 19/07/13 R22 R10 R11 R12 R13 R14 R15 R16 R17 R18 R19 R20 R21 R23 R24 R25 R26 R30 R31 R33 R2 R2 R5 R6 R3 R8 R1 R37 CP CP CP F F RAD Stair 2 Stair 1 Stair 3 L2 L1 Student Rm 1.01 Student Rm 1.02 Student Rm 1.03 Student Rm 1.04 Student Rm 1.05 HK Store 1.06 Student Rm 1.07 Student Rm 1.08 Student Rm 1.09 Student Rm 1.10 Student Rm 1.11 Family Kitchen 1.12 36.5 sqm Student Rm 1.13 Student Rm 1.14 Student Rm 1.15 Student Rm 1.16 Student Rm 1.17 Student Rm 1.18 Student Rm 1.19 Student Rm 1.20 HK Store 1.21 Student Rm 1.22 Student Rm 1.23 Student Rm 1.24 Student Rm 1.25 Student Rm 1.26 Student Rm 1.27 Student Rm 1.28 Student Rm 1.29 Student Rm 1.30 HK Store 1.31 10.7sqm Student Rm 1.32 Student Rm 1.33 Student Rm 1.34 Student Rm 1.35 Student Rm 1.36 Student Rm 1.37 Student Rm 1.38 Student Rm 1.39 Student Rm 1.40 Student Rm 1.41 Ensuite 1.41B Ensuite 1.01B Ensuite 1.02B Ensuite 1.03B Ensuite 1.04B Ensuite 1.05B Ensuite 1.07B Ensuite 1.08B Ensuite 1.09B Ensuite 1.10B Ensuite 1.11B Ensuite 1.13B Ensuite 1.14B Ensuite 1.15B Ensuite 1.16B Ensuite 1.17B Ensuite 1.18B Ensuite 1.19B Ensuite 1.20B Ensuite 1.22B Ensuite 1.23B Ensuite 1.24B Ensuite 1.25B Ensuite 1.26B Ensuite 1.27B Ensuite 1.28B Ensuite 1.29B Ensuite 1.30B Ensuite 1.32B Ensuite 1.33B Ensuite 1.34B Ensuite 1.35B Ensuite 1.36B Ensuite 1.37B Ensuite 1.38B Ensuite 1.39B Ensuite 1.40B Hall Roof Roof Light to Hall Metal Roof to Cycle Store +TOW 62.000 +TOW 62.000 +TOW 61.537 +TOW 62.590 +TOW 62.952 +65.225 +65.225 +65.225 +65.225 Smoke Vent Smoke Vent South Quad Cloister Below RWP Existing RWP Existing RWP Existing RWP Existing RWP RWP RWP RWP

Upload: others

Post on 11-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2344 A106-Proposed First Floor Plan...PROPOSED FIRST FLOOR PLAN 2344_A106 B 08/01/13Hall width increased, Updated to Stage D Information 0 1 2 5 C 15/02/13Amended to draft planning

1. Do not scale drawings. All dimensions to be checked on site. Errors to be reported to architect. To be read in conjunction with all relevant architects services and engineers drawings.

2. Contractors, sub-contractors and suppliers to verify any critical dimensions on site prior to fabrication of any building element. Any discrepancies to be reported to the architect.

3. This drawing to be read in conjunction with all relevant specifications, engineers and specialists consultants information and any discrepancies reported prior to installation.

Key PlanNotesNotesRevision Date

Alison Brooks Architects LtdStudio 610, Highgate Studios, 53/79 Highgate Road, London NW5 1TLT 0207 267 9777 F 0207 267 9772 E [email protected]

Client :

Scale :

Date :

Drawing :

Title :

Project :

EXETER COLLEGEA3 - 1:200 : A1 - 1:100

18.07.13

EXETER COLLEGE WALTON STREET QUADPROPOSED FIRST FLOOR PLAN

2344_A106

B 08/01/13 Hall width increased, Updated to Stage D Information

0 21 50 21 5

Amended to draft planning submission.C 15/02/13

Detailed Planning SubmissionD 18/03/13

Detailed Planning Submission.E 25/03/13

Detailed Planning Submission AmendmentsF 19/07/13

R22

R10

R11

R12

R13

R14

R15

R16

R17

R18

R19

R20

R21

R23

R24 R25 R26

R30 R31 R33

R2R2R5

R6

R3

R8

R1

R37

CP

CPCP

FF

RAD

Stair 2

Stair 1

Stair 3

L2

L1

Student Rm1.01

Student Rm1.02

Student Rm1.03

Student Rm1.04

Student Rm1.05

HK Store1.06Student Rm

1.07Student Rm

1.08Student Rm

1.09Student Rm

1.10Student Rm

1.11Family Kitchen

1.1236.5 sqm

Student Rm1.13Student Rm

1.14Student Rm1.15Student Rm

1.16Student Rm1.17

Student Rm1.18

Student Rm1.19Student Rm

1.20HK Store1.21

Student Rm1.22

Student Rm1.23

Student Rm1.24

Student Rm1.25

Student Rm1.26

Student Rm1.27

Student Rm1.28

Student Rm1.29

Student Rm1.30

HK Store1.31

10.7sqm

Student Rm1.32

Student Rm1.33

Student Rm1.34

Student Rm1.35

Student Rm1.36

Student Rm1.37

Student Rm1.38

Student Rm1.39

Student Rm1.40

Student Rm1.41

Ensuite1.41B

Ensuite1.01B

Ensuite1.02B

Ensuite1.03B

Ensuite1.04B

Ensuite1.05B

Ensuite1.07B

Ensuite1.08B

Ensuite1.09B

Ensuite1.10B

Ensuite1.11B

Ensuite1.13BEnsuite

1.14BEnsuite1.15B

Ensuite1.16BEnsuite

1.17BEnsuite1.18BEnsuite

1.19BEnsuite1.20B

Ensuite1.22B

Ensuite1.23B

Ensuite1.24B

Ensuite1.25B

Ensuite1.26B

Ensuite1.27B

Ensuite1.28B

Ensuite1.29B

Ensuite1.30B

Ensuite1.32B

Ensuite1.33B

Ensuite1.34B

Ensuite1.35B

Ensuite1.36B

Ensuite1.37B

Ensuite1.38B

Ensuite1.39B

Ensuite1.40B

Hall Roof

Roof Light to HallMetal Roof to Cycle Store

+TOW 62.000 +TOW 62.000

+TOW 61.537

+TOW 62.590

+TOW 62.952

+65.225

+65.225

+65.225

+65.225

Smoke Vent

Smoke Vent

South Quad Cloister Below

RWP

ExistingRWP

ExistingRWP

ExistingRWP

ExistingRWP

RWP

RWP

RWP

sonya.beecher
Amended Plan