220 minicomfort - led - comlux led 2015/220-225 minicomfort.pdf · direct glare generated by a...
TRANSCRIPT
220220 Minicomfort - LED
FLICKER
FREE
Housing: in galvanised steel sheet panels, pre-coated with a polyester resin.
Equipment: hinged door and quick clamping mechanism. With protective film on fixture and baffle louvre. Supplied without bra-ckets: for non-surface mounted ver-sions, use bracket acc. 326.
Dimmable 0041: standard DALI
On request: DIMM 1/10V version.
UGR<19 glare index: compliant with applicable standards (reflec-tion coefficient: ceiling 0.7 - walls 0.5).
Easy connectionEquipped with hinged door and quick clamping mechanism.
Protective filmSupplied with a protective film to prevent the fixtures from accumula-ting dirt and to keep the optics clear and ensure perfect performance.
The economic benefits of the new technologies alone are not able to ensure efficiency without the combina-tion of other important advantages. The most significant one concerns the quality of light. New lighting fixtures will make you live and work better. The picture shows how lighting quality is the result of a set of elements con-nected to visual perception. These elements include visual performance, associated with the level of lighting, glare limitation, visual comfort, which is determined by the correct distribution of light and by a good colour rendering and ambient lighting, which depends on the colour of the light source and on light beam direction. In other words, a good lighting system is one that ensures the right amount of light, without producing glare and where colours can be admired almost as if they were viewed under natural light.
CCCooolllooouuurrr rrrrrreeeeeennndddeeerrriiinnnggg
CCCooorrrrrreeeccctttllliiiggghhhttt
LLLiiiggghhhtttiiiiiinnnnnnggggggllleeevvveeellliiiGGGlllaaarrreeellliiimmmmmmiiiiiittttttaaa
tttiiiooo
nnn
LLLiiiggghhh
tttcccooo
lllooouuurrr
LLLiiiggghhh
tttbbbeeeeee
aaaaaammm
LLLiiiggghhhttt
ddddddiiiiiissssssttttttrrrrrriiiiii bbbbbbuuuuuuttttttiiiiiioooooonnnnnn
ddddddiiiiiirrreee
ccctttiiiooo
nnn
pppooosssiiitttiiiiiioooooonnnnnniiiiiinnnnnngggggg
Excellent Excellent Excellent lighting lighting lighting
Classification of UGR values by applications
UGR≤ 16 Very demanding applications (technical drawings≤ 19 Offi ces and schools (reading, writing, business meetings, computer work)≤ 22 Industrial applications, craftsmen> 28 High glare
The UGR (unifi ed glare rating) is an international unifi ed measure developed by the CIE (Commission International de l’Eclairage) to assess the direct glare generated by a lighting system. The European standard regulating the lighting of indoor work places (UNI-EN 12464-1) recom-mends a specifi c UGR value for different applications ranging between 10 and 30; the lower the UGR value, the lower the glare. The exact value of this index differs by project type because it depends on the position of the luminaires, room characteristics (dimensions, refl ections) and on the point of observation of viewers.
Flicker-Free: uniform light with no flicker for greater eye protection.
LED: Power factor: 0,95Power consumption: 18/28/37WLuminous flux maintenance 80% 50000h (L80B20)Colour temperature: 4000 K (On request: 3000K )
06A LED Interni_minicomfort.indd 220 04/07/15 11.45
221Minicomfort - LED 221
energy saving!!!
Level 1
Level 3
Level 2
Level 1
Level 2
Level 3
Level 1
Level 2Level 3
INT
ER
IOR
S
On request “Smart sensor”: Smart sensor is an energy effi ciency controller for LED panels and dim-mer fi ttings. It uses 1-10V DC dimming technology to control all connected lighting fi xtures. Smart sensor also features occupancy sensing and daylight harvesting components and programming units to ensure energy effi ciency and lower power consumption.
At the heart of the system is the sensor node, which is integrated into each luminaire during assem-bly. Each sensor node contains a motion sensor, infrared transmitter, infrared receiver, ambient light sen-sor and intelligent microprocessor.
Smart sensor integrated. Remote control to purchase separately.
How it works. 01When a sensor node detects occu-pancy of a space, it turns on its luminaire to a predetermined light level (e.g. 100%). It simultaneously communicates this occupancy to its neighbouring luminaires using a level 1 proximity-limited infrared signal.
02 On receipt of the level 1 signal, the neighbouring sensor node switches its own luminaire to a predetermined light level, which is appropriate to the occupant standing in that space (e.g. 80% brightness), and simultaneously relays a level 2 signal to its own neighbours.
03This communication propaga-tes rapidly throughout the fl oor with each sensor node receiving a signal indicating how close a occupant is to it, adjusting its light level accordingly (level 3)
Presence detectorLights turn on when they detect movement and turn off when they are no longer needed. This offers further savings. Order with subcode -0092.
Motion detectors have a wide DETECTION range and react to people’s MOVEMENT.The sensor IMMEDIATELY SWITCHES ON the connected device whe-never it senses movement within its scan area, automatically distingui-shing between NIGHT and DAY. It can see motion through doors, win-dows and thin walls.
For more energy savings
1-10V DIMMER: 1-10V dimming allows a minimum dim level of 10% and the connection to a pre-sence and light sensor.
DALI DIMMER: thanks to pre-programmed settings or a sof-tware programme, this type of wiring allows accurate light emission dimming.
PRESENCE AND LIGHT SENSORAn automatic, easy-to-use, safe and prac-tical sensor. A completely new energy-saving device, equipped with a high level of sensitivity.
06A LED Interni_minicomfort.indd 221 04/07/15 11.46
222 Minicomfort - LED
841
new
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm
841
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm
new
energy saving!!!
UGR<19
UGR<19
586x586
293x1185
596
60
596
60
294
1196
60
1196
29463
596
63
596 596
586x1185
596
60
596 - 1196
63
596
FLICKERFREE
FLICKERFREE
IP20IK07ENEC
IP20IK07ENEC
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
841 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 2x white 2.50 1196 153533-00 153533-0041 33 4000K - 5200lm - CRI≥80
841 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 2x white 2,50 596 153536-00 153536-0041 16 4000K - 2600lm - CRI≥80
841 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 2+2 white 5.00 1196 153537-00 153537-0041 33 4000K - 5200lm - CRI≥80
06A LED Interni_minicomfort.indd 222 08/07/15 17.55
223
105
h=10
16
Minicomfort - LED
new
841
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm
new
841
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm
energy saving!!!
UGR<19
UGR<19
596
60
596
60
294
1196
60
1196
29463
596
63
596 596
586x586
586x586
596
60
596
60
294
1196
60
1196
29463
596
63
596 596
FLICKERFREE
FLICKERFREE
IP20IK07ENEC
IP20IK07ENEC
INT
ER
IOR
S
acc. 326 adjustable bracketgalvanized 998059-00
In zinc plated steel. 4-pc set to be used when art. 841 is not contact mounted.
acc. 320 safety cord998004-00
Steel safety cord.
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
841 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 4x white 3.50 596 153535-00 153535-0041 33 4000K - 5200lm - CRI≥80
841 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 3x white 3.30 596 153534-00 153534-0041 25 4000K - 3900lm - CRI≥80
06A LED Interni_minicomfort.indd 223 08/07/15 17.56
224
596
1196
63
294
63
UGR<19
UGR<19
731
new
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm
596
60
596 - 1196
63
63
63
596
596
60
596 - 1196
63
63
63
596
731
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm
new
energy saving!!!
FLICKERFREE
FLICKERFREE
IP20IK07ENEC
IP20IK07ENEC
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
731 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 2x white 2.50 1196 143533-00 143533-0041 33 4000K - 5200lm - CRI≥80
Minicomfort ceiling fixture - LED
731 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 2x white 3.50 596 143536-00 143536-0041 16 4000K - 2600lm - CRI≥80
06A LED Interni_minicomfort.indd 224 08/07/15 17.56
225
new
731
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm596
1196
63
294
63
ø108
81
45
45
190
UGR<19
596
60
596 - 1196
63
63
63
596
596
60
596 - 1196
63
63
63
596
new
731
5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚
45˚45˚
55˚55˚
65˚65˚
75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚
150
300
450
600
750cd/Klm
energy saving!!!UGR<19
FLICKERFREE
FLICKERFREE
IP20IK07ENEC
IP20IK07ENEC
INT
ER
IOR
S
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
Dark light louvre: double para-bolic louvres, in high-gloss 99.99 aluminium, anti-glare and anti-iri-descence, very low luminance with PVD treatment or in double para-bolic louvres, in high-gloss 99.85 aluminium.
acc. 2519 powered suspensionm. silver 993909-00
Suspension supplied with steel wire, 1.75 m long with millimetric adjustment and power cable. Max load 20 kg. 5 poles.
acc. 2608 electrified suspen-sion
white 994617-00
Nylon cover and steel brackets. With steel wire Ø1,5mm; L=1,5m - 30Kg, and millimetric adjustment.
731 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 2x white 2.50 1196 143533-00 143533-0041 33 4000K - 5200lm - CRI≥80
731 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 4x white 3.50 596 143535-00 143535-0041 33 4000K - 5200lm - CRI≥80
Minicomfort ceiling fixture - LED
731 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 2x white 3.50 596 143536-00 143536-0041 16 4000K - 2600lm - CRI≥80
731 MinicomfortCLD CELL CLD CELLD-D LED (Tj=25°C)
wattage/W colour weight L code code W K - ølm - CRI
LED 3x white 3.50 596 143534-00 143534-0041 25 4000K - 3900lm - CRI≥80
06A LED Interni_minicomfort.indd 225 08/07/15 17.56