21128 robin shortform catalogue 2014 v7
TRANSCRIPT
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
1/28
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
2/28
Electrical Test Equipment from Beha-Amprobe
Beha-Amprobe two of the most famous brands
in the US and Germany have now incorporated
Robin Installation testers within the range
available to customers in the UK and Ireland.
Beha-Amprobe offers wide range of cost-
effective, innovative test equipment specically
designed to make the electrician’s job faster
and easier. This includes the Robin range of
single, dual and multifunction 17th Edition
Installation Testers specically designed for
testing xed installations in the UK and Ireland.
Beha-Amprobe products are sold and supported
by a wide range of dealers and are backed up
by a professional support service. The vast
array of Beha-Amprobe products, plus the
incorporation of the Robin electrical range,means the UK electrician has a one stop shop for
quality, value-priced products which include 17th
Edition Installation Testers, Voltage Detectors,
Multimeters, Clamp Meters, Thermometers
and Two Pole Testers - one of the largest ranges
available to the electrical contractor and engineer.
Single & Dual FunctionInstallation Testers . . . . . . . . . . . . . . . 3
Portable Appliance Testers . . . . . . . . 7
Electrical Testers . . . . . . . . . . . . . . . . 9
Clamp-on Meters . . . . . . . . . . . . . . . 12
Digital Multimeters . . . . . . . . . . . . . . 15
Temperature Measurement . . . . . . . 18
Other Test Equipment . . . . . . . . . . . 21
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
3/28
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
4/28
n Three levels of trip currents (x1/2, x1, x5) for complete
range of testing applications
- Fast Trip Function (KMP7020)
- Ramp Test (KMP7021)
n 3-LED proper connection indicator
n Phase switch selection 0° and 180° for
positive and negative semi-cycle testing
n Designed to allow testing to BS7671
IEE 17th Edition regulations
n Large display
n Safety CAT III 300V
n Non Trip Loop test
n Fast testing
n Instant reading
n 20, 200 & 2000Ω Loop measurement ranges
n PSC measurement up to 20kA
n Displays mains voltage before test
n Instant correct wiring status check
n Designed to allow testing to BS7671
IEE 17th Edition regulations
n
Backlight displayn Low Battery Indication
n CAT III 300V
KMP7020/KMP7021Digital RCD Tester
KMP7030Loop Impedance Tester
Robin-Amprobe RCD testers are simple to use devices
designed to check for correct operation of RCD devices.
They feature three levels of trip currents with either Fast Trip
or Ramp Test for complete range of testing applications.
A residual-current device (RCD) disconnects a circuit whenever
the electric current is not balanced between the energised
and the neutral conductors. The imbalance indicates that
there is a leakage current outside of the system sometimes
caused by the person accidentally touching the energised part
of the circuit, and sometimes by lack of sufficient insulation
(excessive moisture or worn out, poor quality insulationmaterials). RCDs are designed to disconnect quickly to mitigate
the harm caused by such shocks and to avoid current leaks
which may lead to fire and other dangerous situations.
Loop testing is a quick, convenient, and highly specific method
of evaluating an electrical circuit for its ability to engage
protective devices (circuit breakers, fuses, RCD’s). A “loop” is
defined by including unsuspected elements, where current has
found parallel paths to ground. A ground loop determines the
effectiveness of protective devices, therefore it is crucial to be
able to measure it, in order to detect and correct problems.
KMP7020
KMP7021
4
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
5/28
S i n g l e - F
u n c t i o n
I n s t a l
l a t i o n T
e s t e r s
KMP7010Ground Resistance Tester
Robin-Amprobe Ground Resistance Testers are designed
to measure resistance of the grounding systems to verify
that the system has low enough resistance to provide
protection for people, equipment and structures.
A properly functioning grounding system is a critical safety
feature of an electrical system. It is used to mitigate the risk
when exposed metal parts come in contact with dangerous
voltages in the event an installation fails. The building
structures are protected by grounding systems to divert
energy of lightning strikes straight to ground. Connections to
ground limit the build-up of static electricity when handling
flammable products or when repairing electronic devices.
n Measures Earth ground resistance -
3 point (fall of potential) or 2 point testsn Voltage measurement prevents false measurementsn Test leads, auxiliary electrodes are
included for a complete instrumentn Built-in memory to store 20 measurementsn Designed to allow testing to BS7671 IEE 17th
Edition regulationsn Safety CAT III 600V
KMP7036Insulation-Continuity Tester
n
Tests insulation of wires, cables,transformers and electrical motors
n Selectable test voltages 250V, 500V and 1000Vn Test button hold to perform the
Dielectric Absorption Ratio Testn Continuity test @ 200mA short-circuitn Designed to allow testing to BS7671
IEE 17th Edition regulationsn Built in voltmeter and red light warning
for live circuit indicationn Automatic discharge of test object after
completion of measurementn Test lead resistance zero facilityn Safety CAT III 600V
The Robin-Amprobe Insulation-Continuity Tester is designed
to diagnose and prevent the breakdown of the insulation in
various parts of the electrical system such as wires, transformers
and motors. The KMP7036 features three testing voltages
covering wide range of commercial and residential applications.
The quality of insulation is critical to assure proper,
uninterrupted and safe functioning of electrical circuits.
17A
Kits - Single Function Installation Testers
KMP7036 Insulation Tester
KMP7036 Insulation TesterCarry case includedwith both kits
KMP7030 Earth Loop Impedance Tester
KMP7030 Earth Loop Impedance Tester
KMP7020 RCD Tester
KMP7021 RCD Tester
+ +
17B
+ + 5
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
6/28
KMP7100Dual Function Loop /
RCD Tester
Robin-Amprobe KMP7100 is a dual function installation
tester combining both Earth Loop Impedance tester and
RCD tester in one compact easy to use package. Ideal for
use with the Robin Amprobe 7036 Insulation tester.
n Loop Functions
- Non Trip Loop test
- Fast testing - 20, 200 & 2000Ω Loop measurement ranges
- PSC measurement up to 20kA
- Displays mains voltage before test
- Instant correct wiring status check
n RCD Functions
- Three levels of trip currents (X1/2, X1, X5)for complete range of testing applications
- Phase switch selection 0° and 180° for
positive and negative semi-cycle testing
- Test pulse sensitive (DC) RCDs
- Auto RCD test
- Selectable 25V/50V fault voltage for RCD test
n Designed to allow testing to BS7671
IEE 17th Edition regulations
n Displays mains voltage before test
n “Test lock” for automatic start testwhen connected to circuit
n Dual measurement result display - primary display for
RCD/Loop measurement, secondary
display for circuit voltage
n Built-in Volt meter
n Safety CAT III 300V
KTS1625Digital Multifunction Tester
(Insulation / Continuity / Loop / RCD / Voltage
Safety and performance are two most critical requirements
for every electrical system. The quality of insulation, properly
working grounding system and active protection are to
assure safety of people, electrical systems and buildings
against electrocution, fire, and other equipment damage.
Robin-Amprobe KTS1625 tester verifies the safety of electrical
installations in domestic, commercial and industrial applications. It
can ensure that fixed wiring is safe and correctly installed to meetthe requirements of BS7671 IEE 17th edition wiring regulations.
n Continuity Functions
- Continuity resistance @ 200mA
n Insulation Function
- Selectable test voltages 250V, 500V & 1000V
n Line / Loop Impedance Functions
- Prospective earth fault current
- Prospective short-circuit current
- Non Trip Loop test
- Fast testing
n RCD Functions
- Three levels of trip currents (X½, X1, X5)
for complete range of testing applications
- Phase switch selection 0° and 180° for
positive and negative semi-cycle testing
- RCD ramp test
- Tests time delayed RCDs (S-type)
- Test pulse sensitive (DC) RCDs
- Auto RCD test
n Designed to allow testing to BS7671
IEE 17th Edition regulations
n
Voltage and frequency measurementsn Instant correct wiring status check
n Dual measurement result display
n Large, backlit display
n Low battery indication
n Safety CAT III 300V
Accessories for Robin-Amprobe testersERT2 Earth resistance kit
SL17B Standard test lead set e/leads, probes,
alligator clips and mains lead
TP1625 Test probe with remote test button for KTS1625
SL7030 Standard test lead set for KMP7030
KP1700 Single function tester kit carry bag
SL17E Fused test lead set w/probes, al ligator clips
6
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
7/28
Portable Appliance Testers
Robin-Amprobe Portable Appliance Test –
Built Tough to Test the Safety and Integrity
of Electrical Appliances
7
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
8/28
GT-400-UKPortable Appliance Tester
The new Robin-Amprobe GT-400-UK Portable
Appliance Tester, is a light- weight, portable appliance
tester that tests the integrity of electr ical devices.
Developed for the commercial electrician or facilities
maintenance persons to carry out a wide variety of
safety measurements of electrical appliances, the
GT-400-UK is extremely easy to use. Measuringearth ground and insulation resistance, as well as
current, the GT-400-UK will ensure safety,
functionality and compliance of regulatory standards.
n Intuitive and simple to use with no training required
n Easily portable for on the go testing
n Fast answers - Instantly measures safety and
integrity of electrical appliances
n Measures earth bond resistance
n Insulation resistance measurements up to 500V
n Substitute Leakage Current measurements
n Protective Conductor Current measurements
n Rugged with high quality construction for years of service
n Tests appliances for safety in accordance
with the IET Code of Practice, EN 61010 Safety Standards
8
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
9/28
The range of Beha-Amprobe Electrical Testers
include Non-contact & Two Pole Testers.
Electrical Testers
9
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
10/28
VP-720-EVoltage Tester LCD with Phase Rotation
Additional Features
n Vibration function
n Test of 30mA RCD by both push buttons,
avoids unintended tripping of RCD
n Torch function via white LED
n Quick single-hand test on 19 mm
contact distance sockets
n Built and certified according to latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011
n Voltage test via LCD-Display and
LED-Bargraph (12-690V AC/DC)
n Single pole test for phase polarity
n Continuity test
n Two pole phase indication,
no third hand required
n Switchable Load of 140 W
with two push buttons,
tripping of 30 mA RCD
n Automatic AC/DC voltage
indication, indication of polarity
n IP 64, splash-proof anddust-tight protection
n Probe tip protection for reducing
the danger of injuries (attached
to lead - permanently available)0
VP-700-EVoltage Tester with
Rotary Field Indicator
nVoltage test (12-690V AC/DC)
nTwo pole phase rotation
indication, no third hand required
nIndication of polarity
nSwitchable Load of 140 W
with two push buttons,
tripping of 30 mA RCD
nIP 64, splash-proof anddust-tight protection
nProbe tip protection for reducing
the danger of injuries (attached
to lead - permanently available)
Additional Features
nNo unawared tripping of RCD
nNo battery required
nQuick single-hand on 19 mm contact distance outlets,
without removing test probe from instrumentnBuilt and certified according latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011
VP-710-EVoltage Tester with
Phase Rotation
Additional Features
n Quick single-hand on 19 mm contact distance outlets,
without removing test probe from instrument
n Torch function via white LED
n Built and certified according latest voltage testerstandard EN-61243-3:2010, DIN VDE 0682-401:2011
nVoltage test (12-690V AC/DC)
nTwo pole phase rotation indication,
no third hand required
nSingle pole test for phase polarity
nContinuity test
nSwitchable Load of 140 W with two
push buttons, tripping of 30 mA RCD
nAutomation AC/DC voltage
indication, indication of polarity
nIP 64, splash-proof and
dust-tight protection
nProbe tip protection for reducing
the danger of injuries (attached
to lead - permanently available)
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
11/28
V o
l t a g e T
e s t e r s
11
VP-440 RTNon-contact Voltage
Tester
n Non-contact, optical
detection of AC voltages
n 50-1000V AC
n Fast, accurate detection of
cable breaks in open-ended
cables, e.g. cable drums
n Compact, handy design
that fits in any pocket
n Wide range of applications
in trade and industry
2050-DVOLTfix plus – non-contactvoltage tester
VP-450-ENon-contact VoltageTester
Non-contact, optical and acoustic
detection of AC voltages. Fast, exact
location of line breaks in cables lying
open e.g. cable drums. Reliable, automatic
self-test at start-up of the equipment
by visual standby display. Compact,
handy design, which fits in any pocket.
n CAT III 600 V
n Optical and acoustic detection
n Integrated flashlight
n Compact, handy design
n Optical standby display.
n Non-contact, optical and acoustic
detection of AC voltages
n 50-600V AC
n Fast, accurate detection of
cable breaks in openended
cables, e.g. cable drums
n Reliable, automatic self-
test of activated device with
optical readiness indicator
n Compact, handy design
that fits in any pocket
n Wide range of applications
in trade and industry
Additional Features
n On/off switch
nFast and accurate locating of
fuses and assignment to circuits
nLocating and tracing
of cables in walls
nSet consisting of transmitter and
receiver in robust carrying case
nTransmitter signal displayed
optically and acoustically
by the receiver
nTransmitter with integrated
BS1363 UK plug enabling easy
connection to mains socket
nSimple switching between fuse
and cable finder function
nContinuous sensitivity
adjustment of receiver
ECB50A-ECircuit Breaker Finder
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
12/28
Beha-Amprobe are renowned around
the world for innovative Clamp Meters.
The selection includes the Swivel Clamp
Meter and the high performance
Navigator Clamp.
Clamp-on Meters
2
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
13/28
ACDC-400Clamp Multimeter 400A
ACD-20SWSwivel Clamp Meter 400A
n Current, voltage and
resistance measurementn Continuity test with beeper
n Measurement of inrush
current (30 ms)
n Automatic and manual
range selection
n Integrated measurement
memory (data hold)
n Jaw opening: 50 mm
n Auto power-off
Additional Features
n Large, clear display
ACDC-100Clamp Multimeter 1000A
n Current, voltage and
resistance measurement
n Continuity test with beeper
n Automatic and manual
range selection
n Integrated measurement
memory (data hold, MIN/MAX)
n Relative measurement
n Additional bar graph display
n Jaw opening: 30 mm
n Auto power-off
Additional Features
n AC/DC clamps are also suitable
for automotive applications,
emergency power supplies
and solar technology
n Backlight
ACD-14 PLUSCurrent clamp with dual
display up to 600 A (AC)
nCurrent, voltage and
resistance measurement
nContinuity test with beeper
nCapacitance and frequency
measurement
nTemperature measurement
nMeasurement of inrush current
nAutomatic range selection
nIntegrated measurement memory
(data hold and MAX hold)
n Jaw opening: 26 mm
nAuto power-off
Additional Features
nDual display
nA measurement range for direct
measurement of ionisation
currents in heating systems
nMeasures current, voltage
and resistance
nAudible continuity test
nDiode test
nAuto and manual ranging
nMeasured data storage
(Data Hold)
nAccomodates conductors
up to 30 mm in diameter
nAuto-Power-Off
Additional Features
n180 degree rotating head
for the perfect display
nAdvanced VoltTect non-
contact voltage detection
C l a m p - o
n M
e t e r s
13
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
14/28
4
LH41Current Clamp Meter AC/DC
n Current measurement
from 1 mA AC and DC
n Manual range selection
n Jaw opening: 19 mm
n Automatic zero-point (DC
measurement range)
n Integrated 5 s measurement
memory (data hold)
n Auto power-off
Additional Features
n Minimum resolution: 1 mA
n Shielded against external
interference
n Leakage current measurement
n Voltage and resistance
measurement
n Continuity test with beeper
n Manual range selection
n Integrated measurement
memory (data hold)
n MIN/MAX and relative
value measurement
n Additional bar graph display
n Jaw opening: 30 mm
n Auto power-off
Additional Features
n Minimum resolution: 0.01 mA
n Range of applications:
measurement of leakageor fault currents, current
consumption of devices in
(customer) service sector
without breaking the circuit
AC50ALeakage Clamp Meter
ACD-50NAV600A AC Navigator Clamp
n Current, voltage andresistance measurement
n Measurement of activepower (W)
n Measurement of thepower factor cos ф
n Acoustic continuity testn Capacity and frequency
measurementn Harmonics measurement for
current and voltage values(up to the 25th harmonic)
nTHD measurement
nMeasurement of theinrush currentnDisplay of the rotary
field directionnAutomatic measuring
range selectionnTRMS measurement (ACD-
52NAV, ACD-53NAV,ACD-54NAV only)
n Integrated measurement
memory (Data Hold,MIN/MAX)n Additional bargraph displayn Peak value measurementn Low Pass frequency filtern Large clear display with
background lightn Clamp opening 37 mmn Auto-Power-Off
Additional FeaturesnReal effective value measurement AC+DC (TRMS)nContactless voltage detectionnMeasurement point illumination by means of white LED
ACDC-54NAV1000A AC/DC TRMSNavigator Clamp
n Current, voltage andresistance measurement
n Acoustic continuity testn Capacity and frequency measurementn Temperature measurementn Measurement of effective power (W)n
Measurement of thepower factor cos фn Harmonic measurement for
current and voltage values(up to the 25th harmonic)
n Measurement of the inrush currentn Display of the rotary field directionn Automatic measuring range selectionn Integrated measurement memory
(Data Hold, MIN/MAX)n Additional bargraph displayn Peak value measurementn Low Pass frequency filtern Large clear display with
background lightn Clamp opening 42 mm
n Auto-Power-Off
Additional FeaturesnReal effective value measurement AC+DC (TRMS)nContactless voltage detectionnMeasurement point illumination by means of white LED
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
15/28
15
Beha-Amprobe offer a wide range of Digital
Multimeters for the UK electrician at
affordable prices.
Digital Multimeters
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
16/28
6
AM-520-EURDMM
n750V AC/DC
n 10A AC/DC
n Capacitance and frequency
measurement
n Temperature measurementn Automatic and manual
range selection
n Auto power off
n Non-contact voltage detection
n Built-in flashlight
Contents
n Model AM-520 EUR
n Test leads
n 1 x Temperature probe
n Carrying case
n 1 x 9V (6F22) battery (installed)
n Users manual
n Hang strap
AM-530-EURDMM TRMS
nAC 750V/DC 1000V
n10A AC/DC
nTRMS measurement
nCapacitance and frequency
measurement
nTemperature measurement
nAutomatic and manual
range selection
nAuto power off
nNon-contact voltage detection
nBuilt-in flashlight
Contents
nModel AM-530 EUR
nTest leads
n1 x Temperature probe
nCarrying case
n1 x 9V (6F22) battery (installed)
nUsers manual
nHang strap
AM-500-EURCompact Size DMM
nAutoranging feature
automatically sets up
voltage, current, and
resistance ranges for you
nVoltage up to 600V AC/DC
nResistance
nAudible continuity
nDiode test
nData hold
nAuto power off
nLow battery warning
nSafety rated: CAT III 600V
Contents
n Model AM-500 EUR
n Test leads
n AAA x 2
n Users manual
AM-510-EURDMM
n 600V AC/DC
n10A AC/DC
n Capacitance and frequency
measurement
n Temperature measurement
n Automatic and manual
range selection
n Auto power off
n Battery test (1,5V and 9V)
n Non-contact voltage detection
n Built-in flashlight
Contents
n Model AM-510 EUR
n Test leads
n 1 x 9V (6F22) battery (installed)
n Users manual
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
17/28
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
18/28
The Beha-Amprobe series of infrared and
contact thermometers are a complete
line of high performance diagnostic tools
designed for HVAC/R, electrical, industrial
maintenance applications.
Temperature Measurement
18
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
19/28
T e m p e r a t u r e
M e a s u r e m e n t
19
IR-710-EURInfrared Thermometer (10:1)
nExtremely accurate and reliable
nPrecise measurement with
distance to spot ratio 10:1
nWide temperatures
ranges available up to
-0°F to 716°F
(-18°C to 380°C )
nRapid response time
nLaser pointer for accurate targeting
n8 seconds auto display
hold for easy read-out
nAdjustable emissivity for
measuring a variety of materials
nDual LCD display with backlight
nSelectable ˚F and ˚C
IR-720-EURInfrared Thermometer (20:1)
nExtremely accurate and reliable
nPrecise measurement with
distance to spotratio 20:1
nWide temperatures
ranges available up to
-26°F to 1922°F
(-32°C to 1050°C )
nRapid response time
nLaser pointer for accurate targeting
n8 seconds auto display
hold for easy read-out
nAdjustable emissivity for
measuring a variety of materials
nDual LCD display with backlight
nSelectable ˚F and ˚C
IR-750-EURInfrared Thermometer (50:1)
nExtremely accurate and reliable
nPrecise measurement with
distance to spot ratio 50:1
nWide temperatures
ranges available up to
-58°F to 2822°F
(-50°C to 1550°C )
nRapid response time
nLaser pointer for accurate targeting
n8 seconds auto display
hold for easy read-out
nAdjustable emissivity for
measuring a variety of materials
nDual LCD display with backlight
nSelectable ˚F and ˚C
nStores up to 99 data points
nThermocouple inputnUSB interface
IR-730-EURInfrared Thermometer (30:1)
nExtremely accurate and reliable
nPrecise measurement with
distance to spot ratio 30:1
nWide temperatures
ranges available up to
-26°F to 2282°F
(-32°C to 1250°C )
nRapid response time
nLaser pointer for accurate targeting
n8 seconds auto display
hold for easy read-out
nAdjustable emissivity for
measuring a variety of materials
nDual LCD display with backlight
nSelectable ˚F and ˚C
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
20/28
20
TMD-50Thermometer
TMD-50, Type K
n Dual (Temperature
measurement with connection
for two sensors)n -60 to 1350 °C, -58 to 2498 °F
n Measurement of the
temperature difference
n Connection for two
temperature sensors type K
n Switchable for measurement
in °C or °F
n Integrated measurement
memory (Data Hold)
n MIN/MAX and relative
value measurement
n Measurement of the
average temperature
nBacklit display
n Auto-Power-Off
Additional Features
n Best precision 0.1%
n T1-T2 (temperature
difference)
n Shock and impact-
resistant by standard
protective cover
IR608AInfrared Thermometer
Laser Pointer
n Non-contact temperature
measurement
n Switchable between °C
and °F measurement
n Integrated measurement
memory (data hold)
n Backlight
n Distance to spot size ratio: 8:1
n Auto power-off
Additional Features
n Laser-based targeting
n Handy and compact
“pistol grip” design
IR-450-EURPocket Infrared Thermometer
nIR pocket thermometer with
8:1 distance to spot ratio
nSelectable °F / °C
nHolds temperature
reading for 10 seconds
nBright laser pointer
nBuilt-in LED flashlight to
illuminate dark areas
TH-3Relative Humidity
Temperature Meter
n Dual display
nRelative function monitors
humidity and temperature
changes
nExtended probe stem to easily
access air ducts
nMin/Max readings
Data Hold
nCapacitive sensor with
protective cover
nAuto Power off
nSoft Carrying Case
nOne-year warranty
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
21/28
Need something a little different? Always
check the Beha-Amprobe range. This section
has a selection of other Beha-Amprobe
test equipment for electrical and HVAC
applications.
Other Test Equipment
21
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
22/28
22
TMA10Anemometer ThermometerAnemometer with remote vane
n Measure CFM by inputting
the vent dimensions
n Obtain air flow average by
taking up to eight data points
n Vane has three foot cord for
measurement flexibilityn Deluxe carrying case
n Measure air velocity or air flow
n RS232 interface output
with optional software
and cable, TM-SWA
n Continuous moving average
for up to 2 hours
LM-100Light Meter Manual Ranging
n Light measurement
n 0-200,000 lux
n Manual range selection
n Silicon sensor
n Integrated measurement
memory (data hold, MAX)
LAN-1Lan Cable Tester
nTest pin configuration for:
10/100 base -T cable
10 base-2 cable
RJ45 modular cables
AT&T 258A cable
EIA/TIA 568A/568B cables
Token Ring Cable
nVerify the cable wiring for
continuity, opens, shorts or
incorrect wiring
nTest installed cable on wallplate or the patch panels by
using the Remote
Termination module
nPerform Loopback Test
or Remote Test
nBuzzer sound warning for
error condition in cable
nTwo sets of LED lights for
Source and Test indication
LM-120Light Meter withAuto Ranging
nMeasure in Lux or Footcandles,
front panel switchable
nMeasuring Range to 200,000
Lux or 20,000 Foot candlesnSilicon photodiode
sensor and filter
nData Hold to freeze reading
on the digital display
nMIN / MAX ability to show
high and low readings
nAutoranging plus Manual Range
nZero function to null
display before a reading
nAuto Power Off to
PRM4
Phase Sequence and MotorRotation Tester
n Identifies 3-phase sequence
and open phase check
n Motor shaft rotation indication
protected by CAT III circuitry
n CAT III 600V rated for
both testing segments
n Meets current EN61010 safety
requirements, CSA, EN61557-7
n Supplied with three CAT IIIrated color coded large
alligator clips and test leads
n Zippered carrying case
for portability
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
23/28
O
t h e r s
23
SM-10Sound Meter
nMeasurement of sound leveln30-130 dB
nMeasurement according to
frequency evaluation filters A
and C, with direct display in dB
nIntegrated measurement
memory (data hold, MAX)
nSwitchable between fast
and slow response times
nBacklight
TACH20Combo Tachometer
nMeasures rotational
and surface speed
nBuilt-in memory
nDigital Display
nAuto power off function
nEasy to select units
and mode functions
nContact and non-
contact measurement
nSelect rpm using infrared
beam or adapter: m/min, m/sec, ft/min, ft/sec, in/min, m, ft, and in.
nIncludes 6 Adapters, Carrying
Case, Reflective Tapes,
Batteries and User Manual
PQ55ACompact Power Analyser
n Comprehensive real time
monitoring, recording and
analysis of three phase
power systems
n True-rms voltage and
current measurementn Power Factor and
phase angle results
n Power Analysis (apparent,
active and reactive power)
TX900Microwave Leakage
Detector
n Measures for wave leakage
and tests oven power
n 8 dipole sensors – allows
detection of plane wave signals
of any polarization
n Temperature compensation
– accurate reading regardless
of ambient temperature changesn Compact, ergonomic design
n Low battery indication
n Analog Bar Graph
n Auto-zero
LT-10-EURLamp Tester
nDetermine if fluorescent light
bulbs are operational prior
to installation or removal
nVerify voltage presence without
the need for another tool with
built-in VolTect™ non-contact
voltage detection
nIncrease productivity
by minimising trips up
and down a ladder
nAll tests performed with easy,
single button operation
nUltra-compact design
for portability
nIndustry leading 120cm
(48”) removable, fully
retractable antenna
nInsulated antenna sleeve
for safe testing
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
24/28
24
Specifications (At 23°C ± 5°C, 45% to 75% RH)
Insulation Resistance @250V/500/1000V (TestCurrent ≥ 1mA)
0.00MΩ ~ 250MΩ@ 250V0.00MΩ ~ 500MΩ@ 500V0.00MΩ~1000MΩ@ 1000V
(Buzzer threshold: 2MΩ)
±(5% rdg + 5 LSD)
Continuity @ IN ≥ 200mA,Uo=5Vdc (Nominal)
0.00Ω ~ 199Ω(Buzzer threshold: 20Ω)
±(2% rdg + 5 LSD)
AC Voltage Measurement 0Vac ~ 400Vac ±(5% rdg + 2 LSD)@ 45 to 65Hz
Operating Voltage(Loop and RCD)
230Vac, 45Hz ~ 65 Hz +10% to -15%
Line Impedance (L – N) @ 25A 0.01Ω ~ 1.99Ω / 2.0Ω ~19.9Ω / 20Ω ~ 2000Ω
±(5% rdg + 5 LSD)
Loop Impedance
(L – PE) @ 25A
0.01Ω ~ 1.99Ω / 2.0Ω ~
19.9Ω / 20Ω ~ 2000Ω
±(5% rdg + 5 LSD)
Loop impedance withouttripping @ 15mA
0.01Ω ~ 1.99Ω / 2.0Ω ~19.9Ω / 20Ω ~ 2000Ω
± (5% rdg + 12 LSD+ Noise Margin
(0.01 - 1.99Ω))
Prospective Short CircuitCurrent (PSC) @ 25A
Prospective Earth Fault
Current (PSC) @ 25A
0.00A ~ 1.99A / 2.0A~ 19.9A / 20A ~ 199A
/ 200A ~ 1.99kA
/ 2.0kA ~ 26kA
PSC accuracy derivedfrom measured loop
impedance specification
and measuredvoltage specification
RCD Test Current 10/30/100/300/500mA 0% to 10% @1∆n and 5∆n≤-10% to 0% @ ½∆n
RCD Trip Times @ X½ 0 ~ 2000ms(10/30/100/300/500mA)
±(1% rdg + 2 ms)
RCD Trip Times @ X1 0 ~ 500ms (selective)(10 / 30 / 100 /300 / 500mA)
±(1% rdg + 2 ms)
RCD Trip Times @ X1 0 ~ 300ms (10 / 30/ 100 / 300mA)
±(1% rdg + 2 ms)
RCD Trip Times @ X5 0 ~ 40ms (10 /
30 / 100mA)±(1% rdg + 2 ms)
RCD Auto Test X½ / X1 / X5 (10
/ 30 / 100mA)Trip time: ±(1% rdg +
2 ms) Trip current: 0%to 10% @ 1∆n and 5∆n-10% to 0% @ ½∆n
RCD RAMP Test X½ / X1 / X5 (10 / 30/ 100 / 300 / 500mA)
50% ~ 110% Defaultnominal residual
currents (I∆n).Increasing by10%, total 7
steps of residual current
Fault Voltage Detection(N – PE conductor)
50Vac or more
Operating Temperature 0°C to +40°C, ≤ 85% RH, no condensation
Storage Temperature -20°C to +60°C, ≤ 90% RH, nocondensation (without batteries)
Power Supply 1.5V Alkaline Battery (AA Battery) × 8 pcs
Dimensions (L x W x H) 189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)
Product Weight Approx. 1.3 kg (2.87 lb) with batteries installed
Regulat ion Compliance Designed to a llow test ing to BS7671IEE 17th Edition regulations
BS EN 61010-1 CAT III 300VBS EN 61557-1 / -2 / -3 / -4 / -6 / -10
BS EN 61326-1 (EMC)
Included Accessories 3-Wires mains test cord set , test lead (red,black green), test probe (red, black, green),alligator clips (red, black, green), Test probewith Remote Test Button, users manual,strap and carrying case
KTS1625
Specifications (At 23°C ± 5°C, 45% to 75% RH)
Operating Voltage 230Vac, 45Hz ~ 65 Hz +10% to -15%
Earth Loop Impedance 20Ω 0.01Ω ~ 19.99Ω@ Nominal Test
Current 25A
±(3% rdg + 4 LSD)
Earth Loop Impedance 200Ω 20.0Ω ~ 199.9Ω@ Nominal Test
Current 2.3A
±(3% rdg + 4 LSD)
Earth Loop Impedance 2000Ω 200Ω ~ 1999Ω@ Nominal Test
Current 15mA
±(3% rdg + 4 LSD)
Non tripping Loop test 20Ω 0.01Ω ~ 19.99Ω ±(3% rdg + 6 LSD)
Non tripping Loop test 200Ω 20.0Ω ~ 199.9Ω ±(3% rdg + 7 LSD)
Prospective Short Circuit
Current (PSC)200A / 2000A / 20kA
0.0 ~ 199.9 /
1999 / 19.9kA
PSC accuracy derived
from measured loop
impedance specificationand measured
voltage specificationRCD Test Current 10/30/100/300/500mA 0% to 10% @
1∆n and 5∆n≤-10% to 0% @ ½∆n
RCD Trip Times @ X½ 0 ~ 2000ms(10/30/100/300/500mA)
±(1% rdg + 2 ms)
RCD Trip Times @ X1 0 ~ 1000ms (selective)(10/30/100/300/500mA)
±(1% rdg + 2 ms)
RCD Trip Times @ X1 0 ~ 1000ms
(10/30/100/300mA)±(1% rdg + 2 ms)
RCD Trip Times @ X5 0 ~ 40ms
(10/30/100mA)±(1% rdg + 2 ms)
RCD Auto Test X½ / X1 / X5 (10/ 30 / 100mA)
Trip time: ±(1%rdg + 2 ms)Trip current: 0% to10% @ 1∆n and 5∆n
-10% to 0% @ ½∆nRCD RAMP Test X½ / X1 / X5 (10 / 30
/ 100 / 300 / 500mA)50% ~ 110% Defaultnominal residual
currents (I∆n).Increasing by 10%,total 7 steps of
residual current
Fault Voltage Detection(N – PE conductor)
Selectable 25V or 50Vac
Voltage Measurement 0Vac ~ 600Vac ± (2% rdg + 3 LSD)@ 45Hz ~ 65 Hz
Operating Temperature 0°C to +40°C, ≤ 85% RH, no condensation
Storage Temperature -20°C to +60°C, ≤ 90% RH, nocondensation (without batteries)
Power Supply 1.5V Alkaline Battery (AA Battery) × 8 pcs
Dimensions (L x W x H) 189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)
Product Weight Approx. 450g (0.99 lb)
Regulation Compliance Designed to a llow test ing to BS7671IEE 17th Edition regulations
BS EN 61010-1 CAT III 300V
BS EN 61557-1 / -3 / -6 / -10BS EN 61326-1 (EMC)
Included Accessories 3-wires mains test cord with UK plug , test leads(red, black green), test probes (red, black,green), alligator clips (red, black, green),users manual, strap and carrying case
KMP7100
Multi-Function Installation Testers
Technical Specification
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
25/28
T e c
h n
i c a l
S p e c i f
i c a t
i o n
25
Specifications (At 23°C ± 5°C, 45% to 75% RH)
Earth Resistance Measurement 0.00Ω ~ 40.00Ω0.0Ω ~ 400.0Ω0Ω ~ 4000Ω
± (2% rdg + 20 LSD)± (2% rdg + 3 LSD)± (2% rdg + 3 LSD)
Voltage Measurement 0Vac ~ 400Vac ± (1% rdg + 6 LSD)@ 50 / 60 Hz
Operating Temperature +5°C to +40°C, ≤80% RH, no condensation
Storage Temperature -20°C to +60°C, ≤90% RH, nocondensation (without batteries)
Power Supply 1.5V Alkaline Battery (AA Battery) × 6 pcs
Dimensions (L x W x H) 160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)
Product Weight Approx. 500g (1.1 lb) with batteries installed
Regulation Compl iance Designed to al low testing to BS7671
IEE 17th Edition regulationsBS EN 61010-1 CAT III 400V
BS EN 61557-1, BS EN 61557-5
BS EN 61326-1 (EMC)
Included Accessories Three Test Leads (Green, Yellow and Red),Auxiliary ground rods, Two test leads withalligator clips, Batteries ( 6 x AA), UsersManual, Strap and Carrying case
Specifications (At 23°C ± 5°C, 45% to 75% RH)
Insulation Resistance @
250V/500/1000V (TestCurrent ≥1mA)
0.00MΩ ~ 4.99MΩ5.0MΩ ~ 49.9MΩ50MΩ ~ 999MΩ1.00GΩ ~ 1.99GΩ(Buzzer threshold: 4MΩ)
± (3% rdg + 5 LSD) for0.00MΩ ~ 99.9MΩ± (5% rdg + 5 LSD) for 100MΩ ~ 1.99GΩ
Continuity @ IN ≥200mA,Uo=5Vdc (Nominal)
0.00MΩ ~ 9.99 MΩ10.0MΩ ~ 99.9 MΩ
± (2% rdg + 5 LSD)
AC Voltage Measurement 30Vac ~ 750Vac ± (2% rdg + 3 LSD)@ 50 / 60Hz
Operating Temperature 0°C to +35°C, ≤75% RH, no condensation
Storage Temperature -20°C to +60°C, ≤80% RH, nocondensation (without batteries)
Power Supply 1.5V Alkaline Battery (AA Battery) × 6 pcs
Dimensions (L x W x H) 160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)
Product Weight Approx. 450g (0.99 lb) with batteries installed
Regulat ion Compliance Designed to a llow test ing to BS7671IEE 17th Edition regulations
BS EN 61010-1 CAT III 600V
BS EN 61557-1 / -2 / -4 / -10BS EN 61326-1 (EMC)
Included Accessories Test Leads (red, black), probes (red, black),alligator clips (red, black), Battery, InstructionManual, Carrying case, Strap
KMP7010 KMP7036
Specifications (At 23°C ± 5°C, 45% to 75% RH)
Operating Voltage 230Vac, 45Hz ~ 65 Hz +10% to -15%
Loop Impedance 20
/ 200 / 2000Ω0 ~ 19.99 / 199.9
/ 1999 Ω±(3% rdg + 4 LSD)
AC Test Current 25A Nominal at 20Ω
AC Test Period 10ms at 20Ω
No Trip Loop Impedance20 / 200Ω
0 ~ 19.99 / 199.9 Ω (L – N impedance > 20 Ω)
± (3% rdg + 6 LSD)
PSC Measurement 200A/ 2000A / 20kA
0.0 ~ 199.9 /1999 / 19.9kA
PSC accuracy derivedfrom measured loop
impedance specification
and measuredvoltage specification
Voltage Measurement 100Vac ~ 300Vac ± (2% rdg + 4 LSD)@ 50/60Hz
Operating Temperature 0°C to +40°C, ≤ 85% RH, no condensation
Storage Temperature -20°C to +60°C, ≤ 90% RH, nocondensation (without batteries)
Power Supply 1.5V Alkaline Battery (AA Battery) × 8 pcs
Dimensions (L x W x H) 189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)
Product Weight Approx. 450g (0.99 lb)
Regulat ion Compliance Designed to a llow test ing to BS7671
IEE 17th Edition regulationsBS EN 61010-1 CAT III 300V
BS EN 61557-1, BS EN 61557-3BS EN 61326-1 (EMC)
Included Accessories Mains Test cord with Earth Probe,
Batteries (8 x AA), User’s Manual,Strap and Carrying Case
Specifications (At 23°C ± 5°C, 45% to 75% RH)
Operating Voltage 230Vac, 50 Hz +10% to -15%
Trip current @ X½ 10/20/30/100/300/500mA
(trip time 0 to 2000ms)Trip current tolerance:
-10% to +10%Trip Time: ± (2%
rdg + 2 LSD)
Trip current @ X1 10/20/30/100/300mA(trip time 0 to 1000ms)500mA (trip time0 to 300ms)
Trip current tolerance:0% to +10%
Trip Time: ± (2%rdg + 2 LSD)
Trip current @ X5 10/20/30mA (trip
time 0 to 40ms)Trip current tolerance:
0% to +10%Trip Time: ± (2%
rdg + 2 LSD)
Fast Trip Current (KMP7020) 250mA (trip time0 to 40ms)
Trip current tolerance:0% to +10%
Trip Time: ± (2%
rdg + 2 LSD)Ramp Test (KMP7021) 10/20/30/100/300/500mA -10% to +10%
Ramp increase by 10%Default nominal residual currents
from 20% to 110%
Maximum measuring time 300ms x 10 times
Operating Temperature 0°C to +40°C, ≤80% RH, no condensation
Storage Temperature -20°C to +60°C, ≤90% RH, no condensation
Power Supply AC mains 230V +10% -15%, 50 Hz
Dimensions (L x W x H) 160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)
Product Weight Approx. 450g (0.99 lb)
Regulation Compl iance Designed to al low testing to BS7671
IEE 17th Edition regulations
BS EN 61010-1 CAT III 300VBS EN 61557-1, BS EN 61557-6
BS EN 61326-1 (EMC)
Inc luded Accessories 3-Wires Mains Test Cord, Test Lead Set,Users Manual, Strap and Carrying case
KMP7020/KMP7021 KMP7030
Single-Function Installation Testers
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
26/28
Technical Specification
26
Clamp-on Meters
Clamp Multimeter Comparison GuideACD-14 Plus ACDC-400 ACD-20SW ACDC-100 ACD-50NAV
Display
LCD, 33/4-digit,
4000 digits
LCD, 3¾ Digit,
3999 Count
LCD, 3¾ Digit,
3999 Count
LCD, 3¾ Digit,
4000 Count
LCD, 3¾ Digit,
4000 Count
M e a s u r e m e n t
R a n g e s
Current AC 0.01 - 600 A 0.01 A - 400 A 0.01 - 400 A 0.1 A - 800 A 0.01 - 600 A
Tolerance ±(1.9% rdg. + 8 digits) ±(1.5% rdg. +3 Digits) ±(2% rdg +6 Digits) ±(1.5% rdg. +5 Digits) ±(1.5 % rdg. +5 Digits)
Frequency Range 50/60 Hz 50/60 Hz 50-60 Hz 50 Hz - 400 Hz
Current DC - 0.01 A - 400 A - 0.1 A - 1000 A -
Tolerance - ±(1.5% rdg. +3 Digits) - ±(1.5% rdg. +4 Digits) -
Voltage AC 0.001 - 600 V 0.1 mV - 600 V 1.0 mV-600,0 V 0.1 mV - 600 V 0.01 - 1000 V
Tolerance ±(1.5% rdg. + 5 digits) ±(1% rdg. +3 Digits) ± (1.2% rdg +5 Digits) ±(1% rdg. +4 Digits) ±(1 % rdg. +5 Digits)
Frequency Range 50 - 400 Hz 50 - 500 Hz 50 - 500 Hz 50 - 500 Hz 50 Hz - 500 Hz
Voltage DC 0.1 - 600 V 0.1 mV - 600 V 0.1 mV - 600 V 0.1 mV - 600 V 0.01 - 1000 V
Tolerance ±(0.5% rdg. + 3 digits) ±(0.8% rdg. +2 Digits) ±(0.5% rdg +2 Digits) ±(0.5% rdg. +3 Digits) ±(0.7 % rdg. +2 Digits)
Continuity R < 120 Ω R < 40 Ω R < 25 Ω R < 120 Ω R < 30 Ω
Frequency 0.001 Hz - 100 kHz - - - 20,00 - 9,999 kHz
Resistance 0.1 - 40.00 MΩ 0.1 Ω - 40 MΩ 0.1 Ω - 40 MΩ 0.1 Ω - 40.00 MΩ 0.1–99.99 kΩ
Tolerance ±(0.8% rdg. + 6 digits) ±(1% rdg. +3 Digits) ±(1.0% rdg +4 Digits) ±(0.8% rdg. +6 Digits) -
Capacity 0.1 nF - 3000 µF - - - -
Active Power - - - - 0 - 600.0 kW
Cos Phi - - - - -1.00–0.00 – +1.00
Harmonics - - - - display up to the 25th
F e a t u r e s
Jaw Opening Ø 26 mm Ø 30 mm Ø 30 mm Ø 50 mm Ø 37 mm
Pollution Degree 2 2 2 2 2
Overvoltage Category CAT III/600 V CAT III/600 V CAT lll/600 V CAT III/600 VCAT IV 600V,CAT III 1000V
Safety EN 61010/IEC 61010DIN VDE 0411,
EN 61010, IEC 61010DIN VDE 0411,
EN 61010/IEC 61010DIN VDE 0411,
EN 61010, IEC 61010DIN VDE 0411,
EN 61010, IEC 61010
Power Supply2 x 3 V battery,IEC CR2032
2 x Battery 1.5 V,IEC LR03
2 x Batterie 1.5 V,IEC LR03
2 x Battery 1.5 V,IEC LR03
1 x Battery 9 V,IEC 6F22
Dimensions 190 x 63 x 32 mm 205 x 64 x 39 mm 240 × 70 × 41 mm 227 x 78 x 40 mm 260 x 80 x 40 mm
Weight approx. 200 g approx. 280 g approx. 220 g approx. 290 g approx. 480 g
Clamp Multimeter Comparison GuideACDC-54NAV LH41 AC50A
DisplayLCD, 3¾ Digit,
4000 Count
LCD, 3¾ Digit,
4000 Count
LCD, 3¾ Digit ,
3999 Count
M e a s u r e m e n t
R a n g e s
Current AC 0.01-1000 A 0.001 - 40 A 0.01 mA - 60 A
Tolerance ±(1.5 % rdg. +5 Digits) ±(1.3 % rdg. +5 Digits) ±(1.5% rdg. +5 Digits)
Frequency Range 50 Hz - 400 Hz 40 - 400 Hz 40 Hz - 1 kHz
Current DC - 0,001 - 40 A -
Tolerance - ±(1.3 % rdg. +5 Digits) -
Voltage AC 0,01 - 1000 V - 0,1 - 400 V
Tolerance ±(1 % rdg. +5 Digits) - ±(2% rdg. + 4 Digits)
Frequency Range 50 - 500 Hz - 40 Hz - 1 kHz
Voltage DC 0.01 - 1000 V - -
Tolerance ±(0.7% rdg. +2 Digits) - -
Continuity R < 30 Ω - R < 40 Ω
Frequency 20.00 - 9.999 kHz - -
Resistance 0.1–99.99 kΩ - 0.1 - 400 Ω
Tolerance ±(1% rdg. +5 Digits) - ±(1% rdg. +2 Digits)
Capacity - - -
Active Power 0 - 999.9 kW - -
Cos Phi -1.00–0.00 – +1.00 - -
Harmonics display up to the 25th - -
Temperature -50 °C-1000 °C - -
Input Impedance - - 10 MΩ
F e a t u r e s
Jaw Opening Ø 37 mm Ø 19 mm Ø 30 mm
Pollution Degree 2 2 2
Overvoltage Category
CAT IV 600V,
CAT III 1000V CAT III/600 V CAT III/600 V
SafetyDIN VDE 0411,
EN 61010/IEC 61010
DIN VDE 0411,
EN 61010, IEC 61010
DIN VDE 0411
EN 61010, IEC 61010
Power Supply1 x battery 9 V,
IEC 6F22
1 x Battery 9 V, IEC 6LR61
2 x Battery 1.5 V,IEC LR6
Dimensions 260 x 80 x 40 mm 184 x 71 x 31 mm 210 x 62 x 36 mm
Weight approx. 480 g approx. 235 g approx. 200g
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
27/28
T e c
h n
i c a l
S p e c i f
i c a t
i o n
27
Portable Appliance Testers
Specifications GT-400-UK Protective conductor resistance 0.10 ... 2.00 Ω ± (5% + 10 digits) Insulation resistance 0.100 ... 9.999 MΩ, 10.00 ... 20.00 MΩ ± (5% + 2 Digits) Substitute leakage current 0.100 ... 9.999 mA, 10.00 ... 20.00 mA ± (5% + 2 Digits)
Supplied with Test leads, alligator clip, test probe, IEC lead, carrying
case, 6 AA batteries, users manual
Protective Conductor Resistance Measuring range 0.10 ... 2.00 Ω Display range 0.05 ... 2.00 Ω Resolution 0.01 Ω Tolerance ± (5% + 10 digits) Measuring current / voltage Min. ± 200 mA DC / > 4 V
Insulation Resistance Measuring range 0.1 ... 20 MΩ Display range 0.1 ... 20 MΩ Resolution 0.1 ... 9.999 MΩ 0.001 MΩ / 10.00 ... 20.00 MΩ 0.01 MΩ Tolerance ± (5% + 2 digits) Measuring current / voltage Min . 500 V DC / >1 mA
Substitute Leakage Current Measuring range 0.1 ... 20 mA Display range 0.1 ... 20 mA Resolution 0.1 ... 9.999 mA 0.001 mA / 10.0 ... 20.00 mA 0.01 mA Tolerance ± (5% + 2 digits) Measuring current / voltage Approximately 32 V AC
General Specifications
Power supply 6 x 1.5 V Batteries (IEC LR6 (AA) 6 x 1.2 V NiMH rechargeable batteries
Degree of pollution 2 Overvoltage category CAT II 300 V
Protection degree IP40 Protection class II Electrical safety EN61010-1/VDE0411 EMC emission EN61000-6-3 EMC interference resistance EN61326-1 Dimensions (L x W x H) Approximately 265 x 110 x 50 mm Weight Approximately 700 g
GT-400-UK
Digital Multimeters
Series Selection Guide AM-500-EUR AM-510-EUR AM-520-EUR AM-530-EUR AM-540-EUR AM-550-EUR
MULTIMETER TYPE Autoranging Com / Res HVAC Electrical Adv. HVAC Industrial
F u n c t i o n s
Safety Rating Safety CAT III 600V CAT III 600V CAT III 600VCAT II 1000 CAT III 600VCAT II 1000 CAT IV 600CAT III 1000 CAT IV 600CAT III 1000
Measure voltage in noisy environments True-rms n n
Electrical panels, AC outlets AC Voltage (V) 600 600 750 750 1000 1000
DC systems, auto/marine batteries DC Voltage (V) 600 600 1000 1000 1000 1000
AC Current - electrical panels, appliances AC Current (A) 10 10 10 10 10 10
DC Current - electronics, DC motors DC Current (A) 10 10 10 10 10 10
Specified resistance and continuity Resistance (MOhms) 20 40 40 40 60 60
Flame sensors Microamps n n n n n n
Diodes in AC to DC converters Diode Test n n n n n n
Fuses, li ghtbulbs, wire connect ions Continui ty n n n n n n
Household batteries Battery test n n
Motor startup or run capacitors Capacitance n n n n n
Frequency verification Frequency n n n n n
Non-contact voltage test Non-contact voltage n n n n n
Electrical load-time on vs time off Duty cyc le n n n
Temp of air vents, fuses, transformers Temperature inputs 1 1 2 2
F e a t u r e s
Automatically selects measurement range Autoranging n n n n n n
Manually select measurement range Manual ranging n n n n n
Voltage on variable frequency drives Low pass fi lter n n
Detect stray voltages Low Z n
Dimly lit areas Built-in flashlight n n n n n
D i s p
l a y
Meter resolution LCD Counts 2,000 4,000 4,000 4,000 6,000 6,000
Dimly lit areas Backlight n n n n n
Monitoring fast changing signals Bar graph n n n n
Two relative measurements on one screen Dual display n n
E v e n t s
Data memory Data hold n n n n n n
Difference between two measurements Relative reading n n n n n
Max/min peak measurement Max/min hold n n n n
Specialised signal measurements Peak hold (crest) n n
Subject to change
-
8/19/2019 21128 Robin Shortform Catalogue 2014 v7
28/28
Robin-Amprobe ® Test Tools UK
52 Hurricane Way, Norwich, Norfolk, NR6 6JB, United KingdomWeb: www.robin-amprobe.co.uk / www.beha-amprobe.com