2018 annual drinking water quality report

6
2018 Annual Drinking Water Quality Report VALLEY MUNICIPAL UTILTY DISTRICT NO. 2 100 Hidalgo Avenue, Rancho Viejo, Texas (956) 350-4136 Special Notice for the ELDERLY, INFANTS, CANCER PATIENTS, people with HIV/AIDS or other immune problems: Some people may be more vulnerable to contaminants in drinking water than the general population. Immuno- compromised persons such as persons with cancer undergoing chemotherapy, persons who have undergone organ trans- plants, people with HIV/AIDS or other immune system disorders, some elderly, and infants can be particularly at risk from infections. These people should seek ad- vice about drinking water from their health care providers. The EPA/Centers for Disease Control and Prevention (CDC) guidelines on appropriate means to lessen the risk of infection by Cryptospor- idium and other microbial contaminants are available from the Safe Drinking Wa- ter Hotline (1-800-426-4791). Public Participation Opportunities Date: July 16, 2019 Time: 9:00 AM Location: 100 Hidalgo Phone No: (956) 350-4136 Valley MUD #2 has regular board meetings on the third Tuesday of every month. These meet- ings are open to the public. To request an agen- da , please call us. Our Drinking Water Meets or Exceeds All Federal (EPA) Drinking Water Requirements This report is a summary of the quality of the water we provide our customers. The analysis was made by using the data from the most recent U.S. Environmental Protection Agency (EPA) required tests and is presented in the attached pages. We hope this information helps you become more knowledgeable about what's in your drink- ing water. SOURCES OF DRINKING WATER: The sources of drinking wa- ter (both tap water and bottled water) include rivers, lakes, streams, ponds, reservoirs, springs, and wells. As water travels over the sur- face of the land or through the ground, it dissolves naturally- occurring minerals, and in some cases, radioactive material, and can pick up substances resulting from the presence of animals or from human activity. Contaminants that may be present in source water before treatment include: Microbial contaminants, such as viruses and bacteria, which may come from sewage treatment plants, septic systems, agri- cultural livestock operations, and wildlife. Inorganic contaminants, such as salts and metals, which can be naturally-occurring or result from urban storm water runoff, industrial or domestic wastewater discharges, oil and gas pro- duction, mining, or farming. Pesticides and herbicides, which may come from a variety of sources such as agriculture, urban storm water runoff, and resi- dential uses. Organic chemical contaminants, including synthetic and vola- tile organic chemicals, which are by-products of industrial pro- cesses and petroleum production, and can also come from gas stations, urban storm water run off, and septic systems. Radioactive contaminants, which can be naturally-occurring or be the result of oil and gas production and mining activities. Where do we get our drinking water? Valley MUD # 2 has 3 sources of drinking water. Approximately 50% of our drinking wa- ter comes from the Resaca del Rancho Viejo which is fed by the Rio Grande river. Another 30% comes from a well on District property drilled into the gulf coast aquifer. This water is treated with a reverse osmosis system before it is blended with water from the surface water plant and pumped into the distribution system. The remaining water comes from the Southmost Regional Water Authority, a regional groundwater desalinization plant . En Español Este informe incluye información importante sobre el agua potable. Si tiene preguntas o comentarios sobre éste informe en español, favor de llamar al tel. (956) 350-4136 para hablar con una persona bilingüe en español.

Upload: others

Post on 23-Jul-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2018 Annual Drinking Water Quality Report

2018 Annual Drinking Water Quality Report VALLEY MUNICIPAL UTILTY DISTRICT NO. 2 100 Hidalgo Avenue, Rancho Viejo, Texas (956) 350-4136

Special Notice for the ELDERLY, INFANTS, CANCER PATIENTS, people with HIV/AIDS or other immune problems:

Some people may be more vulnerable to

contaminants in drinking water than the

general population. Immuno-

compromised persons such as persons

with cancer undergoing chemotherapy,

persons who have undergone organ trans-

plants, people with HIV/AIDS or other

immune system disorders, some elderly,

and infants can be particularly at risk from

infections. These people should seek ad-

vice about drinking water from their

health care providers. The EPA/Centers

for Disease Control and Prevention

(CDC) guidelines on appropriate means to

lessen the risk of infection by Cryptospor-

idium and other microbial contaminants

are available from the Safe Drinking Wa-

ter Hotline (1-800-426-4791).

Public Participation

Opportunities Date: July 16, 2019 Time: 9:00 AM Location: 100 Hidalgo Phone No: (956) 350-4136

Valley MUD #2 has regular board meetings on

the third Tuesday of every month. These meet-

ings are open to the public. To request an agen-

da , please call us.

Our Drinking Water Meets or Exceeds All

Federal (EPA) Drinking Water Requirements

This report is a summary of the quality of the water we provide our

customers. The analysis was made by using the data from the most

recent U.S. Environmental Protection Agency (EPA) required tests

and is presented in the attached pages. We hope this information

helps you become more knowledgeable about what's in your drink-

ing water.

SOURCES OF DRINKING WATER: The sources of drinking wa-

ter (both tap water and bottled water) include rivers, lakes, streams,

ponds, reservoirs, springs, and wells. As water travels over the sur-

face of the land or through the ground, it dissolves naturally-

occurring minerals, and in some cases, radioactive material, and can

pick up substances resulting from the presence of animals or from

human activity. Contaminants that may be present in source water

before treatment include:

Microbial contaminants, such as viruses and bacteria, which

may come from sewage treatment plants, septic systems, agri-

cultural livestock operations, and wildlife.

Inorganic contaminants, such as salts and metals, which can be

naturally-occurring or result from urban storm water runoff,

industrial or domestic wastewater discharges, oil and gas pro-

duction, mining, or farming.

Pesticides and herbicides, which may come from a variety of

sources such as agriculture, urban storm water runoff, and resi-

dential uses.

Organic chemical contaminants, including synthetic and vola-

tile organic chemicals, which are by-products of industrial pro-

cesses and petroleum production, and can also come from gas

stations, urban storm water run off, and septic systems.

Radioactive contaminants, which can be naturally-occurring or

be the result of oil and gas production and mining activities.

Where do we get our drinking water? Valley MUD # 2 has 3

sources of drinking water. Approximately 50% of our drinking wa-

ter comes from the Resaca del Rancho Viejo which is fed by the

Rio Grande river. Another 30% comes from a well on District

property drilled into the gulf coast aquifer. This water is treated

with a reverse osmosis system before it is blended with water from

the surface water plant and pumped into the distribution system.

The remaining water comes from the Southmost Regional Water

Authority, a regional groundwater desalinization plant .

En Español Este informe incluye información importante sobre el agua potable. Si tiene preguntas o comentarios sobre éste informe en español, favor de llamar al tel. (956) 350-4136 para hablar con una persona bilingüe en español.

Page 2: 2018 Annual Drinking Water Quality Report

ALL drinking water may contain contaminants. Drinking water, including bottled water, may reasonably be expected to contain at least small

amounts of some contaminants. The presence of contaminants does not necessarily indicate that

water poses a health risk. More information about contaminants and potential health effects can be

obtained by calling the EPA’s Safe Drinking Water Hotline (1-800-426-4791).

Secondary Constituents Many constituents (such as calcium, sodium, or iron) which are often found in drinking water, can

cause taste, color, and odor problems. The taste and odor constituents are called secondary constitu-

ents and are regulated by the State of Texas, not the EPA. These constituents are not causes for

health concern. Therefore, secondary constituents are not required to be reported in this document

but they may greatly affect the appearance and taste of your water.

DEFINITIONS Maximum Contaminant Level (MCL)

The highest permissible level of a contaminant in drinking water. MCLs are set as close to the MCLGs as

feasible using the best available treatment technology.

Maximum Contaminant Level Goal (MCLG)

The level of a contaminant in drinking water below which there is no known or expected health risk.

MCLGs allow for a margin of safety.

Maximum Residual Disinfectant Level (MRDL)

The highest level of disinfectant allowed in drinking water. There is convincing evidence that addition of a

disinfectant is necessary for control of microbial contaminants.

Maximum Residual Disinfectant Level Goal (MRDLG)

The level of a drinking water disinfectant below which there is no known or expected risk to health.

MRDLGs do not reflect the benefits of the use of disinfectants to control microbial contamination.

Treatment Technique (TT)

A required process intended to reduce the level of a contaminant in drinking water.

Action Level (AL)

The concentration of a contaminant which, if exceeded, triggers treatment or other requirements which a

water system must follow.

ABBREVIATIONS

NTU -Nephelometric Turbidity Units

MFL -million fibers per liter (a measure of asbestos)

pCi/L -picocuries per liter (a measure of radioactivity)

ppm - par ts per million, or milligrams per liter (mg/L)

ppb -parts per billion, or micrograms per liter (μg/L)

ppt -parts per trillion, or nanograms per liter

ppq -parts per quadrillion, or picograms per liter About The Following Pages

The pages that follow list all of the federally regulated or monitored contaminants which have been found in

your drinking water. The U.S. EPA requires water systems to test for up to 97 contaminants.

The TCEQ completed an assessment of your water and results indicate that some of your sources are susceptible to certain contaminants. The sampling requirements for your water system are based on this susceptibility and previous sampling data. Any detections of this contaminants may be found in this Consumer Confidence Report. For more information on source water assessments and protection efforts at our system, contact Mr. Javier Ramos at (956) 350-4136 or write us at 100 Hi-dalgo Avenue, Rancho Viejo, Tx. 78575

Page 3: 2018 Annual Drinking Water Quality Report

Inorganic Contaminants

MAXIMUM RESIDUAL DISINFECTANT LEVEL Chlorine / Chloramine Residual Disinfection Byproducts

Collection Date

Substance (UNIT OF

MEASURE)

Highest Level

Detected

Range of Levels De-

tected

MCL MCLG Violation Source of Constituent

2018 Arsenic (ppb)

2.5 2.5 10.0 0 N Erosion of natural deposits; Runoff from or-chards; Runoff from glass and electronics production wastes

2018 Barium (ppm)

0.1 0.1 2.0 2.0 N Discharge of drilling wastes; Discharge from metal refineries; erosion of natural deposits.

2018 Fluoride (ppm)

0.47 0.47 4 4 N Erosion of natural deposits; Water additive which promotes strong teeth; Discharge from fertilizer and aluminum factories.

2018 Nitrate{measured as Nitrogen} (ppm)

0.08 0.01-0.08 10 10 N Runoff from fertilizer use; Leaching from sep-tic tank sewage; Erosion of natural deposits.

2018 Cyanide (ppb)

160 160 200 200 N Discharge from plastic and fertilizer factories; Discharge from steel / metal factories.

Radioactive Contami-

nants (Unit of Measure)

Highest Level

Detected

Range of Levels Detect-

ed

MCL MCLG Violation Source of Constituent

2018 Combined Radium 226 & 228 (pCi/L)

1.5 1.5-1.5 5 5 N Erosion of Natural Deposits

2018 Xylenes (ppb)

0.6 0.6 10 10 N Discharge from petroleum factories, Discharge from Chemical factories

2018 Average Level of Quaterly data

Maximum Detected

Minimum Detected

MRDL MRDLG

Chloramine 2.21 2.76 1.68 4.0 <4.0 Disinfectant used to control microbes

Contaminant Highest Level

Range of Level

MCLG MCL Violation Source of Contaminant Unit of Measure

2018 Haloacetic Acids (HAA5)

11.0 8.0 - 11.0

60 N Byproduct of Drinking Water Disinfection

ppb

2018 Total Trihalome-thanes

27.0 21.0 - 27.0 80 N Byproduct of Drinking Water Disinfection

ppb

Year Constituent Average Level

Units of Measure

Reason for Monitoring Maximum Level

Minimum Level

MCL

2018 Chloroform 5.68 ppb Unregulated contaminant monitoring helps EPA to determine where certain contaminants occur and whether it needs to regulate those contami-nants

7.8 1.0 100

2018 Bromoform 5.24 ppb 14.1 1.0 100

2018 Bromodichloromethane 10.5 ppb 20.0 1.0 100

2018 Dibromochloromethane 12.08 ppb 35.0 1.0 100

Page 4: 2018 Annual Drinking Water Quality Report

Lead and Copper

Turbidity

Total Organic Carbon The Percentage of Total Organic Carbon (TOC) removal was measured each month and the system met all TOC removal requirements set, unless a TOC violation is noted on this report.

COLIFORMS

The Total Coliform Rule requires water systems to meet a stricter limit for coliform bacteria. When coliform bacteria are found, special follow-up tests are done to determine if harmful bacteria are present in the water supply. If this limit is exceeded, the water supplier must notify the public by newspaper, television or radio. Fecal coliform (mostly E-coli), is a portion of the coliform bacteria group originating in the intestinal tract of warm-blooded animals that passes into the environment as feces. Fecal coliform is often used as an indicator of the fecal contamination of domestic water sup-ply.

Violations

Year Constituent MCLG Action Level (AL)

Units Violation Source of Constituent 90th Percentile

#Sites Over AL

2017 Copper 1.3 1.3 Ppm N Corrosion of household plumbing systems, erosion of natural deposits, leaching from wood preservatives.

0.0268 0

2017 Lead 0 15 Ppb N Corrosion of household plumbing systems, erosion of natural deposits

0.763 0

Limit (Treatment Technique)

Level Detected Likely Source of Contamination

Highest Single Measurement 1 NTU 5 NTU Soil runoff

Lowest monthly % meeting Limit 0 . 3 NTU 17% Soil runoff

Interim Enhanced SWTR

The Interim Enhanced Surface Water Treatment Rule improves control of microbial contaminants, particularly Cryptosporidium, in systems using surface water, or ground water under the direct influence of surface water. The rule builds upon the treatment technique requirements of the Surface Water Treatment Rule.

Violation Type Violation Begin Violation End Violation Explanation

MONTHLY COMB FLTR EFFLUENT (IESWTR/LT1) 09/01/2018 09/30/2018 Turbidity levels, though relatively low, exceeded a standard for the month indicated. Turbidity (cloudiness) levels are used to measure effective filtration of drinking water.

MONTHLY COMB FLTR EFFLUENT (IESWTR/LT1) 10/01/2018 10/31/2018

SINGLE COMB FLTR EFFLUENT (IESWTR/LT1) 09/30/2018 09/30/2018 One turbidity measurement exceeded a standard for the month indicated. Turbidity (cloudiness) levels are used to measure effective filtration of drinking water.

SINGLE COMB FLTR EFFLUENT (IESWTR/LT1) 10/01/2018 10/01/2018

Maximum Con-taminant Level

Goal

Total Coliform Maxi-mum Contaminant

Level

Highest No. of Positive

Fecal Coliform or E. Coli Maximum Con-

taminant Level

Total No. of Positive E. Coli or Fecal

Coliform Samples

Violation Likely Source of Contamination

0 1 positive monthly sample.

1 0 N Naturally present in the environment.

Turbidity has no health effects. However, turbidity can interfere with disinfection and provide a medium for microbial growth. Tur-bidity may indicate the presence of disease-causing organisms. These organisms include bacteria, viruses, and parasites that can cause symptoms such as nausea, cramps, diarrhea and associated headaches.

Page 5: 2018 Annual Drinking Water Quality Report

Year (Range)

Inorganic Con-taminants

Highest Level Detected

Range of levels detected

MCLG MCL Unit of measure

Likely Source of Constituent

2018 Aluminum 0.196 0.196 0.2 ppm Abundant naturally Occurring Element

2018 Alkalinity Bicarbonate

133 133

NA ppm Corrosion of carbonated rocks such as limestone

2018 Calcium 71.3 71.3 NA ppm Abundant Naturally Occurring Element

2018 Chloride 170 170 300 ppm Abundant naturally occurring element; used in water purification; byproduct of oil field activity.

2017 Copper 0.0038 0.0038 NA ppm Corrosion of household plumbing sys-tems; erosion of natural deposits, leaching from wood preservatives

2018 Silver 0.01 0.01 0.01 0.01 ppm Erosion of natural deposits

2018 Iron 0.01 0.01 0.01 .3 ppm Erosion of natural deposits; iron or steel water delivery equipment or facilities.

2018 Magnesium 23.7 23.7 NA ppm Abundant naturally occurring element

2018 Manganese 0.0021 0.0021 0.001 0.05 ppm Abundant naturally occurring element

2018 Nickel 0.0019 0.0019 NA ppm Erosion of Natural Deposits

2018 pH average 8.34 7.26-8.34 8.34 >6 : 9< Positive Hidrogn

Ions

Corrosive measurement of water

2018 Sodium 148 148

NA ppm Erosion of natural deposits, byproduct of oil field activity.

2017-2018

Sulfate 261 256-261 300 300 ppm Naturally Occurring;, common industrial byproduct, byproduct of oil field activity

2017-2018

Total Alkalinity 109 76-109 NA ppm Naturally occurring soluble mineral salts.

2018 Total Dissolved Solids

754 754 1000 1000 ppm Total dissolved mineral constituents in water.

2018 Total Hardness as CaCO3

184 184 NA ppm Naturally occurring calcium

2018 Zinc 0.005 0.005 0.005 5 ppm Moderately abundant naturally occurring element used in the metal industry.

Secondary and Other Constituents - Not Regulated

State Water Loss Audit In the water loss audit submitted to Texas Water Development Board for the time period of January through December 2018, our system lost an estimated 33,304,338 (18.43 %) of water through main breaks, leaks and other causes. If you have any questions about the water loss audit please call 956-350-4136

Page 6: 2018 Annual Drinking Water Quality Report