1 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted in yellow. SECTION 801 - GENERAL 801.1 Scope. This chapter shall govern matters concerning indirect waste piping and special wastes. This chapter shall further control matters concerning food-handling establishments, sterilizers, clear-water wastes, waste, swimming pools, methods of providing air breaks or air gaps, and neutralizing devices for corrosive wastes. 801.2 Protection. Devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that discharge to the drainage system, shall be provided with protection against backflow, flooding, fouling, contamination and stoppage of the drain. SECTION 802 - INDIRECT WASTES 802.1 Where required. Food-handling equipment, in other than dwelling units, clear-water waste, dishwashing machines and utensils, pots, pans and dishwashing sinks shall discharge through an indirect waste pipe as specified in Sections802.1.1 through 802.1.8. Health-care related fixtures, devices and equipment shall discharge to the drainage system through an indirect waste pipe by means of an air gap in accordance with this chapter and Section713.3. Fixtures not required by this section to be indirectly connected shall be directly connected to the plumbing system in accordance with Chapter 7. 802.1.1 Food handling. Equipment and fixtures utilized for the storage, preparation and handling of food shall discharge through an indirect waste pipe by means of an air gap. Each well of a multiple- compartment sink shall discharge independently to a waste receptor.

Upload: others

Post on 03-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

1

2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8

INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted in yellow. SECTION801-GENERAL

801.1Scope.

Thischaptershallgovernmattersconcerningindirectwastepipingandspecialwastes.This

chaptershallfurthercontrolmattersconcerningfood-handlingestablishments,sterilizers,

clear-waterwastes,waste,swimmingpools,methodsofprovidingairbreaksorairgaps,and

neutralizingdevicesforcorrosivewastes.

801.2Protection.

Devices,appurtenances,appliancesandapparatusintendedtoservesomespecialfunction,

suchassterilization,distillation,processing,cooling,orstorageoficeorfoods,andthat

dischargetothedrainagesystem,shallbeprovidedwithprotectionagainstbackflow,flooding,

fouling,contaminationandstoppageofthedrain.

SECTION802-INDIRECTWASTES

802.1Whererequired.

Food-handlingequipment,inotherthandwellingunits,clear-waterwaste,dishwashing

machinesandutensils,pots,pansanddishwashingsinksshalldischargethroughanindirect

wastepipeasspecifiedinSections802.1.1through802.1.8.Health-carerelatedfixtures,devices

andequipmentshalldischargetothedrainagesystemthroughanindirectwastepipebymeans

ofanairgapinaccordancewiththischapterandSection713.3.Fixturesnotrequiredbythis

sectiontobeindirectlyconnectedshallbedirectlyconnectedtotheplumbingsystemin

accordancewithChapter7.

802.1.1Foodhandling.

Equipmentandfixturesutilizedforthestorage,preparationandhandlingoffoodshall

dischargethroughanindirectwastepipebymeansofanairgap.Eachwellofamultiple-

compartmentsinkshalldischargeindependentlytoawastereceptor.

Page 2: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

2

802.1.2Floordrainsinfoodstorageareas.

Floordrainslocatedwithinwalk-inrefrigeratorsorfreezersinfoodserviceandfood

establishmentsshallbeindirectlyconnectedtothesanitarydrainagesystembymeans

ofanairgap.Whereafloordrainislocatedwithinanareasubjecttofreezing,thewaste

lineservingthefloordrainshallnotbetrappedandshallindirectlydischargeintoa

wastereceptorlocatedoutsideoftheareasubjecttofreezing.

Exception:Whereprotectedagainstbackflowbyabackwatervalve,suchfloor

drainsshallbeindirectlyconnectedtothesanitarydrainagesystembymeansof

anairbreakoranairgap.

802.1.3Potableclear-waterwaste.

Wheredevicesandequipment,suchassterilizersandreliefvalves,dischargepotable

watertothebuildingdrainagesystem,thedischargeshallbethroughanindirectwaste

pipebymeansofanairgap.

802.1.4Swimmingpools.

Wherewastewaterfromswimmingpools,backwashfromfiltersandwaterfrompool

deckdrainsdischargetothebuildingdrainagesystem,thedischargeshallbethroughan

indirectwastepipebymeansofanairgap.

802.1.5Nonpotableclear-waterwaste.

Wheredevicesandequipmentsuchasprocesstanks,filters,dripsandboilersdischarge

nonpotablewatertothebuildingdrainagesystem,thedischargeshallbethroughan

indirectwastepipebymeansofanairbreakoranairgap.

802.1.6Domesticdishwashingmachines.

Domesticdishwashingmachinesshalldischargeindirectlythroughanairgaporairbreak

intoawastereceptorinaccordancewithSection802.2,ordischargeintoawyebranch

fittingonthetailpieceofthekitchensinkorthedishwasherconnectionofafoodwaste

disposer.Thewastelineofadomesticdishwashingmachinedischargingintoakitchen

sinktailpieceorfoodwastedisposershallconnecttoadeck-mountedairgaporthe

wastelineshallriseandbesecurelyfastenedtotheundersideofthesinkrimor

counter.

Page 3: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

3

802.1.7Commercialdishwashingmachines.

Thedischargefromacommercialdishwashingmachineshallbethroughanairgaporair

breakintoawastereceptorinaccordancewithSection802.2.

802.1.8Foodutensils,dishes,potsandpanssinks.

Sinks,inotherthandwellingunits,usedforthewashing,rinsingorsanitizingofutensils,

dishes,pots,pansorservicewareusedinthepreparation,servingoreatingoffoodshall

dischargeindirectlythroughanairgaporanairbreaktothedrainagesystem.

802.2Installation.

Indirectwastepipingshalldischargethroughanairgaporairbreakintoawastereceptor.

Wastereceptorsshallbetrappedandventedandshallconnecttothebuildingdrainagesystem.

Indirectwastepipingthatexceeds30inches(762mm)indevelopedlengthmeasured

horizontally,or54inches(1372mm)intotaldevelopedlength,shallbetrapped.

Exception:Whereawastereceptorreceivesonlyclearwaterwasteanddoesnotdirectly

connecttoasanitarydrainagesystem,thereceptorshallnotrequireatrap.

802.2.1Airgap.

Theairgapbetweentheindirectwastepipeandthefloodlevelrimofthewaste

receptorshallbenotlessthantwicetheeffectiveopeningoftheindirectwastepipe.

802.2.2Airbreak.

Anairbreakshallbeprovidedbetweentheindirectwastepipeandthetrapsealofthe

wastereceptor.

802.3Wastereceptors.

Forotherthanhubdrainsthatreceiveonlyclear-waterwasteandstandpipes,aremovable

strainerorbasketshallcovertheoutletofwastereceptors.Wastereceptorsshallnotbe

installedinconcealedspaces.Wastereceptorsshallnotbeinstalledinplenums,crawlspaces,

attics,interstitialspacesaboveceilingsandbelowfloors.Readyaccessshallbeprovidedto

wastereceptors.

802.3.1Sizeofreceptors.

Awastereceptorshallbesizedforthemaximumdischargeofallindirectwastepipes

servedbythereceptor.Receptorsshallbeinstalledtopreventsplashingorflooding.

Page 4: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

4

802.3.2Hubdrains.

Ahubdrainshallbeintheformofahuborapipeextendingnotlessthan1inch(25

mm)aboveawater-imperviousfloor.

802.3.3Standpipes.

Standpipesshallbeindividuallytrapped.Standpipesshallextendnotlessthan18inches

(457mm)butnotgreaterthan42inches(1066mm)abovethetrapweir.Accessshallbe

providedtostandpipesanddrainsforrodding.

SECTION803-SPECIALWASTES

803.1Neutralizingdevicerequiredforcorrosivewastes.

Corrosiveliquids,spentacidsorotherharmfulchemicalsthatdestroyorinjureadrain,sewer,

soilorwastepipe,orcreatenoxiousortoxicfumesorinterferewithsewagetreatment

processesshallnotbedischargedintotheplumbingsystemwithoutbeingthoroughlydiluted,

neutralizedortreatedbypassingthroughanapproveddilutionorneutralizingdevice.Such

devicesshallbeautomaticallyprovidedwithasufficientsupplyofdilutingwaterorneutralizing

mediumsoastomakethecontentsnoninjuriousbeforedischargeintothedrainagesystem.

Thenatureofthecorrosiveorharmfulwasteandthemethodofitstreatmentordilutionshall

beapprovedpriortoinstallation.

803.2Systemdesign.

Achemicaldrainageandventsystemshallbedesignedandinstalledinaccordancewiththis

code.Chemicaldrainageandventsystemsshallbecompletelyseparatedfromthesanitary

systems.Chemicalwasteshallnotdischargetoasanitarydrainagesystemuntilsuchwastehas

beentreatedinaccordancewithSection803.1.

SECTION804-MATERIALS,JOINTSANDCONNECTIONS

804.1General.

Thematerialsandmethodsutilizedfortheconstructionandinstallationofindirectwastepipes

andsystemsshallcomplywiththeapplicableprovisionsofChapter7.

Page 5: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

5

2015 IPC CODE - CHAPTER 9 VENTS

SECTION901-GENERAL

901.1Scope.

Theprovisionsofthischaptershallgovernthematerials,design,constructionandinstallationof

ventsystems.

901.2Trapsealprotection.

Theplumbingsystemshallbeprovidedwithasystemofventpipingthatwillpermitthe

admissionoremissionofairsothatthesealofanyfixturetrapshallnotbesubjectedtoa

pressuredifferentialofmorethan1inchofwatercolumn(249Pa).

901.2.1Ventingrequired.

Trapsandtrappedfixturesshallbeventedinaccordancewithoneoftheventing

methodsspecifiedinthischapter.

901.3Chemicalwasteventsystems.

Theventsystemforachemicalwastesystemshallbeindependentofthesanitaryventsystem

andshallterminateseparatelythroughtherooftotheoutdoorsortoanairadmittancevalve

thatcomplieswithASSE1049.Airadmittancevalvesforchemicalwastesystemsshallbe

constructedofmaterialsapprovedinaccordancewithSection702.5andshallbetestedfor

chemicalresistanceinaccordancewithASTMF1412.

901.4Uselimitations.

Theplumbingventsystemshallnotbeutilizedforpurposesotherthantheventingofthe

plumbingsystem.

901.5Tests.

TheventsystemshallbetestedinaccordancewithSection312.

901.6Engineeredsystems.

EngineeredventingsystemsshallconformtotheprovisionsofSection919.

Page 6: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

6

SECTION902-MATERIALS

902.1Vents.

Thematerialsandmethodsutilizedfortheconstructionandinstallationofventingsystems

shallcomplywiththeapplicableprovisionsofSection702.

902.2Sheetcopper.

SheetcopperforventpipeflashingsshallconformtoASTMB152andshallweighnotlessthan

8ouncespersquarefoot(2.5kg/m2).

902.3Sheetlead.

Sheetleadforventpipeflashingsshallweighnotlessthan3poundspersquarefoot(15kg/m2)

forfield-constructedflashingsandnotlessthan2½poundspersquarefoot(12kg/m2)for

prefabricatedflashings.

SECTION903-VENTTERMINALS

903.1Roofextension.

Openventpipesthatextendthrougharoofshallbeterminatednotlessthan[NUMBER]inches

(mm)abovetheroof.Wherearoofistobeusedforassemblyorasapromenade,observation

deck,sunbathingdeckorsimilarpurposes,openventpipesshallterminatenotlessthan7feet

(2134mm)abovetheroof.

903.2Frostclosure.

Wherethe97.5-percentvalueforoutsidedesigntemperatureis0°F(-18°C)orless,vent

extensionsthrougharooforwallshallbenotlessthan3inches(76mm)indiameter.Any

increaseinthesizeoftheventshallbemadenotlessthan1foot(305mm)insidethethermal

envelopeofthebuilding.

903.3Flashings.

Thejunctureofeachventpipewiththerooflineshallbemadewatertightbyanapproved

flashing.

903.4Prohibiteduse.

Aventterminalshallnotbeusedforanypurposeotherthanaventterminal.

Page 7: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

7

903.5Locationofventterminal.

Anopenventterminalfromadrainagesystemshallnotbelocateddirectlybeneathanydoor,

openablewindow,orotherairintakeopeningofthebuildingorofanadjacentbuilding,and

anysuchventterminalshallnotbewithin10feet(3048mm)horizontallyofsuchanopening

unlessitis3feet(914mm)ormoreabovethetopofsuchopening.

903.6Extensionthroughthewall.

Ventterminalsextendingthroughthewallshallterminateatapointnotlessthan10feet(3048

mm)fromalotlineandnotlessthan10feet(3048mm)aboveaveragegroundlevel.Vent

terminalsshallnotterminateundertheoverhangofastructurewithsoffitvents.Sidewallvent

terminalsshallbeprotectedtopreventbirdsorrodentsfromenteringorblockingthevent

opening.

903.7Extensionoutsideastructure.

Inclimateswherethe97.5percentvalueforoutsidedesigntemperatureislessthan0°F(-18°C),

ventpipesinstalledontheexteriorofthestructureshallbeprotectedagainstfreezingby

insulation,heatorboth.

SECTION904-OUTDOORVENTEXTENSIONS

904.1Requiredventextension.

Theventsystemservingeachbuildingdrainshallhavenotlessthanoneventpipethatextends

totheoutdoors.

904.1.1Installation.

Therequiredventshallbeadryventthatconnectstothebuildingdrainoranextension

ofadrainthatconnectstothebuildingdrain.Suchventshallnotbeanislandfixture

ventasallowedbySection916.

904.1.2Size.

TherequiredventshallbesizedinaccordancewithSection906.2basedontherequired

sizeofthebuildingdrain.

Page 8: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

8

904.2Ventstackrequired.

Aventstackshallberequiredforeverydrainagestackthathasfivebranchintervalsormore.

Exception:DrainagestacksinstalledinaccordancewithSection913.

904.3Venttermination.

Ventstacksorstackventsshallterminateoutdoorstotheopenairortoastack-typeair

admittancevalveinaccordancewithSection918.

904.4Ventconnectionatbase.

Ventstacksshallconnecttothebaseofthedrainagestack.Theventstackshallconnectator

belowthelowesthorizontalbranch.Wheretheventstackconnectstothebuildingdrain,the

connectionshallbelocateddownstreamofthedrainagestackandwithinadistanceof10times

thediameterofthedrainagestack.

904.5Ventheaders.

Stackventsandventstacksconnectedintoacommonventheaderatthetopofthestacksand

extendingtotheopenairatonepointshallbesizedinaccordancewiththerequirementsof

Section906.1.Thenumberoffixtureunitsshallbethesumofallfixtureunitsonallstacks

connectedthereto,andthedevelopedlengthshallbethelongestventlengthfromthe

intersectionatthebaseofthemostdistantstacktotheventterminalintheopenair,asa

directextensionofonestack.

SECTION905-VENTCONNECTIONSANDGRADES

905.1Connection.

Individual,branchandcircuitventsshallconnecttoaventstack,stackvent,airadmittance

valveorextendtotheopenair.

905.2Grade.

Ventandbranchventpipesshallbesogradedandconnectedastodrainbacktothedrainage

pipebygravity.

905.3Ventconnectiontodrainagesystem.

Everydryventconnectingtoahorizontaldrainshallconnectabovethecenterlineofthe

horizontaldrainpipe.

Page 9: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

9

905.4Verticalriseofvent.

Everydryventshallriseverticallytoapointnotlessthan6inches(152mm)abovetheflood

levelrimofthehighesttraportrappedfixturebeingvented.

Exception:Ventsforinterceptorslocatedoutdoors.

905.5Heightabovefixtures.

Aconnectionbetweenaventpipeandaventstackorstackventshallbemadeatnotlessthan

6inches(152mm)abovethefloodlevelrimofthehighestfixtureservedbythevent.

Horizontalventpipesformingbranchvents,reliefventsorloopventsshallbelocatednotless

than6inches(152mm)abovethefloodlevelrimofthehighestfixtureserved.

905.6Ventforfuturefixtures.

Wherethedrainagepipinghasbeenroughed-inforfuturefixtures,arough-inconnectionfora

ventshallbeinstalled.Theventsizeshallbenotlessthanone-halfthediameteroftherough-in

draintobeserved.Theventrough-inshallconnecttotheventsystem,orshallbeventedby

othermeansasprovidedforinthischapter.Theconnectionshallbeidentifiedtoindicatethat

itisavent.

Page 10: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

10

SECTION906-VENTPIPESIZING

906.1Sizeofstackventsandventstacks.

Theminimumrequireddiameterofstackventsandventstacksshallbedeterminedfromthe

developedlengthandthetotalofdrainagefixtureunitsconnectedtheretoinaccordancewith

Table906.1,butinnocaseshallthediameterbelessthanone-halfthediameterofthedrain

servedorlessthan1¼inches(32mm).

Page 11: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

11

906.2Ventsotherthanstackventsorventstacks.

Thediameterofindividualvents,branchvents,circuitventsandreliefventsshallbenotless

thanone-halftherequireddiameterofthedrainserved.Therequiredsizeofthedrainshallbe

determinedinaccordancewithTable710.1(2).Ventpipesshallnotbelessthan1¼inches(32

mm)indiameter.Ventsexceeding40feet(12192mm)indevelopedlengthshallbeincreased

byonenominalpipesizefortheentiredevelopedlengthoftheventpipe.Reliefventsforsoil

andwastestacksinbuildingshavingmorethan10branchintervalsshallbesizedinaccordance

withSection908.2.

906.3Developedlength.

Thedevelopedlengthofindividual,branch,circuitandreliefventsshallbemeasuredfromthe

farthestpointofventconnectiontothedrainagesystemtothepointofconnectiontothevent

stack,stackventorterminationoutsideofthebuilding.

906.4Multiplebranchvents.

Wheremultiplebranchventsareconnectedtoacommonbranchvent,thecommonbranch

ventshallbesizedinaccordancewiththissectionbasedonthesizeofthecommonhorizontal

drainagebranchthatisorwouldberequiredtoservethetotaldrainagefixtureunitloadbeing

vented.

Page 12: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

12

906.5Sumpvents.

SumpventsizesshallbedeterminedinaccordancewithSections906.5.1and906.5.2.

906.5.1Sewagepumpsandsewageejectorsotherthanpneumatic.

Drainagepipingbelowsewerlevelshallbeventedinthesamemannerasthatofa

gravitysystem.Buildingsumpventsizesforsumpswithsewagepumpsorsewage

ejectors,otherthanpneumatic,shallbedeterminedinaccordancewithTable906.5.1.

906.5.2Pneumaticsewageejectors.

Theairpressurereliefpipefromapneumaticsewageejectorshallbeconnectedtoan

independentventstackterminatingasrequiredforventextensionsthroughtheroof.

Thereliefpipeshallbesizedtorelieveairpressureinsidetheejectortoatmospheric

pressure,butshallbenotlessthaninches1¼inches(32mm)insize.

Page 13: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

13

SECTION907-VENTSFORSTACKOFFSETS

907.1Ventforhorizontaloffsetofdrainagestack.

Horizontaloffsetsofdrainagestacksshallbeventedwherefiveormorebranchintervalsare

locatedabovetheoffset.Theoffsetshallbeventedbyventingtheuppersectionofthe

drainagestackandthelowersectionofthedrainagestack.

907.2Uppersection.

Theuppersectionofthedrainagestackshallbeventedasaseparatestackwithaventstack

connectioninstalledinaccordancewithSection904.4.Theoffsetshallbeconsideredthebase

ofthestack.

907.3Lowersection.

Thelowersectionofthedrainagestackshallbeventedbyayokeventconnectingbetweenthe

offsetandthenextlowerhorizontalbranch.Theyokeventconnectionshallbepermittedtobe

averticalextensionofthedrainagestack.Thesizeoftheyokeventandconnectionshallbea

minimumofthesizerequiredfortheventstackofthedrainagestack.

SECTION908-RELIEFVENTS-STACKSOFMORETHAN10BRANCHINTERVALS

908.1Whererequired.

Soilandwastestacksinbuildingshavingmorethan10branchintervalsshallbeprovidedwitha

reliefventateachtenthintervalinstalled,beginningwiththetopfloor.

908.2Sizeandconnection.

Thesizeofthereliefventshallbeequaltothesizeoftheventstacktowhichitconnects.The

lowerendofeachreliefventshallconnecttothesoilorwastestackthroughawyebelowthe

horizontalbranchservingthefloor,andtheupperendshallconnecttotheventstackthrougha

wyenotlessthan3feet(914mm)abovethefloor.

Page 14: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

14

SECTION909-FIXTUREVENTS

909.1Distanceoftrapfromvent.

Eachfixturetrapshallhaveaprotectingventlocatedsothattheslopeandthedeveloped

lengthinthefixturedrainfromthetrapweirtotheventfittingarewithintherequirementsset

forthinTable909.1.

Exception:The

developed

lengthofthe

fixturedrain

fromthetrap

weirtothe

ventfittingfor

self-siphoning

fixtures,such

aswaterclosets,shallnotbelimited.

909.2Ventingoffixturedrains.

Thetotalfallinafixturedrainduetopipeslopeshallnotexceedthediameterofthefixture

drain,norshalltheventconnectiontoafixturedrain,exceptforwaterclosets,bebelowthe

weirofthetrap.

909.3Crownvent.

Aventshallnotbeinstalledwithintwopipediametersofthetrapweir.

SECTION910-INDIVIDUALVENT

910.1Individualventpermitted.

Eachtrapandtrappedfixtureispermittedtobeprovidedwithanindividualvent.Theindividual

ventshallconnecttothefixturedrainofthetraportrappedfixturebeingvented.

Page 15: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

15

SECTION911-COMMONVENT

911.1Individualventascommonvent.

Anindividualventispermittedtoventtwotrapsortrappedfixturesasacommonvent.The

trapsortrappedfixturesbeingcommonventedshallbelocatedonthesamefloorlevel.

911.2Connectionatthesamelevel.

Wherethefixturedrainsbeingcommonventedconnectatthesamelevel,theventconnection

shallbeattheinterconnectionofthefixturedrainsordownstreamoftheinterconnection.

911.3Connectionatdifferentlevels.

Wherethefixturedrainsconnectatdifferentlevels,theventshallconnectasavertical

extensionoftheverticaldrain.Theverticaldrainpipeconnectingthetwofixturedrainsshallbe

consideredtheventfor

thelowerfixturedrain,

andshallbesizedin

accordancewithTable

911.3.Theupperfixture

shallnotbeawater

closet.

SECTION912-WETVENTING

912.1Horizontalwetventpermitted.

Anycombinationoffixtureswithintwobathroomgroupslocatedonthesamefloorlevelis

permittedtobeventedbyahorizontalwetvent.Thewetventshallbeconsideredtheventfor

thefixturesandshallextendfromtheconnectionofthedryventalongthedirectionoftheflow

inthedrainpipetothemostdownstreamfixturedrainconnectiontothehorizontalbranch

drain.Eachwet-ventedfixturedrainshallconnectindependentlytothehorizontalwetvent.

Onlythefixtureswithinthebathroomgroupsshallconnecttothewet-ventedhorizontalbranch

drain.Anyadditionalfixturesshalldischargedownstreamofthehorizontalwetvent.

Page 16: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

16

912.1.1Verticalwetventpermitted.

Anycombinationoffixtureswithintwobathroomgroupslocatedonthesamefloorlevel

ispermittedtobeventedbyaverticalwetvent.Theverticalwetventshallbe

consideredtheventforthefixturesandshallextendfromtheconnectionofthedry

ventdowntothelowestfixturedrainconnection.Eachwet-ventedfixtureshallconnect

independentlytotheverticalwetvent.Waterclosetdrainsshallconnectatthesame

elevation.Otherfixturedrainsshallconnectaboveoratthesameelevationasthewater

closetfixturedrains.Thedry-ventconnectiontotheverticalwetventshallbean

individualorcommonventservingoneortwofixtures.

912.2Dryventconnection.

Therequireddry-ventconnectionforwet-ventedsystemsshallcomplywithSections912.2.1

and912.2.2.

912.2.1Horizontalwetvent.

Thedry-ventconnectionforahorizontalwet-ventsystemshallbeanindividualventora

commonventforanybathroomgroupfixture,exceptanemergencyfloordrain.Where

thedry-ventconnectstoawaterclosetfixturedrain,thedrainshallconnecthorizontally

tothehorizontalwet-ventsystem.Notmorethanonewet-ventedfixturedrainshall

dischargeupstreamofthedry-ventedfixturedrainconnection.

912.2.2Verticalwetvent.

Thedry-ventconnectionforaverticalwet-ventsystemshallbeanindividualventor

commonventforthemostupstreamfixturedrain.

912.3Size.

Thedryventservingthewetventshallbesizedbasedonthelargestrequireddiameterofpipe

withinthewet-ventsystem

servedbythedryvent.Thewet

ventshallbeofasizenotless

thanthatspecifiedinTable912.3,

basedonthefixtureunit

dischargetothewetvent.

Page 17: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

17

SECTION913-WASTESTACKVENT

913.1Wastestackventpermitted.

Awastestackshallbeconsideredaventforallofthefixturesdischargingtothestackwhere

installedinaccordancewiththerequirementsofthissection.

913.2Stackinstallation.

Thewastestackshallbevertical,andbothhorizontalandverticaloffsetsshallbeprohibited

betweenthelowestfixturedrainconnectionandthehighestfixturedrainconnection.Fixture

drainsshallconnectseparatelytothewastestack.Thestackshallnotreceivethedischargeof

waterclosetsorurinals.

913.3Stackvent.

Astackventshallbeprovidedforthewastestack.Thesizeofthestackventshallbenotless

thanthesizeofthewastestack.Offsetsshallbepermittedinthestackvent,shallbelocatednot

lessthan6inches(152mm)abovethefloodlevelofthehighestfixtureandshallbein

accordancewithSection905.2.Thestackventshallbepermittedtoconnectwithother

stackventsandventstacksinaccordancewithSection904.5.

913.4Wastestacksize.

Thewastestackshallbesized

basedonthetotaldischargetothe

stackandthedischargewithina

branchintervalinaccordancewith

Table913.4.Thewastestackshall

bethesamesizethroughoutits

length.

SECTION914-CIRCUITVENTING

914.1Circuitventpermitted.

Amaximumofeightfixturesconnectedtoahorizontalbranchdrainshallbepermittedtobe

circuitvented.Eachfixturedrainshallconnecthorizontallytothehorizontalbranchbeing

circuitvented.Thehorizontalbranchdrainshallbeclassifiedasaventfromthemost

Page 18: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

18

downstreamfixturedrainconnectiontothemostupstreamfixturedrainconnectiontothe

horizontalbranch.

914.1.1Multiplecircuit-ventedbranches.

Circuit-ventedhorizontalbranchdrainsarepermittedtobeconnectedtogether.Each

groupofamaximumofeightfixturesshallbeconsideredaseparatecircuitventand

shallconformtotherequirementsofthissection.

914.2Ventconnection.

Thecircuitventconnectionshallbelocatedbetweenthetwomostupstreamfixturedrains.The

ventshallconnecttothehorizontalbranchandshallbeinstalledinaccordancewithSection

905.Thecircuitventpipeshallnotreceivethedischargeofanysoilorwaste.

914.3Slopeandsizeofhorizontalbranch.

Theslopeoftheventsectionofthehorizontalbranchdrainshallbenotgreaterthanoneunit

verticalin12unitshorizontal(8.3-percentslope).Theentirelengthoftheventsectionofthe

horizontalbranchdrainshallbesizedforthetotaldrainagedischargetothebranch.

914.3.1Sizeofmultiplecircuitvent.

Eachseparatecircuit-ventedhorizontalbranchthatisinterconnectedshallbesized

independentlyinaccordancewithSection914.3.Thedownstreamcircuit-vented

horizontalbranchshallbesizedforthetotaldischargeintothebranch,includingthe

upstreambranchesandthefixtureswithinthebranch.

914.4Reliefvent.

Areliefventshallbeprovidedforcircuit-ventedhorizontalbranchesreceivingthedischargeof

fourormorewaterclosetsandconnectingtoadrainagestackthatreceivesthedischargeof

soilorwastefromupperhorizontalbranches.

914.4.1Connectionandinstallation.

Thereliefventshallconnecttothehorizontalbranchdrainbetweenthestackandthe

mostdownstreamfixturedrainofthecircuitvent.Thereliefventshallbeinstalledin

accordancewithSection905.

Page 19: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

19

914.4.2Fixturedrainorbranch.

Thereliefventispermittedtobeafixturedrainorfixturebranchforfixtureslocated

withinthesamebranchintervalasthecircuit-ventedhorizontalbranch.Themaximum

dischargetoareliefventshallbefourfixtureunits.

914.5Additionalfixtures.

Fixtures,otherthanthecircuitventedfixtures,arepermittedtodischargetothehorizontal

branchdrain.Suchfixturesshallbelocatedonthesamefloorasthecircuit-ventedfixturesand

shallbeeitherindividuallyorcommonvented.

SECTION915-COMBINATIONWASTEANDVENTSYSTEM

915.1Typeoffixtures.

Acombinationwasteandventsystemshallnotservefixturesotherthanfloordrains,sinks,

lavatoriesanddrinkingfountains.Combinationwasteandventsystemsshallnotreceivethe

dischargefromafooddisposerorclinicalsink.

915.2Installation.

Theonlyverticalpipeofacombinationwasteandventsystemshallbetheconnectionbetween

thefixturedrainandthehorizontalcombinationwasteandventpipe.Theverticaldistanceshall

notexceed8feet(2438mm).

915.2.1Slope.

Theslopeofahorizontalcombinationwasteandventpipeshallnotexceedone-half

unitverticalin12units

horizontal(4-percent

slope)andshallnotbe

lessthanthatindicated

inTable704.1.

915.2.2Sizeandlength.

Thesizebethat

indicatedinTable

915.2.2unlimited.

Page 20: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

20

915.2.3Connection.

Thecombinationwasteandventsystemshallbeprovidedwithadryventconnectedat

anypointwithinthesystemorthesystemshallconnecttoahorizontaldrainthatserves

ventedfixtureslocatedonthesamefloor.Combinationwasteandventsystems

connectingtobuildingdrainsreceivingonlythedischargefromoneormorestacksshall

beprovidedwithadryvent.Theventconnectiontothecombinationwasteandvent

pipeshallextendverticallytoapointnotlessthan6inches(152mm)abovetheflood

levelrimofthehighestfixturebeingventedbeforeoffsettinghorizontally.

915.2.4Ventsize.

TheventshallbesizedforthetotaldrainagefixtureunitloadinaccordancewithSection

906.2.

915.2.5Fixturebranchordrain.

Thefixturebranchorfixturedrainshallconnecttothecombinationwasteandvent

withinadistancespecifiedinTable909.1.Thecombinationwasteandventpipeshallbe

consideredtheventforthefixture.

SECTION916-ISLANDFIXTUREVENTING

916.1 Limitation.

Islandfixtureventingshallnotbepermittedforfixturesotherthansinksandlavatories.

Residentialkitchensinkswithadishwasherwasteconnection,afoodwastedisposer,orboth,

incombinationwiththekitchensinkwaste,shallbepermittedtobeventedinaccordancewith

thissection.

916.2Ventconnection.

Theislandfixtureventshallconnecttothefixturedrainasrequiredforanindividualor

commonvent.Theventshallriseverticallytoabovethedrainageoutletofthefixturebeing

ventedbeforeoffsettinghorizontallyorverticallydownward.Theventorbranchventfor

multipleislandfixtureventsshallextendtoapointnotlessthan6inches(152mm)abovethe

highestislandfixturebeingventedbeforeconnectingtotheoutsideventterminal.

Page 21: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

21

916.3Ventinstallationbelowthefixturefloodlevelrim.

Theventlocatedbelowthefloodlevelrimofthefixturebeingventedshallbeinstalledas

requiredfordrainagepipinginaccordancewithChapter7,exceptforsizing.Theventshallbe

sizedinaccordancewithSection906.2.Thelowestpointoftheislandfixtureventshallconnect

fullsizetothedrainagesystem.Theconnectionshallbetoaverticaldrainpipeortothetop

halfofahorizontaldrainpipe.Cleanoutsshallbeprovidedintheislandfixtureventtopermit

roddingofallventpipinglocatedbelowthefloodlevelrimofthefixtures.Roddinginboth

directionsshallbepermittedthroughacleanout.

SECTION917-SINGLESTACKVENTSYSTEM

917.1Wherepermitted.

Adrainagestackshallserveasasinglestackventsystemwheresizedandinstalledin

accordancewithSections917.2through917.9.Thedrainagestackandbranchpipingshallbe

theventsforthedrainagesystem.Thedrainagestackshallhaveastackvent.

917.2Stacksize.

Drainagestacksshallbe

sizedinaccordancewith

Table917.2.Stacksshallbe

uniformlysizedbasedon

thetotalconnected

drainagefixtureunitload.

Thestackventshallbethe

samesizeasthedrainage

stack.A3-inch(76mm)stackshallservenotmorethantwowaterclosets.

917.3Branchsize.

Horizontalbranchesconnectingtoasinglestackventsystemshallbesizedinaccordancewith

Table710.1(2).Notmorethanonewaterclosetshalldischargeintoa3-inch(76mm)horizontal

branchatapointwithinadevelopedlengthof18inches(457mm)measuredhorizontallyfrom

thestack.Whereawaterclosetiswithin18inches(457mm)measuredhorizontallyfromthe

Page 22: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

22

stackandnotmorethanonefixturewithadrainsizeofnotmorethan1½inches(38mm)

connectstoa3-inch(76mm)horizontalbranch,thebranchdrainconnectiontothestackshall

bemadewithasanitarytee.

917.4Lengthofhorizontalbranches.

ThelengthofhorizontalbranchesshallconformtotherequirementsofSections917.4.1

through917.4.3.

917.4.1Waterclosetconnection.

Waterclosetconnectionsshallbenotgreaterthan4feet(1219mm)indeveloped

lengthmeasuredhorizontallyfromthestack.

Exception:Wheretheconnectionismadewithasanitarytee,themaximum

developedlengthshallbe8feet(2438mm).

917.4.2Fixtureconnections.

Fixturesotherthanwaterclosetsshallbelocatednotgreaterthan12feet(3657mm)in

developedlength,measuredhorizontallyfromthestack.

917.4.3Verticalpipinginbranch.

Thelengthofverticalpipinginafixturedrainconnectingtoahorizontalbranchshallnot

beconsideredincomputingthefixture'sdistanceindevelopedlengthmeasured

horizontallyfromthestack.

917.5Minimumverticalpipingsizefromfixture.

Theverticalportionofpipinginafixturedraintoahorizontalbranchshallbe2inches(51mm).

Theminimumsizeoftheverticalportionofpipingforawater-suppliedurinalorstandpipeshall

be3inches(76mm).Themaximumverticaldropshallbe4feet(1219mm).Fixturedrainsthat

arenotincreasedinsize,orhaveaverticaldropinexcessof4feet(1219mm),shallbe

individuallyvented.

917.6Additionalventingrequired.

Additionalventingshallbeprovidedwheremorethanonewaterclosetdischargestoa

horizontalbranchandwherethedistancefromafixturetraptothestackexceedsthelimitsin

Section917.4.Whereadditionalventingisrequired,thefixture(s)shallbeventedbyindividual

vents,commonvents,wetvents,circuitvents,oracombinationwasteandventpipe.Thedry

Page 23: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

23

ventextensionsfortheadditionalventingshallconnecttoabranchvent,ventstack,stackvent,

airadmittancevalve,orshallterminateoutdoors.

917.7Stackoffsets.

Wherefixturedrainsarenotconnectedbelowahorizontaloffsetinastack,ahorizontaloffset

shallnotberequiredtobevented.Wherehorizontalbranchesorfixturedrainsareconnected

belowahorizontaloffsetinastack,theoffsetshallbeventedinaccordancewithSection907.

Fixtureconnectionsshallnotbemadetoastackwithin2feet(610mm)aboveorbelowa

horizontaloffset.

917.8Prohibitedlowerconnections.

Stacksgreaterthan2branchintervalsinheightshallnotreceivethedischargeofhorizontal

branchesonthelowertwofloors.Thereshallbenoconnectionstothestackbetweenthe

lowertwofloorsandadistanceofnotlessthan10pipediametersdownstreamfromthebase

ofthesinglestackventedsystem.

917.9Sizingbuildingdrainsandsewers.

Thebuildingdrainandbuildingsewerreceivingthedischargeofasinglestackventsystemshall

besizedinaccordancewithTable710.1(1).

SECTION918-AIRADMITTANCEVALVES

918.1General.

Ventsystemsutilizingairadmittancevalvesshallcomplywiththissection.Stack-typeair

admittancevalvesshallconformtoASSE1050.Individualandbranchtypeairadmittancevalves

shallconformtoASSE1051.

918.2Installation.

Thevalvesshallbeinstalledinaccordancewiththerequirementsofthissectionandthe

manufacturer'sinstructions.AiradmittancevalvesshallbeinstalledaftertheDWVtesting

requiredbySection312.2or312.3hasbeenperformed.

918.3Wherepermitted.

Individual,branchandcircuitventsshallbepermittedtoterminatewithaconnectiontoan

individualorbranch-typeairadmittancevalveinaccordancewithSection918.3.1.Stackvents

Page 24: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

24

andventstacksshallbepermittedtoterminatetostack-typeairadmittancevalvesin

accordancewithSection918.3.2.

918.3.1Horizontalbranches.

Individualandbranch-typeairadmittancevalvesshallventonlyfixturesthatareonthe

samefloorlevelandconnecttoahorizontalbranchdrain.Wherethehorizontalbranch

islocatedmorethanfourbranchintervalsfromthetopofthestack,thehorizontal

branchshallbeprovidedwithareliefventthatshallconnecttoaventstackorstack

vent,orextendoutdoorstotheopenair.Thereliefventshallconnecttothehorizontal

branchdrainbetweenthestackandthemostdownstreamfixturedrainconnectedto

thehorizontalbranchdrain.ThereliefventshallbesizedinaccordancewithSection

906.2andinstalledinaccordancewithSection905.Thereliefventshallbepermittedto

serveastheventforotherfixtures.

918.3.2Stack.

Stack-typeairadmittancevalvesshallbeprohibitedfromservingastheventterminal

forventstacksorstackventsthatservedrainagestackshavingmorethansixbranch

intervals.

918.4Location.

Individualandbranch-typeairadmittancevalvesshallbelocatedaminimumof4inches(102

mm)abovethehorizontalbranchdrainorfixturedrainbeingvented.Stack-typeairadmittance

valvesshallbelocatednotlessthan6inches(152mm)abovethefloodlevelrimofthehighest

fixturebeingvented.Theairadmittancevalveshallbelocatedwithinthemaximumdeveloped

lengthpermittedforthevent.Theairadmittancevalveshallbeinstallednotlessthan6inches

(152mm)aboveinsulationmaterials.

918.5Accessandventilation.

Accessshallbeprovidedtoallairadmittancevalves.Suchvalvesshallbeinstalledinalocation

thatallowsairtoenterthevalve.

918.6Size.

Theairadmittancevalveshallberatedinaccordancewiththestandardforthesizeofthevent

towhichthevalveisconnected.

Page 25: 2015 IPC Code Ch 8-9 (final) - All Star Training · 2017. 12. 6. · 2015 IPC CODE – CHAPTERS 8-9 SECTIONS 801-918.8 INDIRECT/SPECIAL WASTE Changes to the 2012 Code are highlighted

25

918.7Ventrequired.

Withineachplumbingsystem,notlessthanonestackventorventstackshallextendoutdoors

totheopenair.

918.8Prohibitedinstallations.

Airadmittancevalvesshallnotbeinstalledinnonneutralizedspecialwastesystemsas

describedinChapter8exceptwheresuchvalvesareincompliancewithASSE1049,are

constructedofmaterialsapprovedinaccordancewithSection702.5andaretestedfor

chemicalresistanceinaccordancewithASTMF1412.Airadmittancevalvesshallnotbelocated

inspacesutilizedassupplyorreturnairplenums.Airadmittancevalveswithoutanengineered

designshallnotbeutilizedtoventsumpsortanksofanytype.