2013 commercial brochurev2 - tarantin hot water solutions system intelligence 29.7” (h) x 19.1”...
TRANSCRIPT
COMMERCIALHOT WATERSOLUTIONS
SYSTEM INTELLIGENCE29.7” (H) x 19.1” (W) x 11.8” (Depth)
105 lbs.
Max. 380,000 Btuh- Min. 22,500 Btuh
Max. 380,000 Btuh- Min. 22,500 Btuh
0.7-13.2 Gal./min.
80% (NG), 84% (LP)
100-150˚F (in 5˚F Intervals), 160, 170, 180˚FRemote Control& Cord, Anchoring Screws
Thermal E�ciency
Temperature OutputsIncluded Accessories
Dimensions
Weight
NG
LPGas Consumption
Capacity Range
84%EFFICIENCY
NC380 ASME Series• max temp setting: 180˚• temp settings: 100-180˚• 0.7 min gpm- 13.2 max gpm• 534 GPH at 70˚ temperature rise • NSF & ASME certified• stainless steel casing• 2-unit quick-connect • up to 24-unit multi-system
Vent Options
SV
24.4” (H) x 18.4” (W) x 9.4” (Depth)
OD: 66 lbs. DV: 68 lbs.
Max. 199,900 Btuh- Min. 16,000 Btuh
Max. 199,900 Btuh- Min. 16,000 Btuh
0.5-11.1 Gal./min.
94%
Remote Control & Cord, Anchoring Screws,Drain Hose (DV Only)
Thermal E�ciency
Temperature Outputs
Included Accessories
Dimensions
Weight
NG
LPGas Consumption
Capacity Range
100-150˚F (in 5˚F Intervals), 160, 170, 185˚F
• max temp setting: 185˚• temp settings: 100-185˚ • 0.5 min gpm- 11.1 max gpm • 318 GPH at 70˚ temperature rise • stainless steel casing• 2-unit quick-connect • up to 24-unit multi-system
94%EFFICIENCY
Vent Options
NCC1991 Series
OD
SV CONVERSION
DV
Condensing
24.4” (H) x 18.4” (W) x 9.4” (Depth)62 lbs.
Max. 250,000 Btuh- Min. 11,000 Btuh
Max. 250,000 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
84%
100-150˚F (in 5˚F Intervals), 160, 170, 180˚F
Remote Control & Cord, Anchoring Screws
Thermal E�ciency
Temperature Outputs
Included Accessories
DimensionsWeight
NG
LPGas Consumption
Capacity Range
NC250 ASME Series• max temp setting: 180˚• temp settings: 100-180˚ • 0.5 min gpm- 11.1 max gpm • 360 GPH at 70˚ temperature rise• NSF & ASME certified• stainless steel casing • 2-unit quick-connect • up to 24-unit multi-system
84%EFFICIENCY
Vent Options
DVSV
DVC Unit: 23.6” (H) x 13.8” (W) x 10.2” (Depth)OD Unit: 23.6” (H) x 13.8” (W) x 9.4” (Depth)DVC Unit: 55 lbs. OD Unit: 47 lbs.
Max. 199,900 Btuh- Min. 16,000 Btuh
Max. 199,900 Btuh- Min. 16,000 Btuh
0.5-9.8 Gal./min.
84%
100-150˚F (in 5˚F Intervals),160, 170, 185˚F
Remote Control & Cord, Anchoring Screws
Thermal E�ciency
Temperature Outputs
Included Accessories
DimensionsWeight
NG
LP
NC1991-ODGas Consumption
Capacity Range
Max. 199,900 Btuh- Min. 16,000 Btuh
Max. 199,900 Btuh- Min. 16,000 Btuh
NG
LP
NC1991-DVCGas Consumption
NC1991 Series• max temp setting: 185˚• temp settings: 100-185˚ • 0.5 min gpm- 9.8 max gpm • 288 GPH at 70˚ temperature rise • 2- unit quick-connect• up to 6-unit multi-system
84%EFFICIENCY
Vent Options
ODDVC
PVCV E N T I N G
ZERO CLEARANCE
MODEL NUMBER
NC380 ASME SERIES GPHGPMGPHGPMGPHGPMGPHGPM
380,000380,000250,000250,000199,900199,900199,900199,900
NC250 ASME SERIES
NCC1991 SERIES
NC1991 SERIES
FLOW BTU INPUTTEMPERATURE RISE
79213.263010.55589.35048.4
40°75012.55048.44447.44026.7
50°62410.4420
73726.23365.6
60°5348.9360
63185.32884.8
70°4687.83185.32764.62524.2
80°4146.92824.72464.12223.7
90°3726.22524.22223.72043.4
100°3425.72283.82043.41833.05
110°3125.22103.51863.11682.8
120°2884.81923.21742.91562.6
130°
WWW.NORITZ.COM/COMMERCIAL LT0004
PLUMBING-HEATING-COOLINGCONTRACTORS ASSOCIATION
UTILIZE REDUNDANCYNoritz Commercial Tankless water heaters can be linked to create redundancy, even with a unit not in operation, hot water will be delivered.
COMMERCIAL ACCESSORIES
System Controller(SC-XX)
COMMERCIAL REMOTE CONTROLLERBuilding Management System(BMS1-SC-XX)
NORITZ COMMERCIAL TANKLESS ADVANTAGE
WWW.NORITZ.COM/COMMERCIAL
FACILITY:LAMBERT LAUNDROMATWHITTIER, CA31 WASHERSINSTALLATION:4 UNITS OF NCC1991-DV
FACILITY:UNIVERSITY DORMITORIES37-52 APTS, 4 BUILDINGSINSTALLATION:16 UNITS OF NCC199-SV WITH OUTDOOR CAP (VC-4C)
FACILITY:RESTAURANTSCOMMERCIAL KITCHENINSTALLATION:4 UNITS OF NCC1991-OD
LOWER ENERGY COSTSave up to 30% on Your utility bills.
LONGER LIFE SPANExtended lifespanup to 20 years.
NO WATER STORAGEReduce liability with Noritztankless. No water leaks that cause costly damage.
SMART MODULATIONAutomatically distributes water flow evenly between units, maximizing life of heaters.
ONLINE COMMERCIAL SIZINGSize any commercial applicationat www.noritz.com/commercial
EASY MAINTENANCEOur Support Team is dedicatedto assist your commercial jobs.
•Temp. adjustment from 100-185 (°C or °F)•Recirculation Control Feature•Time Stamps Error Codes
Commercial H2Flow WaterTreatment(CH2F-XXX)
Commercial Rack System(MR-2)