  • Page: 2 of 6

    REVISION LOG

    STV EXTENSION STV SOUTH

    WEST PROJECT (SVSW)

    EPCI FOR WHP-SVSW,

    PIPELINES AND CPP

    MODIFICATIONS

    DATASHEET FOR OPEN DRAIN HEATER

    Document No.: 2013-3262-3M-0001

    Revision: A

    Revision No. Section Revision Description

    A ALL ISSUED FOR REVIEW

  • 1 Mainufacturer: EX HEAT or Equal Area Classification: Class 1, DIV 2, Group D, T3

    2 Quantity: One

    3 Horizontal Vertical Fluid composition: HYDROCARBON LIQUID & WATER

    4 Specific Gravity of Contents: 0.8 - 0.975

    5 Code: ATEX Operating Pressure: ATM

    6 Specifications: 2013-3269-3L-0011 Operating Temperature C: 60C

    7 Bundle length mm; 750 ( VTC) Operating Liquid Level mm: 550

    8 Flange Diameter: 6" ( VTC) ( note 12) Normal Liquid Volume ( at NLL) m3: ( Note 14)

    9 Design Pressure barg: WATER FULL+ 0.05Barg

    10 Vacuum Design bar: - 0.002barg Flanges: SA105N

    11 Design Max. tempaerature C: VTA Baffles/ Tie Rods: 316SS

    12 Design Min. tempaerature C: 0 Elements: Alloy 800 Uns No8800

    13 Seismic Loads ( Horz./Vert.) g: N/A Gaskets 316SS Spiral Wound, 4.4 mm thk.

    14 Wind & Transportation Load: ( Note 2)

    15 Blast load bar: N/A 316SS inner & outer rings, graphite filler

    16 Slug Loads barg: N/A Bolts & Nuts: ( refer A1 Pipe Class)

    17 Corrosion Allowance (lnt.) mm: 3 mm PTFE COATED

    18 Terminal Box: 316L SS

    19 Heat Loss Duty (KW): 10KW Namplate: 316L SS

    20 Total Surface area m2: VTA

    21 Heat transfer coefficients W/m2.C: VTA Inspector Authority: VR

    22 Mean teamperature difference C: VTA Post Weld Heat treatment: N/A

    23 Radiography N/A

    24 No. Active: 3 DPT: YES

    25 No. Spare: 2 Ultrasonic: NO

    26 Diameter mm: VTA Hydrostatic Test barg: VTA

    27 Active "U" mm: VTA

    28 Total Load kW: 10 External Coating: Note 3

    29 No. of element per phase: VTA

    30 Element Load kW: VTA Heater Bundle Weight (kg): VTA

    31 Voltage V: Note-4

    32 Flux W/cm2: VTA Protection: NEMA 4X/7

    33 Sheath temp. C: VTA Paint: Marine

    34

    35

    36

    37

    38

    39

    NO. QTY SIZE TYPE ORIENTATION SERVICES REMARKSFACERATING

    Heater ConnectionN5 1 6" ( VTC) ANSI 150# RF WN

    DESIGN DATA

    HEAT TRANSFER DATA

    NOZZLE SCHEDULE (Refer Pipe Class A1)

    OPERATING CONDITIONS

    MATERIALS ( note-8)

    FABRICATION & INSPECTION

    PROTECTIVE COATING

    WEIGHTS

    JUNCTION BOX

    ELEMENT DETAILS

    DATA SHEET

    PROJECT NAME:

    STV EXTENSION PLAN- STV SOUTH WEST (SVSW)

    EPCI FOR WHP-SVSW, PIPELINES AND CPP MODIFICATIONS

    Item Tag No. : HAP - 6225

    Requisition No. : 2013-3200-1W-0003

    Document No. : 2013-3262-3M-0001

    Sheet No. : 3 of 6

    Service : OPEN DRAIN HEATER

    Rev. : A

  • 40

    41 Tag No.: TZT-6225-3 TZT-6225-4

    42 Service: Heater Flange Over Temp. Heater Element Over Temp. ( Hi/Hi)

    43 P&ID No.: 2013-3262-01-0015 2013-3262-01-0015

    44 Line No.: NA NA

    45 Line Size ( Wall Thickness, mm): NA NA

    46 Quantity 1 1

    47

    48 Measurement Type: 3 Wire RTD, 100Ohm at 0 Deg.C 3 Wire RTD, 100Ohm at 0 Deg.C

    49 Element Material: Platinum Element Platinum Element

    50 Instrument Connection Thread: NA NA

    51 Immersion Length: VTA VTA

    52 Thermowell Connection NA NA

    53

    54 Thermowell Material: NA NA

    55 Thermowell Immersion Leght: NA NA

    56 Thermowell Lagging Length: NA NA

    57 Thermowell Construction Style: NA NA

    58 Thermowell Process Connection: NA NA

    59 Thermowell Stem Style: NA NA

    60 Thermowell Mouting: NA NA

    61 Flange Type/ Rating/ Material: NA NA

    62

    63 Electronic/ Smart Hart Protocal: Yes/ Smart Hart Yes/ Smart Hart

    64 Output Signal: 4-20mA (24VDC) 4-20mA (24VDC)

    65 Power Supply: 24VDC ( Loop Powered) from ICSS 24VDC ( Loop Powered) from ICSS

    66 IP Rating/ Tropicalized: NEMA 4X NEMA 4X

    67 Electrical Protection: NEMA 7 NEMA 7

    68 Certificate Number;

    69 Hazardous Area Classification: Class I, Div. 2, Group D, T3 Class I, Div. 2, Group D, T3

    70 Electrical Connection: M20 x 1.5 M20 x 1.5

    71 Process Connection: NA NA

    72 Housing Material: SS316 SS316

    73 Housing Paint: Polyurethane Polyurethane

    74 Accuracy: +/- 0.03% of span +/- 0.03% of span

    75 Temperature effect: +/- 0.001% of span +/- 0.001% of span

    76 Range Min/ Range Max: VTA VTA

    77 Manufacturer: ROSEMOUNT or Equal ROSEMOUNT or Equal

    78

    SENSOR

    THERMOWELL

    TRANSMITTER

    GENERAL TRANSMITTERS TEMPERATURE

    DATA SHEET

    PROJECT NAME:

    STV EXTENSION PLAN- STV SOUTH WEST (SVSW)

    EPCI FOR WHP-SVSW, PIPELINES AND CPP MODIFICATIONS

    Item Tag No. : HAP - 6225

    Requisition No. : 2013-3200-1W-0003

    Document No. : 2013-3262-3M-0001

    Sheet No. : 4 of 6

    Service : OPEN DRAIN HEATER

    Rev. : A

  • 79

    80 Chemical / Material:

    81 Chemical Seal Diaphragm

    82 Bottom Flange Material:L

    83 Capillary Material / Lengh (m):

    84 Integrated Indicator: Yes ( LCD Display) Yes ( LCD Display)

    85 2" Pipe Mounting Bracket SS316L No No

    86 Manifold: No No

    87

    88 Fluid: HYDROCARBON LIQUID & WATER HYDROCARBON LIQUID & WATER

    89 Flow rate: Inlet / Outlet 0 0

    90 Design Pressure: Water Full + 0.05barg WF + 0.05barg

    91 Design Temperature: VTA VTA

    92

    93

    94

    95

    96

    97

    98

    99

    100

    101

    102

    103

    104

    105

    106

    107

    108

    109

    110

    111

    112

    113

    PROCESS DATA

    ACCESSORIES

    DATA SHEET

    PROJECT NAME:

    STV EXTENSION PLAN- STV SOUTH WEST (SVSW)

    EPCI FOR WHP-SVSW, PIPELINES AND CPP MODIFICATIONS

    Item Tag No. : HAP - 6225

    Requisition No. : 2013-3200-1W-0003

    Document No. : 2013-3262-3M-0001

    Sheet No. : 5 of 6

    Service : OPEN DRAIN HEATER

    Rev. : A

  • 114 NOTED:

    115 1) The immersed heater Tag no. HAP-6225 is to be mounted on Open Drain Tank Tag No. ABJ-6225

    116 2) The Heater with the tank shall be designed for wind load ( 3 second wind speed) and transportation load as detail in

    117 Specification for Atmospheric Tank: 2013-3200-11-0006

    118 3) Painting shall be in accordance with COMPANY specification 2012-3189-61-0010-3289-6L-0010 " Specification Painting and Protective Coating"

    119 4) The electric heater power supply shall be 3C 4mm XLE, 480V, 3 phase, 60Hz.

    120 5) VTA = VENDOR To Advise

    121 VTC = VENDOR To Confirm

    122 6) The Heater assembly shall be designed to avoid excessive vibration during operation. Necessary internal support inside the tank shall be provided

    123 ( by Tank Vendor). Heater Vendor to advise any such additional support required

    124 7) VENDOR to confirm material selection

    125 8) Heater shall be designed for full of liquid of Open Drain Tank ABJ-6225 (Tank height is 1.3m)

    126 The Liquid condition as follow: Fluid (Note 14 )

    127 Density 82-975

    128 Viscosity 13.3CP - 0.6737CP

    129 Wax Appearance Temp. 54C

    130

    131 9) VENDOR to advise, in their proposal, impact of mercury traces in the fluid on material selection

    132 10) Minimum design temerature to be minimum ambient air temperature. VENDOR shall calculate and confirm the minimum.

    133 Design metal temperature ( MDMT) for the proposed material and selected thickness with their proposal, talking into account all heater components.

    134 11) VENDOR to provide, heater termination box shall have space heater with rated 240 VAC but power by 120VAC.

    135 12) VENDOR to provide optional SIL-2 rated TZT's in accordance with IEC 61508

    136 13) Heater duty must be enough to heat up fluid from 20 C- 60 C at 550mm

    137 14) Open drain Tank is isulated to avoid heat loss. The thickness of insulation is refered on document 2013-3262-1M-0001_ Open Drain Tank Datasheet

    138 15) Process datasheet shall be refered in document 2013-3262-1M-0001_ Open Drain Tank Datasheet

    139 16) Insulation will be used for oil compartment

    140 17) Flange Shall be conform to ASME B16.5

    141 18) Vendor to provided local Stop Push Button.

    142 19) Vendor to provided permanently attached ss316ss tags of Transmitters, minium thickness of 1/16"

    143

    144

    145

    146

    147

    148

    149

    150

    151

    DATA SHEET

    PROJECT NAME:

    STV EXTENSION PLAN- STV SOUTH WEST (SVSW)

    EPCI FOR WHP-SVSW, PIPELINES AND CPP MODIFICATIONS

    Item Tag No. : HAP - 6225

    Requisition No. : 2013-3200-1W-0003

    Document No. : 2013-3262-3M-0001

    Sheet No. : 6 of 6

    Service : OPEN DRAIN HEATER

    Rev. : A

    Cover -1Cover -2Sheet 1Sheet 2Sheet 3Sheet 4