2012 georgia minimum residential prescriptive deck details_201401061514101938

Upload: dan-mihai-vasilache

Post on 05-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    1/22

     eorgi

    mendments

    Prescriptive Deck

     Details

    Based

     on the 2 12  nternational Residential

     Code

    This

     design document applies

     to

     single-span single-level residential decks only

    Decks must

     be

     constructed

     in

     conformance with

     the details

     contained herein.

      A

    copy

     of

     this

     deck

     detail must

     be on the job

     site

     and

     available

     to the

     inspector

    during

     each

     required inspection.

    Georgia

     Amendments

    Prescriptive  eck

     Details Sheet

     1 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    2/22

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    3/22

    G N R L  REQUIREMENTS

    1.  Lumber shal l  be natural ly  durable wood or  shal l  be southern pine,  grade  2  or better  that  is  pressure-

    preservative-treated

      in

     acco r dan ce

     with

      A W P A

      l  for the

      species, product,  preservative

      and end

      use.

    Field  cut  ends, notches and  dr i l led holes  o f  preservative treated w ood sh all  be treated  in the  field  in

    accordance with

      A W P A  M 4.

      Preservative-

      treated

      lumber

      in

      contact with

      th e

      ground shal l

      be

      rated

      as

      ground-contact.

    Please  note:  not all

     treated lumber

     is rated for  ground contact.

    2.  W ood-p las t i c compos i tes  are  composed o f  bound wood  and  plast ic f ibers creating

      mater ia l

     that

     can be

    used

     as decking and guard elements as

     permitted

     herein.  Permissible wood-plastic composites must

    bear a labe l indicat ing i ts perform ance

      criteria

      and compl iance

     with  ASTM

      D 7032 .

    3. Nai ls sha ll be r ing-shanked or annu lar groo ved .

    4.  Screws and  nai ls shal l  be  hot-dipped galvanized, stainless steel  or app r oved  for use

     with

      pressure

    treated lumber.

    5.

      Hardware ,

     e.g., joist  hangers, cas t - in-p lace post anchors, m echanical fasteners, shal l

      be

      galvanized

    with  1.85 oz/sf  o f zinc  (G-185  coating)  or  sha l l be stainless steel.  Use products such  as  Zmax from

    Simpson  Strong-Tie  or  Triple

     Zinc

    and Gold  Coat from  USP.

    6.

      Electrical

     receptacles

     for

      decks

      shall

     comply

     with

     the

     currently

     approved

     edition

     of the National

    Electr ical Code.

    7.

      Lighting

      fo r  decks  and

     exterior

      sta i rs sh al l comply with  IR C 303 .7 S ta i rway  Illumination.

    8. Decks constructed   in acco r dan ce

     with

      these detai ls  are not  app r oved for  pr ivacy screens,

     planters,

    built-in

     seating or hot tub installations.

    DECKING

     pprove Material

    W o o d

      and

      wood-plast ic composi te decking shal l

     b e

    installed

     in

      accordance with

     the

      requirements  below.

      Dimensions shal l

      be 2x6 or

      5

    /4

      ( five-

    quarter )  fo r  w o o d and per m anufactu re r  fo r

    wood-p las ti c com pos i tes .

    • W ood decking m ay be p laced at an angle of

    45

      to 90

      degrees

      to the joists.

    •  At tach woo d decking  in acco r dan ce

     with

    FIGURE

     1.

    Placement

      and

     at tachment

      o f

      wood-plast ic

    composi tes sh al l be per

     manufacturer's

    instructions.

    wood 2x6 or 5/.

    ( five quarter )

    board

    (2)8d  nails

     or

     (2)#3

    screws at each joist

    FIGURE 1: TYPICAL DECKING

    • W ood -plast ic compo si te label  and  manufacturer 's

      instructions

     must  be  left  on the jobsite  fo r

    inspector verification.

    Plastic

      Deck/no

    Plastic  or PVC decking,  not considered a wood -plas t ic comp osi te, may be substi tuted  only  when the

    product

     has a

     valid evaluation report from

     an accredited

     listing  agency

     and is

     capable

     of

     resisting

     a

     live

    load of 40  PSF.

      Installation

      shall  be in  con fo rmance to the  evaluation

      report

     and the  manufacturer 's

    installation  instructions  which  must be ava i lab le to the  inspector .  -

    Georgia Amendments Prescriptive Deck Details

    Sheet 3 of

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    4/22

     O STS

    Jo is ts

      s h a d  be des igned in acco r dance with  the requi rements below.

    •  Joist

      s p a n

      is  measured between  th e  center l ine  o f  bear ing  a t  each end o f the joist a nd  does  no t

    inc lude   th e  over hangs .

    • See FIGURE 2

     through

      FIGURE 4 for joist span

      types.

    • U se TABLE 1 to  de ter mine your joist  s ize  b a s e d o n s p a n

     length

      a nd  sp a c ing .

    • The

     maximum

      over hang  is eq u a l  to

     one-fourth

      of the  length  of the joist  span (0 .25  x joist  s p a n ) .

    •  At tach  rim joist  to end of joists  a s s h o w n  in  FIGURE 2 and  FIGURE 4 .

    joist to

      ends

    of

     each

     joist

    with  (3) #10

    x 3 w o o d

    screws

      or (3)

    10d  nails

      optional overhang  existing

      house wa l l

      —

    A1- — rim joist

    beam

      »-

     

    overhang 1

    1

    joist

     hanger- —

     *-J

    Voist

      ledger board

     —

    -*

     —

     pos t

      _̂̂ -

    L_ 

    joist

      span

    \

    FIGURE 2: JOIST SPAN WIT OVERHANG  DECK ATTACHED AT HOUSE

    existing

     house

     wa l l -

    beam

    post—*

    beyond

    FIGURE 3: JOIST SPAN  JOISTS ATTACHED TO SIDE OF BEAM

    2x blocking between joists; attach —

     

    with

     (3)

     10d

     toe

     nails each side

      \r

    ^r

      - r —

    . „ „

    ,  . . .  ,

    to

     ends

     of

     each

    #10 x 3 wood

    screws or (3)

    10d nails

    __J—_

     J*,-.

    \K

    7f^»

     — rim

     joist

    beam-

      »-

    optional

    \ —

    -̂joist

    — •

    — post

     

    joist

     span

     

    -^

    i

    n

     —

    pos1_____

    optional

    ' overhang1 

    overhang1

    --,

    y

     

    -^—  existing

    house

    wall

    FIGURE

     4:

      JOIST

     SPAN - FREE-STANDING  DECK2

    1

    The

     maximum  length

     of the overhang  is

     equal

     to

     one-fourth

     of the

     joist

     span

     length (0.25

     x

     joist

     span).

    2 For more  information on Free-standing  Decks see Sheet 14.

    Georgia  Amendments Prescriptive  eck

      etails

    Sheet 4 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    5/22

    TABLE 1;  MAXIMUM JOIST

      SPAN LENGTH1

     oisjs without Overhangs  oists with  Overhangs

    Joist Spacing-^

    Joist Size4-

    2x8

    2x10

    2x12

    12

    13'-8

    17'-5

    18'-0

    16

    12'-5

    15'-10

    18'-0

    24

    10'-2

    13T-1

    15'-5

    Joist Spacing-^

    Joist Size4

    2x8

    2x10

    2x12

    12

    10'-6

    15'-2

    18'-0

    16

    i t r 6

    15'-2

    IS'-O

    24

    10'-2

    13--1

    15'-5

    Spans

     are

     based

     on 40 PSF

     live  load,

     10

     PSF dead  load, southern pine

      2,  normal

      loading duration,

      we t

     service cond itions

    an d deflections o f

     A=£ /360

     for  main

      span

      an d £/180 for

      overhang.

    BEAMS

    Beams

     shall

     be designed and  assembled   in

     accordance

     with the  requirements

     below.

    • As shown in FIGURE 5,

     beam

     span is measured between the centerlines  of two adjacent posts.

    •  Beam size   is

     determined

     using TABLE 2.

      Beams

     may   overhang

     each

     end up to  one-fourth of the  beam

     span

      (0.25 x

     beam

     span)  as shown in

    FIGURE

     5.

    •  Using the members  identified  in  TABLE 2, beams

     shall

     be assembled  in  accordance with  FIGURE 6.

      Beam splices shall  be located over

     interior

     post locations

     only.

    joists above

      ~

    VI

     

    optional

    ^beam

     -̂   —post, typical

    beam span

     

    V

     

    IA

    M

    ^—   beam splices at interior

    post locations only

    beam span

    optional

    FIGURE 5:

     BEAM

     SPAN TYPES

     

    Th e maximum length of the overhang is equal to one-fourth o f the  beam span  length

     (0.25

     x  beam span) .

    TABLE

     2:

     MAXIMUM  BEAM SPAN LENGTH 

    Beam Size-̂

    Joist Span 1̂

    <

     6'

    >  6' -

     8'

    >

     8'

     -

     10'

     

    10' -

     12'

    > 12' - 14'

      14'

     - 16'

      16'

     -

     18'

    (2)2x6

    7'-l

    6 T  2

    5

    T

     6

    5'-0

    4r-8

    4'-4

    4'-l

    (2)2x8

    9'-2

    7'-ll

    7'-l

    6

    r

    -6

    6'-0

    5'-7

    5'-3

    (2)2x10

    ll'-lO

    10'-3

    9'-2

    8'-5

    7'-9

    7'-3

    6'-10

    (2)2x12

    13'-11

    12'-0

    10'-9

    9'-10

    9'-l

    8'-6

    8'-0

    (3)2x6

    8'-7

    7'-8

    6'-ll

    6'-3

    5'-10

    5'-5

    5'-2

    (3)2x8

    ll'-4

    9'-ll

    8'-ll

    8'-l

    7'-6

    7'-0

    6'-7

    (3)2x10

    14'-5

    12'-10

    ll'-6

    10'-6

    9'-9

    9'-l

    8'-7

    (3)2x12

    17'-5

    15'-1

    13'-6

    12'-4

    ll'-5

    10'-8

    lO'-l

    Spans are

     based

     on 40 PSF live

     load,

     10 P SF dead  load, southern pine 2,  normal load ing duration, w et service conditions

    and   deflections  of A=£ /360  for  main

     span

     an d

     t/180

      for  overhang with  a 230

      Ib .

      point  load.

    Georg ia

     Amendmen t s

    Prescriptive Deck

     Details

    Sheet 5 of

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    6/22

    If a beam is constructed with 3-plies, attach each •

    outside member to the  inside as  shown herein

    1Q d

     common

      nail

      or

    #10 w ood screw,

    staggered

     in 2

     rows

    2  common nails or screws at each

    end and at

     splice ends

    Note: splices are permitted  in multi-span beams over interior post locations only.

    FIGURE :

     BEAM ASSEMBLY

     DETAIL

    DECK  PLAN

    Length  to Width Ratio

    For decks  attached  to the  existing house only/  th e  rat io  of the  overall deck length, L, to the  overall deck

    width/ W,  must  be no  more than  2 to 1 as s hown  in  FIGURE 7.  This requirement  ca n also  be verif ied  by

    ensuring  L ~ W 

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    7/22

    JOIST TO BEAM CONNECTION

    Each joist  sha l l  be  a t tached   to the  beam   a s s h o w n   in   FIGURE  8. Use  Option   1 or  Option   2 w h e n joists

    bear on or overhan g pa st the beam as shown in FIGURE 2 and FIGURE 4. Use Opt ion 3 when

     joists

      at tach

    to the   s ide of the  beam   a s show n   in   FIGURE  3 ;  however,  th e

     joist

      depth

      must

      be

      less

      t han   or  e q u a l  in

    depth

      to the

      beam depth .

      See

      oist

     Hangers

      be low

     f or information  on

      ha nger requ irements . Mec ha n ica l

    fasteners

      or

      hurr icane c l ips used

     in

      Option

      2

     sha l l have

     a minimum

      capac i t y

      of 100

      Ibs.

      in both

     uplift

      and

    lateral load direct ions.

      See ma nufac turer 's

      instructions

      fo r

     minimum

      insta l lat ion

     requirements.

    OPTION 1* OPTION 2

      O PT IO N S

    (3) 8d toe

     naile

    (2 on one

      side

    1 on the

      other

    c:

    V y

    mechanical  —  

    fastener

     or  \e clip

      \

      V

    bea

    \  . .  | —  top of

     beam

     and

     Joist

    V

      j oi s t— ,  must

     be at

     same

    21

    hanger elevation

    £-\

    n

     

    /i=X

      j

    *0ption 1 is prohibited on free-standing  decks

    >

    FIGURE 8: JOIST-TO-BEAM DETAIL

    JOIST HANGERS

    Joist  hangers , a s sh own in FIGURE 9,  sha l l  h ave a minimum

    capac i t y

      of 600

      Ibs.

      fo r

      2x8s,

      700

      Ibs.

      fo r 2xlOs  and 800

      Ibs.

    fo r 2xl2s.  Th e

     joist

     h anger sha l l be designed   a nd

    manu f ac tu red for the  number  of  plies it is  carry ing.

    Use

     joist

     hangers with

     inside

     flanges when  c learances

      to the

    edge

      of the  beam   or  ledger board dictate,

    Do

     not use

     clip

     angles

     or brackets to

     support framing

    members.  Do not bend hanger flanges to  accommodate

    field conditions.

    POSTS

    Deck   posts sha l l

      be 6x6

     with

      a maximum

      height

      of

     14'-0 measured

    from the top of the  footing to the  underside of the  b e a m .  The beam

    sha l l  be

     a t t ached

      to the

      post

      by one of the

      methods shown

      in

     FIGURE

    11. The attachment  condi t ion shown in  FIGURE  10 is prohibited.

    The   post  cap  show n   in   FIGURE  11 ,  Option   2

     sha l l

      be  specif ical ly

    designed for  tw o -  or  three-ply bea ms   and 6x6  posts

     with

      a minimum

    d o w n w a r d  a l low ab le load capac i ty

      of 5,000

      Ibs . A ttachment sha l l

     be

    per

      m anu fac tu rer 's instructions.  Post  caps  sha l l

      be

     ga lvan i zed

      per the

    requirements noted   on   Sheet  3. 4x4 & 4x6   posts  can be used   if

    tributary  loading values are calcu lated by a design professional .

    Cut

     ends of

     posts

     shall be field

     treated

     with a wood

    preservative containing

     copper

     naphthenate in accordance

    with AWPA M4.  Such products can be found in the paint

    department of most hardware or home

     center stores.

    Georgia Amendments Prescriptive

     Deck Details

    joist  hanger with inside flangesy

    FIGURE

     9: TYPICAL JOIST

     HANGERS

    FIGURE

     1 :

     PROHIBITED

    POST TO BEAM ATTACHMENT

    Sheet 7 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    8/22

    2-ply beams

    only

    beam must bear

    on 6x6 notch

    6x6 post

    post cap; attachment,

    fasteners   pe r  manu-

    facturer s instructions

    (2) 2

    diameter

    through-bolts

    with washers

     3-pIy  beams

     must

    use post cap

    option

    OPTION 1

    notch p ost to

    provide beam

    with flush  and

    tight  bearing

    6x6

     post

    OPTION  2

    FIGURE

      :

     POST TO BEAM

     CONNECTION OPTIONS

    FOOTINGS

    Footings shall

      be

     constructed

      in

      accordance with

      th e

      requirements

      below.

      Concrete shall

      be

     air-entrained

      and

      have

     a

     minimum com pressive strength

      of

      3,000 PSI.

    •  Footing size and  thickness

      shal l

      be in  accordance with  TABLE 3.

    • See FIGURE 12 for post attachm ent options and requiremen ts.

      Post ancho rs

      shall  be

     galvanized

     per the

      requirements noted

     on

     Sheet

     3.

      Footings shal l  bear

     on

     sol id ground; bearing condit ions must

      be

     verified

      by

      county inspectors prior

    to

      p lacement

     o f

     concrete.

      Bottom

     of

     footing should

      be at least 12

      inches below grade.

      Deck

     footings   c loser

      than  5T - 0

    to an

     existing

     exterior  house

     wall

     must  bear  at the   same

    elevation

     as the

     existing  house  footings,

    • Do not

     construct

     footings over

     u l ty

    lines or service pipe

    Call

     811 before you dig

    TABLE

     3:

     FOOTING

     SIZE

    B e a m   S p a n

    <

      8'

    >  8' - 12'

    > 12

    r -

     17'

    Joist  Span

    10' - 14'

    >14' - 18'

    <

      10'

    >10'

     - 14

    Size

     of

    Square

    15

    18

    21

    19

    22

    26

    23

    28

    Size

     of

    Round

    17

    20

    23

    21

    24

    28

    25

    30

    M i n i m u m

    Thickness

    1

    6

    8

    9

    8

    10

    11

    10

    12

    1The  cast- in-place

     post base

     m ay

      require

      a

     footing  thickness  greater than

      the

     va lue

      in the

     table

    above.  In such cases, the  manufacturer's specified  minimum   footing

     thickness

      shall govern.

    G eorg ia Amendments Prescriptive

     Deck

     Details

    Sheet

     S of

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    9/22

    Notes:

    1. post must be centered on footing

    2.  footings must bear on solid ground

    y—  pre-manufactured

     post

     base

    //  with cast-in-place anchor

    pe r Table 3

    -E

     ^

    -E

    12 diameter

    concrete stem

    per Table 3

    roughen

    concrete

    joint

    FIGURE

      2:

     TYPICAL FOOTING OPTIONS

    LE GER ATTACHMENTS

    Ledger boards shal l

      be

     attached

      to the

      existing

      house

      in

      accordance

     with

      th e

      requirements below.

      The

     depth

      of a ledger

      bo ard sha l l

      be

      greater than

      or

      equal

      to the

      depth

      of the joists.

    • The  at tachment  shal l  be in  acco r dance with  FIGURE  14.

    • The  band board of the  exist ing structure  shal l  be capab le  o f  suppor t ing  the new deck .  If  this

    canno t

      be verified  o r

     cond i t ions

      at the

      exist ing house

     differ from  th e  detai ls herein, then  a free-

    s tand ing deck

      is

      required.

      See

     Free Standing  Decks

      on

     Sheet

      14.

    •  Compliance

     with

     all

     the requirements herein is critical to

     ensure

     the

     safety

     and structura

    stability of your deck.

    Siding

      an d  Flashing

    Flashing shal l be instal led  in  accordance with  th e  requirements below.

    •  The exterior finish

    i.e.

    house siding must be removed prior to the installation of the

    ledger board.

    • Con tinuous f lashing

      with  a

     drip  edge,

      as

     s h o w n

      in

      FIGURE

     14,  is

      required

      at the

      ledger board when

    connected

      to a

     wood band board.

      Flashing

      shal l  be

     composed

     o f

      copper (attached using copper nails

     only ,

     sta in less steel,

     U V

    resistant  plastic  o r ga l van i zed steel  coated with

     1.85

     oz/sf  o f z inc

      (G-185

      coa t ing) .

    •  F lashing a t a  door threshold shall  be insta l led so as to prevent w a te r  intrusion from rain  or  melting

    i ce and snow.

    Wood

     I Joists

    Many  homes  constructed with  w o o d

     I-joists,

      as show n  in  FIGURE 13 ,  have a

    1 or

     thicker

      engineered wood product

      (EWP)

      band board capab le

     of

    support ing   a  deck;  se e  FIGURE  14. If a minimum  1 EW P or 2x  band board

    is

      not  present, then  a f ree-standing deck  is  required.  See Free Standing

    Decks  on Sheet  14 for  more

      information.

    FIGURE 13:

     WOOD

    I-JOIST PROFILE

    Georg ia

     Amendm en t s

    Prescriptive eck etails Sheet 9 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    10/22

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    11/22

    PROHIBITED LEDGER

     ATTACHMENTS

    The

     ledger board attachment conditions shown

    FIGURE

      17 through

      FIGURE

      19

      below

      are strictly prohibited. In such

      cases

     the deck shall be

     free-

    standing.

      See

      FREE-STANDING  DECKS

      on

      Sheet

      14.

    FIGURE

     IS: BRICK VENEER

    brick

    veneer or

    masonry

    chimne

    FIGURE

      7:

      FLOOR TRUSSES

    FIGURE  9:

     HOUSE

     OVERHANG

    LEDGER BOARD FASTENERS

    Ledger board fasteners

      sha l l

      be

     installed

     in

      acco rdance with

      FIGURE

     20 and the on

     center spacing

     in

    TABLE  4. Only those fastener types noted herein are approved for use.  A d e q u a c y of connections will be

    verified by county inspectors.

    2

    min. sides, top —

    & bottom edges

    4

     fasteners, each

    end of ledger board

    ©- (

    typical

    spacing

    NO LEAD ANCHORS

    2

    interior fasteners;

    2

     rows

     staggered

    1

    62 min.

      for 2x8

     

    6 - 2   min. for

      2x10

     

    min. for  2x12

    2

    FIGURE 20:  LEDGER BOARD

     FASTENER

     SPACING AND  CLEARANCES

    Addi t iona l  interior  fasteners are required at chimney or bay window; see FIGURE  2 1.

    TABLE

     4:

     EDGER

     BOARD

     FASTENER

     SPACING ON

     CENTER

    Fastener* *

    Through  Bolts

    Joist

     Span-D-

    Band

     Board* '

    EW P

    1

    2x lum ber

    S6'

    24"

    36

    >6'-8'

    18"

    36"

    >8'-10'

    14"

    34"

    >10'-12'

    12"

    29"

    >12'-14'

    10"

    24"

    >14'-16'

    9"

    21"

    >16'-18'

    8"

    19"

      EW P - 1 minimum m anufac tured engineered wood product; see Sheet 9 for more nformation.

    Throuah-Bolts

    Through-bolts shall have a minimum diameter of

     1

    /

    2

     .  Pilot holes  for through-bolts shall be  17

    /32

    to

     Vie

    in

     diameter. Through-bolts must be equipped

     with

     washers at the bolt-head and nut.

    Georg ia

      Amendments Prescriptive Deck Details Sheet 11 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    12/22

    FRAMING

     AT

     CHIMNEY

     OR BAY

     WINDOW

    All  f raming  at a ch imney  or bay sha l l  be constructed  in acco r dance with  FIGURE 21 and the

      requirements

    below.

      Header  size shall be equal to the joist size.

    •  W h e n  th e  chimney  or bay w indo w  is  deeper than 3'-0 , install  a 6x6  post

     with

     footing  per the

    requirements  on Shee t 8 below each triple joist  at the  location  of the  header connect ion.

      When

      th e

      header

      is

     longer than

     6'-0 ,

      install

      6x6

      posts

     with footing  per  th e requirements  on

      Sheet

    8

      below

      th e

      header

      to

      reduce

      th e

      s pan

     to

      less than

      6 '-0 .

    •  Post

     footings

      must meet  th e  requirements  on Sheet  8.

    •  Joist hang ers shall  be specif ical ly designed  to  a c c o m m o d a t e th e  number  of mem bers  identified  in

    FIGURE  21,

    3-ply

    1

    ]oistr

    each side

    6-0 maximum

    chimney

     o r

    bay  window

    E

     

    ledger

    board

    chimney

    or bay

    window

    decking may

    extend 6 maximum

    /—3-pIy

    1

     oist

    -ledger

    board

    -2-ply

     header

    PLAN VIEW

     2

     ledger board interior

    fasteners on each side of

    chimney or bay window2

    S T I O N

    Note:

     joist

     hange rs shall be

     sized

     for the number of plies supported

    FIGURE 2 : REQUIREMENTS FOR FRAMING AT CHIMNEY OR BAY WINDOW

    1May be

     reduced

     to

     2-ply

     joists if joist spacing = 24 on

     center,

     joist span 

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    13/22

    KNEE

      BRACING

    place knee bracing

     at all

     beam post

    locations

    K BRACING

    place k bracing in two adjacent bays

    k bracing

      is

     prohibited

     in

     single

     bay  decks

    X-BRACING

    place x bracing  in

     alternating

     bays

    FIGURE 22: DIAGONAL BRACING AT BEAM-POST LOCATIONS

     all decks

    provide

     blocking  behind

     joist

    to align connection

    KNEE

     BRACING

     

    place knee bracing at all

     joist-post

    locations

     

    align oists  to

     accommodate

     bracing

    connection  at post

      k-bracing shall be

      attached

      at the

    midspan

      of

     the

     joist

      align

     oists  to accommodate bracing

    connection  at post

    align joists to

     accommodate

     bracing

    connection

      at

     post

    FIGURE 23: DIAGONAL BRACING AT JOISTS-POST LOCATIONS

     free standing decks only)

    bracing back of  post

     

    2

    diameter through-

     bolt

    /  with

     washer typical

    -bracing front of post— 1

      ^bracing,

     back  of  post

    AT

     BOTTOM

     OF

     POST

      AT

     POST BEAM CONNECTION

      AT

     JOIST

     OR

     BEAM

    FIGURE 24: TYPICAL CONNECTIONS OF DIAGONAL

      MEMBERS

    G eorg ia Amendments Prescriptive

      eck

     Details Sheet 13 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    14/22

    FREE STANDING  DECKS

    Decks

      which are free-standing do not ut i l ize the exterior

      wa l l

      of the ex ist ing house to supp ort vert ical

    loads.

      Instead/

      an

      addit ional beam

     with

      posts is provided at or offset from the exist ing house; see

    FIGURE

     4.

      When

     the

      edge

     of the

      deck foot ings

      are

      closer than

     5'-0 to an

     exist ing exter ior h ouse wall,

      it

    must be ar at the sam e elevat ion as the e xist ing house footings, see FIGURE 25 below. Beam size is

    determined by TABLE 2.

    joist

      overhang

    «—existing house

    foundation wall

    diagional

    bracing

    <

     5'-0 ,

      footings must be

    at same

     elevation

     as

    existing house footing

    FIGURE 25:  FREE-STANDING  DECK

    GU RDS

    Guards/

      whether required  or not/  shal l  be  constructed  in  accordance

    with  the requirements on the procee ding pages and f igures.

    Deviations

     are

     prohibited.

    When

      Required

    When  a deck is greater than 30 above grad e at a point 36 from  th e

    edge

     of the

      deck,

      as

     s h o w n

     in

      FIGURE

     26/  a

     guard

      is

      required.

    W ood Plastic

      Composites

    Wood-plast ic c omposi tes of the sam e dimensions and comply ing

     with

    the cr i ter ia noted on Sheet 3 may be subst i tuted  for  the guard rai l-

    cap

     and

     infill  e lements

     show n in FIGURE 27 provided the

    manufacturer 's

      pe rformance cr i ter ia sp ec if ical ly al low it.

    edge of  deck

    deckfloor-i

    36

    grade

     elevation p

     

    CO

    A

    r

    *\E  2

    GUARD

     IS  REQUIRED

    Guard  Systems

    Pre-fabr icated systems com posed  of w ood , wood -plast ic composi tes  or  plast ic purchased from  a  home

    center

      store,

      lumber com pan y or s imi lar

     will

      require a plan submission during the

     permit

      appl icat ion

    process.

      Only guard systems

     with  a

     val id evaluat ion

     report from  an

      accredi ted

     listing

     a gency

     will be

    approved   for instal lat ion.

    Georgia Amendments

    Prescriptive

     Deck

     Details Sheet 14 of

     2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    15/22

    4x 4

      post,

     typical

     —

    DO

     NOT

     NOTCH  \

    I

    36

    minimum

    >

    i-

     ̂

    T

    i

    ^

    «  fi

    r™

    r  m

    '-0

    maximum spacing

      cap: 2x6,  5/4  board c

    anufactured

     material

    r approved

    /—

     2x2 pickets; may be placed on

    / either side

     of

     guard

     

    ©

     

    (2) 5 diameter  —

    through-bolts and

    washers

    2

    4

     

    I

     

    f

    ^

    )

     ̂O

     

    T

    v \

      \\

    ©

    ©

     

    N_ openings shall

     not

     allow

     the

    passage

     of a 4

    diameter

    sphere; wet lumber must be

    spaced such that when

    shrinkage occurs,

     the

     maximum

    opening is maintained

    V

    >

    u

    9

     

    2x4 top and

     bottom;

     

    may be

     placed

     on

    / either side of guard

    post; attach

     to

     post

    nails or (2) #8 wood

    screws

    attach pickets at top and

    bottom with

      (1 } #8

     wood screw

    or (2) 8d ring-shank nails with a

    0.135 nominal diameter

    FIGURE 7: TYPICAL

     GUARD

     DETAIL

    do   not  notch

    guard post

     a t

    deck

     connection

    FIGURE

      8: NOTCHING

    AT GUARD

     POSTS

    <

    centerline o f —

    guard post ~

    ^3   through-bolts

     and

     \s \l

     

    ^

    \

    f*i

    ^

     

    P

     

    cf   •

     £

     ĉ  

    \-outsidejoist

    or

      rim joist

     2

    minimum

    X

     

    <

     

    2 minimur

    ?

    n

    FIGURE 9:  GUARD POST ATTACHMENT DETAIL

    GUARD POST ATTACHMENTS

    Guard posts  must be a t tached  in  accordance with the  requ irements be low.

      Guard posts must

      be

     fastened

      to the

      f raming

      in

     order

      to

      ensure

      th e

     entire gua rd

      can

     resist

    imposed loads.

      Hold-d ow n anchors,

      as

     s h o wn

      in

      FIGURE

      3 0 a nd

      FIGURE

      3 1,

      shal l

      be

      used

      to

     attach

     the

      guard post

    to the  outside

     joist

     and rim

     joist,

      respectively.

    •  Ho ld-do wn anchors sha l l have  an

     1,800  Ib . minimum

     capaci ty  and  shal l  be  ga lvan ized  per the

    requirements   on  Sheet  3 .

      Gua rd posts

      m a y b e

     a t tached

      to

     either side

      of the r im

     joist

      o r

      outside  joist.

    Georgia

      Amendments Prescriptive Deck Details

    Sheet 15 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    16/22

    guard-

    post

    at first interior bay, provide 2x

    blocking at guard posts; toe nail with

    10d

     nails

     top and

     bottom, each side

    hold-down

    anchor, typical

    outside-joist

    guard

     post

    outside-joist

    fasteners

     and

    attachment per

    hold-down

    manufacturer

    blocking

    PLAN VIEW

    FIGURE 30:

      GUARD POST TO OUTSIDE

     JOIST DETAIL

    guard post

    hold-down

     anchor

    hold-down anchor

    joists

    align guard

    post

     at

     joist

    locations

    fasteners and

    attachment per

      i

     

    hold-down 

    manufacturer

    joist

    rim joist-

    guard post

    -rim  joist

    SECTION

    «—rim o is t

    hold-down anchor

    at  o ist

     location between   j o s t s

    PLAN VIEWS

    FIGURE 31: GUARD POST TO RIM JOIST DETAIL

    STAIRS

    Stair  Geometry

    Stairs

     shall be a

     minimum

     of 36 in

     width

     as shown in

    FIGURE   39.  Tread,

      r i s e r

      an d

     n o s i n g

      d i m e n s i o n s o p e n i n g  limitations  a n d

     t o l e r a n c e

      rninimums

      s h a ll

     meet

    th e   requirements s h o w n   in   FIGURE   32.

    Tread

     

    Riser

      aterial

    T read an d

     riser material

     s h a l l

      b e in

      a c c o r d a n c e

     with

      t h e

      requirements

     b e l o w .

    «   Tread material s h a ll  b e  equivalent to   d e c k i n g   as  specified o n

      S h e e t

      3.

    •  W o o d - p la s t ic c o m p o s i t e s   m a y n o t   h a ve

      c a p a c i t y

      fo r

     stair  t r e a d s

      e q u a l  t o

     their  w o o d equivalents.

    •  Tread material s h a l l  b e at ta c h e d p e r   FIGURE   35.

      R i se rs

     may be framed with

      x  lu m b e r

     minimum or equivalent wood-plastic composite.

    Georgia Amendments Prescriptive Deck

     Details

    Sheet  6 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    17/22

    riser

     may be open, but shall not

    allow the passage of a 4 diameter

    sphere

    7

     3/4

    ma>dmum

     riser;

     height

    shall

     n ot deviate from  one x

     

    CO

    stair landing  required  o

    per R31

     1.7.6

      \

    '

    -»•

    i

      ~~-̂ 3—

     c=r~^

    ^=— =cr

     

    —  —3/4 -

     

    ~  nosing

     shall not

     deviate from

    one another by m ore than 3/8

    V'' -^- Vv''--a:-^V-. - i .-.- <

      -

      -J

    FIGURE

     32:

     TREAD

     AND

     RISER DETAIL

    Stair  Stringers

    Stringers shall be constructed in accordance with  the following requirements.

    • Stringers shall be continuous  sawn or solid

     2xl2s

     meeting the stair  geometry  requirements  shown

    in FIGURE 32.

    •  Attach stringers

      to the

      deck

     per

     FIGURE

     34 .

    • Stringers shall be

     spaced

      at a maximum of 18 on center.

    •  Measured  horizontally, th e  maximum horizontal stringer  spans  shall  not exceed the lengths shown

    in

      FIGURE

     33.

    • Stringers with

      spans

      greater than maximum

      a l lowed

      shal l  be supported w ith 4x4 posts along their

    length to create mult iple compliant spans. The 4x4 post shall  be notched and bolted to the stringe

    with

      (2 )

      V z

    diameter through-bolts

      with

     washers

     per

      FIGURE

     11,

      Option

      1. The

     post shall

     b e

    centered on a 10 diameter or 8 square/  4 thick footing 12 below  grade  and be attached per

    FIGURE  12.

    •  Intermediate

      landings

     may

     also

      be

     provided

     to

      shorten

      th e

     stringer span ;

     s ee

     Stair Landings

      on

    Sheet  18 .

    maximum

     unsupported span = T 0

    maximum

     unsupported span

      = 16,-S

    SAWN STRINGER

    SOLID STRINGER

    FIGURE

      33:

     ST IR STRINGER REQUIREMENTS

    Georgia

     Amendments

    Prescriptive eck Details

    Sheet

      7 of 2

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    18/22

    solid, single rim

    joist or outside

    joist

    sloped

     joist

     hanger; see

    Joist

      angers for

     more

    requirements

    FIGURE

     34:

     ST IR

     STRINGER ATTACHMENT

     DETAIL

    attach tread material with (2)#8 screws or (2)

    8d

     nails per board at each stringer or ledger

    tread tread

    stringer

    18-MAX

    18 MAX.

    CUT STRINGER

    2x4 ledger, each side,  full

    depth o f  tread; attach with

    (4) 10d nails or (4)#8 scree ws

    SOLID STRINGER

    FIGURE 35: TREAD CONNECTION REQUIREMENTS

    Stair

      andings

    A floor or  landing will be required at the top and bottom of each stairway  per IRC Section R311.7.6.  If th

    total

      vertical height

      of a

     sta irway

     exceeds

     12'-0

    /

      then

      an

     intermediate

      landing

      will

      be

      required.

    Intermediate stair  landings shal l

      be

     designed

     and

     constructed

     as a

     free-standing deck  using

     the

      details

    herein.

      Howe ver, for

      stair landings

     only, 4x4

      posts

     may be

     used

      in

      lieu

     of 6x6  posts  fo r

      heights

      less

      than

    or

      equal

      to

      7 ' -0 .  Every landin g

     shall

      have

     a

      minimum dimension

     of 36 measured  in the

      direction

      of

    travel

      and not

      less  than

      th e

      width

      of the

      stairways served .

    Georgia

     Am endmen ts

    Prescriptive eck etails

    Sheet

     IS

     of

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    19/22

    6 - 0 m a x i m u m

    st ir gu rd is required for

    st irs with

     a

     tot l

     rise

     more

    th n

     30 at a

     point

     36

    from

    the  edge of the stair see

      uard Requirements tot

    more nform tion

    st ir gu rd height —

    34 measure from

    nosing of

     step

    g u a r d   p o s t -

    t r i a n g u l a r o p e n i n g

      s h a l l n o t

    p e r m i t

      th e

      p a s s a g e

     o f a 6

    d i a m e t e r s p h e r e

    - p r o v i d e   b l o c k i n g   b e t w e e n s t a ir

    s t r i n g e r s

      a t

     g u a r d   p o s t

    locations;  t o e

      n a i l w i t h 1 0 d n a i l s

    to p

     and

     b o t t o m , e a c h  side

    FIGURE

      6:

      STAIR GUARD REQUIREMENTS

    Georgia Amendments

    Prescriptive eck Details

    Sheet

      9 of

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    20/22

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    21/22

    36 min. clear

    1—

     j?̂   all stairs and landings

      N

     -  must be illuminated;

    - . , . • s e e R303.7

    handrail  --

      >̂

    V

    L

    handrail

     shall

    return at each

    en d

    FIGURE

      39:

      MISCELLANEOUS STAIR REQUIREMENTS

    Stair  ighting

    Sta i rways  shal l  be illuminated in  acco rdance with  IR C 303.7.

    Stair Stringer  ootings

    Stair

     stringers

     at

     grade shall bear

     on a

     concrete footing

     as

     shown

     in

     FIGURE

     40. The

     footings

     for

     each

    stringer  may be combined an d poured as a 1 2 deep s lab.

    stringer

    8

    square

      or

     10

    round, 12 deep

    footing

    guard-

    post

      stringer-

    ===3

      a

    FIGURE

     4 :

     STAIR STRINGER

     FOOTING

    Georgia Amendments

    Prescriptive Deck

     Details

    Sheet 2

    of

  • 8/16/2019 2012 Georgia Minimum Residential Prescriptive Deck Details_201401061514101938

    22/22

    SAFETY

     GLAZING

    To reduce injury

      due to an

     acc iden ta l impact safety

      g lazing   in

      w i n dow

      and

      door g lass

      is

      required  when

      th e

    existing  house   wa i l  enc loses  any portion  of the   deck   o r  acts   as a barrier  to   adjacent  stairs landings   and

    th e   areas   at the top and  bottom  of the  stairs.  Glazing shal l  be   located   in the   affected panes   of the   areas

    identified

      be low .

    • Ad jacent  surface   o f  deck : indiv idual pa nes wh ol ly located   in the

      area  identified

      in   FIGURE   41 with a

    total

      pane area greater

      than

      9 sf .

    •  A d jace n t

     s ta i rway :

      indiv idual panes partially  o r  whol ly located   in the   area shown  in   FIGURE   42.

    glass panes wholly

     within

    this area and more than 9

    sf must be safety glazed

    FIGURE

     41:  SAFETY

      GLAZING

      AREA AT

     W LKING

     SURFACE

    glass panes partially  or-

    wholly within this area

    adjacent stairs must

     be

    safety

     glazed

    lower walking

    surface

    walking

      surface

    of

      deck

    FIGURE 42:  SAFETY GLAZING AREA AT STAIRS