Hitachi Air ConditioningProduct Catalogue
Engineering for tomorrow. And the tomorrow after that.
www.hitachiaircon.com | www.hitachiheating.com
Models
Split SystemsSet Free VRF Systems Close Control VentilationDomestic HeatingSamurai Chillers Control Systems
Page
58 - 65 Set Free VRF Systems Mini 2-pipe Side Flow 2-pipe Modular 2 and 3-pipe Combinations CH Boxes System Free indoor units System Free Accessories/Pipe Kits
66 - 69 Close Control Twin DC Inverter
70 - 75 Ventilation KPI Total Energy Recovery KPI Heat Recovery Active Total Energy Recovery Econofresh Kit
76 - 83 Domestic Heating Yutaki-M Monobloc air-to-water heat pump Yutaki-S Split type air-to-water heat pump Accessories
84 - 87 Samurai Chillers Air Cooled Water Cooled Condenserless Cooling Only
88 - 91 Control Systems and Accessories Individual controls Group controls BMS Interface controls Accessories
92 - 116 Helping You Training Warranty Alarm Codes Wiring Diagrams DIP switches Conditions of Sale
Contents
Page
08 Product Range
10 - 17 Wall Mounted RAC S-Series RAC Shirokuma RAC Summit Utopia ES Utopia IVX Utopia Centrifugal
18 - 25 Cassettes RAC Monozone (600x600) Utopia ES 4-Way Utopia ES 2-Way Utopia IVX 4-Way Cassette/2-Way Cassette Utopia IVX Centrifugal 4-Way Cassette/2-Way Cassette
26 - 31 In the Ceiling (ducted) RAC Monozone Utopia ES Utopia IVX Utopia IVX Centrifugal
32 - 37 Ceiling Suspended Utopia ES Utopia IVX Utopia IVX Centrifugal
38 - 43 Floor Mounted RAC Shirokuma RAC NX2 Utopia ES
44 - 49 Multizone Multi Split Systems Multizone Outdoor Units Multizone Indoor Units Combinations RAC Accessories
50 - 57 Twin, Triple and Quad Splits Utopia ES, Centrifugal and IVX Systems
Utopia ES Utopia IVX Utopia IVX Centrifugal System Free Indoor Units System Free Accessories/Pipe Kits Utopia AHU Interface Controllers
Why Hitachi?
With so much to choose from in the market, here are some key reasons to buy from Hitachi’s extensive range of products:
RAC
Our market-leading S-Series wall mounted range has a high COP of 6.13 and high EER of 6.0 for low running costs.
Utopia
No outdoor space, listed building or restrictive covenants? Install Utopia Centrifugal - now with IVX individual control - the Outdoor that’s an Indoor.
Set Free
Comfort protection function across the range – so you won’t hear complaints about cold draughts!
Ventilation
Capacities of up to 2000m3 per hour from a unit that’s less than 650mm high (the lowest height on the market); a compact solution where installation space is limited.
Domestic Heating
Market-leading COP combined with great energy savings (5kW output from 1kW input) – fantastic news for the domestic market when fuel costs are on the increase.
Samurai
Supremely reliable and precise control to within +/- 0.5ºC.
Control Systems and Accessories
H-LINK II across the entire Hitachi product range means you can use Hitachi system free controls for any mix of products.
Heating Manufacturer of the Year “ The judges felt Hitachi provided an excellent submission, a great product and the way forward.”Hitachi’s Yutaki M Heat Pump
Hitachi Product Catalogue | 5
Flexibility built inLook for the System Free logo on all pages featuring our System Free indoor units which can be combined with outdoor units from our Utopia splits or Set Free VRF ranges for the ultimate in flexibility.
Energy saving technologyhttp://etl.decc.gov.uk/etl
Many Hitachi systems have an energy rating of A and are listed on the Energy Technology register: making them eligible for 100% first year enhanced capital allowances. (System cost and reasonable cost of installation).
Quality controlHitachi’s Japanese factories and its overseas affiliates have acquired International Standard Quality Management System ISO9001 and ISO14001 authorisation. The factories perform thorough product quality control using various environmental tests. Hitachi Room Air Conditioning indoor and outdoor units are manufactured according to this ISO certification system.
Hitachi products all carry the necessary ‘CE’ declaration markings, and also feature in the extensive Eurovent Listing programme. Listing in the Eurovent directory helps ensure peace of mind for the installer and the end user, as it certifies the important operating parameters and performance of the units.
World-renowned technologyHitachi manufactured the first screw and scroll compressors in the world (230 patents on 6 components). The performance of Hitachi air conditioning products is greatly improved by the high efficiency high pressure scroll compressors. Hitachi pioneered ‘DC’ Inverter PAM driven Room Air Conditioners and uses this technology to drive its compressors and fans.
Nominal & UK Conditions
Nominal conditions coolingIndoor temperature 27ºC DB, 19ºC WBOutdoor temperature 35ºC DB , 24ºC WB
Nominal conditions heatingIndoor temperature 20ºC DBOutdoor temperature 7ºC DB, 6ºC WB
UK ConditionsIndoor temperature 23ºC DB, 16ºC WBOutdoor temperature 30ºC DB
S Y S T E MFREE
Why Hitachi?
System Free – complete flexibilityHitachi is particularly proud of its System Free concept of indoor units, providing the flexibility to combine indoors with outdoor
units from either the Utopia split systems or Set Free VRF ranges. This gives you enormous scope when planning your climate
solution and facilitates an optimum room climate for all areas.
Utopia outdoor units
Hitachi’s Utopia Split systems range
is available in capacities from 5.0kW
to 33kW. Models include Utopia ES
and IVX, which have a common
cabinet appearance allowing them
to be installed together. The Utopia
Centrifugal units are designed to be
installed indoors with field supplied
ductwork. System free indoor units
and controls are compatible across
the entire range.
Set Free outdoor units
Hitachi’s Set Free range of air
conditioning systems with variable
refrigerant flow (VRF) is available
in capacities from 8kW to 165kW.
Models include Mini 2-pipe,
Side Flow 2-pipe and Modular
2 or 3-pipe system allowing heat
pump or heat recovery options to
suit customer requirements. System
free indoor units and controls are
compatible across the entire range.
Indoor units
Wall-mounted
Cassette
Ceiling-suspended
In the ceiling
Floor-mounted
Total heat exchanger
System Free remote controls and accessories
System free controls can also be used for the RAC* range using PSC-6RAD adapter.
PC-ARTPC-ARF
* excludes S-Series
S Y S T E MFREE
Hitachi Product Catalogue | 7
Functions may vary among the remote controls.
BMS: MODBUS
KNX
CS NET WEB
BACNET
HARC LONWORKS®
CENTRALISED: CS NET WEB
Optional touchscreen
TS002-UK
GROUP: PSC-A64S / PSC-A1T / PSC-A64GT
LOCAL: PC-ARF / PC-ART / PC-ARH / PC-LH3A
Hitachi products also benefit from the versatile range of
System Free controls to fulfil different requirements. The
extensive range includes a variety of wired and wireless
remote controllers as well as the option of different group
controllers. It is also possible to connect all Utopia Splits,
Set Free VRF and Samurai Chillers to Hitachi’s CS Net Web
which provides centralised or remote access control via an
internet connection.
Remote controls
Utopia Split systems Set Free VRF
ES (Simultaneous Operation)
IVX (Individual Operation)
Centrifugal (Simultaneous/individual Operation)
Compatible with System Free indoor units
FS(V)(Y)N2E Mini 2-pipe
FSNM Side Flow 2-pipe
FSXN Modular 2 or 3-pipe
Product Range
Split Systems (kW) 2.0 2.5 3.5 5.0 6.0 7.1 8.0 9.0 10.0 12.5 14.0 20.0 25.0 30.0
Wall Mounted
Cassettes
In the Ceiling (ducted)
Ceiling Suspended
Floor Mounted
Multizone Multi Splits
Utopia ES
Utopia IVX
Utopia Centrifugal
A COP 6.13
COP 4.55
COP 4.17
COP 3.62
COP 4.30
COP 4.11
A
A
A
A
A
COP 3.10B
COP 4.55A
COP 4.47A
Set Free VRF (kW) 8 11 14 16 22 28 33 40 45 50 56 63 69
Mini 2-pipe
Side Flow heat pump (2-pipe)
Modular heat pump (2-pipe)
Modular heat recovery (3-pipe)
Samurai (kW) 112 130 156 178 206 260 312 356 400 412
Air Cooled (Cooling Only)
Air Cooled (Heat Pump)
Water Cooled
Conderserless
Ventilation (m3/hr)* 250 500 800 1000 1500 2000
Total Energy Recovery
Heat Recovery
Active Total Energy Recovery
*Econofresh also available
73 80 85 90 96 101 107 113 118 124 130 135 140 145 150
468 534 618 712 824 890 1030
For full details, refer to Technical Manual
COP 4.17
COP 4.17
A
A
A COP 4.14
A COP 4.55
Domestic Heating (kW) 5 8 10 12.5 14 20 24
Yutaki - M
Yutaki - S
A COP 4.50
COP 5.01A
Close Control 56
Twin DC Inverter
A ESEER 3.52
ESEER 3.45A
A ESEER 4.86
ESEER 4.32A
A EER 2.80
Wall Mounted
Features and Benefits
All RAC Wall mounted units
RAC S-Series
33 per year*
* Based upon 500 hours of 100% run time with a cost of 8 pence / 16 cents per kW/hr on 2.5 kW unit
RAC Shirokuma
compliment any interior
RAC Summit
Utopia Wall Mounted
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
Hitachi Product Catalogue | 11
Product Summary S-Series RAS 18~35SX8
Shirokuma RAS 25~50WX8(W)(B)
Summit RAS 18~80FH6/FH7/YH5A
Utopia ESRPK 2~4.0FSN2M
Utopia IVXRPK 3~4.0FSN2M
Utopia CentrifugalRPK 3.0FSN2M
Nominal Cooling Capacity (kW) 1.8 ~ 3.5 2.5 ~ 5.0 2.0 ~ 8.0 5.0 ~ 10.0 7.1 ~ 10.0 7.1
Nominal Heating Capacity (kW) 2.1 ~ 4.2 3.4 ~ 6.3 2.5 ~ 9.3 5.6 ~ 11.2 8.0 ~ 11.2 8.0
Refrigerant R410A R410A R410A R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter
Operating Range¹ (Cooling) -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -5ºC / +43ºC
Operating Range (Heating) -20ºC / +21ºC -15ºC / +21ºC -15ºC / +21ºC -10ºC / +15ºC (*) -20ºC / +15ºC -15ºC / +15ºC
Std. Remote Controller Type Infra Red Infra Red Infra Red Wired or Infra Red Wired or Infra Red Wired or Infra Red
Remote Control Timer - 24hr or 7 Day
Option24hr or 7 Day
Option24hr or 7 Day
Option24hr or 7 Day
Option24hr or 7 Day
Option
¹ Selected Models (*) -15ºC 2.0/2.5 models
RAC S-Series
Outdoor Units
Wall Mounted
For full technical details refer to Technical Manual
RAS 18SX8 RAS 25SX8 RAS 35SX8
Nominal Capacity (Min ~ Max) (kW)Cooling 1.8 (0.5~2.4) 2.5 (0.5~3.4) 3.5 (0.5~4.1)
Heating 2.1 (0.6~4.4) 3.2 (0.6~6.1) 4.2 (0.6~7.6)
UK Cooling Capacity (kW)Total 1.9 2.7 4.3
Sensible 1.7 2.4 2.8
EER/COPCooling 6.00 5.38 4.19
Heating 6.13 5.47 4.80
Energy LabelCooling A A A
Heating A A A
Indoor Sound Pressure Level dB(A)Cooling 38/32/26/20 42/34/28/20 43/34/28/20
Heating 39/33/27/23 42/35/30/20 44/35/30/20
Indoor Fan (m3/min)Cooling 8.0/6.2/4.5/3.5 11.5/8.3/7.2/5.2 11.9/8.8/8.1/5.2
Heating 9.5/7.0/5.5/3.3 12.5/9.0/8.0/5.3 13.4/10.2/9.0/5.3
Dimensions (mm) & Weight (kg)
Height 298
Width 793
Depth 233
Weight 11.5
RAC 18SX8 RAC 25SX8 RAC 35SX8
Outdoor Sound Pressure Level dB(A)Cooling 45 45 46
Heating 46 45 46
Dimensions (mm) & Weight (kg)
Height 570
Width 750
Depth 288
Weight 36
Operating Range (ºC)Cooling -10 ~ +43
Heating -20 ~ +21
Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
Gas 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
Piping (m)
Length 20
Lift 10
Pre-charged 20
Power Supply 230V 1ph 50Hz
Power to Indoor & Outdoor
Interconnecting Cables No. 4 4 4
Starting Current (A) 5.8 5.8 6.2
Running Current (230v) (A)Cooling 2.87 2.87 4.35
Heating 3.72 3.72 4.49
Recommended Fuse Size (A) 16 16 16
RAC-SX8
RAR-3R5 RAS-SX8
For full technical details refer to Technical Manual
Outdoor Units
Wall Mounted
Hitachi Product Catalogue | 13
RAC Shirokuma
RAC-WX8
RAS-WX8 RAS-WX8
RAS 25WX8 (W/B) RAS 35WX8 (W/B) RAS 50WX8 (W/B)
Nominal Capacity (Min ~ Max) (kW)Cooling 2.5 (0.9~3.1) 3.5 (0.9~4.0) 5.0 (0.9~5.2)
Heating 3.4 (0.9~4.4) 4.2 (0.9~5.0) 6.3 (0.9~7.5)
UK Cooling Capacity (kW)Total 2.2 2.7 4.3
Sensible 2.0 2.4 2.8
EER/COPCooling 4.31 3.57 3.22
Heating 4.30 4.16 3.61
Energy LabelCooling A A A
Heating A A A
Indoor Sound Pressure Level dB(A)Cooling 38/32/26/20 41/35/29/22 48/39/31/25
Heating 39/33/27/23 41/35/30/22 48/39/31/25
Indoor Fan (m3/min)Cooling 8.0/6.2/4.5/3.5 9.7/7.0/5.6/4.6 11.5/9.2/6.8/4.8
Heating 9.5/7.0/5.5/3.3 10.3/8.5/6.6/4.4 13.0/9.6/7.3/4.8
Dimensions (mm) & Weight (kg)
Height 295
Width 795
Depth 198
Weight 10
RAC 25WX8 RAC 35WX8 RAC 50WX8
Outdoor Sound Pressure Level dB(A)Cooling 45 46 50
Heating 46 47 52
Dimensions (mm) & Weight (kg)
Height 548 600
Width 750 792
Depth 288 299
Weight 35 42
Operating Range (ºC)Cooling -10 ~ +43
Heating -15 ~ +21
Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)
Piping (m)
Length 20 30
Lift 10 10
Pre-charged 20 30
Power Supply 230V 1ph 50Hz
Power to Outdoor
Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened
Starting Current (A) 3.9 4.7 8.1
Running Current (230v) (A)Cooling 2.87 4.35 6.83
Heating 3.72 4.49 7.66
Recommended Fuse Size (A) 16 16 16
RAR-3U4
hitachiaircon.com Email: [email protected]: 01628 585 394
Outdoor Units
Wall Mounted
For full technical details refer to Technical Manual
RAC Summit
RAS 18FH6 RAS 25FH6 RAS 35FH6 RAS 50FH7 RAS 60YH7 RAS 70YH7 RAS 80YH5A
Nominal Capacity (Min~Max) (kW)
Cooling 2.0(0.9~2.5) 2.5(0.9~3.1) 3.5(0.9~4.0) 5.0(0.9~5.2) 6.05(0.9~6.5) 7.0(0.9~8.0) 8.0(1.5~8.5)
Heating 2.5(0.9~3.2) 3.4(0.9~4.4) 4.2(0.9~5.0) 6.5(0.9~8.1) 7.05(0.9~9.0) 8.2(0.9~9.5) 9.3(1.5~9.7)
UK Cooling Capacity (kW)Total 1.9 2.4 3.3 4.2 5.3 6.47 7.4
Sensible 1.7 2.0 2.5 3.1 4.0 4.8 5.4
EER/COP Cooling 3.64 3.57 3.21 3.20 3.24 3.23 2.61
Heating 4.31 3.86 3.78 3.82 3.62 3.64 3.00
Energy LabelCooling A A A A A A D
Heating A A A A A A D
Indoor Sound Pressure Level (dB(A)
Cooling 35/32/26/20 38/32/26/20 42/35/29/25 47/39/28/24 48/42/33/30 47/42/33/30 46/43/40/36
Heating 36/33/27/23 39/33/27/23 42/35/30/26 47/39/31/27 49/42/34/33 47/42/33/30 47/44/41/39
Indoor Fan (m3/min)
Cooling 7.3/6.7/5.8/5.2 8.5/7.0/6.05.4 10.0/8.0/6.5/5.7 12.0/9.5/6.5/5.5 15.5/11.5/9.0/8.0 17.0/15.5/10.5/8.5 19.0/16.5/13.5/12.1
Heating 8.0/7.0/5.8/5.5 9.5/8.0/7.0/5.8 10.8/8.5/7.5/6.1 12.5/10.0/7.0/6.0 17.5/12.0/8.5/8.0 18.0/14.5/10.5/8.5 19.0/16.5/13.5/12.8
Dimensions (mm) & Weight (kg)
Height 280 295 330
Width 780 1030 1150
Depth 220 207 245
Weight 9.5 12 15 15
RAC 18YH6 RAC 25YH6 RAC 35YH6 RAC 50YH7 RAC 60YH7 RAC 70YH7 RAC 80YH5
Outdoor Sound Pressure Level dB(A)
Cooling 44 46 46 50 50 52 55
Heating 46 48 49 52 53 54 57
Dimensions (mm) & Weight (kg)
Height 550 548 650 800 875
Width 700 750 850 850 925
Depth 258 288 298 298 315
Weight 27 35 45 55 75
Operating Range (ºC)Cooling -10~43
Heating -15~21
Refrigerant Piping (mm) (in)
Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4)
Gas 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8)
Piping (m)
Length 20 30
Lift 10 20
Pre-charged
20 20
Power Supply 230V 1ph 50Hz
Power to Outdoor
Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened 2 Core Screened 4 Core Screened 4 Core Screened 4 Core Screened
Starting Current (A) 3.0 4.5 5.3 7.1 10.0 10.0 14.0
Running Current (230v) (A)Cooling 3.0 3.8 5.2 7.2 8.5 10.0 14.1
Heating 2.9 4.5 5.3 7.6 8.6 10.1 14.3
Recommended Fuse Size (A) 16 16 16 16 16 20 30
RAC-YH6
RAS-YH5A RAS-FH6/7 RAR-3U1/3
RAC-YH7
For full technical details refer to Technical Manual
Hitachi Product Catalogue | 15
Utopia ES
Outdoor Units
Wall MountedRPK-FSN2M
RAS-HVRNS2(E)
PC-ART
RPK 2.0FSN2M RPK 2.5FSN2M RPK 3.0FSN2M RPK 4.0FSN2M
Nominal Capacity (Min ~ Max) (kW)Cooling 5.0 (2.0 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2)
Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5)
UK Cooling Capacity (kW)Total 5.2 5.8 7.5 10.6
Sensible 3.7 4.2 5.3 7.5
EER/COPCooling 3.14 2.96 2.82 2.61
Heating 3.21 3.00 3.08 2.81
Energy LabelCooling B C C D
Heating C D D D
Indoor Sound Pressure Level dB(A) 41/39/37 43/40/37 43/40/37 49/46/43
Indoor Fan (m3/min) 14/12/10 17/16/14 17/16/14 22/20/17
Dimensions (mm) & Weight (kg)
Height 295 333
Width 1030 1150
Depth 208 245
Weight 12 18
Recommended Fuse Size (A) 5 5 5 5
Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRNS2 RAS 4.0HVRNS2E
Outdoor 3Ø - - - RAS 4.0HRNS2E
Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 45 (43) 46 (44) 48 (46) 50 (48)
Heating 47 48 50 52
Dimensions (mm) & Weight (kg)
Height 600 800
Width 792 950
Depth 300 370
Weight 1Ø/3Ø 42 / - 44 / - 79 / 79
Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db
Heating (-15 ~ 15)wb (-10 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 9.52 (3/8) 9.52 (3/8)
Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8)
Piping (m)
Length 50 50 30 50
Lift 30 30 30 30
Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m
Power Supply1 Phase 1Ph 220-240V 50Hz
3 Phase - 3Ph 380-415V 50Hz
Power to Outdoor
Interconnecting Cables No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)Cooling 6.9 8.8 11.0 14.2
Heating 7.6 10.2 11.3 13.8
Recommended Fuse Size (1Ø/3Ø) (A) 16 / - 20 / - 25 / - 32 / 16
S Y S T E MFREE
hitachiaircon.com Email: [email protected]: 01628 585 394
Outdoor 1Ø RAS 3.0HVRNM2E RAS 4.0HVRNM2E
Outdoor 3Ø - RAS 4.0HRNM2E
Outdoor Sound Pressure Level (Set Back) d(B)A
Cooling 47 (43) 49 (45)
Heating 49 51
Dimensions (mm) & Weight (kg)
Height 800 1380
Width 950 950
Depth 370 370
Weight 1Ø/3Ø 67/- 98/98
Operating Range (ºC)Cooling (-10 ~ 46)db
Heating (-20 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8)
Gas 15.88(5/8) 15.88(5/8)
Piping (m)
Length 50 70
Lift 30 30
Pre-charged 30 / 40g/m 30 / 60g/m
Power Supply1 Phase 1Ph 220-240V 50Hz
3 Phase - 3Ph 380-415V 50Hz
Power To Outdoor Outdoor
Interconnection wires No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10
Running Current (1Ø/3Ø) (A)Cooling 10.3 / - 13.5 / 4.8
Heating 11.3 / - 15.6 / 5.5
Recommended Fuse Size (1Ø/3Ø) (A) 20 / - 32 / 16
Outdoor Units
Wall Mounted
Utopia IVX
RPK-FSN2M PC-ART
RAS-HVRNME
RPK 3.0FSN2M RPK 4.0FSN2M
Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2)
Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0)
UK Cooling Capacity (kW)Total 7.5 10.6
Sensible 5.3 7.5
EER/COP Cooling 3.02 3.22
Heating 3.10 3.13
Energy LabelCooling B A
Heating D D
Indoor Sound Pressure Level dB(A) 43/40/37 49/46/43
Indoor Fan m3/min 17/16/14 22/20/17
Dimensions (mm) & Weight (kg)
Height 333
Width 1150
Depth 245
Weight 18
Recommended Fuse Size (A) 5 5
S Y S T E MFREE
Hitachi Product Catalogue | 17
Wall Mounted
Outdoor Units
Utopia Centrifugal
RPK 3.0FSN2M
Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.2 ~ 8.0)
Heating 8.0 (3.5 ~ 9.0)
UK Cooling Capacity (kW)Total 7.5
Sensible 5.3
EER/COP Cooling 2.64
Heating 2.62
Energy LabelCooling D
Heating E
Indoor Sound Pressure Level dB(A) 43/40/37
Indoor Fan m3/min 17/16/14
Dimensions (mm) & Weight (kg)
Height 333
Width 1150
Depth 245
Weight 18
Recommended Fuse Size (A) 5
RASC 3.0HVRNE
Outdoor Sound Pressure Level dB(A)Cooling 46
Heating 46
Dimensions (mm) & Weight (kg)
Height 430
Width 1250
Depth 1300
Weight 168
Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44
Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15
Operating Range (ºC)Cooling (-5 ~ 43)db
Heating (-15 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8)
Gas 15.88(5/8)
Piping (m)
Length 30
Lift 30
Pre-charged 20 / 60g/m
Power Supply 1 Phase 1Ph 220-240V 50Hz
Power To Outdoor
Interconnecting Cables No. LNE + 2 Core Screened
Starting Current (A) < 10
Running Current (A)Cooling 11.3
Heating 11.9
Recommended Fuse Size (A) 32
RASC-HVRNE
RPK-FSN2M PC-ART
S Y S T E MFREE
hitachiaircon.com Email: [email protected]: 01628 585 394
Product Summary
RAC Monozone
600x600 cassetteRAI 25~50NH5A
Utopia ES
600x600RCIM 2.0FSN2
Utopia ES
4-WayRCI 2.0 ~ 6.0FSN3E
2-WayRCD 2.0 ~ 5.0FSN2
Nominal Cooling Capacity (kW) 2.5 ~ 5.0 5.0 5.0 ~ 14.0 5.0 ~ 12.5
Nominal Heating Capacity (kW) 3.5 ~ 6.5 5.6 5.6 ~ 16.0 5.6 ~ 14.0
Refrigerant R410A R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter
Operating Range¹ (Cooling) (db) -10ºC / +43ºC -5ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC
Operating Range (Heating) (wb) -15ºC / +15ºC -15ºC / +15ºC -10ºC / +15ºC (*) -10ºC / +15ºC (*)
Std. Remote Controller Type Infra Red Wired or Infra Red Wired or Infra Red Wired or Infra Red
Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option
Condensate Pump Yes Yes Yes Yes
¹ Selected Models (*) -15ºC 2.0/2.5 models (*) -15ºC 2.0/2.5 models
Features and Benefits
Cassettes
RAC Monozone 600 x 600 Cassette
The 600mm x 600mm ceiling unit neatly fits inside a standard ceiling module which minimises installation work
The user can select between 2-Way, 3-Way or 4-Way operation of auto swing louvres
Utopia 4-Way Cassette
COP 4.55 and EER 3.97
The depth of the units vary from just 248 to 298mm, so they can be installed in a reduced space inside a false ceiling
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
Hitachi Product Catalogue | 19
Utopia IVX Utopia IVX Centrifugal**
4-WayRCI 3.0 ~ 6.0FSN3E
2-WayRCD 3.0 ~ 5.0FSN2
4-WayRCI 3.0 ~ 5.0FSN3E
2-WayRCD 3.0 ~ 5.0FSN2
7.1 ~ 14.0 7.1 ~ 12.5 7.1 ~ 12.5 7.1 ~ 12.5
8.0 ~ 16.0 8.0 ~ 16.0 8.0 ~ 14.0 8.0 ~ 14.0
R410A R410A R410A R410A
DC-Inverter DC-Inverter DC-Inverter DC-Inverter
-10ºC / +43ºC -10ºC / +43ºC -5ºC / +46ºC -5ºC / +46ºC
-15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC
Wired or Infra Red Wired or Infra Red Wired or Infra Red Wired or Infra Red
24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option
Yes Yes Yes Yes
** 3HP Std. Inverter Centrifugal ** 3HP Std. Inverter Centrifugal
Utopia 2-Way Cassette
The compact turbo fan simplifies the structure and reduces the height of the unit to 298mm. The unit’s low profile design allows easy installation in the most confined spaces inside a ceiling
with built in 7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
Outdoor Units
600x600 Cassette
For full technical details, refer to Technical Manual
RAC Monozone
RAI 25NH5A RAI 35NH5A RAI 50NH5A
Nominal Capacity (Min ~ Max) (kW)Cooling 2.5(0.9~3.0) 3.5(0.9~4.0) 5.0(0.9~5.2)
Heating 3.5(0.9~5.0) 4.8(0.9~6.6) 6.5(0.9~8.1)
UK Cooling Capacity (kW)Total 2.3 3.2 4.1
Sensible 1.8 2.4 3.0
EER/COPCooling 3.60 3.18 2.51
Heating 3.72 3.53 3.01
Energy LabelCooling A B E
Heating A B D
Indoor Sound Pressure Level (dB(A)Cooling 35/32/29/25 39/34/29/26 43/35/32/29
Heating 36/33/30/27 40/36/32/29 43/36/32/30
Indoor Fan (m3/min)Cooling 8.5/7.0/5.8/5.5 10.8/8.0/5.8/5.5 12.0/8.0/5.8/5.5
Heating 8.5/7.0/5.8/5.5 10.8/8.0/5.8/5.5 12.0/8.0/5.8/5.5
Dimensions (mm) & Weight (kg)(Panel RAI-ECPM)
Height 285
Width 580
Length 580
Panel 32/650/650
Weight 20 (4)
RAI-NH5ARAI-NH5ARAI-NH5A
RAC-NH5 RAR-3U1
RAC 25NH5 RAC 35NH5 RAC 50NH5
Outdoor Sound Pressure Level dB(A)Cooling 46 47 50
Heating 46 49 52
Dimensions (mm) & Weight (kg)
Height 570 650
Width 750 850
Depth 280 298
Weight 38 45
Operating Range (ºC)Cooling -10 ~ +43
Heating -15 ~ +21
Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)
Piping (m)
Length 20
Lift 10
Pre-charged 20
Power Supply AC 1Ph 220~230V 50Hz
Power to Outdoor
Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened
Starting Current (A) 4.2 6.1 10.0
Running Current (230v) (A)Cooling 3.05 4.85 8.74
Heating 4.15 6.00 9.49
Recommended Fuse Size (A) 16 16 16
Hitachi Cassettes
2-way, 3-way and 4-way air outlet controlthat can be used in ceiling heights of up to 4.2m
Contact [email protected] to find out more
Hitachi Product Catalogue | 21
RAS-HVRN2S RAS-HVRNS2(E)RAS-HVRNM2E
RCIM 2.0FSN2 RCI 2.0FSN3E RCI 2.5FSN3E RCI 3.0FSN3E RCI 4.0FSN3E RCI 5.0FSN3E RCI 6.0FSN3E
Mini 600x600 4-Way 4-Way 4-Way 4-Way 4-Way 4-Way
Nominal Capacity (Min-Max) (kW)
Cooling 5.0 (2.2 ~ 5.6) 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0)
Heating 5.6 (2.2 ~ 7.1) 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0) 16.0 (6.0 ~ 18.0)
UK Cooling Capacity (kW)
Total 5.3 5.3 5.9 7.5 10.6 13.1 15.6
Sensible 3.8 4.1 4.3 5.9 8.3 9.7 11.4
EER/COP Cooling 3.11 3.97 3.28 3.06 3.01 2.91 2.45
Heating 3.31 4.55 3.80 3.29 3.48 3.24 2.88
Energy LabelCooling B A A B B C E
Heating C A A C B C DIndoor Sound Pressure Level dB(A) 42/39/37 32/30/28 32/30/28 34/32/30 38/35/33 39/37/35 42/40/36
Indoor Fan (m³/min) 16/14/12 16/14/12 20/17/15 26/23/20 32/28/24 34/29/25 37/32/27
Dimensions (mm) & Weight (kg)
Height 295 248
Width 570 840
Depth 570 840
Grille 700/700/35 950/950/37
Weight 17 (3.5) 24 (6) 26 (6)Recommended Fuse Size (A) 5 5 5 5 5 5 5
Outdoor 1Ø RAS 2.0HVRN2 RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E
Outdoor 3Ø - - - - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E
Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 45 (43) 45 (43) 46 (44) 48 (46) 50 (48) 52 (50) 55 (53)
Heating 47 47 48 50 52 54 57
Dimensions (mm) & Weight (kg)
Length 600 600 800
Width 792 792 950
Depth 300 300 370
Weight 1Ø/3Ø 42 / - 42 / - 42 / - 44 / - 79 / 79 83 / 83 83 / 83
Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db (-10 ~ 43)db
Heating (-10 ~ 15)wb (-10 ~ 15)wb (-10 ~ 15)wb
Refrigerant Piping (mm) (in)
Liquid 6.35(1/4) 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gas 12.7(1/2) 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Piping (m)
Length 50 50 50 30 50 50 50
Lift 30 30 30 30 30 30 30
Pre-charged 30 / 30g/m 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m 30 / 60g/m
Power Supply1 phase 1Ph 220-240V
50Hz 1Ph 220-240V 50Hz
3 phase - - - - 3Ph 380-415V 50Hz
Power To Outdoor Outdoor
Interconnection wires No. LNE + 2 Core Screened LNE + 2 Core Screened
Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)
Cooling 6.8 5.4 7.8 9.9 15.4 / 5.0 18.4 / 6.5 24.6 / 8.7
Heating 7.2 5.2 7.9 10.4 14.9 / 4.9 18.5 / 6.6 23.8 / 8.4Recommended Fuse Size (1Ø/3Ø) (A) 16 / - 16 / - 20 / - 25 / - 32 / 16 32 / 16 32 / 16
Outdoor Units
Utopia ES
4-Way CassetteRCI-FSN3E PC-ART RCIM-FSN2
S Y S T E MFREE
Hitachi Product Catalogue | 23
RCD 2.0FSN2 RCD 2.5FSN2 RCD 3.0FSN2 RCD 4.0FSN2 RCD 5.0FSN2
2-Way 2-Way 2-Way 2-Way 2-Way
Nominal Capacity (Min-Max) (kW)
Cooling 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0)
Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0)
UK Cooling Capacity (kW)
Total 5.3 5.9 7.5 10.6 13.1
Sensible 4.0 4.4 5.6 7.7 9.7
EER/COP Cooling 3.14 2.87 2.81 3.01 3.03
Heating 3.09 3.13 3.08 3.48 3.31
Energy LabelCooling B C C B B
Heating D D D B CIndoor Sound Pressure Level dB(A) 35/32/30 38/34/31 38/34/31 40/36/33 43/40/36
Indoor Fan (m³/min) 15/13/11 19/16/14 19/16/14 29/24/21 34/29/25
Dimensions (mm) & Weight (kg)
Height 298 298
Width 620 620
Depth 860 1420
Grille 1100/710/30 1660/710/30
Weight 27 (6) 30 (6) 30 (6) 48 (8)Recommended Fuse Size (A) 5 5 5 5 5
Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E
Outdoor 3Ø - - - RAS 4.0HRNS2E RAS 5.0HRNS2E
Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 45 (43) 46 (44) 48 (46) 50 (48) 52 (50)
Heating 47 48 50 52 54
Dimensions (mm) & Weight (kg)
Length 600 800
Width 792 950
Depth 300 370
Weight 1Ø/3Ø 42 / - 42 / - 44 / - 79 / 79 83 / 83
Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db
Heating (-10 ~ 15)wb (-10 ~ 15)wb
Refrigerant Piping (mm) (in)
Liquid 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Piping (m)
Length 50 50 30 50 50
Lift 30 30 30 30 30
Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m
Power Supply1 phase 1Ph 220-240V
50Hz
3 phase - - - 3Ph 380-415V 50Hz
Power To Outdoor
Interconnection wires No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)
Cooling 6.7 / - 8.8 / - 10.8 / - 15.4 / 5.4 17.5 / 6.2
Heating 7.7 / - 9.5 / - 11.1 / - 14.9 / 5.3 17.9 / 6.3Recommended Fuse Size (1Ø/3Ø) (A) 16 / - 20 / - 25 / - 32 / 16 32 / 16
Outdoor Units
2-Way CassetteRCD-FSN2 PC-ART
Utopia ES
RAS-HVRN2S RAS-HVRNS2(E)
For full technical details, refer to Technical Manual
S Y S T E MFREE
hitachiaircon.com Email: [email protected]: 01628 585 394
Outdoor Units
Utopia IVX
4-Way / 2-Way CassetteRCI-FSN3ERCD-FSN2 PC-ART
* 3HP Std. Inverter Centrifugal.
RAS-HVRNM2E
RCI 3.0FSN3E RCI 4.0FSN3E RCI 5.0FSN3E RCI 6.0FSN3E RCD 3.0FSN2 RCD 4.0FSN2 RCD 5.0FSN2
4-Way 4-Way 4-Way 4-Way 2-Way 2-Way 2-Way
Nominal Capacity (Min-Max) (kW)
Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0) 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0)
Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0) 16.0 (6.0 ~ 20.0) 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0)
UK Cooling Capacity (kW)
Total 7.5 10.6 13.1 15.6 7.5 10.6 13.1
Sensible 5.9 8.3 9.7 11.4 5.6 7.7 9.7
EER/COP Cooling 3.66 3.90 3.62 3.29 3.05 3.47 3.31
Heating 4.05 4.10 4.06 3.72 3.30 3.41 3.70
Energy LabelCooling A A A A B A A
Heating A A A A C B AIndoor Sound Pressure Level dB(A) 34/32/30 38/35/33 39/37/35 42/40/36 38/34/31 40/36/33 39/37/35
Indoor Fan (m³/min) 26/23/20 32/28/24 34/29/25 37/32/27 19/16/14 29/24/21 34/29/25
Dimensions (mm) & Weight (kg)
Height 840 860 1420
Width 840 620 620
Depth 298 298 298
Grille 950/950/37 1100/710/30 1660/710/30
Weight 26 (6) 30 (6) 48 (8)Recommended Fuse Size (A) 5 5 5 5 5 5 5
Outdoor 1Ø RAS 3.0HVRNM2E
RAS 4.0HVRNM2E
RAS 5.0HVRNM2E
RAS 6.0HVRNM2E
RAS 3.0HVRNM2E
RAS 4.0HVRNM2E
RAS 5.0HVRNM2E
Outdoor 3Ø - RAS 4.0HRNM2E
RAS 5.0HRNM2E
RAS 6.0HRNM2E - RAS
4.0HRNM2ERAS
5.0HRNM2E
Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 47 (43) 49 (45) 51 (47) 51 (48) 47 (43) 49 (45) 51 (47)
Heating 49 51 53 53 49 51 53
Dimensions (mm) & Weight (kg)
Length 800 1380 800 1380
Width 950 950 950 950
Depth 370 370 370 370
Weight 1Ø/3Ø 67 / - 98 / 98 105 / 105 105 / 105 67 / - 98 / 98 105 / 105
Operating Range (ºC)Cooling (-10 ~ 46)db (-10 ~ 46)db
Heating (-20 ~ 15)wb (-20 ~ 15)wb
Refrigerant Piping (mm) (in)
Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Piping (m)
Length 50 70 75 75 50 70 75
Lift 30 30 30 30 30 30 30
Pre-charged 30 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 60g/m 30 / 40g/m 30 / 60g/m 30 / 60g/m
Power Supply1 phase 1Ph 220-240V 50Hz 1Ph 220-240V 50Hz
3 phase - 3Ph 380-415V 50Hz - 3Ph 380-415V 50Hz
Power To Outdoor Outdoor
Interconnection wires No. LNE + 2 Core screened LNE + 2 Core screened
Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)
Cooling 8.2 / - 10.9 / 3.9 14.7 / 5.2 18.1 / 6.4 9.9 / - 12.2 / 4.3 15.9 / 5.6
Heating 8.4 / - 11.6 / 4.1 14.7 / 5.2 18.3 / 6.5 10.3 / - 14.0 / 4.9 15.9 / 5.6Recommended Fuse Size (1Ø/3Ø) (A) 25 32 / 16 32 / 16 32 / 16 25 32 / 16 32 / 16
S Y S T E MFREE
Hitachi Product Catalogue | 25
RASC-HVRN(M)E
RCI 3.0FSN3E RCD 3.0FSN2 RCI 5.0FSN3E RCD 5.0FSN2
4-Way 2-Way 4-Way 2-Way
Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.4 ~ 8.0) 7.1 (3.4 ~ 8.0) 12.5 (4.7 ~ 14.0) 12.5 (4.7 ~ 14.0)
Heating 8.0 (3.4 ~ 9.0) 8.0 (3.4 ~ 9.0) 14.0 (5.0 ~ 16.0) 14.0 (5.0 ~ 16.0)
UK Cooling Capacity (kW)Total 7.5 7.5 13.1 13.1
Sensible 5.9 5.6 9.7 9.0
EER/COP Cooling 2.90 2.78 2.71 2.69
Heating 3.10 2.69 3.10 3.01
Energy LabelCooling C D D D
Heating D E D D
Indoor Sound Pressure Level dB(A) 34/32/30 38/34/31 39/37/35 43/40/36
Indoor Fan (m3/min) 26/23/20 19/16/14 34/29/25 34/29/25
Dimensions (mm) & Weight (kg)
Height 840 860 840 1420
Width 840 620 840 620
Depth 298 298 298 298
Grille 950/950/38 1100/710/30 950/950/38 1660/710/30
Weight 26 (6) 30 (6) 26 (6) 48 (8)
Recommended Fuse Size (A) 5 5 5 5
RASC 3.0HVRNE* RASC 5.0HVRNME
Outdoor Sound Pressure Level dB(A)Cooling 46 55
Heating 46 56
Dimensions (mm) & Weight (kg)
Height 430 430
Width 1250 1250
Depth 1300 1300
Weight 168 176
Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44 60 / 65/ 69
Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15 100 / 50 / 12
Operating Range (ºC)Cooling (-5 ~ 43)db (-5 ~ 46)db
Heating (-15 ~ 15)wb (-15 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8)
Gas 15.88(5/8) 15.88(5/8)
Piping (m)
Length 30 70
Lift 30 30
Pre-charged 20 / 60g/m 15 / 60g/m
Power Supply 1 Phase 1Ph 220-240V 50Hz 1Ph 220-240V 50Hz
Power To Outdoor Outdoor
Interconnecting Cables No. LNE + 2 Core Screened LNE + 2 Core Screened
Starting Current (A) < 10 < 10
Running Current (230v) (A)Cooling 11.3 22
Heating 11.9 21.6
Recommended Fuse Size (A) 32 40
Utopia IVX Centrifugal
Outdoor Units
4-Way / 2-Way CassetteRCI-FSN3ERCD-FSN2 PC-ART
* 3HP Std. Inverter Centrifugal.For full technical details, refer to Technical Manual
S Y S T E MFREE
hitachiaircon.com Email: [email protected]: 01628 585 394
Features and Benefits
In the Ceiling (ducted)
RAC Monozone In the Ceiling (ducted)
The units are only 750mm long and 235mm in depth
Air intake direction can be horizontal or vertical by interchanging the bottom panel with the fan cover
ready to connect to PCS-6RAD adapter.
Monozone In the Ceiling
Utopia In the Ceiling (ducted)
COP of 4.17 and EER of 3.72
The RPI has a reinforced structure to give the unit more rigidity when it is suspended. It also has one of the lowest heights in the market when it’s installed
The unit has 3 static pressure settings providing greater installation flexibility and can be adapted to suit the installation requirements
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
Hitachi Product Catalogue | 27
Product Summary MonozoneRAD 25 ~ 35NH7A
Utopia ESRPI 2.0 ~ 10.0FSN3E
Utopia IVXRPI 3.0 ~ 10.0FSN3E
Utopia IVX Centrifugal*RPI 3.0 ~ 10.0FSN3E
Nominal Cooling Capacity (kW) 2.5 ~ 3.5 5.0 ~ 25.0 7.1 ~ 25.0 7.1 ~ 25.0
Nominal Heating Capacity (kW) 3.5 ~ 4.8 5.6 ~ 28.0 8.0 ~ 28.0 8.0 ~ 28.0
Refrigerant R410A R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter
Operating Range1 (Cooling) (db) -10ºC / +43ºC -5ºC / +43ºC -15ºC / +43ºC (*) -5ºC / +46ºC
Operating Range (Heating) (wb) -15ºC / +15ºC -10ºC / +15ºC (*) -20ºC / +15ºC -15ºC / +15ºC
Std. Remote Controller Type Wired Wired or Infra Red Wired or Infra Red Wired or Infra Red
Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option
Condensate Pump Yes Yes# Yes# Yes#
Static Pressure (Pa) Adjustable Adjustable Adjustable Adjustable
Return Air Direction Rear or Bottom Rear or Bottom# Rear or Bottom# Rear or Bottom#
¹ Selected Models(*) -15ºC 2.0/2.5 models
#Option available on 8HP and 10HP(*) -10ºC 3.0~ 6.0 models
#Option available on 8HP and 10HP* 3HP Std. Inverter Centrifugal
#Option available on 8HP and 10HP
Outdoor Units
In the Ceiling (ducted)
For full technical details, refer to Technical Manual
RAC Monozone
RAD 25NH7A RAD 35NH7A
Nominal Capacity (Min ~ Max) (kW)Cooling 2.5(0.9~3.0) 3.5(0.9~4.0)
Heating 3.5(0.9~5.0) 4.8(0.9~6.6)
UK Cooling Capacity (kW)Total 2.3 3.2
Sensible 1.8 2.2
EER/COPCooling 3.60 2.82
Heating 3.61 2.82
Energy LabelCooling A C
Heating A D
Indoor Sound Pressure Level dB(A)Cooling 36/34/31/29 36/34/31/29
Heating 37/33/30/27 37/33/30/27
Indoor Fan (m3/min)Cooling 8.2/7.3/6.2/5.5 8.5/7.6/6.2/5.5
Heating 9.2/7.5/6.2/5.5 9.3/7.6/6.2/5.5
Static Pressure (Pa) Standard 30 (low 25, High 35)
Dimensions (mm) & Weight (kg)
Height 235
Width 750
Length 400
Weight 19
RAC 25NH5 RAC 35NH5
Outdoor Sound Pressure Level dB(A)Cooling 46 47
Heating 46 49
Dimensions (mm) & Weight (kg)
Height 570
Width 750
Depth 280
Weight 38
Operating Range (ºC)Cooling -10 ~ +43
Heating -15 ~ +21
Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4)
Gas 9.52 (3/8) 9.52 (3/8)
Piping (m)
Length 20
Lift 10
Pre-charged 20
Power Supply 230V 1 ph 50Hz
Power to Outdoor
Interconnecting Cables No. 2 Core Screened 2 Core Screened
Starting Current (A) 4.2 6.1
Running Current (230v) (A)Cooling 3.05 5.45
Heating 4.26 7.47
Recommended Fuse Size (A) 16 16
RAD-NH7A PM RAD 18 NH7
RAC-NH5
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 29
Utopia ES
In the Ceiling (ducted)PC-ARTRPI-FSN3E
Outdoor Units
RPI 2.0FSN3E RPI 2.5FSN3E RPI 3.0FSN3E RPI 4.0FSN3E RPI 5.0FSN3E RPI 6.0FSN3E RPI 8.0FSN3E RPI 10.0FSN3E
Nominal Capacity (Min-Max) (kW)
Cooling 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0) 20.0 (9.0 ~ 22.4) 25.0 (11.2 ~ 28.0)
Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0) 16.0 (6.0 ~ 18.0) 22.4 (8.3 ~ 25.0) 28.0 (9.0 ~ 31.5)
UK Cooling Capacity (kW)
Total 5.3 5.9 7.5 10.6 13.1 15.6 18.0 22.0
Sensible 4.0 4.5 5.6 7.7 9.4 11.2 12.8 16.0
EER/COP Cooling 3.56 2.89 2.70 2.92 2.93 2.75 2.57 2.41
Heating 3.84 3.62 3.17 3.21 3.33 3.23 3.07 3.03
Energy LabelCooling A C D C C D E E
Heating A A D C C C D DIndoor Sound Pressure Level dB(A) SP-00 33/31/29 35/33/30 35/35/31 37/36/35 39/38/36 40/39/38 54/54/51 55/55/52
Indoor Fan (m³/min) SP-00 16/15/13 19/17/15 22/20/17 30/28/25 35/32/28 36/33/29 66/66/60 75/75/68.5
Static Pressure (Pa) SP-01/00/02 80/50/25 80/50/25 100/60/25 120/80/30 120/80/30 120/80/30 220/220/180 220/220/180
Dimensions (mm) & Weight (kg)
Height 275 275 423
Width 1084 1474 1592
Depth 600 600 600
Weight 35 37 37 49 49 49 85 87
Recommended Fuse Size (A) 5 5 5 5 5 5 10 10
Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E - -
Outdoor 3Ø - - - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E RAS 8.0HRNSE RAS 10.0HRNSE
Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 45 (43) 46 (44) 48 (46) 50 (48) 52 (50) 55 (53) 53 (51) 60 (56)
Heating 47 48 50 52 54 57 55 62
Dimensions (mm) & Weight (kg)
Length 600 800 1380
Width 792 950 950
Depth 300 370 370
Weight 42 / - 42 / - 44 / - 79 / 79 83 / 83 83 / 83 135 141
Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db
Heating (-10 ~ 15)wb (-10 ~ 15)wb
Refrigerant Piping (mm) (in)
Liquid 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)*
Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 28.6(1/8)* 28.6(1/8)*
Piping (m)
Length 50 50 30 50 50 50 50 50
Lift 30 30 30 30 30 30 30 30
Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 65g/m 30 / 120g/m
Power Supply1 Phase 1Ph 220-240V 50Hz - -
3 Phase - - - 3Ph 380-415 50Hz
Power To Outdoor
Interconnecting Cables No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)
Cooling 5.7 / - 8.6 / - 10.4 / - 16.1 / 4.9 17.6 / 6.2 21.1 / 7.5 - / 10.7 - / 14.6
Heating 5.9 / - 8.0 / - 10.5 / - 16.9 / 5.0 17.3 / 6.1 20.5 / 7.3 - / 9.9 - / 13.5
Recommended Fuse Size (A) (1Ø/3Ø) 16 / - 20 / - 20 / - 32 / 16 32 / 16 32 / 16 - / 25 - / 25
RAS-HVRNS2(E)
S Y S T E MFREE
hitachiaircon.com Email: [email protected]: 01628 585 394
* 3HP Std. Inverter Centrifugal
Utopia IVX
Outdoor Units
In the Ceiling (ducted)PC-ARTRPI-FSN3E
RPI 3.0FSN3E RPI 4.0FSN3E RPI 5.0FSN3E RPI 6.0FSN3E RPI 8.0FSN3E RPI 10.0FSN3E
Nominal Capacity (kW)Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0) 20.0 (9.0 ~ 22.4) 25.0 (11.2 ~ 28.0)
Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0) 16.0 (6.0 ~ 20.0) 22.4 (8.3 ~ 25.0) 28.0 (9.0 ~ 31.5)
UK Cooling Capacity (kW)Total 7.5 10.6 13.1 15.6 20.5 25.4
Sensible 5.6 7.7 9.4 11.2 15.8 20.1
EER/COP Cooling 3.55 3.72 3.50 3.16 2.84 2.72
Heating 3.86 4.17 3.76 3.62 3.51 3.34
Energy LabelCooling A A A B C D
Heating A A A A B C
Indoor Sound Pressure Level dB(A) SP-00 35/35/31 37/36/35 39/38/36 40/39/38 54/54/51 55/55/52
Indoor Fan (m3/min) SP-00 22/20/17 30/28/25 35/32/28 36/33/29 66/66/60 75/75/68.5
Static Pressure (Pa) SP-01/00/02 100/60/25 120/80/30 120/80/30 120/80/30 220/220/180 220/220/180
Dimensions (mm) & Weight (kg)
Height 275 275 423
Width 1084 1474 1592
Depth 600 600 600
Weight 37 49 49 49 85 87
Recommended Fuse Size (A) 5 5 5 5 10 10
Outdoor 1Ø RAS 3.0HVRNM2E
RAS 4.0HVRNM2E
RAS 5.0HVRNM2E
RAS 6.0HVRNM2E - -
Outdoor 3Ø - RAS 4.0HRNM2E
RAS 5.0HRNM2E
RAS 6.0HRNM2E
RAS 8.0HRNME
RAS 10.0HRNME
Outdoor Sound Pressure Level dB(A)
Cooling 47 (43) 49 (45) 51 (47) 51 (48) 52 (50) 55 (53)
Heating 49 51 53 53 54 57
Dimensions (mm) & Weight (kg)
Height 800 1380 1650
Width 950 950 1100
Depth 370 370 390
Weight 1Ø/3Ø 67 / - 98 / 98 105 / 105 105 / 105 - / 170 - / 170
Operating Range (ºC)Cooling (-10 ~ 46)db (-15 ~46)db
Heating (-20 ~ 15)wb (-20 ~15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)* 12.70(1/2)*
Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 28.6(1/8)* 28.6(1/8)*
Piping (m)
Length 50 70 75 75 100 100
Lift 30 30 30 30 30 30
Pre-charged 30 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 60g/m Calculate Calculate
Power Supply1 Phase 1Ph 220-240V 50Hz -
3 Phase - 3Ph 380-415V 50Hz
Power to Outdoor
Interconnecting Cables No. LNE + 2 Core screened
Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)Cooling 8.2 10.9 / 3.9 15.0 / 5.3 18.1 / 6.4 9.2 12.0
Heating 8.0 / - 10.7 / 3.8 14.5 / 5.1 18.2 / 6.4 - / 9.2 - / 12.3
Recommended Fuse Size (A) (1Ø/3Ø) 8.3 / - 10.7 / 3.8 15.2 / 5.4 18.1 / 6.4 - / 8.2 - / 11.1
RAS-HRNM(2)E
S Y S T E MFREE
Hitachi Product Catalogue | 31
RASC-HVRNE
Utopia IVX Centrifugal
Outdoor Units
In the Ceiling (ducted)
RPI 3.0FSN3E RPI 5.0FSN3E RPI 10.0FSN3E
Nominal Capacity (kW)Cooling 7.1 (3.4 ~ 8.0) 12.5 (4.7 ~ 14.0) 23.0 (10.3 ~ 25.0)
Heating 8.0 (3.4 ~ 9.0) 14.0 (5.0 ~ 16.0) 25.0 (9.4 ~ 26.0)
UK Cooling Capacity (kW)Total 7.4 12.6 22.0
Sensible 5.2 9.1 17.4
EER/COP Cooling 2.73 2.61 2.41
Heating 2.68 2.97 2.64
Energy LabelCooling D D E
Heating E D E
Indoor Sound Pressure Level dB(A) SP-00 35/35/31 39/38/36 55/55/52
Indoor Fan (m3/min) SP-00 22/20/17 35/32/28 75/75/68.5
Static Pressure (Pa) SP-01/00/02 100/60/25 120/80/30 220/220/180
Dimensions (mm) & Weight (kg)
Height 275 275 423
Width 1084 1474 1592
Depth 600 600 600
Weight 37 49 87
Recommended Fuse Size (A) 5 5 10
Outdoor 1Ø RASC 3.0HVRNE* RASC 5.0HVRNME -
Outdoor 3Ø - - RASC 10.0HRNME
Outdoor Sound Pressure Level dB(A)Cooling 46 55 68
Heating 46 56 68
Dimensions (mm) & Weight (kg)
Height 430 640
Width 1250 1850
Depth 1300 985
Weight 168 176 262
Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44 60 / 65/ 69 90 / 105 / 109
Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15 100 / 50 / 12 130 / 62 / 25
Operating Range (ºC)Cooling (-5 ~ 43)db (-5 ~ 46)db
Heating (-15 ~ 15)wb (-15 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 12.7 (1/2)
Gas 15.88(5/8) 15.88(5/8) 28.6(1/8)*
Piping (m)
Length 30 70 50
Lift 30 30 30
Pre-charged 20 / 60g/m 15 / 60g/m 7.5 / 120g/m
Power Supply1 Phase 1Ph 220-240V 50Hz -
3 Phase - 3Ph 380-415V 50Hz
Power to Outdoor
Interconnecting Cables No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)Cooling 11.3 / - 22 / - - / 20.1
Heating 11.9 / - 21.6 / - - / 20.2
Recommended Fuse Size (A) (1Ø/3Ø) 32 / - 40 / - - / 40
* 3HP Std. Inverter Centrifugal.
PC-ART RPI-FSN3E
S Y S T E MFREE
hitachiaircon.com Email: [email protected]: 01628 585 394
Ceiling Suspended
Features and Benefits
Utopia Ceiling Suspended
COP of 3.62 and EER of 3.32
An innovative fan and heat exchanger design led to the creation of today’s ultra slim ceiling unit. Fully adjustable mounting brackets allow the unit to be fitted flush with the ceiling
To expand the installation and positioning options the unit has a choice of two drain pipe connections, also refrigeration pipes can be connected to the left, right or rear of the unit
A highly efficient, multi blade centrifugal fan along with the automatic swing louvre generates a powerful and evenly distributed airflow ensuring comfort throughout the room
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
Hitachi Product Catalogue | 33
Product Summary Utopia ESRPC 2.0 ~ 6.0FSN2E
Utopia IVXRPC 3.0 ~ 6.0FSN2E
Utopia IVX Centrifugal*RPC 3.0 ~ 5.0FSN2E
Nominal Cooling Capacity (kW) 5.0 ~ 14.0 7.1 ~ 14.0 7.1 ~ 12.5
Nominal Heating Capacity (kW) 5.6 ~ 16.0 8.0 ~ 16.0 8.0 ~ 14.0
Refrigerant R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter
Operating Range1 (Cooling) (db) -10ºC / +43ºC -10ºC / +43ºC -5ºC / +46ºC
Operating Range (Heating) (wb) -10ºC / +15ºC (*) -15ºC / +15ºC -15ºC / +15ºC
Std. Remote Controller Type Wired or Infra Red Wired or Infra Red Wired or Infra Red
Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option
Condensate Pump No No No
¹ Selected Models (*) -15ºC 2.0/2.5 models * 3HP Std. Inverter Centrifugal
Outdoor UnitsRAS-H(V)RNM2E
Utopia ES
Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E
Outdoor 3Ø - - - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E
Outdoor Sound Pressure Level dB(A)
Cooling 45 (43) 46 (44) 48 (46) 50 (48) 52 (50) 55 (53)
Heating 47 48 50 52 54 57
Dimensions (mm) & Weight (kg)
Height 600 800
Width 792 950
Depth 300 370
Weight 1Ø/3Ø 42 / - 42 / - 44 / - 79 / 79 83 / 83 83 / 83
Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db
Heating (-10 ~ 15)wb (-10 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Piping (m)
Length 50 50 30 50 50 50
Lift 30 30 30 30 30 30
Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m 30 / 60g/m
Power Supply1 Phase 1Ph 220-240V 50Hz
3 Phase - - - 3Ph 380-415 50Hz
Power to Outdoor
Interconnecting Cables No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)Cooling 7.5 / - 9.9 / - 10.4 / - 16.1 / 5.7 18.8 / 6.6 24.8 / 8.8
Heating 8.5 / - 10.8 / - 10.5 / - 16.9 / 6.0 19.1 / 6.7 24.1 / 8.5
Recommended Fuse Size (A) (1Ø/3Ø) 16 / - 20 / - 20 / - 32 / 16 32 / 16 32 / 16
RPC 2.0FSN2E
RPC 2.5FSN2E RPC 3.0FSN2E RPC 4.0FSN2E RPC 5.0FSN2E RPC 6.0FSN2E
Nominal Capacity (Min-Max) (kW)
Cooling 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (1.5 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0)
Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (1.5 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0) 16.0 (6.0 ~ 18.0)
UK Cooling Capacity (kW)Total 5.3 5.9 7.5 10.6 13.1 15.6
Sensible 4.0 4.5 5.6 7.7 9.4 11.2
EER/COP Cooling 2.73 2.55 2.82 2.62 2.80 2.41
Heating 2.73 2.73 3.16 2.81 3.09 2.83
Energy LabelCooling D E C D D E
Heating E E D D D D
Indoor Sound Pressure Level dB(A) 44/42/38 46/43/41 48/45/42 49/45/39 49/46/41 50/48/44
Indoor Fan (m3/min) 15/13/10 18/16/12 21/17/15 30/24/19 35/28/21 37/32/27
Dimensions (mm) & Weight (kg)
Length 1094 1314 1314 1574
Width 625 625 625 625
Depth 163 163 225 225
Weight 28 31 31 35 41 41
Recommended Fuse Size (A) 5 5 5 5 5 5
Ceiling SuspendedRPC-FSN2E PC-ART
S Y S T E MFREE
Hitachi Product Catalogue | 35
Utopia IVX
RPC-FSN2E PC-ART
Ceiling Suspended
Outdoor UnitsRAS-HVRNS2(E)
RPC 3.0FSN2E RPC 4.0FSN2E RPC 5.0FSN2E RPC 6.0FSN2E
Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0)
Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0) 16.0 (6.0 ~ 20.0)
UK Cooling Capacity (kW)Total 7.8 10.5 13.1 15.7
Sensible 5.4 7.5 9.2 11.0
EER/COP Cooling 3.07 3.32 3.24 2.79
Heating 3.25 3.28 3.62 3.34
Energy LabelCooling B A A D
Heating C C A C
Indoor Sound Pressure Level dB(A) 48/45/42 49/45/39 49/46/41 50/48/44
Indoor Fan (m3/min) 21/17/15 30/24/19 35/28/21 37/32/27
Dimensions (mm) & Weight (kg)
Length 1314 1314 1574
Width 625 625 625
Depth 163 225 225
Weight 31 35 41 41
Recommended Fuse Size (A) 5 5 5 5
Outdoor 1Ø RAS 3.0HVRNM2E RAS 4.0HVRNM2E RAS 5.0HVRNM2E RAS 6.0HVRNM2E
Outdoor 3Ø - RAS 4.0HRNM2E RAS 5.0HRNM2E RAS 6.0HRNM2E
Outdoor Sound Pressure Level dB(A)Cooling 47 (43) 49 (45) 51 (47) 51 (48)
Heating 49 51 53 53
Dimensions (mm) & Weight (kg)
Height 800 1380
Width 950 950
Depth 370 370
Weight 1Ø/3Ø 67 / - 98 / 98 105 / 105 105 / 105
Operating Range (ºC)Cooling (-10 ~ 46)db
Heating (-20 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Piping (m)
Length 50 70 75 75
Lift 30 30 30 30
Pre-charged 30 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 60g/m
Power Supply1 Phase 1Ph 220-240V 50Hz
3 Phase - 3Ph 380-415V 50Hz
Power to Outdoor
Interconnecting Cables No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10 < 10 < 10
Running Current (1Ø/3Ø) (A)Cooling 9.5 / - 12.6 / 4.4 16.1 / 5.1 21.2 / 7.5
Heating 10.2 / - 14.4 / 5.1 16.1 / 5.4 20.2 / 7.2
Recommended Fuse Size (A) (1Ø/3Ø) 20 / - 32 / 16 32 / 16 32 / 16
S Y S T E MFREE
hitachiaircon.com Email: [email protected]: 01628 585 394
Utopia IVX Centrifugal
Outdoor Units
Ceiling SuspendedRPC-FSN2E PC-ART
RPC 3.0FSN2E RPC 5.0FSN2E
Nominal Capacity (Min-Max) (kW)Cooling 7.1 (1.5 ~ 8.0) 12.5 (4.7 ~ 14.0)
Heating 8.0 (1.5 ~ 9.0) 14.0 (5.0 ~ 16.0)
UK Cooling Capacity (kW)Total 7.6 13.1
Sensible 5.5 9.4
EER/COP Cooling 2.70 2.63
Heating 2.62 2.98
Energy LabelCooling D D
Heating E D
Indoor Sound Pressure Level dB(A) 48/45/42 49/46/41
Indoor Fan (m3/min) 21/17/15 35/28/21
Dimensions (mm) & Weight (kg)
Length 1314 1574
Width 625 625
Depth 163 225
Weight 31 41
Recommended Fuse Size (A) 5 5
RASC-HVRN(M)E
RASC 3.0HVRNE* RASC 5.0HVRNME
Outdoor Sound Pressure Level dB(A)
Cooling 46 55
Heating 46 56
Dimensions (mm) & Weight (kg)
Height 430
Width 1250
Depth 1300
Weight 168 176
Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44 60 / 65/ 69
Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15 100 / 50 / 12
Operating Range (ºC)Cooling (-5 ~ 46)db
Heating (-15 ~ 15)wb (-15 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8)
Gas 15.88(5/8) 15.88(5/8)
Piping (m)
Length 30 70
Lift 30 30
Pre-charged 20 / 60g/m 15 / 60g/m
Power Supply 1 Phase 1Ph 220-240V 50Hz
Power To Outdoor
Interconnecting Cables No. LNE + 2 Core Screened
Starting Current (A) < 10 < 10
Running Current (230v) (A)Cooling 11.3 22
Heating 11.9 21.6
Recommended Fuse Size (A) 32 40
* 3HP Std. Inverter Centrifugal
S Y S T E MFREE
Hitachi Utopia IVX Centrifugal
Can be installed inside where circumstances or planning regulations restrict the use of traditional-style outdoor units
Contact [email protected] find out more
Hitachi Price List | 37
Features and Benefits
Floor Mounted
All RAC Floor Mounted
ambient temperature
Optional simplified hard wired or infra red remote controller with 7 day timer
Compatible with H-LINK II Control and CS Net Web controls that integrate with all leading BMS protocols.
RAC Shirokuma Floor Mounted
Units are available in a variety of colours to compliment any interior
The unit comes with a removable stand which gives the option of mounting it on the wall.
RAC NX2 Floor Mounted
Utopia Floor Mounted
The space saving design (620mm in height, 220mm in depth), fits perfectly into the space below bay windows and allows the unit to be freely installed without spoiling the aesthetics of a room
It is also possible to conceal the remote controller as there is space to install a PC-ART inside the casing
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
Hitachi Product Catalogue | 39
Product Summary
Shirokuma NX2 Standard Utopia ES
RAF 25 ~ 50FX8 RAF 25 ~ 50NX2 Floor Mounted uncasedRPFI 2.0 ~ 2.5FSN2E
Floor Mounted casedRPF 2.0 ~ 2.5FSN2E
Nominal Cooling Capacity (kW) 2.5 ~ 5.0 2.5 ~ 5.0 5.0 ~ 6.3 5.0 ~ 6.3
Nominal Heating Capacity (kW) 3.4 ~ 6.5 3.4 ~ 6.0 5.6 ~ 7.0 5.6 ~ 7.0
Refrigerant R410A R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter
Operating Range1 (Cooling) (db) -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC
Operating Range (Heating) (wb) -15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC
Std. Remote Controller Type Infra Red Infra Red Wired or Infra Red Wired or Infra Red
Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option
Condensate Pump No No No No
¹ Selected Models
Outdoor Units
Floor Mounted
RAC Shirokuma
RAF 25FX8 (W/B) RAF 35FX8 (W/B) RAF 50FX8 (W/B)
Nominal Capacity (Min ~ Max) (kW)Cooling 2.5 (0.9~3.1) 3.5 (0.9~4.0) 5.0 (0.9~5.2)
Heating 3.4 (0.9~4.4) 4.2 (0.9~5.0) 6.5 (0.9~8.1)
UK Cooling Capacity (kW)Total 2.4 3.1 4.2
Sensible 1.9 2.5 3.1
EER/COPCooling 4.31 3.43 3.21
Heating 4.30 3.69 3.65
Energy LabelCooling A A A
Heating A A A
Indoor Sound Pressure Level dB(A)Cooling 38/31/26/20 39/31/26/20 43/36/29/22
Heating 38/31/27/23 39/31/26/20 44/36/29/22
Indoor Fan (m3/min)Cooling 10.5/8.5/6.5/4.5 10.5/8.5/6.5/4.5 11.5/9.0/7.5/5.0
Heating 11.0/9.0/7.0/5.0 11.0/9.0/7.0/5.0 12.0/9.5/8.0/5.5
Dimensions (mm) & Weight (kg)
Height 590
Width 750
Depth 215
Weight 15
RAC 25FX8 RAC 35FX8 RAC 50FX8
Outdoor Sound Pressure Level dB(A)Cooling 45 46 50
Heating 47 48 52
Dimensions (mm) & Weight (kg)
Height 548 600
Width 750 792
Depth 288 299
Weight 35 42
Operating Range (ºC)Cooling -10 ~ +43
Heating -15 ~ +21
Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)
Piping (m)
Length 20 30
Lift 10 10
Pre-charged 20 30
Power Supply 230V 1ph 50Hz
Power to Outdoor
Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened
Starting Current (A) 4.0 5.8 8.2
Running Current (230v) (A)Cooling 2.97 4.67 6.85
Heating 3.82 5.58 7.82
Recommended Fuse Size (A) 16 16 16
RAF-FX8 RAR-3U2
RAC-FX8
Hitachi Product Catalogue | 41
RAC NX2
Outdoor Units
Floor Mounted
For RAC accessories see page 49
RAF 25NX2 RAF 35NX2 RAF 50NX2
Nominal Capacity (Min ~ Max) (kW)Cooling 2.5 (0.9-3.1) 3.5 (0.9-4.0) 5.0 (0.9-5.2)
Heating 3.4 (0.9-4.4) 4.2 (0.9-5.0) 6.0 (0.9-7.3)
UK Cooling Capacity (kW)Total 2.1 2.9 4.2
Sensible 1.9 2.5 3.2
EER/COPCooling 3.57 3.21 3.21
Heating 3.86 3.78 3.61
Energy LabelCooling A A A
Heating A A A
Indoor Sound Pressure Level dB(A)Cooling 38/32/26/20 40/32/27/22 44/37/29/26
Heating 38/32/26/20 39/32/26/23 44/37/29/25
Indoor Fan (m3/min)Cooling 9.0/7.7/6.3/5.0 10.0/8.3/6.8/5.5 10.8/8.8/7.2/6.2
Heating 10.0/8.3/6.8/5.3 10.8/9.0/7.3/5.8 12.0/9.5/7.8/6.7
Dimensions (mm) & Weight (kg)
Height 600
Width 760
Depth 235
Weight 14
RAC 25NX2 RAC 35NX2 RAC 50NX2
Outdoor Sound Pressure Level dB(A)Cooling 46 47 52
Heating 48 49 52
Dimensions (mm) & Weight (kg)
Height 505 548 600
Width 700 750 792
Depth 258 288 299
Weight 27 35 40
Operating Range (ºC)Cooling -10 ~ +43
Heating -15 ~ +21
Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)
Piping (m)
Length 20
Lift 10
Pre-charged 20
Power Supply 230V 1ph 50Hz
Power to Outdoor
Interconnecting Cables No. 2 Core Screened
Starting Current (A) 4.0 5.8 8.2
Running Current (230v) (A)Cooling 2.97 4.67 6.85
Heating 3.82 5.58 7.82
Recommended Fuse Size (A) 16 16 16
RAF-NX2
RAC-NX2
hitachiaircon.com Email: [email protected]: 01628 585 394
RPFI-FSN2ERPF-FSN2E PC-ART
RAS-HVRN2
Floor Uncased and Floor CasedRPFI 2.0FSN2E
UncasedRPF 2.0FSN2E
CasedRPFI 2.5FSN2E
UncasedRPF 2.5FSN2E
Cased
Nominal Capacity (Min ~ Max) (kW)Cooling 5.0 (2.2 ~ 5.6) 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 6.0 (2.2 ~ 6.3)
Heating 5.6 (2.2 ~ 7.1) 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1)
UK Cooling Capacity (kW)Total 5.3 5.3 5.9 5.9
Sensible 3.9 3.9 4.3 4.3
EER/COPCooling 3.11 3.11 2.64 2.64
Heating 3.18 3.18 2.84 2.84
Energy LabelCooling B B D D
Heating D D D D
Sound Pressure Level dB(A) 39/36/32 32/36/39 42/38/34 34/38/42
Indoor Fan (m3/min) 16/14/11 11/14/16 16/14/11 11/14/16
Dimensions (mm) & Weight (kg)
Length 620 630 620 630
Width 1223 1420 1223 1420
Depth 220 220 220 220
Weight 27 33 28 34
Recommended Fuse Size (A) 5 5 5 5
RAS 2.0HVRN2 RAS 2.5HVRN2
Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 45 (43) 46 (44)
Heating 47 48
Dimensions (mm) & Weight (kg)
Height 600 600
Width 792 792
Depth 300 300
Weight 42 42
Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db
Heating (-10 ~ 15)wb (-10 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 6.35(1/4) 6.35(1/4)
Gas 12.7(1/2) 12.7(1/2)
Piping (m)
Length 50 50
Lift 30 30
Pre-charged 30 / 30g/m 30 / 30g/m
Power Supply 1Ph 220-240V 50Hz 1Ph 220-240V 50Hz
Power to Outdoor Outdoor
Interconnecting Cables No. LNE + 2 Core Screened LNE + 2 Core Screened
Starting Current (A) < 10 < 10
Running current (A)Cooling 6.7 9.7
Heating 7.4 10.5
Recommended Fuse Size (A) 16 20
Utopia ES
Outdoor Units
Floor Mounted
S Y S T E MFREE
Hitachi NX2
With A/A energy rating and capacities from 2.5kW to 6.0kW, the NX2 floor mount can be installed with RAC Multizone
product ranges for total comfort
Contact [email protected] to find out more
Hitachi Product Catalogue | 43
Features and Benefits
Multizone Multi Split systems
The Hitachi Multizone range was the world’s
first all-DC Inverter Multisplit system with zone
by zone cooling or heating for up to six rooms.
Hitachi DC scroll and DC twin-rotary compressor,
together with award-winning DC inverter PAM
technology, aid the achievement of a system
power factor of almost 100%, thus providing
unparalleled performance and efficiency.
RAC Multizone
COP of 4.34 and EER of 4.47
A washable carbon and anti-bacteria air purifying filter ensures that the micro dust, pollen particles and odours that can collect on filters can be easily removed
Compatibility between product ranges of outdoor and indoor units
The wide range of units have been designed for cooling operation under low temperatures, down to -10°C. This feature enables cooling to be obtained even in winter on buildings with high internal heat gains due to lighting, people and machines, particularly in areas such as shops and lecture rooms. The heating operation under low temperature, down to -15°C can also be performed
Infra red remote controller with 24hr timer, simplified hard wired controller or hard wired remote controller with built in 7 day timer
Compatible with H-LINK Control/Ready to Connect to PCS-6RAD Adapter.
Hitachi Product Catalogue | 45
Product Summary RAM 35QH52 Rooms
RAM 52QH52 Rooms
RAM 53QH53 Rooms
RAM 71QH54 Rooms
RAM 90QH55 Rooms
RAM 130QH56 Rooms
Nominal Cooling Capacity (kW) 3.5 (1.5-4.0)
5.2 (1.5-6.6)
5.2 (1.5-6.6)
7.1 (2.4-8.8)
9.0 (1.5-9.5)
12.6 (1.5-13.2)
Nominal Heating Capacity (kW) 4.2 (1.5-5.0)
6.8 (1.5-7.2)
6.8 (1.5-7.2)
8.6 (2.6-9.5)
11.0 (1.5-11.5)
14.4 (1.5-14.4)
Refrigerant R410A R410A R410A R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter
Operating Range (Cooling) (db) -10ºC / +43ºC
Operating Range (Heating) (wb) -15ºC / +21ºC
Remote Controller Type Hard Wired or Infra Red
Remote Control Timer 24hr or 7 Day option
Outdoor Units
For full technical details, refer to Technical Manual
RAM 35QH5 RAM 52QH5 RAM 53QH5 RAM 71QH5 RAM 90QH5 RAM 130QH5
Nominal Capacity (Min-Max) (kW) Cooling 3.5 (1.5 - 4.0) 5.2 (1.5 - 6.6) 5.2 (1.5 - 6.6) 7.1 (2.4 - 8.8) 9.0 (1.5 - 9.5) 12.6 (1.50 - 13.20)Heating 4.2 (1.5 - 5.0) 6.8 (1.5 - 7.2) 6.8 (1.5 - 7.2) 8.6 (2.8 - 9.5) 11.0 (1.5 - 11.5) 14.4 (1.50 - 14.40)
EER/COP Cooling 3.72 3.47 3.41 3.32 3.81 3.01Heating 4.94 3.79 4.03 4.03 4.47 3.79
Energy LabelCooling A A A A A BHeating A A A A A A
Maximum Indoor Units 2 2 3 4 5 1, 2, 3 4, 5, 6Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 49(43) 52(45) 52(45) 53(43) 55(46) 55(48)Heating 51(44) 53(45) 53(45) 56(43) 58(52) 56(48)
Dimensions (mm) & Weight (kg)
Height 570 650 650 800 800 1450Width 750 850 850 850 950 855Depth 280 298 298 298 370 308Weight 40 50 50 55 71 113
Operating Range (ºC)Cooling -10ºC / 43ºC (db)Heating -15ºC / 21ºC (wb)
Power Supply AC 1Ph 220-230V 50HzPower To OutdoorInterconnecting Cables No. / Indoors 2 Core ScreenedStarting Current (A) 5.8 11 11 14.5 16 20
Running Current (230v) (A)Cooling 5.7 6.6 6.7 9.4 10.8 19.2Heating 6.2 7.9 7.4 9.6 11.3 17.4
Recommended Fuse Size (A) 16 16 16 30 30 30
At least two indoor units should be connected (RAM-90QH5)At least four indoor units should be connected (RAM-130QH5)
RAM-QH5
RAC Multi Split Systems
Indoor Units
Hitachi Product Catalogue | 47
RAC Multi Split Systems
For full technical details, refer to Technical Manual
RAK-QH8(S)
Indoor Unit RAK 18QH8S (W/B)* RAK 25QH8 (W/B) RAK 35QH8 (W/B) RAK 50QH8 (W/B)
Nominal Cooling (kW) 2.0 2.5 3.5 5.0
Nominal Heating (kW) 2.5 3.6 4.5 6.7
Indoor Unit RAI - 25NH5A RAI - 35NH5A RAI - 50NH5A
Nominal Cooling (kW) 2.5 3.5 5.0
Nominal Heating (kW) 3.6 4.5 6.7
RAF-QH8
Indoor Unit RAF 25QH8 (W/B) RAF 35QH8 (W/B) RAF 50QH8 (W/B)
Nominal Cooling (kW) 2.5 3.5 5.0
Nominal Heating (kW) 3.6 4.5 6.7
Indoor Unit RAF - 25NX2 RAF - 35NX2 RAF - 50NX2
Nominal Cooling (kW) 2.5 3.5 5.0
Nominal Heating (kW) 3.6 4.5 6.7
* RAK 18QHS8 can be DIP switched to size 12
RAI-NH5ARAI
RAD-NH7A
Indoor Unit RAD - 18NH7A RAD - 25NH7A RAD - 35NH7A RAD - 50NH7A
Nominal Cooling (kW) 2.0 2.5 3.5 5.0
Nominal Heating (kW) 2.5 3.6 4.5 6.7
RAF-NX2
hitachiaircon.com Email: [email protected]: 01628 585 394
Combinations
For full technical details, refer to Technical ManualFurther Control options available see page 86
RAM 35QH52 Indoor UnitsNo.1 No.212 12 ~ 3518 18 ~ 3525 25 ~ 35
RAM 52QH52 Indoor UnitsNo.1 No.212 12 ~ 5018 18 ~ 5025 25 ~ 5035 35 ~ 50
RAM 53QH52 Indoor Units 3 Indoor UnitsNo.1 No.2 No.1 No.2 No.312 12 ~ 50 12 12 12 ~ 5018 18 ~ 50 12 18 18 ~ 5025 25 ~ 50 12 25 25 ~ 3535 35 ~ 50 12 35 35
18 18 18 ~ 5018 25 25 ~ 3518 35 3525 25 25 ~ 35
RAM 71QH52 Indoor Units 3 Indoor Units 4 Indoor UnitsNo.1 No.2 No.1 No.2 No.3 No.1 No.2 No.3 No.4
12 12 ~ 50 12 12 12 ~ 50 12 12 12 12 ~ 5018 18 ~ 50 12 18 18 ~ 50 12 12 18 18 ~ 5025 25 ~ 50 12 25 25 ~ 50 12 12 25 25 ~ 5035 35 ~ 50 12 35 35 ~ 50 12 12 35 35 ~ 5050 50 12 50 50 12 18 18 18 ~ 50
18 18 18 ~ 50 12 18 25 25 ~ 5018 25 25 ~ 50 12 18 35 3518 35 35 ~ 50 12 25 25 25 ~ 3525 25 25 ~ 50 12 25 35 3525 35 35 ~ 50 18 18 18 18 ~ 5035 35 35 18 18 25 25 ~ 35
18 18 35 3518 25 25 25 ~ 3525 25 25 25 ~ 35
Minimum of 2 indoor units must be connected.Single unit operation possible.
RAM 90QH52 Indoor Units 3 Indoor Units 4 Indoor Units 5 Indoor UnitsNo.1 No.2 No.1 No.2 No.3 No.1 No.2 No.3 No.4 No.1 No.2 No.3 No.4 No.518 18~50 18 18 18~50 18 18 18 18~50 18 18 18 18 18~5025 25~50 18 25 25~50 18 18 25 25~50 18 18 18 25 25~5035 35~50 18 35 35~50 18 18 35 35~50 18 18 18 35 35~5050 50 18 50 50 18 18 50 50 18 18 18 50 50
25 25 25~50 18 25 25 25~50 18 18 25 25 25~5025 35 35~50 18 25 35 35~50 18 18 25 35 35~5025 50 50 18 25 50 50 18 18 35 35 3535 35 35~50 18 35 35 35~50 18 25 25 25 25~5035 50 50 18 35 50 50 18 25 25 35 35~5050 50 50 25 25 25 25~50 18 25 35 35 35
25 25 35 35~50 25 25 25 25 25~5025 25 50 50 25 25 25 35 3525 35 35 35~50 25 25 35 35 3535 35 35 35~50 - - - - -
RAC Multi Split Systems
Hitachi Product Catalogue | 49
Combinations
Model Code
SPX-RCK3 Wired Remote Controller - WX8, FH6, FH7, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8
SPX-RCK2 Wireless Remote Controller & Receiver Kit - RAD-NH7A
SPX-WKT1 Wired Remote Controller + 7 Day Timer - WX8, FH6, FH7, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8
SPX-DST1 Optional Distributor Kit for SPK-WKT1
SPX-WDST8M Optional wiring kit for SPX-WKT1 & SPX-DST1
PSC-6RAD H-LINK Adapter - WX8, FH6, FH7, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8
RAC Accessories
ModelL TOTAL L MIN L MAX H MAX H INDOOR Piping Pre-charged
(m) (m) (m) (m) (m) Liq. (mm) (in) Gas (mm) (in) (m) / (g/m)RAM 35QH5 35 5 25 20 5 6.35(1/4) x 2 9.52(3/8) x 2 35 / -RAM 52QH5 35 5 25 20 5 6.35(1/4) x 2 9.52(3/8) x 2 35 / -RAM 53QH5 45 5 25 20 5 6.35(1/4) x 3 9.52(3/8) x 3 35 / 20g/mRAM 71QH5 60 5 25 20 5 6.35(1/4) x 4 9.52(3/8) x 4 30 / 20g/mRAM 90QH5 75 5 25 20 5 6.35(1/4) x 5 9.52(3/8) x 5 30 / 15g/m
RAM 130QH5
L145 5
2520 5 6.35(1/4) x 3 9.52(3/8) x 3 35 / 20g/mL2 L2 + L3 <35L3
L445 5
2520 5 6.35(1/4) x 3 9.52(3/8) x 3 35 / 20g/mL5 L5 + L6 <35L6
MIN MAX
MAX INDOOR
RAM 130QH54 Indoor Units 5 Indoor Units 6 Indoor Units
Circuit 1 Circuit 2 Circuit 1 Circuit 2 Circuit 1 Circuit 2No.1 No.2 No.3 No.4 No.1 No.2 No.3 No.4 No.5 No.1 No.2 No.3 No.4 No.5 No.618 18~50 18 18~50 18 18~50 18 18 18~50 18 18 18~50 18 18 18~5018 25~50 18 25~50 18 18~50 18 25 25~35 18 18 18~50 18 25 25~3518 35~50 35 35~50 18 18~50 18 35 35 18 18 18~50 18 35 3525 25~50 25 25~50 18 18~50 25 25 25~35 18 18 18~50 25 25 25~3535 35~50 35 35~50 25 25~50 18 18 18~50 18 25 25~35 18 18 18~50
25 25~50 18 25 25~35 18 25 25~35 18 25 25~3525 25~50 18 35 35 18 25 25~35 18 35 3525 25~50 25 25 25~35 18 25 25~35 25 25 25~3535 35~50 18 18 18~50 18 35 35 18 18 18~5035 35~50 18 25 25~35 18 35 35 18 25 25~3535 35~50 18 35 35 18 35 35 18 35 3535 35~50 25 25 25~35 18 35 35 25 25 25~35
25 25 25~35 18 18 18~5025 25 25~35 18 25 25~3525 25 25~35 18 35 3525 25 25~35 25 25 25~35
For full technical details, refer to Technical Manual
RAC Multi Split Systems
hitachiaircon.com Email: [email protected]: 01628 585 394
Features and Benefits
Twin, Triple and Quad Splits Utopia ES, Centrifugal and IVX Systems
Utopia ES
The ‘ES’ range is small and compact; the units have only one fan (7.0 kW — 16kW models)
Common cabinet size and exterior of the Utopia ES and Utopia IVX allows for the units to be installed together creating a uniform appearance
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
Utopia IVX Centrifugal
Hitachi’s range of Utopia Centrifugal units can be installed indoors with field supplied ductwork and are therefore ideal for situations where installations have to be hidden or where circumstances do not allow for the use of traditional styled outdoor units
Low temperature operations
Wide working range including outdoor unit fan control in cooling mode for operating at low ambient temperature as standard (-5ºC to 43ºC cooling)
Compatible with all Hitachi System Free indoor units
Individual indoor unit control with an increased number of twins, triple and quad combinations
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols
H-LINK wiring system requires only two transmission wires connecting each indoor unit and outdoor unit for up to 16 refrigerant cycles, and connecting wires for all indoor units and all outdoor units in series.
Hitachi Product Catalogue | 51
Product SummaryUtopia ES Utopia IVX System Utopia Centrifugal
Twin, Triple & Quad Splits Twin, Triple & Quad Splits Twin, Triple & Quad Splits
Nominal Cooling Capacity (kW) 7.1 ~ 25.0 7.1 ~ 30.0 7.1 ~ 25.0
Nominal Heating Capacity (kW) 8.0 ~ 28.0 8.0 ~ 33.5 8.0 ~ 28.0
Refrigerant R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter
Operating Range (Cooling) (db) -10ºC / +43ºC (-15ºC ~ +46ºC) db (*) -5ºC / +43ºC
Operating Range (Heating) (wb) -15ºC / +15ºC (-20ºC / +15ºC) wb -15ºC / +15ºC
Indoor Unit Type All System Free Indoor units (inc mixed Indoor units on a system)
Remote Controller Type Wired or Infra Red
Remote Control Timer 24hr or 7 Day option
Condenser Air Direction - - Adjustable
(*) -5 3.0~6.0 models
Utopia IVX
The Utopia IVX is a very efficient product and is a further development on its predecessor which was presented the “Shoeene Taishou” (Energy Efficiency Award) by the Japanese Government
COP of 4.10 and EER of 3.90
The optimised refrigerant circuit increases seasonal COP for heating and seasonal EER for cooling by 4%
The unit uses a horizontal discharge twin fan design allowing for a more efficient use of floor space
Individual indoor unit control with an increased number of twins, triple and quad combinations (90-115% diversity - 4, 5 and 6HP models)
Common cabinet size and exterior of the IVX and Utopia ES allows for the units to be installed together creating a uniform appearance
The Utopia IVX changes the way we think about twin, triple and quad split configurations and is the perfect choice for installations requiring individual unit control but have no need for the piping length capabilities available with more expensive VRF systems
By the use of individual control we can create a more comfortable environment for rooms that have unbalanced loads. This also leads to more economical operation as units not requiring operation will stop, reducing wasted energy
7 day timer
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web
Optional integration with all leading BMS protocols.
High-load Area Low-load Area
Indoor Temperature24°C
Set Temp.24°C
Continued Operation Stopped
Comfortable ComfortableIVX SYSTEM
Comfortable
Indoor Temperature25°C
RAS-H(V)RNM2E RAS-H(V)RNM2E RAS-HRNM
Utopia IVXOutdoor 1Ø RAS 3.0HVRNM2E RAS 4.0HVRNM2E RAS 5.0HVRNM2E RAS 6.0HVRNM2E
Outdoor 3Ø - RAS 4.0HRNM2E RAS 5.0HRNM2E RAS 6.0HRNM2E
Possible Combinations
Single 3.0 - 4.0 - 5.0 - 6.0 -
Twin 1.5 1.5 Connected Capacity 90% ~ 115% (3.6 ~ 4.6HP)
Connected Capacity 90% ~ 115% (4.5 ~ 5.8HP)
Connected Capacity 90% ~ 115% (5.4 ~ 6.9HP)Triple -
Quad - Min Indoor Capacity 0.8HP Min Indoor Capacity 0.8HP Min Indoor Capacity 0.8HP
Utopia IVX RAS 8.0HRNM RAS 10.0HRNM RAS 12.0HRNM
Possible Combinations
Single 8.0 - - - 10.0 - - - - - - -
Twin4.0 4.0 - - 6.0 4.0 - - 6.0 6.0 - -
5.0 3.0 - - 5.0 5.0 - - - - - -
Triple
3.0 3.0 3.0 - 3.0 3.0 3.0 - 4.0 4.0 4.0 -
3.0 3.0 2.5 - 4.0 3.0 3.0 - -
3.0 2.5 2.5 - - -
3.0 3.0 2.3 - - -
Quad
2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0
2.5 2.5 2.0 2.0 3.0 3.0 2.5 2.0 4.0 3.0 3.0 2.5
2.5 2.0 2.0 2.0 3.0 2.5 2.5 2.5 4.0 3.0 2.5 2.5
2.5 2.5 1.8 1.8 3.0 3.0 2.0 2.0 3.0 3.0 3.0 2.5
2.5 2.3 1.8 1.8 3.0 2.5 2.5 2.0 3.0 3.0 2.5 2.5
2.5 2.0 2.0 1.8 3.0 3.0 2.3 2.3 4.0 4.0 2.3 2.3
2.3 2.3 1.8 1.8 3.0 3.0 2.3 2.0 4.0 3.0 3.0 2.3
2.3 2.0 2.0 1.8 3.0 2.5 2.5 2.3 4.0 3.0 2.5 2.3
Twin, Triple and Quad Splits | ES
Utopia Split Systems
Utopia ESOutdoor 1Ø RAS 3.0HVRNS2 RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E - -
Outdoor 3Ø - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E RAS 8.0HRNSE RAS 10.0HRNSE
Possible Combinations
Single 3.0 - 4.0 - 5.0 - 6.0 - - 8.0 - 10.0 -
Twin
1.5 1.5 2.0 2.0 2.5 2.5 3.0 3.0 - 4.0 4.0 5.0 5.0
- 2.0 2.0 2.5 2.5 3.0 2.5 - -
- 2.3 2.0 3.0 2.3 - -
- 2.5 1.8 3.0 1.8 - -
Triple
- 2.5 2.0 1.8 1.8 1.8 3.0 3.0 3.0 - -
- - - 2.0 2.0 2.0 - -
- - - 2.0 2.0 1.8 - -
- - - 2.0 1.8 1.8 - -
- - - 2.5 1.5 1.5 - -
Quad - - - 2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5
RAS-HVRNS2 RAS-HVRNS2E RAS-HRNSE
Twin, Triple and Quad Splits | IVX
For full technical details, refer to Technical Manual.Please refer to individual product pages for dimensional data.
Hitachi Product Catalogue | 53
Utopia Split Systems
Twin, Triple and Quad Splits | IVX CentrifugalRASC-H(V)RN(M)E
Utopia Centrifugal
Outdoor 1Ø RASC 3.0HVRNE RASC 5.0HVRNME -
Outdoor 3Ø - - RASC 10.0HRNME
Possible Combinations
Single 3.0 - 5.0 - - - 10.0 -
Twin1.5 1.5 2.5 2.5 - - 6.0 4.0
- 3.0 2.3 - - 5.0 5.0- - - - - 8.0 2.0
Triple- 1.8 1.8 1.5 - 3.0 3.0 3.0 -
- - 4.0 3.0 3.0 -
Quad
- - 2.5 2.5 2.5 2.5
- - 3.0 3.0 2.5 2.0
- - 3.0 2.5 2.5 2.5
- - 3.0 3.0 2.0 2.0
- - 3.0 2.5 2.5 2.0
- - 3.0 3.0 2.3 2.3
- - 3.0 3.0 2.3 2.0
- - 3.0 2.5 2.5 2.3
* 3HP Std. Inverter Centrifugal
For full technical details, refer to Technical Manual.Please refer to individual product pages for dimensional data.
hitachiaircon.com Email: [email protected]: 01628 585 394
System Free Indoor Units
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0Size 20 25 - 35 42 50 60 - 71 100
Wall Mounted RPK-FSN2MNominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3 7.1 10.0Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0 8.0 11.2UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9 7.5 10.6UK Sensible Cooling (kW) 1.5 1.9 2.3 2.7 3.1 3.8 4.1 4.4 5.6 7.5
RPK-FSN2M
Twin, Triple and Quad Splits
RCD-FSN2
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0Size 20 25 - 35 42 50 60 - 71 100 125
2-Way Cassette RCD-FSN2(including grille) Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3 7.1 10.0 12.5
Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0 8.0 11.2 14.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9 7.5 10.6 13.1UK Sensible Cooling (kW) 1.7 2.1 2.3 2.7 3.2 4.0 4.1 4.4 5.6 7.7 9.0
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0Size 20 25 - 35 42 50 60 - 71 100 125 140
4-Way Cassette RCI-FSN3E(including grille) Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3 7.1 10.0 12.5 14.0
Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0 8.0 11.2 14.0 16.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9 7.5 10.6 13.1 15.6UK Sensible Cooling (kW) 1.7 2.1 2.5 2.8 3.4 4.1 4.0 4.3 5.9 8.3 9.7 11.4
HP 0.8 1.0 1.3 1.5 1.8 2.0Size 20 25 - 35 42 50
Mini 4-Way Cassette
RCIM-FSN2Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0
(including grille) Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3UK Sensible Cooling (kW) 1.6 1.9 2.4 2.7 3.1 3.8
RCIM-FSN2
RCI-FSN3E
S Y S T E MFREE
Capacity achieved via dip switch setting capacity range (HP) Model allows dipswitch adjustment+
For full technical details, refer to Technical Manual. Please refer to individual product pages for dimensional data.
Hitachi Product Catalogue | 55
RPIM-FSN2E RPI-FSN2E
HP 0.8 1.0 1.3 1.5Size 20 25 - 35
Mini In the Ceiling RPIM-FSN2E
(Slim Width) Nominal Cooling (kW) 1.9 2.5 3.0 3.6Nominal Heating (kW) 2.2 2.8 3.4 4.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7UK Sensible Cooling (kW) 1.7 2.1 2.3 2.6
HP 0.8 1.0 1.3 1.5Size 20 25 - 35
In the Ceiling RPI-FSN2E
(Low Height) Nominal Cooling (kW) 1.9 2.5 3.0 3.6Nominal Heating (kW) 2.2 2.8 3.4 4.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7UK Sensible Cooling (kW) 1.7 2.1 2.3 2.7
HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0Size 42 50 60 - 71 100 125 140
Ceiling RPC-FSN2ESuspended Nominal Cooling (kW) 4.4 5.0 5.7 6.3 7.1 10.0 12.5 14.0
Nominal Heating (kW) 5.0 5.6 6.4 7.0 8.0 11.2 14.0 16.0UK Total Cooling (kW) 4.3 5.3 5.5 5.9 7.5 10.6 13.1 15.6UK Sensible Cooling (kW) 3.1 3.8 4.0 4.2 5.4 7.6 9.4 11.2
RPC-FSN2E
HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0 8.0 10.0Size 42 50 60 - 71 100 125 140 200 250
In the Ceiling RPI-FSN3E(Standard) Nominal Cooling (kW) 4.4 5.0 5.7 6.3 7.1 10.0 12.5 14.0 20.0 25.0
Nominal Heating (kW) 5.0 5.6 6.4 7.0 8.0 11.2 14.0 16.0 22.4 28.0UK Total Cooling (kW) 4.3 5.3 5.5 5.9 7.5 10.6 13.1 15.6 18.0 22.0UK Sensible Cooling (kW) 3.3 4.0 4.2 4.5 5.6 7.7 9.4 11.2 13.9 17.4
RPI-FSN3E
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 - 35 42 50 60 -
Floor Mounted RPFI-FSN2EUncased Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3
Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9UK Sensible Cooling (kW) 1.5 1.9 2.3 2.7 3.1 3.9 4.0 4.3
RPFI-FSN2E
System Free Indoor Units
Twin, Triple and Quad SplitsS Y S T E MFREE
Capacity achieved via dip switch setting capacity range (HP) Model allows dipswitch adjustment+
For full technical details, refer to Technical Manual. Please refer to individual product pages for dimensional data.
hitachiaircon.com Email: [email protected]: 01628 585 394
Model Description
PC-ART Standard Wired Remote Controller (inc. 7 Day Time Clock)
PC-ARF Wired LED Controller with advanced graphical interface (inc 7 Day Time Clock)
PC-ARH Simple Wired Remote Controller
PC-LH3A Wireless Remote Controller (Receiver kit required inc. with RPK-FSN2M)
PC-ALHN Receiver Kit panel mounted (RCI-FSN3E)
PC-ALHD Receiver Kit panel mounted (RCD-FSN2)
PC-ALHC Receiver Kit panel mounted (RCIM-FSN2)
PC-ALHZ Receiver Kit wall mounted (All System Free Indoor Units)
TE-03N Twin Pipe Kit (3HP System)
TE-04N Twin Pipe Kit (4HP System)
TE-56N Twin Pipe Kit (5 & 6HP System)
TE-08N Twin Pipe Kit (8HP System)
TE-10N Twin Pipe Kit (10 & 12HP System)
TRE-06N Triple Pipe Kit (4 ~ 6HP System)
TRE-810N Triple Pipe Kit (8 ~ 12HP System)
QE-810N Quad Pipe Kit (8 ~ 12HP System)
E-102SN2 Piping Kit (Only use with 8 ~ 12HP Utopia IVX)
E-162SN2 Piping Kit (Only use with 8 ~ 12HP Utopia IVX)
RPF-FSN2E
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 - 35 42 50 60 -
Floor Standard RPF-FSN2ECased Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3
Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9UK Sensible Cooling (kW) 1.5 1.9 2.3 2.7 3.1 3.9 4.0 4.3
System Free Indoor Units
Twin, Triple and Quad Splits
System Free Accessories
For full technical details, refer to Technical Manual.For centralised controllers and BMS interfaces see page 88
S Y S T E MFREE
Capacity achieved via dip switch setting capacity range (HP) Model allows dipswitch adjustment+
For full technical details, refer to Technical Manual. Please refer to individual product pages for dimensional data.
Hitachi Product Catalogue | 57
Utopia AHU Interface
Control Box EXV-2.0E1* EXV-2.5E1* EXV-3.0E1* EXV-4.0E1* EXV-5.0E1* EXV-6.0E1* EXV-8.0E1* EXV-10.0E1*
Dimensions (mm) & Weight (kg)
Height 291
Width 241
Depth 87
Weight 3.2 3.5
Power Supply 1 Phase 1Ph 220-240V 50Hz
Allowed Fan Current (A) 2.5 15
Expansion Valve Box EXV-2.0E1* EXV-2.5E1* EXV-3.0E1* EXV-4.0E1* EXV-5.0E1* EXV-6.0E1* EXV-8.0E1* EXV-10.0E1*
Dimensions (mm) & Weight (kg)
Height 431
Width 199
Depth 103
Weight 2.7 4.5
For full technical details, refer to Technical Manual
Outdoor UnitDX-Kit
Allowed Heat Exchanger Capacity (kW) Heat Exchanger Volume (dm3)
Utopia IVX Utopia ES Code Mode Nominal Min Max Min Max
- RAS 2HVRN2 EXV-2.0ECooling 5.0 4.0 5.6
0.57 1.16Heating 5.6 4.5 7.1
- RAS 2.5HVRN2 EXV-2.5ECooling 6.0 4.8 6.3
0.89 1.35Heating 7.0 5.6 7.1
RAS 3HVRNM2E RAS 3HVRNS2 EXV-3.0ECooling 7.1 5.7 8.0
1.03 1.57Heating 8.0 6.4 9.0
RAS 4H(V)RNM2E RAS 4H(V)RNS2E EXV-4.0ECooling 10.0 8.0 11.2
1.51 2.37Heating 11.2 9.0 12.5
RAS 5H(V)RNM2E RAS 5H(V)RNS2E EXV-5.0ECooling 12.5 10.0 14.0
1.92 2.37Heating 14.0 11.2 16.0
RAS 6H(V)RNM2E RAS 6H(V)RNS2E EXV-6.0ECooling 14.0 11.2 16.0
1.92 2.92Heating 16.0 12.8 18.0
RAS 8HRNM RAS 8HRNS EXV-8.0ECooling 20.0 16.0 22.4
2.92 3.89Heating 22.4 17.9 25.0
RAS 10HRNM RAS 10HRNS EXV-10.0ECooling 25.0 20.0 28.0
3.89 4.76Heating 28.0 22.4 31.5
Twin, Triple and Quad Splits
Features and Benefits
Set Free VRF Systems
Control SystemsMini
2-pipeFS(V)N(Y)(2)(E.)
Sideflow2-pipeFSNM
Modular2-pipeFSXN
Modular3-pipeFSXN
Nominal Cooling Capacity (kW) 8.0 ~ 16.0 22.4 ~ 33.5 22.4 ~ 150.0 22.4 ~ 150.0
Nominal Heating Capacity (kW) 9.0 ~ 18.0 25.0 ~ 37.5 25.0 ~ 165.0 25.0 ~ 165.0
Power Supply 1Ø / 3Ø 3Ø 3Ø 3Ø
Refrigerant R410A R410A R410A R410A
Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter
Operating Range (Cooling) (db) -5ºC / +43ºC -15ºC / +43ºC -5ºC / +43ºC -5ºC / +43ºC
Operating Range (Heating) (wb) -20ºC / +15ºC -20ºC / +15ºC -15ºC / +15ºC -20ºC / +15ºC
Connection Ratio 50 ~ 130% 50 ~ 130% 50 ~ 130% 50 ~ 130%
Indoor Unit Quantity 1 ~ 9 1 ~ 10 1 ~ 64 1 ~ 64
Indoor Unit Type All System Free Indoor Units
Control Systems Individual, groups, centralised and BMS
All Set Free VRF Systems
coil temperature setting on all indoor units
whole range
loads and energy savings
Individual control options are Infra red remote controller with 24hr timer, simplified hard wired controller or hard wired remote controller with built in 7-day timer.
FS(V)(Y)N2E Mini 2-pipe
COP of 4.14 and EER of 4.07.
Hitachi Product Catalogue | 59
FSNM 2-pipe
Any combination of 10 System Free indoor units with a total diversity of 50-130% can be individually controlled
The unit uses a horizontal discharge twin fan design allowing for more efficient use of floor space.
FSXN Modular 2 or 3-pipe
3-pipe heat recovery to suit customer requirements
Two highly-effective heat pump systems in one unit:A two-pipe system for open plan environments and a three-pipe system for individual spaces, allowing your customers to tailor their air conditioning needs to meet a diverse range of building requirements
Select from 3 settings with up to 8dB noise reduction.
Hitachi FSXN VRF
Offer 2-pipe and 3-pipe options from a single unit for air conditioning that can be tailored to meet changing building requirements
Visit hitachiaircon.com/tomorrowto find out more
RAS-FSVNE
Mini 2-pipe
Outdoor 1Ø RAS-3FSVNE RAS-4FSVN2E RAS-5FSVN2E RAS-6FSVN2EOutdoor 3Ø - RAS-4FSNY2E RAS-5FSNY2E RAS-6FSNY2E
Nominal Capacity (kW)Cooling 8.0 11.2 14.0 15.5Heating 9.0 12.5 16.0 18.0
UK Cooling Capacity (kW) Total 7.4 10.4 13.0 14.4
EER/COP Cooling 3.54 4.07 3.61 3.32Heating 3.59 4.14 3.81 3.67
Maximum number of Indoor Units No. 4 6 8 9Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 45 (41) 49 (45) 51 (47) 51 (48)Heating 47 51 53 53
Dimensions (mm) & Weight (kg)
Height 800 1380Width 850 950Depth 315 370Weight 66 97 97 97
Operating Range (ºC)Cooling -5ºC / +43ºC (db) -5ºC / +46ºC (db)Heating -20ºC / +15ºC (wb)
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Piping (m)Total Length 65 125 125 125
Lift 25 30 30 30Pre-charged Calculate Calculate Calculate Calculate
Power Supply1Ø 220-240V 50Hz
- 3Ph 380-415V 50HzStarting Current (1Ø/3Ø) (A) 7.0 / - 10.5 / 5.0 15.0 / 5.0 15.0 / 5.0
Running Current (1Ø/3Ø) (A)Cooling 9.6 / - 12.2 / 4.1 17.2 / 5.8 20.7 / 7.0Heating 10.7 / - 13.4 / 4.6 18.6 / 6.3 21.7 / 7.4
Recommended Fuse Size (1Ø/3Ø) (A) 25 / - 25 / 16 32 / 16 32 / 16
RAS 8FSNM RAS 10FSNM RAS 12FSNM
Nominal Capacity (kW)Cooling 22.4 28.0 33.5Heating 25.0 31.5 37.5
UK Cooling Capacity (kW) Total 20.8 26.0 31.2
EER/COP (Outdoor Only)Cooling 3.56 3.37 3.13Heating 4.24 4.04 3.79
Maximum number of Indoor Units No. 10 10 10Outdoor Sound Pressure Level (Set Back) dB(A)
Cooling 53 (50) 56 (53) 59 (55)Heating 55 58 55
Dimensions (mm) & Weight (kg)
Height 1650Width 1100Depth 390Weight 170 170 173
Operating Range (ºC)Cooling (-5 ~ 43)dbHeating (-20 ~ 15)wb
Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 12.7(1/2) 12.7(1/2)Gas 19.05 (3/4) 22.20 (7/8) 22.20 (7/8)
Piping (m)Total Length 250 250 250
Lift 40 40 40Pre-charged Calculate Calculate Calculate
Power Supply 3Ø 380-415V 50HzStarting Current (A) 8 8 8
Running Current (A)Cooling 9.4 12.4 15.8Heating 8.8 11.7 14.7
Recommended Fuse Size (A) 16 20 25
RAS FSNM
RAS-FS(V)(Y)N2E
Sideflow 2-pipe
Set Free VRF Systems
Hitachi Product Catalogue | 61
For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394
Modular
Set Free VRF Systems
RAS 8FSXN RAS 10FSXN RAS 12FSXN RAS 14FSXN RAS 16FSXN RAS 18FSXN
Nominal Capacity (kW)Cooling 22.4 28.0 33.5 40.0 45.0 50.0Heating 25.0 31.5 37.5 45.0 50.0 56.0
UK Cooling Capacity (kW) Total 19.3 24.1 28.8 34.4 38.7 43.0
EER/COP (Outdoor)Cooling 3.85 3.79 3.41 3.25 3.23 3.37Heating 4.17 4.11 3.60 3.89 3.90 3.81
Maximum number of Indoor Units No. 13 16 19 23 26 26
Outdoor Sound Pressure Level (Set Back) dB(A) Cooling 58 (53) 58 (53) 60 (55) 62 (57) 62 (57) 63 (58)
Dimensions (mm) & Weight (kg)
Height 1720 1720 1720 1720 1720 1720Width 950 950 950 1210 1210 1210Depth 765 765 765 765 765 765Weight 225 225 225 315 315 335
Operating Range (ºC)Cooling -5ºC / +43ºCHeating -20ºC / +15ºC
Refrigerant Piping (mm) (in) Liquid 9.53 (3/8) 9.53 (3/8) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 15.88 (5/8)
Gas 19.05 (3/4) 22.22 (7/8) 28.57 (1 1/8) 28.57 (1 1/8) 28.57 (1 1/8) 28.57 (1 1/8)
Piping (m)Max. Length 1000 1000 1000 1000 1000 1000
Lift 50 50 50 50 50 50Pre-charged Calculate Calculate Calculate Calculate Calculate Calculate
Power Supply 3Ø 380-415V 50HzStarting Current (A) 8 8 8 95 95 113
Running Current (A)Cooling 9.3 11.9 15.7 20.2 22.6 24.1Heating 9.6 12.3 16.7 18.8 20.8 23.8
Recommended Fuse Size (A) 16 20 25 32 32 32
Model RAS 20FSXN RAS 22FSXN RAS 24FSXN RAS 26FSXN RAS 28FSXN RAS 30FSXN
CombinationsRAS 8FSXN RAS 8FSXN RAS 10FSXN RAS 12FSXN RAS 14FSXN RAS 14FSXN
RAS 12FSXN RAS 14FSXN RAS 14FSXN RAS 14FSXN RAS 14FSXN RAS 16FSXN
Model RAS 32FSXN RAS 34FSXN RAS 36FSXN RAS 38FSXN RAS 40FSXN RAS 42FSXN
CombinationsRAS 16FSXN RAS 16FSXN RAS 18FSXN RAS 12FSXN RAS 12FSXN RAS 12FSXNRAS 16FSXN RAS 18FSXN RAS 18FSXN RAS 12FSXN RAS 12FSXN RAS 12FSXN
- - - RAS 14FSXN RAS 16FSXN RAS 18FSXN
Model RAS 44FSXN RAS 46FSXN RAS 48FSXN RAS 50FSXN RAS 52FSXN RAS 54FSXN
CombinationsRAS 12FSXN RAS 12FSXN RAS 12FSXN RAS 14FSXN RAS 16FSXN RAS 18FSXNRAS 14FSXN RAS 16FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXNRAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN
Combinations
For full technical details, refer to Technical Manual
RAS FSXN
Hitachi Product Catalogue | 63
System free Indoor Units
Set Free VRF Systems
RCD-FSN2
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0
Size 20 25 32 40 - 50 - 63 71 100 125
2-Way Cassette RCD-FSN2
(including grille) Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1 8.0 11.2 14.0
Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5 9.0 12.5 16.0
UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4 7.5 10.5 12.7
UK Sensible Cooling (kW) 1.7 2.1 2.5 2.8 3.2 3.9 4.4 4.7 5.6 7.7 8.8
RCI-FSN3E
HP 0.8 1.0 1.3 1.5 1.8 2.0
Size 20 25 32 40 - 50
Mini 4-Way Cassette RCIM-FSN2
(including grille) Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6
Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3
UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2
UK Sensible Cooling (kW) 1.6 1.9 2.5 2.9 3.1 3.7
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0
Size 20 25 32 40 - 50 - 63 71 100 125 140
4-Way Cassette RCI-FSN3E
(including grille) Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1 8.0 11.2 14.0 16.0
Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5 9.0 12.5 16.0 18.0
UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4 7.5 10.5 12.7 14.8
UK Sensible Cooling (kW) 1.7 2.1 2.6 3.0 3.4 4.1 4.4 4.7 5.9 8.2 9.4 10.8
CH-6.0N1 CH-10.0N1
Nominal Capacity HP HP 6 6 < HP 10Maximum number of Indoor Units - 7 8Input power Watts 20 20
Dimensions (mm) & Weight (kg)
Height 191 191Width 301 301Depth 214 214Weight 7 7
Refrigerant - R410A (charged with nitrogen to avoid corrosion)Refrigerant pipe connections Flared connections with nuts and/or flange (factory-supplied)
Refrigerant lines from the outdoor unit(1)
Low pressure ø15.88mm (5/8") ~ ø19.05mm (3/4") ø19.05mm (3/4") ~ ø22.2mm (7/8")High pressure ø12.7mm (1/2") ~ ø15.88mm (5/8") ø15.88mm (5/8") ~ ø19.05mm (3/4")
Refrigerant lines from the indoor unit(1)
Liquid line As appropriate for indoor unit capacity (bypasses CH Box)Gas line ø12.7mm (1/2") ~ ø15.88mm (5/8") ø19.05mm (3/4") ~ ø22.2mm (7/8")
CH Boxes
For full technical details, refer to Technical Manual
RCIM-FSN2
S Y S T E MFREE
Capacity available with dip switch setting capacity range (HP) Adjustable by dipswitch setting+
hitachiaircon.com Email: [email protected]: 01628 585 394
For full technical details, refer to Technical ManualFor our full range of controls and accessories see pages 88 and 89.
System free Indoor Units
Set Free VRF Systems
RPI-FSN2E
HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0 8.0 10.0Size - 50 - 63 71 100 125 140 200 250
In the Ceiling RPI-FSN3E(Standard) Nominal Cooling (kW) 5.0 5.6 6.5 7.1 8.0 11.2 14.0 16.0 22.4 28.0
Nominal Heating (kW) 5.7 6.3 7.8 8.5 9.0 12.5 16.0 18.0 25.0 31.0
UK Total Cooling (kW) 4.3 5.2 6.0 6.4 7.5 10.5 12.7 14.8 18.4 22.9
UK Sensible Cooling (kW) 3.3 4.0 4.6 4.9 5.6 7.7 9.1 10.7 14.2 18.1
RPI-FSN3E
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0Size 20 25 32 40 - 50 - 63 71 100
Wall Mounted RPK-FSN2MNominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1 8.0 11.2
Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5 9.0 12.5
UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4 7.5 10.5
UK Sensible Cooling (kW) 1.5 1.9 2.5 2.8 3.1 3.7 4.5 4.8 5.6 7.5
RPK-FSN2M
HP 0.8 1.0 1.3 1.5Size 20 25 32 40
Mini In The Ceiling RPIM-FSN2E(Slim Width) Nominal Cooling (kW) 2.2 2.8 3.8 4.0
Nominal Heating (kW) 2.5 3.2 4.3 4.8
UK Total Cooling (kW) 2.1 2.6 3.4 3.9
UK Sensible Cooling (kW) 1.7 2.1 2.4 2.8
RPIM-FSN2ERPIM FSN E
HP 0.8 1.0 1.3 1.5Size 20 25 32 40
In the Ceiling RPI-FSN2E(Low Height) Nominal Cooling (kW) 2.2 2.8 3.8 4.0
Nominal Heating (kW) 2.5 3.2 4.3 4.8
UK Total Cooling (kW) 2.1 2.6 3.4 3.9
UK Sensible Cooling (kW) 1.7 2.1 2.4 2.8
HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0Size - 50 - 63 71 100 125 140
Ceiling Suspended RPC-FSN2ENominal Cooling (kW) 5.0 5.6 6.5 7.1 8.0 11.2 14.0 16.0
Nominal Heating (kW) 5.7 6.3 7.8 8.5 9.0 12.5 16.0 18.0
UK Total Cooling (kW) 4.3 5.2 6.0 6.4 7.5 10.5 12.7 14.8
UK Sensible Cooling (kW) 3.1 3.7 4.3 4.6 5.4 7.6 9.1 10.7
RPC-FSN2E
S Y S T E MFREE
Capacity available with dip switch setting capacity range (HP) Adjustable by dipswitch setting+
Hitachi Product Catalogue | 65
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 32 40 - 50 - 63
Floor Mounted RPFI-FSN2EUncased Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1
Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4UK Sensible Cooling (kW) 1.5 1.9 2.5 2.8 3.1 3.8 4.4 4.7
RPFI-FSN2E
RPF-FSN2E
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 32 40 - 50 - 63
Floor Mounted RPF-FSN2ECased Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1
Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4UK Sensible Cooling (kW) 1.5 1.9 2.5 2.8 3.1 3.8 4.4 4.7
System free Indoor Units
Set Free VRF Systems
For full technical details, refer to Technical Manual
Model
PC-ARTStandard Wired Remote Controller (inc. 7 Day Time Clock)
PC-ARFWired LED Controller with advanced graphical interface (inc 7 Day Time Clock)
PC-ARH Simple Wired Remote Controller
PC-LH3AWireless Remote Controller (Receiver kit required inc. with RPK-FSN2M)
PC-ALHN Receiver Kit panel mounted (RCI-FSN3E)
PC-ALHD Receiver Kit panel mounted (RCD-FSN3E)
PC-ALHC Receiver Kit panel mounted (RCIM-FSN3E)
PC-ALHZ Receiver Kit wall mounted (All System Free Indoor Units)
System Free Accessories / Pipe Kits
Pipe Kits (Set Free - Mini, Side Flow, Modular)
E-102SN2 Pipe Kit (2-pipe)
E-162SN2 Pipe Kit (2-pipe)
E 242SN2 Pipe Kit (2-pipe)
E 302SN2 Pipe Kit (2-pipe)
E 52XN2 Pipe Kit (3-pipe)
E 102XN2 Pipe Kit (3-pipe)
E 162XN2 Pipe Kit (3-pipe)
E 202XN2 Pipe Kit (3-pipe)
E 242XN2 Pipe Kit (3-pipe)
E 322XN2 Pipe Kit (3-pipe)
MH 84AN Pipe Kit (2-pipe header)
MH 108AN Pipe Kit (2-pipe header)
MH 108XN Pipe Kit (3-pipe header)
S Y S T E MFREE
Capacity available with dip switch setting capacity range (HP) Adjustable by dipswitch setting+
HP 1.5 2.0 2.5Size 40 50 63m³/hr 500 800 1000
Active KPI KPI-X3ENominal Cooling (kW) 5.3 8.0 10.8Nominal Heating (kW) 6.9 9.8 12.9Coil Cooling Cap. (kW) 1.8 2.9 3.7Coil Heating Cap. (kW) 2.1 3.5 4.4
Pipe Kits (Set Free - Mini, Side Flow, Modular)
MC 20ANModular Set Free 2-pipe Branch Kit (RAS 20~24FSXN)
MC 21ANModular Set Free 2-pipe Branch Kit (RAS 26~36FSXN)
MC 30ANModular Set Free 2-pipe Branch Kit (RAS 28~54FSXN)
MC 20XNModular Set Free 3-pipe Branch Kit (RAS 20~24FSXN)
MC 21XNModular Set Free 3-pipe Branch Kit (RAS 26~36FSXN)
MC 30XNModular Set Free 3-pipe Branch Kit (RAS 28~54FSXN)
NEW
Available from June 2012Provisional Data
hitachiaircon.com Email: [email protected]: 01628 585 394
Close Control
Features and Benefits
Twin DC Inverter
Specifically designed and developed to provide
a suitable environment for server and computer
rooms, telecommunications facilities and data
centres, where a need for high sensible cooling
and close control of temperature is required.
saving energy by reducing humidification
up to 160m with 70m* height difference
* special order
Hitachi Product Catalogue | 67
Indoor Unit Outdoor Unit
RP 20ACRN RCR 20ACN
Nominal Capacity (kW) 56.6
Sensible Cooling Capacity (kW) 56
Sound Pressure Level (Set Back) dB(A) 60 57 (54)
Dimensions (mm) & Weight (kg)
Height 1900 1980
Width 2145 1800
Depth 900 900
Weight 925 410
Fan
Model & Quantity Multi Blade Centrifugal x 2 Propeller x 2
Nominal Air Flow Rate (m³/min) 350 300
Static Pressure (Pa) 120 (Max. 300) 0 (60)(*1)
Air Inlet Upper Side Lower Side (Front Side: Optional(*2))
Air Outlet Lower Side Upper Side
Operating Range (ºC) -15ºC ~ +43ºC
Refrigerant Piping (mm) (in)
Liquid 12.7 (1/2) x 2 (Equivalent piping > than 120m: 15.88 (5/8) x 2)
Gas 19.05 (3/4) x 2 (Equivalent piping > than 120m: 22.22 (7/8) x 2)
Direction Bottom (Top - Optional)(*3) Bottom or Front or Rear
Piping (m)
Max. Equivalent 185
Max. Length 160
Lift 40 (70 special order)(*4)
Pre-charged 50
Power Supply 3Ø 380~415V 50Hz
Starting Current (A) Less than Running Current (Maximum Running Current: 49.5A)
Running Current (A) 31.7
Recommended Fuse Size (A) TBC TBC
NOTES:
1. The performance is indicated when the unit is operated under the following conditions:
Indoor Inlet Air Temperature: 27°C DB, 19°C WB Outdoor Inlet Air Temperature: 35°C DB; Refrigerant Piping Length: 5m (one-way, installed horizontally) at rated compressor frequency
2. The sound pressure level is indicated the value (A scale) measured under the following conditions:
Measurement Points Indoor Unit: 1m from unit front surface, 1m from floor level Measurement Points Outdoor Unit: 1m from unit front surface, 1.5m from floor level The above data was measured in an anechoic room, so that reflected sound should be taken into consideration in the field. In the case that air inlet port is provided at front surface (*2), more affected by reflected sound.
3. The external static pressure and airflow rate of the fan may not reach the standard value due to air outlet dimension and shape, or obstacles.
4. (*1): Required custom-ordered modification at factory. (*2): Required air inlet grille (optional) mounting. (*3) (*4): Required indoor unit custom-ordered modification at factory.
Indoor Unit ACRN
Close Controller HD2 PCP
Outdoor Unit ACN
Close Control
Twin DC Inverter
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 69
Close Control
Optional Accessories
Model
Condition
ApplicationsOptional Accessories
Modified at Factory
Indoor Unit
Modification for piping/wiring through top of unit - - Applicable Refrigerant piping and wiring is modified to connect
through the top of the unit
Modification for height difference up to 70m - - Applicable Applicable when the outdoor unit is installed higher
than the indoor unit
Connection piping set CPS-NP560L Applicable - When piping length is over 120m, piping diameter shall be sized up
Air inlet chamber BS-NP560D Applicable - When the duct is connected at air inlet side (upper part of the unit)
Temperature sensor THM-R2DM Applicable - When the multipoint temperature control is applied
Temperature-humidity sensor THU-R1D Applicable - When no-dehumidifying control or dehumidifying control by humidity sensor is applied
Outdoor Unit
Modification for high external static pressure switchover - - Applicable Modification for high external static pressure to be
switched over at control panel
Front side air inlet grille PN-NP560D Applicable - Modification to change air inlet from unit bottom side into unit front side
Bottom side protective grille PN-NP560SD Applicable - To prevent object from entering into unit
For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394
Features and Benefits
Ventilation
KPI-Energy, Heat Recovery and Active models
3/h
The Hitachi heat recovery ventilation system (KPI) adjusts the temperature and humidity of incoming fresh air to match the indoor environment
The fan motor is the only moving part resulting in low noise levels of 26dB(A) (NR28)
Fresh air supply for indoor environments
Energy recovery ventilation between supply and extract air supplies (forced energy exchange mode) efficiencies up to 78%
Automatic ventilation (KPI controls which mode to operate within to achieve maximum energy efficiency)
Ventilation mode (forced bypass mode)
As a consequence of the energy exchange during the summer period, the cooling load can be reduced by up to 20%, minimising both capital and running costs
Easy access hatches for the heat exchanger, motor, fans and electrical box allow in situ maintenance
as standard control option
Individual control or interfaced with Hitachi System Free fan coil
Compatible with H-LINK II Control and CS Net Web.
Econofresh
The Econofresh kit is an intelligent accessory device that is easy to install. The Econofresh kit can provide up to 100% fresh air and has the ability to provide “free cooling” when the outdoor temperature is below the indoor setting temperature. This kit in conjunction with the RPI In the Ceiling system will not only maintain the correct room temperature and provide fresh air, but also natural cooling therefore increasing energy savings.
Fresh air cooling during intermediate seasons saves energy. This unit uses an economiser for cooling, which takes in fresh air if the outdoor temperature is cooler than the indoor air. No compressor is used and thus a remarkable amount of energy is saved
A fresh air intake system keeps the air in a room clean at all times. The optional CO2 sensor can sense the degree of pollution of the air in the room and automatically control the fresh air flow
Utilising the free cooling potential of the UK climate, the combination of the Econofresh and the RPI 5.0FSN3E can reduce the power input required by more than 20% when compared to a standard RPI 5.0FSN3E system
Hard wired remote controller with built in 7 day timer (as per RPI-FSN3E In the Ceiling unit)
Optional simplified hard wired or infra red remote controller with 24hr timer
Compatible with H-LINK II Control and CS Net Web controls that integrate with all leading BMS protocols.
Hitachi Product Catalogue | 71
Product Summary KPI Energy Recovery KPI Heat Recovery Active KPI Econofresh
Model KPI-E3E (1) KPI-H3E (1) KPI-X3E (2) EF
Air Volume (m3/min) 250 ~ 2,000 500 ~ 2,000 500 ~ 1,000 21 ~ 210
Total Enthalpy Heat Exchange - -
Sensible Heat Exchange -
Bypass Ventilation -
Free Cooling 10 ~ 100%
DX Coil - - -
EC Fans - EuP Lot 11 2nd Tier Compliant -
Automatic Ventilation via CO2 Sensor input
High Efficiency Filter (F7 based on EN779) Option Option Option -
Power Supply 1Ø 220-240V 50Hz Power supplied from RPI 5.0FSN3E
Fan Coil Type Individual Requires RPI 5.0FSN3E
Remote Controller Type Wired or Infra Red
Remote Control Timer 24hr or 7 Day Option
(1) KPI-E3E and KPI-H3E Series models available from June 2012 (check with Hitachi Sales Office)
Series 2 KPI-E2E and KPI-H2E models will remain available until June 2012
(2) KPI-X3E models will be available from June 2012 (check with Hitachi Sales Office)
KPI Energy Recovery
Ventilation
Total Energy Recovery KPI 252E3E KPI 502E3E KPI 802E3E KPI 1002E3E KPI 1502E3E KPI 2002E3E
Air Flow Rate (m3/h) H/M/L 250-208-180 500-420-360 800-700-597 1000-800-620 1500-1250-970 2000-1560-1240
External Static Pressure (1) (Pa) H/M/L 60-40-30 77-50-47 100-75-55 120-80-50 132-90-60 135-84-60
Boost External Static Pressure (Pa) 200 (250m³/h) 227 (500m³/h) 200 (800m³/h) 195 (1000m³/h) 246 (1500m³/h) 180 (2000m³/h)
Sound Pressure Level (2) (dB(A) H/M/L 27-26-24 30-28-27 32-31-30 35-32-30 37-35-33 39-38-35
Heat Exchanger Element Air to Air cross flow Celluloid material (Total Energy Exchange)
Temp Exchange Efficiency (%) 75 75 75 78 78 78
Enthalpy Exchange Efficiency (Heat) 66 65 65 68 68 66.5
Enthalpy Exchange Efficiency (Cool) 60 61 62 62 62.5 61.5
Dimensions (mm) & Weight (kg)
Height 270 330 385 385 525 525
Width 900 1130 1210 1600 1800 1800
Depth 750 920 1015 1295 1130 1430
Weight TBC TBC TBC TBC TBC TBC
Duct Sizes (dia) (mm) 150 200 250 300 355 355
Supplied Air Filter Class (EN779) (4) G3 G3 G3 G3 G3 G3
Operation Range (3) -20 ~ 46°C
Power Supply 1 ~ 230V 50Hz
Running Current (230V) (A) 0.2 0.4 1.0 1.2 1.9 2.7
Recommended Fuse Size (A) 5 5 5 5 5 5
Series 3 KPI-E3E data is provisional (check with Hitachi Sales Office)
KPI-E3E and KPI-H3E Series models available from June 2012 (check with Hitachi Sales Office)
Series 2 KPI-E2E and KPI-H2E models will remain available until June 2012
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 73
PC-ARTKPI-E(H)(2)E
KPI Heat Recovery
Ventilation
Heat Recovery KPI 502H3E KPI 802H3E KPI 1002H3E KPI 1502H3E KPI 2002H3E
Air Flow Rate (m3/h) H/M/L 500-420-360 800-700-597 1000-800-620 1500-1250-970 2000-1560-1240
External Static Pressure (1) (Pa) H/M/L 77-50-47 100-75-55 120-80-50 132-90-60 135-84-60
Boost External Static Pressure (Pa) 227 (500m³/h) 200 (800m³/h) 195 (1000m³/h) 246 (1500m³/h) 180 (2000m³/h)
Sound Pressure Level (2) (dB(A) H/M/L 30-28-27 32-31-30 35-32-30 37-35-33 39-38-35
Heat Exchanger Element Air to Air cross flow Aluminium material (Heat Exchange)
Temp Exchange Efficiency (%) 53 50 50 49 48
Enthalpy Exchange Efficiency (Heat) 35 34 33 31 31
Enthalpy Exchange Efficiency (Cool) 30 28 28 27 28
Dimensions (mm) & Weight (kg)
Height 330 385 385 525 525
Width 1130 1210 1600 1800 1800
Depth 920 1015 1295 1130 1430
Weight TBC TBC TBC TBC TBC
Duct Sizes (dia) (mm) 200 250 300 355 355
Supplied Air Filter Class (EN779) (4) G3 G3 G3 G3 G3
Operation Range (3) -20 ~ 46°C
Power Supply 1 ~ 230V 50Hz
Running Current (230V) (A) 0.4 1.0 1.2 1.9 2.7
Recommended Fuse Size (A) 5 5 5 5 5
Series 3 KPI-H3E data is provisional, (check with Hitachi Sales Office) KPI-E3E and KPI-H3E
Series models available from June 2012 (check with Hitachi Sales Office)
Series 2 KPI-E2E and KPI-H2E models will remain available until June 2012
If a KPI is operated individually add the PC-ART / PC-ARF remote controller to the price. For details of interlocks with Utopia & Set Free systems contact your local sales office. (1) Default fan pressure setting(2) Sound pressure level has been measured in an anechoic chamber, with the measuring point 1.5m below the centre of the unit,
with no ceiling under the unit and using a sound insulated duct. Reflected sound must be considered when installing the unit in the field.(3) The installation of an electric heater is necessary when temperature becomes lower than -5ºC(DB).(4) High efficiency filter class F7 (EN779) is available as accessory.
For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394
Active KPI
Ventilation
Active - Total Energy Recovery
KPI 502X3E KPI 802X3E KPI 1002X3E
Hp 1.5 2.0 2.5
Size 40 50 63
Nominal Set Free Capacity (1) Brackets = Coil Cap. (kW)
Cooling 5.3 (1.8) 8.0 (2.9) 10.8 (3.7)
Heating 6.9 (2.1) 9.8 (3.5) 12.9 (4.4)
Nominal Utopia Capacity (1) Brackets = Coil Cap. (kW)
Cooling - 7.4 (2.9) 9.7 (3.7)
Heating - 9.1 (3.5) 11.4 (4.4)
Air Flow Rate (m³/h) H/M/L 500-430-380 800-700-590 1000-820-740
External Static Pressure (2) (Pa) H/M/L 150-120-100 125-95-70 120-85-70
Boost External Static Pressure (Pa) 235 (500m³/h) 125 (800m³/h) 125 (1000m³/h)
Sound Pressure Level (3) (dB(A) H/M/L 29-27-26 31-30-29 35-32-30
Heat Exchanger Element Air to Air cross flow Celluloid material (Total Energy Exchange)
Temp Exchange Efficiency (%) 75 75 78
Enthalpy Exchange Efficiency (Heat) 65 65 68
Enthalpy Exchange Efficiency (Cool) 61 62 62
Dimensions (mm) & Weight (kg)
Height 330 385 385
Width 1630 1710 2100
Depth 920 1015 1295
Weight TBC TBC TBC
Refrigerant Piping (mm (in))Liquid 6.35 (1/4) 6.35 (1/4) 9.53 (3/8)
Gas 12.7 (1/2) 15.88 (5/8) 15.88 (5/8)
Duct Sizes (dia) (mm) 200 250 300
Supplied Air Filter Class (EN779) (5) G3 G3 G3
Operation Range (4) -20 ~ 46°C
Power Supply 1 ~ 230V 50Hz
Running Current (230V) (A) 0.7 1.2 1.5
Recommended Fuse Size (A) 5 5 5
Series 3 KPI-X3E data is provisional, (check with Hitachi Sales Office)
KPI-X3E models will be available from June 2012 (check with Hitachi Sales Office)
If a KPI is operated individually add the PC-ART / PC-ARF remote controller to the price. For details of interlocks with Utopia & Set Free systems contact your local sales office. (1) The nominal cooling and heating capacity is the combined capacity of the outdoor and indoor units of the system and is based on Standard EN14511.(2) Default fan pressure setting.(3) Sound pressure level has been measured in an anechoic chamber, with the measuring point 1.5m below the centre of the unit, with no ceiling under the unit and
using a sound insulated duct. Reflected sound must be considered when installing the unit in the field.(4) The installation of an electric heater is necessary when temperature becomes lower than -5ºC(DB).(5) High efficiency filter class F7 (EN779) is available as accessory.
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 75
EF-NE
New ModelModel descriptionEF 5NE
Econofresh KitRPI-5HP
Econofresh Kit EF 5NE
Dimensions (mm) & Weight (kg)
Height 254
Width 1350+59
Length 270
Weight 12.5
Typical Free Cooling Range (ºC) 3ºC ~ 19ºC
Power Supply Supplied from RPI 5FSN3E
Interconnecting Cables Supplied
Remote Controller Type via Indoor Unit Controller
Econofresh Kit
Ventilation
Econofresh Indoor Unit System
EF 5NE RPI 5FSN3E Utopia ES (5, 10HP)
EF 5NE RPI 5FSN3E Utopia IVX (5 ~ 12HP)
EF 5NE RPI 5FSN3E Utopia Centrifugal (5, 10HP)
EF 5NE RPI 5FSN3E Set Free - Mini, Side Flow, Modular
System Possibilities
For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394
Features and Benefits
Domestic Heating
Yutaki-M – Monobloc air to water heat pump
A compact solution where a single unit is
installed on the outside of the property, taking up
no space inside and can be used alongside an
existing heating solution.
(55ºC for 4~6HP)
ideal boiler replacement technology
handling required
renewable heat incentive
holiday button and frost protection as standard
Yutaki-S – Split type air to water heat pump
A split system with auxiliary heating as standard.
separate outdoor unit
settings – ideal boiler replacement technology
(2HP model)
holiday button and frost protection as standard
Heating Manufacturer of the Year “ The judges felt Hitachi provided an excellent
submission, a great product and the way forward.”Hitachi’s Yutaki M Heat Pump
Hitachi Product Catalogue | 77
Product Summaryyy YutYutYuY akikiaki M-M-M-M YutYYutYutakiakiak -S-SS
Model RHURHURH E-AE-AE-A(V)(V)(V HN(HN(HN(1)-1)-1 (HM(HM(HMHM)) RWMRWMRW -FS-FS-FSN3EN3EE RWMRWMWM-HF-HFSN3SN3EE
Nominal Heatttatiingingi Ca Capacity (kW) 7.17.17 1 ~ ~ 17.1717.55 2.32.33 ~ ~ 32.3232.2222 2.32.3 ~ ~ 32.332.2 22
Nominal CCCCooloo ingng Capacity (kW) - 1.81.88 ~ ~ ~ 20.20.0 888 -
Refrigggeeraeraerantntnt R4R41R44 0A0A0A R41R41R 0A0A0A R41R41R4110A0A00A0A
Capapapapacicityty Control DC-InInverterte erer DC-DC-DCDC InvIInvInvertertererer DCCCDC-Invnverterterer
Operating Range (Heating) (wb) -20ºC / ++37.5ºC5ºC -2 -220ºC0º0ºC / / +35+35+353 ºCºCºCC -2 -20ºC0ºC / / +35+ ºC
Operatinng Range (Cooling) (db) - -10-10ºC ºC C / +/ +/ +/ ++46º46º46º46º6 CCCC -
Energy RRating A AAA A
Remote Controller Type Wireless Wireless
Remote CCoC ntrol Timer 24hr or 7 Day option 24hr or 7 Day option
Domestic Heating
Yutaki-M
Outdoor 1Ø RHUE 3.0AVHN1 RHUE 4.0AVHN-HM RHUE 5.0AVHN-HM RHUE 6.0AVHN-HM
Outdoor 3Ø - - RHUE 5.0AHN-HM RHUE 6.0AHN-HM
Capacity1 Nominal (min~max) (kW) Water (in/out) 30/35ºC 7.5 (6.2 ~ 11.0) 9.5 (5.0 ~ 10.9) 12.0 (6.9 ~ 15.0) 14.0 (7.8 ~ 17.5)
COP Ambient (db/wb) 7/6ºC 4.43 4.06 4.01 4.31
Capacity2 Nominal (min~max) (kW) Water (in/out) 40/45ºC 7.1 (5.9 ~ 10.2) 9.2 (5.0 ~ 10.2) 11.3 (6.8 ~ 14.0) 13.3 (7.6 ~ 16.5)
COP Ambient (db/wb) 7/6ºC 3.34 3.05 3.01 3.35
Capacity3 Nominal (min~max) (kW) Water (in/out) 47/55ºC 6.4 (5.3 ~ 9.3) - - -
COP Ambient (db/wb) 7/6ºC 2.71 - - -
Capacity4 Nominal (min~max) (kW) Water (in/out) 30/35ºC 6.5 (3.5 ~ 7.1) 6.9 (3.8 ~ 7.9) 8.4 (5.2 ~ 10.9) 9.3 (6.1 ~ 12.3)
COP Ambient (db/wb) -7/-8ºC 2.4 2.55 2.61 2.6
Capacity5 Nominal (min~max) (kW) Water (in/out) 40/45ºC 6.4 (3.4 ~ 6.9) 6.5 (3.7 ~ 7.7) 8.1 (5.0 ~ 10.5) 9.0 (5.8 ~ 12.0)
COP Ambient (db/wb) -7/-8ºC 2.01 2.22 2.28 2.21
Capacity6 Nominal (min~max) (kW) Water (in/out) 47/55ºC 6.2 (3.3 ~ 6.6) - - -
COP Ambient (db/wb) -7/-8ºC 1.82 - - -
Water Flow Nominal (min~max) (m³/hr) 1.29 (0.9 ~ 2.6) 1.92 (0.6 ~ 3.3) 2.4 (0.8 ~ 4.0) 2.4 (0.8 ~ 4.7)
Water Volume (minimum installation) (l) 28 38 46 56
Sound Pressure level dB(A) 49 49 51 52
Dimensions (mm)& Weight (kg)
Height 800 1480
Width 1250 1250
Depth 440 444
(1Ø/3Ø) Weight 110 / - 150 / - 155 / 160 159 / 164
Operating Range (ºC) Heating (-20 ~ +40)db
Power Supply1 Phase 1Ph 220-240V 50Hz
3 Phase - - 3Ph 380-415V 50Hz
Running Current (1Ø/3Ø) (A) (excludes pump) 7.5 / - 13.4 / - 16.6 / 7.7 17.6 / 8.2
Starting Current (A) < 10 < 10 < 10 < 10
Recommended Fuse Size (A) (1Ø/3Ø) 25 / - 25 / - 32 / 16 40 / 20
Heat
ing
Capa
city
For full technical details, refer to Technical Manual
Heating Manufacturer of the Year “ The judges felt Hitachi provided an excellent
submission, a great product and the way forward.”Hitachi’s Yutaki M Heat Pump
RHUE-A(V)HN(1) AF-RTU-01
Hitachi Yutaki heat pumps
The perfect heating and cooling solution for modern homes
Visit hitachiheating.comto find out more about our range of air source heat pumps
Hitachi Product Catalogue | 79
* Performed at the flow rate obtained during testing of the Yutaki-S at standard ambient rating conditions 7°C/6°C dB/wBPrice does not include room thermostat (see page 82)
For full technical details, refer to Technical Manual
Outdoor 1Ø RAS 2HVRN2 RAS 3HVRNME-AFOutdoor 3Ø - -
Outdoor Sound Pressure Level(Set Back) d(B)A
Cooling 45 (43) 42 ( 38)
Heating 47 50
Dimensions (mm)& Weight (kg)
Height 600 800Width 792 950Depth 300 370Weight 42 67
Operating Range (ºC)Cooling (10 ~ 46)ºC dbHeating (-20 ~ 35)ºC wb
Refrigerant Piping (mm) (in)Liquid 6.35(1/4) 9.52(3/8)Gas 12.7(1/2) 15.88(5/8)
Piping (m)Length 30 30
Lift (OU lower than IU) 30 / (20) 30 / (20)Pre-charged 30 30
Power Supply1 Phase 1Ph 220-240V 50Hz3 Phase - -
Starting Current (A) < 10 < 10
Running Current (1Ø/3Ø) (A)Cooling 5.2 8.2Heating 4.1 6.8
Recommended Fuse Size (A) 16 / - 25 / -
RAS-H(V)RNM(E)
AF-RTU-02
Yutaki-S
Outdoor Units
RAS-4/5H(V)RNME
RWM-FSN3E
Heating & Cooling RWM 2.0FSN3E RWM 3.0FSN3E
Heating only RWM 2.0HFSN3E RWM 3.0HFSN3E
Capacity Nominal (min~max) (kW) Water (in/out) 30/35ºC 5.1 (2.3 ~ 8.0) 7.5 (3.1 ~ 11.0)
COP Ambient (db/wb) 7/6ºC 5.02 4.55
Capacity Nominal (min~max) (kW) Water (in/out) 40/45ºC 4.7 (2.2 ~ 7.5) 7.1 (2.8 ~ 9.7)
COP Ambient (db/wb) 7/6ºC 3.51 3.47
Capacity Nominal (min~max) (kW) Water (in/out) 47/55ºC 4.2 (2.0 ~ 5.5) 6.2 (2.4 ~ 7.6)
COP Ambient (db/wb) 7/6ºC 2.63 2.65
Capacity Nominal (min~max) (kW) Water (in/out) */35ºC 4.0 (1.9 ~ 4.7) 6.4 (3.5 ~ 7.5)
COP Ambient (db/wb) -7/-8ºC 2.65 2.51
Capacity Nominal (min~max) (kW) Water (in/out) */45ºC 3.8 (1.8 ~ 4.4) 6.0 (3.3 ~ 6.9)
COP Ambient (db/wb) -7/-8ºC 2.10 2.33
Capacity Nominal (min~max) (kW) Water (in/out) */55ºC 3.0 (1.6 ~ 3.9) 5.3 (2.9 ~ 5.5)
COP Ambient (db/wb) -7/-8ºC 1.62 1.80
Capacity Nominal (min~max) (kW) Water (in/out) 12/7ºC 3.8 (1.8 ~ 5.4) 6.0 (2.5 ~ 6.9)
COP Ambient (db/wb) 35/-ºC 3.05 3.07
Capacity Nominal (min~max) (kW) Water (in/out) 23/18ºC 5.4 (2.6 ~ 7.5) 7.1 (3.0 ~ 8.0)
COP Ambient (db/wb) 35/-ºC 3.83 4.03
Water Flow Nominal (min~max) (m³/hr) 0.9 (0.5 ~ 2.2) 1.3 (0.9 ~ 2.6)Water Volume (minimum installation) (l) 28 28Sound Pressure level dB(A) 26 27
Dimensions (mm)& Weight (kg)
Height 890Width 520Depth 360Weight 55 56
Water Pipe Connection Inlet & Outlet G 1-1/4" (male) G 1-1/4" (male)Pump Input Power (watts) 75 100Electric Heater Power (kW) Steps 1.0/2.0/3.0 1.0/2.0/3.0Colour White (RAL 9016)
Power Supply1 Phase 1Ph 220-240V 50Hz3 Phase - -
Running Current (1Ø/3Ø) (A) Elec. Heater + Pump 13.3 13.5Recommended Fuse Size (1Ø/3Ø) (A) 20 20
Heat
ing
Capa
city
Cool
ing
Capa
city
Domestic Heating
Domestic Heating
Hitachi Product Catalogue | 81
RAS 4HVRNME-AF RAS 5HVRNME-AF RAS 6HVRNME-AF - -RAS 4HRNME-AF RAS 5HRNME-AF RAS 6HRNME-AF RAS 8HRNME-AF RAS 10HRNME-AF
44 (40) 46 (42) 48 (45) 52 (50) 55 (53)
52 55 55 54 561380 1650950 1100370 390
107 108 108 170 170(10 ~ 46)ºC db
(-20 ~ 35)ºC wb9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)* 12.70(1/2)*
15.88(5/8) 15.88(5/8) 15.88(5/8) 28.6(1/8)* 28.6(1/8)*30 30 30
30 / (20) 30 / (20) 30 / (20) 30 / (20) 30 / (20)30 30 30 30 30
1Ph 220-240V 50Hz - -3Ph 380-415V 50Hz
< 10 < 10 < 10 < 10 < 109.8 / 3.3 12.8 / 4.3 17.2 / 5.7 5.7 8.49.2 / 3.0 11.6 / 3.9 14.5 / 4.8 6.3 8.020 / 16 32 / 16 32 / 16 - / 16 - / 20
RWM 4.0FSN3E RWM 5.0FSN3E RWM 6.0FSN3E RWM 8.0FSN3E RWM 10.0FSN3E
RWM 4.0HFSN3E RWM 5.0HFSN3E RWM 6.0HFSN3E RWM 8.0HFSN3E RWM 10.0HFSN3E
9.8 (4.8 ~ 13.5) 12.0 (6.3 ~ 16.3) 14.0 (5.9 ~ 17.8) 19.6 (11.3 ~ 25.5) 24.0 (11.6 ~ 32.0)
4.47 4.36 4.11 4.45 4.41
9.2 (4.5 ~ 12.5) 11.3 (5.6 ~ 15.5) 13.3 (5.6 ~ 16.5) 18.4 (10.6 ~ 24.5) 22.6 (10.9 ~ 31.0)
3.42 3.16 3.01 3.43 3.40
8.1 (4.0 ~ 10.0) 10.1 (5.1 ~ 13.7) 12.6 (5.4 ~ 13.9) 16.2 (9.3 ~ 20.5) 20.2 (9.8 ~ 27.4)
2.59 2.60 2.47 2.70 2.67
7.6 (2.9 ~ 9.8) 9.0 (3.3 ~ 11.5) 9.4 (3.5 ~ 12.0) 14.8 (8.8 ~ 17.8) 18.0 (8.9 ~ 21.6)
2.42 2.40 2.34 2.63 2.61
7.1 (2.8 ~ 8.5) 8.3 (3.1 ~ 10.2) 8.7 (3.2 ~ 10.4) 14.2 (8.4 ~ 16.6) 16.6 (8.2 ~ 20.4)
2.14 1.92 1.81 2.17 2.16
5.9 (2.4 ~ 6.3) 7.7 (2.9 ~ 8.7) 7.9 (3.0 ~ 8.9) 11.8 (7.0 ~ 12.6) 15.4 (7.6 ~ 17.7)
1.55 1.55 1.46 1.73 1.72
7.2 (2.6 ~ 8.2) 9.2 (3.3 ~ 10.3) 10.5 (3.1 ~ 11.5) 14.4 (6.7 ~ 16.4) 18.4 (6.4 ~ 20.6)
3.06 3.03 2.61 3.53 3.12
10.0 (3.6 ~ 11.2) 12.9 (4.7 ~ 15.0) 15.0 (4.4 ~ 17.8) 20.0 (9.3 ~ 23.5) 24.5 (8.6 ~ 29.0)
3.88 4.02 3.50 4.43 3.57
1.7 (1.0 ~ 3.3) 2.1 (1.1 ~ 3.6) 2.4 (1.2 ~ 3.6) 3.4 (2.0 ~ 4.7) 4.1 (2.2 ~ 4.8)38 46 55 76 9228 28 28 29 29
890 890520 670360 360
59 61 61 81 85G 1-1/4" (male) G 1-1/4" (male) G 1-1/4" (male) G 1-1/4" (male) G 1-1/4" (male)
130 140 140 250 2602.0/4.0/6.0 2.0/4.0/6.0 2.0/4.0/6.0 3.0/6.0/9.0 3.0/6.0/9.0
White (RAL 9016)
1Ph 220-240V 50Hz or 3Ph 380-415V 50Hz- -
3Ph 380-415V 50Hz26.7 / 9.3 26.7 / 9.3 26.7 / 9.3 - / 14.1 - / 14.2
40 / 16 40 / 16 40 / 16 - / 20 - / 20
For full technical details, refer to Technical Manualhitachiheating.com Email: [email protected]: 01628 585 394
Domestic Heating
Yutaki Accessories
Model Code Range
Controller Pack Yutaki-M - (A(V)HN / A(V)HN-HM) Controller Pack - Controller + Room Thermostat (55ºC machine)
ATW-CPA-01 Controller CP60 Yutaki-M - (A(V)HN1) Controller Pack CP60 Controller + Room Thermostat (60ºC machine)
ATW-CPA-02 Yutaki-M - (A(V)HN1) Advanced Controller + Room Thermostat (60ºC machine) (check availability)
ATW-RTU-01 Yutaki-S (RWM - FSN3E) On/Off Thermostat (Receiver + Room Thermostat)
ATW-RTU-02 Yutaki-S (RWM - FSN3E) Intelligent Thermostat (Receiver + Room Thermostat)
ATW-RTU-03 Yutaki-S (RWM - FSN3E) 2nd Temp Thermostat, only RTU-02 (Only Room Thermostat)
RHM-EH01E Yutaki-M - (All Models) Hydraulic Module - Electric Heater inc Control Pack
RHM-BC01E Yutaki-M - (All Models) Hydraulic Module - Boiler Combination inc Control Pack
ATW-PK-01 Yutaki-M - (A(V)HN1) Pump Kit (Top-S 25/7)
ATW-PK2-01 Yutaki-M - (A(V)HN1) Pump Kit (Top-S 25/10)
ATW-PK3-01 Yutaki-M - (A(V)HN1) Pump Kit (Top-S 25-70/180)
Pump Kit A (small) Yutaki-M - (A(V)HN / A(V)HN-HM) Pump Kit A
Pump Kit B (big) Yutaki-M - (A(V)HN / A(V)HN-HM) Pump Kit B
ATW-WCV-01 Yutaki-M - (All Models) Water Check Valve
WEH-6E Yutaki-M - (All Models) Both 1Ø & 3Ø Electric Heater 6kW - (2/4/6kW stages)
ATW-HSK-01 Yutaki-M/S Hydraulic Separator
ATW-3WV-01 Yutaki-M/S 3-Way Valve
ATW-2KT-01 Yutaki-M/S 2nd Zone Temperature Kit
ATW-AQT-01 Yutaki-M/S Aquastat
ATW-WTS-02Y Yutaki-M/S Water Temperature Sensor for Hot Water Tank (included with HAPE Tank)
DBS-26 Yutaki-M/S Drain Boss Kit
ATW-MVM-01 Yutaki-S (RWM - FSN3E) Mixing valve motor
ATW-DPK-01 Yutaki-S (RWM - 2.0~6.0FSN3E) Drain Pan Kit for RWM
ATW-DPK-02 Yutaki-S (RWM - 8 ~ 10FSN3E) Drain Pan Kit for RWM
ATW-AOS-01 Yutaki-S (RWM - FSN3E) Auxiliary output signal box
ATW-20S-01 Yutaki-S (RWM - FSN3E) 2nd Outdoor Temperature Sensor
ATW-WTS-02 Yutaki-S (RWM - FSN3E) Water Temperature Sensor (2nd Temp control, boiler combination)
ATW-SPS-01 Yutaki-S (RWM - FSN3E) Swimming Pool Sensor
DHWT200E - 2.5H1E Yutaki-M/S 200L Enamelled Tank inc. 2.5kW electric heater
DHWT300E - 2.5H1E Yutaki-M/S 300L Enamelled Tank inc. 2.5kW electric heater
DHWT200S - 2.5H1E Yutaki-M/S 200L Stainless Steel Tank inc. 2.5kW electric heater
DHWT300S - 2.5H1E Yutaki-M/S 300L Stainless Steel Tank inc. 2.5kW electric heater
DHWT-CP-01 Yutaki-M/S Permanent cathode protection for enamelled tank 200L
DHWT-CP-02 Yutaki-M/S Permanent cathode protection for stainless steel tank 200L
DHWT-CP-03 Yutaki-M/S Permanent cathode protection for enamelled tank 300L
DHWT-CP-04 Yutaki-M/S Permanent cathode protection for stainless steel tank 300L
DHWT-SWG-01 Yutaki-M/S Safety valves
For full technical details, refer to Technical Manual
1
2
3
4
5
6
7
8
9
10
11
12
13
15
11
16
17
18
14
Hitachi Product Catalogue | 83
Yutaki Accessories
Domestic Heating
1 32 4 5
6 7 8 9 10
15 16 17 18
11 12 13 14
For full technical details, refer to Technical Manualhitachiheating.com Email: [email protected]: 01628 585 394
Features and Benefits
Samurai Chillers
Hitachi Samurai Chillers offer world-renowned reliability thanks to Hitachi’s twin screw compressors.
Unlike some competitors, Hitachi manufactures the compressors and was, in fact, the world’s first
supplier of screw chiller units.
All Samurai Chillers
110~1030kW - available with heat recovery option – and Heat Pump models from 120~600kW
energy saving over step control
Hitachi uses high technology to achieve the lowest sound. The adoption of DC Inverter twin blade fans, rather than four, achieves a reduction of noise level. Low noise and super low noise models are available
independent of cooling load
maximum starting current
reliable with very low noise and vibration
Due to the meticulous design of each and every component, it is possible to achieve exceptionally high cooling capacity values per square metre.
Hydraulic Module Option - Single and Dual Pump Models
Hitachi Hydraulic modules are a compact design integrated inside the Chiller unit. They are assembled with all interconnecting piping and wiring during manufacture ready for installation.
Available for Air-Cooled Cooling Only RCU2E(40~80)AG2 and Air Cooled Heat Pump RHU2E(40~80)AG2 models. Available with single or dual pumps and with or without a buffer tank.
Other options available, please contact your local sales office.
Hitachi Product Catalogue | 85
Samurai Air Cooled Cooling OnlyRCU2E 40~400AG2
Air Cooled Heat PumpRHU2E 40~240AG2
Water CooledRCUE 40~240WG2
Condenserless Cooling OnlyRCUE 40~120CLG2
Nominal Cooling Capacity (kW) 112 ~ 1030 106 ~ 585 134 ~ 696 120 ~ 360
Nominal Heating Capacity (kW) - 110 ~ 556 161 ~ 824 -
Refrigerant R407C R407C R407C R407C
Compressor Type Screw Screw Screw Screw
Operating Range (Cooling) (-15ºC ~ 46ºC)db (-15ºC ~ 46ºC)db - -
Operating Range (Heating) - (-15ºC ~ 15.5ºC)db - -
No. Circuits 1 ~ 5 1 ~ 3 1 ~ 3 1 ~ 2
Samurai Chillers
Air Cooled Cooling Only
RHU2E 40AG2
RHU2E 50AG2
RHU2E 60AG2
RHU2E 70AG2
RHU2E 80AG2
RHU2E 100AG2
RHU2E 120AG2
RHU2E 140AG2
RHU2E 160AG2
RHU2E 180AG2
RHU2E 210AG2
RHU2E 240AG2
Cooling Capacity1 kW 106 123 148 169 195 246 296 338 390 444 507 585Heating Capacity2 kW 110 127 152 185 185 254 304 370 370 456 555 555Power Input (Cooling) kW 37.9 42.7 52 60 70 85.4 104 120 140 156 180 210Power Input (Heating) kW 40.7 44.5 54 68 68 89 108 136 136 162 204 204EER 2.8 2.88 2.85 2.82 2.79 2.88 2.85 2.82 2.79 2.85 2.82 2.79COP 2.7 2.85 2.81 2.72 2.72 2.85 2.81 2.72 2.72 2.81 2.72 2.72ESEER 3.36 3.45 3.42 3.38 3.34 3.45 3.42 3.38 3.34 3.42 3.38 3.34
Sound Power Level (Std/LN/SLN)
dB(A)82/80/78 83/81/79 84/82/80 85/83/81 85/83/81 86/84/82 87/85/83 88/86/84 88/86/84 89/87/85 91/89/87 91/89/87
Sound Pressure Level (Std/LN/SLN)3
dB(A)52/50/48 53/51/49 54/52/50 55/53/51 55/53/51 55/53/51 56/54/52 57/55/53 57/55/53 57/55/53 58/56/54 58/56/54
Height mm 2430Width mm 1900Depth mm 2190 2790 4090 5290 5990 7790Net Weight kg 1550 1600 1670 1880 1950 3050 3250 3670 3780 4780 5440 5650
Capacity Control- Continuous Capacity Control% 15 ~ 100
Number of Circuits - 1 1 1 1 1 2 2 2 2 3 3 3
Water Pipe Connectionin 3” Victaulic (1 x Inlet / 1 x Outlet) per Circuitin - Common Water Pipe Connection Option available
Leaving Water Outlet Temperature (Cool)
°C 5 ~ 15 (-10 option)
Leaving Water Outlet Temperature (Heat)
°C 35 ~ 55
Ambient Temperature °C -15 ~ 46 Cooling / -10 ~ 15.5wb Heating
Air Cooled Heat Pump
NOTES: Please refer to notes 1 and 3
RCU2E 40AG2
RCU2E 50AG2
RCU2E 60AG2
RCU2E 70AG2
RCU2E 80AG2
RCU2E 100AG2
RCU2E 120AG2
RCU2E 140AG2
RCU2E 160AG2
RCU2E 180AG2
RCU2E 210AG2
RCU2E 240AG2
RCU2E 280AG2
RCU2E 320AG2
RCU2E 350AG2
RCU2E 400AG2
Cooling Capacity1 kW 112 130 156 178 206 260 312 356 412 468 534 618 712 824 890 1030Power Input kW 38.6 44.7 53 61 70 89.4 106 122 140 159 183 210 244 280 305 350EER 2.9 2.91 2.94 2.92 2.94 2.91 2.94 2.92 2.94 2.94 2.92 2.94 2.92 2.94 2.92 2.94ESEER 3.48 3.49 3.52 3.5 3.52 3.49 3.52 3.5 3.52 3.52 3.5 3.52 3.5 3.52 3.5 3.52
Sound Power Level (Std/LN/SLN)
dB(A)82/80/78 83/81/79 84/82/80 85/83/81 85/83/81 86/84/82 87/85/83 88/86/84 88/86/84 89/87/85 91/89/87 91/89/87 92/90/88 92/90/88 94/92/90 94/92/90
Sound Pressure Level (Std/LN/SLN)3
dB(A)52/50/48 53/51/49 54/52/50 55/53/51 55/53/51 55/53/51 56/54/52 57/55/53 57/55/53 57/55/53 58/56/54 58/56/54 59/57/55 59/57/55 60/58/56 60/58/56
Height mm 2430Width mm 1900Depth mm 2190 2790 4090 5290 5990 7790 10290 12790Net Weight kg 1430 1470 1560 1760 1820 2830 3000 3420 3550 4450 5070 5250 6750 7000 8450 8750Capacity Control % 15 ~ 100Number of Circuits - 1 1 1 1 1 2 2 2 2 3 3 3 4 4 5 5
Water Pipe Connection
in 3” Victaulic (1 x Inlet / 1 x Outlet) per Circuitin - Common Water Pipe Connection Option available
Leaving Water Outlet Temperature
°C 5 ~ 15 (-10 option)
Ambient Temperature °C -15 ~ 46
NOTES: Please refer to notes 1, 2 and 3
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 87
Samurai Chillers
Water Cooled
RCUE 40WG2
RCUE 50WG2
RCUE 60WG2
RCUE 80WG2
RCUE 100WG2
RCUE 120WG2
RCUE 150WG2
RCUE 180WG2
RCUE 200WG2
RCUE 240WG2
Cooling Capacity4 kW 134 160 194 232 320 388 445 525 600 696Heating Capacity5 kW 161.1 192.3 233.9 274.7 384.7 467.9 526.9 621.9 719.5 824.2Power Input (Cooling)4 kW 33.5 40 49.1 54.5 80 98.2 104.5 123.5 148.5 163.5Power Input (Heating)5 kW 39.8 47.5 58.3 64.7 95 116.6 124.1 146.7 176.4 194.2EER 4.0 4.0 4.0 4.3 4.0 4.0 4.3 4.3 4.0 4.3COP 4.0 4.0 4.0 4.2 4.0 4.0 4.2 4.2 4.1 4.2ESEER 4.52 4.52 4.46 4.81 4.52 4.46 4.83 4.82 4.55 4.82Sound Power Level dB(A) 83 84 86 86 88 90 90 91 92 93Sound Pressure Level dB(A) 68 69 71 71 72 74 74 75 76 77Height mm 1520 1700 1580Width mm 1105Depth mm 850 1465 2350Net Weight kg 750 765 830 950 1570 1670 1770 2500 2580 2670
Capacity Control- Continuous Capacity Control% 15 ~ 100
Number of Circuits - 1 1 1 1 2 2 2 3 3 3
Water Pipe Connection (Evaporator)
in 3” Victaulic (1 x Inlet / 1 x Outlet) 3” Victaulic (3 x Inlet / 3 x Outlet)in - 5” Victaulic (1 x Inlet / 1 x Outlet)
Water Pipe Connection (Condenser)
in 3” Victaulic (1 x Inlet / 1 x Outlet) 3” Victaulic (3 x Inlet / 3 x Outlet)in - 5” Victaulic (1 x Inlet / 1 x Outlet)
Leaving Water Outlet Temperature (Cool) °C 5 ~ 15 (-10 option)
Leaving Water Outlet Temperature (Heat) °C 25 ~ 55
Condenser Water Outlet Temprature7 °C 22 ~ 45 (55* option)
RCUE 40CLG2
RCUE 50CLG2
RCUE 60CLG2
RCUE 80CLG2
RCUE 100CLG2
RCUE 120CLG2
Cooling Capacity6 kW 120 145 180 240 290 360Power Input kW 34.4 42.4 52.1 68.8 84.8 104.2EER 3.5 3.4 3.5 3.5 3.4 3.5ESEER 4.32 4.32 4.28 4.32 4.23 4.28Sound Power Level dB(A) 83 84 86 86 88 90Sound Pressure Level dB(A) 68 69 71 71 72 74Height mm 1520 1720Width mm 1045 1104Depth mm 885 1471Net Weight kg 630 680 730 1200 1310 1380
Capacity Control- Continuous Capacity Control% 15 ~ 100
Number of Circuits - 1 1 1 2 2 2Water Pipe Connection (Evaporator) in 3” Victaulic (1 x Inlet / 1 x Outlet)
Leaving Water Outlet Temperature °C 5 ~ 15 (-10 option)
Condensing Temperature °C 30 ~ 65
Condenserless Cooling Only
NOTES: Please refer to notes 4 and 5. 7 ( ) is in case of high condensing option and heat pump operation option.
NOTES: Please refer to note 6
NOTES:
1. The nominal cooling capacities are based on the European Standard EN14511.
Chilled Water Inlet / Outlet Temperature: 12 / 7°C Condenser Inlet Air Temperature: 35°C
2. The nominal heating capacities are based on the European Standard EN14511.
Heated Water Inlet / Outlet Temperature: 40 / 45°C Evaporator Air Inlet Temperature: 6°C wb
3. Sound Pressure level measured at 10m
4. The nominal cooling capacities are based on the European Standard EN12055.
Chilled Water Inlet / Outlet Temperature: 12 / 7°C Cooling Water Inlet / Outlet Temperature: 30 / 35°C
5. The nominal heating capacities are only for Heat Pump Operation Option and based on following conditions.
Chilled Water Inlet / Outlet Temperature: 12 / 7°C Hot Water (Condenser) Inlet / Outlet Temperature: 40 / 45°C
6. The nominal cooling capacities are based on the following conditions.
Chilled Water Inlet / Outlet Temperature: 12 / 7°C Condensing Temperature: 45°C
hitachiaircon.com Email: [email protected]: 01628 585 394
Features and Benefits
Control Systems and Accessories
H-LINK II
H-LINK II across the entire Hitachi product range means you can use Hitachi System Free controls for any mix of products.
CS Net Web
Hitachi’s CS Net Web is a standalone control system that allows users to fully monitor and control their air conditioning from anywhere with web access. Single and multiple sites can be monitored from one central point and the user can ascertain the system performance at all times.
CS Net Web can control up to 512 indoor units and up to 64 outdoor units connected to the H-LINK communication system.
Optional touchscreen
Hitachi’s touchscreen allows intuitive control of up to four CS Net Web central controllers. It can be fixed to either a wall or table using the supplied mounting bracket.
BMS Interfaces
BMS interfacing options are compatible with the Utopia, Set Free and Samurai Chiller ranges allowing the connection of Hitachi H-LINK air conditioning units to building management systems using Modbus, BacNet, KNX and LonWorks® protocols.
ModBusInterface to allow a ModBus compatible building management system to control and monitor up to 32 H-LINK compatible indoor units, or up to eight Samurai Chillers via a RS485 connection. Up to eight controllers can be connected to one H-LINK communications circuit.
KNXInterface to allow a KNX compatible building management system to control and monitor up to 16 H-LINK compatible indoor units. This unit is an accessory for the CS Net Web central controller and connects to the BMS system via a KNX-TP1 type connection.
HARC BX (A/B) LonWorks®
Interface to allow a LonWorks® compatible building management system to control and monitor up to 64 (option A) or 32 (option B) H-LINK compatible indoor units.
BMS interface HARC70-CE1/OP LonWorks®
Interface to allow integration of Hitachi H-LINK and LonWorks® BMS systems. Two options are available dependent on the level of control required.
BACNetInterface to allow a BACNet compatible building management system to control and monitor up to 64 H-LINK compatible indoor units via the BACNet/IP protocol.
Hitachi Product Catalogue | 89
Control Systems and Accessories
Individual Controls
Group Controls
RAC Controls
SPX-RCK3 Wired Remote Controller - WX8, FH6, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8
SPX-RCK2 Wireless Remote Controller & Receiver Kit - RAD-NH7A
SPX-WKT1 Wired Remote Controller + 7 Day Timer - WX8, FH6, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8
SPX-DST1 Optional Distributor Kit for SPK-WKT1 (centralised control of up to 13 indoor units)
SPX-WDST8M Optional wiring kit for SPX-WKT1 & SPX-DST1
PSC-6RAD H-LINK Adapter connects RAC models: WX8, FH6, YH7, YH5A, NH5A, NH7A, FX8, NX2 and QH8 to H-LINK
System Free Controls
PC-ART Std. Wired Remote Controller (inc 7 Day Time Clock) (System Free Indoor Units)
PC-ARF Wired LED Controller with advanced graphical interface (inc 7 Day Time Clock) (System Free Indoor Units)
PC-ARH Simple Wired Remote Controller - (System Free Indoor Units)
PC-LH3A Wireless Remote Controller - Receiver kit required (inc. with RPK-FSN2M)
PC-ALHN Receiver Kit panel mounted (RCI-FSN3E)
PC-ALHD Receiver Kit panel mounted (RCD-FSN3E)
PC-ALHC Receiver Kit panel mounted (RCIM-FSN3E)
PC-ALHZ Receiver Kit wall mounted (All System Free Indoor Units)
Group Controls
PSC-A64GT Touchscreen Central Controller (64 Groups, 160 Units - System Free)
PSC-A64S Central Controller (64 Groups, 160 Units - System Free)
CSC 5S Central Controller - (up to eight Samurai Chillers)
PSC-A1T 7 Day Timer
CS Net Web (v3.0) Web based Control, Stand alone or with Touchscreen below (64 outdoor units, 512 indoor units)
TS002 Touchscreen for CS Net Web
PC-A1IO Control/Monitor 3rd party equipment via CS Net Web
PSC-5HR H-LINK Relay - extend H-LINK wiring up to maximum 1,000m
BMS Interface Controls
HC-A32MB ModBus Interface, control/monitor 32 System Free indoor units or 8 Samurai Chillers
HARC-BX (A/B) LonWorks® Interface, control/monitor 64(A) or 32(B) System Free indoor units
HARC-70CE1 (OP) LonWorks® Interface, control/monitor up to 4 Samurai Chillers
HC-A16KNX KNX Interface, control/monitor 16 System Free indoor units
HC-A64BNP BACNet Interface, control/monitor 64 System Free indoor units
SPX-RCK3
SPX-WKT1
SPX-RCK2
PC-ART
PCS-A64GT
PC-ARH
PC-ARF
PSC-A64S CS Net Web
PSC-A1T
Touchscreen
BMS Interface Controls
For full technical details, refer to Technical Manual
Control Systems and Accessories
Hitachi Product Catalogue | 91
For full technical details, refer to Technical Manual
S Y S T E MFREE
Accessories
PCC1A Optional Function Connector Cables (pack of 5) - Utopia and Set Free
THM-R2AE Remote Sensor
PDF-23C3 Side Duct Connection Flange (RCI 1.0~3.0FSN3E)
PDF-46C3 Side Duct Connection Flange (RCI 4.0~6.0FSN3E)
PD-75 Fresh Air Intake Kit, 75mm dia (RCI 1.0~6.0FSN3E)
PI 23LS5 Cassette 3-Way outlet kit
DBS 26 Drain Boss Kit (All Outdoor Units except below)
DBS 12L Drain Boss Kit (RAS 2.0 ~ 2.5HVRN2 + RAS 3.0HVRNS2)
DBS-TP10A Drain Boss Kit (RAS-FSXN)
DU M1E Drain Pump Kit (RPIM-FSN2E)
PCC1A
DBS 26
PD-75
DBS 12L
THM-R2AE
DU M1E
Accessories
Pipe Kits (Utopia ES, IVX, Centrifugal)
TE-03N Twin Pipe Kit (3HP System)
TE-04N Twin Pipe Kit (4HP System)
TE-56N Twin Pipe Kit (5 & 6HP System)
TE-08N Twin Pipe Kit (8HP System)
TE-10N Twin Pipe Kit (10 & 12HP System)
TRE-06N Triple Pipe Kit (4 ~ 6HP System)
TRE-810N Triple Pipe Kit (8 ~ 12HP System)
QE-810N Quad Pipe Kit (8 ~ 12HP System)
E-102SN2 Piping Kit (Only use with 8 ~ 12HP IVX)
E-162SN2 Piping Kit (Only use with 8 ~ 12HP IVX)
Pipe Kits (Set Free - Mini, Side Flow, Modular)
E-102SN2 Piping Kit (Only use with 8 ~ 12HP IVX)
E-162SN2 Piping Kit (Only use with 8 ~ 12HP IVX)
E 242SN2 Pipe Kit (2-pipe)
E 302SN2 Pipe Kit (2-pipe)
E 52XN2 Pipe Kit (3-pipe)
E 102XN2 Pipe Kit (3-pipe)
E 162XN2 Pipe Kit (3-pipe)
E 202XN2 Pipe Kit (3-pipe)
E 242XN2 Pipe Kit (3-pipe)
E 322XN2 Pipe Kit (3-pipe)
MH 84AN Pipe Kit (2-pipe header)
MH 108AN Pipe Kit (2-pipe header)
MH 108XN Pipe Kit (3-pipe header)
MC 20AN Modular Set Free 2-pipe Branch Kit (RAS 20~24FSXN)
MC 21AN Modular Set Free 2-pipe Branch Kit (RAS 26~36FSXN)
MC 30AN Modular Set Free 2-pipe Branch Kit (RAS 28~54FSXN)
MC 20XN Modular Set Free 3-pipe Branch Kit (RAS 20~24FSXN)
MC 21XN Modular Set Free 3-pipe Branch Kit (RAS 26~36FSXN)
MC 30XN Modular Set Free 3-pipe Branch Kit (RAS 28~54FSXN)
Pipe Kits
hitachiaircon.com Email: [email protected]: 01628 585 394
For full details, refer to Technical Manual
Helping YouDirect Sales (UK)
T: 01628 585 394
Spares
T: 01628 585 394
hitachiairco
n.com/spareparts
Technical (UK)T: 01628 585 393
Technical and Service Manuals available athitachiaircon.com
Proactively meeting the expectations of our customers through continuous innovation
Download our latest
selection (HiToolkit)
software at
hitachiaircon.com
Hitachi Product Catalogue | 93
Direct Sales (Ireland)E: [email protected]: 00 353 1216 4406
ApplicationsE: [email protected]
T: 01628 585 394
TrainingE: [email protected]: 01628 585 394
WarrantyE: [email protected]
T: 01628 585 393
hitachiaircon.com/warranty
24-hour alarm codesT: 01628 585 393 (option 2) or visit hitachiaircon.com to download our new alarm codes App
Technical (Ireland)
T: 00 353 1296 8065
Technical and Service
Manuals available at
hitachiaircon.com
Hitachi’s Training Centre
Helping you increase your technical and product knowledgeHitachi offer high-quality training courses in its aircademy training centre based at Hitachi Europe Headquarters in Maidenhead, Berkshire. This newly-refurbished centre is dedicated to excellence and a wide range of Hitachi air conditioning and refrigeration products are displayed.
The equipment is fully operational and used extensively throughout all training courses allowing Hitachi to offer practical, hands-on experience to attendees.
All training is given by highly-skilled engineers with vast industry experience and an in-depth knowledge of Hitachi products. If you have any specific training requests please contact us and our engineers will be happy to tailor a course to suit your needs.Contact [email protected]
Product training coursesHitachi’s one-day product-specific training courses are provided FREE OF CHARGE.
Lunch included.
Morning 09.45-12.45 Afternoon 13.30-17.00
Mechanical and electrical coursesMechanical and electrical training courses, such as basic refrigeration and air conditioning, safe handling of refrigerants, IEE wiring regulations, electrical inspection and essential electrics are available with an external partner upon request. All courses provide CITB or City and Guilds qualifications upon completion.
set up
up demonstration
connecting to LAN
CS Net Web for the Field Engineer
design and application
and control wiring
and operation
(Yutaki S)
Yutaki Air to Water Heat Pump for the Field Engineer
demonstration
Set Free and Utopia Selection and Design
Samurai Selection and Design
and installation
and control wiring
and operation
and operation
and system set up
and system interrogation
interfacing overview
Samurai Chillers for the Field Engineer
Set Free VRF and Utopia Inverter Splits for the Field Engineer
design and installation
control wiring
and operation
interfacing overview
Room Air Conditioners for the Field Engineer
pipe work design and installation
and control wiring
system interrogation
interfacing overview
and operation
Hitachi Price List | 95
ContactT: 01628 585394
F: 01628 585500
Every precaution has been taken during the design and manufacture of Hitachi Air Conditioning equipment to ensure the products conform to the highest standards. In the event of a warranty fault the owner should advise the original installer. The following sets out the current Hitachi Air Conditioning Europe SAS warranty policy.
For all RAC products the warranty period shall be for 36 months (3 years) from date of invoice.
For all Utopia and Set Free the warranty period shall be 60 months (5 years) from date of invoice**.
For all Samurai Chillers the warranty period shall be 36 months (3 Years) from the date of invoice.
For all Central Control Systems the warranty period shall be 36 months (3 years) from the date of invoice.
®
period for the applicable indoor unit.
For all spare parts, the warranty period shall be 12 months parts only.
Warranty
All components requested to be returned should be sent to Hitachi Air Conditioning Europe SAS (Warranty Department) Whitebrook Park, Lower Cookham Road, Maidenhead, SL6 8YA clearly marked with the Warranty number. Components returned without a valid Warranty number will not be accepted.
Within the above specified time periods, all products are guaranteed against manufacturing faults in workmanship and material. The faulty component will be replaced free of charge provided the correct procedures are complied with and a labour contribution can be claimed during the first 3 years***, the amounts of which are laid out on next page.
The warranty policies are subject to the following conditions.
The Hitachi Air Conditioning Europe SAS equipment is installed using the correct working practices, and installed within the parameters set out in the technical manuals for each unit, and maintained regularly (minimum of every 6 months, site dependant, by a qualified installer) in accordance with the manufacturer’s recommendations.
Placing a claim Place your claim online
Contact the warranty department on 01628 585 393, and ask for your secure login to be set up and place your warranty claim online at hitachiaircon.com/warranty
You can then track the progress of your claim “live” online, and gain access to tracking and despatch details and receive email notification of your warranty progression.
If any of the information is not available at the time of claim, then the part can be ordered via an official purchase order and a credit arranged retrospectively, when all the information is available. (This must be within 60 days of the original date of failure).
All warranty claims must be made within 60 days of failure. Any claim submitted after the 60 day period WILL NOT be considered for approval.
Parts should be held by the customer for a period of 30 days during which time if required, Hitachi Air Conditioning Europe SAS can request the return of the parts at our cost for inspection and a RMA number will be issued. If it is deemed to have failed “out of warranty” the part will be invoiced to the customer at our standard spare parts rate.
Repeat warranty requests will be subject to Hitachi Air Conditioning Europe SAS investigation and possible site visit. An official purchase order will be required to purchase the part, pending a decision on the validity of the claim. All parts will be inspected within 14 days, and a credit issued if the warranty is accepted. For warranty claims rejected following inspection, the part will be returned and invoiced to the customer at our standard spare
Normal wear and tear is excluded.
Any claim not submitted in accordance with Hitachi Air Conditioning Europe SAS procedures WILL NOT be considered for credit.
* Approved combinations only.
** Subject to Hitachi Air Conditioning Europe SAS assisting with the commissioning, and commissioning reports being logged with ourselves. Failure to comply will result in the warranty reverting to 36 months (3 years) parts and labour contribution.
For a wallet-sized list of alarm codes for RAC, Set Free VRF and Utopia Split Systems
Contact [email protected] to request a copy
Or visit hitachiaircon.com to download our new alarm codes App
AndroidScan this QR Code using your Android phone to download our new alarm codes App
iPhone - iOSScan this QR Code using your iPhone - iOS phone to download our new alarm codes App
Hitachi Product Catalogue | 97
Alarm Codes
Alarm Codes for
Indoor unit faults
Flashing TIMER lamp
Main cause
1 time the heating mode or it is too high in the cooling mode
2 times
3 times
4 times
5 times
6 times Drain high level water alarm
7 times Drain pump forced operation
8 times Louver defective
9 times
10 times Fan motor overload
11 times High voltage generator fault
12 times
13 times
17 times
18 times Cleaning unit defect
19 times Failure of peltier device
Flashing CLEAN lamp
Main cause
1 time Front cover is open
4 times Failure of the cleaning unit motor or detection switch
Flashing MONITOR lamp
Main cause
1 time Front cover is open
4 times
Outdoor unit faults
Flashing LD 301 Main cause
1 time Normal operation
2 times Compressor overload
3 times Low compressor rotation
4 times Compressor switching failure
5 times
6 times Compressor over temperature alarm
7 times Faulty thermistor (check LD 303 to identify which one)
8 times
9 timesCommunication alarm
10 times
12 times Fan alarm
13 times Eeprom error
14 times
Flashing LD 304 Main cause
1 time Communication error
Flashing LD 303 Main cause
1 time
2 times Defrost thermistor
3 times
4 times
5 times Suction line thermistor (Unit 1)
6 times
7 times Suction line thermistor (Unit 2)
8 times
9 times Suction line thermistor (Unit 3)
10 times
11 times Suction line thermistor (Unit 4)
12 times
13 times Suction line thermistor (Unit 5)
Alarm Codes
Hitachi Product Catalogue | 99
For full technical details, refer to Technical Manual
Alarm Codes for
remote control switch.
service provider.
Alarm Code
Alarm Code
Alternate indication every second
Indoor unit number
Model code
Number of indoor units connected
Model Code
Indication Model
H Heat Pump
P Inverter
F Multi
C Cooling Unit
E Others
L KPI
Code No. Category Type of Abnormality Main cause
01 Indoor unit Protection device activation (float switch) Float switch activation (high water level in drain pan. Blockage in drain pipe, float switch activated or drain pump faulty)
02 Outdoor unit Protection device activationHP switch activation (pipe blocked, excess refrigerant, non condensable present). Phase loss or incorrect rotation (Utopia only), float switch activation or MT open circuit (Centrifugal unit only)
03 Transmission Abnormality between indoor and outdoor communication
Incorrect wiring, loose terminals, disconnect cable, blown fuse, outdoor unit switched off. Incorrect address setting
04 Transmission Abnormality between inverter PCB and outdoor PCB
Inverter PCB - Outdoor PCB transmission fault (loose connector, broken cable, blown fuse)
Transmission Abnormality between fan controller and outdoor PCB
Fan controller - Outdoor PCB transmission fault (loose connector, broken cable, blown fuse)
05 Power phase Abnormality in the power phases Incorrect power supply, inverted phase connection, open phase
06 Voltage Abnormal inverter voltage Abnormal inverter controller voltage
Outdoor voltage drop, insufficient power. Capacitor or electronic problem on inverter compressor
Voltage Abnormal inverter voltage Abnormal fan controller voltage
Outdoor voltage drop, insufficient power. Capacitor or electronic problem on fan motor
07 Refrigerant Cycle
Drop in discharge gas superheatExcessive refrigerant charge, thermistor fault, incorrect wiring, incorrect pipe connection, expansion valve locked in open position (connector disconnected).
08 Refrigerant Cycle
Increase in discharge gas temperature Insufficient refrigerant charge, blocked pipe, thermistor fault, incorrect wiring, incorrect pipe connection, expansion valve locked in closed position (connector disconnected)
09 Outdoor unit Tripping of protection device Fan motor failure
0A Transmission Abnormality between outdoor and indoor units Incorrect wiring, broken cable, loose terminals
Outdoor unit Incorrect outdoor unit address setting. Main unit of the outdoor unit incorrectly set
Duplicate address setting of outdoor units (secondary units) in the same refrigerant cycle system
0C Outdoor unit Main unit of the outdoor unit incorrectly set Two (or more) outdoor units defined as the “main unit” in the same refrigerant cycle system
11 Indoor unit Air inlet thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
12 Indoor unit Air outlet thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
13 Indoor unit Frost protection thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
14 Indoor unit Gas pipe thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
Alarm Codes for
Alarm Codes
hitachiaircon.com Email: [email protected]: 01628 585 394
Alarm Codes
For full technical details, refer to Technical Manual
Alarm Codes for RAS FSNM
Alarm Codes for
Continued...
Code No. Category Type of Abnormality Main cause
15 Indoor unit Outdoor air thermistor (KPI) Incorrect wiring, disconnected wiring, broken cable, short circuit
16 Indoor unit Remote thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
17 Indoor unit Remote controller thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
19 Fan motor Indoor fan protection device activation Fan motor overheating, locking
20 Outdoor unit Discharge gas thermistor at top of compressor (Utopia)
Incorrect wiring, disconnected wiring, broken cable, short circuit
21 Outdoor unit High pressure sensor Incorrect wiring, disconnected wiring, broken cable, short circuit
22 Outdoor unit Outdoor air thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
23 Outdoor unit Discharge gas thermistor at top of compressor (VRF)
Incorrect wiring, disconnected wiring, broken cable, short circuit
24 Outdoor unit Heat exchanger liquid pipe thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
25 Outdoor unit Heat exchanger gas pipe thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
26 Outdoor unit Suction gas thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
29 Outdoor unit Low pressure sensor Incorrect wiring, disconnected wiring, broken cable, short circuit
31 Outdoor unit Incorrect capacity setting on outdoor and indoor units
Combination capacity incorrectly set. Excessive or insufficient total indoor unit capacity.
32 SystemLoss of communication with 1 indoor unit (Multi system)
Loss of power, Incorrect wiring, loose terminals, disconnect cable, blown fuse, outdoor unit switched off. Incorrect address setting
35 Indoor unit Indoor unit no. incorrectly set Indoor unit no. duplicated in same refrigeration cycle
38 Outdoor unit Abnormality in the control circuit for outdoor unit protection
Protection detection device fault (incorrect wiring of outdoor PCB)
39 Compressor Abnormal operation current in constant speed compressor
Over current, blown fuse, current sensor fault, instant power failure, voltage drop, abnormal power supply or faulty compressor
3A Outdoor unit Abnormal outdoor unit capacity Outdoor unit capacity >54 HP
Outdoor unit Voltage or combination of outdoor unit models incorrectly set
Voltage or combination of secondary and main units incorrectly set
Outdoor unit Abnormal transmission between the main unit and the secondary units
Incorrect wiring, disconnected wiring, broken cable, PCB fault
41 Refrigerant Cycle
Cooling overload (possible activation of high pressure device)
O.U. pipe thermistor temp. is higher than 55 ºC and the compressor top temp. is higher than 95 ºC, O.U. protection device is activated
42 Refrigerant Cycle
Heating overload (high-pressure device may be activated)
If I.U. freeze protection thermistor temp. is higher than 55 and compressor top temp. is higher than 95
44 Refrigerant Cycle
Low-pressure increase protection device activation
Overload during cooling, high temperature with heating, locked expansion valve (loose connector)
45 Refrigerant Cycle
High pressure increase protection device activation
Blocked condenser, pipe blocked, excess refrigerant, non condensable present
47 Refrigerant Cycle
Low-pressure decrease protection device activation (vacuum protection)
"Insufficient refrigerant, refrigerant pipes blocked, expansion valve locked in closed position (VRF). Stoppage due to excessive decrease of evaporating temperature (Temp < -35 ºC) is activated 3 times in one hour, motor locked in heating mode.“
Hitachi Product Catalogue | 101
Alarm Codes
For full technical details, refer to Technical Manual
Alarm Codes for RAS FSNM
Alarm Codes for
Continued...
Code No. Category Type of Abnormality Main cause
48 Inverter compressor
Inverter over current protection device activation
Overload, compressor fault
51 Inverter compressor
Abnormal inverter current sensor Current sensor fault
53 Inverter compressor
Inverter error signal detection Controller IC error signal detection (over current, low-voltage and short-circuit protection)
54 Inverter compressor
Abnormal inverter fin temperature Abnormal inverter fin thermistor, heat exchanger clogging, fan motor fault
55 Inverter compressor
Inverter fault Inverter PCB fault
56 Fan controller
57 Fan controller Fan controller protection activation Controller IC error signal detection (over current, low-voltage and short-circuit protection), instant over current. Abnormal rotation speed
58 Fan controller Fan controller protection activation Controller IC error signal detection (over current, low-voltage and short-circuit protection), instant over current
59 Inverter compressor
Abnormality inverter fin thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
5A Fan controller Abnormal fan controller fin temperature Fin thermistor fault, heat exchanger clogging, fan motor fault
Fan controller Over current protection activation Fan motor fault
5C Fan controller Abnormal fan controller sensor Current sensor fault (instant over current, increased fin temperature, low voltage, earthing fault, step-out)
96 KPI Unit Sensor
Room Temperature thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
97 KPI Unit Sensor
Fresh air thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit
EE SystemCompressor protection alarm (cannot be reset from the remote controller)
This alarm code is displayed when the following alarms are triggered three times within six hours: 02, 07, 08, 39, 43 to 45, 47
Outdoor unit number setting
Unit number or address number of the outdoor unit incorrectly set
A number greater than 64 has been set for the refrigerant cycle or address
Indoor unit number setting
Connection number of the indoor unit incorrectly set
There are more than 17 units not corresponding to H-LINK II connected to one system
C1 CH unit Incorrect indoor unit connection There are 2 or more CH units connected between the outdoor and indoor units
C2 CH unit Connection number of the indoor unit incorrectly set
There are 9 or more indoor units connected to the CH unit
C3 CH unit Incorrect indoor unit connection Indoor units from different refrigerant cycles have been connected to the CH unit
hitachiaircon.com Email: [email protected]: 01628 585 394
Alarm Codes
Alarm Codes for
Checking the 7-Segment display.
SEG.1 SEG.2
8 88 8 8
Upper side
SEG.3 SEG.4 SEG.5
Lower side
Code number Type of Abnormality
8 8 Proceeding Initialisation
8 8p up u8 fh e Heating operation (Normal operation)
h e p o Heating operation (Activation of forced compressor frequency control due to low pressure difference: forced up)
h e p 1 Heating operation (Activation of forced compressor frequency control due to high pressure difference: forced down)
h e p 2h e p 3h e p 4p - 0 6p - 1 1p - 1 2p - 1 7p - 1 8
e 0 (Flickering)
f 8 Fan manual operation
0 2 H 1 Activation of high pressure switch
0 2 h 10 2 L 1 Activation of low pressure control
0 2 e 10 2 6 10 2 9 10 2 E 1
0 40 50 61 1 Failure of water inlet temperature thermistor
1 2 Failure of water outlet temperature thermistor
1 3 Activation of freeze protection control (water inlet)
0 2 1 3 Activation of freeze protection control (water outlet)
1 42 1
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 103
Alarm Codes
Code number Type of Abnormality
2 22 32 42 62 72 83 03 24 05 15 2 Activation of protection for inverter instantaneous over current
5 3 Transistor module protection activation
5 45 75 p6 e6 C
p u (Flickering)
f a Failure of fan motor (MF1)
f 6 Failure of fan motor (MF2)
Alarm Codes for
Continued...
For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394
Alarm Codes
Alarm Code Indication on Remote Control Switch: Alarm indication Alarm code
HITACHI
Code No.
Origin Type of Abnormality Main cause
02 OutdoorActivation of Outdoor Unit Protection Device (Except for Alarm Codes 41, 42)
High-pressure interrupting device activated
03 Outdoor Transmission ErrorOutdoor fuse meltdown, Indoor/outdoor connection wiring (breaking, wiring error, etc.)
04 Outdoor Inverter Transmission AbnormalityControl PCB – Inverter PCB connection wiring (breaking, wiring error, etc.)
05 Outdoor Power Phase Detection Abnormality Power source wiring open phase in Indoor units
06 Outdoor Undervoltage, OvervoltageOutdoor PCB abnormality, inverter PCB abnormality, DM, CB abnormality
07 Outdoor Abnormal Decrease of Discharge Gas Superheat DegreeExcessive refrigerant, expansion valve open-locked, Fan motor locked
08 Outdoor Compressor-Top Temperature Over-IncreaseShortage or leakage of refrigerant, piping clogging, Fan motor locked
11 Indoor Water Inlet Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
12 Indoor Water Outlet Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
13 Indoor Indoor Liquid Pipe Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
14 Indoor Indoor Gas Pipe Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
15 Indoor Water Outlet C2 thermistor Abnormality Loose, disconnected, broken or short-circuited connector
16 Indoor Water DHW Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
17 Indoor Auxiliary Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
18 Indoor Water Outlet Boiler Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
19 Indoor Water Outlet HP Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
20 Outdoor Compressor-Top Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
22 Outdoor Outdoor Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
24 Outdoor Outdoor Heat Exchanger Liquid Pipe Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
31 Outdoor Indoor/Outdoor Combination Setting ErrorOutdoor/Indoor Unit capacity setting error, Indoor total capacity excessively large/small
35 Outdoor Indoor Unit Number Setting ErrorIndoor units with the same number in a refrigerant piping system
Alarm Codes for
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 105
Alarm Codes
Code No.
Origin Type of Abnormality Main cause
38 Outdoor Outdoor Protection Detection Circuit Abnormality Outdoor PCB abnormality, Error in wiring to outdoor PCB
41 Outdoor Cooling OverloadOutdoor heat exchanger clogging/short circuit, Broken outdoor fan motor
42 Outdoor Heating OverloadOutdoor heat exchanger clogging/short circuit, Expansion valve closed-locked
47 Outdoor Suction Pressure Decrease Prevention ActivatedShortage or leakage of refrigerant, pipe clogging, Expansion valve closed-locked, Fan motor locked
48 Outdoor Overload Operation Protection ActivationCycle abnormality, Inverter PCB abnormality, DM abnormality, Heat exchanger clogging, etc.
51 Outdoor Inverter Current Sensor AbnormalityError in CT wiring, Outdoor PCB abnormality, Inverter PCB abnormality
53 Outdoor Inverter Module Error Compressor, ISPM abnormality, Heat exchanger clogging, etc.
54 Outdoor Inverter Fin Temperature AbnormalityFin thermistor abnormality, Heat exchanger clogging, Fan motor abnormality
55 Outdoor Inverter Non-Operation Inverter not operating or broken
56 Outdoor Fan
Fan motor abnormalityDisconnected wire of Incorrect wiring between control PCB and inverter PCB. Incorrect wiring or fan motor abnormality
59 Outdoor Inverter Fin Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector
1 Outdoor Error in Address/Refrigerant System Setting Address/refrigerant system setting over 64
EE Outdoor Compressor Factor AlarmAlarm to notify damage to compressor occurs 3 times within 6 hours
70 Indoor Hydraulic alarm
in the hydraulic cycle
71 Indoor Water Pump Feedback
72 Indoor Thermostat Heater Alarm High temperature is detected in Electric Heater T>75ºC
73 Indoor Mixing overheating limit protection for Mixed circuit Circuit 2 supply temperature > Target temperature + offset
74 Indoor Unit overheating limit protection Two > Tmax +5K
75 IndoorFreeze Protection by Cold water inlet, outlet temperature detection
76 IndoorFreeze Protection Stop by Indoor Liquid Temperature Thermistor
Tl or Tg < -20ºC for 30 seconds (Only heating mode)
77 Indoor Opentherm Communication FailureNo Opentherm communication for a continuous period of 1 minute.
78 Indoor RF Communication FailureNo communication for 1 hour with one or two RF receivers which are bound to the RF-Bridge.
79 Indoor-Outdoor
Unit Capacity Setting Error No concordance between indoor and outdoor unit capacities
80 Indoor LCD
LCD H-link Transmission ErrorNo H-link communication for a continuous period of 1 minute between Indoor and LCD User control by connection wiring (breaking, wiring error, etc.)
Alarm Codes for
Continued...
For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394
For full technical details, refer to Technical Manual
Alarm Codes
Alarm codes for Samurai Chiller
Function of 7-Segment Light Emitted Diode on
SEG.1 SEG.2
8 8 8 8 7 Segments on Control Panel
CodeContentNo. 1
CycleNo. 2 Cycle
No. 3 Cycle
No. 4 Cycle
No. 5 Cycle
C 1 H 1 C 2 H 3 C 3 H 3 C 4 H 4 C 5 H 5 Activation of High Pressure Switch
C 1 L 1 C 2 L 2 C 3 L 3 C 4 L 4 C 5 L 5 Activation of Low Pressure Protection Control
C 1 L 1 C 2 L 2 C 3 L 3 C 4 L 4 C 5 L 5C 1 5 1 C 2 5 2 C 3 5 3 C 5 5 4 C 5 5 5C 1 6 1 C 2 6 2 C 3 6 3 C 4 6 4 C 5 6 5 Activation of Discharge Gas Thermistor
C 1 7 1 C 2 7 2 C 3 7 3 C 4 7 4 C 5 7 5 Activation of Compressor Internal Thermostat
C 1 9 1 C 2 9 2 C 3 9 3 C 4 9 4 C 5 9 5C 1 8 1 C 2 8 2 C 3 8 3 C 4 8 4 C 5 8 5 Activation of Suction Gas Thermistor
C 1 0 5 C 2 0 5 C 3 0 5 C 4 0 5 C 5 0 5C 1 1 2 C 2 1 2 C 3 1 2 C 4 1 2 C 5 1 2C 1 1 3 C 2 1 3 C 4 1 3 C 4 1 3 C 5 1 3 Activation of Freeze Protection Control (More Than 2 Cycle Unit)
C 1 2 1 C 2 2 1 C 3 2 1 C 4 2 1 C 5 2 1C 1 2 3 C 2 2 3 C 3 2 3 C 4 2 3 C 4 2 3C 1 2 4 C 2 2 4 C 3 2 4 C 4 2 4 C 5 2 4C 1 2 5 C 2 2 5 C 3 2 5 C 4 2 5 C 5 2 5C 1 2 6 C 2 2 6 C 3 2 6 C 4 2 6 C 5 2 6C 1 2 7 C 2 2 7 C 3 2 7 C 4 2 7 C 5 2 7C 1 2 8 C 2 2 8 C 3 2 8 C 4 2 8 C 5 2 8C 1 F 0 C 2 F 0 C 3 F 0 C 4 F 0 C 5 F 0F 1 1 1 F 2 1 1 F 3 1 1 F 4 1 1 F 5 1 1F 1 2 1 F 2 2 1 F 3 2 2 F 4 2 2 F 5 2 2F 1 3 1 F 2 3 1 F 3 3 1 F 4 3 1 F 5 3 1F 1 4 1 F 2 4 1 F 3 4 1 F 4 4 1 F 5 4 1F1 51 F2 51 F3 51 F4 51 F5 51
CodeContentNo. 1
CycleNo. 2 Cycle
No. 3 Cycle
No. 4 Cycle
No. 5 Cycle
0 5 0 51 1 1 1 Failure of Water Inlet Temperature Thermistor
1 2 1 21 3 1 3
2 2 2 2S P S P4 0 4 0E U E UF 6 F 6C P C P C1 C2)
“PU”“PU”6 E 6 EA P A P Activation of Additional Protection Device
0 3 0 3F 1 P 7 F 2 P 7 F 3 P 7 F 4 P 7 F 5 P 7F 1 P 8 F 2 P 8 F 3 P 8 F 4 P 8 F 5 P 8C 1 P 5 C 2 P 5 C 3 P 5 C 4 P 5 C 5 P 5C 1 2 8 C 2 2 8 C 3 2 8 C 4 2 8 C 5 2 8C 1 P 6 C 2 P 6 C 3 P 6 C 4 P 6 C 5 P 6
2 1
Self Inspection Functions for Samurai Chiller
Continued...
Normal Indication
CodeContentNo. 1
CycleNo. 2 Cycle
No. 3 Cycle
No. 4 Cycle
No. 5 Cycle
C 1 8 8 C 2 8 8 C 3 8 8 C 4 8 8 C 5 8 8C 1 C 8 C 2 C 8 C 3 C 8 C 4 C 8 C 5 C 8C 1 8 F C 2 8 F C 3 8 F C 4 8 F C 5 8 F
P U P UC 1 C 8 C 2 C 8 C 3 C 8 C 4 C 8 C 5 C 8 Activation of Current Limiter
C 1 E 0 C 2 E 0 C 3 E 0 C 4 E 0 C 5 E 0
For full technical details, refer to Technical Manual
Alarm Codes
Hitachi Product Catalogue | 107
hitachiaircon.com Email: [email protected]: 01628 585 394
For full technical details, refer to Technical Manual
RAC S-Series
Hitachi Product Catalogue | 109
1~/N220-240V / 50Hz
ELB
A B C A B C L1 N
IndoorOutdoor
Key
Mains
Field suppliedisolator
Field suppliedfuse
ELBEarth leakagecircuit breaker
Earth
3 core 1.5mm²shielded
4 core 1.5mm²shielded
Optional wiring
1~/N220-240V / 50Hz
ELB
C
Optionalwired
controller
CN18
DL1 N C D
IndoorOutdoor
RAC Summit < 5.0kW
Optionalwired
controller
CN
18
Optionalwired
controller
CN
18
C1
D1
C1
D1
C2
D2
C3
D3
C2
D2
C3
D3
Optionalwired
controller
CN
18
1~/N220-240V / 50Hz
ELBL1
N
Indoor
Indoor
Indoor
Outdoor
RAC Multizone
1~/N220-240V / 50Hz
ELB
Optionalwired
controller
CN18
L1 N A B C D A B C D
IndoorOutdoor
RAC WX8, Summit > 5.0kW, DH7
Wiring Diagrams
hitachiaircon.com Email: [email protected]: 01628 585 394
For full technical details, refer to Technical Manual
Wiring Diagrams
Key
Field suppliedisolator
Field suppliedfuse
ELBEarth leakagecircuit breaker
Earth
m²2 core 0.75mshielded
Mains
Set Free Mini VRF
Utopia ES, IVX & Centrifugal
For full technical details, refer to Technical Manual
Hitachi Product Catalogue | 111
NL3L2
A B C
L11 2 3 4
ELB
ELB
ELB
L1 N
BA21
3~/N380-415V/50Hz
ELB
1~/N220-240V/50Hz
NL3L2L11 2 3 4
NL3L2L11 2 3 4
L1 N
BA21
ELB
ELB
ELB
L1 N
BA21
L1 N
To next unit
BA21
Indoor
Outdoor
Key
Field suppliedisolator
Field suppliedfuse
ELBEarth leakagecircuit breaker
Earth
m²2 core 0.75mshielded
Mains
Wiring Diagrams
Set Free 2-pipe heat pump
hitachiaircon.com Email: [email protected]: 01628 585 394
For full technical details, refer to Technical Manual
Wiring Diagrams
Key
Field suppliedisolator
Field suppliedfuse
ELBEarth leakagecircuit breaker
Earth
m²2 core 0.75mshielded
Mains
Set Free 3-pipe heat recovery
Hitachi Product Catalogue | 113
DIP Switches
No. of refrigerant cycle (setting for the first digit)
Address of the indoor unit (setting for the first digit)
Address of the indoor unit (setting for the first digit)
No. of refrigerant cycle (setting for the first digit)
DSW5 / DSW10
DSW4 / DSW1
Setting of DIP switches and RSW switches
Notes: 1.Turn off the power supply before setting the DIP switches. Otherwise, the switch settings are invalid.2.To set the position of the RSW rotary switches, insert a screwdriver into the groove of the RSW.
For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394
Conditions of Sale
(7) In the case of the Buyer residing in the United Kingdom, unless otherwise stated, HITACHI will at its own expense deliver to the Buyer’s premises. In the case of exports, unless otherwise stated, delivery will be FOB (Incoterms 2000) at a U.K. port designated by HITACHI.
(8) The delivery by HITACHI of a greater or lesser quantity of the Goods than the quantity provided for in the Contract, the delivery of other goods not provided for in the Contract, or the delivery of the Goods only some of which are defective, shall not entitle the Buyer to reject all of the Goods delivered. In order that HITACHI can comply with its carrier’s conditions any claim in respect of error in quantity or type of Goods or in respect of damage to the Goods in transit must be made in writing to HITACHI and the carrier notified in both cases within 3 days of receipt of the Goods. Failure to make such claim shall constitute unqualified acceptance of the Goods and waiver by the Buyer of all claims relating to error in quantity or type of goods delivered or relating to the condition of Goods delivered. Similarly, if any Goods invoiced by HITACHI are not delivered, in order that HITACHI can claim against its carriers where appropriate the Buyer must notify HITACHI within 10 days of the date of invoice, failing which the Buyer will be liable to pay for the Goods in full. Where liability for error in quantity, or type of Goods or in respect of damage to the Goods in transit is accepted by HITACHI, HITACHI’s only obligation shall be, at its option, to make good any shortage or non-delivery and/or as appropriate to replace or repair any Goods found to be damaged or defective and/or to refund the cost of such Goods to the Buyer.
(9) If the Buyer refuses or fails to take delivery of Goods tendered in accordance with this Contract HITACHI shall be entitled to terminate this Contract with immediate effect, to dispose of the Goods as HITACHI may determine, and to recover from the Buyer any loss and expenses incurred as a result of such refusal or failure.
(10) Section 32 (2) of the Sale of Goods Act 1979 shall not apply. HITACHI shall not be required to give the Buyer the notice specified in Section 32 (3) of the Act.
(11) Unless expressly agreed in writing by HITACHI, all Goods shall be packed in accordance with HITACHI’s standard practice. The Buyer shall meet the costs of any special packaging requested by the Buyer or any packaging rendered necessary by delivery by any means other than HITACHI’s normal means of delivery.
(1) Notwithstanding delivery, property in the Goods supplied shall remain with HITACHI until those Goods and any other goods the subject of any other contract with HITACHI have been paid for in full (together with any accrued interest) and until property passes in accordance with this term:-
(a) Risk in the Goods shall pass on delivery and the Buyer shall store the Goods separately or in such a way as will show clearly that they are HITACHI’s property and the Buyer will ensure that they are kept in good condition and insured against loss or damage for HITACHI’s benefit. Until property in the Goods passes to the Buyer, the Buyer shall hold the proceeds of any claim on the insurance policy on trust for HITACHI and shall immediately account to HITACHI with the proceeds.
(b) The Buyer shall hold the Goods in a fiduciary capacity and as bailee for HITACHI who may without prejudice to any other of its rights repossess the Goods to which it has retained title as aforesaid and thereafter re-sell the same and for this purpose the Buyer hereby grants an irrevocable right and licence to HITACHI’s servants and agents to enter upon all or any of its premises with or without vehicles during normal business hours for the purpose of inspecting and/or repossessing Goods to which it has retained title. This right shall continue to subsist notwithstanding the termination of this Contract for any reason and is without prejudice to any accrued rights of HITACHI hereunder or otherwise.
(c) The Buyer may dispose of the Goods in the ordinary course of its business as principal and may pass title to a third party but the proceeds of sale arising therefrom shall be kept in a separate account on trust for HITACHI until such time as full payment for the Goods supplied has been made.
(d) HITACHI may at any time detach or separate any of its Goods which may have been incorporated in or attached to goods belonging to the Buyer or any third party.
(2) HITACHI reserve the right, exercisable at its option by notice in writing to the Buyer, to waive the provisions of subclause 5(1) above at any time before payment has been made for the Goods supplied by the Buyer and to declare that property in the Goods shall have passed to the Buyer.
(3) Notwithstanding that property in the Goods shall not have passed to the Buyer, HITACHI, without prejudice to any other of its rights, may sue for the price of the Goods supplied in the event that payment is not made on the due date.
(4) Any return of Goods wholly or partly by the Buyer to HITACHI, except in the case of defective Goods pursuant to Clause 8, shall be subject to HITACHI’s prior written consent and Buyer’s payment to HITACHI of interest charges for the period from the date of HITACHI’s shipment of
1. DEFINITIONS In these conditions;(1) “HITACHI” means: Hitachi Air Conditioning Europe SAS, UK Branch
(registration no. BR015653), Whitebrook Park, Lower Cookham Road, Maidenhead, Berkshire, SL6 8YA, United Kingdom.
(2) “Buyer” means: the person, firm or company specified overleaf, to whom HITACHI’s Quotation, Sales Confirmation or Invoice is addressed.
(3) “Goods” means: the goods to be sold by HITACHI to the Buyer under the Contract.
(4) “Contract” means: the contract of sale hereby formed between HITACHI and Buyer.
2. CONSTRUCTION OF CONTRACT(1) The terms of the Contract shall consist of the particulars overleaf and
these conditions. Any term overleaf which is at variance with these conditions shall prevail over these conditions, which shall be construed accordingly, except with regard to price in respect of which provisions of subclause 6 (2) shall prevail.
(2) No other terms (whether contained in any document issued by the Buyer or in any written or oral communication between the parties) shall apply to the Contract nor shall these conditions or the particulars overleaf be modified without HITACHI’s written agreement.
(3) These conditions and the particulars overleaf shall be a complete record of the agreement between the parties with regard to the sale of the Goods. These conditions apply to all sales of Goods by HITACHI to the Buyer and shall apply in place of and prevail over any terms or conditions contained or referred to in the Buyer’s order or in correspondence or elsewhere or implied by trade, custom, practice or course of dealing unless agreed to in writing pursuant to subclause 2 (2) above and any purported provisions to the contrary are hereby excluded or extinguished.
(4) The Buyer must ensure that any pre-contractual representation on which it wishes to rely has been specified in the particulars overleaf. In entering the Contract, the Buyer does not rely upon any such representation made by or on behalf of HITACHI which has not been so specified.
(5) The acceptance by HITACHI of any Buyer’s order, wholly or partly, does not imply any commitment by HITACHI to accept any other order (or any other part of an order) whenever placed.
3. QUOTATIONS AND ORDERS(1) Unless accepted before lapse or withdrawal, or renewed in writing by
HITACHI, quotations shall lapse automatically after 30 days, but may be withdrawn earlier by HITACHI.
(2) Quotations are for information only and are not firm offers. There shall be no binding contract until HITACHI has accepted the buyer’s order by despatching HITACHI’s official Sales Confirmation.
(1) The scope of supply by HITACHI under the Contract shall be strictly limited to those specified overleaf, and no other goods or services are included.
(2) HITACHI will use all reasonable endeavours to deliver the Goods on or before the delivery date specified overleaf, however, HITACHI does not undertake, guarantee or warrant that delivery will be made on the delivery date specified.
(3) Any such delivery date specified shall be extended by any period or periods during which the manufacture or delivery of the Goods or other work by HITACHI in connection with this Contract is prevented, hindered, delayed or rendered uneconomic by reason of a Force Majeure Event (as defined in clause 19 below).
(4) The Buyer acknowledges that, in the case of semiconductor products, optoelectronic products and other electronic components, due to the advanced technology in the Goods and the specialist nature of the manufacturing process, manufacture of the Goods by HITACHI’s normal means may result in a loss of yield. In the event of such a loss of yield HITACHI shall notify the Buyer and shall use its best endeavours to supply the Goods in accordance with this Contract. If due to a Force Majeure Event or due to loss of yield HITACHI has insufficient stocks to meet all its commitments HITACHI may apportion stock between its customers at its sole discretion.
(5) If any delivery time specified overleaf is so extended by more that 90 days then the Buyer shall be entitled to give written notice to HITACHI requiring the Goods to be delivered within 30 days of the date of such notice, failing which the Buyer shall have the right to give further written notice determining the Contract forthwith.
(6) HITACHI shall be entitled to deliver the Goods in one or more instalments. Where delivery is effected by instalment each instalment shall be treated as a separate contract. Delay in delivery or other default of any instalment shall not relieve the Buyer of its obligations to accept and pay for the remaining deliveries.
Hitachi Product Catalogue | 115
Conditions of Sale
from defective materials, faulty workmanship or otherwise howsoever arising and whether or not caused by the negligence of HITACHI, its employees or agents SAVE THAT HITACHI shall accept liability for death or personal injury caused by the negligence of HITACHI.
If the Buyer fails to pay HITACHI in accordance with these conditions or breaches any other of these conditions or any other contract with HITACHI or enters into a deed of arrangement or commits an act of bankruptcy or compounds with his creditors or if a receiving order is made against him or if (being a company) an order is made or a resolution is passed for the winding-up of the Buyer (otherwise than for the purposes of amalgamation or reconstruction previously approved in writing by HITACHI) or if a receiver is appointed over any of the Buyer’s assets or undertakings or if circumstances arise which entitle the Court or a creditor to appoint a receiver or manager or which entitle the Court to make a winding-up order or if the Buyer takes or suffers any similar or analogous action in consequence of debt HITACHI may, without prejudice to its other rights, postpone delivery or manufacture (both in respect of the Contract in question and any other contracts HITACHI might have with the Buyer) until such payment has been made or other breach rectified and/or (at its option) to terminate the Contract (and/or any other such contracts) and to recover payment for all deliveries already made and for the cost of materials and labour already expended for the purpose of future deliveries (less any allowance of the value thereof as utilised by HITACHI for other purposes) and also to recover from the Buyer a sum equivalent to HITACHI’s loss of profit arising out of such termination. The exercise of HITACHI’s option to postpone delivery or manufacture shall not prevent the subsequent exercise of HITACHI’s option to terminate the Contract and/or any other such contracts.
10. THIRD PARTY RIGHTS(1) In this clause 10 “Third Party Rights” shall mean any rights under letters
patent, registered or unregistered designs, trademarks, copyright or any other intellectual property rights and rights in know-how whether or not capable of being protected by statute, which are owned or controlled by any third party.
(2) Where any of the Goods are produced to the Buyer’s specification or where the Buyer’s use of the Goods infringes any Third Party Rights notwithstanding that the Goods themselves do not constitute such an infringement, the Buyer shall indemnify HITACHI against all actions, claims, costs, damages or losses arising from any infringement of such rights in respect of the Goods so produced or the use to which the Buyer has put the Goods as the case may be.
(3) Any reference by HITACHI to patents, copyright, registered designs, trade marks and analogous forms of protection shall not constitute a warranty of the validity thereof.
(4) HITACHI does not warrant that the Goods do not infringe any Third Party Rights, and all warranties to that effect whether express or implied, statutory or otherwise are hereby excluded. If at any time it is alleged that the Goods infringe any Third Party Rights, or if in HITACHI’s reasonable opinion such an allegation is likely to be made, HITACHI may at its option and at its own expense:
(a) modify or replace the Goods without detracting from the overall performance of the Goods, so as to avoid the infringement; or
(b) procure for the Buyer the right to continue to use the Goods; or (c) repurchase the Goods at the price paid by the Buyer.(5) HITACHI shall have no liability to the Buyer in the event of Goods infringing
or being alleged to infringe any Third Party Rights. In the event that the Goods are or may be the subject of Third Party Rights, HITACHI shall be obliged to transfer to the Buyer only such right, title or interest as HITACHI may have.
(6) The Buyer shall notify HITACHI forthwith of any claim made or action brought or threatened alleging infringement of any Third Party Rights. HITACHI shall have control over and conduct any such proceedings in such manner as it shall determine. The Buyer shall provide all such reasonable assistance in connection therewith as HITACHI may request.
(1) Unless expressly agreed in writing by HITACHI, all drawings, designs, specifications and particulars of dimensions and weights and other such information submitted by HITACHI are approximate only and HITACHI shall have no liability in respect of any deviation therefrom. HITACHI shall be entitled to amend the technical specifications of the Goods without notice.
(2) HITACHI accepts no responsibility for any errors, omissions or other defects in any drawings, designs or specifications prepared by, or on behalf of, the Buyer or the Buyer’s agents, sub-contractors or employees, and HITACHI shall be indemnified by the Buyer against any and all liabilities and expenses incurred by HITACHI arising therefrom.
such Goods to the Buyer to the date of HITACHI’s receipt of such Goods. Freight, insurance and any other expenses incurred in connection with such return shall be borne by the Buyer.
6. PRICES(1) Unless otherwise stated overleaf, prices of the Goods shall be exclusive of
VAT, export duty and foreign import duty and any other import or other taxes, which shall where applicable be the subject of additional charges.
(2) Prices stated in any quotation or in HITACHI’s Sales Confirmation are provisional only and subject to adjustment to take account of increases in HITACHI’s costs and overheads, including, without limitation, costs of carriage and labour costs. The Contract price shall be HITACHI’s price ruling at the date of despatch. All quotations/sales confirmations and invoices are issued subject to the unconditional reservation of HITACHI’s right to adjust prices in respect of the following:-
(a) Changes in the prevailing exchange rate between the currency in which the price is to be paid and the Japanese Yen.
(b) Changes in the current EU import duty.
(1) (1) If HITACHI has granted the Buyer credit facilities, the payment of the price must be made in full within 30 days of the date of invoice, unless otherwise specified overleaf or agreed to by HITACHI. Any extension of credit allowed for the Buyer may be changed or withdrawn at any time. Where no credit has been granted, payment must be made in full in cash prior to delivery. Payment shall be made in full direct to HITACHI in the currency invoiced. The Buyer shall not be entitled to exercise any right of set-off, counterclaim, abatement or analogous deduction against payment due to HITACHI. Time of payment is of the essence of a Contract. HITACHI reserves the right to suspend the provision of Goods to the Buyer where any amounts are overdue under any Contract with the Buyer until all such amounts have been paid.
(2) HITACHI shall be entitled to charge daily interest on any overdue sum at the rate of 3 per cent per annum above the current base lending rate of Barclays Bank PLC from due date until the date of actual payment in full (including any accrued interest) (after, as well as before, judgement).
(3) If, in the opinion of HITACHI, the creditworthiness of the Buyer shall have deteriorated prior to the delivery, HITACHI may require full or partial payment of the price prior to delivery or the provision of security for payment in full (including any accrued interest) by the Buyer in a form acceptable to HITACHI notwithstanding any credit terms that may have been agreed between HITACHI and the Buyer.
(4) Notwithstanding any purported contrary appropriation by the Buyer, all payments made by the Buyer to HITACHI shall be appropriated first to Goods which have been resold by the Buyer and then to Goods which remain in the possession or under the control of the Buyer.
(5) HITACHI is entitled to offset any amount owing to it from the Buyer against any amount owed to the Buyer by HITACHI.
8. DEFECTIVE GOODS(1) If the Goods are defective on delivery, and the defects arise from faulty
materials or workmanship and are not caused by fair wear and tear, abnormal or unsuitable conditions of storage, transportation or use, or the combination of the Goods with any goods not supplied by HITACHI or any act, neglect or default of the Buyer or any third party and HITACHI is given written notice of the defects promptly upon discovery by the Buyer and at any rate within six months (or such other period of time as may specifically be agreed to by HITACHI for certain types of Goods) after delivery then, unless otherwise specified overleaf, HITACHI’s sole obligation shall be (at its option) to repair or replace the defective item or allow the Buyer the price thereof and to pay or reimburse the reasonable carriage charges for the return of defective Goods to HITACHI and for delivery of the replaced or repaired item.
(2) Unless otherwise agreed between HITACHI and the Buyer, if any of the Goods are not HITACHI made, the provisions of subclause 8(1) above shall apply only to the extent covered by any warranty made by the supplier of such Goods to HITACHI.
(3) The Buyer shall retain the Goods at its premises until instructed by HITACHI to return them. Goods alleged to be defective shall be subject to inspection and testing by HITACHI at its own or (if HITACHI so chooses) at the Buyer’s premises and the Buyer shall allow HITACHI adequate facilities at the Buyer’s premises to investigate the complaint.
(4) Subject to subclause 8(1) above, HITACHI gives no representation or warranty and there is not incorporated in the Contract any condition whether express or implied, statutory or otherwise, as to the Goods other than the statutory warranty of title, and any such representations, conditions or warranties are hereby expressly excluded and HITACHI shall be under no liability to the Buyer for any loss, damage or injury (including special, direct, indirect or consequential loss and loss of profit) resulting
hitachiaircon.com Email: [email protected]: 01628 585 394
Conditions of Sale
16. WAIVER Failure by HITACHI to exercise or enforce any rights hereunder shall not
be deemed to be a waiver of any such right nor operate so as to bar the exercise or enforcement thereof at any time or times thereafter.
17. NOTICES Any notice hereunder shall be deemed to have been duly given if sent by
pre-paid first class post, telex, or telefax to the party concerned as its last known address. Notices sent by first class post shall be deemed to have been given seven days after despatch and notices sent by telex or telefax shall be deemed to have been given on the date of despatch.
The contract may be cancelled or rescheduled by the Buyer only with HITACHI’s written consent. In the event of such cancellation the Buyer shall pay to HITACHI a cancellation charge, equal to HITACHI’s cost incurred up to the date of cancellation plus HITACHI’s loss of profit. The amount of such charge shall be notified to the Buyer upon HITACHI’s written acknowledgement of cancellation and shall be paid within 30 days of such notification.
(1) If HITACHI is prevented, hindered or delayed from or in supplying the Goods in accordance with these conditions by a Force Majeure Event HITACHI may, at its option:
(a) suspend deliveries while the Force Majeure Event continues;(b) if HITACHI has insufficient stocks to meet its commitments, apportion
available stocks between its customers as it decides; or(c) terminate any contract so affected with immediate effect by written notice
to the Buyer; and HITACHI shall not be liable for any loss or damage suffered by the Buyer as a result.
(2) In this clause “Force Majeure Event” means an event beyond the reasonable control of HITACHI including, without limitation, strike, lock-out, labour dispute or shortage of labour, act of God, war, riot, civil commotion, malicious damage, compliance with a law or governmental order, rule, regulation or direction, accident, breakdown of plant or machinery, fire, flood, storm, earthquake, shortage of utilities, materials or other circumstances affecting the supply of materials from HITACHI’s normal source of supply for materials for the Goods.
The Buyer shall be responsible for all obligations, financial or otherwise, imposed in respect of the Goods, on either of the parties, under any environmental legislation applicable to the parties, including but not limited to Directive 2002/96/EC on waste electrical and electronic equipment and any legislation enacted pursuant to it.
The law of the Contract shall be English law and the parties hereby submit to the jurisdiction of the English Courts save that HITACHI shall be entitled to bring proceedings against the Buyer in the courts of any jurisdiction where the Buyer resides or carries on business.
The Buyer agrees that it shall not obtain any right, title or interest in or to any intellectual property (including, without limitation, patents, trademarks, registered or unregistered designs, copyrights and rights in designs or inventions) in the Goods and that it shall not do or permit anything to be done in its use of such intellectual property in the Goods which would or could jeopardise their validity.
(1) Headings herein are for easy reference purpose only, and shall not be construed as defining the scope or meaning of any provisions.
(2) The invalidity, illegality or unenforceability of the whole or part of a condition does not affect or impair the continuation in force of the remainder of these conditions.
(3) A person who is not a party to this contract has no right under the Contracts (Rights of Third Parties) Act 1999 to enforce any of its terms but this does not affect any right or remedy of a third party which exists or is available apart from that Act.
(4) A reference to a statutory provision includes a reference to the statutory provision as modified or re-enacted or both from time to time and any subordinate legislation made under the statutory provision.
April 2012
(3) All drawings, designs, specifications and information submitted by HITACHI are confidential and shall not be disclosed to any third party without HITACHI’s written consent.
(1) HITACHI shall not be liable for any indirect or consequential loss, loss of revenue, loss of goodwill, and/or loss of anticipated savings in each case howsoever caused.
(2) Without prejudice to subclause 12(1) HITACHI shall not be liable to the Buyer for any loss or damage whether for negligence, breach of contract, misrepresentation or otherwise, for a sum greater, in aggregate, than the amount actually paid by the Buyer to HITACHI under the Contract.
(3) The limitation of liability in subclauses 12(1) and 12(2) above shall not operate to exclude or restrict HITACHI’s liability for fraud or deceit or for death or personal injury caused by its negligence.
(4) For the avoidance of doubt HITACHI will have no liability to the Buyer for any delays in deliveries due to circumstances described in subclauses 4(3) and 4(4) of these conditions.
Neither party shall without the prior written consent of the other party (which shall not be unreasonably withheld) assign or sub-contract any of its rights or duties under the Contract and upon such consent being given shall furnish copies of any such assignments to the other party.
(1) If any license or consent of any government or other authority shall be required for the acquisition, carriage or use of the Goods by the Buyer, the Buyer shall obtain the same at its own expense and if necessary produce evidence of the same to HITACHI on demand. Failure to do so shall not entitle the Buyer to withhold or delay payment of the price. Any additional expenses or charges incurred by HITACHI resulting from such failure shall be for the Buyer’s account.
(2) If HITACHI needs to obtain an export license from the competent authorities of the U.K. or, in the case of a drop shipment, of another country, the Buyer shall furnish HITACHI with all information required by HITACHI for such purpose, including, but not limited to, the country of ultimate destination and the name and address of the consignee, and shall warrant that such information is true, accurate and sufficiently detailed. The Buyer further agrees to take all necessary procedures in connection therewith, including, but not limited to, application for and acquisition of international import certificate, import license and delivery verification, as applicable. The Buyer shall not directly or indirectly re-export the Goods, wholly or partly, or any relevant technology, services or technical data to those countries, the export of such Goods, technology, services or data to which is restricted under the laws of the government issuing the said relevant export license (except where such export license specifically approves). In the event that any of the Goods, or any materials, parts or components incorporated in them, or relevant technical data supplied by HITACHI are of United States origin, the Buyer agrees to comply with the U.S. Export Administration regulations.
(3) The Buyer shall not export, re-export or make available the Goods, wholly or partly or any relevant technical data to any destinations subject to United Nations, EC and/or national sanctions, or to any person or organisation subject to United Nations, EC and/or national sanctions, or for any purpose prohibited by such sanctions. The Buyer shall not resell the Goods, whether directly or indirectly, for export to a country in breach of any export controls, laws, rules or regulations of the country of origin of the Goods.
(4) The Buyer confirms that the Goods or any relevant technical data will not be used for purposes related to the proliferation of any weapons of mass destruction (chemical, biological or nuclear weapons and related missiles).
(5) The Buyer shall keep documentation for at least four (4) years from the date of HITACHI’s shipments as evidence that all Goods supplied to the Buyer have been received in the destination permitted under the laws of the government issuing the export licence, and the Buyer will produce such evidence upon HITACHI’s request.
(6) HITACHI’s obligations under any Contract shall be conditional upon all necessary licenses or consents being obtained from the relevant authorities.
(7) The Buyer shall separately confirm to HITACHI the strict observation hereof (Notice of Confirmation).
In any case where Goods are sold CIF or FOB or on the basis of other international trade terms, the meaning of such terms contained in Incoterms 2000 as revised from time to time shall apply except where inconsistent with any of the provisions contained in these conditions.
Specifications in this catalogue are subject to change without notice in order that HITACHI may bring the latest innovations to their customers, omitting typing errors.
Hitachi Air Conditioning Europe SAS.Whitebrook Park, Lower Cookham Road, Maidenhead, Berkshire SL6 8YA United Kingdom
tel: 01628 585 394
email: [email protected]
www.hitachiaircon.com
HELGB PC 001_12