ABC Fire Extinguisher at Work
Buckeye Fire Equipment
A Tradition of Innovation andReliability
In the fire protection industry for over 35 years, the Buckeye Fire Equipment Company is an innovative manufacturer of a complete line of Underwriters Laboratories (UL) Listed fire protection products: • Portable and wheeled fire extinguishers • Dry chemical extinguishing agents • Firefighting foam concentrates and foam
hardware • Engineered restaurant fire suppression
systems At our 165,000 square foot manufacturing facility located near Charlotte, North Carolina, Buckeye Fire Equipment produces high quality and reliable fire protection equipment for national and international markets. With sales and warehouse centers strategically located throughout the United States, as well as a global network of authorized distributors, Buckeye Fire Equipment is ready to provide its customers with timely and efficient sales, delivery, and service.
Fire Extinguishers Portable Hand and Wheeled
At the heart of the Buckeye Fire Equipment product lines are the hand-portable dry chemical fire extinguishers. The performance reliability of these extinguishers is a direct result of the stringent controls under which each component is produced.
Company and Product Profile
We mill and blend our own dry chemical agents (monoammonium phosphate based [ABC], potassium bicarbonate based [Purple K], and sodium bicarbonate based [Standard]) on site where each batch is tested and verified to meet our in-house and UL quality requirements. In our machining centers we produce our cylinders and valve component parts to exacting standards that are quality-assured by a manufacturing and inspection system certified to the latest revision of the ISO 9001 Quality Standard. On one of the most modern automated process lines in the world, the extinguishers are filled, pressurized, and leak tested to assure that only the highest quality extinguishers reach our customers.
Buckeye Fire Equipment also manufactures a wide selection of hazard specific fire extinguishers to meet your individual fire protection needs. These include clean gas extinguishers such as Carbon Dioxide and Halotron™, the Class K Wet Chemical extinguishers used for kitchen fire suppression, Class D extinguishers for use on metal fires, and the Water Mist extinguishers suitable for use on Class A fires where a Class C hazard may also exist.
BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 2
If your situation requires more fire-stoppingpower, Buckeye offers clean gas agents and allthree of our dry chemical agents in easily transportable wheeled units. Depending on theextinguishing agent you select, these wheeled units are available in capacities ranging from 50lbs. to 350 lbs. Please refer to the CatalogueProduct Tables for the models and sizes offered.
Buckeye Fire Equipment Research and Development Center
Firefighting Foams and Hardware
With one of the world’s largest capacity foam blending operations, Buckeye Fire Equipmentproduces a comprehensive line of firefightingfoam concentrates recognized through independent tests as among the best in theindustry.
Our wide array of foam concentrates assures that there is one designed to meet your firesuppression requirements.
As committed as we are to the quality andperformance of our foam concentrates, we are also committed to protecting the environment -our foam concentrates are manufactured withoutany EPA reportable components.
To complement the firefighting foam productline, Buckeye Fire Equipment manufacturesfoam storage, proportioning, and deliveryhardware that can be engineered for your specificneeds. This hardware may be used in both fixedor portable system installations. Our experttechnical staff can assist you in determining themost effective application for your potential hazard.
BBuucckkeeyyee KKiittcchheenn MMiisstteerr
UULL 330000 RReessttaauurraannttFFiirree SSuupppprreessssiioonn SSyysstteemm
Buckeye Fire Equipment is proud to introducethe next generation of UL-300 RestaurantCooking Area Fire Suppression Systems, theBuckeye Kitchen Mister Suppression System.
Although many restaurant systems brag aboutproduct innovation, improved technology, firefighting ability, and “ease of installation”, theBuckeye Kitchen Mister is the first product totruly deliver on that promise.
By combining the fire fighting ability of mistingtechnology, common sense features, and time saving patented innovations, the Kitchen Mistermakes all other systems seem complicated and outdated.
If reducing installation time by up to 50% isimportant to you, then your system has arrived.
Knocking Down the Fire with Buckeye Foam
Customer Driven to Serve You
Buckeye Fire Equipment is a customer drivencompany that prides itself on earning yourbusiness with every call. If you have questionsabout any of the products in this catalogue please do not hesitate to contact us.
BuckeyeCOMPLETE 5/24/07 4:53 PM Page 3
Portable ExtinguisherSelection Guide
The National Fire Protection Association (NFPA) has established the requirements for the number, size, placement, performance, and maintenance of portable fire extinguishers. These requirements are contained in NFPA 10, “Standard for Portable Fire Extinguishers”. Within this Standard it is stated that the selection of fire extinguishers for a given situation is determined by the character of the fires anticipated to be encountered, the construction and occupancy of the property to be protected, the ambient temperature of the area where the extinguisher will be located, and other factors that may dictate the selection of a particular type of extinguisher.
CLASSIFICATION Generally, fire extinguishers are selected based on the hazard(s) they are intended to protect. Classifications have been established to categorize what type of extinguishing agent is best suited for the fire hazard. These classifications are A, B, C, D, and K. A fire extinguisher assigned a Class A classification is suitable for use on ordinary combustibles; wood, paper, cloth, rubber, and many of the plastics. The B classification is intended for use on flammable liquids, combustible liquids, petroleum greases, oils, oil-based paints, solvents, alcohols, and flammable gases. Class C extinguishers are for use on fires involving energized electrical equipment. For fires involving combustible metals (magnesium, lithium, zirconium, etc.), Class D extinguishers are best to use. An extinguisher designated Class K best protects cooking appliances that utilizecooking media such as vegetable oils and animal fats. RATING Along with the classification, the numerical rating of an extinguisher is an important factor in the proper selection of anextinguisher. The rating is a measure of the
extinguishing potential of the fire extinguisher and is developed on the basis of comparative fire tests (Reference UL 711, Standard for Rating and Testing of Fire Extinguishers). Only the Class A and Class B classifications carry numerical ratings. Basically, the higher the number associated with the classification letter, the larger the fire the extinguisher has the potential to put out. Please refer to NFPA 10 when determining the rating necessary for the floor area requiring protection. There are no numerical ratings associated with Class C, D, or K classifications. Comparative fire tests are not conducted. In the case of Class C, the electrical nonconducting characteristics of the agent are verified, not the extinguishing potential. For Class D, only the amount of agent and application method needed to control a metal fire of a certain size and type is tested. And for Class K, the fire extinguishing characteristics of the extinguisher have only been determined for a single size fire source. In the typical rating of an extinguisher, for example 3A-40B:C, the 3 and the 40 indicate the extinguishing potential of the unit for a Class A and Class B fire respectively. The C indicates that the extinguishing agent will not conduct electricity, preventing shock to the user if used on energized electrical equipment. On the following page is a reference chart with the basic rating parameters for extinguishers. SUMMARY To provide the best protection of life and property from the destructive force of fire, it is critical that the proper fire extinguisher selection be made. The Classification and Rating of an extinguisher are vital pieces of information for making that selection. Using NFPA 10 for guidance, matching the right fire extinguisher to the potential hazard, providing a sufficient number of extinguishers for the area to be protected, locating the extinguishers for maximum visibility and accessibility, and personnel trained in the use and maintenance of the extinguisher will significantly lessen the risk of loss.
BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 4
EXTINGUISHER PLACEMENTAND RATING REFERENCE CHARTS
Placement/Accessibility Of Extinguisher
CLASS AFIRE HAZARD
CLASS BFIRE HAZARD
CLASS CFIRE HAZARD
CLASS DFIRE HAZARD
CLASS KFIRE HAZARD
MAXIMUMTRAVEL
DISTANCE
75 FeetMaximum area that oneextinguisher can protect
and meet the 75’ rule= 11,250 sq. ft.
50 FeetMaximum area that oneextinguisher can protect
and meet the 50’ rule= 5000 sq. ft.
In accordance withthe Class A or B
hazard it is protecting75 Feet
30 FeetMaximum area that oneextinguisher can protect
and meet the 30’ rule= 1800 sq. ft.
Basic Extinguisher Rating ParametersORDINARY COMBUSTIBLES
Class A Fires(Wood, Paper, Cloth, Rubber)
FLAMMABLE LIQUIDS
Class B Fires(Gasoline, Oil, Paints, Solvents, Propane)
ENERGIZEDELECTRICAL
Class C Fires(Computers,
Electrical Panels,Transformers)
COOKINGMEDIA
Class K Fires(Cooking
Appliances)
NumericalRating
WoodPanel
Fire Test
Wood Crib Fire Test
Overall Dims. No. of Trade Size of (inches) Members Members (inches)
NumericalRating
MinimumDischargeRequired
Fire TestPan Size(expert)
EstimatedNovice
Capability
1A 8’x 8’ 20 x 20 x 18 72 2 x 2 x 20 2B 8 Sec 5 sq ft 5 sq ft2A 10’x 10’ 25 x 25 x 24 112 2 x 2 x 25 5B 8* Sec 12.5 sq ft 10 sq ft 3A 12’x 12’ 29 x 29 x 27 144 2 x 2 x 29 10B 8* Sec 25 sq ft 20 sq ft 4A 14’x 14’ 32 x 32 x 30 180 2 x 2 x 32 20B 8* sec 50 sq ft 40 sq ft 6A 17’x 17’ 36 x 36 x 34.5 230 2 x 2 x 36 40B 13 Sec 100 sq ft 60 sq ft 10A N/A 43 x 43 x 40.5 324 2 x 2 x 43 60B 17 Sec 150 sq ft 80 sq ft20A N/A 55 x 55 x 57.5 256 2 x 4 x 55 80B 20 Sec 200 sq ft 80 sq ft 30A N/A 64 x 64 x 64.5 324 2 x 4 x 64 120B 26 Sec 300 sq ft 120 sq ft40A N/A 69 x 69 x 71.5 400 2 x 4 x 69 160B 31 Sec 400 sq ft 160 sq ft
NO FIRE TEST
Extinguishing agent istested for electricalnonconductivity. Ifnonconductive, the “C”symbol is added to the existing classification.
No numerical ratingis given for Class C
Fire Test Fryer Size
18”x24”x18”Deep Fat Fryer
No numerical ratingis given for Class K
Discharge TimeApprox. 60 Seconds
*13 Seconds with an “A” rating
There are three general classifications of hazard areas- low, ordinary, and extra.Minimum rating required for low or ordinary hazard areas is 2A.Minimum rating for extra hazard areas is 4A.
Maximum floor area that can be protected per unit of A is 3,000 sq. ft. for low hazard.Maximum floor area that can be protected per unit of A is 1,500 sq. ft. for ordinary hazard.Maximum floor area that can be protected per unit of A is 1,000 sq. ft. for extra hazard.
To determine the rating necessary for proper protection, divide the total sq. ft. by the unit of A for the hazard.
Example: An extinguisher is needed to protect an office area (low hazard) that measures 10,500 sq. ft.Total sq. ft. = 10,500. Unit of A for low hazard is 3,000. The rating necessary to protect the area is10,500 ÷ 3,000 = 3.5 units of A. Rounding up to the next numerical rating would mean that a 4A-ratedextinguisher would be needed to protect the office.
If the area were classified as “extra hazard” then the extinguisher would need to be rated 20A(10,500 ÷ 1,000 = 10.5 units of A. Rounded up to the next numerical rating = 20A).
BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 5
FEATURES:• Monoammonium Phosphate based dry chemical agent.• Rated for use on “A”, “B”, and “C” class fires. Provides the widest, most practical range of fire protection.• Rechargeable• Steel cylinders with a baked-on polyester enamel coating stand up to harsh environments.• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards• Optional brass valves on some units. 30 lb. unit has brass valve only
TYPICAL USES: Offices, warehouses, woodworking areas, farms, general public assembly areas, and homes. The ABC extinguisheris not recommended for use on sensitive electronic equipment or aircraft structure.
Model 2.5 ABCV/B
5 ABC 5 ABCV/B
10 TALLABC
10S ABC 20S ABC 30S ABC
Part #Alum. Valve 13315 10914 25614 11340 11310 12120 N/A
Part #Brass Valve N/A 10915 25615 11341 N/A 12121 12905
AgentCapacity
2.5 lb.(1.13 kg)
5 lb.(2.27 kg)
10 lb.(4.54 kg)
20 lb.(9.07 kg)
30 lb.(13.6 kg)
UL Rating 1A-10B:C 3A-40B:C 4A-80B:C 4A-60B:C 20A-120B:C 20A-160B:CDischarge Time 9 sec 14 sec 22 sec 18 sec 26 sec 32 secRange (ft/m) 9-15 / 2.7-4.6 12-18 / 3.7-5.5 15-21 / 4.6-6.4 25-30 / 7.6-9.1OperatingPressure
100 psi(689 kPa)
195 psi(1344 kPa)
Bracket Vehicle Wall Vehicle WallUSCG Approval Type B:C Size I Type A Size II
Type B:C Size IType A Size II
Type B:C Size IIType A Size II
Type B:C Size IIIType A Size II
Type B:C Size IVShip Wt. 5.5 lbs.
(2.5 kg)10 lbs.
(4.5 kg)10.25 lbs(4.7 kg)
18.25 lbs.(8.3 kg)
18.75 lbs.(8.6 kg)
33.5 lbs.(15.2 kg)
52.25 lbs.(23.7 kg)
Height 14.75 in(37.5 cm)
16.375 in(41.6 cm)
21 in(53.3 cm)
16.75 in(42.5 cm)
21.25 in(53.8 cm)
27.375 in(69.4 cm)
Width 4.875 in(12.4 cm)
7.25 in(18.4 cm)
7.75 in(19.7 cm)
8.25 in(21 cm)
8.75 in(22.2 cm)
Diameter 3.375 in(8.6 cm)
4.25 in(10.8 cm)
5.125 in(13 cm)
6 in(15.2 cm)
7.5 in(19.1 cm)
ABC DRY CHEMICALHAND HELD
STORED PRESSURE FIRE EXTINGUISHERS
BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 6
STANDARD DRY CHEMICALHAND HELD
STORED PRESSURE FIRE EXTINGUISHERS
FEATURES:• Sodium Bicarbonate based dry chemical agent.• Rated for use on “B” and “C” Class fires.• Rechargeable• Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments.• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards.
TYPICAL USES: Kitchens, garages, boats, vehicles, and extinguisher use training.The Standard extinguisher is not recommended for use on sensitive electronic equipment.
Model 2.5 STD V/B 5.5 STD 5.5 STD V/B 10 STD 20S STDPart # Aluminum Valve 13415 11014 13514 11840 12220
AgentCapacity
2.5 lbs.(1.13 kg)
5.5 lbs.(2.50 kg)
10 lbs.(4.54 kg)
20 lbs.(9.07 kg)
UL Rating 10 B:C 40 B:C 120 B:CDischarge Time 9 seconds 14 seconds 26 seconds
Range 9-15 ft(2.7-4.6 m)
12-18 ft(3.7-5.5 m)
15-21 ft(4.6-6.4 m)
OperatingPressure
100 psi(689 kPa)
195 psi(1344 kPa)
Bracket Vehicle Wall Vehicle WallUSCG Approval Type B:C Size I Type B:C Size II Type B:C Size III
Ship Wt. 5.5 lbs.(2.5 kg)
10.5 lbs.(4.8 kg)
10.75 lbs.(4.9 kg)
18.25 lbs.(8.3 kg)
33.5 lbs.(15.2 kg)
Height 14.75 in(37.5 cm)
16.375 in(41.6 cm)
21 in(53.3 cm)
21.25 in(53.8 cm)
Width 4.875 in(12.4 cm)
7.25 in(18.4 cm)
7.75 in(19.7 cm)
8.75 in(22.2 cm)
Diameter 3.375 in(8.6 cm)
4.25 in(10.8 cm)
5.125 in(13 cm)
7.5 in(19.1 cm)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 7
PURPLE K DRY CHEMICALHAND HELD
STORED PRESSURE FIRE EXTINGUISHERS
FEATURES:• Potassium Bicarbonate based dry chemical agent.• Rated for use on “B”, and “C” class fires. Most effective dry chemical agent for Class B fires• Rechargeable• Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments.• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards• Optional brass valves on some units. 30 lb. unit has brass valve exclusively.
TYPICAL USES: Garages, service bays, boats, vehicles, fuel storage and transfer areas.The Purple K extinguisher is not recommended for use on sensitive electronic equipment.
Model 2.5 PK V/B 5 PK 5 PK V/B 10 PK 20S PK 30S PKPart #
Alum. Valve13515 11214 25914 11740 12620 N/A
Part #Brass Valve
N/A N/A N/A N/A 12621 12805
AgentCapacity
2.5 lbs(1.13 kg)
5 lbs.(2.27 kg)
10 lbs(4.54 kg)
20 lbs.(9.07 kg)
30 lbs.(13.6 kg)
UL Rating 10 B:C 20 B:C 80 B:C 120 B:C 160 B:CDischarge
Time9 seconds 22 seconds 26 seconds 32 seconds
Range 9-15 ft(2.7-4.6 m)
12-18 ft(3.7-5.5 m)
15-21 ft(4.6-6.4 m)
25-30 ft(7.6-9.1 m)
OperatingPressure
100 psi(689 kPa)
195 psi(1344 kPa)
Bracket Vehicle Wall Vehicle WallUSCG
ApprovalType B:C Size I Type B:C Size II Type B:C Size III Type B:C Size IV
Ship Wt. 5.5 lbs(2.49 kg)
10 lbs.(4.5 kg)
10.25 lbs.(4.6 kg)
18.25 lbs.(8.3 kg)
33.5 lbs.(15.2 kg)
52.25 lbs.(23.7 kg)
Height 14.75 in(37.5 cm)
16.375 in(41.6 cm)
21 in(53.3 cm)
21.25 in(53.8 cm)
27.375 lbs.(69.4 cm)
Width 4.875 in(12.4 cm)
7.25 in(18.4 cm)
7.75 in(19.7 cm)
8.75 in(22.2 cm)
Diameter 3.375 in(8.6 cm)
4.25 in(10.8 cm)
5.125 in(13 cm)
7.5 in(19.1 cm)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 8
HALOTRON™HAND HELD AND WHEELED
STORED PRESSURE FIRE EXTINGUISHERS
FEATURES:• Residue-free Hydrochlorofluorocarbon gas agent pressurized with argon.• Excellent replacement for Halon 1211 extinguishers.• Rechargeable steel cylinders with baked-on polyester enamel coating that stands up to harsh environments.
Wheeled units have DOT approved 4BW240 cylinders, rugged frames, and semi-pneumatic tires.• All units are manufactured to ANSI/UL 2129 and ANSI/UL 711 Standards.• Optional chrome-plated brass valves on some units (standard on Wheeled Extinguishers).
TYPICAL USES: Computer rooms, telephone switch rooms, data storage areas, boats, and flight lines.
Model 2.5F 2.5FV/B
2.5H 2.5HV/B
5F 5F V/B 5H 5H V/B 11 15
Part #Alum. Valve
70258 70251 70259 70256 70510 70550 75550 75555 71100 71550
Part #Brass Valve
NotAvailable
70511 70551 75551 75556 71101 71551
Agent Capacity 2.5 lbs(1.13 kg)
5 lbs.(2.27 kg)
5.5 lbs.(2.49 kg)
11 lbs.(5 kg)
15.5 lbs.(7.03 kg)
UL Rating 2B:C 5B:C 1A-10B:C 2A-10B:CDischarge Time 9 seconds 13 seconds
Range 6-10 ft(1.8-3 m)
9-15 ft(2.7-4.5 m)
12-18 ft(3.7-5.5 m)
OperatingPressure
100 psi(689 kPa)
125 psi(862 kPa)
Bracket Wall Vehicle Wall Vehicle Wall Vehicle Wall Vehicle WallUSCG
ApprovalNot Applicable Type B:C
Size IType B:C
Size IIShip Wt. 5.25 lbs
(2.4 kg)5.5 lbs.
(2.49 kg)5.75 lbs(2.6 kg)
9.25 lbs.(4.2 kg)
9.5 lbs.(4.3kg)
10 lbs.(4.5 kg)
10.25 lbs.(4.7 kg)
21.25 lbs.(9.6 kg)
25.75 lbs.(11.7 kg)
Height 13.375 in (34 cm) 16.375 in (41.6 cm) 17.5 in (44.5 cm)Width 5.625 in
(14.3 cm)6.75 in
(17.1 cm)6.5 in
(16.5 cm)7.25 in
(18.4 cm)6.5 in
(16.5 cm)7.25 in
(18.4 cm)8.625 in
(21.9 cm)Diameter 3.375 in (8.6 cm) 4.25 in (10.8 cm) 7 in (17.8 cm)
Wheeled ExtinguishersModel Part # Capacity UL
RatingDischarge
TimeRange Unit
Height x Width x DepthHose
Diameter x LengthShip
WeightW-65 76500 65 lbs
(29.5 kg)4A-40B:C 17
seconds15-25 ft
(4.6-7.6 m)50 x 24 x 41.5 in
(127 x 61 x 105 cm).75 in x 25 ft
(1.9 cm x 7.6 m)300 lbs
(136 kg)W-150 71500 150 lbs
(68 kg)10A-80B:C 23
seconds23-36 ft
(7-10.7 m)62 x 24 x 41.5 in
(157.5 x61 x 105 cm)1 in x 40 ft
(2.5 cm x 12.2 m)480 lbs
(218 kg)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 9
CARBON DIOXIDEHAND-HELD AND WHEELED
FIRE EXTINGUISHERS
FEATURES:• Residue-free carbon dioxide gas extinguishing agent.• Hand-held units use aluminum cylinders with a baked-on polyester enamel coating to withstand harsh
environments.• Wheeled units are constructed with spun steel cylinders, rugged frames, and pneumatic tires and are
designed to be easily operated by one person.• All units manufactured to ANSI/UL 154 and ANSI/UL 711 Standards and use DOT compliant cylinders.• Plated brass valves on both hand-held and wheeled units.• Optional tow loops offered on the wheeled extinguishers.
TYPICAL USES: Refineries, shipboard, laboratories, construction sites, chemical plants, and manufacturingfacilities.
Hand-Held ExtinguishersModel 5CD 10CD 15CD 20CD
Part Number 45100 45600 46100 46600Agent Capacity 5 lbs. (2.27 kg) 10 lbs. (4.54 kg) 15 lbs. (6.80 kg) 20 lbs. (9.07 kg)
UL Rating 5B:C 10B:CDischarge Time 8 seconds 10 seconds 15 seconds 20 seconds
Range 4-8 ft (1.2-2.4 m)Bracket Wall
USCG Approval Type B:C Size I Type B:C Size IIShip Wt. 13.75 lbs. (6.3 kg) 27.75 lbs. (12.6 kg) 37.75 lbs. (17.1 kg) 49.0 lbs. (22.2 kg)Height 17.375 in (44.1 cm) 19.75 in (50.2 cm) 26.375 in. (67 cm) 26.875 in (68.2 cm)Width 8.25 in (21 cm) 12 in (30.5 cm) 13 in (33 cm)
Diameter 5.25 in (13.3 cm) 6.89 in (17.5 cm) 8 in (20.3 cm)
Wheeled ExtinguishersModel Part # Capacity UL
RatingDischarge
TimeRange Unit
Height x Width x DepthHose
Dia x LengthShip
WeightC-50-SE 35050 50 lbs.
(22.68 kg)40
seconds60 x 30 x 21 in
(152.4 x 76.2 x 53.3 cm)1 in x 15 ft
(2.5 cm x 4.56 m)250 lbs.
(113.4 kg)C-100-SE 35100 100 lbs.
(45.36 kg)
20B:C80
seconds
15 ft(4.6m) 65 x 30 x 21 in
(165.1 x 76.2 x 53.3 cm)1 in x 40 ft
(2.5 cm x 12.2 m)390 lbs.
(176.9 kg)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 10
AUTOMATIC SPOTPROTECTION
FEATURES:• Designed to provide supplemental protection suitable for some local and total flood applications.• Two mount styles available, charged with multipurpose dry chemical (ABC) or clean agent Halotron™.• The cylinders are constructed and tested to the same engineering standards as our portable extinguishers.• These units are not Underwriters Laboratories Listed and are not intended for use in lieu of an engineered
system. They are not to be multiple mounted.
VERTICAL MOUNT STYLE
Agent Multipurpose ABC Dry Chemical Halotron™Part No. 80250 80501 81001 82001 87100 87200
Capacity (lb./kg) 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 18 lbs/ 8.2 kg 25 lbs/ 11.3 kgShip Wt. (lb./kg) 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg
Operating Pressure 100 psi (689 kPa) 195 psi (1344 kPa) 100 psi (689 kPa)Length 15.25 in 17.25 in 17.625 in 21.875 in 17.875 in 21.875 in
Diameter 3.375 in 4.25 in 6.0 in 7.5 in 7.0 in 7.5 inMax Total Flood-
Volume 120 cu ft 180 cu ft 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft
Max Total Flood-Height above Hazard 7.5 ft 13 ft 14 ft 8 ft 10 ft
Local ApplicationCoverage Areas 4 ft x 4 ft 4 ft x 6 ft 10 ft x 10 ft 12 ft x 13 ft 4 ft x 4 ft 6 ft x 6 ft
Max Local Application- Height Above Hazard = 4 feet for all models
HORIZONTAL MOUNT STYLE
Agent Multipurpose ABC dry chemical Halotron™Part No. 80251 80521 81021 82021 87105 87205
Capacity (lb./kg) 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 18 lbs/ 8.2 kg 25 lbs/11.3 kgShip Wt. (lb./kg) 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg
Operating Pressure 100 psi (689 kPa) 195 psi (1344 kPa) 100 psi (689 kPa)Length 14.25 in 17.25 in 20.875 in 21.875 in 17.875 in 21.875 in
Diameter 3.375 in 4.25 in 5.125 in 7.5 in 7.0 in 7.5 inMax Total Flood-
Volume 120 cu ft 180 cu ft 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft
Max Total Flood-Height above Hazard 7.5 ft 13 ft 14 ft 8 ft 10 ft
Local ApplicationCoverage Areas 4 ft x 4 ft 4 ft x 6 ft 10 ft x 10 ft 12 ft x 13 ft 4 ft x 4 ft 6 ft x 6 ft
Mounting Bracket 700287 700270 700226 700229 700228 700229
Max Local Application- Height Above Hazard = 4 feet for all models
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 11
DRY CHEMICALWHEELED FIRE EXTINGUISHERS
FEATURES:
• Three choices in dry chemical agents are available to suit your particular fire protection needs:Monoammonium Phosphate (ABC), Sodium Bicarbonate (Standard), and Potassium Bicarbonate (Purple K).
• The ABC extinguisher is rated for use on “A”, “B”, and “C” class fires, providing the widest, most practicalrange of fire protection. The Standard and Purple K extinguishers are rated for use on B:C classes of fires.
• Designed for one-man operation. Easily transported through doorways and over rough terrain.• All models are also available as stationary units.• Every model is rechargeable.• Rugged steel cylinders and frames with baked-on polyester enamel coatings stand up to harsh environments.• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards.• Plated brass cylinder valves and hose valve assemblies.• All pressurized cylinders are DOT approved. Extinguishers part numbered 30010, 30110, 30030, 30310, &
31210 are USCG approved.
TYPICAL USES: Offshore rigs, ship docks, refineries, chemical plants, aircraft ramps, remote construction sites, largelaboratories, processing plants, storage and loading areas.These extinguishers are not recommended for use on sensitive electronic equipment.
WHEELED EXTINGUISHER PHYSICAL ATTRIBUTESMODEL PART
NO.SHIP
WEIGHTHEIGHT WIDTH DEPTH HOSE
LENGTH x DIAWHEEL
DIAMETERA-50-SP 30010
K-50-SP 30030
193 lbs.(88 kg)
47 inches(119 cm)
24 inches(61 cm)
26.5 inches(67 cm)
25 ft. x .50 in(7.6 m x 1.3 cm)
12.3 x 3.5 in(31.3 x 8.9 cm)
A-150-SP 30110K-150-SP 30310
343 lbs.(156 kg)
51 inches(128 cm)
26 inches(66 cm)
38 inches(96.5 cm)
A-150-RG 31120K-150-RG 31320
413 lbs.(188 kg)
S-150-RG 31220 438 lbs.(199 kg)
50 inches(127 cm)
24 inches(61 cm)
42 inches(105 cm)
16 x 4 in(40.6 x 10.2 cm)
31140*A-150-RG31150**31340*K-150-RG
31350**
448 lbs.(204 kg)
31240*S-150-RG31250**
473 lbs.(215 kg)
55 inches(139 cm)
32 inches(81.3 cm)
46 inches(117 cm)
36 x 2.5 in(91.4 x 6.4 cm)
* Steel Wheels
** Steel wheels withrubber tread
A-150-PT 31110
K-150-PT 31310345 lbs.(157 kg)
S-150-PT 31210 370 lbs.(168 kg)
50 inches(127 cm)
24 inches(61 cm)
42 inches(105 cm)
50 ft x .75 in(15.2 m x 1.9 cm)
16 x 4 in(40.6 x 10.2 cm)
32120*A-350-RG 32140**
32320*K-350-RG 32340**
810 lbs.(368 kg)
32220*S-350-RG 32240**
860 lbs.(391 kg)
32110*A-350-PT
32130**
32310*K-350-PT 32330**
700 lbs.(318 kg)
32210*S-350-PT32230**
750 lbs.(341 kg)
58 inches(147 cm)
36 inches(91.4 cm)
48 inches(122 cm)
50 ft x 1 in(15.2 m x 2.5 cm)
36 x 2.5 in(91.4 x 6.4 cm)
* Steel Wheels
** Steel wheels withrubber tread
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 12
ABCWHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONSMODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE
TIMEDISCHARGE
RANGE
A-50-SP 30010 50 lbs.(22.7 kg)
30A-160B:C 35 seconds 25-35 ft(7.6-10.7 m)
A-150-SP 30110 47 seconds3112031140A-150-RG31150
43 seconds
A-150-PT 31110
125 lbs.(56.7 kg)
40A-240B:C
45 seconds32120
A-350-RG 32140 53 seconds
32110A-350-PT 32130
300 lbs.(136 kg)
40A-320B:C
57 seconds
30-40 ft(9.1-12.2 m)
PURPLE KWHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONSMODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE
TIMEDISCHARGE
RANGE
K-50-SP 30030 50 lbs.(22.7 kg)
160 B:C 34 seconds25-35 ft
(7.6-10.7 m)K-150-SP 30310 54 seconds
3132031340K-150-RG31350
57 seconds
K-150-PT 31310
125 lbs.(56.7 kg)
54 seconds32320
K-350-RG 32340 56 seconds
32310K-350-PT
32330
300 lbs.(136 kg)
320B:C
58 seconds
30-40 ft(9.1-12.2 m)
STANDARDWHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONSMODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE
TIMEDISCHARGE
RANGE3122031240S-150-RG31250
48 seconds
S-150-PT 31210
150 lbs.(68 kg)
240B:C
43 seconds32220
S-350-RG 32240 59 seconds
32210S-350-PT
32230
350 lbs.(159 kg) 320B:C
50 seconds
30-40 ft(9.1-12.2 m)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 13
SPECIALTYFIRE EXTINGUISHERS
WET CHEMICAL – CLASS K• Contains a blend of Potassium Acetate and Potassium Citrate that is extremely effective
in suppressing high temperature fires fueled by the unsaturated cooking oils used intoday’s restaurant appliances. The agent is applied by a misting discharge nozzle thatprevents the splashing and spreading of the oils. This extinguisher is designed tocomplement existing pre-engineered hood systems. Also carries an “A” Rating.
• Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.
Model WC-6 LiterPart # 50006
Agent Capacity 6 Liter (1.59 gallons)UL Rating 1-A:K (Tested to extinguish one 18” X 24” fryer)
Discharge Time 54 secondsOperating Pressure 100 psi (689 kPa)
Bracket WallShip Wt. 22 lbs. (10 kg)Height 19.25 inches (48.9 cm)
Width (including hose) 9 inches (22.9 cm)Cylinder Diameter 7 inches (17.8 cm)
Construction Stainless steel cylinder with plated brass valve
WATER• Uses water as the extinguishing agent. This economical and environmentally friendly
extinguisher is ideal for schools, theaters, retail storerooms, and anywhere Class Ahazards exist.
• Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.
Model 500Part # 50000
Agent Capacity 2.5 gallon (9.6 liters)UL Rating 2A
Discharge Time 50 secondsOperating Pressure 100 psi (689 kPa)
Bracket WallShip Wt. (empty) 7.75 lbs. (3.5 kg)
Height 24.5 inches (62.2 cm)Width (including hose) 9 inches (22.9 cm)
Cylinder Diameter 7 inches (17.8 cm)Construction Stainless steel cylinder with plated brass valve
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 14
SPECIALTYFIRE EXTINGUISHERS
WATER MIST• Uses deionized water as the extinguishing agent. The unique misting nozzle creates a fine
water spray that improves the cooling and soaking characteristics of the agent and limitsthe scattering of burning material. This extinguisher is the right choice for Class A fireswhere there is a potential for Class C (electrical) safety hazards. Ideal for hospitals, cleanrooms, and telecom facilities. The non-magnetic properties of the extinguisher make itperfect for use in proximity to MRI equipment.
• Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.
Model WM250Part # 51000
Agent Capacity 2.5 gallon (9.6 liters)UL Rating 2A:C
Discharge Time 73 secondsOperating Pressure 100 psi (689 kPa)
Bracket WallShip Wt. 29.5 lbs. (13.4 kg)Height 28 inches (71.1 cm)
Width (including hose) 14 in (35.6 cm)Cylinder Diameter 7 inches (17.8 cm)
Construction Stainless steel cylinder with plated brass valve
COMBUSTIBLE METALS – CLASS D• Specially designed for use on combustible metals fires, this extinguisher features a
discharge assembly that keeps the operator at a safe distance while providing accurateapplication of the agent on the fire. From the heat of the fire, the sodium chloride basedagent forms a crust to exclude air from the burning material.
• Manufactured to Factory Mutual standards.
Model 30DPart # 52100
Agent Capacity 30 lbs. (13.6 kg)FM Rating D
Discharge Time 28 secondsOperating Pressure 195 psi (1344 kPa)
Bracket WallShip Wt. 55 lbs. ( 24.95 kg)
Height (with hose) 33 inches (83.8 cm)Width (with hose) 16 inches (40.6 cm)Cylinder Diameter 8 inches (20.3 cm)
Construction Steel Cylinder
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 15
Protect Your Business With The Best!
Protecting the modern commercial kitchen from the ever present danger of fire is the reason Buckeye Fire Equipment designed the Kitchen Mister Fire System. Utilizing state of the art misting technology, the Kitchen Mister System extinguishes potentially deadly kitchen fires quicker and more effectively than any other kitchen system ever developed, period. The modern commercial kitchen, with its open flames, hot surfaces, and grease laden environment combine all the elements necessary for a fire. Extinguishing fires quickly, before they can spread, is the best way to limit fire damage and get your operation back in business.
Don’t Take Chances, Demand The Best!
Simple is Better
The constant changes and complicated requirements of most restaurant cooking systems have made design and installation errors a concern for Fire Equipment Distributors everywhere. Obviously, a simple system design reduces the possibility of design and installation errors. At Buckeye we’ve listened to these concerns and understand that simple is better. One look at the Kitchen Mister and you can see what a difference common sense makes:
System Cylinders
The Models BFR-5, BFR-10, BFR-15, and BFR-20 cylinders are designated by flow point capacity (so the BFR-5 supports five (5) flow points and so on) instead of the amount of agent they hold. Recharge is available in 5 and 10 flow point containers so there’s never a chance of error.
BBuucckkeeyyee KKititcchheenn MMiisstteerrUULL 330000 RReessttaauurraanntt FFiirree SSuupppprreessssiioonn SSyysstteemm
Discharge Nozzles All five (5) Kitchen Mister nozzles come equipped with a color identification band, red, blue, green, white, and yellow. This allows for easy identification of the nozzle even when it’s installed in difficult locations such as a duct or plenum area. The nozzle is also stamped with its Model Number.
System Releasing Module
The System Releasing Module has been designed with a viewing window to assure that the actuation cartridge has been properly installed and to see the date written on the cartridge. It also includes high quality
ratchets that allow the gas valve to be opened and tested from the SRM. The unit can be mounted directly on a cylinder or can be mounted remotely. It can actuate up to five (5) agent cylinders and does not require a bracket for wall mounting.
Buckeye Shielded Cable The Kitchen Mister Shielded Cable Interface is used to connect Buckeye Shielded Cable to any standard 1/2” conduit connection device. The use of Buckeye Shielded Cable (Patent Pending) instead of conduit and corner pulleys for connecting the gas valve, remote pull station, and fusible link line to the Systems Releasing Module reduces installation time by up to 50%.
Advanced Automatic Detection The Buckeye Kitchen Mister System uses reliable Globe ML style fusible links for automatic detection. However, with the Kitchen Mister System no conduit and only one bracket is required in the entire plenum area. Just bring the cable into the plenum through an approved hood penetration, install a terminal bracket on the far end of the hood, and attach the cable. The links are attached directly to the cable without using conduit or brackets, making them quick to install and easy to move. Fusible Link Holders are also available if a continuous fusible link line is desired.
BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 16
FOAM CONCENTRATESAND
EQUIPMENT
FEATURES and SERVICES:• The widest selection of earth-friendly fire fighting foam concentrates in the industry.• Independent tests have shown Buckeye foam concentrates to be superior in quality and performance.• Wide array of foam producing hardware and components designed to maximize foam effectiveness.• Staff of experienced sales technicians to help you choose the right foam, application equipment, and design
for your foam system.• Buckeye Fire Equipment can provide assistance for system testing/maintenance and emergency repair
service.• In-house laboratory staffed with knowledgeable quality specialists to perform analysis of both Buckeye and
competitor foams as required by NFPA 11 and other foam codes.
FOAM CONCENTRATES
PartNumber
FoamConcentrate Listing/Approval
BFC-1.1 Platinum 1% AFFF Underwriters LaboratoriesBFC-3.1 Platinum 3% AFFF Underwriters LaboratoriesBFC-6.1 Platinum 6% AFFF Underwriters LaboratoriesBFC-33.1 Platinum 3%x3% AR-AFFF Underwriters LaboratoriesBFC-36.1 Platinum 3%x6% AR-AFFF Underwriters LaboratoriesBFC-3LT 3% Low Temperature AFFF Buckeye Quality Assurance
BFC-36LT 3%-6% Low Temperature AR-AFFF Buckeye Quality AssuranceBFC-CA.1 Platinum Class A USDA Forest Service QPLBFC-HX 2.2% High-Expansion Underwriters Laboratories
BFC-3MS 3% Mil Spec AFFF U.S. Navy QPLBFC-3P 3% Protein U.K. Min Def 42-22BFC-6P 6% Protein U.K. Min Def 42-22
BFC-3FP 3% Fluoroprotein Underwriters LaboratoriesBFC-6FP 6% Fluoroprotein Underwriters LaboratoriesBFC-BE Bug-Eye 3% AR-AFFF Underwriters LaboratoriesBFC-VF Virtual Foam Buckeye Quality Assurance
FOAM EQUIPMENT
Buckeye Fire Equipment manufactures a complete line of componentsthat work in conjunction with the foam concentrates to make anunbeatable fire-fighting combination. The selection includesbladder tanks, pump skids, proportioners, eductors, monitors,foam chambers, foam makers, high expansion generators,foam carts, and handline nozzles. Many of the components canbe customized to provide optimal protection for your uniquesituation. All foam system components are precision made fromrugged materials to provide years of dependable service.
Whether it’s a complex engineered system or portable equipment,Buckeye Fire Equipment has the components you need to protectyour valuable assets.
BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 17
MOUNTING HARDWARE
Buckeye Fire Equipment manufactures strong and durable mounting hardware for all of our portable fireextinguishers. The charts below show the corresponding mounting hardware for the extinguishers.
MARINE/VEHICLE BRACKETS
Part No. Model Typical Extinguisher Sizes Used For Reference Diameter700287 A-2 All 2.5 lb. dry chemical and Halotron™ 3.375 in.700270 A-6 All 5 lb. & 5.5 lb. dry chemical and Halotron™ 4.25 in700260 B-6 All 5 lb. & 5.5 lb. dry chemical and Halotron™ 4.25 in.700430 B-12 10 Tall dry chemical 5.125 in.700226 809 10 Tall dry chemical and 5 lb. CO² 5.0 in. – 5.25 in.700228 810 10 lb. & 15 lb. CO², 11 lb. & 15 lb. Halotron 6.5 in. – 7.25 in.700229 811 20S lb. and 30S lb. dry chemical, 20 lb. CO², Class D 7.0 in. – 8.0 in.700230 812 10S dry chemical 6.0 in. – 6.25 in.
WALL HOOKS
Part No. Typical Extinguisher Sizes Used For Reference Diameter700202 2.5 lb., 5 lb., and 5.5 lb. dry chemical and Halotron™ 3.25 in. – 4.25 in.700203 10 Tall & 5 lb. CO 4.75 in. – 5.5 in.700204 10 Short dry chemical 5.0 in. – 6.5 in.700247 20 Short & 30 Short dry chemical, 10 & 15 lb. CO2,
and 11 & 15 lb. Halotron™6.75 in. – 7.5 in.
700249 20 lb. CO2 7.5 in. – 8.0 in.900935 Wet Chemical and Water 7.0 in.
900937 (Stainless Steel) Water Mist 7.0 in.
2
700287
700202 700204 700249
700203 700247 900935900937
700270 700260 700430 700226 700228700229 700230
BuckeyeCOMPLETE:Layout 1 5/25/07 11:03 AM Page 18
Buckeye Fire Equipment
BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 19
Buckeye Fire Equipment110 Kings Road • Kings Mountain, NC 28086
Ph: 704.739.7415 Fax: 704.739.7418www.buckeyef.com
Dry ChemicalPortable and
WheeledExtinguishers
SpecialtyExtinguisherClass “D” & “K”
Water / Water Mist
FoamConcentrates
AndHardware
Restaurant FireSystems
UL-300 Listed
Carbon DioxidePortable and
WheeledExtinguishers
Halotron™ 1Portable and
WheeledExtinguishers
For More Information Please Contact:
BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 20