2-way wireless security suite gs2060/tl260gs product technical training
TRANSCRIPT
![Page 1: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/1.jpg)
2-Way Wireless Security Suite
GS2060/TL260GS Product Technical Training
![Page 2: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/2.jpg)
2-Way Wireless Security Suite
GS2060/TL260GS– Product Overview
![Page 3: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/3.jpg)
2-Way Wireless Security Suite
GS2060
GS2060 GSM/GPRS Wireless Alarm Communicator
Overview:The GS2065 provides primary or backup GSM/GPRS communication for Power Series PC1864/1832/1616 control panels
Specifications:• Dimensions : 3.937"x5.875"x0.625" (100mmx150mmx15mm)• Weight : 310 g• Antenna Gain : 2db• Input Voltage : 11.1 to 12.6 V (from the Panel Bell output)• Current Draw : 65 mA at 12V (400 mA during the GSM transmission)• Operating Environment : 5 º C to 40º C
(40º F to 104º F)
![Page 4: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/4.jpg)
2-Way Wireless Security Suite
GS2060
GS2060 GSM/GPRS Wireless Alarm Communicator
Features:• Back up and primary GSM/GPRS alarm communication• Panel remote uploading/downloading support via GSM/GPRS • Individual Periodic Test Transmission via GSM/GPRS• Supervision heartbeats via GSM/GPRS• 128-bit AES encryption over GSM/GPRS• Full event reporting• SIA format• PC-Link connection• SIM card included• Signal strength and trouble display• Activating and initializing through Connect 24• Quad-Band: 850 MHz, 1900 MHz, 900 MHzand 1800 MHz
![Page 5: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/5.jpg)
2-Way Wireless Security Suite
GS2060
GS2060 GSM/GPRS Wireless Alarm Communicator
Compatible Receivers:Sur-Gard System I Receiver: version 1.10 and higherSur-Gard System II Receiver: version 2.00 and higherSur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver)
Compatible Control Panel & CabinetControl panel: Power Series PC1864/1832/1616 version 4.1 and higherCabinet: PC5003C and PC4050C
Product Model and Accessories:GS2060GS-USA: For US market with AT&T SIM cardGS2060GS-CDN: For Canada market with Roger SIM cardGS-15ANTQ: Antenna Extension Kits with 15 feet cable GS-25ANTQ: Antenna Extension Kits with 25 feet cableGS-50ANTQ: Antenna Extension Kits with 50 feet cable
![Page 6: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/6.jpg)
2-Way Wireless Security Suite
TL260GS
TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator
Overview:The TL260GS is an Internet and GSM/GPRS Dual-Path alarm communication for Power Series PC1864/1832/1616 control panels
Specifications:• Dimensions : 3.937"x5.875"x0.625" (100mmx150mmx18mm)• Weight : 320 g• Antenna Gain : 2db• Input Voltage : 11.1 to 12.6 V (from the Panel Bell output)• Current Draw : 100 mA at 12V (400 mA during the GSM transmission)• Operating Environment : 5 º C to 40º C
(40º F to 104º F)
![Page 7: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/7.jpg)
2-Way Wireless Security Suite
TL260GS
TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator
Features:• Fully redundant Internet and GSM/GPRS dual-path alarm
communication• Integrated call routing• Panel remote uploading/downloading support via GSM/GPRS
and Internet• Individual Periodic Test Transmission via GSM/GPRS and
Internet• Supervision heartbeats via GSM/GPRS and Internet• 128-bit AES encryption via GSM/GPRS and Internet• Full event reporting• SIA format• PC-Link connection• SIM card included• Signal strength and trouble display• Activating and initializing through Connect 24• Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz
![Page 8: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/8.jpg)
2-Way Wireless Security Suite
TL260GS
TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator
Compatible Receivers:Sur-Gard System I Receiver: version 1.10 and higherSur-Gard System II Receiver: version 2.00 and higherSur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver)
Compatible Control Panel:Control panel: Power Series PC1864/1832/1616 version 4.1 and higherCabinet: PC5003C and PC4050C
Product Model and Accessories:TL260GS-USA: For US market with AT&T SIM cardTL260GS-CDN: For Canada market with Roger SIM cardGS-15ANTQ: Antenna Extension Kits with 15 feet cable GS-25ANTQ: Antenna Extension Kits with 25 feet cableGS-50ANTQ: Antenna Extension Kits with 50 feet cable
![Page 9: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/9.jpg)
2-Way Wireless Security Suite
UL Approval List
GS2060 GSM/GPRS Wireless Alarm CommunicatorTL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator
UL Commercial Burglary•Listed as a primary communication channel (heartbeats must be enabled)
•Listed as a back-up in conjunction with the POTS (daily test transmission)
•Used as Dual Signaling Line Communication System (redundancy must be enabled)
•Used as Standard Line Security and Encrypted Line Security System (heartbeats and encryption must be enabled)
UL Residential Burglary and Fire •Listed as a primary communication channel (monthly test transmission)
•Listed as a back-up in conjunction with the DACT (monthly test transmission)
![Page 10: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/10.jpg)
2-Way Wireless Security Suite
ULC Approval List
GS2060 GSM/GPRS Wireless Alarm CommunicatorTL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator
ULC Commercial Burglary and Fire •Listed as a passive communication module with Security Level P1, P2 and P3 (redundancy must be enabled)
•Listed as a active communication module with Security Level A1-A4 (heartbeats and encryption must be enabled)
ULC Residential Burglary and Fire •Listed as a primary communication channel (daily test transmission)
•Listed as a back-up in conjunction with the DACT (daily test transmission)
![Page 11: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/11.jpg)
2-Way Wireless Security Suite
UL/ULC Listed Installation – Commercial
Supervisory/Test Transmission Requirements
Applications CommunicatorSetup Mode
GS2060 TL260GS
Primary Channel
Backup Channel
UL Commercial Burglary Primary 200 ms 200 ms Daily
UL Commercial Burglary Backup Daily Daily Optional
ULC Commercial Fire Active 180 ms 180 ms Daily
ULC Commercial Fire Passive Daily Daily Daily
ULC Commercial Burglary Active 180 ms 180 ms Daily
ULC Commercial Burglary Passive Daily Daily Daily
NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations.
![Page 12: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/12.jpg)
2-Way Wireless Security Suite
UL/ULC Listed Installation – Residential
Supervisory/Test Transmission – Requirements
Applications CommunicatorSetup Mode
GS2060 TL260GS
Primary Channel
Backup Channel
UL Residential Fire Primary Monthly Monthly Monthly
UL Residential Fire Backup Monthly Monthly Optional
UL Residential Burglary Primary Monthly Monthly Monthly
UL Residential Burglary Backup Monthly Monthly Optional
ULC Residential Fire Active Daily Daily Optional
ULC Residential Fire Passive Daily Daily Optional
ULC Residential Burglary Active Daily Daily Optional
ULC Residential Burglary Passive Daily Daily Optional
NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations.
![Page 13: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/13.jpg)
2-Way Wireless Security Suite
GS2060/TL260GS– Installation and programming
![Page 14: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/14.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
BEFORE YOU BEGIN
Have the following ready before installation:
• PC1864/1832/1616 Control panel with backup battery• Battery connection harness• PK5500 keypad with battery • Screwdriver
Prior to installing a GS2060 and TL260GS, contact your monitoring station to determine if it is a master reseller or visit www.connect24.com and become an authorized dealer. In both instances, you will acquire a Profile Number, Installer ID Number and an Installer Password.
Please NOTE: 1. You need to activate the SIM card and initialize the communicator (step 1) 24
HOURS BEFORE INSTALLATION.
2. All options of the communicator only could be programmed through Connect 24
![Page 15: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/15.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Summary of Installation Steps
Step 1 – Initialize an account via Connect 24 Website (www.connect24.com)
Step 2 – Install and wire the communicator to the control panel (on-site)
Step 3 – Load the programming and test for best signal strength location
Step 4 – Program communication options on the control panel via keypad
Step 5 – Test communication
![Page 16: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/16.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 1 – Initialize an account via Connect 24 Website (www.connect24.com)
Login to Connect 24 website by using Installer ID and Password to initialize an account• Select Profile Number• Select Product Model• Enter SIM card number • Enter DNIS number (if necessary)• Enter Account Code• Select GPRS Periodic Test Transmission Interval (if necessary)• Select Supervisory Type (if necessary)• Enable DHCP (if necessary)• Enter IP Address (TL260GS only when the installation is static IP)• Enter Subnet Mask Address (TL260GS only when the installation is static IP)• Enter Gateway Address (TL260GS only when the installation is static IP)• Select Ethernet Periodic Test Transmission Interval (if necessary)• Select Rate Plan• Confirm information and submit activation application
NOTE: You still can remotely change these options later via Connect 24 website.
![Page 17: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/17.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 1 – 1Select Profile Number
Select Profile
![Page 18: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/18.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 1 – 2Select Module Number
Select ProfileSelect Module Number
![Page 19: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/19.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 1 – 3Enter SIM Number
Select ProfileEnter SIM Number
![Page 20: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/20.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 1 – 4• Enter DNIS number • Enter Account Code• Select Supervisory Type• Enable DHCP (if necessary)
Select Profile
Enter DNIS
Enter Account Code
Select Supervisory Type
DHCP Option
![Page 21: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/21.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 1 – 5• Enter IP Address (TL260GS only)• Enter Subnet Mask Address (TL260GS only)• Enter Gateway Address (TL260GS only)
Select Profile
IP Address
Subnet Mask
Gateway
![Page 22: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/22.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 1 – 6• Select Plan Rate
Select Profile
Rate Plan
![Page 23: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/23.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 2 – 1 Install and wire the communicator to the control panel (on-site)
•Assemble the communicator with mounting bracket
![Page 24: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/24.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 2 – 2 Install and wire the communicator to the control panel (on-site)
•Insert the communicator into the cabinet and assemble the antenna
![Page 25: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/25.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 2 – 3 Install and wire the communicator to the control panel (on-site)
•Wire the communicator to control panel
NOTE: See details in product manual for PC1864/1832/1616 control panel
PCLINK Cable Connector•Control panel: Red wire is on the right and black is on the left
•Communicator: Must be reversed (Black wire is on the right and red wire is on the left)
![Page 26: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/26.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 3 – Load the programming and test for best signal strength location
Ensure the SIM card is inserted Power up the control panel
The communicator will be programmed by loading the pre-programmed configuration from Connect 24 automatically
Check Green LEDs. You must achieve full or medium signal strength. See details in product manual.
If signal strength is poor, must relocate the control panel or use an external extension antenna kits
![Page 27: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/27.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 4 – Program communication options on the control panel via keypad
GS2060/TL260GS with PC1864/1832/1616 control panel o Sections [301], [302], [303]: Program Communication Path
• DCAA - Internal (Ethernet 1, Ethernet 2, GPRS 1, GPRS 2)
o Section [350] : Program Communication Format (Communicator)
• (If Option [301] (above) is set to DCAA, Option [350] must be
set to SIA, sub-option 5)
o Sections [351] to [376] : Program Call Direction
o Section [382] : Enable T-LINK Interface (Option [5])
o Section [167] : Enable Communication Wait For ACK (Set to 60 seconds)
o Section [401] : Enable DLS Session Through GPRS or Ethernet (Option [1])
![Page 28: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/28.jpg)
2-Way Wireless Security Suite
Installation
GS2060/TL260GS Installation
Step 5 – Test communication
1. Disconnect incoming phone line from TIP and RING on the control panel 2. Verify that LED 2 is on, this indicate that the unit is active3. Create an alarm transmission 4. Verify alarm transmission by calling monitoring station5. Re-connect the phone line, if necessary
For back-up communication applications, perform steps 1 to 5For primary communication applications, perform steps 3 and 4 only
![Page 29: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/29.jpg)
2-Way Wireless Security Suite
Installation
LED Display
Trouble Status LED (Yellow – first one from the left)
Please see details about the trouble shooting on page 17 in product manual
![Page 30: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/30.jpg)
2-Way Wireless Security Suite
Installation
LED Display
Network Connection Status LED (Red – second one from the left)
LED OFF•No network connection issue present
LED ON•Physical Ethernet cable is not connected•DHCP configuration fails•Fails to get an IP address from the GPRS network•GPRS connections has been reset
LED blinks quickly once•Ethernet transmitting
LDE blinks quickly twice•Ethernet receiving
![Page 31: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/31.jpg)
2-Way Wireless Security Suite
Installation
LED Display
Signal Strength LED 2 (Green – third one from the left)Signal Strength LED 1 (Green – fourth one from the left)
Green LED 2 blinks quickly once•GPRS transmitting
Green LED 2 blinks quickly twice•GPRS receiving
![Page 32: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/32.jpg)
2-Way Wireless Security Suite
Installation
Keypad Trouble Display
Trouble Condition•General System Trouble
Panel Event Buffer Description•T-Link Network Fault/Restore includes
SIM Lock TroubleGSM TroubleEthernet Trouble Connect 24 Configuration Trouble
•T-Link Receiver Trouble/Restore includes Receiver Not Available TroubleReceiver Supervison TroubleFTC Trouble
•T-Link Comm. Fault/Restore includesPanel Absent Trouble
![Page 33: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/33.jpg)
2-Way Wireless Security Suite
GS2060/TL260GS– Applications
![Page 34: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/34.jpg)
2-Way Wireless Security Suite
Applications
GS/IP Call Routing (Internal)
Communicator Controlled Call Routing – Backup (dual-path)
– Redundant (dual-path)
Required ProgrammingPanel Sections [301], [302] and [305]
• Any of them could be programmed as DCAADCAA (default): Ethernet 1 → Ethernet 2 → GRPS 1 → GPRS 2
Communicator Sections [005]Option [4] - Primary and backup path
[ON]: GPRS path primary, Ethernet path backup
[OFF]: Ethernet path primary, GPRS path backup
Option [5] - Redundant between GPRS path and Ethernet path [OFF]: Disable
redundancy[ON]: Enable redundancy
NOTE: “Primary and Backup Path” and “Redundant Communication” options need to be configured during the initialization of the account via Connect 24.
![Page 35: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/35.jpg)
2-Way Wireless Security Suite
Applications
GS/IP Call Routing (Internal)
Backup Mode 1: Ethernet Primary, 4 Receivers
Ethernet Receiver 1
Ethernet Receiver 2
GPRS Receiver 1
GPRS Receiver 2
IP Receiver* 1
IP Receiver 2
IP Receiver 3
IP Receiver 4
Tx 2 failed, TX3
TX 1
Tx 3 failed, Tx4
Tx 1 failed, Tx2
![Page 36: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/36.jpg)
2-Way Wireless Security Suite
Applications
GS/IP Call Routing (Internal)
Backup Mode 2: Ethernet Primary, 2 Receivers
Ethernet Receiver 1
Ethernet Receiver 2
GPRS Receiver 1
GPRS Receiver 2
IP Receiver 1
IP Receiver 2
TX 1
Tx 3 failed, Tx4
Tx 1 failed, Tx2
Tx 2 failed, TX3
![Page 37: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/37.jpg)
2-Way Wireless Security Suite
Applications
GS/IP Call Routing (Internal)
Backup Mode 3: GPRS Primary, 4 Receivers
Ethernet Receiver 1
Ethernet Receiver 2
GPRS Receiver 1
GPRS Receiver 2
IP Receiver 1
IP Receiver 2
IP Receiver 3
IP Receiver 4
Tx 2 failed, TX3
TX 1
Tx 3 failed, Tx4
Tx 1 failed, Tx2
![Page 38: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/38.jpg)
2-Way Wireless Security Suite
Applications
GS/IP Call Routing (Internal)
Backup Mode 4: GPRS Primary, 2 Receivers
Ethernet Receiver 1
Ethernet Receiver 2
GPRS Receiver 1
GPRS Receiver 2
IP Receiver 1
IP Receiver 2
TX 1
Tx 3 failed, Tx4
Tx 1 failed, Tx2
Tx 2 failed, TX3
![Page 39: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/39.jpg)
2-Way Wireless Security Suite
Applications
GS/IP Call Routing (Internal)
Redundant Mode: 4 Receivers – (Redundancy between GSM/GPRS path and Ethernet/Internet path)
Ethernet Receiver 1
Ethernet Receiver 2
GPRS Receiver 1
GPRS Receiver 2
IP Receiver 1
IP Receiver 2
IP Receiver 3
IP Receiver 4
TX1, GPRS path
TX 1, Ethernet path
TX 1 failed, TX 2 via GPRS path
TX1 failed, TX 2 via Ethernet path
NOTE: The application requires 4 different SG receivers or SG-DLR3 IP line cards
![Page 40: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/40.jpg)
2-Way Wireless Security Suite
Applications
Other Applications
Periodic Test transmission•Individual periodic test via GPRS and Ethernet•Daily, Weekly and Monthly Interval•Configured during the initialization of the account via Connect 24
Encryption•128 Bit AES Encryption •Turned on by central monitoring station Sur-Gard receiver•Encrypted communications enabled after next event sent to the receiver
NOTE: Enabling this feature will require more data usage.
Read-only Options from Keypad•Read all the options of the communicator from LCD keypad•Control panel option [851]
![Page 41: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/41.jpg)
2-Way Wireless Security Suite
Applications
Other Applications
Power Save Mode•Extend the battery duration when an AC power loss on control panel•Ethernet functionality turned off until a new event need to be transmitted•Network Connections LED: OFF•Incoming DLS connection will not be possible
Hardware Default •Reset the programming options to the factory setting (default values)NOTE: Please see details in product manual
Software Update •Update the firmware through DLS IV locally via PCLINK•Update the firmware through DLS IV remotely via Ethernet/Internet (TL260GS only)
![Page 42: 2-Way Wireless Security Suite GS2060/TL260GS Product Technical Training](https://reader035.vdocuments.site/reader035/viewer/2022062800/56649e155503460f94affeec/html5/thumbnails/42.jpg)
2-Way Wireless Security Suite
Applications
SIA Report Code
Event SIA Data Code SIA Address Field Panel Absent Trouble ET 001Panel Absent Trouble Restore ER 001Radio Activation Restore RS 001Ethernet 1 Test Transmission RP 001GPRS 1 Test Transmission RP 003GPRS 2 Test Transmission RP 004FTC Restore YK 001
Example: Nri0 ET001 N= New Eventri0=Partition/Area identifierET= Panel Absent Restore 001=Zone 001
NOTE: GPRS 2 Test Transmission will only be sent when two different APNs are programmed.