1record descriptions -...

25
Internal information DOCUMENTATION 1(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File IBM Jörgen Skohg 2011-07-13 S c:\backup_mh\documents\t00001_s.doc 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information - create C Basic information - maintain D Receiver information E Synonym serial number information F External serial number information G Structure correction External H Request IBMS I Result IBMS K Customer information L Site information P Package information Q SIM Lock Keys - create R SIM Lock Keys - change S Structure information T Swap Child U Structure correction X Request for Basic information (to local system) Y Request for Basic information (to Tracy) Z Scrap individuals LOG OF CHANGES Object Type of changes Date Revision G- and U-record New record types 2002-05-27 D D-record Internal record type 2002-05-27 D K-record Further information; field “Company code” 2002-09-11 E D-record New fields in the record 2003-01-22 F K-record Fields taken out from the record: ’Site acceptance date’ and ‘Warranty expire date’ New fields in the record: ’Sales group’, Shipment number’, ‘End customer name’, ‘End customer id’, Customer name’, ‘Sales order number’, ‘GSF-reference’ and ‘Purchase order number’ 2003-01-27 G L-record New fields in record: Installed date and End customer name 2003-02-17 H S-record New field in record: Replace date 2003-02-17 H T-record New field in record: Replace date 2003-02-17 H T-record Correction: description Replace date 2004-04-14 I Y-record New fields: TYPE-C, TYPE-L, REF-NO, SYSTEM 2004-05-03 J D-record Correction of length of mail address field 2004-11-26 D-record USERID replaced by PARM (general parameter) 2005-02-11 K B-record, C-record New field: CNTRY-CD (Origin) 2006-10-31 L Y-record TYPE-L replaced by Separator (for MACaddress) 2007-02-22 M P-record New record type added 2007-12-28 N

Upload: truongmien

Post on 01-Apr-2018

234 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

1(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

1RECORD DESCRIPTIONS: Record type Description

A Receiver record B Basic information - create C Basic information - maintain D Receiver information E Synonym serial number information F External serial number information G Structure correction External H Request IBMS I Result IBMS K Customer information L Site information P Package information Q SIM Lock Keys - create R SIM Lock Keys - change S Structure information T Swap Child U Structure correction X Request for Basic information (to local system) Y Request for Basic information (to Tracy) Z Scrap individuals

LOG OF CHANGES Object Type of changes Date Revision G- and U-record New record types 2002-05-27 D D-record Internal record type 2002-05-27 D K-record Further information; field “Company code” 2002-09-11 E D-record New fields in the record 2003-01-22 F K-record Fields taken out from the record:

’Site acceptance date’ and ‘Warranty expire date’ New fields in the record: ’Sales group’, Shipment number’, ‘End customer name’, ‘End customer id’, Customer name’, ‘Sales order number’, ‘GSF-reference’ and ‘Purchase order number’

2003-01-27 G

L-record New fields in record: Installed date and End customer name

2003-02-17 H

S-record New field in record: Replace date 2003-02-17 H T-record New field in record: Replace date 2003-02-17 H T-record Correction: description Replace date 2004-04-14 I Y-record New fields: TYPE-C, TYPE-L, REF-NO, SYSTEM 2004-05-03 J D-record Correction of length of mail address field 2004-11-26 D-record USERID replaced by PARM (general parameter) 2005-02-11 K B-record, C-record New field: CNTRY-CD (Origin) 2006-10-31 L Y-record TYPE-L replaced by Separator (for MACaddress) 2007-02-22 M P-record New record type added 2007-12-28 N

Page 2: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

2(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

K-record GSF reference replaced by Package ID 2008-03-03 N S-record Information changed for REPLACE_DT 2008-03-26 O Q-record New record type 2008-06-10 P R-record New record type 2008-06-10 P H-record New record type 2010-06-14 Q I-Record New record type 2010-06-14 Q B-, C-, E-, K-, L-, P-, S-, T-, X-, Y- and Z-records

Change of records caused by Nortel project. Ser_No field extended to 35 characters New field: CIN (15 characters)

2011-04-28 R

P-Record Change caused by Nortel project. Amount of ser-no’s reduced from 5 to 2 in record

2011-04-28 R

S-Record Change caused by Nortel project. Amount of included ser-no’s reduced from 5 to 1.

2011-04-28 R

P- and X-record Corrections 2011-07-13 S

Page 3: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

3(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

RECEIVER INFORMATION: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = A M REC_UNIT Receiving unit (factory) 2 6 A Unit code M SEND_DT Date for sending information 8 10 A = YYYY-MM-DD M FILLER Filler 18 3 A Spaces M Total record length: 20 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”A”. • REC_UNIT – must be an approved unit code. • SEND_DT – must be a valid date. NOTE: Tracy only uses this record type, for sending files via EDI and T2M.

Page 4: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

4(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

BASIC INFORMATION – create: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = B M FILLER FILLER 2 13 A Spaces M MFG_UNIT Manufacturing unit 15 6 A Unit code M PRNO Product number (without R-state) 21 24 A M PROREV Product revision state 45 7 A M MFG_DT Manufacturing date 52 8 A = YYYYMMDD M FILLER FILLER 60 6 A Spaces M EXMPN_IND Exemption indicator 66 1 A = Y(es) or N(o) M SEND_SYSTEM Sending system 67 8 A System name M SEND_UNIT Sending unit (company) 75 6 A Unit code M CNTRY-CD Country code 81 2 A Origin code M SER_NO Serial number 83 35 A M CIN CIN 118 15 A O FILLER Filler 133 18 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”B”. • MFG_UNIT – must be a valid unit code according to table for unit codes. • PRNO – validated to PRIM. • PROREV – validated to PRIM. • MFG_DT – must be a valid date. • DEST – must be a valid unit code according to table for unit codes (if not space). • EXMPN_IND – must be Y or N. • CNTRY-CD (out from Tracy) • SER_NO – Validation according to rules in format table TRULE. • FUNC-DES (out from Tracy to TULP )

Page 5: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

5(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

BASIC INFORMATION – maintain + unscrap. Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = C M FILLER FILLER 2 13 A Spaces M MFG_UNIT Manufacturing unit 15 6 A Unit code C PRNO Product number (without R-state) 21 24 A C PROREV Product revision state 45 7 A C DEST Destination 52 6 A Unit code C EXMPN_IND Exemption indicator 58 1 A = Y(es) or N(o) C REPAIR_CTR Repair centre 59 6 A Unit code C SEND_SYSTEM Sending system 65 8 A System name M SEND_UNIT Sending unit (company) 73 6 A Unit code M CNTRY_CD Country code 79 2 A Origin code C SER_NO Serial number 81 35 A M CIN CIN 116 15 A O FILLER Filler 131 20 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”C”. • MFG_UNIT – must be a valid unit code according to table for unit codes (if not space). • PRNO – validated to PRIM (if not space). • PROREV – validated to PRIM (if not space). • DEST – must be a valid unit code according to table for unit codes (if not space). • EXMPN_IND – must be Y or N (if not space). • REPAIR_CTR – must be a valid unit code according to table for unit codes (if not space). • CNTRY_CD (Out from Tracy) • SER_NO – Validation according to rules in format table TRULE.

Page 6: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

6(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

RECEIVER INFORMATION: Data name Description Pos No Type Remarks Req. REC-TYPE Record type 1 1 A = D M MAIL-ADDR Mail address 2 78 A C MAIL-SUBJ Mail subject 80 30 A M FILE-EXT File extension type 110 3 A M ZIP-FLAG ZIP flag 113 1 A “Y” or “N” M ATTACH-FLAG Attach flag 114 1 A “Y” or “N” M UNIT Unit 115 6 A C APPL Application 121 10 A C PARM Parameter 131 15 A C SE-IND Start/end indicator 146 5 A = “START” or “END” M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC-TYPE – must be equal to ”D”. • MAIL-SUBJ – must not be space • FILE-EXT – must be “CSV” or “TXT” • ZIP-FLAG – must be “Y” or “N” • ATTACH-FLAG – must be “Y” or “N” • • Conditional fields • MAIL-ADDR – can be space if UNIT and APPL are added (mail address is unknown by IBM appl.) • UNIT – Is used when mail address is unknown by IBM appl. (known by T2M). • APPL – used when UNIT is used • PARM – general parameter that can be used with APPL. NOTE: Tracy only uses this record type, for sending files via T2M.

Page 7: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

7(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

SYNONYM SERIAL NUMBER INFORMATION: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = E M ACTION Action code 2 1 A A = Add

D = Delete M

FILLER Filler 3 13 A Space M SYN_SER_NO Synonym serial number 16 35 A M SER_NO_TP Serial number type code 51 1 A M SEND_SYSTEM Sending system 52 8 A System name M SEND_UNIT Sending unit (company) 60 6 A Unit code M SER_NO Serial number 66 35 A M CIN CIN 101 15 A O FILLER Filler 116 35 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”E”. • ACTION – must be ”A” or ”D”. • SYN_SER_NO – no validation. • SER_NO_TP – must be a valid value according to a table for serial number type codes. • SER_NO – Validation according to rules in format table TRULE.

Page 8: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

8(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

EXTERNAL SERIAL NUMBER INFORMATION: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = F M ACTION Action code 2 1 A A = Add

D = Delete M

SER_NO Serial number 3 13 A M EXT_SER_NO External serial number 16 35 A M PRNO Product number 51 35 A Can be external O SUPPL Supplier 86 35 A O SEND_SYSTEM Sending system 121 8 A System name M SEND_UNIT Sending unit (company) 129 6 A Unit code M FILLER Filler 135 16 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”F”. • ACTION – must be ”A” or ”D”. • SER_NO – Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or A-Z

(except O and I). Character 11-13 must be spaces. • EXT_SER_NO – no validation. • PRNO – no validation. • SUPPL – no validation.

Page 9: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

9(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

STRUCTURE CORRECTION EXTERNAL: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = G M SER_NO Serial number 2 13 A M EXT_SER_NO External serial number 15 35 A M PRNO Product number 50 35 A Can be external O SUPPL Supplier 85 35 A O SEND_SYSTEM Sending system 120 8 A System name M SEND_UNIT Sending unit (company) 128 6 A Unit code M FILLER Filler 134 17 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”G”. • SER_NO – Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or A-Z

(except O and I). Character 11-13 must be spaces. • EXT_SER_NO – no validation. • PRNO – no validation. • SUPPL – no validation.

Page 10: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

10(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

REQUEST INSTALLED BASE: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = H M SER_NO Serial number 2 13 A M UNIT_CD Factory code 15 6 A O SEND_SYSTEM Sending system 21 8 A System name M FILLER Filler 29 22 A Spaces M Total record length: 50 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to”H”. • SER_NO – Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or A-Z

(except O and I). Character 11-13 must be spaces. • UNIT_CD – must be an approved unit code.

Page 11: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

11(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

RESULT INSTALLED BASE: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = I M LEVEL Structure Level 2 1 A 0 – 8 M SER_NO Serial number 3 13 A M PROD_NO Product Number 16 24 A C R_STATE Revision State 40 7 A C MFG_DT Manufacturing Date 47 10 A YYYY-MM-DD C MSG Message 57 40 A C FILLER Filler 97 24 A Spaces M Total record length: 120 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to”I”. • SER_NO – Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or A-Z

(except O and I). Character 11-13 must be spaces.

Page 12: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

12(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

CUSTOMER INFORMATION: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = K M FILLER FILLER 2 13 A Spaces M COMP_CD Company code 15 4 A e.g. ”2011” M CUST_DELIV_NO Customer delivery number 19 15 A M CUST_ID Customer identification 34 15 A M CUST_CNTRY_CD Customer country code 49 2 A M ETA_SHP_DT Estimated shipment date 51 8 A = YYYYMMDD C SHP_DT Shipment date 59 8 A = YYYYMMDD C SITE_LOC_ID Site location identification 67 35 A C SITE_CNTRY_CD Site country code 102 2 A C SEND_SYSTEM Sending system 104 8 A System name M SEND_UNIT Sending unit (company) 112 6 A Unit code M SALES_GRP Sales group 118 3 A C PRNO Product number (no R-state) 121 24 A M SHP_NO Shipment number 145 10 A M END_CUST_NM End customer name 155 40 A C END_CUST_ID End customer identification 195 15 A C CUST_NM Customer name 210 40 A M SALES_ORD_NO Sales order number 250 10 A C PACK_ID Package Identity 260 24 A C PURCH_ORD_NO Purchase order number 284 35 A C SER_NO Serial number 319 35 A M CIN CIN 354 15 A O Total record length: 368 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”K”. • COMP_CD – must be a valid company code for the delivering unit. • CUST_DELIV_NO – no validation. • CUST_ID – no validation. • CUST_CNTRY_CD – must be a valid country code according to table for country codes. • SITE_LOC_ID – no validation. • SITE_CNTRY_CD – must be a valid country code according to table for country codes. • ETA_SHP_DT – must be a valid date. Mandatory if SHP_DT = space. • SHP_DT – must be a valid date. Mandatory if ETA_SHP_DT = space. • SALES_GRP – no validation • PRNO – no validation • SHP_NO – no validation • END_CUST_NM – no validation • END_CUST_ID – no validation • CUST_NM – no validation • SALES_ORD_NO – no validation • PURCH_ORD_NO – no validation

Page 13: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

13(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

• PACK_ID - no validation, but must be present if SER_NO = Space • SER_NO – Validation according to rules in format table TRULE.

Should be space if PACK_ID is present

Page 14: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

14(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

SITE INFORMATION: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = L M FILLER Filler 2 13 A Spaces M SITE_LOC_ID Site location identification 15 35 A M SITE_CNTRY_CD Site country code 50 2 A M SITE_ACC_DT Site acceptance date 52 8 A C WRNTY_EXPIR_DT Warranty expire date 60 8 A C SEND_SYST Sending system 68 8 A System name M SEND_UNIT Sending unit (company) 76 6 A Unit code M INST_DT Installed date 82 8 A YYYYMMDD C SITE_LOC_SER_NO Site location serial number 90 35 A M CIN CIN 125 15 A O FILLER Filler 140 11 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE - must be equal to ”L”. • SITE_LOC_ID - no validation • SITE_CNTRY_CD - must be a valid country code according to table for country codes. • SITE_ACC_DT – must be a valid date. • WRNTY_EXPIR_DT – must be a valid date. • INSTALL_DT – must be a valid date • SER_NO – Validation according to rules in format table TRULE

Page 15: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

15(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

PACKAGE INFORMATION: REC_TYPE Record type 1 1 A = P M ACTION Action code 2 1 A A = Add

D = Delete M

PACK_ID Package identification 3 24 A M SER_NO_1 Serial number 1 27 35 A M CIN_1 CIN 1 62 15 A O SER_NO_2 Serial number 2 77 35 A O CIN_2 CIN 2 112 15 A O FILLER Filler 127 4 A Spaces M SEND_SYSTEM Sending system 131 8 A System name M SEND_UNIT Sending unit (company) 139 6 A Unit code M FILLER Filler 145 6 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”P”. • ACTION – must be ”A” or ”D”. • SER_NO – Validation according to rules in format table TRULE.

Page 16: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

16(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

SIM LOCK KEY INFORMATION - create: Data name Description Pos No Type Remarks Req. REC_TP Record Type 1 1 A = Q M SER_NO Serial Number 2 13 A M L_KEY_1 Lock Key 1 15 16 A M L_KEY_DESC_1 Lock Key Desc 1 31 10 A = CLCKL M UL_KEY_1 Unlock Key 1 41 16 A M UL_KEY_DESC_1 Unlock Key Desc 1 57 10 A = CLCKU M ACT_KEY_FLAG_1 Active Key Flag 1 67 1 A M L_KEY_2 Lock Key 2 68 16 A M L_KEY_DESC_2 Lock Key Desc 2 84 10 A = ESLCKL M UL_KEY_2 Unlock Key 2 94 16 A M UL_KEY_DESC_2 Unlock Key Desc 2 110 10 A = ESLCKU M ACT_KEY_FLAG_2 Active Key Flag 2 120 1 A M L_KEY_3 Lock Key 3 121 16 A M L_KEY_DESC_3 Lock Key Desc 3 137 10 A = NLCKL M UL_KEY_3 Unlock Key 3 147 16 A M UL_KEY_DESC_3 Unlock Key Desc 3 163 10 A = NLCKU M ACT_KEY_FLAG_3 Active Key Flag 3 173 1 A M L_KEY_4 Lock Key 4 174 16 A M L_KEY_DESC_4 Lock Key Desc 4 190 10 A = NSLCKL M UL_KEY_4 Unlock Key 4 200 16 A M UL_KEY_DESC_4 Unlock Key Desc 4 216 10 A = NSLCKU M ACT_KEY_FLAG_4 Active Key Flag 4 226 1 A M L_KEY_5 Lock Key 5 227 16 A M L_KEY_DESC_5 Lock Key Desc 5 243 10 A = PCKL M UL_KEY_5 Unlock Key 5 253 16 A M UL_KEY_DESC_5 Unlock Key Desc 5 269 10 A = PCKU M ACT_KEY_FLAG_5 Active Key Flag 5 279 1 A M L_KEY_6 Lock Key 6 280 16 A M L_KEY_DESC_6 Lock Key Desc 6 296 10 A = SPLCKL M UL_KEY_6 Unlock Key 6 306 16 A M UL_KEY_DESC_6 Unlock Key Desc 6 322 10 A = SPLCKU M ACT_KEY_FLAG_6 Active Key Flag 6 332 1 A = D or E M SEND_UNIT Sending unit 333 6 A Factory Code M Total record length: 338 Ch M = Mandatory VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”Q”.

Page 17: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

17(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

• SER_NO – Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or A-Z (except O and I). Character 11-13 must be spaces.

• L_KEY – Must be 16 characters long, only digits. • L_KEY_DESC – Must be in the following list: “NLCKL”, “NSLCKL”, “SPLCKL”, “PCKL”,

“CLCKL”, “ESLCKL” • UL_KEY – Must be 16 characters long, only digits. • UL_KEY_DESC – Must be in the following list: “NLCKU”, “NSLCKU”, “SPLCKU”, “PCKU”,

“CLCKU”, “ESLCKU” • ACT_KEY_FLAG – Must be “D” or “E” (Disabled or Enabled). • SEND_UNIT – Must be an approved factory code, according to Factory Code Table (TFACT).

Page 18: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

18(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

SIM LOCK KEY INFORMATION - change: Data name Description Pos No Type Remarks Req. REC_TP Record Type 1 1 A = R M SER_NO Serial Number 2 13 A M L_KEY_1 Lock Key 1 15 16 A M L_KEY_DESC_1 Lock Key Desc 1 31 10 A = CLCKL M UL_KEY_1 Unlock Key 1 41 16 A M UL_KEY_DESC_1 Unlock Key Desc 1 57 10 A = CLCKU M ACT_KEY_FLAG_1 Active Key Flag 1 67 1 A M L_KEY_2 Lock Key 2 68 16 A M L_KEY_DESC_2 Lock Key Desc 2 84 10 A = ESLCKL M UL_KEY_2 Unlock Key 2 94 16 A M UL_KEY_DESC_2 Unlock Key Desc 2 110 10 A = ESLCKU M ACT_KEY_FLAG_2 Active Key Flag 2 120 1 A M L_KEY_3 Lock Key 3 121 16 A M L_KEY_DESC_3 Lock Key Desc 3 137 10 A = NLCKL M UL_KEY_3 Unlock Key 3 147 16 A M UL_KEY_DESC_3 Unlock Key Desc 3 163 10 A = NLCKU M ACT_KEY_FLAG_3 Active Key Flag 3 173 1 A M L_KEY_4 Lock Key 4 174 16 A M L_KEY_DESC_4 Lock Key Desc 4 190 10 A = NSLCKL M UL_KEY_4 Unlock Key 4 200 16 A M UL_KEY_DESC_4 Unlock Key Desc 4 216 10 A = NSLCKU M ACT_KEY_FLAG_4 Active Key Flag 4 226 1 A M L_KEY_5 Lock Key 5 227 16 A M L_KEY_DESC_5 Lock Key Desc 5 243 10 A = PCKL M UL_KEY_5 Unlock Key 5 253 16 A M UL_KEY_DESC_5 Unlock Key Desc 5 269 10 A = PCKU M ACT_KEY_FLAG_5 Active Key Flag 5 279 1 A M L_KEY_6 Lock Key 6 280 16 A M L_KEY_DESC_6 Lock Key Desc 6 296 10 A = SPLCKL M UL_KEY_6 Unlock Key 6 306 16 A M UL_KEY_DESC_6 Unlock Key Desc 6 322 10 A = SPLCKU M ACT_KEY_FLAG_6 Active Key Flag 6 332 1 A = D or E M SEND_UNIT Sending unit 333 6 A Factory Code M Total record length: 338 Ch M = Mandatory VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”R”.

Page 19: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

19(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

• SER_NO – Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or A-Z (except O and I). Character 11-13 must be spaces.

• L_KEY – Must be 16 characters long, only digits. • L_KEY_DESC – Must be in the following list: “NLCKL”, “NSLCKL”, “SPLCKL”, “PCKL”,

“CLCKL”, “ESLCKL” • UL_KEY – Must be 16 characters long, only digits. • UL_KEY_DESC – Must be in the following list: “NLCKU”, “NSLCKU”, “SPLCKU”, “PCKU”,

“CLCKU”, “ESLCKU” • ACT_KEY_FLAG – Must be “D” or “E” (Disabled or Enabled). • SEND_UNIT – Must be an approved factory code, according to Factory Code Table (TFACT).

Page 20: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

20(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

STRUCTURE INFORMATION: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = S M ACTION Action code 2 1 A A = Add

D = Delete M

SER_NO_OWNER Serial number consists of 3 35 A M CIN_OWNER CIN consists of 38 15 A O SER_NO_INCLUD Serial number included in 53 35 A M FILLER Filler 88 1 A Spaces M SEND_UNIT Sending unit (company) 89 6 A Unit code M SEND_SYSTEM Sending system 95 8 A System name REPLACE_DT Replaced date 103 8 A YYYYMMDD C CIN_ INCLUDE CIN included in 111 15 A O FILLER Filler 126 25 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”S”. • ACTION – must be ”A” or ”D”. • SER_NO_OWNER – Validation according to rules in format table TRULE. • SER_NO_INCLUD - Validation according to rules in format table TRULE.

REPLACE_DT – must be a valid date

Page 21: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

21(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

SWAP CHILD: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = T M FILLER Filler 2 26 A Spaces M SEND_SYSTEM Sending system 28 8 A System name M SEND_UNIT Sending unit (company) 36 6 A Unit code M REPLACE_DT Replaced date 42 8 A YYYYMMDD C SER_NO Serial number 50 35 A M CIN CIN serno 85 15 A O SER_NO_SWAP Serial number swap 100 35 A M CIN_SWAP CIN swap 135 15 A O FILLER Filler 150 1 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”T”. • REPLACE_DT – must be a valid date • SER_NO – Validation according to rules in format table TRULE • SER_NO_SWAP – Validation according to rules in format table TRULE

Page 22: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

22(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

STRUCTURE CORRECTION: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = U M SER_NO_OWNER Serial number consists of 2 13 A M SER_NO_INCLUD Serial number included in 15 13 A M SEND_SYSTEM Sending system 28 8 A System name M SEND_UNIT Sending unit (company) 36 6 A Unit code M FILLER Filler 42 109 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”U”. • SER_NO_OWNER - Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or

A-Z (except O and I). Character 11-13 must be spaces. • SER_NO_INCLUD - Character 1-3 must be an approved unit code. Character 4-10 must be 0-9 or

A-Z (except O and I). Character 11-13 must be spaces. • SER_NO_INCLUDE - must not be the same number as SER_NO_OWNER.

Page 23: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

23(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

REQUEST (FROM TRACY TO LOCAL SYSTEMS): Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = X M SER_NO Serial number 2 35 A M CIN CIN 37 15 A O FILLER Filler 52 99 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional

Page 24: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

24(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

REQUEST (FROM LOCAL SYSTEMS TO TRACY): Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = Y M FILLER Filler 2 13 A M SEND_UNIT Sending unit (company) 15 6 A M TYPE_B Flag for B-record 21 1 A Y(es) or N(o) M TYPE_E Flag for E-record 22 1 A Y(es) or N(o) M TYPE_F Flag for F-record 23 1 A Y(es) or N(o) M TYPE_S Flag for S-record 24 1 A Y(es) or N(o) M NO_LEVELS Number of structure levels 25 1 A 1 = one level

2 = two levels 3 = three levels A = all levels

M

TYPE-C Flag for C-record 26 1 A Y or N or space C SEPARATOR Separator used for MACaddr. 27 1 A “-“, “:” or space C REF-NO Reference number 28 16 A Internal use SEND-SYST Sending system 44 7 A System name O SER_NO Serial number 51 35 A M CIN CIN 86 15 A O Total record length: 100 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”Y”. • SEND_UNIT - must be an approved unit code. • TYPE_B – must be ”Y” or ”N”. • TYPE_E – must be ”Y” or ”N”. • TYPE_F – must be ”Y” or ”N”. • TYPE_S – must be ”Y” or ”N”. • NO_LEVELS - must be ”1” or ”A”, if TYPE_S = ”Y”. Must be space, if TYPE_S = ”N”. • TYPE_C – can be ”Y” or ”N” or space. • SEPARATOR – can be ”-” or ”:” or space (means No Separator). • REF-NO – for internal use, should be space. • SEND-SYST – name of the sending system (could be left with spaces). • SER_NO – Validation according to rules in format table TRULE

Page 25: 1RECORD DESCRIPTIONS - Ericssontracy.ericsson.net/.../Record_Descriptions--Serial...35_characters.pdf · 1RECORD DESCRIPTIONS: Record type Description A Receiver record B Basic information

Internal information

DOCUMENTATION

25(25) Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.

IBM Kjell Gustafson BCT/I/ATT-00:00001 Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File

IBM Jörgen Skohg 2011-07-13 S

c:\backup_mh\documents\t00001_s.doc

SCRAP INDIVIDUALS: Data name Description Pos No Type Remarks Req. REC_TYPE Record type 1 1 A = Z M FILLER Filler 2 13 A M SEND_SYSTEM Sending system 15 8 A e.g. ”TRACER” M SEND_UNIT Sending unit (company) 23 6 A Unit code M SER_NO Serial number 29 35 A M CIN CIN 64 15 A O FILLER Filler 79 72 A Spaces M Total record length: 150 Ch M = Mandatory C = Conditional O = Optional VALIDATION: • Mandatory fields. • REC_TYPE – must be equal to ”Z”. • SER_NO – Validation according to rules in format table TRULE

Must be found in Tracy.