Page 1: 1678 Metro Core Connect

1678 Metro Core Connect

Page 2: 1678 Metro Core Connect

1678 Metro Core Connect page - 2All rights reserved © 2002, Alcatel

Today’s Metro-Core & Core networks

ADM HO

2.5G Metro Ring

SP Office/

Gateway

10G

Metro/Core

Rings

10G Optical Core

ADM HOADM HO

ADM HO/LO

Cross-ConnectWDM

10G

Metro/Core

Rings

Page 3: 1678 Metro Core Connect

1678 Metro Core Connect page - 3All rights reserved © 2002, Alcatel

Alcatel Metro-Core & Core Node solution

Converged data layer

…. Making your networks profitable

1678MCC

Optical Cross

Connects to manage

meshed networks

Full carrier-

grade network

Management

of Multiple

Services

GMPLS

interworking to

save network costs

Bandwidth on Demand

to manage uncertain

traffic needs

SDH HO / LO

matrix

Layer2

switch

Lambda switch

WD

M

WD

M

GMPLS/ASON

control plane

Page 4: 1678 Metro Core Connect

1678 Metro Core Connect page - 4All rights reserved © 2002, Alcatel

The drivers

> Minimize CAPEX & OPEX

• New technology allows to compact huge number of interfaces in

• Central office space reduction

• VSR optics

> Improve flexibility

• pay-as-you-grow approach (from 1024xVC4 to 4096xVC4 in the same shelf)

• pay & install only what you need (SFP plug-in optics)

• SDH and Lambda switch using same hardware

> Offer new services / new generation features

• multi-service approach (integrated data functionalities)

• GMPLS control plane for automatic BOnD and network restoration

Page 5: 1678 Metro Core Connect

1678 Metro Core Connect page - 5All rights reserved © 2002, Alcatel

Alcatel solution ready in 2003

ADM HO Broadband DXCEvolution driven by technology:

dramatic component size reduction

mainly optical

1678 MCCSingle/Multi ADM

&

Broadband DXC

collapsed in ONE shelf

Cooling subsystem

Eq

uic

o_

A &

Con

gi

MA

TR

IX 4

096 (

Copy

A)

MA

TR

IX 4

096 (

Copy

B)P

ow

er

Eq

uic

o_

B &

Se

rgi

Po

we

r

Cooling subsystem

Page 6: 1678 Metro Core Connect

1678 Metro Core Connect page - 6All rights reserved © 2002, Alcatel

1678 MCC – Network positioning

Core /

Backbone

Metro

Core

Metro Access

OED

OEDOED

HO ADM

HO ADM

HO ADM

ATM

ET

H

class 4

class 5

voice

voice

DS1

DS3

FE / GE

ET

H

5 km

30 km

100 km

1000 km

ATM

ET

H

ET

H

1.

2.

1678 MCC

• Multiple rings termination

• Multi-ring switching

• Mesh

• GMPLS mesh

• Restoration mesh

Page 7: 1678 Metro Core Connect

1678 Metro Core Connect page - 7All rights reserved © 2002, Alcatel

1678 MCC – product positioning

1

Traditional Ring:

• Stacked 2.5, 10G rings in metro-core

• Multi-ring termination (DCS) in metro-core (2.5G - 40G)

2 Compact BB DCS for switching capacity up to 4K STM1-eq.

Optical switch in OTH core backbone.

Meshed network:

• Centralized and distributed Restoration

• GMPLS for dynamic bandwidth allocation

Network

positioning

Page 8: 1678 Metro Core Connect

1678 Metro Core Connect page - 8All rights reserved © 2002, Alcatel

1678 MCC – benefits in the networks

> Office modernization

• ADM and BB-DXC in one only box

• 60% to 80% price reduction with respect to old gen DCS

• No longer multi-rack configurations: 4K capacity in one compact shelf

> Networks simplification

• Only one NE and one Network Layer for Network Management

• Restoration CAPEX reduction due to port savings

• Automatic bandwidth allocation & distributed protection save Network operators’ manual intervention

• Integrated data functionalities (GbE ptp and L2 switch)

Page 9: 1678 Metro Core Connect

1678 Metro Core Connect page - 9All rights reserved © 2002, Alcatel

End-to-end provisioning Challenges

“Delays in provisioning have been attributed to the manual process involvedin formulating routes based on specific constraints, determining if there is enough capacity to support the route, and manually provisioning each segment of the route. Historically these functions have been manually supported by network operators andplanners and have been supplemented by network management systems.” (RHK)

Page 10: 1678 Metro Core Connect

1678 Metro Core Connect page - 10All rights reserved © 2002, Alcatel

Over 300

In-Service

10 European

In-Service

Interop

Validated

Lab

Demonstration

Network optimization: how to bring flexibility in SDH

> Traditional SDH/SONET

• Fixed bandwidth (STSx granularity)

• End to End provisioning (Point & Click)

> Virtual Optical Networks

• Flexible bandwidth & routing

• “Customer” monitoring and/or (re)provisioning

> Bandwidth “on Demand”

• Dynamic bandwidth & routing

• GMPLS (OIF-UNI) based interfacing

• Overlay

> Dynamic peer-to-peer

• GMPLS (Control Plane)

Page 11: 1678 Metro Core Connect

1678 Metro Core Connect page - 11All rights reserved © 2002, Alcatel

Fully GMPLS enabled (UNI and NNI)

End-to-End solution across GMPLS networks and today’s deployed networks

Multi-vendor and Multi-carrier solution (at UNI and NNI)

New role of NMS

Co-ordination across Data and Optical layers and Unified NMSs

Support of overlay and/or hybrid models

Alcatel

1355 BonD

1300 -seriesData NMS

7770 RCPO-UNI

GMPLS

network OIF-UNI

OIF UNI

NNINNI

NNI

1678 Metro Core Connect

7670 ATM

Switching

7770

IP Routing

Today’s Transport

Network

Alcatel evolution to ION

Riverstone

MPLS

1678 Metro Core Connect

Page 12: 1678 Metro Core Connect

1678 Metro Core Connect page - 12All rights reserved © 2002, Alcatel

Office modernization – ADM replacement

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

2/4F 10Gw/ drops

Main

shelf

2/4F 10Gw/ drops

Multiple racks required per stationTypical central office station today

1678 MCC

ONE 300x600 rack required per station

1678

MCC

1678

MCC

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

4F 10Gring

Main

shelf

Tribshelf

Main

shelf

2/4F 10Gw/ drops

Main

shelf

2/4F 10Gw/ drops

Page 13: 1678 Metro Core Connect

1678 Metro Core Connect page - 13All rights reserved © 2002, Alcatel

Office modernization – Old generation DCSreplacement

1678MCC

4K STM-1eq. capacity

4 racks 600x600 required4K STM-1eq. capacity

1/6 rack 600x600 required

CS

Matrix

B

I/O

Shelf

I/O

Shelf

CS

Matrix

A

I/O

Shelf

I/O

Shelf

Page 14: 1678 Metro Core Connect

1678 Metro Core Connect page - 14All rights reserved © 2002, Alcatel

1678 MCC – matrixes & I/Os

VC-4 matrix

ODU matrix

4x10GbEth 10GbEth

16 x GbEth GbEth

16xSTM1/4

(SFP)

OTUk b&wG709 NNI

CBR

• 2.48Gb

• 9.95Gb

• 39.8Gb

G709 UNI

OTUk ColG709 NNI

4x10G Link

4 x STM64

16 x STM16(SFP)

USR for low-cost

intra-rack

connections

VC3/VC12 matrix

L2 matrixTransparent

card

4x2.5Gb & 2x10Gb

ODU matrix

Lambda 2.5Gb

Lambda 10Gb

Page 15: 1678 Metro Core Connect

1678 Metro Core Connect page - 15All rights reserved © 2002, Alcatel

1678 Metro Core Connect

Multi Ring

Terminal

Add/Drop or

Terminal

Multiplexer

Multiple

> 2F 10G ADM

> 4F 10G ADM

> 2F 40G ADM

> 4F 40G ADM

> Multi Ring Terminal

Cooling subsystem

Po

we

r

Po

we

r

Cooling subsystem

1678 MCC shelf

64

0G

b s

wit

ch

& C

loc

k (

p)

64

0G

b s

wit

ch

& C

loc

k (

w)

2.5

G R

x/T

x (

16

x p

ort

)

1G

BE

Rx/T

x (

16

x p

ort

)

10

GB

E R

x/T

x (

4x

po

rt)

15

5M

Rx/T

x (

16

x p

ort

)

62

2M

Rx/T

x (

16

x p

ort

)E

qu

iSe

rvic

eE

qu

iCo

ng

i

10

G R

x/T

x(2

/1x

po

rt)

10

G R

x/T

x(4

x p

ort

)

common parts

ports

Page 16: 1678 Metro Core Connect

1678 Metro Core Connect page - 16All rights reserved © 2002, Alcatel

1678 MCC – Shelf view

~600m

m

21” (96TE)

Single port slot capacity of 256

STM-1 eq. that can host

• 4 x STM64

• 2/1 x STM64

• 16/8/4 x STM16

• 16 x STM4/1

• 16/8/4 x GbEth

• 4/2 x 10GbEth

~465m

m

Cooling subsystem

Cooling subsystemE

qu

i-S

erg

i

MA

TR

IX 4

096 (

Copy

A)

MA

TR

IX 4

096 (

Copy

B)

Po

we

r

Eq

ui-

Con

gi

Po

we

r

Three shelves per 300mm rack deep

Back-to-back arrangement allowed

Page 17: 1678 Metro Core Connect

1678 Metro Core Connect page - 17All rights reserved © 2002, Alcatel

1678 MCC – Rack view

Three shelves per rack 300mm deep

Back-to-back 300mm rack

arrangement

Up to 384 x STM64 ifs (3.8Tb/s)in 600x600mm footprint

FAN

1678 MCC

FAN

FAN

1678 MCC

FAN

FAN

1678 MCC

FAN

600 mm

600 mm

2200 m

m

Page 18: 1678 Metro Core Connect

1678 Metro Core Connect page - 18All rights reserved © 2002, Alcatel

I/O interface - density figures

Number of interfaces per card / shelf / rack

Page 19: 1678 Metro Core Connect

1678 Metro Core Connect page - 19All rights reserved © 2002, Alcatel

Plug-in optics – mix & match concept

I-16.1 SFP

S-16.1 SFP

L-16.1 SFP

16xSTM16 port

S-1.1 SFP

L-1.1 SFP

16xSTM1 / STM4 port

S-4.2 SFP

L-1.2 SFP

Page 20: 1678 Metro Core Connect

1678 Metro Core Connect page - 20All rights reserved © 2002, Alcatel

X-OADM application

> HW architecture compatible with X-OADM applications (G.709 standard)

> Same hw matrix card can cross connect transparently SDH and ODU-k payloads

> Dedicated UNI/NNI port cards guarantee the transparency both with respect to frequency and frame format of the received signals

Cooling subsystem

Equic

o +

Congi

Serv

ice +

Congi

MA

TR

IX 4

096 (

Copy A

)

MA

TR

IX 4

096 (

Copy B

)

32 x NN/UNI ifs

at 10.7/9.95G

Lin

e W

DM

10

G

TP

D

10

G

TP

D1

0G

TP

D

10

G

TP

D

16x10G NNI

b&w ifs

16x10G NNI

b&w ifs

Master shelf providing

64x64 10G matrix

Page 21: 1678 Metro Core Connect

1678 Metro Core Connect page - 21All rights reserved © 2002, Alcatel

Configuration examples

1) HO multi–Ring application: n stacked 2F or 4F rings @ STM-256/64/16 level with drop @ STM-16/4/1 level

2) Compact cross–connect application:

1678 MCC alone

“cluster” made of several OMSNs (1678SM, 1660SM etc...) and a 1678 MCC up to 4K cross–connect with HO/LO interfaces

Page 22: 1678 Metro Core Connect

1678 Metro Core Connect page - 22All rights reserved © 2002, Alcatel

Example: Multi-Ring application

Cooling subsystem

Equic

o +

Congi

Serv

ice +

Congi

MA

TR

IX 4

096 (

Copy A

)

MA

TR

IX 4

096 (

Copy B

)

Cooling subsystem

Node configuration: 8xSTM-64, 16xSTM-16, 32xSTM-4, 64xSTM-1

7 traffic slots free

available for other

services

two 4xSTM-64

ports (8 interfaces)

one 16xSTM-16

ports (16 interfaces) two 16xSTM-4

ports (32 interfaces)

four 16xSTM-1

ports (64 interfaces)

Page 23: 1678 Metro Core Connect

1678 Metro Core Connect page - 23All rights reserved © 2002, Alcatel

Example: Compact DCS application

Traffic ports:

STM-256 10GE

STM-64 GE

STM-16

STM-4/1o

Traffic ports:

STM-1e/o

GE

Traffic ports:

STM-1e

34/45Mb

Eth 10/100

Traffic ports:

2Mb

To WDM links

STM-64 links

STM-16 links

STM-16 links

1670SM

1660SM 1662SM

Page 24: 1678 Metro Core Connect

1678 Metro Core Connect page - 24All rights reserved © 2002, Alcatel

1678 MCC - Key elements

> Extreme density (3.8Tb capacity in one rack)

> Flexibility

• from 1024xSTM1eq. to 4096xSTM1eq. using same box

• plug-in optics

• share multiple optical types in same card

> Traditional (Multi)Ring application

> Mesh network GMPLS based

> GbE and 10GbE with GFP Rate Adaptation and LCAS support

> SDH and Lambda switch with the same hw matrix

> Optimized intra-rack interconnections

> G.709 i/f management

> Integrated data functionalities

> Clear channel transparent transport in SDH network

Page 25: 1678 Metro Core Connect

1678 Metro Core Connect page - 25All rights reserved © 2002, Alcatel

Thank you !