Bay Control IED REC 670
Gunnar Stranne
Rio de JaneiroApril 23-25, 2006
2
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Bay Control IED REC 670
� Introduction
� Control Capabilities
� User-friendliness
� Openness and Flexibility
� Reliable Operation
� Complementary Functionality
� Summary
3
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Control Capabilities
� Extensive application opportunities for any type of
� switchgear
� switchgear arrangement
REC 670 increases personnel safety and secure operation in all type of control applications in any substation
4
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Introduction – Main Control Features
� Local and Remote (Station/SCADA)
control
� Control functionality for 8, 15 or up to 30
apparatus in up to 6 bays
� For all voltage levels and all busbar
arrangements
� Pre-defined interlocking modules for
single, double and 1 1/2 circuit breaker
arrangements
� Reservation function to prevent
simultaneous operations
5
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
� Tap changer voltage control
� Autoreclosing – single – two - three-phase
� Synchro- and energizing-check function
� Measuring functions - U, I, P, Q, f and cos phi
� Metering via pulse inputs
� mA inputs for external transducers
� Protection functions e.g. breaker failure
protection for a 1 1/2 circuit breaker diameter
� Extensive configuration possibilities and
expandable hardware
Additional features and functions
6
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Local HMI - Human Machine Interface
� Large size HMI� Easy push-button operation –
select before operate� Local remote selection� 15 LEDs freely programmable
� Flashing or permanent light� Signal following� Latched mode
� Single line diagram for control and supervision of up to 30 apparatus
� Settings including authorization handling
� Disturbance information� Self supervision – status LED´s� Standard RJ45 connector to PC
with toolbox (with indication of communication.
7
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
REC670
REC670 REC
670
Single circuit breaker Double circuit breaker 1½ circuit breaker
1U
1U
3U
3I
1U
1U
3U
3I3I
1U
1U
3U
3I
3I
3U
Configuration alternatives
3I
8
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
� Control of several bays
� Complete measurements via up to 24 CTs and PTs
� Cost-efficient solutions for substations especially at lower voltage levels
Control of Several Bays with one REC 670
WA1WA2
QB1 QB2
QA1
QB9
Bay 1
QB1 QB2
QA1
QB9
Bay 2
QB1 QB2
QA1
QB9
Bay 3
9
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Secure Bay and Station Wide Interlocking
� Interlocking with GOOSE is fast & cost-efficient
� Prevents simultaneous operation of disconnectors and earthing switches
� Ensures correct interlocking during operation
Disc QB1 and QB2 closed
WA1 not earthedWA2 not earthedWA1 and WA2 interconn
Disc QB1 and QB2 closed
WA1 not earthedWA2 not earthedWA1 and WA2 interconn
. . . . .
Station bus
QB1
WA1
WA2
Bay 1 Bay n Bus couplerWA1 unearthedWA1 unearthed
WA1 and WA2 interconn
WA1 and WA2 interconnin other bay
QB2
QA1
QB9
QB1 QB2
QA1
QB9
QB2QB1
QA1
QC1 QC2
10
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Optimized Maintenance and Safe Operation
� Switching operations counter
� Automatic sequence control
� Supervision of limits for measurements
WA1WA2
QB1 QB2
QA1
QB9
Bay 1
11
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
REC 670 IEDs are Easy to Handle
� Ready-to-use control IEDs for different
applications
� Easy interlocking engineering for highest
security and availability
� Local control and fast visualization on
HMI
� Access authorization handling
� Local HMI language support
Increased design quality by ready to use control!
12
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
REC 670 Provides Openness and Flexibility
� REC 670 handles your specific requirements
� REC 670 can be easily integrated in any IEC 61850 compliant control system
� REC 670 interoperates with other IEC 61850 compliant IEDs
Instead of modifying the process, let
REC 670 adapt to it
13
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
REC 670 Improves the Operational Reliability� Output supervision ensures high
security against unwanted operation
� “Select before operate” principle
� Protection technology � REC 670 runs on the same HW platform
as the protection IEDs
� REC 670 utilizes common application functions with the protection IEDs
� Unique reservation method for interlocking information
REC 670 prevents operational mistakes and
reduces outage time
eller
14
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Always Correct Interlocking Information
- Using our unique reservation method
Station bus
Station HMI
GW
CloseDisconnector
OpenBreaker
Control center
15
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Bay Control IED REC 670� REC 670 increases personnel safety and secure
operation in all type of control applications in any substation
� REC 670 increases productivity and quality from design to operation and maintenance of your installation
� REC 670 adapts to your process
� REC 670 prevents operational mistakes and reduces outage time
� REC 670 enables significant savings in configuration, setting, erection, commissioning and maintenance cost as well as in space requirements
REC 670 IEDs give you the power to be in full control of your assets – a major leap in grid reliability
16
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Apparatus Control Features
� Operation of primary apparatuses
� Select-before-operate principle to give high security
� Selection and reservation function to prevent simultaneous operation
� Selection and supervision of operator place
� Command supervision
� Block/deblock of operation
� Block/deblock of updating of position indications
� Substitution of position indications
� Overriding of interlocking functions
� Overriding of synchrocheck
� Pole discordance supervision
� Operation counter
17
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Control functions
� Apparatus control for single bay,max 8 app. (1 CB) incl. interlocking 1
� Apparatus control for single bay,max 15 app. (2 CBs) incl. interlocking 1
� Apparatus control for 6 bays,max 30 app. (6 CBs) incl. interlocking 1
� Synchrocheck and energizing check,single, double or 1 1/2 circuit breaker 6
� Autorecloser for 1-, 2-, and/or 3-phase,single, double or 1 1/2 circuit breaker 6
Max no. of instances
18
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Apparatus Control ApplicationControl of primary apparatuses in a substation
Station HSI
IED HMI
19
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Apparatus Control Operator workplacesStation HSI
Gateway
Control Center
ApparatusControl
REC670
I/O
IEC 61850-8-1
breakersdisconnectors
earthing switches
ApparatusControl
REL670
I/O
Remote
Station
Local Alternatives
20
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SXCBRSCSWIQCBAY
SCILO
SXCBRSXCBR
SCSWI
SCILO
SXSWI
-QA1
-QB1
-QB9
Apparatus Control Function blocks
21
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
� Disconnectors shall not be opened or closed on-load
� Earthing switches shall not be closed onto voltage
� CB:s shall not be closed when surrounding disconnectors are in intermediate positions
� CB opening is only interlocked at a bus-coupler bay, if a busbar transfer is in progress
Basic principles - Interlocking
Installed to prevent maloperationsof disconnectors and earthing switches
22
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Data to be sent to other IEDs are defined in an engineering tool(a module in PCM600)
IEC 61850-8-1
GOOSE
IntlReceiveGR01-
BLOCKINSTNAME
RESREQ
RESRENAMRESGRANT
RESGRNAMAPP1NAMEAPP2NAME
APP15NAM
APP1_OPAPP1_CLAPP1VALAPP2_OPAPP2_CLAPP2VAL
APP15_OPAPP15_CLAPP15VALDATA_VALCOM_VAL
� An IED sends information by multicasting
� Only IEDs which are subscribers receive this message
Horizontal communication GOOSE
Generic Object Oriented Substation Event
23
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Interlockingmodule
Interlockingmodules inother bays
Apparatus controlmodules
SCSWI SXSWISCILO
Apparatus controlmodules
Apparatus controlmodules
Interlocking module on bay level
SCSWI SXCBRSCILO
SCSWI SXSWISCILO
Interlocking
24
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Interlocking modules
Function block ABC_LINE� Line bay in arrangements
with single, double, and bypass busbars
Function block ABC_BC� Bus coupler in arrangements
with single, double, and bypass busbars
QB1 QB2
QC1
QA1
QC2
QB9
QC9
WA1 (A)
WA2 (B)
WA7 (C)
QB7
QB1 QB2
QC1
QA1
WA1 (A)
WA2 (B)
WA7 (C)
QB7QB20
QC2
25
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Interlocking modules
Function block AB_TRAFO� Transformer bay in
arrangements with single and double busbar
QC
Function block BB_ES� Busbar earthing switch on
any busbar part
QB1 QB2QC1
QA1
QC2
WA1 (A)
WA2 (B)
QA2
QC3
T
QC4
QB4QB3
QA2 and QC4 are notused in this interlocking
AB_TRAFO
26
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Interlocking modules
Function block A1A2_BS� Bus section coupler between bus
sections A1 and A2
Function block A1A2_DC� Bus section disconnector between
bus sections A1 and A2
QA1
WA1 (A1)
QB2
QC4
QB1
QC3
WA2 (A2)
WA1 (A1) WA2 (A2)QB
27
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Interlocking modules
Function blocks
DB_BUS_A, DB_BUS_B� Bus links of a double
breaker bay
DB_LINE� Line connection of a
double breaker bay
WA1 (A)
WA2 (B)
QB1QC1
QA1
QC2
QC9
QB61
QB9
QB2QC4
QA2
QC5
QC3
QB62
DB_BUS_B
DB_LINE
DB_BUS_A
28
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Interlocking modules
Function blocks
BH_LINE_A, BH_LINE_B� Line connections of a
breaker and a half diameter
BH_CONN� Connection between two
lines of a breaker and a half diameter
WA1 (A)
WA2 (B)
QB1QC1
QA1
QC2
QC9
QB6
QB9
QB2QC1
QA1
QC2
QC3
QB6
QC3
QB62QB61 QA1
QC1 QC2
QC9
QB9
BH_LINE_A BH_LINE_B
BH_CONN
29
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Reservation
The purpose of the Reservation method is:
� To prevent simultaneous operation (manual operation)
� To ensure that interlocking information is correct at the time of operation
30
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Reservation
SCSWI
SELECTEDRES_EXT
REC670REC670
≥1Other SCWI inthe bay
Station bus. . .
SPGGIOIN
RESGRANT
IntlReceive
. . .
. . .
RESGRANT
IntlReceive
Simplified configuration over station bus
Provides high availability
31
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
The configuration with external wiring
SCSWI
SELECTEDRES_EXT
+
REC670
BI BO
REC670
BI BO
≥1Other SCWI in the bay
Reservation
32
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Event handling
PHPIOCIOC1-
BLOCKIDSMPL1IDSMPL2IDSMPL3
TRIPTRL1TRL2TRL3
SPGGIO
SP01-
IN& ≥1
&
SCSWICS01-
BLOCKPSTOL_SELL_OPENL_CLOSEAU_OPENAU_CLOSEBL_CMDRES_GRTRES_EXTSY_INPROSYNC_OKEN_OPENEN_CLOSEXPOS1XPOS2XPOS3
EXE_OPEXE_CL
SELECTEDRES_RQ
START_SYPOSITIONOPENPOS
CLOSEPOSPOLEDISCL_CAUSE
XOUT
Op.generalOp.phsAOp.phsBOp.phsC
Pos.stValPos.qPos.tPos.stSeld
stVal, q, tIE
C 6
1850
-8-1
� Event handling for IEC 61850 is included in the function and ”hidden”for the user.
REx670
33
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Measurements AC quantities
For each value:.mag (magnitude
of reported value)
.range (normal|high|low|high-high|low-low)
IEC
618
50-8
-1
PQSI
Uf
cos φ
CVMMXU
SVRx-
IL1IL2IL33I0IzsIns
CMMXU
CPx-
UL1L2UL2L3UL3L1
3U0UzsUns
VMMXU
VPx-
RANGE_XP
XPx-
HIGHHIGHHIGH
NORMALLOW
LOWLOWAIM Preproc
AIM Preproc
AIM Preproc
REx670
34
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Measurements DC quantities (mA)
IEC
618
50-8
-1
RANGE
MVGGIO
MVx-
CH1CH2CH3CH4CH5CH6
MIM
MIx-
RANGE_XP
XPx-
HIGHHIGHHIGH
NORMALLOW
LOWLOW
IN
For each channel:
.mag (magnitude of reported value)
.range (normal|high|low |high-high|low-low)
mA input module (MIM)
REx670
35
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Synchrocheck function
BLOCK
U-Line U-Bus
SYNC
Line referencevoltageFuse fail
U-Bus
Energizing checkHigh voltage U> 50-120% of UbLow voltage U< 10- 80% of UbOperate time 80 ms (typical)
Paralleling (Synchronism) CheckFrequency difference ∆f < 3-1000 mHzVoltage difference ∆U < 2 - 50 % of UbPhase difference ∆φ < 5 - 90o
Operate time 80 ms (typical)
Accuracy of frequency measurement about 0,5 mHz!
∆φ
∆U
36
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Integrated Functionality - Cost Savings
� Less cabling and no interposing relays needed
� Complete control IED including voltage control
REC 670 enables significant savings in configuration, setting, erection, commissioning and maintenance cost as well as in space requirements
37
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Integrated Functionality - Cost Savings
� Example;Only one REC 670 is needed for control of all apparatuses in one entire diameter in 1½ breaker arrangement including breaker failure protection for all breakers
� Control and back-up functions in one device� Synchrocheck and energizing
check
� Autorecloser
38
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Introducing the IED670 in Substation Automation
Designed to
communicate
39
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with IEC 61850
IEC 61850-8-1
CC
TCP/IP
Station HSI Gateway
40
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with double IEC 61850 networks
IEC 61850-8-1
IEC 61850-8-1
CC
TCP/IP
GatewayStation HSI
41
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with two networks – IEC 61850 and TCP/IP
IEC 61850-8-1
Ethernet
CC
TCP/IP
GatewayStation HSI
42
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with IEC 61850
KIOSK 1 KIOSK 2 KIOSK 3
Station HSIBase System
EngineeringWorkstation
SMS
Gateway
Printer
CC
43
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with IEC 61850
KIOSK 1 KIOSK 2 KIOSK 3
EngineeringWorkstation
SMS
Gateway
Printer
CC
44
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with double IEC 61850 local networks
KIOSK 1 KIOSK 2
CC
KIOSK 3
Printer
EngineeringWorkstation
SMS
Station HSIBase System
Station HSIHSB
Gateway
45
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with LON
REx 5xxREx 5xxREx 5xx
Station HSI CC
Star coupler
LON
RER 111
Gateway
TCP/IP
46
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with LON
REx 5xxREx 5xxREx 5xx
CC
Star couplerLON
RER 111
Gateway
47
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with IEC 60870-5-103
REx 5xxREx 5xxREx 5xx
CC
Starcoupler
IEC 60870-5-103
RER 125
Gateway
TCP/IP
Fiber opticTransceivere.g Westermo MD-62A
Station HSI
48
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SA system with IEC 60870-5-103
REx 5xxREx 5xxREx 5xx
CC
Starcoupler
IEC 60870-5-103
RER 125
Gateway
Fiber opticTransceivere.g Westermo MD-62A
49
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
SMS system with SPA
SPA
Fiber optictransceiver
REx 5xxREx 5xxREx 5xx
Local SMS workplace with CAP 540 and PCM 600.
50
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Summary REC670
� LCD panel with single line diagram for control and supervision
� Standard station communication with IEC 61850-8-1
� Simplified Substation Automation engineering with ready to use apparatus control modules following IEC 61850
� Improved performance
� More analog inputs with more flexibility
� Multiple protection functions
� Ready-to-use product configurations
� Authorization handling
51
©A
BB
Pow
er T
echn
olog
ies
AB
, 20
05
2006-04-20 Gunnar Stranne
Summary REC670
� REC 670 increases personnel safety and enables secure operation in all types of control applications in any substation
� REC 670 increases productivity and quality from design to operation and maintenance
� REC 670 is adaptable to the operating environment
� REC 670 prevents operational mistakes and permits a reduction of the outage times
� REC 670 enables significant savings in configuration, setting, erection, commissioning and maintenance cost as well as in needed space requirements
REC 670 IEDs provides full control and more – a major leap in grid reliability