126147 cavius nz 10 year instruction manual rev...

1
Cavius DIY smoke detector Model 2002-006 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE USE AND RETAIN FOR FUTURE USE! Cavius smoke alarm is a smoke detector for private homes, camping trailers and caravan installations. It is not recommended for boats. Technical information: Type of alarm: Cavius smoke alarm is a photo electric smoke alarm. Alarm signal: Fire alarm activation is indicated by a min. 85 dB at 3 meter. Battery: Powered by a non-placeable 3v CR123 A DE- SAY Lithium battery with 10-year life (included). Low battery indicator: A short acoustic “beep” will - tery is near its end of life. In this stage it will continue for minimum 30 days. smoke alarm is not active unless it is inserted in the mounting base. mounting base (Allow a few seconds before testing). Placement: smoke alarm should be minimum 50 cm from the wall, maximum distance between smoke alarms of 10 me- tres. Sound Test button Mounting base Smoke alarm signal: and acoustic signal. In the passive state, the LED will emit a sweeping sound pattern designed to alert oc- cupants. Hush function: In case of unintentional alarm condi- automatically resume its normal function. Maintenance: cleaned once per month, and it can be wiped with a wet cloth (Do not open the alarm). Test the smoke alarm once per Month by pushing the tone. and bedrooms as minimum. stairways. - Smoke alarms in each room such as bed rooms and living rooms. Additional smoke alarms increase the security. Installation of smoke alarm: 1. Detach the smoke alarm from the mounting base by twisting counter clockwise. Use the mounting base ring to mark the screw holes on the ceiling. Use the enclosed screws and plugs for installing the mounting base. the test button on the side and get a loud sound. Info: due to important information regarding the product. - In dusty rooms - At the top of high pointed ceilings or in ceiling cor- ners or within 50cm of a wall. - In rooms where the temperature goes outside +4º to 38ºC or above 90% relative humidity non condensing. and smoke could occur. Place the smoke alarm where it is reachable in order to test the battery and maintenance. If the smoke alarm activates without vis- ible cause, then possible cause could be: Dust particles in the smoke chamber which can be re- moved by heavy blow to the mesh. High humidity condensing which can be resolved by drying the smoke alarm. If the smoke alarm does not work when the test button is pushed the probably cause is a faulty battery, and the smoke alarm must be replaced. Other information: Do not paint the smoke alarm. Note the local country regulations regarding installa- tion of mains powered smoke alarms in new buildings. Disposal: For battery and product, please dispose properly at end of life. Manufactured by Aps Julsøvej 16 - DK8600 Silkeborg www.cavius.com - [email protected] Manufactured in P.R.C. Type of mounting Ceiling only Main power supply Internal power source (battery included) Battery duration 10 years Interconnectable device Yes No Suitable for installation in mobile home Yes No Connection to external auxiliary devices Yes No Radio link Yes No Individual alarm indicator Yes No Alarm silence facility (10 min) Yes No No radioactivity infrared technology Yes No Accessibility option Yes No Mark up screw holes with a pen Minimum 50cm from wall Use the enclosed screws and plugs for installation - formity to the European directives that are applicable EN14604. 126147 rev 6 Distributor information: 2G Ashley Place, Papamoa | Bay Of Plenty | 3118 P.O Box 11241 Palm Beach Plaza, Papamoa . Bay Of Plenty . 3118 . New Zealand Hotline: 0800 766533 or 07 542 2191 | W. www.cavius.co.nz Smoke Alarm DoP no.: CAV10-2002-006 0333 EN14604:2005/AC:2008 14 0333-CPR-292058-2

Upload: others

Post on 22-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 126147 CAVIUS NZ 10 year instruction manual rev 5s3.hubsrv.com.s3.amazonaws.com/.../CAVIUS-NZ-10Y-SMOKE-MAN… · Cavius smoke alarm is a smoke detector for private homes, camping

Cavius DIY smoke detector Model 2002-006

Manufactured by CAVIUSPLEASE READ THE USER GUIDE

CAREFULLY BEFORE USE AND RETAIN FOR FUTURE USE!

Cavius smoke alarm is a smoke detector for private homes, camping trailers and caravan installations. It is not recommended for boats.

Technical information: Type of alarm: Cavius smoke alarm is a photo electric smoke alarm.

Alarm signal: Fire alarm activation is indicated by a

min. 85 dB at 3 meter.

Battery: Powered by a non-placeable 3v CR123 A DE-SAY Lithium battery with 10-year life (included).

Low battery indicator: A short acoustic “beep” will -

tery is near its end of life. In this stage it will continue for minimum 30 days.

smoke alarm is not active unless it is inserted in the mounting base.

mounting base (Allow a few seconds before testing).

Placement:smoke alarm should be minimum 50 cm from the wall,

maximum distance between smoke alarms of 10 me-tres.

Sound

Test button

Mounting base

Smoke alarm signal: and acoustic signal. In the passive state, the LED will

emit a sweeping sound pattern designed to alert oc-cupants.

Hush function: In case of unintentional alarm condi-

automatically resume its normal function.

Maintenance:cleaned once per month, and it can be wiped with a wet cloth (Do not open the alarm).Test the smoke alarm once per Month by pushing the

tone.

and bedrooms as minimum.

stairways.- Smoke alarms in each room such as bed rooms and living rooms.Additional smoke alarms increase the security.

Installation of smoke alarm:1. Detach the smoke alarm from the mounting base by twisting counter clockwise. Use the mounting base ring to mark the screw holes on the ceiling. Use the enclosed screws and plugs for installing the mounting base.

the test button on the side and get a loud sound.Info:due to important information regarding the product.

- In dusty rooms- At the top of high pointed ceilings or in ceiling cor-ners or within 50cm of a wall.- In rooms where the temperature goes outside +4º to 38ºC or above 90% relative humidity non condensing.

and smoke could occur.Place the smoke alarm where it is reachable in order to test the battery and maintenance.

If the smoke alarm activates without vis-ible cause, then possible cause could be: Dust particles in the smoke chamber which can be re-moved by heavy blow to the mesh.High humidity condensing which can be resolved by drying the smoke alarm.If the smoke alarm does not work when the test button is pushed the probably cause is a faulty battery, and the smoke alarm must be replaced.

Other information:Do not paint the smoke alarm.Note the local country regulations regarding installa-tion of mains powered smoke alarms in new buildings.Disposal: For battery and product, please dispose properly at end of life.

Manufactured by Aps Julsøvej 16 - DK8600 Silkeborgwww.cavius.com - [email protected] in P.R.C.

Type of mounting Ceiling only

Main power supply Internal power source (battery included)

Battery duration 10 years

Interconnectable device Yes NoSuitable for installation in mobile home Yes No

Connection to external auxiliary devices Yes NoRadio link Yes No

Individual alarm indicator Yes No

Alarm silence facility (10 min) Yes No

No radioactivity infrared technology Yes No

Accessibility option Yes No

Mark up screw holes with a pen

Minimum 50cm from wall

Use the enclosed screws and plugs for installation

-formity to the European directives that are applicable

EN14604.

126147 rev 6

Distributor information:2G Ashley Place, Papamoa | Bay Of Plenty | 3118P.O Box 11241 Palm Beach Plaza, Papamoa . Bay Of Plenty . 3118 . New Zealand

Hotline: 0800 766533 or 07 542 2191 | W. www.cavius.co.nz

Smoke AlarmDoP no.: CAV10-2002-006

0333EN14604:2005/AC:2008

140333-CPR-292058-2