The benefits of our Zebra luminaires DW Windsor Zebra luminaires are available in a variety of styles so they can be matched to the luminaires used elsewhere on the scheme, furthermore we can supply every element required for pedestrian crossing lighting; from column to Belisa beacon; minimise installation cost and street clutter by positioning the Zebra luminaire on the same column as the Belisha globe. These guidance parameters (explored in more depth in the ILE publication TR12) mean that the ideal pedestrian crossing luminaire will distribute most of its light in a concentrated pattern forward of the luminaire in a high enough beam spread to ensure that the complete height of the pedestrian is illuminated. DW Windsor Zebra Floods offer this ideal distribution and are therefore eminently suitable for this application. Reference material Please refer to the following publications for the full requirements of lighting pedestrian crossings BS EN 13201-2: 2003 Road Lighting Part 2: Performance requirements, Annex B BS 5489-1: 2003 Code of practice for the design of road lighting – Part 1: Lighting of roads and public amenity areas Paragraphs 11.5, E.2.4, E.3.3 CEN/TR13201-1:2004 Paragraph 5.3.9 ILE (Institution of Lighting Engineers) Technical Report Number 12 “Lighting of Pedestrian Crossings” Lighting pedestrian crossings There are three principle issues to consider when illuminating a Zebra crossing. • Making the crossing itself highly visible and distinguishable from the surrounding road. • Visibility of pedestrians at the crossing and through visibility (to ensure motorists are also aware of pedestrian activity beyond or in front of the crossing). • Minimising glare to drivers. In order to achieve these objectives an appropriate form of supplementary lighting is required. To ensure that the approaching motorist clearly sees the place where pedestrians are to cross, the lighting must generate a defined luminous patch of light across the crossing carpet, with clearly delineated edges. Consider also the area beyond the crossing from the driver’s perspective.The approaches to the crossing marked by zig zag lines – the controlled area – and the adjacent footways should also be adequately lit; this may be to the appropriate CE or S class. Where the road is lit to an ME class then the pavements by the controlled area should be lit to the appropriate S class. A low mounting height of no more than 4 metres and often around 2.5 metres is usually most suitable to create this delineated carpet. While a different lamp colour from the surrounding road lighting is effective in helping highlight the carpet – for example white light (metal halide) on the crossing in a yellow light (high- pressure sodium) road installation. Luminaires need to be as glare free as possible to ensure maximum through visibility through the crossing area – remember pedestrians will often try to cross short of the crossing itself. Flat glass luminaires are therefore best. Finally the light distribution from the luminaire itself needs to ensure high levels of vertical illuminance onto the crossing pedestrian to ensure that they are visible to approaching motorists. Because humans are three dimensional rather than two dimensional, this vertical illumination does not need to fall exclusively onto the side of the pedestrian facing the traffic. In falling onto the curved surface facing the luminaire the pedestrian will still be rendered visible to the motorist). Ely Zebra Long Crendon, Buckinghamshire 37 dwwindsor.co.uk [email protected] Road class (see also BS 5489-1:2003 table B1) CE1 CE2 S1 S2 S3 S4 Carpet average (with 60% uniformity) [ Eave ] in lux 105 70 52.5 35 26.25 17.5 Centre and kerb edge grid minimum vertical illuminance [ Evmin ] in lux 60 40 30 20 15 10 Rear of waiting area grid minimum vertical illuminance [ Evmin ] in lux 45 30 22.5 15 11.25 7.5 Target lighting values from TR12 NB. This table is not a substitute to a full copy of TR12 which can be purchased from the ILE. Windsor Zebra West Wycombe, Buckinghamshire how-to guides

Upload: cosmin-mihalte

Post on 28-Nov-2015

77 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: 1236946741Lighting Pedestrian Crossings

The benefits of our Zebraluminaires

DW Windsor Zebra luminaires are available ina variety of styles so they can be matched tothe luminaires used elsewhere on the scheme,furthermore we can supply every elementrequired for pedestrian crossing lighting; fromcolumn to Belisa beacon; minimise installationcost and street clutter by positioning the Zebraluminaire on the same column as the Belishaglobe.

These guidance parameters (explored in moredepth in the ILE publication TR12) mean thatthe ideal pedestrian crossing luminaire willdistribute most of its light in a concentratedpattern forward of the luminaire in a highenough beam spread to ensure that thecomplete height of the pedestrian isilluminated.

DW Windsor Zebra Floods offer this idealdistribution and are therefore eminentlysuitable for this application.

Reference material

Please refer to the following publications for the full requirements of lighting pedestrian crossings

BS EN 13201-2: 2003 Road Lighting Part 2:Performance requirements, Annex B

BS 5489-1: 2003 Code of practice for thedesign of road lighting – Part 1: Lighting ofroads and public amenity areasParagraphs 11.5, E.2.4, E.3.3

CEN/TR13201-1:2004 Paragraph 5.3.9

ILE (Institution of Lighting Engineers) Technical Report Number 12 “Lighting ofPedestrian Crossings”

Lighting pedestriancrossingsThere are three principle issues to consider

when illuminating a Zebra crossing.

• Making the crossing itself highly visible anddistinguishable from the surrounding road.

• Visibility of pedestrians at the crossing andthrough visibility (to ensure motorists arealso aware of pedestrian activity beyond orin front of the crossing).

• Minimising glare to drivers.

In order to achieve these objectives an appropriateform of supplementary lighting is required.

To ensure that the approaching motorist clearlysees the place where pedestrians are to cross,the lighting must generate a defined luminouspatch of light across the crossing carpet, withclearly delineated edges. Consider also thearea beyond the crossing from the driver’sperspective.The approaches to the crossingmarked by zig zag lines – the controlled area –and the adjacent footways should also beadequately lit; this may be to the appropriateCE or S class. Where the road is lit to an MEclass then the pavements by the controlledarea should be lit to the appropriate S class.

A low mounting height of no more than 4 metresand often around 2.5 metres is usually mostsuitable to create this delineated carpet. Whilea different lamp colour from the surroundingroad lighting is effective in helping highlightthe carpet – for example white light (metalhalide) on the crossing in a yellow light (high-pressure sodium) road installation.

Luminaires need to be as glare free as possibleto ensure maximum through visibility throughthe crossing area – remember pedestrians willoften try to cross short of the crossing itself.Flat glass luminaires are therefore best.

Finally the light distribution from the luminaireitself needs to ensure high levels of verticalilluminance onto the crossing pedestrian toensure that they are visible to approachingmotorists. Because humans are three dimensionalrather than two dimensional, this verticalillumination does not need to fall exclusivelyonto the side of the pedestrian facing the traffic.In falling onto the curved surface facing theluminaire the pedestrian will still be renderedvisible to the motorist).

Ely ZebraLong Crendon, Buckinghamshire

[email protected]

Road class (see also BS5489-1:2003 table B1)

CE1

CE2

S1

S2

S3

S4

Carpet average (with 60%uniformity) [ Eave ] in lux

105

70

52.5

35

26.25

17.5

Centre and kerb edge grid minimum verticalilluminance [ Evmin ] in lux

60

40

30

20

15

10

Rear of waiting area grid minimum verticalilluminance [ Evmin ] in lux

45

30

22.5

15

11.25

7.5

Target lighting values from TR12

NB. This table is not a substitute to a full copy of TR12 which can be purchased from the ILE.

Windsor ZebraWest Wycombe, Buckinghamshire

how

-to

guid

es

Page 2: 1236946741Lighting Pedestrian Crossings

Lighting pedestriancrossingsHow to

For a standard two lane carriageway, twoZebra luminaires are required for eachcrossing, positioned on opposite sides of theroad between the oncoming traffic and thecrossing.

We can supply every element required forpedestrian crossing lighting:

Ely ZebraLong Crendon, Buckinghamshire

[email protected]

Complete Zebra service

As part of our standard service we can supplynot just the Zebra luminaires, but all of theindividual elements that make up thecomplete Zebra product package.

This covers everything from the specially-designed luminaire, Belisha beacons withflasher unit and supporting brackets, to fully-painted columns complete with black andwhite bands.

In addition, our applications department canundertake the lighting scheme design for you,so you can be sure your pedestrian crossing islit to meet required standards.

Precise light control

We have introduced a new 'flood' opticalsystem to provide the light control needed forthe localised lighting of pedestrian crossings.The Zebra Flood optic is available in a numberof luminaire styles, so continuity can beachieved with the rest of your lighting scheme.

Luminaire

Column

Belisha beacons with flasher unit and supporting brackets

Painting of black & white bands

Lighting design

1

2

3

4

5

Zebra product ranges

Colada Zebrap 254-255

Monaro Zebrap 80-83

Ely Zebrap 120-121

Windsor Zebrap 146-147

Optima Range Zebrap 86-101

Strand Zebrap 114-119

Iffley Zebrap 126-127

York Range Zebrap 128-143

New universal Zebra Flood Optic is suitable for both one and two-way traffic