120 ap-am imi schirding presentation

16
1 April 2007 Proprietary of IMI Commercial In Confidence XM329 , T 120mm - MP - APAM (Anti-Personnel / Anti-Materiel – Multi Purpose Tank Round) National Defense Industrial Association 42 nd Annual Armament Systems: G&M Systems Charlotte, NC April 23-26, 2007 Israel Military Industries Ltd. (IMI) P.O. Box 1044 Ramat Hasharon 47100, ISRAEL [email protected] Danny Schirding Chief Systems Engineer & Sr. PM Tank Ammunition Directorate

Upload: chicco1234

Post on 03-Jan-2016

66 views

Category:

Documents


12 download

DESCRIPTION

This presentation cover 120/44 antipersonel antimaterial ammunition, IMI madE.

TRANSCRIPT

Page 1: 120 AP-AM IMI Schirding Presentation

1 April 2007Proprietary of IMI Commercial In Confidence

XM329, T 120mm-MP-APAM(Anti-Personnel / Anti-Materiel – Multi Purpose Tank Round)

National Defense Industrial Association42nd Annual Armament Systems: G&M Systems

Charlotte, NCApril 23-26, 2007

Israel Military Industries Ltd. (IMI)P.O. Box 1044Ramat Hasharon 47100, [email protected]

Danny SchirdingChief Systems Engineer & Sr. PM

Tank Ammunition Directorate

Page 2: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 2 Commercial in Confidence

APAM 120MISSION STATEMENT

To provide the best round for Main Battle Tanks (MBTs)

against targets other than tanks:

To incapacitate infantry, especially AT squads (Ambush)

To penetrate bunkers and buildings with maximum

resulting damage

To breach walls, allowing passage of friendly troops

To destroy light armored vehicles (LAV’s)

To deter/destroy helicopters (Self Defense)

To provide rapid and lethal direct fires in support of

assaulting infantry

To be effective in Military Operation in Urban Terrain (MOUT)

Page 3: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 3 Commercial in Confidence

APAM 120 XM329

Multi – Purpose Tank round

Used with all NATO 120 mm smooth-bore guns

Compliant with:

STANAG 4385 & AEP 26

STANAG 4493

STANAG 4369 & AOP 22

STANAG 4157

MIL-STD-810

MIL-STD-1316 & 331

ITOP and others

IDF specifications and requirements

Page 4: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 4 Commercial in Confidence

(*) – Programmable Electronic Fuze System

Electronic Fuze (*)

Projectile

Propelling System

Stub Case

Propellant (M26)

Electric Primer

Combustible Cartridge Case

Tracer

Data Link

Tail

Electronic Base Fuze(*)

6 Warheads

Ejection Charge

Ejection Plate

984 mm

27 Kg

17 Kg

750 mm

900 m/sec

0.3 mil

- 40 ÷ 63 ºc

- 40 ÷ 52 ºc

Cartridge length

Cartridge weight

Projectile weight

Projectile Length

Muzzle velocity

Chamber pressure

Accuracy (SD)

Temperature limit - Storage

Temperature limit - Firing

3,400 bar

APAM 120 Anti-Personnel/Anti-Materiel Round

Page 5: 120 AP-AM IMI Schirding Presentation

APAM 105 / 120mm Date: 2006 5 Commercial in Confidence

APAM 120mm – Warhead

Three independent safety mechanisms

according MIL-STD-1316

centrifugal

set-back (pin)

body caging

Neutralization pin for safety improvement

Twin sliders for redundancy

Reliability of operation > 97% (warhead)

Hazardous duds < 0.1%

Designed for optimal fragmentation

performance and high lethality

Page 6: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 6 Commercial in Confidence

APAM 120 Modes of Operation

1) Ejection of 6 warheads at the set range -Anti - Personnel [AP]

Anti Helicopter [AH]

2) Impact W/Delay [Delay = f (range)]

3) Impact - Super Quick [S.Q.]

4) Air-burst at the set range [unitary warhead]

“Extra” features –Air-Burst functioning as Back-up to Ejection Mode

Grazing functioning

Impact as default set

Page 7: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 7 Commercial in Confidence

FCS (Bi-Directional Date Link)

Round ID –

Type, Muzzle Velocity, Temp.

Talk forward (Data Link to Round in Gun) –

Mode of operation, Range, Power, Continuous Programming up date

Talk-back message (from the Round) -

Data Linked, Errors.

Trigger

APAM 120 Ammunition Data Link/Fuze Setting

Round in Gun

120mm smoothbore NATO gun

Junction Box

Junction Box

1001000 10 1

Inductive Setting -Fuze Setter (in emergency)

Page 8: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 8 Commercial in Confidence

Program Integration Management Chart & Main Milestones

I-MOD: System Integration

FCS & Data LinkElbit

Systems Ltd.

Cartridge &

Data Link

Israel

Military

Industries

Ltd. (IMI)

Reshef

Technologies Ltd.Fuze System

PR

OD

UC

TIO

NIntegration Tests

& CDR

IMI & IDF

Safety

Tests

Approval

Operational

Trials

IDF

Qualification

Tests

IDF

PRR

IMI

Page 9: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 9 Commercial in Confidence

AROFSD

Warhead

Projectile

Integration CDR Qualification Certification

APAM 120Development Program – Main WBS

Serial

Production

Data Link

Primer

FuzeSystem

Page 10: 120 AP-AM IMI Schirding Presentation

APAM 105 / 120mm Date: 2006 10 Commercial in Confidence

Length of beaten area compensates

for inaccurate ranging.

APAM – AP mode on the Battlefield

Page 11: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 11 Commercial in Confidence

APAM 120High Stability at Long Ranges – Excellent Accuracy

Page 12: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 12 Commercial in Confidence

APAM 120Warhead Separation and radial dispersion

1

2

3

Page 13: 120 AP-AM IMI Schirding Presentation

APAM 105 / 120mm Date: 2006 13 Commercial in Confidence

AM MODE (IMPACT)

Projectile will -Penetrate LAV’sPenetrate bunkersBreach walls

High density of lethal fragments inside

Page 14: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 14 Commercial in Confidence

No need to change/modify

the Breech Block

The Data Link current doesn’t pass through the primer igniterMIL-STD 1512 MIL-I-23659CAll Fire>2.1ANo Fire<1.0ASafety: db

Switching

Unit

Base Fuze

Front Fuze

Primer

APAM 120Primer and Ammunition Data Link

Page 15: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 15 Commercial in Confidence

APAM 120Special Firing Box & Data Setting

Used During FSD

Data Link or

Inductive settings

Page 16: 120 AP-AM IMI Schirding Presentation

APAM 120mm Date: 2007 16 Commercial in Confidence

10

5m

m

120mm