1 PV essentials from standards to testing
12 Years experience on PV module testing- testing Services -
TÜV Rheinland Group
C.DreierTÜV Rheinland JapanPhotovoltaicEnergy and Environment TechnologyIndustrial ServicesTel.:+ 81 45 914 [email protected]
W.Vaassen, W.Herrmann, J.Althaus, TÜV Immissionsschutz und Energiesysteme GmbHAm Grauen Stein, 51105 Köln, GermanyTel.:+ 49 221/ 806 2870, Fax + 49 221/806 1350
![Page 2: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/2.jpg)
2 PV essentials from standards to testing
�Facilities
• TÜV Rheinland, Cologne
• TÜV Rheinland Japan, Yokohama
• TÜV Rheinland Shanghai, Shanghai
• TÜV Rheinland North America, Phoenix
• TÜV Rheinland Taiwan, Taipei
![Page 3: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/3.jpg)
3 PV essentials from standards to testing
�Type approval qualification of Photovoltaic-ModulesStandards
EN IEC 61215 (1993): Crystalline silicon terrestrial photovoltaic (PV)
modules – Design qualification and type approval
IEC 61215 (2005): Crystalline silicon terrestrial photovoltaic (PV)
modules – Design qualification and type approval
Edition 2
IEC 61646 (2008): Thin-film terrestrial photovoltaic (PV) modules –
Design qualification and type approval
Edition 2
IEC 61730 (2004): Photovoltaic (PV) module safety qualification
- Part 1: Requirements for construction
- Part 2: Requirements for testing
![Page 4: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/4.jpg)
4 PV essentials from standards to testing
Visual Inspection, Performance, Insulation, Wet leakage
� IEC 61215, Ed. 2 (April 2005) Crystalline silicon terrestrial PV modules - Design qualification and type approval
Preconditioning (5 kWh/m²)
Thermal cycling(200 cycles)
ElectricalParameters
OutdoorTest
Bypass Diode Test
Hot-Spot Test
UV preconditioning
Thermal cycling(50 cycles)
Humidity freezeTest
TerminationsTest
Damp Heat Test
Hail Test
Mech.Load
Visual Inspection, Performance, Insulation, Wet leakage
![Page 5: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/5.jpg)
5 PV essentials from standards to testing
Visual Inspection, Performance, Insulation, Wet leakage
� IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules - Design qualification and type approval
Thermal cycling(200 cycles)
ElectricalParameters
OutdoorTest
Bypass Diode Test
Hot-Spot Test
UV preconditioning
Thermal cycling(50 cycles)
Humidity freezeTest
TerminationsTest
Damp Heat Test
Hail Test
Mech.Load
Visual Inspection, Performance, Insulation, Wet leakage
Light soaking
![Page 6: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/6.jpg)
6 PV essentials from standards to testing
� IEC 61215Pass Criteria
Extract from IEC 61215:
![Page 7: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/7.jpg)
7 PV essentials from standards to testing
�Measurement of modulesSteady state solar simulator
![Page 8: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/8.jpg)
8 PV essentials from standards to testing
�Measurement of modulesFlash type solar simulator (long pulse 800ms) AAA
![Page 9: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/9.jpg)
9 PV essentials from standards to testing
�Measurement of modulesspectral response equipment
![Page 10: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/10.jpg)
10 PV essentials from standards to testing
�Measurement of modulesFlash type solar simulator (3m x 3m surface AAA (<1% uniformity))
![Page 11: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/11.jpg)
11 PV essentials from standards to testing
�Measurement of modulesFlash type solar simulator (3m x 3m surface AAA (<1% uniformity))
![Page 12: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/12.jpg)
12 PV essentials from standards to testing
�Outdoor Test
Outdoor exposure dose:
60 60 kWh/mkWh/m²²NOCT:
![Page 13: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/13.jpg)
13 PV essentials from standards to testing
�Bypass diode thermal testPossible problem in field installation
3,8°C
37,0°C
10
20
30
Active by-pass diode (closed connection box)
24,7°C
84,1°C
40
60
80
Active by-pass diode (connection box with open lid)
![Page 14: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/14.jpg)
14 PV essentials from standards to testing
�Bypass diode thermal testExample of test performance
38,0°C
163,0°C
40
60
80
100
120
140
160
Diode type: 80 SQ 045 Tj max = 175°C
CurrentCurrentCurrentCurrent[A][A][A][A]
Box Temperature[[[[°°°°C]C]C]C]
Junction TemperatureJunction TemperatureJunction TemperatureJunction TemperatureTTTTJJJJ [ [ [ [ °°°°C]C]C]C]
4.88 (ISC) 128.2 135.2
6.1 (1.25*ISC) 144.2 151.2
![Page 15: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/15.jpg)
15 PV essentials from standards to testing
�Hot-Spot endurance testProblem
Cell Voltage
Cell Current
Reverse-Voltage
Module Current
Forward-Voltage
Forward-Voltage
Solar-cellIV-curves
ReducedIrradiationIrradiation
Infraredimages
![Page 16: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/16.jpg)
16 PV essentials from standards to testing
�Hot-Spot endurance testTest failure
182 °C
326 °C
200
250
300
Hot-Spots can produce severe visible defects on module front and rear side (temperatures > 300 °C !)
![Page 17: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/17.jpg)
17 PV essentials from standards to testing
�UV-preconditioning testTÜV test chamber Browning effects of EVA
- Dose UV (280 nm - 400 nm): > 15 kWh/m²
- Dose UV-B (280 nm - 320 nm): =3 to 10 % of total UV
- Module temperature: 60 °C
![Page 18: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/18.jpg)
18 PV essentials from standards to testing
�Climatic-TestsTÜV test facilities
![Page 19: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/19.jpg)
19 PV essentials from standards to testing
�Climatic-TestsThermal cycling test
200 (50) temperature cycles from -40 °C to 85 °C
Edition 2:
Current flow (IMPP ± 2%) through modules (t > 25 °C)
![Page 20: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/20.jpg)
20 PV essentials from standards to testing
�Climatic-TestsHumidity-Freeze test
![Page 21: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/21.jpg)
21 PV essentials from standards to testing
�Climatic-TestsDamp heat test
Test temperature: 85 °C ± 2 °C
Relative Humidity: 85% ± 5%
Test duration: 1000 hours
Module temperature/ °C
Time / h
85
0 500 1000
![Page 22: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/22.jpg)
22 PV essentials from standards to testing
�Climatic-TestsTest failures I: Module delaminations
![Page 23: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/23.jpg)
23 PV essentials from standards to testing
�Climatic-TestsTest failures II: Boxes and connectors
Crumbled junction box
Broken and shrunken plugs
Crumbled junction box
Zinc dust
![Page 24: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/24.jpg)
24 PV essentials from standards to testing
�Climatic-TestsTest failures III: Solar cells
Corrosion of cell interconnector
Cracking of cells
Shifting ofcells
Cell delamination
![Page 25: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/25.jpg)
25 PV essentials from standards to testing
�Climatic-TestsTest failures IV: Other
Browning of string-connector
Shrinking of foil
Come off of the foil
Glass-corrosion
![Page 26: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/26.jpg)
26 PV essentials from standards to testing
�Climatic testsTest failure – IV-curves
Reduction of Fill-Factor due to increasement of series resistance
Power loss of strings due to interrupted interconnects
![Page 27: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/27.jpg)
27 PV essentials from standards to testing
�Climatic testsDamp Heat test, test experience last 5 years
![Page 28: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/28.jpg)
28 PV essentials from standards to testing
�Mechanical load testTest performance
3 load-tension cycles:
2400 Pa, 1 hour
Optional: 5400 Pa
![Page 29: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/29.jpg)
29 PV essentials from standards to testing
�Mechanical load testTest failures
![Page 30: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/30.jpg)
30 PV essentials from standards to testing
�Hail impact testTest performance
Hail impact shots on 10 different locations:
Iceball speed: 23 m/s
Iceball diameter: 2.5 cm
![Page 31: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/31.jpg)
31 PV essentials from standards to testing
�Light soakingTÜV test facilities
![Page 32: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/32.jpg)
32 PV essentials from standards to testing
�Summary Test statistic
Measurement of different PV- module typestest results (last 8 years)
0 20 40 60 80 100
%
All Tests
Passed
Fault
![Page 33: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/33.jpg)
33 PV essentials from standards to testing
�Summary Test statistic of new certification processes
Failure, Module typenot accepted
Certificationwithout anyproblems
Certification with problems(Repeat of tests)
30 %20 %
50 %
![Page 34: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/34.jpg)
34 PV essentials from standards to testing
� Test failuresHow to continue?
• If the test samples fail in several different qualification tests (i. g. damp-heat, thermal-cycling and hot-spot) we have to reject the complete module design!
The manufacturer can then reapply with an improved design.
• If one qualification test is failed, the following procedure applies:
• The failed test sample(s) will be shipped back to the manufacturer for investigation.
• The manufacturer provides us with a detailed failure analysis report:
• What exactly was the reason for the failure?
• What measures will be taken to avoid such failures?
• With this evaluation report at hand, TÜV decides what tests have to be repeated with new test samples.
• If the repetition of the selected tests is passed, TÜV will issue the certificate.
If the test-repetition is failed again, the module design has to be rejected!
![Page 35: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/35.jpg)
35 PV essentials from standards to testing
�SummaryConclusion
• Although PV-modules have reached a sophisticated level of technology, a lot of different test-failures occur in laboratory testing
• Manufacturing a PV-Module that is able to pass all qualification tests is a difficult task. All materials, components and process parameters
have to be chosen carefully.
• Even small design changes can effect the suitability of the module design and therefore may require a retesting program to maintain type
approval certification.
![Page 36: 12 Years experience on PV module testing -testing Services · IEC 61646, Ed. 2 (2008) Thin-film terrestrial PV modules -Design qualification and type approval Thermal cycling (200](https://reader035.vdocuments.site/reader035/viewer/2022081403/60a2705da8529e13ba75a4a8/html5/thumbnails/36.jpg)
36 PV essentials from standards to testing
Thank you for your kind attention