12-128
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
January 2001
Molded Case Circuit Breakers
12
Earth Leakage Circuit ProtectorsVol. 1, Ref. No. [0594]
Table 12-200. K-Frame Earth Leakage Ground Fault Breakers UL 489 and UL 1053
Note: Instruction Leaflet/FRED Number 29C118 or S.A.29A.03.S.E
Table 12-201. Optional K-Frame Line and Load Terminals – Order Separately
1 Package of 3 terminals.2 Package of 4 terminals.
Table 12-202. F-Frame HMCP with Earth Leakage Ground Fault
Table 12-202. F-Frame HMCP with Earth Leakage Ground Fault (Continued)
Table 12-203. J and K-Frame HMCP with Earth Leakage Ground Fault
Amperes 35 kA at 480V AC 65 kA at 480V AC 100 kA at 480V AC
3-Pole 4-Pole 3-Pole 4-Pole 3-Pole 4-Pole
CatalogNumber
PriceU.S. $
CatalogNumber
PriceU.S. $
CatalogNumber
PriceU.S. $
CatalogNumber
PriceU.S. $
CatalogNumber
PriceU.S. $
CatalogNumber
PriceU.S. $
200225250300350400
ELKD3200ELKD3225ELKD3250ELKD3300ELKD3350ELKD3400
4,615.004,615.004,615.004,615.004,615.004,615.00
ELKD4200ELKD4225ELKD4250ELKD4300ELKD4350ELKD4400
6,150.006,150.006,150.006,150.006,150.006,150.00
ELHKD3200ELHKD3225ELHKD3250ELHKD3300ELHKD3350ELHKD3400
7,190.007,190.007,190.007,190.007,190.007,190.00
ELHKD4200ELHKD4225ELHKD4250ELHKD4300ELHKD4350ELHKD4400
8,330.008,330.008,330.008,330.008,330.008,330.00
ELKDC3200ELKDC3225ELKDC3250ELKDC3300ELKDC3350ELKDC3400
7,330.007,330.007,330.007,330.007,330.007,330.00
ELKDC4200ELKDC4225ELKDC4250ELKDC4300ELKDC4350ELKDC4400
10,290.0010,290.0010,290.0010,290.0010,290.0010,290.00
Wire Type
(Number) Rangeof Conductors
TerminalMaterial
CatalogNumber
PriceU.S. $
Cu/AlCu/Al
(2) 250 kcmil(1) 500 kcmil
AluminumAluminum
3TA401K 1 66.00
Cu/AlCu/Al
(2) 250 kcmil(1) 500 kcmil
AluminumAluminum
4TA401K 2 76.00
CuCuCu
(1) 3 – 350 kcmil(1) 3 – 350 kcmil(1) 250 – 500 kcmil
CopperCopperCopper
T300KT300KT350K
29.5029.5029.50
CuCuCu
(1) 250 – 500 kcmil(1) 3/0 – 250 kcmil(1) 3/0 – 250 kcmil
CopperCopperCopper
T350K3T400K 1
4T400K 2
29.5076.0076.00
ContinuousAmperes
3-PoleCatalog Number
PriceU.S. $
37
15
ELHMCP003A0CELHMCP007C0CELHMCP015E0C
1,225.001,225.001,225.00
253050
ELHMCP025X0CELHMCP030H1CELHMCP050K2C
1,295.001,295.001,645.00
70100150150
ELHMCP070M2CELHMCP100R3CELHMCP150T4CELHMCP150U4C
1,645.001,645.002,335.002,335.00
37
15
ELHMCP003A0LCELHMCP007C0LCELHMCP015E0LC
1,225.001,225.001,225.00
253070
ELHMCP025D0CELHMCP030H1LCELHMCP070J2C
1,295.001,295.001,645.00
ContinuousAmperes
3-PoleCatalog Number
PriceU.S. $
10050
ELHMCP100L3CELHMCP050G2C
1,645.001,645.00
70100
ELHMCP070J2CELHMCP100K3C
1,645.001,645.00
HMCPs for Application with Motor Starters Equipped with Electronic Overload Relays
37
15
ELHMCPS003A0CELHMCPS007C0CELHMCPS015E0C
1,225.001,225.001,225.00
3050
100
ELHMCPS030H1CELHMCPS050K2CELHMCPS100R3C
1,295.001,645.001,645.00
150150
ELHMCPS150T4CELHMCPS150U4C
2,335.002,335.00
ContinuousAmperes
3-PoleCatalog Number
PriceU.S. $
250 ELHMCP250A5ELHMCP250C5ELHMCP250D5ELHMCP250F5ELHMCP250G5ELHMCP250J5ELHMCP250K5ELHMCP250L5ELHMCP250W5
3,230.003,230.003,230.003,230.003,230.003,230.003,230.003,230.003,230.00
400 ELHMCP400D5ELHMCP400F5ELHMCP400G5ELHMCP400J5ELHMCP400K5
5,250.005,250.005,250.005,250.005,250.00
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-2
TAB1205.fm Page 128 Wednesday, October 25, 2000 9:29 PM
12-126
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
January 2001
Molded Case Circuit Breakers
12
Earth Leakage Circuit ProtectorsVol. 1, Ref. No. [0592]
ContentsDescription Page
Earth Leakage Circuit Protectors
Product Description. . . . . . . 12-126
Application Description. . . . 12-126
Options andAccessories . . . . . . . . . . . . 12-126
Technical Dataand Specifications. . . . . . . 12-127
Product Selection . . . . . . . . 12-127
Earth Leakage Circuit Breaker
Typical Earth Leakage Circuit Breaker
Product DescriptionSeries C Earth Leakage Breakers offer superior Class 1 ground fault protection and improved ground fault coordina-tion capability.
Earth leakage ground fault protection differs from other types of systems in its level of sensitivity. The sensitivity of traditional devices is limited by the cumulative error of the residual current sensors and the placement of the phase and neutral conductors inside the current sensor.
Leakage breakers are zero sequence sensing devices. They are factory sup-plied with a single sensor and ground fault relay built-in. This technique allows for protection sensitivities down to the 30 milliampere level.
Leakage breakers are provided with a full complement of easy adjustments. The ground fault pickup setting is adjustable from 0.03 to 30 amperes in eight steps, and the ground fault time delay setting is adjustable from instantaneous to 2.0 seconds in six steps. When the pickup is set to 30 mA, the time delay setting defaults internally to instantaneous only. Increased selectivity provides for improved coordination with upstream and downstream ground fault devices as well as the flexibility to adjust for transient currents.
Application DescriptionThree-Phase, Four-Wire LoadsFor three-phase applications with line-to-neutral loads, select 4-pole earth leakage breakers and wire the neutral through the fourth (right) pole.
Three-Phase, Three-Wire LoadsFor applications with only three-phase, three-wire, line-to-line connected loads, select 3-pole earth leakage breakers.
Single-Phase LoadsFor single-phase, two-wire or three-wire applications, use a 3-pole earth leakage breaker and connect all conductors through the breaker.
GeneralDo not reverse feed. Do not apply on 400 Hz systems.
Options and AccessoriesOptional Factory Installed Internal AccessoriesEarth leakage breakers use the same internal accessories as standard F-, J- and K-Frame Series C Breakers. Internal accessories fit in the right-hand pole space and are available as factory modifications only.
Bell alarm is included as standard.
Optional External AccessoriesSeries C Earth Leakage Breakers use the same external accessories as the standard F-, J- and K-Frame circuit breakers. R.H. only.
TAB1205.fm Page 126 Wednesday, October 25, 2000 9:29 PM