1100 series 1104a-44tg2 diesel engine – electropak

15
Photographs are for illustrative purposes only and may not reflect final specification. All information in this document is substantially correct at time of printing and may be altered subsequently. Publication No. PN1784/09/12 Produced in England ©2012 Perkins Engines Company Limited 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK 79.1 kWm at 1500 rpm 90.2 kWm at 1800 rpm Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs. In the world of power generation success is only gained by providing more for less. With the 1104A-44TG2 Perkins has engineered even higher levels of reliability, yet lowered the cost of ownership. 1100A units are designed for territories that do not require compliance to EPA or EU emissions legislation. These units are able to meet TA luft legislation. Compact, efficient power l 1100 Series is the result of an intensive period of customer research that has guided the development of the range l The new 4.4 litre cylinder block ensures bore roundness is maintained under the pressures of operation. It also ensures combustion and mechanical noise is lowered l A new cylinder head has re-established Perkins mastery of air control Quality by design l Product design and Class A manufacturing improvements enhance product reliability while maintaining Perkins legendary reputation for durability Cost effective power l Compact size and low noise l Lower fuel consumption and oil use l 500 hour service intervals l 2 year warranty Product support l Perkins actively pursues product support excellence by ensuring our distribution network invest in their territory – strengthening relationships and providing more value to you, our customer l Through an experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their fingertips covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine l Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts and service. We give 100% reassurance that you receive the very best in terms of quality for lowest possible cost .. wherever your Perkins powered machine is operating in the world The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on an average alternator efficiency and a power factor (cos. q) of 0.8. Fuel specification: BS 2869: Part 2 1998 Class A2 or DIN EN 590. Lubricating oil: 15W40 to API CG4. Rating Definitions Prime Power: Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours of operation. Standby Power: Variable load. Limited to 500 hours annual usage, up to 300 hours of which may be continuous running. No overload is permitted. Engine Speed (rev/min) Type of Operation Typical Generator Output (Net) Engine Power Gross Net kVA kWe kWm bhp kWm bhp 1500 Prime Power 80.0 64.0 73.4 98.4 71.9 96.4 Standby Power 88.0 70.4 80.7 108.2 79.1 106.1 1800 Prime Power 91.3 73.0 84.5 113.3 82.0 109.9 Standby Power 100.3 80.3 93.0 124.7 90.2 121.0

Upload: others

Post on 25-Dec-2021

19 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Photographs are for illustrative purposes only and may not reflect final specification.

All information in this document is substantially correct at time of printing and may be altered subsequently. Publication No. PN1784/09/12 Produced in England ©2012 Perkins Engines Company Limited

1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

79.1 kWm at 1500 rpm 90.2 kWm at 1800 rpm

Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs.

In the world of power generation success is only gained by providing more for less. With the 1104A-44TG2 Perkins has engineered even higher levels of reliability, yet lowered the cost of ownership.

1100A units are designed for territories that do not require compliance to EPA or EU emissions legislation. These units are able to meet TA luft legislation.

Compact, efficient powerl 1100 Series is the result of an intensive period of customer

research that has guided the development of the range

l The new 4.4 litre cylinder block ensures bore roundness is maintained under the pressures of operation. It also ensures combustion and mechanical noise is lowered

l A new cylinder head has re-established Perkins mastery of air control

Quality by designl Product design and Class A manufacturing improvements

enhance product reliability while maintaining Perkins legendary reputation for durability

Cost effective powerl Compact size and low noise

l Lower fuel consumption and oil use

l 500 hour service intervals

l 2 year warranty

Product supportl Perkins actively

pursues product support excellence by ensuring our distribution network invest in their territory – strengthening relationships and providing more value to you, our customer

l Through an experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their fingertips covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine

l Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts and service. We give 100% reassurance that you receive the very best in terms of quality for lowest possible cost .. wherever your Perkins powered machine is operating in the world

The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited.

Generator powers are typical and are based on an average alternator efficiency and a power factor (cos. q) of 0.8. Fuel specification: BS 2869: Part 2 1998 Class A2 or DIN EN 590. Lubricating oil: 15W40 to API CG4.

Rating Definitions Prime Power: Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours of operation. Standby Power: Variable load. Limited to 500 hours annual usage, up to 300 hours of which may be continuous running. No overload is permitted.

Engine Speed(rev/min)

Type of Operation

Typical GeneratorOutput (Net)

Engine Power

Gross Net

kVA kWe kWm bhp kWm bhp

1500 Prime Power 80.0 64.0 73.4 98.4 71.9 96.4

Standby Power 88.0 70.4 80.7 108.2 79.1 106.1

1800 Prime Power 91.3 73.0 84.5 113.3 82.0 109.9

Standby Power 100.3 80.3 93.0 124.7 90.2 121.0

Page 2: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Photographs are for illustrative purposes only and may not reflect final specification.

All information in this document is substantially correct at time of printing and may be altered subsequently. Publication No. PN1784/09/12 Produced in England ©2012 Perkins Engines Company Limited

Perkins Engines Company LimitedPeterborough PE1 5FQ United Kingdom Telephone +44 (0)1733 583000 Fax +44 (0)1733 582240www.perkins.com

1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

79.1 kWm at 1500 rpm 90.2 kWm at 1800 rpm

Standard ElectropaK specification

Air inletl Mounted air filter

Fuel systeml Rotary type pumpl Ecoplus fuel filter

Lubrication systeml Wet sump with filler and dipstickl Spin-on oil filter

Cooling systeml Thermostatically controlled system with gear-driven

circulation pump and belt-driven pusher fanl Mounted radiator and piping

Electrical equipmentl 12 volt starter motor and 12 volt 65 amp alternator with DC

outputl 12 volt shutdown solenoid energised to run

Flywheel and housingl High inertia flywheel to SAE J620 Size 10/111⁄2l SAE 3 flywheel housing

Mountingsl Front engine mounting bracket

Literaturel User’s Handbook

Optional equipmentl Woodward electronic governor (LCG2)l Workshop manuall Parts book

Fuel Consumption

Engine Speed1500 rev/min 1800 rev/min

g/kWh l/hr g/kWh l/hr

110% of Prime Power 4.5 20.5 5.3 24.4

100% of Prime Power 4.1 18.7 4.9 22.3

75% of Prime Power 3.0 14.0 3.7 16.9

50% of Prime Power 2.1 9.7 2.6 11.9

General dataNumber of cylinders ........................................... 4 vertical in-lineBore and stroke ....................................................105 x 127 mmDisplacement ................................................................ 4.4 litresAspiration ..............................................................TurbochargedCycle ..............................................................................4 strokeCombustion system ..............................................Direct injectionCompression ratio .......................................................... 17.25:1Rotation ...............................Anti-clockwise viewed from flywheelCooling system .......................................................Water-cooledTotal lubrication system capacity.................................... 8.0 litresTotal coolant capacity .................................................. 13.0 litresDimensions – Length .................................................. 1241 mm Width ...................................................... 629 mm Height ..................................................... 951 mmDry weight (approx.) ......................................................... 463 kgFinal weight and dimensions will depend on completed specification

1241 mm

1046 mm

629 mm

951 mm

Page 3: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Document : DS272A/1issue 000 date 11/10/2013

Electrical CharacteristicsFrequency Hz 50 60

Voltage (series star) V 380 400 415 440 415 440 460 480

Rated power class H kVA 85 85 85 70 95 102 102 102

kW 68 68 68 56 76 81,6 81,6 81,6

Rated power class F kVA 77 77 77 63 85,5 92 92 92

kW 61,6 61,6 61,6 50,4 68,4 73,6 73,6 73,6

Regulation with DSR ±1 % with any power factor and speed variations between -5% +30%

Insulation class H

Execution Brushless

Stator winding 12 ends

Rotor with damping cage

Efficiencies class H 4/4 % 91,4 91,5 91,2 91 92,7 93,2 93,3 93,4

(see graph. for details) 3/4 % 91,6 91,9 91,8 91,5 93,3 93,5 93,6 93,8

2/4 % 89,9 90 90 89,8 91,5 91,6 91,7 91,8

1/4 % 86,2 86 85,8 85,8 87,7 87,7 87,7 87,5

Reactances (f. l.cl. F) Xd % 360,1 325 301,9 221,2 404,9 386,8 353,9 325

Xd' % 24,7 22,3 20,7 15,2 27,8 26,5 24,3 22,3

Xd" % 8,2 7,4 6,9 5,0 9,2 8,8 8,1 7,4

Xq % 188,9 170,5 158,4 116,0 212,4 202,9 185,6 170,5

Xq' % 188,9 170,5 158,4 116,0 212,4 202,9 185,6 170,5

Xq" % 32,7 29,5 27,4 20,1 36,8 35,1 32,1 29,5X2 % 21,3 19,2 17,8 13,1 23,9 22,8 20,9 19,2X0 % 4,0 3,6 3,3 2,5 4,5 4,3 3,9 3,6

Short Circuit Ratio Kcc 0,45 0,50 0,62 1,07 0,35 0,40 0,45 0,50

Time Constants Td' sec. 0,04192

Td" sec. 0,00575

Tdo' sec. 1,50Tα sec. 0,0154

Short Circuit Current Capacity % >300 >350

Excitation at no load Amp. 0,4 0,5 0,7 1 0,2 0,3 0,4 0,7

Excitation at full load Amp. 2,2 2,3 2,5 2,8 1,9 2 2,1 2,2

Overload (long-term) % 1 hour in a 6 hours period 110% rated load

Overload per 20 sec. % 300

Stator Winding Resistance (20°C) Ω 0,03

Rotor Winding Resistance (20°C) Ω 2,477

Exciter Resistance (20 °C) Ω Rotor : 0,410 Stator : 15,28

Heat dissipation at f.l.cl.H W 6398 6317 6561 5538 5985 5954 5860 5766

Telephone Interference THF < 2% TIF < 40

Radio interferenceWaveform Distors.(THD) at f. load LL/LN % 1,6 / 1,8

Waveform Distors.(THD) at no load LL/LN % 2,9 / 3

Mechanical characteristicsProtection IP 21 ( other protection on request )

DE bearing 6314.2RS

NDE bearing 6311.2RS

Weight of wound stator assembly kgWeight of wound rotor assembly kg 63

Weight of complete generator kgMaximun overspeed rpm 2250

Unbalanced magnetic pull at f.l.cl.F kN/mm 4,9

Cooling air requirement m³/min 19,3 23

Inertia Constant (H) sec. 0,111 0,133Noise level at 1m/7m dB(A) 79 / 65 83 / 69

This document is a propriety of Mecc Alte S.p.a..All rights reserved.

EN61000-6-3, EN61000-6-2. For others standards apply to factory

GENERATOR TYPE ECP 34-1S/4 A

All technical data are to be considered as a reference and they can be modified without any notice.

97

331

Page 4: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Document : DS272A/2issue 000 date : 11/11/2013

This document is a propriety of Mecc Alte S.p.a.. All rights reserved.

GENERATOR TYPE ECP 34-1S/4 A

50 Hz

85

86

87

88

89

90

91

92

93

94

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

380/50

0,8 p.f.

1 p.f.

85

86

87

88

89

90

91

92

93

94

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

1 p.f.

0,8 p.f.

400/50

85

86

87

88

89

90

91

92

93

94

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

1 p.f.

0,8 p.f.

85

86

87

88

89

90

91

92

93

94

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

1 p.f.

0,8 p.f.

0

10

20

30

40

0 1 2 3 4

Vol

tage

dip

%

380/50

Current p.u.

0,8 p.f.

1 p.f.

0 p.f.

0

10

20

30

40

0 1 2 3 4

Vol

tage

dip

%

Current p.u.

400/50

0 p.f.

0,8 p.f.

1 p.f.

0

10

20

30

40

0 1 2 3 4

Vol

tage

dip

%

Current p.u.

0 p.f.

0,8 p.f.

1 p.f.

415/50

440/50

415/50

0

10

20

30

0 1 2 3 4

Vol

tage

dip

%

Current p.u.

0 p.f.

0,8 p.f.

1 p.f.

1

10

100

1000

10000

0,001 0,01 0,1 1 10

Am

pere

s

Three phase short circuit decrement curve. No load excitation at rated speed

Seconds

Asymmetrical

Symmetrical

440/50

Page 5: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Document : DS272A/3issue 000 date : 11/11/2013

This document is a propriety of Mecc Alte S.p.a.. All rights reserved.

GENERATOR TYPE ECP 34-1S/4 A

60 Hz

87

88

89

90

91

92

93

94

95

96

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

415/60

0,8 p.f.

1 p.f.

87

88

89

90

91

92

93

94

95

96

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

1 p.f.

0,8 p.f.

440/60

87

88

89

90

91

92

93

94

95

96

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

1 p.f.

0,8 p.f.

87

88

89

90

91

92

93

94

95

96

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1

Effi

cien

cy %

Load p.u.

1 p.f.

0,8 p.f.

0

10

20

30

40

50

0 1 2 3 4

Vol

tage

dip

%

415/60

Current p.u.

0,8 p.f.

1 p.f.

0 p.f.

0

10

20

30

40

50

0 1 2 3 4

Vol

tage

dip

%

Current p.u.

440/60

0 p.f.

0,8 p.f.

1 p.f.

0

10

20

30

40

0 1 2 3 4

Vol

tage

dip

%

Current p.u.

0 p.f.

0,8 p.f.

1 p.f.

460/60

480/60

460/60

0

10

20

30

40

0 1 2 3 4

Vol

tage

dip

%

Current p.u.

0 p.f.

0,8 p.f.

1 p.f.

1

10

100

1000

10000

0,001 0,01 0,1 1 10

Am

pere

s

Three phase short circuit decrement curve. No load excitation at rated speed

Seconds

Asymmetrical

Symmetrical

480/60

Page 6: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK
Page 7: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK
Page 8: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

UCI224G - Technical Data Sheet

Page 9: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

UCI224GSPECIFICATIONS & OPTIONS

STANDARDSNewage Stamford industrial generators meet therequirements of BS EN 60034 and the relevant sectionof other international standards such as BS5000, VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator(AVR) to the exciter stator. The high efficiencysemiconductors of the AVR ensure positive build-upfrom initial low levels of residual voltage.The exciter rotor output is fed to the main rotor througha three phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surgescaused, for example, by short circuit.

SX440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor througha three-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surgescaused, for example, by short circuit or out-of-phaseparalleling.The SX440 will support a range of electronicaccessories, including a 'droop' Current Transformer(CT) to permit parallel operation with other acgenerators.If 3-phase sensing is required with the self-excitedsystem, the SX421 AVR must be used.

SX421AVRThis AVR also operates in a self-excited system. Itcombines all the features of the SX440 with,additionally, three-phase rms sensing for improvedregulation and performance. Over voltage protection isprovided via a separate circuit breaker. An engine reliefload acceptance feature is built in as standard.

MX341 AVRThis sophisticated AVR is incorporated into theStamford Permanent Magnet Generator (PMG) controlsystem.The PMG provides power via the AVR to the mainexciter, giving a source of constant excitation powerindependent of generator output. The main exciteroutput is then fed to the main rotor, through a full wavebridge, protected by a surge suppressor. The AVR hasin-built protection against sustained over-excitation,caused by internal or external faults. This de-excitesthe machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.If three-phase sensing is required with the PMG systemthe MX321 AVR must be used.We recommend three-phase sensing for applicationswith greatly unbalanced or highly non-linear loads.

MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phaserms sensing, for improved regulation and performance.Over voltage protection is built-in and short circuitcurrent level adjustments is an optional facility.

WINDINGS & ELECTRICAL PERFORMANCEAll generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimumdesign for trouble-free supply of non-linear loads. The2/3 pitch design avoids excessive neutral currentssometimes seen with higher winding pitches, when inparallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. Thiswinding, with the 2/3 pitch and carefully selected poleand tooth designs, ensures very low waveformdistortion.

TERMINALS & TERMINAL BOXStandard generators are 3-phase reconnectable with 12ends brought out to the terminals, which are mountedon a cover at the non-drive end of the generator. Asheet steel terminal box contains the AVR and providesample space for the customers' wiring and glandarrangements. It has removable panels for easyaccess.

SHAFT & KEYSAll generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with ahalf key.

INSULATION/IMPREGNATIONThe insulation system is class 'H'.All wound components are impregnated with materialsand processes designed specifically to provide the highbuild required for static windings and the highmechanical strength required for rotating components.

QUALITY ASSURANCEGenerators are manufactured using productionprocedures having a quality assurance level to BS ENISO 9001.

The stated voltage regulation may not be maintained inthe presence of certain radio transmitted signals. Anychange in performance will fall within the limits ofCriteria 'B' of EN 61000-6-2:2001. At no time will thesteady-state voltage regulation exceed 2%.

NB Continuous development of our products entitles usto change specification details without notice, thereforethey must not be regarded as binding.

Front cover drawing typical of product range.

2

Page 10: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.

A.V.R. MX321 MX341

VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT

CONTROL SYSTEM SELF EXCITED

A.V.R. SX460 SX440 SX421

VOLTAGE REGULATION ± 1.5 % ± 1.0 % ± 0.5 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT

INSULATION SYSTEM CLASS H

PROTECTION

RATED POWER FACTOR

STATOR WINDING

WINDING PITCH

WINDING LEADS

STATOR WDG. RESISTANCE

ROTOR WDG. RESISTANCE

EXCITER STATOR RESISTANCE

EXCITER ROTOR RESISTANCE

R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%

MAXIMUM OVERSPEED

BEARING DRIVE END

BEARING NON-DRIVE END

WEIGHT COMP. GENERATOR

WEIGHT WOUND STATOR

WEIGHT WOUND ROTOR

WR² INERTIA

SHIPPING WEIGHTS in a crate

PACKING CRATE SIZE

TELEPHONE INTERFERENCE

COOLING AIR

VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277

VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138

VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138kVA BASE RATING FOR REACTANCE VALUES

85 85 85 79 93.8 97.5 100 103.8

Xd DIR. AXIS SYNCHRONOUS 2.43 2.20 2.04 1.69 2.66 2.47 2.32 2.21

X'd DIR. AXIS TRANSIENT 0.19 0.17 0.16 0.13 0.20 0.19 0.17 0.17

X''d DIR. AXIS SUBTRANSIENT 0.13 0.12 0.11 0.09 0.14 0.13 0.12 0.12

Xq QUAD. AXIS REACTANCE 1.12 1.01 0.94 0.78 1.22 1.13 1.06 1.01

X''q QUAD. AXIS SUBTRANSIENT 0.17 0.15 0.14 0.12 0.15 0.14 0.13 0.12

XL LEAKAGE REACTANCE 0.07 0.06 0.06 0.05 0.08 0.07 0.07 0.07

X2 NEGATIVE SEQUENCE 0.16 0.14 0.13 0.11 0.15 0.14 0.13 0.12

X0 ZERO SEQUENCE 0.11 0.10 0.09 0.07 0.11 0.10 0.10 0.09

REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST.T''d SUB-TRANSTIME CONST.T'do O.C. FIELD TIME CONST.Ta ARMATURE TIME CONST.

SHORT CIRCUIT RATIO

20 Ohms at 22°C

0.078 Ohms PER PHASE AT 22°C

REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)

BALL. 6309-2RS (ISO)

0.94 Ohms at 22°C

0.055 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED

BALL. 6312-2RS (ISO)

1/Xd

0.03 s0.008 s0.75 s0.007 s

126.75 kg

0.7136 kgm2

IP23

0.8

DOUBLE LAYER CONCENTRIC

TWO THIRDS

12

400 kg383 kg

139 kg

UCI224G

0.216 m³/sec 458 cfm 0.281 m³/sec 595 cfm

50 Hz

THF<2%

60 Hz

TIF<50

118.38 kg

0.6818 kgm2

WINDING 311

1 BEARING 2 BEARING

2250 Rev/Min

139 kg

420 kg

105 x 57 x 96(cm)

404 kg

105 x 57 x 96(cm)

3

Page 11: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Winding 311UCI224G

THREE PHASE EFFICIENCY CURVES

50Hz

4

Page 12: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Winding 311UCI224G

THREE PHASE EFFICIENCY CURVES

60Hz

5

Page 13: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

UCI224GWinding 311

Locked Rotor Motor Starting Curve

MX SX

50Hz

60Hz

MX SX

0

5

10

15

20

25

30

0 50 100 150 200 250 300LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

346V 380V 400V 415V 440V

0

5

10

15

20

25

30

0 50 100 150 200 250LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

346V 380V 400V 415V 440V

0

5

10

15

20

25

30

0 50 100 150 200 250 300 350LOCKED ROTOR kVA

PE

R C

EN

T TR

AN

SIE

NT

VO

LTA

GE

DIP

380V 416V 440V 460V 480V

0

5

10

15

20

25

30

0 50 100 150 200 250 300LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

380V 416V 440V 460V 480V

6

Page 14: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

3-phase 2-phase L-L 1-phase L-NVoltage Factor Voltage Factor x 1.00 x 0.87 x 1.30

380v X 1.00 416v X 1.00 x 1.00 x 1.80 x 3.20400v X 1.07 440v X 1.06 x 1.00 x 1.50 x 2.50415v X 1.12 460v X 1.12 10 sec. 5 sec. 2 sec.440v X 1.18 480v X 1.17

UCI224G

50Hz 60Hz

The sustained current value is constant irrespectiveof voltage level

Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated SpeedBased on star (wye) connection.

Max. sustained durationAll other times are unchanged

Instantaneous

SustainedMinimum

Sustained Short Circuit = 390 Amps

Sustained Short Circuit = 460 AmpsNote 1The following multiplication factors should beused to adjust the values from curve betweentime 0.001 seconds and the minimum currentpoint in respect of nominal operating voltage :

Note 2The following multiplication factor should be used to convert thevalues calculated in accordance with NOTE 1 to those applicableto the various types of short circuit :

Note 3Curves are drawn for Star (Wye) connected machines. For otherconnection the following multipliers should be applied to currentvalues as shown : Parallel Star = Curve current value X 2Series Delta = Curve current value X 1.732

50Hz

60Hz

10

100

1000

10000

0.001 0.01 0.1 1 10TIME (secs)

CU

RR

EN

T (A

mp

s)

SYMMETRICAL

ASYMMETRICAL

100

1000

10000

0.001 0.01 0.1 1 10TIME (secs)

CU

RR

EN

T (A

mp

s)

SYMMETRICAL

ASYMMETRICAL

7

Page 15: 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK

Class - Temp Rise

Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440

Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220

Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254

kVA 75.0 75.0 75.0 67.4 85.0 85.0 85.0 75.0 87.5 87.5 87.5 76.9 90.8 90.8 90.8 80.1

kW 60.0 60.0 60.0 53.9 68.0 68.0 68.0 60.0 70.0 70.0 70.0 61.5 72.6 72.6 72.6 64.1

Efficiency (%) 90.3 90.6 90.7 91.0 89.8 90.2 90.4 90.8 89.7 90.1 90.3 90.7 89.6 89.9 90.1 90.6

kW Input 66.4 66.2 66.2 62.4 75.7 75.4 75.2 69.6 78.0 77.7 77.5 71.4 81.1 80.8 80.6 74.5

Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480

Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240

Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277

kVA 87.5 90.0 93.8 95.0 93.8 97.5 100.0 103.8 98.1 102.5 102.5 110.0 101.3 106.3 106.3 113.8

kW 70.0 72.0 75.0 76.0 75.0 78.0 80.0 83.0 78.5 82.0 82.0 88.0 81.0 85.0 85.0 91.0

Efficiency (%) 90.8 91.0 91.1 91.3 90.5 90.8 90.9 91.0 90.3 90.6 90.9 90.9 90.2 90.4 90.7 90.8

kW Input 77.1 79.1 82.4 83.2 82.9 85.9 88.0 91.3 86.9 90.5 90.2 96.8 89.8 94.1 93.8 100.3

TD_UCI224G.GB_12.03_04_GB

Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C

DIMENSIONS

UCI224GWinding 311 / 0.8 Power Factor

RATINGS

Barnack Road • Stamford • Lincolnshire • PE9 2NBTel: 00 44 (0)1780 484000 • Fax: 00 44 (0)1780 484100Website: www.newage-avkseg.com

© 2004 Newage International Limited.Reprinted with permission of N.I. only.Printed in England.

50Hz

60Hz