11 case for co axis angled implants
DESCRIPTION
Guide Right Surgical Guide System: fabrication and correction of Diagnostic & Surgical Guides with 2D & 3D X-ray ImagesTRANSCRIPT
Guide Right™
CASE FOR ANGLED IMPLANTS
ZHEN 2.2013
# 10 & # 6 Vacuform Shell Offset Guide Posts Open Guide Sleeves Evaluation using Software Lineal Corrections Angular Corrections
Invivo5
Featuring:
Vacuform 3 mm guide posts 3 mm guide sleeves
Fabrication of DIAGNOSTIC guide
Cast of the patient as he presented at initial exam.
Temporary partial denture
Impression and cast with partial denture in place.
Vacuform shell on cast marked to indicate the planned axis holes for the implants.
Holes are drilled through the plastic shell into the incisal edge with 3/32” drills.
Vacuform shell on cast with holes drilled indicatingthe proposed axis holes for the implants.
The vacuform shell removed.
The drills are removed and replaced with two short 3 mm straight guide posts.
3 mm diagnostic guide sleeves (with 1 cleat) are placed on the guide posts with cleats positioned on the palatal surface.
Triad® Gel is applied capturing the cleats on the guide posts and adjacent teeth to form the DIAGNOSTIC guide
which is used for the cone beam imaging.
PREOPERATIVE
Software EvaluationInvivo5 Anatomage
# 6
# 6Initial Alignment of guide sleeve with implant
axial cross sectional
tangential view volumetric
Invivo5 Anatomage
Cone beam image showing alignment of the guide sleeve in the # 6 position. A 12 º bend is required for this site.
# 6Utilizing 12º Angled Southern Implant ▪
axial cross sectional
tangential view volumetric
Invivo5 Anatomage
Southern Implant & Guide Right™ Guide Sleeve in Place
▪ 12º facial correction needed to place implant ▪
cross sectional view
#6
Invivo5Anatomge
# 6Initial Alignment of guide sleeve with implant
axial cross sectional
tangential view volumetric
Invivo5 Anatomage
The guide sleeve is in line with the virtual implant, but close to root of #5. So a 1.5 mm offset post will be used to move the position of the guide sleeve to the mesial.
# 6
tangential viewInvivo5
Anatomage
PREOPERATIVE
Software EvaluationInvivo5 Anatomage
# 10
Invivo5Anatomage ▪ Initial Alignment ▪
occlusal cross sectional
tangential view volumetric
Invivo5Anatomage
#10Showing virtual implant and the guide sleeve in two planes.
#10 A Southern 12° Co-axis Implant will be used, Angular Correction for guide sleeve: 12º toward the facial
Invivo5Anatomage
cross sectional
Invivo5Anatomage
▪ Southern Implant 12º co-axis virtual image ▪
Linear Correction:
1 mm offset guide post > moving closer to root of # 11
# 10
tangential viewInvivo5Anatomage
Fabrication of SURGICAL guide
Magnetic Guide Posts
Open Guide Sleeves
Fabrication of SURGICAL Guide
Magnetic Guide Posts
Open Guide Sleeves
Corrected magnetic offset guide posts in place: # 6 > 1.5 mm offset guide post to move mesially, away from # 5 #10 > 1.0 mm offset guide post to move distally, closer to # 11
3.3 mm open guide sleeves positioned over the magnetic guide posts with cleats positioned toward the palatal surface.
Triad® Gel is added to form the completed SURGICAL guide.
POST-OPERATIVE
Final X-rays
Final X-rays of implant placement
# 10# 6
RESTORATION
Axis indicator (3 mm guide posts) in place
Posts indicating the long axis of the abutments
Atlantis abutments
Final restoration
Final restoration
Atlantis Abutment
Final Restoration
Final Restoration
Step 2 Locate 3/32” hole in the center of the v-cut and place the bottom half of the guide post into the hole. Tighten the set screw.
Step 1 Place bending tool plate on a secure flat surface with the degree increments at the top & the stainless steel bar with the v-cut at the bottom.
Step 3 Locate the hole in the bottom of the stylus that you will use that will fit over the top half of the guide post (3.0 mm, 4.0 mm or 5.0 mm).
Step 5 Using the stylus as a lever, bend the guide post to the degree of angle of correction. You may need to ease the point of the stylus beyond the point of the desired degree.
Step 6 Loosen screw and remove guide post and the stylus to find the guide post bent to the desired angle.
Step 4 Fit the stylus over the guide post securely with the point directed at zero degrees and the bottom of the stylus in contact with the V block.
Guide Right™ GENERATION II BENDING TOOL
SINGLE BEND review
COMPOUND BEND overview
Step 1 Position a straight or offset guide post in the bending plate, tightening the set screw against one of the flat surfaces on the lower half of the guide post.
Step 4 The 2nd bend in the second plane is made after rotating the guide post up away from the surface of the bending plate to register the stylus point back at 0 degrees.Step 5 Slide the stylus support bar down under the stylus until it supports the stylus. Tighten the side screws before making the second bend.
Step 7 Remove the stylus and place the guide post back in the cast with the appropriate side indicated by a mark facing the buccal or lingual surface.
Be sure the post is in the correct position.If the post needs to be corrected by a linear movement an offset guide post can be used.
Off sets available in the 3 mm guide post: 0.5,1,1.5, 2.0 ,or 3.0 mm.
Step 3 The set screw is loosened and the guide post is rotated 90 ° next flat surface.
Step 2 The 1st bend can be made to the right or left direction.
Step 6 The second bend can be made in either direction according to the x-ray.
Guide Right™ GENERATION II BENDING TOOL
Guide Right™
Generation ll Bending Tool
For more information on use of the bending tool go towww.deplaque.com ▪ Guide Right™ Generation ll Bending Tool
10 ° example
Close up of Offset Guide Posts in bending block
Guide Right™
Generation ll Bending Tool
Magnetic Guide Posts
Straight 3.0 mm od Offset
3.0 od X 0.5 mm os
3.0 od X 1.0 mm os
3.0 od X 1.5 mm os
3.0 od X 2.0 mm os
3.0 od X 2.5 mm os
3.0 od X 3.0 mm os
Guide Right™ Products shown in this case
2 - 3/32” Drill
2 - 3 mm Straight Guide Posts (short)
2 - 3 mm Guide Sleeves
1 - 3 mm X 1.0 mm Offset Magnetic Guide Post
1 - 3 mm X 1.5 mm Offset Magnetic Guide Post
2 - 3 mm Open Guide Sleeve
Generation ll Bending Tool
Triad® Gel
In-office or lab fabrication
Evaluate with 2D & 3D imaging
Allows linear and angular correction
Enables precision implant placement
Cost effective
A System of Components
for the fabrication and correction of DIAGNOSTIC & SURGICAL guides in one or two dimensions
1.800.314.0065 • www.deplaque.com
Guide Right™ Surgical Guide System
Start With Precision. Place With Confidence.™
1.800.314.0065 • www.deplaque.com
fabricate ▪ evaluate ▪ correct ▪ verify ▪ place