1 transtl&gi pendahuluan
DESCRIPTION
Materi pembelajaran Transmisis dan Gardu induk.TRANSCRIPT
-
Transmisi Tenaga Listrik danGardu Induk1. Pendahuluan
-
Materi
-
Buku acuanAnalisis Sistem Tenaga Listrik, William D. Stevenson Jr.Transmisi Daya Listrik, T.S. HutaurukElectrical Machines, Drives, and Power Systems, Theodore Wildi
-
STLSubsistem PembangkitSubsistem TransmisiSubsistem Distribusi* Beban Provide, at all times, the power that consumers needMaintain a stable, nominal voltage that does not vary by more than 10%Maintain a stable frequency that does not vary y more than 0.1%Supply energy at an acceptable priceMeet standards of safetyRespect environmental standard
-
STL
500kV
500kV
500kV
150kV
500kV
150kV
150kV
20kV
150kV
Belasan kV
KonsumenBesar
KonsumenBesar
KonsumenKecil
GarduDistribusi
G I
G I
G I
G I
G I
380V
Sistem Tenaga Listrik
150kV
G I
G I
G I
150kV
20kV
-
Saluran Transmisi 500 kV Jawa
-
Saluran transmisi 150 kV Jateng DIY
-
Asean
-
TeganganStandar Listrik Indonesia No.:SNI 0277-1987-C, SLI 036-1986A.11
Tabel III : Sistem arus bolak-balik bertegangan nominal di atas 35 kV sampai dengan 220 kV dan perlengkapan terpasangTabel IV : Sistem arus bolak-balik bertegangan tertinggiuntuk perlengkapan di atas 245 kV
Tegangan tertinggi untuk perlengkapan(kV)Tegangan sistem nominal(kV)72,514517024566132150220
Tegangan tertinggi untuk perlengkapan(kV)300525
-
Tegangan380 V JTR20 kV JTM150 kV 500 kV JTT
SUTR, SKTRSUTM, SKTMSUTT, SKTTSUTET
-
Medan Listrik dan Medan MagnetWHO menggolongkan medan listrik dan medan magnet sebagai radiasi tidak mengion (non- ionizing radiation) dikarenakan tidak mempunyai efek untuk memecah atom atau molekul yang dilaluinya.WHO atas usulan International Non-Ionizing Radiation Committee / International Radiation Protection Association (INIRC/IRPA) menetapkan ambang batas medan listrik dan medan magnet yang tidak membahayakan kesehatan manusia.