Page 1: 1. Swing Master Joint Type - تبلیغات برترgpeco.com/admin/imgs/1493621321.1500-Floating Suction or Skimming... · a) Bolt the swing joint to the tank nozzle flange. Do not

12Persian GPE

Page 2: 1. Swing Master Joint Type - تبلیغات برترgpeco.com/admin/imgs/1493621321.1500-Floating Suction or Skimming... · a) Bolt the swing joint to the tank nozzle flange. Do not

1. Swing Master Joint Type2. Swivel Joint Type

Arms GroupSkimming System

Page 3: 1. Swing Master Joint Type - تبلیغات برترgpeco.com/admin/imgs/1493621321.1500-Floating Suction or Skimming... · a) Bolt the swing joint to the tank nozzle flange. Do not

14Persian GPE

Application:The basic task of GPE suction system is discharge of the pure fuel from top of the contents to minimize possibility of any slug existence in discharged product.GPE oil suction units are being supplied with swing master joint and pipe work, floaters are available in either aluminum or stainless steel up on requests.The oil suction unit safeguards the quality of product drawn off from the tank.Both flanges of the swing joint are cast iron raised faced flanges ANSI B16.5 Class 150. Bolt holes should be straddle bushing center lines on all sizes except 10» and 12in which are on bushing center lines.

Use the following installation procedure to prevent damage to swing joint flanges:

1. Mating pipe flanges must be parallel and aligned properly to prevent undue pipe bending stresses.

2. Class 150 raised face flanges must use a full face gasket and be mated only with a flat face flange. Do not use a ring gasket which fits inside the bolt circle or a raised face flange as they can cause bending loads severe enough to crack the cast iron flange on the swing joint.

3. ANSI B16.1 standard for cast iron pipe flanges recommends bolting no stronger than ASTM A307 Grade B. Tapped holes in yoke require studs with UNC (Unified National Coarse) threads.

• Model No. 1550• Unit Swing Master Joint• Sizes 12in through 24in• Single Arm • Easy Maintenance• Wide Range of Materials

Floating Suction SystemSwing Master Joint Type

Page 4: 1. Swing Master Joint Type - تبلیغات برترgpeco.com/admin/imgs/1493621321.1500-Floating Suction or Skimming... · a) Bolt the swing joint to the tank nozzle flange. Do not

16Persian GPE

Application:The Main task of GPE Skimmers are accumulation and discharge of tank content top layer of fluid out from the tank. GPE Skimmer units are being supplied with swivel joint and pipe work, floats are available in either aluminum or stainless steel upon customer request.The suction unit safeguards the quality of product drawn off from the tank.

Feature and Benefits:The units are designed to maintain the intake approximately 150-50 mm below the liquid surface and the intake is effectively baffled to avoid vortex formation.The suction is fitted with a low level stop to prevent disturbance of any water or sediment in the tank bottom. All the swivel joints have been designed for fully immersed service with two widely spaced raceways each with a full compliment of large diameter stainless steel balls.The swivel seals are suitable for both vacuum and pressure service enabling, and the swivels are packed for life with grease that is fully compatible with aviation fuels. Foam Skimmer units are available in suitable configurations to pass through tank entrance manhole.

Floating Foam Oil Suction (Skimmer)Swivel Joint Type

• Model No. 1600 • Unit Swivel Joint Type• Sizes 3in through 10in• Single & Double Arms• Top, Center or Bottom Outlet• Fully Immersed Service• Easy Maintenance

Page 5: 1. Swing Master Joint Type - تبلیغات برترgpeco.com/admin/imgs/1493621321.1500-Floating Suction or Skimming... · a) Bolt the swing joint to the tank nozzle flange. Do not

15 Persian GPE

4. The swing joint should be leveled during installation to insure the swing pipe pivots in a vertical plane.a) Bolt the swing joint to the tank nozzle flange. Do not completely tighten the bolts. Rotate the tee flange looking up.b) Lugs are cast on the bottom of the yoke to center the pipe supports. Use standard pipe supports and floor flanges to carry the weight of the swing joint to the tank bottom. Do not tighten supports until swing joint is level.c) Place a level inside the tee long enough to rest on the inside diameter of both bushings.d) The clearance between the flange holes and bolts

:

3

Floating Oil Suction Schematic

will allow a small rotational adjustment of the yoke. When a good level is obtained, cross tighten the bolts.

5. A cross-bolt tightening technique for uniform flange stress and gasket loading should be used on both swing joint flanges.6. Routine maintenance is not required; however, each time the tank is opened the swing joint should be inspected.

Page 6: 1. Swing Master Joint Type - تبلیغات برترgpeco.com/admin/imgs/1493621321.1500-Floating Suction or Skimming... · a) Bolt the swing joint to the tank nozzle flange. Do not

Skimmer System Data SheetSkimmer System Data SheetPleaase kindly fill the below form to Persian GPE for providing Technical Proposal:

General

Contractor : Tank Diameter (mm) :

Order No : Tank Height (mm) :

Tank Quantity : Tank Tag (mm) :

Skimmer Size (in) :

Roof Drain Nozzle Specification Nozzle Orientation

D1 (mm) = E1 (mm) = High High Liquid Level Position (mm) "HHLL":

D2 (mm) = Low Low Liquid Level Position (mm) "LLLL":

E2 (mm) =ß (Deg) = Tank Bottom Slop (%) : Up Down

Distance From Inside Shell to Face Of Shell Outlet Nozzle Flange (mm) "F1":

Distance From Tank Bottom To Center Line Of Shell Outlet Nozzle Flange (mm) "F2" :

Floater Specification

Length of Floater : mm

Diameter of Floater "Ø" : mm

No Of Floater Per Tank :

Design procedure should be assumed specific gravity 0.7 and buancy level calculated as per specific gravity og 1 (Water)

Note : All presented photos are for illustration purpose only.The details may vary according to inquiry specifications which have been presented on general drawings.

Skimmer Type Specification

Skimmer System Type : A B C

TYPE A (One Arm)

Length of Arm (mm) "L1" : mm

TYPE B (Two Arms)

Length of Primary Arm (mm) "L1" : mm

Length of Secondary Arm (mm) "L2" : mm

TYPE C (Three Arms)

Length of Primary Arm (mm) "L1" : mm

Length of Secondary Arm (mm) "L2" : mm

Length of Third Arm (mm) "L3" : mm

Note : All presented photos are for illustration purpose only.The details may vary according to inquiry specifications which have been presented on general drawings.

Page 7: 1. Swing Master Joint Type - تبلیغات برترgpeco.com/admin/imgs/1493621321.1500-Floating Suction or Skimming... · a) Bolt the swing joint to the tank nozzle flange. Do not

18Persian GPE

Skimmer Type SpecificationSkimmer System Type : A B C

TYPE A (One Arm)

Length of Arm (mm) "L1" : mm

TYPE B (Two Arms)

Length of Primary Arm (mm) "L1" : mm

Length of Secondary Arm (mm) "L2" : mm

TYPE C (Three Arms)

Length of Primary Arm (mm) "L1" : mm

Length of Secondary Arm (mm) "L2" : mm

Length of Third Arm (mm) "L3" : mm

Note : All presented photos are for illustration purpose only.The details may vary according to inquiry specifications which have been presented on general drawings.