1 selling addressable panels selling addressable fire alarm systems ms-9050ud selling addressable...
TRANSCRIPT
1
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Addressable SystemsMS-9050UD
2
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Product Overview
• MS-9050UD• Ideal for small to medium facilities• Perfect for replacing conventional systems• A single PC board, includes all electronics,
• 3 amp power supply, • Built-in digital communicator
• Optional Internet Communicator (IPDACT)• Converts DACT-UD signals to Ethernet• Planned for January 2007 release (Pending UL)
3
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Product Overview
• MS-9050UD Continued• Easy to Install, Program and Use• Meets many application requirements• Features new larger enclosure with
electronics on easy-to-remove chassis.
4
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Product Overview
• Look and feel of larger FireLite addressable panels• Menus and selections follow standard
FireLite panels and reduce training required. • Support for 50 addressable devices of any
type on one signaling line circuit.
5
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Product Overview
• MS-9050UD Continued• Standard features:
• User-friendly LCD Display, • 2 NAC circuits with built-in synchronization for
System Sensor, Wheelock, and Gentex• 3 Form-C relays standard
• Trouble (non-programmable)• Alarm and Supervisory are programmable for
other functions• 3-amp power supply
6
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Product Overview
• Programming Options• From the front panel keyboard or PS-2 Keyboard
• A standard PC keyboard can be plugged into the board's PS-2 connector to facilitate keystrokes.
• From any computer serving as a programming terminal• Requires Windows®-98 or greater, a modem and Fire-
Lite's PK-CD Upload/Download software kit (available Q4, 2006)
• Information that can be retrieved includes:• The History file• Walk test data• Current status and system voltages
7
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Options
• ANN-80 Remote Annunciator Liquid Crystal Display • 80-Character Display (4 lines 20 characters
each)• Provides complete event description
• Maximum of 8 per system, 6,000 feet max between each
• Permits remote displays at convenient building locations
• Switches for the remote execution of Acknowledge, Alarm Silence, Reset and Drill functions
• Permits system control from remote location• Access controlled by key switch
• Prohibits unauthorized operation
8
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Options
• ANN-I/O• Lamp Driver module for interfacing with
custom graphic annunciator displays• Permits first responders/fire fighters to
quickly locate devices in alarm
6000 ft
EIA-485
ANN-I/O
Graphic Annunciator
9
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Options
• Ann-S/PG Printer Gateway• Allows serial or parallel printer to be placed
anywhere on ANN-Bus• 6,000 feet max from panel
• Permits remote printer at convenient building locations• Supports new UL listed PRN-6F printer or any low-
cost serial or parallel printer
6000 ft
EIA-485
10
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Options
• ANN-LED• LED Annunciator module
• Can be mounted in special dress panel DP-5150LED for applications where LED’s are required.
• TR-CE Trim Ring• Continuous Metal trim ring dresses panel for flush
mount up to hinge of panel door.
11
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Options
• 4XTMF Transmitter Module • Reverse Polarity
Alarm and Trouble transmitter
• Permits connection to municipal central stations
12
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Target Markets (Who will Buy this System?)• Smaller facilities including:
• - Apartment Complexes• - Banks• - Cinemas• - Child Care and Elementary Schools• - Department Stores• - Food Stores• - Places of Worship• - Restaurants• - Strip Malls• - Small Retail Outlet Stores
13
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Mid-Rise building targets• Buildings less than 75 feet in
height:• Dormitories• Small Motels• Small Hotels• Extended Stay Facilities
14
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Vertical Market targets • Commercial buildings including:
• Light Manufacturing• Stand Alone Warehouse• Telecommunication Systems• Smaller Corporate Headquarters
• Healthcare including:• Smaller Hospitals and Clinics• Nursing Homes• Retirement or Assisted Living Facilities
15
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Typical Customer Profiles (Who do I talk to?)• Security or Facility Manager in a Small to
Mid-Sized Business or Public Facility:• Example: A building such as a small or
elementary school or day care facility or place of worship.
• Building Owner or Contractor:• Examples: A standalone department store or
municipal building
16
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Qualifying Questions • (Determine customer need and overcome objections.)
• How dispersed are the devices from the panel?• The MS-9050UD's SLC loop can be up to 10,000 feet
long.
• What type of building is it? (Motel, Assisted living, Department Store)• A single MS-9050UD can support up to 50 devices of
any type, detectors or modules. • Built-in software logic zones can be programmed to
meet any critical need.
17
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Are you constrained by budget limitation?• For smaller applications, the MS-9050UD is
a compact, cost effective Fire Alarm• Built-in Control Panel/Communicator that
provides large system technology and quality at a reasonable price.
18
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Selling Points• Designed for small sized installations• User-friendly interface for easier
programming and maintenance• Compliance - UL 864 (Fire), NFPA-72 and ULC• Supports a wide range of addressable
sensors:• Photo, Ion, Beam, Heat detectors, Duct Detectors
and all the SLC devices supported by FireLite’s larger products
19
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Selling Strategies
• Selling Points (Continued)• Supports a variety of notification devices
such as: • Horns and Strobes (including SpectrAlert
Advance Selectable Output Series of strobes, horns/strobes and speaker/strobes)
• Integrates or retrofits existing conventional devices
• Drop in upgrade for MS-9200 • Uses existing wire• Uses existing intelligent devices
20
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Features and BenefitsFEATURE BENEFIT
One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6, or 7.
The MS-9050UD's 1-loop system supports 50 devices of any type.
Standard 80-character LCD backlit display, (4 lines x 20 characters).
Easy to Use and very intuitive. Allows programming without any additional hardware required.
Four (4) Notification Appliance Circuits (NACs) rated at 2.5 amps with Synchronization for System Sensor, Wheelock, and Gentex devices.
Built-in synchronization allows conforming to present day code requirements without need for additional hardware or labor.
21
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Features and BenefitsFEATURE BENEFIT
Fully programmable from local keypad, local PS-2 keyboard or PC via PK-CD Windows® utility.
The MS-9050UD is easy to configure and is 100% programmable either locally or remotely.
Auto-programming The MS-9050UD has the capability to identify devices by detector or module type to establish fire protection across the entire facility within minutes.
22
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Features and BenefitsFEATURE BENEFIT
Programmable Sounder/Relay Base
Provides added functionality by selectively isolating notification local alarms without having to evacuate the entire building. Permits verification of actual alarm, therefore offering cost savings in equipment, labor and time.
Remote Programming and Monitoring
Permits upload/download of system programming information as well as verification of system parameters, including detector sensitivity without having to leave your office.
23
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Key ApplicationsDepartment Store Example
24
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Additional Benefits
• Why sell Addressable over Conventional?• Lower Wiring Costs• Shortened Installation Schedule• Greater Device Supervision• Superior Troubleshooting• Rapid and direct identification of the fire
threat• Simplified fire design and layout
25
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Lower wiring costs
Conventional Fire Panel
Conventional AddressableVS
MS-9050UD
26
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Shortened installation schedule
Less cabling Less conduit Less hardware Greater flexibility via software
Elevator recall HVAC shutdown Access control override
27
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Greater device supervision
Device presence Is it there or not?
Device condition Functional or not Clean vs Dirty Alarm Trouble
Type of Device Smoke detector, pull station, etc.
28
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Superior troubleshooting
Detailed trouble messages Pinpointed device location Individual walk testing Maintenance warnings
Alert Urgent Failed Automatic Test
29
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Rapid and direct identification of fire threat
Advanced notice of pending condition (pre-signal)
Detailed alarm messages Specific threat location with label
30
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Single SLC Simplifies System Design
HVAC Elevator Control
31
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
SD355
CP355
H355
D350PL
Compatible Intelligent Detectors
• AD355 Adapt Multicriteria Smoke Detector• SD355 Photoelectric Smoke Detector• SD355T Photoelectric w/Thermal• CP355 Ionization Smoke Detector• H355 Fixed Thermal Detector• H355R Fixed Thermal w/Rate-of-Rise• Separate B350LP base (with each head)• D350P Photoelectric Smoke Duct Detector• D350RP Photoelectric Smoke Duct Detector with Auxiliary
Relay
32
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
AD355 Adapt™ Multicriteria Detector
Intelligent Detectors
The intelligent fire sensor that never stops learning.
• Automatically adjusts sensitivity levels without the need for operator intervention or programming. Sensitivity increases with heat.
• Combination photo and thermal technology.
• Alarm verification
33
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Intelligent Detectors
• Rotary switches for setting address 00-99• Easy to set in field
with screwdriver• No programming tools
required• Easy to identify
address
34
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Input Modules• MMF-300 Monitor Module
• For monitoring a circuit of normally-open contact conventional alarm initiating devices
• MMF-302 Monitor Module• For monitoring 2-Wire Smoke Detectors
(requires filtered resettable 24 volts)• Can be used to retrofit conventional systems to
Addressable without costly detector replacement• MDF-300 Dual Monitor Module
• For monitoring normally-open contact alarm initiating devices.
• NFPA Style B only• Assumes two sequential addresses on the SLC
• Provides convenience for monitoring two doors or HVAC fans/dampers and other normally open contacts.
35
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Input Modules• MMF-300-10 Ten Class B
Initiating Device Circuits• MMF-302-6 Six Class B or
Three Class A Initiating Device Circuit Module for Monitoring UL Listed two-wire smoke detectors (requires filtered resettable 24 volts)• Both modules provide high
density packages for monitoring multiple devices in a small space
• Mounts in BB-2F or BB-6F backboxes
36
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Input Modules
The BB-2F will hold 2 cards (as shown).
The BB-6F w/CHS-6 will hold up to 6 cards
37
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Input Modules
• MMF-301 Mini-Monitor Module• For monitoring a single conventional,
contact-type device in the same mounting box
• NFPA Style B only• No polling LED
38
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Input Modules
• BG-12LX Addressable Pull Station• Key Resettable
• Prevents unauthorized reset
• Dual Action• Prevents accidental
activation• Polling LED viewable
through front handle• Reassures owner system
is active
39
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Output Modules
• CMF-300 NAC Control Module• NFPA Style Y (Class B)/Style Z (Class A)
• 24 VDC power must be supplied• 3-amp maximum load capability
• Permits system software control of distributed NAC power supplies
• Programmable for the following:• Auto-Silence (timed sounder cutoff)• Silence Inhibit• Silenceable vs. Non-Silenceable• Enable/Disable
40
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Output Modules
• CRF-300 Relay Control Module• Two Form-C Relays that work in unison.• Use for elevator recall, damper control, door
holding, auxiliary control functions, etc.• No tabs to break
• Easy to install• Address can be set by simply
removing front dress cover
41
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Addressable Output Modules
• CMF-300-6• Six Class B or Three Class A
Notification Appliance Circuits• High Density package for multiple
NAC control circuits
• CRF-300-6• Six Form-C Contacts
• Provides high density package for multiple relay control functions
• Mounts 2 in BB-2F or 6 in BB-6F backboxes
42
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
MS-9050UD Summary
• Ease of installation and programming• Faster setup reduces number of man hours
required per system• Individual point reporting through
communicator • provides accurate location to first responders
• Two synchronized NACs for System Sensor, Wheelock, and Gentex devices• Allows connection to different devices on
separate circuits for easier and less-costly retrofit
43
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
MS-9050UD Summary
• Three Form-C relays standard• Trouble (non-programmable)• Alarm and Supervisory are programmable
for other functions
• Programmable from internal keypad, a PS2 keyboard or a personal computer
44
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
MS-9050UD Summary
• Provides advanced maintenance and troubleshooting• Auto Detector testing
• (no special tools or tester required)• Drift Compensation
• Maintains alarm window as detector becomes dirty • Maintenance Alert
• Alerts when detectors need to be cleaned• Auto device type validation
• Immediately identifies what is connected to the panel for faster setup
45
Selling Addressable Panels
Selli
ng
ad
dre
ssab
le F
ire A
larm
Syst
em
s M
S-9
05
0U
D
Thank You