Drain pipe MUST slope away from the foundation box.
Drain pipe can connect to an existing drain pipe or be routed to a good drainage area.A deep hole filled with “good” gravel is an acceptable drainage source. Check local building codes for further information before installation.
Important:Foundation Box MUST be level and flush with driveway!
QUICKSTART “BASIC” GUIDELINES FOR MODEL 6400 - FOR A GATE UP TO 10 FEET, 300 Lbs. AND OPENING CLOCKWISE
Copyright 2021 DoorKing®, Inc. All rights reserved. 6400-066-N-1-21
Apply Grease
2 3/4”
DoorKing Heavy-Duty Hinges P/N 1200-039
Foundation Box PositionThe gate weight is NOT on the gate operator.
U-channel welded to gate arm
Gate Arm
Good Drainage
Gate hinges and operator pivot point MUST be plumb.
DriveMotor
Position
3”Post
Driveway
DriveMotor
Drive motor must be unbolted and flipped 180° to open gate
CLOCKWISE as shown.
Important Note: Operator drive motor and limit sensors are factory set to open gate COUNTER-clockwise.
LockingBracket
DriveArm
Linking Arm
Limit Plate
FoundationBox
Depth of the concrete
is determined by specific
installation requirements,
soil conditions and local
building codes.
Unlock and pull release handle from either side of the gate to manually operate the gate.
Coaxial Cable Antenna Kit
P/N 1514-073 (Sold separately)
Closed Position
Gate Arm
ReleaseHandle
Fabricated U-Channel (Not Supplied)
Gate fits into U-Channel (Not Welded)
Weld U-Channel to Gate Arm
U-channel NOT welded to gate. The gate can move in the U-channel during operation.
Oper
ator
Loop
s
Inpu
t Pow
er
Securely mount a
control box near the
operator usingappropriate hardware
(Not supplied).
Open Position
1 1/2” to Drain
Power Conduit
3/4” Sweeps1 1/2” to Drain (Not Supplied)
Loops Conduit
3”3”
3”
Drain Pipe
FoundationBox
Control Box115VAC or Solar
Model 6400 is intended for installation only on swing gates used for vehicles.Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the 6400 Actuator Arm and Control Box Mounting manual, 115 VAC or Solar Control Box Wiring/Owner’s manuals.
Plumb
120 S. Glasgow AvenueInglewood, California 90301
U.S.A.
1
78
65432
Blue wireBrown wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
Not Used
SECONDARY
Secondary operator MUST be connected to the secondary operator connection and MOTOR wires MUST be reversed from the primary operator when used.
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
7-WireOperator Cable
Single Operator connects to PRIMARY connection ONLY.
Connect to the 115 VAC OR Solar control box circuit board.
1
78
65432
PRIMARY
4302 Secondary Operator ONLY
The limit sensors must be slid 90° to open gate CLOCKWISE from factory setting.
Limit Plate
Open Close
Gray - Open (3 LED)Purple - Slow Down (4 LED)White - Common for each.
Yellow - Close (5 LED)Brown - Slow Down (6 LED)
White - Common for each.
OPENLimit Position
CLOSELimit Position
Circuit board power must be ON to adjust limit sensors, LEDs will light.
Photo Sensors Height
Open Beam
OutsideProperty
InsideProperty
5” or less
Gate
Clo
sed
CLOSE Beam
21”Typical
27.5”Max
Open Beam
Close Beam
Reversing EdgePhoto Sensor
Photo Sensor
PotentialEntrapment
Area
Gate Closed
Gate Open
DO NOT cycle operator before limit sensors andDIP-switches have been adjusted, damage could occur.
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.dkslocator.com to find a professional installing and servicing dealer in your area.
Installation
Same Drive MotorOrientation
Open Open
Closed
Open Open
ClosedSame Drive Motor
Orientation
Opening Direction DIP-Switch 1 (SW 1)
Refer to YOUR chosen 115 VAC OR Solar powered control box manuals for complete DIP-switch settings.
4302
4302
Manually move the gate to the desired open or closed position. Loosen the limit nuts and slowly slide the limit assemblies until the LIMIT LEDs on the circuit board light up.
Limit Sensors Adjustment
ManualKey Release
Reversing Edge is mounted
along ENTIRE end of gate.
4302
Wiring to Circuit Board
Note: Only 1 monitored Device can be connected for each cycling direction. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices.Refer to YOUR chosen 115 VAC OR Solar powered control box manuals to wire entrapment protection devices.
Opens as Shown
Opens as Shown
The operator MUST OPEN GATE upon initial power up and OPEN command.If the operator closes gate after giving open command, shut off power and reverse this switch setting otherwise operator will NOT function correctly.
ExternalEntrapmentProtection
DevicesEntrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will not run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.
UL 325 August2018 Standard
Switch 1 OFF
Switch 1 OFF
Switch 1 ON
Switch 1 ON
Note: If factory wired jumpers are on operator terminal, they MUST be removed.
SW 1
1 ON2
34
56