1 quick disconnect power distribution. 2 power distribution methods hardwiring o traditional method...

36
1 Quick Disconnect Power Distribution

Upload: augusta-sullivan

Post on 20-Jan-2016

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

1

Quick Disconnect Power Distribution

Page 2: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

2

Power Distribution Methods

• Hardwiringo Traditional method for providing power to machines and deviceso Difficult and time consuming methodo Other options exist

• Quick Disconnecto Typically thought of for control circuitso In 2002 NFPA 79 gave approval for the use of Q.D. connectors for powero Becoming more and more accepted in many different industries

Page 3: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

3

powerfast – Overview

• What is TURCK powerfast?oAny industrial TURCK circular style connector that has capability to run at 15

amps or higher

• What TURCK products are categorized as powerfast?oM16 Power (up to 18 amps)oM23 Power (up to 30 amps)oM40 Power (up to 40 amps)oNew product – 7/8” A-Size Power (up to 15 amps)oNew product – 1 3/8” D-Size Power (up to 30 amps)

Page 4: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

4

Applications

• Devices• Motors• Lights• Heaters• Other electrical devices

• Industries• Conveying• Machine builders• Food and beverage• Automation system designers and integrators• Sorting machines• Packaging and palletizing• Automotive• Solar

Page 5: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

5

powerfast – Benefits

• Common challenges how to power the system?

• Hardwiringo Incurs high costs from excessive professional electrical time and labor costso Difficulties of working around obstacles and routing conduit and electrical wiring o Requires the need to “reinvent the wheel” on installations

Page 6: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

6

powerfast – Benefits

• TURCK’s powerfast eliminates the need for conduit and hardwiringoEliminates the need for toolsoEliminates threading, pipe bending, and wire pullingoEliminates need for a certified electrician

Page 7: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

powerfast – Benefits

• Quick disconnect connectorsoModular wiring solutionoRobust and reliableoEliminates concern for mis-wiringoEliminates the need to “reinvent the wheel”

7

Page 8: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

powerfast – Benefits

• Cost SavingsoQuick system assembly and commissioningoReduction in labor and installation costsoEliminate down timeoEasy maintenance, replacement, and change out

8

Page 9: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

9

powerfast – Benefits

• Scalable and modular topologyoAbility to meet custom needsoMore flexibilityoFaster commissioningoExpandable

Page 10: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

10

powerfast – Power Distribution Topology

Page 11: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

11

powerfast – Power Distribution Topology

Page 12: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

M16 Powerfast

12

TURCK powerfast

High amperage connector in a compact, rugged, molded body

Page 13: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

13

M16 powerfast

• Cordsets, receptacles, and tees

o2 – 4 pin

o12 &14 AWG conductors

oRated to 15-18 Amps, 600 VAC/VDC

oNickel-plated brass or stainless steel hardware

o IEC IP67 protection

oUL/cUL approvals

Page 14: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

• Cordsets

oStraight and right angle available

oTray rated, exposed run PVC flexlife cable

oShielded versions available

14

M16 powerfast

• Receptacles

oFront mount and rear mount threads available

o½”-14 NPT, 3/8”-18NPT, M18 and M20 mounting threads

Page 15: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

• TeesoVarious configuration optionsoAvailable with QD or cable for both trunk and drop

15

M16 powerfast

Page 16: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

16

M16 powerfast

• Small ‘h’ and big ‘H’ style teesoAvailable with customizable QD or cable brancheso Ideal for installing right in cable tray

Page 17: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

M16 powerfast

17

• Field Wireableso 2 – 4 pinoAccepts 8-11mm cable diameters

• PowerlokoCovers connection pointoNot required, but a good safeguard

• Closure capsoPrevent dust or moisture when disconnectedoAvailable with or without lanyard

Page 18: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

A-Size Powerfast

18

TURCK powerfast

Higher amperage industry standard 7/8” minifast® connector

Page 19: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

19

A-Size (7/8”) powerfast

• Cordsets and receptacles

o3 and 4-pin

o14 AWG conductors

oRated to 15 Amps, 600 VAC/VDC

oNickel-plated brass or stainless steel hardware

o IEC IP67 protection

oUL/cUL approvals pending

Page 20: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

20

A-Size (7/8”) powerfast

• Cordsets

oStraight and right angle available

oTray rated, exposed run PVC flexlife cable

oAvailable with or without STOOW cable rating

• Receptacles

oFront mount threads

o½”-14 NPT mounting threads

Page 21: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

21

A-Size (7/8”) powerfast

• PowerlokoCovers connection pointoNot required, but a good safeguard

•Closure capsoPrevent dust or moisture when disconnectedoAvailable with or without lanyard

Page 22: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

D-Size Powerfast

22

TURCK powerfast

Ideal for complete power distribution system

Page 23: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

23

D-Size powerfast

• Cordsets, receptacles, and teeso3-pin

10 AWG 30 amps 12 AWG 25 amps 14 AWG 18 amps

oNickel-plated brass, aluminum, or stainless steel hardwareoProvides IEC IP67, 68, 69K and NEMA 1,3,4,6P protectionoUL/cUL approvals

o4-pin 10 AWG 25 amps 12 AWG 20 amps 14 AWG 15 amps

Page 24: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

24

powerfast – hp Ratings

• Estimated hp ratings

Page 25: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

25

D-Size powerfast

• Cordsets

oStraight and right angle available

oTray rated, exposed run PVC flexlife cable

oAvailable with or without STOOW cable rating

• Receptacles

oFront mount threads

o½”-14 NPT and ¾”-14 NPT mounting threads

Page 26: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

26

D-Size powerfast

• Tees and reducer teesoAvailable with integral D-Size Power dropsoAvailable with D-Size Power, A-Size Power, and M16 Power cable drops

• Field Wireableso Field installable connectorso Accepts 8-14 AWG conductorso Accepts 9-26mm cable diameters

Page 27: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

27

D-Size powerfast

• Power ReducersoD-Size Power to A-Size or M16 Power connectorsoEliminates need for reducer tee at end of lineoProvides a cost savings

Page 28: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

28

D-Size powerfast

• PowerlokoCovers connection pointoNot required, but a good safeguard

• Closure capsoPrevent dust or moisture when disconnectedoAvailable with or without lanyard

Page 29: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

What’s New?

• D-Size integral power drop teesoD-Size Power to A-Size or M16 Power connectorsoConnector drop right off of the teeoProvides a cost savingsoExample p/n: GSDM/GKDM/RKM 44

•D-Size Small ‘h’ splitteroAvailable with customizable QD or cable brancheso Ideal for installing right in cable trayoAdd “SH-” to beginning of tee part number

29

Page 30: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

• QD disconnect switchesoAvailable with 3 or 4 pole A-Size Power connectorsoAdditional auxiliary versions available with M12 connector

30

What’s New?

Page 31: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

M23 Powerfast

31

TURCK powerfast

Combination of power and signal wires in one cable

Page 32: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

• Cordsets and receptacles

o6 – 9 pin

o12 – 14 AWG conductors for power, 18 AWG conductors for signal

oNickel-plated brass or stainless steel hardware

oRated up to 30 Amps, 600 VAC/VDC

o IEC IP67 protection

32

M23 powerfast

Page 33: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

• Cordsets

oStraight and right angle

oTray rated, exposed run PVC flexlife cable

oShielded versions available

33

M23 powerfast

• Receptacles

oFront mount threads

oM20 and flange mount mounting threads

Page 34: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

34

powerfast – Summary

• Eliminate conduitoReplace with quick disconnect connectors

• Cost savingsoHigher cost upfrontoLong term cost savings can be realizedoUp to an estimated 40% cost savingsoSavings in labor and reduction of downtime

• ProductsoMultiple products to chose fromoFind the right product for the applicationo2-3 week standard lead time

Page 35: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

35

powerfast Brochure

• Covers TURCK’s complete line of powerfast products• Includes useful application and technical notes• Brochure # B2300

Page 36: 1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult

• TURCK powerfast – Power that delivers!

• Questions?

36