KULIAH RADIOLOGI
-
RADIOLOGI
RADIODIAGNOSTIKPENGGUNAAN SINAR X YNG DIHASILKAN TABUNG RONGSEN UNTUK MENEGAKAN DIAGNOSE PENYAKIT
RADIO TERAPIBIDANG RADIOLOGI YANG MENGGUNAKAN SINAR X,GAMMA, & BETA ELEKTRON UNTUK MEMBUNUH SEL TUMOR GANAS
KEDOKTERAN NUKLIRBIDANG RADIOLOGI YANG MENGGUNAKAN RADIO ISOTOP UNTUK DIAGNOSIS DAN TERAPI
RADIO FISIKABIDANG RADIOLOGI YANG BEHUBUNGAN DENGAN FISIKA RADIASI UNTUK PENGEMBANGAN RADIO TERAPI DAN RADIO PROTEKSI
-
RADIOLOGIFISIKA RADIOLOGI (RADIO FISIKA)RADIOGRAFI
-
PROSES TERJADITEORINYAPERALATANKEPENTINGAN UNTUK KEDOKTERAN
-
FISIKA RADIOLOGI
DASAR-DASAR FISIKA RADIASIMATERI & RADIASIKONSEP ATOM NIELS BOHR DAN RUTHERFORD
-
DASAR-DASAR FISIKA RADIASI
NIELS BOHR & RUTHERFORD
SUATU ATOM TERDIRI DARI INTI YANG BERMUATAN POSITIP, DIKELILINGI ELEKTRON DAN BERMUATAN NEGATIP
DALAM INTI TERDAPAT PARTIKEL PROTON YANG BERMUATAN POSITIP DAN NEUTRON YANG TIDAK BERMUATAN LISTRIK (NETRAL)
JUMLAH PROTON DALAM INTI ATOM ADALAH SAMA DENGAN JUMLAH ELEKTRON YANG MENGELILINGI KECUALI ATOM HIDROGEN (H), HANYA PUNYA 1 PROTON DAN 1 ELEKTRON (TIDAK PUNYA NEUTRON)
JUMLAH PROTON DAN NEUTRON SUATU ATOM MENUNJUKAN BERAT ATOM
JUMLAH PROTON DAN ELEKTRON SUATU ATOM MENUNJUKAN NOMOR ATOM
ELEKTRON YANG MENGELILINGI INTI ATOM MEMPUNYAI GARIS EDAR / LAPISAN TERTENTU, DAN SETIAP LAPISAN DITEMPATI SEJUMLAH ELEKTRON TERTENTU PULA
-
IONISASI
RADIASI YAITU PEMANCARAN TENAGA SECARA DIVERGEN DARI SUATU SUMBER KESEKITARNYA MENURUT GARIS LURUSSEBAGIAN RADIASI BILA MENGENAI SUATU MATERI AKAN MENYEBABKAN IONISASI DALAM MATERI TERSEBUT
IONISASIPEMBENTUKAN SEPASANG ION POSITIP & ION NEGATIPION POSITIP : ATOM / MOLEKUL YANG KEKURANGAN ELEKTRONION NEGATIP : ATOM / MOLEKUL YANG KELEBIHAN ELEKTRON
KEMAMPUAN TIMBULKAN IONISASI DIGUNAKAN DALAM RADIODIAGNOSTIK KHUSUSNYA FOTOGRAFI DAN RADIO TERAFI
-
INTERAKSI RADIASI DENGAN MATERI
ENERSI ABSORBSI :
BILA SINAR X / GAMMA MENGENAI SUATU BENDA / TUBUH MANUSIA TERJADI PEMINDAHAN ENERGI RADIASI KE DALAM JARINGAN TUBUH
RADIASI TERSEBUT MENGALAMI PERLEMAHAN / ATENUASI ATAU ENERSINYA BERKURANG
PROSES ENERSI ABSORBSIABSORBSI FOTO ELEKTRIKEFFEK COMPTONPEMBENTUKAN SEPASANG ION
-
RADIASI PENG-ION (SINAR PENG-ION)
ADALAH RADIASI YANG DITIMBULKAN IONISASI DALAM SUATU MATERI
MACAM SINAR PENGION
SINAR / RADIASI ELEKTROMAGNETIK
DISEBUT JUGA DENGAN SINAR RADIASI NON-KORPUSKULAR YAITU SINAR DENGAN PANJANG GELOMBANG YANG SANGAT PENDEK
SINAR X : BERASAL DDARI PESAWAT / GENERATORSINAR GAMMA : BERSAL DARI BAHAN RADIOAKTIF ATAU RADIOISOTOPSINAR KOSMIA : BERASAL DARI BINTANG DIALAM RAYA,SINAR INI MEMPUNYAI PANJANG GELOMBANG YANG AMAT PENDEK SEHINGGA DAYA TEMBUSNYA AMAT DALAM.
-
SINAR ELEKTROMAGNETIK YANG BUKAN SINAR PENGION
SINAR INFRA RED
SINAR ULTRAVIOLET
SINAR YANG TERLIHAT (VISIBLE LIGHT)
GELOMBANG RADIO
TIDAK SEMUA SINAR ELEKTROMAGNETIK MENYEBABKAN IONISASI
-
B. SINAR KORPUSKULER ( RADIASI KORPUSKULER )
SINAR INI MEMPUNYAI DAYA TEMBUS KECIL
PEMANCARAN TENAGA MELALUI SUATU MATERI
SINAR INI DIBAGI :
BERMUATAN LISTRIKSINAR ELEKTRON (BETA)SINAR PROTON,DEUTRON & ALFHA
TIDAK BERMUATAN LISTRIKSINAR NEUTRON
DIBIDANG RADIO TERAFI MENGGUNAKAN SINAR GAMMA, SIAR X DAN SINAR BETA
-
ENERGI RADIASI & KWALITAS RADIASI
RADIASI MEMPUNYAI ENERSI ,E (erg) = H X N
N = C / LAMBDA
E = H X C / LAMBDA
NB = E : ENERGI DALAM erg / DETIK H : CONSTATNTA PLANK (6.62 X 10-27 erg / DETIK) n : FREKUENSI RADIASI C : PANJANG GELOMBANG (3 X 10 ,10 CM / DETIK)
ENERGI RADIASI BERBANDING TERBALIK TERBALIK DENGAN PANJANG GELOMBANG
MAKINPENDEK PANJANG GELOMBANG MAKIN BESAR ENERSINYA
-
KWALITAS RADIASI
HOMOGENITAS DARI RADIASI
SINAR YANG DIHASILKAN PESAWAT RONGSEN PANJANG GELOMBANGNYA BERBEDA-BEDA.
SINAR YANG DIHASILKAN BAHAN RADIOAKTIF / RADIOISOTOP PANJANG GELOMBANG HAMPIR SAMA (LEBIH HOMOGEN DARI SINAR X)
SCACTER ( SINAR HAMBUR)
SINAR PRIMER BILA MENGENAI SUATU BAHAN AKAN DIBELOKAN ARAHNYA.
SINAR YANG BERUBAH ARAH DARI SINAR PRIMERR DISEBUT (SINAR HAMBHUR)
-
SINAR X
DITEMUKAN 8 NOPEMBER 1985 OLEH PROF WILHEM KONRAD RONTGEN
SINAR RONTGEN / SINAR X
DASAR-DASAR ALAT SINAR X
SUMBER ELEKTRON YAITU KATODA BERMUATAN NEGATIP
GAYA UNTUK MEMPERCEPAT GERAKAN ELEKTRON YAITU KUTUB KATODA DI BERIKAN TEGANGAN TINGGI
RUANG HAMKPA UDARA ANTARA KATODA & ANODA DALAM TABUNG RNTGEN
ALAT PEMUSAT BERKAS ELEKTRON
PENGHENTI ELEKTRON YAITU ANODA
-
PROSES TERJADINYA SINAR X
BILA ADA ALIRAN LISTRIK TERJADI LONCATAN ELEKTRON DARI KATODA KE ANODA,DAN GERAK
AN INI DIPERCEPAT DENGAN MEMBERIKAN TEGANGAN TINGGI ANTARA KATODA DAN ANODA
ELEKTRON DENGAN KECEPATAN TINGGI MEMBENTUR ANODA DAN ENERGI BENTURAN 99% MENJADI PANAS DAN 1 % MENJADI SINAR X
DIFOKUSKAN MELALUI PINTU / LUBANG
SIAP DI GUNAKAN
-
SIPAT SINAR X
DAYA TEMBUS
ATTENUASI (PERLEMAHAN,PENGURANGAN,PENYERPAN)
RADIASI SEKUNDER (PERTEBARAN)
FOTOGRAFIS
LUMINISCENT (PENDAR FLUORESENSI DAN PHOSPORESENSI
IONISASI
EFFEK BIOLOGIS
-
DAYA TEMBUS
SIFAT SALING PENTING UNTUK TUJUAN DIAGNOSIS DAN TERAPI
DIPENGARUHI OLEH
ENERSI SINAR X : - TERGANTUNG KV - KV TINGGI PANJANG GELOMBANG PENDEK DAYA TEMBUS TINGGI
KONSENTRASE / DENSITAS /OBJEK YANG DITEMBUS MAKIN BANYAK SINAR KENAI OBJEK MAKIN HITAM GAMBARAN FILM
NOMOR ATOM NOMOR ATOM TINGGI MAKIN RENDAH DAYA TEMBUS
TEBAL OBJEK
-
2. ATTENUASI (PENYERAPAN / PERLEMAHAN
SINAR X DISERAP ATAU MENGALAMI PERLEMAHAN SEWAKTU MENEMBUS BAHAN PADAT
TERGANTUNG DARI BERAT ATOM & NOMOR ATOM
MAKIN TINGGI KEPADATAN & BERAT ATOM MAKA MAKIN BESAR PENYERAPAN
-
3. RADIASI SEKUNDER / PERTEBARAN
SINAR X BILA MELALUI BAHAN BERKAS SINAR X BERTEBARAN TIMBULKAN RADIASI SEKUNDER / HAMBUR GAMBAR FILM KABUR
UNTUK MENGATASI RADIASI HAMBUR DI TARUH GRID ANTARA SUBJEK DAN FILM
-
4. EFEK FOTOGRAFIK
SINAR X MENGHITAMKAN EMULSI FILM (EMULSI FERAK BROMIDA)
SETELAH DIPROSES SECARA KIMIAWI (DIBANGKITKAN) DI KAMAR GELAP
-
5. PENDAR PLUROSENSI
SINAR X DISEBABKAN
KALSIUM TUNGSTAT
ZINK SULFIDA
MEMENDARKAN CAHAYA (LUMINI SENSI)
LUMINISENSI ADA 2 :
FLUOROSENSI : MEMENDARKAN CAHAY SEWAKTU ADA RADIASI SINAR X SAJA
FOSFORISENSI : PEMENDARAN CAHAYA BERLANGSUNG BEBERAPA SAAT WALAUPUN RADIASI SINAR X SUDAH DIMATIKAN
-
6. IONISASI
SINAR X AKAN TIMBULKAN IONISASI PARTIKEL BAHAN / ZAT YANG DILALUI
UNTUK : DIAGNOSTIK & TERAFI
7. EFEK BIOLOGIK
SINAR X MENYEBABKAN PERUBAHAN BIOLOGIK JARINGAN SEHINGGA DI GUNAKAN UNTUK RADIO TERAFI
-
SUMBER UTAMA RADIASI
BAHAN RADIO AKTIF (RADIO ACTIVE NUCLIDES)
ALAT PENGHASIL SINAR X
-
ALAT PENCATAT DOSIS PERSONIL
FILM BADGE : MENCATAT DOSIS RADIASI
DOSIMETER SAKU - PENGATUR DOSIS - LEBIH TELITI DARI FILM BADGE
ALAT PENGUKUR RADIASI
GEIGER MULLER SURVEY METER (MR / JAM)ATAU COUNT /MENIT MENGUKUR PEMAPARAN DITEMPAT TEMPAT :
PERSONIL BEKERJA
DINDING LUAR RUANG SINAR X
PINTU
JENDELA KACA
2. MENGUKUR ALAT-ALAT PROTEKSI
-
SATUAN RADIASI
R : RONTGEN
RAD : RONTGEN ABSORBED DOSE
REM : RONTGEN EQUIVALENT MAN
RONTGEN
SATUAN PEMAPARAN RADIASI YANG MEMBERIKAN MUATAN (2,58 X10-4) COULOUMB/Kg UDARA
-
2. RAD
SATUAN DOSIS SERAP
1 RAD = RADIASI YANG DIPERLUKAN UNTUK MELEPASKAN TENAGA 100 ERG DALAM 1 GR BAHAN YANG DISINAR (1 RAD = 100ERG / Gr
0.K. EFEK RADIASI TERHADAP JARINGAN TERGANTUNG BESARNYA ENERGI YANG DISERAP MAKA SATUAN RAD DIGUNAKAN DALAM RADIO TERAFI
HUBUNGAN R & RAD
R UNTUK MENENTUKAN BANYAKNYA SINAR X DI UDARA
RAD : UNTUK MENGUKUR BANYAKNYA SINAR X YANG DISERAP
GRAY (GY)
1 GRAY = 100RAD
-
3.REMSATUAN DOSIS EKUIVALENREM = DOSIS SERAP X FACTOR KUALITAS MERUPAKAN UKURAN EFFEK BIOLOGIS AKIBAT RADIASI1 RONTGEN = 1 RAD = 1 REM
FACTOR KUALITASJENIS RADIASIFKSINAR X1SINAR GAMMA 1PARTIKEL BETA1PROTON5NEUTRON LAMBAT3NEUTRON CEPAT10PARTIKEL ALFA20
EFFEK BIOLOGIS 1 RAD SINAR PROTON > 10 X DARI PADA EFFEK BIOLOGIS 1 RAD SINAR X / GAMMA
SIVERT (SV)1 SV = 100 REM
-
RADIOGRAFI
JENIS PEMERIKSAAN SINAR X
PEMERIKSAAN SINAR TEMBUS (FLUOROSKOPI / DOOR LICHTING)
PEMERIKSAAN FOTO RONTGEN (RADIOGRAFI)
-
PEMERIKSAAN SINAR TEMBUS
PEMERIKSAAN SECARA LANGSUNG ORGAN-ORGAN TUBUH YANG BERGERAK
RADIASI PADA PENDERITA / PEMERIKSA TINGGI
TANPA FILM (DOKUMENTASI -) TIDAK BOLEH DI GUNAKAN LAGI
SEKARANG MENGGUNAKAN IMAGE INTENSIFIER (+ KAMERA TV)RADIASI SEDIKITTANPA MENGGELAPKAN RUANGAN
-
RADIOGRAFI
PERLENGKAPAN MEMBUAT RADIOGRAFI
JENIS PEMERIKSAAN DAN POSISI
PENGETAHUAN PESAWAT RONTGEN
PENGETAHUAN KAMAR GELAP
PROSES TERJADINYA GAMBARAN RADIOGRAFI
-
PERLENGKAKAPAN
FILM RONTGEN
INTENSIFYING SCREEN
KASET
GRID
ALAT FIKSASI
ALAT PELINDUNG
MARKER
-
FILM RONTGEN
LAPISAN
KARAKTERISTIK
JENIS FILM :
SCREEN FILM
PAKAI INTENSIFIYING SCREEN (IS)
N0N-SCREEN
TANPA IS
FILM GIGI MAMOGRAFI
SENSITIFITAS
BLUE SENSITIFITAS
GREEN SENSITIFITAS
-
INTENSIFIYING SCREEN
MENAMBAH EFEK SINAR X SEHINGGA MEMPERPENDEK MASA PENYINARAN ( DOSIS RADIASI
-
KASET
KASET SINAR X
TEMPAT FILM RONTGEN
BERISI 2 IS
HARUS DIJAGA
JANGAN JATUH
BAHAN-BAHAN KIMIA
HARUS KERING
TIDAK BOLEH TERBUKA
TIDAK BOLEH DITUMPUK
JANGAN ADA BAGIAN YANG RUSAK
-
GRID (KISI-KISI)
UNTUK MENGURANGI RADIASI HAMBUR AGAR TIDAK SAMPAI KE FILM RONTGEN
JENIS :
GRID DIAM (STASIONARY GRID / LISHOLM)
GRID BERGERAK (MOVING GRID / BUCKY)
CARA PENGGUNAAN GRID
TIDAK BOLEH TERBALIK
JARAK FOCUS FILM (FFD) HARUS TEPAT
FACTOR EXSPOSISI DI NAIKAN
-
5. ALAT FIKSASIAGAR OBJEK TIDAK BERGERAKBANTAL PASIR / SPONSIKAT PINGGANG / PENEKANKLEM KEPALA
6. ALAT-ALAT PELINDUNGDIAPHRAGMA CAHAYAKONUSPELINDUNG GONAD / OVARIUMAPRON TIMBALSARUNG TANGAN TIMBALPENCEGAH PELINDUNG / TIRAI PB (PROTECTIVE SHIELDINGKACA TIMBAL / KARET TIMBALKACA MATA (PB)
7. MARKER TANDA KANAN (R) DAN KIRI (L)
-
2. JENIS PEMERIKSAAN
A. PEMERIKSAAN RONTGEN DASAR (TANPA BAHAN KONTRAS)THORAXKEPALAABDOMENTULANG BELAKANGEXSTREMITAS
B. PEMERIKSAAN RONTGEN DENGAN OBAT / BAHAN KONTRASSALURAN CERNASALURAN KENCINGC. PEMERIKSAAN RONTGEN KHUSUSARTERIOGRAFIANGIKARDIOGRAFIFLEBOGRAFI,DLL
-
POSISI
PENDERITA DIANTARA TABUNG RONTGEN DAN FILMPENDERITA SEDEKAT MUNGKIN DENGAN FILMMACAM-MACAM POSISS
ANTERO-POSTERIORPOSTERO-ANTERIORLATERALDECUBITUSOBLIQUEDLL
-
POSISI POSTERO-ANTERIORARAH SINAR X DARI BELAKANG PENDERITA FILM / KASET DI TARUH DI DEPAN PENDERITAPENDERITA BERDIRI TEGAK
POSISI ANTERO-POSTERIORARAH SINAR X DARI DEPAN PENDERITA FILM / KASET DI TARUH DI BELAKANG PENDERITA PENDERITA SUPINFE / TIDURAN
POSISI LATERALINSPIRASIKELAINAN DIDALAM / DILUAR PARUTV,KULITBENDA-BENDA DIKULITOTOT PECTORIS MAYORRAMBUT / SANGGUL dll
-
TOP LORDOTIK APAPEK PARUPENDERITA BERSANDAR MIRING PADA KASET FILM & SINAR DARI DEPAN
LEFT ATAU RIGHT LATERAL DECUBITUS (LLD/RLD)CCAIRAN DALAM CAVUM PLEURA
TOMOGRAM / PLANIGRAMALAT-ALAT RONTGEN KHUSUSTUMOR PARU,dll
-
PENGETAHUAN ALAT RONTGENFACTOR EXPOSEFACTOR JARAK
-
FACTOR EKSPOSI
TERGANTUNGTEBAL OBJEKPAKAI GRID / TIDAKOBJEK YANG BERGERAK : ANAK KECIL WAKTU EKSPOSI SESINGKAT MUNGKIN
TERDIRI ATAS :A. KILO VOLTAGE (KV) KV : DAYA TEMBUS > : DAYA TEMBUS BESAR < : DAYA TEMBUS KECIL (KUALITAS RADIASI)B. MILIAMPERE SECONDS (MAS) : KUANTITAS RADIASI MAS = MA X S CONTOH : = MAS: MA X S 100 X 1/60 DETIK PEMERIKSAAN ORGAN BERGERAK : MA TURUN
-
2. JARAK
a. JARAK FOCUS KE FILM FOCUS FILM DISTANCE (FFD)b. JARAK OBJEK KE FILM OBJEK FILM DISTANCE (OFD)c. JARAK FOCUS KE OBJEK FOCUS OBJEK DISTANCE (FOD)
FFD > OFD TETAP = GAMBAR MENDEKATI BESAR ASLINYAOFD > FOD TETAP = GAMBAR DIPERBESARFOD = OFD GAMBAR DIPERBESAR 2 XOBJEK TAK SEJAJAR FILM DISTORSIOBJEK SEJAJAR FILM ARAH SINAR MENYUDUT DISTORSIPEMERIKSAAN FOCUS KECIL = GAMBAR TAJAMPEMERIKSAAN FOCUS BESAR JARAK DIPERKECIL GAMBAR KURANG TAJAM
-
KAMAR GELAPUKURANMENURUT KAPASITAS & BEBAN KERJATIDAK < 4 M2TERLINDUNG DARI RADIASI & SINAR LAINSIRKULASI DAN SUHU UDARA BAIK (16-20 DERAJAT CELCIUS)AIR BASAHDINDING & LANTAI TAHAN KEROPOSKELENGKAPAN MEMADAISAFE LIGHT AMAN & TIDAK BOCOR
DAERAH BASAHBAK AIR MENGALIRTANKI DEVELOPER & FIXERDAERAH KERINGTEMPAT FILM,KASET, HANGER dll
-
PROSES PENCUCIAN & PENGOLAHAN FILM RONTGEN
A. MANUAL FILM DIDALAM KASET KAMAR GELAP FILM HANGERCAIRAN PEMBNGKIT (DEVELOPER)BAK BERISISI AIR (PEMBILAS)CAIRAN PENETAP (FIXER)BAK AIR MENGALIRPENGERINGAN
B. AUTOMATIC (MESIN PENCUCI / PROCESOR)
-
PROSES TERJADINYA GAMBAR RADIOGRAFI
GAMBARAN LATENOBJEK DENGAN KERAPATAN TINGGI > (SINAR X) IS MEMENDDARKAN FLUORESENSI SEDIKIT SEKALI/TIDAK > PERAK HALOGEN SEDIKITNYA MENGALAMI PERUBAHANOBJEK DENGAN KERAPATAN RENDAH > (SINAR X) FLUOROSENSI TINGGI > PERUBAHAN PERAK HALOGEN
B. GAMBARAN TAMPAKGAMBARAN LATENOBJEK DENGAN KERAPATAN TINGGI > DEVELOPER > RADIO OPAKOBJEK DENGAN KERAPATAN RENDAH > DEVELOPER > RADIO LUSCENT
-
RADIO LUSENT & RADIO OPAK
SINAR X
DAYA TEMBUS BERBEDA-BEDA
MUDAH TEMBUS- RADIO LUSENT
SUKAR TEMBUS RADIO OPAK
-
1. RADIO LUSENT (HITAM)UDARA GAS
2RADIO LUSENT SEDANGLEMAK
3.KEPUTIH-PUTIHANJAR IKAT KARTILAGO,OTOTDARAH,BATU KOLESTEROL & URAT
4.RADIO OPAQUE SEDANGTULANG & GARAM CALSIUM
5.RADIO OPAQUE PUTIHLOGAM