NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 1 -
NITIN CORPORATION 402, 4
th Floor,
Bezzola Commercial Complex,
Sion – Trombay Road,
Chembur,
Mumbai – 400071,
India.
WEB : www.corponit.com E – MAIL : [email protected]
FAX : +91 - 22 - 25235386
PH (O) : +91 - 22 - 25234478/67973677
1 No. 6 MW Thermodyne/ Belliss (2000) make,
Bagasse fired Complete Power Plant
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 2 -
BOILER DETAILS:
Make : Thermodyne Technologies
P. Ltd Ranipet – 632406
Year : 2000
Heating Surface : 1856M2
Super Heater Outlet Temp. 440oC. Coil type primary &
secondary super heaters – 158.0M2
Economiser : Coil type economizer – 387.2M2
Air Heater : 1200M2 – Heating Surface
F.D. Fan : 14.5M3/Sec., 230 MM of water
I.D. Fan : 32.4M3/Sec., 300 mm of water
S.A. Fan : 4.3M3/Sec., 770 mm of water
Feed water storage tank: 60M3
Deareater with tank : 60M3
Feed Pumps : 2 Nos. , Type HAD 65/11, Make:KSB
D.M. Plant : Capacity-360M3/Day, 15 T/Hr.
Single tank – 75M3 storage
TURBINE DETAILS:
Make : BELLISS INDIA LTD
Type : HEN -22
Inlet Pressure : 44 Kg/Cm2
Progressive No. : BM/4557/B
Output : 6000 kW (BHP)
Year : 2000
Inlet Temp. : 420oC.
Exhaust Pressure : Vacuum at 0.12 ATA
Speed : 8500 RPM
Extraction Pressure : 7 Kg/Cm2 (Bleed)
Bleed/Extraction Qty.: 11.0 TPH
Quantity of steam sent to condenser – 24 to 30 TPH
GEAR BOX DETAILS:
Make : TRIVENI ENGG. & IND.LTD. MYSORE
S.No. : 00023
Model No. : 0560x, Gear Ratio – 5.76
Year : 2000; Power – 6000 kW
Input speed : 8600 RPM
Output speed : 1500 RPM
Type : Double Helical
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 3 -
No.of teeth : 164/29, Service factor – 1.7
Oil : 46 or 68 No.
ALTERNATOR DETAILS:
Make : Toyo Denki Japan – by Kirloskar Elec.Co.Ltd
Year : 2000
Speed : 1500 RPM
Cooling Arrangement :Air cooled – air is cooled by cooling Tower water Circulation.
NOTE :
The Boiler is using bagasse as fuel. The Boiler has dumping type furnace grate. From
bagasse yard, bagasse is shifted with the help of belt conveyor. In between bail breaker is
installed. Then bagasse goes to boiler through R.B.C. (Rear Bagasse Carrier) & bagasse
elevator. Finally, bagasse is fired to the boiler with pneumatic bagasse spreader, i.e. with
the help of S.A. Air pressure.
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 4 -
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 5 -
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 6 -
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 7 -
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 8 -
NITIN CORPORATION 1 No. 6 MW Complete Power Plant
MUMBAI.
- 9 -