1 ltw series 2 wire loop testers. 2 two wire loop testers two wire loop testing objective of the...

12
1 LTW series 2 wire loop testers

Upload: eunice-gaines

Post on 27-Dec-2015

220 views

Category:

Documents


1 download

TRANSCRIPT

1

LTW series 2 wire loop testers

2

Two wire loop testers

Two wire loop testing

Objective of the instrument range:

• Two wire Non-tripping loop impedance measurement

• Improvement on existing loop test performance

• Extended operational voltage range

• New high resolution option

3

Two wire loop testers

LTW300 series loop testers

LTW315 replaces the LT310 No-trip 2 wire testing

2 wire fast test

CATIV 300V applications

0.01ohms resolution

100V to 280V loop testing

Auto test start

PFC Calculation

Backlit display

4

Two wire loop testers

LTW300 series loop testers

LTW325 replaces the LT320

Additional features over LTW315

50V centre tap testing

440V Phase to Phase testing

MaxZ – Maximum loop value

R1+R2 measurement

5

Two wire loop testers

LTW300 series loop testers

LTW335 replaces the LT330

Additional features over the LTW325

300 test result storage

• Job, db, ct, Ph etc

Result recall to screen

Downloading via USB

6

Two wire loop testers

LTW300 series loop testers

LTW425 new high resolution range

High resolution loop tester

No trip testing to 0.01ohms

0.001 resolution on high current test

Extended PFC calculation (40KA)

7

Two wire loop testers

LTW Benefits

All instruments: Direct replacements for the LT300 series

2 wire measurements on all loop tests

No tripping of RCDs

Automatic test extension on noise detection

50V to 440V loop measurement on all test modes

AUTO start on contact loop test

High resolution loop test (LTW425)

• Greater confidence in loop result

• Increased PSCC and PFC calculation range

CATII, III and IV, 300V applications

8

Two wire loop testers

Selling against the competition

Key sales point• Two wire NO-TRIP loop test

– Simple connection

– Radial circuits as easy as rings

– Safer testing – no loose leads

• CATIV applications– Used outside the premise

• 50V to 440V operation– Centre tap 110V applications (even RCD protected)

• Advanced noise detection system– Test extension and noise warning

9

Two wire loop testers

Selling against the competition

Additional sales points• High resolution 0.001ohm resolution• Extended PFC range to 40KA• R1+R2 and MaxZ measurements• Voltage and frequency measurement• Automatic voltage display• Large clear backlit display

• IP54 weatherproof case• Calibration certificate included • 3 year warranty

LTW425 display

10

Two wire loop testers

Product availability

Engineering product field trials continuing Pre-production run August 2006 Field trial units September 2006 FPS End September 2006 Product launch Beginning October 2006

LT to LTW product transfer

LT and LTW to run concurrently for 6 months

Sales teams to focus on transferring distributors and enquiries to new LTW

11

Two wire loop testers

Sales tools

Product launch document

Datasheets

Pricing/discount structure

Broad competitor comparison spreadsheet

Colour LTW single fold A4 brochure

A5 leaflet

Counter mats

Head -to- head comparisons

Simple old new conversion chart

Loop testing & CATIV applications guides

Presentation

12

Two wire loop testersEND