1 | inala technologies ecs-l testing : version 1.0

15
1 | INALA TECHNOLOGIES ECS-L TESTING : VERSION 1.0

Upload: jemima-hudson

Post on 02-Jan-2016

238 views

Category:

Documents


9 download

TRANSCRIPT

1 |

INALA TECHNOLOGIESECS-L TESTING :

VERSION 1.0

2 |

ECS-L TEST – FLOW CHART

ECS-L Test Preparation

• Insert SIM in to MODEM•Connect SAM1.5 to ECS-L• Inter Connect the 2 RS232 Ports of ECS-L

• Inter connect 2 RS485 Ports of ECS-L

•Power up ECS-L with or without SAM1.5

ECS-L Test Set-up •Configure ECS-L with

test Configuration•Configure Test Server IP address.

ECS-L Test with Server

•Server Auto detects communication from new ECS-L unit and IP Address

•Server runs test scrip to check the following:

•ECS-L Serial Number•Communication between the 2 RS232 ports

•Communication between the 2 RS485 ports

•Generate and email a PDF test certificate to predefined list of email addresses. If test was successful or not and ECS-L is working correctly or not.

•Configure ECS-L with Vodacom Config

If test is unsuccessful and ECS-L is not working a test certificate will be issued

indicating the part of the test that failed

Print out Test Certificate and Power Down

unit and Package with

Test Certificate

Do fault FindingRepair faultRepeat process Te

st

Fail

Test

Pa

ss

3 | SAM Training

ECS-L - COMMUNICATION CONNECTIONS

ECS Software Management Platform

RS232 test cable

RS232 SAM1.5

GPRS to Management Platform

RS485 Test Cable

RS232 Test cableUse Staight RS232 Ribbon Cable – IDC 10way to IDC 10 Way.

Plug into Port3 DTE and Port5 DCE

RS485 Test CableWirePort1 TX to Port4 TXPort1 RX to Port4 RXPort1 GND to Port4 GND

4 | SAM Training

ECS-L – PHYSICAL PORT NUMBERS

PORT 5 - RS232 (ECT)

PORT 3 - RS232

PORT 1 – RS485

PORT 2 - RS232

PORT 4 - RS485

5 | SAM Training

SOFTWARE FOR ECS-L (CONFIG TO BE LOADED BEFORE TEST)

Communication Controller Software (ECT):Current Version ECT – V2.28ECT Version is viewed on the top left corner as indicated with the yellow circleEG: “ITMS-C Ver 2.28”

Current Version Firmware – V2024Firmware Version is viewed on the button left corner as indicated with the Red circleEG: “S/W: 2.0.2.4”

IP address is automatically allocated to sim card and is displayed.

Input APN name “vodameter” and Server IP 10.85.71.146

6 | SAM Training

SOFTWARE FOR ECS-L (CONFIG TO BE LOADED AFTER TEST)

Communication Controller Software (ECT):Current Version ECT – V2.28ECT Version is viewed on the top left corner as indicated with the yellow circleEG: “ITMS-C Ver 2.28”

Current Version Firmware – V2024Firmware Version is viewed on the button left corner as indicated with the Red circleEG: “S/W: 2.0.2.4”

IP address is automatically allocated to sim card and is displayed.

Input APN name “vodameter” and Server IP 1.1.1.1

7 |

ECS-L2 - COMMUNICATION CONNECTIONS

SAM TrainingECS Software Management Platform

RS232 test cable

RS232 SAM1.5

GPRS to Management Platform

RS485 Test Cable

RS232 Test cableUse Staight RS232 Ribbon Cable – IDC 10way to IDC 10 Way.

Plug into Port3 DTE and Port5 DCE

RS485 Test CableWirePort1 TX to Port4 TXPort1 RX to Port4 RXPort1 GND to Port4 GND

8 | SAM Training

ECS-L2 – PHYSICAL PORT NUMBERS

PORT 5 - RS232

PORT 2 – Isolated RS485

PORT 4 – RS232

PORT 3 - RS232

PORT 1 - RS485* The physical port that is

connected to the SAM must be selected as the “Event PORT”

USB PORT – ECS2 ECT Port

12VDC Power GND+12vdc

9 |

ECS(ETH/GPRS - COMMUNICATION CONNECTIONS

SAM TrainingECS Software Management Platform

RS232 test cable

RS232 SAM1.5

GPRS to Management Platform

RS485 Test Cable

RS232 Test cableUse Staight RS232 Ribbon Cable – IDC 10way to IDC 10 Way.

Plug into Port3 DTE and Port5 DCE

RS485 Test CableWirePort1 TX to Port4 TXPort1 RX to Port4 RXPort1 GND to Port4 GND

10 | SAM Training

ECS(ETH/GPRS – PHYSICAL PORT NUMBERS

PORT 1 – RS485

PORT 2 – Isolated RS485

PORT 3 – RS232

PORT 4 – RS232

PORT 5 – RS232

PORT 6 – RS232

PORT 7 – RS232

* The physical port that is connected to the SAM or Access Control must be selected

as the “UDP PORT”

11 | SAM Training

ECS(ETH/GPRS) & ECS-L(GPRS) CONFIG TO BE LOADED BEFORE TEST

Communication Controller Software (ECS2 ECT):Current Version ECT – V1.4 ECT Version is viewed on the top left corner as indicated with the yellow circleEG: “ECS2 ECT V 1.4”

Current Version Firmware – V1.4Firmware Version is viewed on the bottom as indicated with the Red circleEG: “Build: 1.4”

IP address is automatically allocated to sim card and is displayed.Enable:1. GPRS Modem2. Input APN name “vodameter”3. UDP Server - 10.85.71.1464. Input Regional Server IP for applicable

region and UDP port “299”5. Set Port configuration6. Click on Update unit7. Wait for unit to complete updating

12 | SAM Training

ECS(ETH/GPRS) & ECS-L(GPRS) CONFIG TO BE LOADED AFTER TEST

Communication Controller Software (ECS2 ECT):Current Version ECT – V1.4 ECT Version is viewed on the top left corner as indicated with the yellow circleEG: “ECS2 ECT V 1.4”

Current Version Firmware – V1.4 Firmware Version is viewed on the bottom as indicated with the Red circleEG: “Build: 1.4”

IP address is automatically allocated to sim card and is displayed.Enable:1. GPRS Modem2. Input APN name “vodameter”3. VPN Server - 1.1.1.14. Input Regional Server IP for applicable

region and UDP port “299”5. Set Port configuration6. Click on Update unit7. Wait for unit to complete updating

13 | SAM Training

HOW TO TEST SAM COMMUNICATION

Pre Test Instructions::1. Make sure Communication cable is

connected between communication controller and SAM.

2. Make sure communication cable is connected between PC and communication controller

3. Make sure PC IP address is within range of the communication controller – only applicable with the ECS(E1/Ethernet) communication controller.

Open the SAM ECT4. Select TCP5. Insert the IP address of the communication

controller6. Insert the applicable port number, usually

301 or 3107. Click on OK and communication will

commence.

NOTE: If this is a SAM2 unit not running on V3.03 firmware it will be necessary to log into the SAM2 unit using an RS232 cable to enable “RS485” on the SAM2 unit.

14 | SAM Training

HOW TO TEST ACCESS CONTROL COMMUNICATION

Pre Test Instructions::1. Make sure Communication cable is

connected between communication controller and the Access Controll.

2. Make sure communication cable is connected between PC and communication controller

3. Make sure PC IP address is within range of the communication controller – only applicable with the ECS(E1/Ethernet) communication controller.

Open the Access Control ECT4. Select TCP5. Insert the IP address of the communication

controller6. Port Number is set to 301 as a default7. Click on Connect and the Logon and

communication will commence Test.8. Click on “Open Door” 9. Click on “Get Version10. Click on “Get Time”11. Click on “Log off”

15 |

CLICK TO EDIT MASTER TITLE STYLE

THANK YOU