® *Also available in: Pencil Rib and Flat Pan. SEAMING DETAILS TREMLOCK VP 1.5” & 2” CURVED *Also available in: Pencil Rib (2” only) and Flat Pan (2” only). TREMLOCK VP 90° FOLD BEFORE SEAMING 2” 2.083” 2” STRIATED (STD.) 12”, 16” or 18” MINOR RIB (STD.) 3” 18” or 24” 3.083” 1.496” 12”, 16” or 18” 1.535” TREMLOCK VP 2” & 3” SEAMING DETAILS TREMLOCK VP 1.5” & 2” 180° FOLD TREMLOCK VP 1.5” & 2” BEFORE SEAMING 2” 2.083” 2” STRIATED (STD.) 12”, 16” or 18” 1.5” STRIATED (STD.) NOTE: Oil canning is a natural occurance in metal panels and is not a cause for panel rejection. TREMLOCK VP TREMLOCK VP 1.5’ & 2” can also be curved. Composition and Material: TremLock VP Roof System is a factory roll formed metal roof system that is manufactured from 24 or 22 gauge Galvalume, an aluminum-zinc alloy meeting ASTM A792, Class AZ-50. Galvalume carries a 25 year warranty against perforation, rupture and structural failure due to exposure to normal Environmental conditions. The galvanized panel is coated with Kynar 500 / Hylar 5000. Rib sealant is installed at the factory to ensure water tightness. Basic Use: The TremLock VP Metal Roof System can be specified as a new or retrofit system for Architectural application on roof slope minimum 1/2” on 12” for 2” high panels, 1/4” on 12” for 3” high panels. Its versatile structural standing seam design and aesthetically pleasing appearance make it suitable for almost any roof configuration and complex geometrics. They are capable of spanning secondary structural members spaced up to five feet and can be applied to light gauge steel framing or 5/8” minimum plywood decks. System Design: TremLock VP Roof System is designed with a 2” or 3” leg height that requires mechanical field seaming. TremLock VP Roof System can be installed over a wide variety of substrates capable of spanning secondary structural members spaced up to five feet and can be applied to light gauge steel framing, 5/8” minimum plywood decks, metal deck and rigid insulation. When using TremLock VP in a radius application an underlayment must be applied to the substrate using a minimum 30-pound felt or rubberized asphaltic membrane. Application Data: Refer to TremLock VP Installation manual. Finish and Color: TremLock VP Roof System will be coated both sides with a full strength, 70% Kynar 500 / Hylar 5000 fluoropolymer coating system of 1.0 mil (.025mm) total dry film thickness. Underside, 0.3 – 0.4 mil dry film thickness. AVAILABILITY AND COST: Contact your local Tremco Roofing Representative for pricing and availability. For the name and number of your local representative, call the Roofing Division at 216/292-5000. MAINTENANCE: Your local Tremco Roofing Representative can provide you with effective maintenance procedures, which may vary depending upon specific conditions. Periodic inspections, early repairs and preventive maintenance are all part of a sound roof program. TECHNICAL SERVICES: Your local Tremco Representative, working with the Technical Service staff, can help analyze conditions and needs to develop recommendations for special applications. The services of the Tremco Research Center, which has earned a unique reputation in weatherproofing technology, complement and extend the services of the Tremco Technical Service Staff. ROOFING & BUILDING MAINTENANCE

Upload: lequynh

Post on 19-Apr-2018

227 views

Category:

Documents


2 download

TRANSCRIPT

®

*Also available in: Pencil Rib and Flat Pan.

SEAMING DETAILSTREMLOCK VP 1.5” & 2” CURVED

*Also available in: Pencil Rib (2” only) and Flat Pan (2” only).

TREMLOCK VP90° FOLD

BEFORE SEAMING2” 2.083”2” STRIATED (STD.)

12”, 16” or 18”

MINOR RIB (STD.)3”

18” or 24”

3.083”

1.496”

12”, 16” or 18”

1.535”

TREMLOCK VP 2” & 3” SEAMING DETAILS

TREMLOCK VP 1.5” & 2”180° FOLD

TREMLOCK VP 1.5” & 2”BEFORE SEAMING

2” 2.083”2” STRIATED (STD.)

12”, 16” or 18”

1.5” STRIATED (STD.)

NOTE: Oil canning is a natural occurance in metal panels and is not a cause for panel rejection.

TREMLOCK VP TREMLOCK VP 1.5’ & 2” can also

be curved.

Composition and Material: TremLock VP Roof System is a factory roll formed metal roof system that is manufactured from 24 or 22 gauge Galvalume, an aluminum-zinc alloy meeting ASTM A792, Class AZ-50. Galvalume carries a 25 year warranty against perforation, rupture and structural failure due to exposure to normal Environmental conditions. The galvanized panel is coated with Kynar 500 / Hylar 5000. Rib sealant is installed at the factory to ensure water tightness. Basic Use: The TremLock VP Metal Roof System can be specified as a new or retrofit system for Architectural application on roof slope minimum 1/2” on 12” for 2” high panels, 1/4” on 12” for 3” high panels. Its versatile structural standing seam design and aesthetically pleasing appearance make it suitable for almost any roof configuration and complex geometrics. They are capable of spanning secondary structural members spaced up to five feet and can be applied to light gauge steel framing or 5/8” minimum plywood decks.

System Design: TremLock VP Roof System is designed with a 2” or 3” leg height that requires mechanical field seaming. TremLock VP Roof System can be installed over a wide variety of substrates capable of spanning secondary structural members spaced up to five feet and can be applied to light gauge steel framing, 5/8” minimum plywood decks, metal deck and rigid insulation. When using TremLock VP in a radius application an underlayment must be applied to the substrate using a minimum 30-pound felt or rubberized asphaltic membrane.

Application Data: Refer to TremLock VP Installation manual.

Finish and Color: TremLock VP Roof System will be coated both sides with a full strength, 70% Kynar 500 / Hylar 5000 fluoropolymer coating system of 1.0 mil (.025mm) total dry film thickness. Underside, 0.3 – 0.4 mil dry film thickness.

AVAILABILITY AND COST: Contact your local Tremco Roofing Representative for pricing and availability. For the name and number of your local representative, call the Roofing Division at 216/292-5000.

MAINTENANCE: Your local Tremco Roofing Representative can provide you with effective maintenance procedures, which may vary depending upon specific conditions. Periodic inspections, early repairs and preventive maintenance are all part of a sound roof program.

TECHNICAL SERVICES: Your local Tremco Representative, working with the Technical Service staff, can help analyze conditions and needs to develop recommendations for special applications. The services of the Tremco Research Center, which has earned a unique reputation in weatherproofing technology, complement and extend the services of the Tremco Technical Service Staff.

ROOFING & BUILDING MAINTENANCE

NOTES:1. Allowable uniform loads are based upon equal span lengths and are calculated in accordance with sound engineering principles and practices using the given section properties.2. Wind Load is wind suction or uplift and is based upon ASTM E 1592 test data using a factor of safety of 1.65.3. Wind Load has been increased by 33 1/3%. (Note: Increase is not allowed on military projects.)4. Live Load is the allowable Live or Snow load.5. De�ection loads are limited by a maximum de�ection of L/180 or the maximum bending stress whichever is less.6. The weight of the panel has not been deducted from the allowable loads.7. Web crippling has not been checked for the allowable loads shown above.

3

T R E M L O C K V P 2 1 6 L O A D T A B L E

DEFLECTIONA L L O WA B L E L O A D S ( P S F ) *

LIVE LOADNEGATIVE WIND LOAD

5 0

5 0

F YK S I

2 4

2 2

G a . 3 . 5 4 4 . 5 5 3 4 5 6 3 4 5 6

3

T R E M L O C K V P 2 1 8 L O A D T A B L EA L L O WA B L E L O A D S ( P S F ) *

LIVE LOADNEGATIVE WIND LOAD

5 0

5 0

F YK S I

2 4

2 2

G a . 3 . 5 4 4 . 5 5 3 4 5 6 3 4 5 6

3

T R E M L O C K V P 3 2 4 L O A D T A B L E A L L O WA B L E L O A D S ( P S F ) *

LIVE LOADNEGATIVE WIND LOAD

5 0

F YK S I

2 4

G a . 3 . 5 4 4 . 5 5 3 4 5 6 3 4 5 6

T E S T DATA N OT AVA I L A B L E

9 6 . 2 2 8 7 . 2 2 7 8 . 8 8 7 1 . 1 7 6 4 . 1 1 2 7 7 . 1 0 1 5 5 . 9 0 9 9 . 8 0 6 9 . 3 0 2 7 7 . 1 0 1 5 5 . 9 0 9 9 . 8 0 6 9 . 3 0

1 1 6 . 5 9 1 0 7 . 6 5 9 9 . 2 5 9 1 . 3 8 8 4 . 0 4 3 0 8 . 7 0 1 7 3 . 6 0 1 1 1 . 1 0 7 7 . 2 0 3 0 8 . 7 0 1 7 3 . 6 0 1 1 1 . 1 0 7 7 . 2 0

9 7 . 6 2 8 6 . 2 5 7 6 . 1 6 6 7 . 3 8 5 9 . 9 0 2 4 6 . 4 0 1 3 8 . 6 0 8 8 . 7 0 6 1 . 6 0 2 4 6 . 4 0 1 3 8 . 6 0 8 8 . 7 0 6 1 . 6 0

1 2 6 . 9 0 1 1 5 . 9 8 1 0 5 . 8 9 9 6 . 6 5 8 8 . 2 4 3 4 7 . 2 0 1 9 5 . 3 0 1 2 5 . 0 0 8 6 . 8 0 3 4 7 . 2 0 1 9 5 . 3 0 1 2 5 . 0 0 8 6 . 8 0

3 6 1 . 7 0 2 0 3 . 5 0 1 3 0 . 2 0 9 0 . 4 0 3 6 1 . 7 0 2 0 3 . 5 0 1 3 0 . 2 0 9 0 . 4 0

DEFLECTION

DEFLECTION

5 02 2 6 8 0 . 4 0 3 8 2 . 7 0 2 4 4 . 9 0 1 7 0 . 1 0 6 8 0 . 4 0 3 8 2 . 7 0 2 4 4 . 9 0 1 7 0 . 1 0

16”

G a u g e F y ( k s i ) W t . ( p s f ) T h i c k ( i n c h ) I x ( i n 4 ) S x ( i n 3 ) F b ( k s i ) I x ( i n 4 ) S x ( i n 3 ) F b ( k s i )P a n e l To p i n C o m p r e s s i o n P a n e l B o t t o m i n C o m p r e s s i o n

T R E M L O C K V P 2 1 6 S E C T I O N P R O P E R T I E S

2 4 5 0 1 . 3 6 0 0 . 0 2 3 0 . 2 1 3 2 0 . 1 2 2 9 2 9 . 9 0 . 1 2 1 7 0 . 1 0 6 7 2 9 . 9

NOTE: Section properties are calculated in accordance with 1986 AISI Speci�cations. Sx and Fb are for stress determination;Ix is for de�ection determination.

2 2 5 0 1 . 6 9 4 0 . 0 3 0 0 . 2 7 3 1 0 . 1 5 9 3 2 9 . 9 0 . 1 5 7 3 0 . 1 3 3 7 2 9 . 9

2” 2 1/16”

18”

G a u g e F y ( k s i ) W t . ( p s f ) T h i c k ( i n c h ) I x ( i n 4 ) S x ( i n 3 ) F b ( k s i ) I x ( i n 4 ) S x ( i n 3 ) F b ( k s i )P a n e l To p i n C o m p r e s s i o n P a n e l B o t t o m i n C o m p r e s s i o n

T R E M L O C K V P 2 1 8 S E C T I O N P R O P E R T I E S

2 4 5 0 1 . 3 1 7 0 . 0 2 3 0 . 1 9 3 3 0 . 1 0 8 9 2 9 . 9 0 . 1 0 8 2 0 . 0 9 4 9 2 9 . 9

NOTE: Section properties are calculated in accordance with 1986 AISI Speci�cations. Sx and Fb are for stress determination;Ix is for de�ection determination.

2 2 5 0 1 . 6 4 2 0 . 0 3 0 . 2 4 8 3 0 . 1 4 1 7 2 9 . 9 0 . 1 3 9 9 0 . 1 1 8 9 2 9 . 9

3” 3 1/16”

24”

G a u g e F y ( k s i ) W t . ( p s f ) T h i c k ( i n c h ) I x ( i n 4 ) S x ( i n 3 ) F b ( k s i ) I x ( i n 4 ) S x ( i n 3 ) F b ( k s i )P a n e l To p i n C o m p r e s s i o n P a n e l B o t t o m i n C o m p r e s s i o n

T R E M L O C K V P 3 2 4 S E C T I O N P R O P E R T I E S

2 4 5 0 1 . 3 2 9 0 . 0 2 3 0 . 3 3 6 0 0 . 1 2 4 6 2 9 . 9 0 . 3 0 0 8 0 . 1 3 9 4 2 9 . 9

NOTE: Section properties are calculated in accordance with 1986 AISI Speci�cations. Sx and Fb are for stress determination;Ix is for de�ection determination.

2 2 5 0 1 . 6 5 7 0 . 0 3 0 . 4 3 5 9 0 . 2 4 5 3 2 9 . 9 0 . 3 8 8 1 0 . 2 6 2 1 2 9 . 9

2” 2 1/16”

GUARANTEE/WARRANTY: Tremco Incorporated warrants TremLock VP metal roof system to be free of defects and to meet published physical properties when tested according to ASTM and Tremco standards. Under warranty, any TremLock VP product that is proved to be defective when applied in accordance to our written instructions, and in applications recommended by Tremco as suitable for this product will be replaced with like product at no charge. THIS IS BUYER’S SOLE AND EXCLUSIVE REMEDY.

All claims concerning product defects must be made in writing within twelve (12) months of shipment. The absence of such claims in writing during this period will constitute a waiver of all claims with respect to such product. This warranty shall be IN LIEU of any other warranty, express or implied, including but not limited to, any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

STATEMENT OF POLICY AND RESPONSIBILITY: Tremco takes responsibility for furnishing quality materials and for providing specifications and recommendations for their proper installation. As neither Tremco itself nor its Representatives practice architecture or engineering, Tremco offers no opinion on, expressly disclaims any responsibility for the soundness of any structure on which its products may be applied. If questions arise as to the soundness of a structure or its ability to support a planned installation properly, the Owner should obtain the opinion of competent structural engineers before proceeding. Tremco accepts no liability for any structural failure or for the resultant damages, and no Tremco Representative is authorized to vary this disclaimer.

Kynar 500 is aregistered trademark of Elf Autochem North America, Inc. Hylar 5000 is a registered trademark of Ausimont USA, Inc. TremLock is a registered trademark of Tremco Incorporated

3735 Green Road Beachwood, OH 44122 216-292-5000

220 Wicksteed Ave Toronto, ONT M4H 1G7 416-421-3300

REV. 1/11

ROOFING & BUILDING MAINTENANCE