1 3 tcs room rest osed · 16 inspection form 15 17 14 11 12 select rinse. select “r” on the...

2
Transport Cleaning System – Restroom Cleaning Provided by: Pro-Link, Inc. Telephone: 800-74-LINKS www.prolinkhq.com Copyright © Pro-Link, Inc. 07.10 / version 1.0 PL-104 TCS Directions Before using the TCS for the first time, become familiar with the nozzle and the control panel. The nozzle has two settings: The “S” setting is used when a chemical is selected. It will allow the chemical to spray with low pressure. The “R” setting is used when the rinse is selected. It will allow water to spray at a moderate pressure. 2 7 3 1 5 6 9 4 8 Gather equipment. Place “Restroom Closed” sign at the door. Dust mop or sweep floor. Wear proper personal protective equipment. Fill the water tank as needed. Turn the TCS on. Select the appropriate cleaner. Select “S” on the nozzle. Select the appropriate cleaner. Select S” on the nozzle. Spray fixtures. Spot scrub heavy soils or graffiti. Spray again. Clean both sides of the entrance doors with a disinfectant cleaner. Refill supplies and clean all dispensers. 10 Remove trash, clean trash cans and replace liners. Spray inside and outside of toilet or urinal. Spray partition from bottom to top. Wipe partition with a squeegee. Repeat for each area. CLOSED REST ROOM TCS Transport Cleaning System Turn to change selection

Upload: others

Post on 19-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 3 TCS ROOM REST OSED · 16 Inspection Form 15 17 14 11 12 Select rinse. Select “R” on the nozzle. Rinse the toilets and partitions. With rinse and "R" still selected, rinse

Transport Cleaning System – Restroom Cleaning

Provided by:

Pro-Link, Inc. Telephone: 800-74-LINKS www.prolinkhq.com

Copyright © Pro-Link, Inc. 07.10 / version 1.0 PL-104

TCS DirectionsBefore using the TCS for thefirst time, become familiarwith the nozzle and the control panel.

The nozzle has two settings:

The “S” setting is usedwhen a chemical is selected.It will allow the chemical tospray with low pressure.

The “R” setting is usedwhen the rinse is selected.It will allow water to sprayat a moderate pressure.

2

7

31

5

6

9

4

8

Gather equipment. Place “Restroom Closed” sign at the door.

Dust mop or sweep floor. Wear proper personal protective equipment.

Fill the water tank as needed. Turn the TCS on. Select the appropriate cleaner. Select “S” on the nozzle.

Select the appropriate cleaner. Select “S” on the nozzle. Spray fixtures. Spot scrub heavy soils or graffiti. Spray again.

Clean both sides of the entrance doors with a disinfectant cleaner.

Refill supplies and clean all dispensers.

10

Remove trash, clean trash cans and replace liners.

Spray inside and outside of toilet or urinal. Spray partition from bottom to top. Wipe partition with a squeegee. Repeat for each area.

CLOSED

RESTROOMTCS

Transport CleaningSystem

Turn to change selection

Page 2: 1 3 TCS ROOM REST OSED · 16 Inspection Form 15 17 14 11 12 Select rinse. Select “R” on the nozzle. Rinse the toilets and partitions. With rinse and "R" still selected, rinse

16

InspectionForm

15

17

14

121211

Select rinse. Select “R” on the nozzle. Rinse the toilets and partitions.

With rinse and "R" still selected, rinse fixtures. Flush toilets and urinals. Wipe as needed.

Select the appropriate cleaner. Select “S” on the nozzle. Spray floors.

Turn the TCS off. Point the nozzle toward the floor and pull the trigger to empty the hose.

Squeegee floors toward the drain or pick up solution with a microfiber mop.

Inspect your work and report any repairs as needed.

Plug in the battery charger at the end of the shift.

13 Cleaner

Cleaner

Rinse

Green Cleaning Tips

● Use properly diluted products, preferablythrough a dispensing system like theTransport Cleaning System.

● Make sure all spray bottles are properlylabeled.

● Never mix cleaning products together.

● Periodically machine-scrub restroom floorswith a disinfectant.

● Make sure appropriate dwell times for disinfectants are followed.

● Use microfiber cloths when possible, and use color-coded cloths by area.

= Green Cleaning Process

TCS Control PanelSettings

The control panel is wherethe chemical or rinse isselected. Simply turn thechemical select valve in thedirection of the desiredoutput. The chemical selectvalve will point to the itemselected.

Note: At the end of eachshift it is important to perform a clear water rinseof the system. Simply turnthe chemical select valve to rinse and spray for 5 seconds. This will prolongthe life of the pump.

Optional equipment includes:● Battery Meter● Foam Gun● Start-up Kit

Troubleshooting Guide

Restroom Problem Product to Use

Discolored Grout TranZyme or TransOxy

Graffiti ProOrange Concentrate or RTU

Hair Spray Streak Free Glass Cleaner

Hard Water Deposits TransOxy, TranZyme or TransAll

Mold and Mildew TransOxy

Rust PhosClean

Soap Scum TransOxy, TranZyme or TransAll

Urine and Odors TranZyme, Broadband Q256 or TransOxy

Pro-Link, Inc. Telephone: 800-74-LINKS www.prolinkhq.com

Copyright © Pro-Link, Inc. 07.10 / version 1.0 PL-104

osniel.t
Typewritten text
East Continental Supplies 7955 W 20 Avenue Hialeah, FL 33014 Office: 305.887.0158 Toll Free: 888.513.2929 Fax: 305.887.0186 www.ecsupplies.com