Exterior Masonry
Cladding Repairs
Williamson County
Historic Courthouse710 Main Street
Georgetown, Texas 78626
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
512.257.4800 tel | 512.219.9883 fax
Headquarters & Laboratories : Northbrook, Illinois
Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit
Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
MATERIAL SCIENTISTSWJE
Austin, Texas 78717
9511 N. Lake Creek Parkway
ARCHITECTS
ENGINEERS
Texas Registered Engineering Firm F-0093
Cop
yri
ght
201
5.
All
rig
hts
res
erved
. N
o p
art
of
this
do
cum
ent
may
be
rep
rod
uce
d i
n a
ny
fo
rm o
r b
y a
ny
mea
ns
wit
hout
per
mis
sio
n f
rom
Wis
s, J
ann
ey,
Els
tner
Ass
oci
ates
, In
c. (
WJE
). W
JE d
iscl
aim
s an
y r
esponsi
bil
ity f
or
its
unau
thori
zed u
se.
No. DATE DESCRIPTION
WJE PROJECT No.:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJ. MANAGER:
SCALE:
2013.0373.0
May 18, 2015
DMC / LMM
ELB / SWF
CJL
AS NOTED
SHEET TITLE:
SHEET No.:
WJE SEAL:
PROJECT:
CLIENT:
Williamson County
Purchasing Department301 SE Inner Loop, Suite 106
Georgetown, Texas 78626
THIS DOCUMENT IS RELEASED FOR PRICINGPURPOSES ONLY UNDER THE AUTHORITY OF:
CARL J. LAROSCHE, P.E.(TEXAS P.E. No. 91870)
MAY 18, 2015
NOT FOR
CONSTRUCTION
PRELIMINARY
PRICING SUBMITTAL
Cover Sheet
& Index
S1.0
S1.0 COVER SHEET & INDEX
S1.1 GENERAL NOTES & INFORMATION
S2.0 REPAIR ELEVATION KEY PLAN
EXTERIOR ELEVATIONS: NORTH REPAIRS
DESCRIPTIONNo.
DRAWING SHEET INDEX
S3.2
S3.3
S4.0
S4.4 SECTIONS & DETAILS
SECTIONS & DETAILS
EXTERIOR ELEVATIONS: WEST REPAIRS
EXTERIOR ELEVATIONS: SOUTH REPAIRSS3.0
S3.1 EXTERIOR ELEVATIONS: EAST REPAIRS
Consulting Engineer:
Wiss, Janney, Elstner Associates, Inc.9511 N. Lake Creek ParkwayAustin, Texas 78717PH: (512) 257-4800 / FAX: (512) 219-9883TEXAS REGISTERED ENGINEERING FIRM F-0093
WJE
EXTERIOR MASONRY CLADDING REPAIRS
Project Location:
Williamson CountyHistoric Courthouse
710 Main StreetGeorgetown, Texas 78626
CONTACT: Mr. Dale Butler | PH: (512) 943-1609
S2.1 2ND FLOOR PORTICO REPAIR PLANS
S4.1 SECTIONS & DETAILS
S4.2 SECTIONS & DETAILS
S1.2 SITE COORDINATION PLAN
S4.3 SECTIONS & DETAILS
05-18-2015 REVISED DRAWING SHEET INDEX1
1
1
PROJECT LOCATION:
HISTORIC WILLIAMSON
COUNTY COURTHOUSE
710 Main Street
Georgetown, Texas
Exterior Masonry
Cladding Repairs
Williamson County
Historic Courthouse710 Main Street
Georgetown, Texas 78626
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
512.257.4800 tel | 512.219.9883 fax
Headquarters & Laboratories : Northbrook, Illinois
Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit
Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
MATERIAL SCIENTISTSWJE
Austin, Texas 78717
9511 N. Lake Creek Parkway
ARCHITECTS
ENGINEERS
Texas Registered Engineering Firm F-0093
Cop
yri
ght
201
5.
All
rig
hts
res
erved
. N
o p
art
of
this
do
cum
ent
may
be
rep
rod
uce
d i
n a
ny
fo
rm o
r b
y a
ny
mea
ns
wit
hout
per
mis
sio
n f
rom
Wis
s, J
ann
ey,
Els
tner
Ass
oci
ates
, In
c. (
WJE
). W
JE d
iscl
aim
s an
y r
esponsi
bil
ity f
or
its
unau
thori
zed u
se.
No. DATE DESCRIPTION
WJE PROJECT No.:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJ. MANAGER:
SCALE:
2013.0373.0
May 18, 2015
DMC / LMM
ELB / SWF
CJL
AS NOTED
SHEET TITLE:
SHEET No.:
WJE SEAL:
PROJECT:
CLIENT:
Williamson County
Purchasing Department301 SE Inner Loop, Suite 106
Georgetown, Texas 78626
THIS DOCUMENT IS RELEASED FOR PRICINGPURPOSES ONLY UNDER THE AUTHORITY OF:
CARL J. LAROSCHE, P.E.(TEXAS P.E. No. 91870)
MAY 18, 2015
NOT FOR
CONSTRUCTION
PRELIMINARY
PRICING SUBMITTAL
General Notes
& Information
S1.1
& AND
A.F.F. ABOVE FINISH FLOOR
ADD'L. ADDITIONAL(LY)
APPROX. APPROXIMATE
ARCH. ARCHITECT
ARCH'L ARCHITECTURAL
A/C AIR CONDITIONER
B.F.F. BELOW FINISH FLOOR
B.O. BOTTOM OF ......
B.O.B. " " " " BEAM
B.O.C. " " " " CONCRETE
B.O.F. " " " " FOOTING
B.O.S. " " " " SLAB
B.O.W. " " " " WALL
C CENTERLINE
C STEEL CHANNEL SECTION
CONC. CONCRETE
CMU CONCRETE MASONRY UNIT
CONT. CONTINUOUS
CONST. CONSTRUCTION
C.J. CONSTRUCTION JOINT
d PENNY (NAIL SIZE)
DL DEAD LOAD
DIAG. DIAGONAL
DIA. DIAMETER
DIM(S). DIMENSION(S)
DS DOWN SPOUT
DWG(S). DRAWING(S)
DBL. DOUBLE
DN DOWN
EA. EACH
E.F. EACH FACE
E.W. EACH WAY
EL. or ELEV. ELEVATION
ELEC. ELECTRIC(AL)
EQ. EQUAL
EQUIP. EQUIPMENT
EXP. EXPANSION
EXT. EXTERIOR
F.F. FINISH FLOOR
FD FLOOR DRAIN
F.V. FIELD VERIFY
GA. GAGE OR GAUGE
GALV. GALVANIZED
GWB GYPSUM WALL BOARD
H.D. HOT-DIPPED
HSA HEADED STUD ANCHOR
HSS HOLLOW STEEL SECTION
HORIZ. HORIZONTAL
INFO. INFORMATION
INT. INTERIOR
INTERM. INTERMEDIATE
K KIPS (1000 lbs.)
KLF KIPS PER LINEAR FOOT
KSF KIPS PER SQUARE FOOT
LL LIVE LOAD
LLV LONG LEG VERTICAL
LSL LONG SLOTTED HOLE
MFR. MANUFACTURE(D)(R)
MAX. MAXIMUM
MECH. MECHANICAL(LY)
MIN. MINIMUM
MISC. MISCELLANEOUS
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. or # NUMBER
O.C. ON CENTER
O.H. or OPP. OPPOSITE HAND
OSB ORIENTED STRAND BOARD
OVS OVERSIZED HOLE
P PLATE
PERP. PERPENDICULAR
PLF POUNDS PER LINEAR FOOT
P.T. PRESERVATIVE TREATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
R RADIUS
REINF. REINFORCE(D) (MENT) (ING)
REQ'D. REQUIRED
RD ROOF DRAIN
SCHED. SCHEDULE(D)
SIM. SIMILAR(LY)
SPEC(S). SPECIFICATION(S)
SPEC'D. SPECIFIED
SF SQUARE FEET
S.S. STAINLESS STEEL
SSL SHORT SLOTTED HOLE
STD. STANDARD
STRUCT'L. STRUCTURAL
T&G TONGUE AND GROOVE
TEMP. TEMPORAR(Y) (ILY)
T.O. TOP OF ......
T.O.B. " " " " BEAM
T.O.C. " " " " CONCRETE
T.O.F.F. " " " " FINISH FLOOR
T.O.F. " " " " FOOTING
T.O.P. " " " " PIER
T.O.S. " " " " SLAB
T.O.S.C. " " " " STRUCT'L. CONCRETE
T.O.W. " " " " WALL
TS STRUCTURAL STEEL TUBING
TYP. TYPICAL(LY)
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
W WIDE FLANGE BEAM
WWF WELDED WIRE FABRIC
W/ WITH
L
L
PROJECT ABBREVIATIONSGENERAL NOTES
SCOPE OF PROJECT
1. THE DRAWINGS AND SPECIFICATIONS APPLY TO THE WILLIAMSON COUTNY COURTHOUSE
(710 MAIN STREET, GEORGETOWN, TEXAS) ONLY AND SHALL NOT BE USED FOR ANY OTHER
PURPOSE WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE WISS, JANNEY, ELSTNER
ASSOCIATES, INC.
2. THE DRAWINGS AND SPECIFICATION ARE TO BE TAKEN IN THEIR ENTIRETY AND AS A
WHOLE. IF A DISCREPANCY IS FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING, AND THE ENGINEER SHALL HAVE
THE OPTION AS TO WHICH GOVERNS.
3. THE SCOPE OF WORK IS DEFINED BY THE CONTRACT DRAWINGS AND SPECIFICATIONS,
INCLUDES ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED TO ACCOMPLISH THE
WORK. IN GENERAL, THE SCOPE OF WORK INCLUDES:
A. REPOINTING AT AREAS OF DETERIORATED MORTAR BETWEEN BRICK MASONRY,
CAST STONE, AND TERRA COTTA UNITS.
B. REPAIR OF CRACKS IN CAST STONE AND TERRA COTTA.
C. PATCHING OF DAMAGED AND SPALLED BRICK MASONRY, CAST STONE, AND TERRA
COTTA UNITS. PATCHED AREAS ARE TO MATCH EXISTING IN COLOR AND
AESTHETIC QUALITY.
D. REPAIR OF EXPOSED TERRA COTTA ANCHORAGE AT TOP OF PILASTERS,
INCLUDING REMOVAL OF GROUT FROM ANCHORAGE POCKETS, CLEANING AND
COATING OF ANCHORAGE, AND INSTALLATION OF NEW GROUT MATERIAL WITH
PROTECTIVE COATING.
E. SURFACE CLEANING OF BRICK MASONRY, CAST STONE, AND TERRA COTTA
CLADDING COMPONENTS WITH CLEANING MATERIALS AS SPECIFIED.
F. REMOVAL AND REPLACEMENT OF SEALANT AND BACKING MATERIALS AT
PERIMETER JOINTS OF ALL WOOD-FRAMED WINDOWS AND DOORS.
G. REMOVAL OF CORROSION FROM STEEL LINTELS, INCLUDING CLEANING, PRIMING,
AND RECOATING OF STEEL LINTELS AS SHOWN ON DRAWINGS.
H. REMOVAL AND REPLACEMENT OF DETERIORATED GLAZING PUTTY AT DISCRETE
WINDOW LOCATIONS.
I. INSTALLATION OF BACKER ROD AND SEALANT AT LOCATIONS OF COPPER
THROUGH-WALL FLASHING AND OTHER JOINTS BETWEEN CLADDING MATERIALS.
J. REMOVAL OF CORROSION FROM PORTICO ROOF BEAMS, INCLUDING APPLICATION
OF CORROSION-INHIBITING COATING AND REMOVAL AND REINSTALLATION OF
SHEET METAL FASCIA TO PERFORM WORK AT BEAMS.
K. REMOVAL AND REPLACEMENT OF ALL CONCRETE PORTICO BALCONY SLABS AND
COATING WITH A TRAFFIC-BEARING MEMBRANE OVER EXTENTS OF EXPOSED
CONCRETE, PROVIDING ADEQUATE SLOPE TO DRAIN.
L. REMOVAL OF CORROSION FROM LIGHT POLES, INCLUDING SURFACE PREPARATION
AND APPLICATION OF COATING SYSTEM TO MATCH EXISTING.
M. REMOVAL & REPLACEMENT OF EXISTING PLASTER SOFFIT AT PORTICOS.
N. REMOVAL OF DETERIORATED PLYWOOD CLOSURE IN MECHANICAL PIT AND
REPLACEMENT WITH NEW WALL & CURB.
O. REMOVAL & REPLACEMENT OF CORRODED METAL DOOR FRAME AT NORTH
BASEMENT ENTRANCE.
CODE COMPLIANCE
1. ALL WORK PERFORMED SHALL BE COMPLETED IN ACCORDANCE WITH ALL STATE,
FEDERAL, AND LOCAL CODES, ORDINANCES, AND LAWS, INCLUDING THE GOVERNING
CODES AS ADOPTED BY THE CITY OF GEORGETOWN, TEXAS, WHICH INCLUDE, BUT NOT
LIMITED TO, THE FOLLOWING:
A. 2003 INTERNATIONAL EXISTING BUILDING CODE
B. 2003 INTERNATIONAL BUILDING CODE.
C. STRUCTURAL CONCRETE: BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE, AND AMERICAN CONCRETE INSTITUTE ACI 318-05.
2. THE CONTRACTOR SHALL COORIDNATE WITH THE CITY AND SECURE ALL NECESSARY
PERMITS PRIOR TO STARTING THE WORK.
COORDINATION
1. THE CONTRACTOR SHALL COORDINATE WORK BETWEEN ALL TRADES AND BRING ANY
CONFLICTS TO THE ENGINEER'S ATTENTION PRIOR TO THE WORK BEING PERFORMED.
CONTRACTOR IS RESPONSIBLE FOR ALL COSTS FOR CORRECTIONS ASSOCIATED WITH THE
CONTRACTOR'S FAILURE TO PROPERLY COORDINATE THE WORK.
FAMILARITY WITH CONDITIONS
1. THE CONTRACTOR SHALL THOROUGHLY EXAMINE AND BECOME FAMILIAR WITH THE
REQUIREMENTS OF THE CONTRACT DOCUMENTS.
2. THE CONTRACTOR SHALL VISIT THE SITE OF THE PROPOSED WORK AND BECOME FULLY
ACQUAINTED WITH THE EXISTING CONDITIONS RELATING TO THE CONSTRUCTION, LABOR,
FACILITIES INVOLVED, DIFFICULTIES, RESTRICTIONS, AND THE LOGICAL EXTENSIONS OF
THE SCOPE ATTENDING THE PERFORMANCE OF THE CONTRACT.
3. THE CONTRACTOR SHALL IN NO WAY BE RELIEVED OF ANY OBLIGATION UNDER THE
CONTRACT BECAUSE OF THE CONTRACTOR'S FAILURE TO RECEIVE OR EXAMINE ANY
REQUIRED FORMS AND LEGAL DOCUMENTS, OR VISIT THE SITE AND BECOME FULLY
INFORMED OF ANY AND ALL CONDITIONS AND REQUIREMENTS THAT MAY IN ANY MANNER
AFFECT THE WORK TO BE PERFORMED.
DOCUMENTATION OF PRE-CONSTRUCTION PHOTOGRAPHS
1. THE CONTRACTOR SHALL PHOTOGRAPH AND/OR VIDEO DOCUMENT AND TAKE WRITTEN
NOTES OF EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF THE WORK ON THE
SITE. COPIES OF ALL DOCUMENTATION SHALL BE SUBMITTED TO THE OWNER OR ENGINEER
PRIOR TO COMMENCING WORK.
EXISTING CONDITIONS
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS.
DIMENSIONS SHOWN ON THE PLANS ARE APPROXIMATE, AND FIELD MEASUREMENTS AND
VERIFICATION WILL BE REQUIRED TO COMPLETE THE WORK. CONTRACTOR SHALL OBTAIN
ALL FIELD MEASUREMENTS AS NECESSARY TO COORDINATE WITH, AND MATCH NEW
CONSTRUCTION TO EXISTING CONDITIONS.
2. SOME INFORMATION SHOWN IN THE DRAWINGS, IN REGARDS TO EXISTING FEATURES, IS
NECESSARILY CONJECTURAL DUE TO HIDDEN CONDITIONS AT THE TIME OF PREPARATION.
IF CONDITIONS EXIST THAT DIFFER FROM THE DRAWINGS, OR ARE NOT ADEQUATELY
DETAILED, INFORM THE ENGINEER AND ADDITIONAL DETAILS OR INTERPRETATION WILL BE
PROVIDED. DO NOT PROCEED WITHOUT VERIFICATION FROM THE ENGINEER.
3. UNANTICIPATED CONDITIONS ENCOUNTERED DURING THE COURSE OF THE WORK THAT
REQUIRE ADDITIONAL REPAIR SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER.
NO ADDITIONAL REPAIR WORK SHALL BE PERFORMED UNLESS APPROVED IN ADVANCE BY
THE OWNER OR ENGINEER.
PLAN / DETAIL
NAME LABEL
ELEVATION
CALLOUT
SECTION
CALLOUT
DETAIL / VIEW
CALLOUT
KEYED NOTE /
OBSERVATION
ELEVATION
MARKER
CHANGE IN
ELEVATION
DRAWING
MATCHLINE
GRAPHICAL
PLAN SCALE
STRUCTURAL
GRIDLINE
NORTH ARROW
EL.= XX.XX'LEVEL 1
#
COMMON SYMBOLS LEGEND
0 2' 10'5'1'
A A
-
X"X"
-
-
-
-
-
-
-
-
-
-
X
SX.XX
X
SX.XX
X
SX.XX
X
1/8" = 1'-0"X
DRAWING LABEL
N
VICINITY MAP - NOT TO SCALE
TRUE
NORTH
NTAX EXEMPTION
1. THIS PROJECT IS TAX-EXEMPT. UPON SUBMITTING A REQUEST IN WRITING, THE OWNER
WILL PROVIDE A TAX-EXEMPT CERTIFICATE.
USE OF THE PREMISES
1. ALL ON-SITE EQUIPMENT ACCESS SHALL BE SCHEDULED WITH THE OWNER'S
REPRESENTATIVE 48 HOURS IN ADVANCE.
2. TYPICAL HOURS OF WORK, UNLESS ARRANGEMENTS ARE MADE WITH THE OWNER'S
REPRESENTATIVE: MONDAY - FRIDAY, 8:00am - 5:00pm
3. PRIOR TO COMMENCING WORK, COORDINATE HOURS OF WORK WITH THE OWNER OR
OWNER'S REPRESENTATIVE TO MINIMIZE THE IMPACT TO THE BUILDING'S DAILY
OPERATIONS.
4. PUBLIC ACCESS SHALL BE MAINTAINED DURING BUSINESS HOURS FOR THE DURATION OF
THE PROJECT.
5. THE CONTRACTOR SHALL PROVIDE ACCESS TO THE ENGINEER FOR OBSERVATION OF
REPAIRS THROUGHOUT THE DURATION OF THE PROJECT.
6. ALL WORKERS SHALL BE PROPERLY AND SAFELY DRESSED IN ACCORDANCE WITH OSHA
STANDARDS, AND DISPLAY APPROPRIATE BEHAVIOR AT ALL TIMES IN CONSTRUCTION AND
ADJACENT AREAS.
7. THREE ANGLE-IN PARKING SPACES ON 8TH STREET AT THE SOUTHEAST CORNER OF THE
SITE MAY BE USED FOR CONTRACTOR STAGING, MATERIALS, TOILET...ETC.
TEMPORARY FACILITIES
1. COORDINATE LOCATION AND PLACEMENT OF FIELD OFFICE, STAGING AREAS, MATERIAL
STORAGE, PORTABLE TOILETS, DUMPSTERS, AND ANY OTHER FACILITIES REQUIRED FOR
CONSTRUCTION WITH THE ENGINEER AND OWNER PRIOR TO, START OF MOBILIZATION &
CONSTRUCTION.
2. THE CONTRACTOR SHALL ERECT A CONSTRUCTION FENCE AS REQUIRED BY THE
PROJECT. COORDINATE LOCATIONS OF FENCING WITH THE ENGINEER AND OWNER PRIOR
TO CONSTRUCTION. REFERENCE SPECIFICATION SECTION 01 50 00.
3. AN ON-SITE STORAGE AREA IS TO BE ESTABLISHED BEFORE CONSTRUCTION FOR ALL
ITEMS MARKED “SAVE FOR RE-USE”. STORAGE IS TO BE PROTECTED IN A SECURE,
WEATHERPROOF LOCATION TO PREVENT DAMAGE TO THE CONTENTS.
SAFETY
1. CONTRACTOR IS SOLELY RESPONSIBLE FOR THEIR MEANS AND METHODS OF
CONSTRUCTION, AND SHALL PERFORM ALL WORK IN A SAFE AND CONSCIENTIOUS MANNER
TO PREVENT INJURIES.
2. CONTRACTOR IS SOLELY RESPONSIBLE FOR JOBSITE SAFETY, AND SHALL ENSURE THEIR
COMPLIANCE WITH OSHA STANDARDS FOR JOB SAFETY AND WORKER PROTECTION.
SAFETY MEASURES INCLUDE, BUT ARE NOT LIMITED TO ADEQUATE FALL PROTECTION,
ERECTION BRACING, BARRICADES, FENCING, SIGNS, FIRST-AID STATIONS, ETC.
3. CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, AND SHEETING REQUIRED FOR
SAFETY AND PROPER EXECUTION OF THE WORK.
4. PEDESTRIAN PROTECTION REQUIREMENTS: PROVIDE CANOPY AND/OR BARRICADES AT
SIDEWALKS AND OTHER PUBLICLY ACCESSIBLE AREAS THAT MAY BE SUBJECT TO FALLING
DEBRIS FROM THE WORK BEING PERFORMED. COORDINATE ACCESS REQUIREMENTS WITH
OWNER. BARRICADES AND CANOPIES SHALL MEET OR EXCEED THE APPLICABLE
REQUIREMENTS OF FEDERAL, STATE, AND LOCAL LAWS, CODES, AND REGULATIONS OF
AUTHORITIES HAVING JURISDICTION. AS A MINIMUM, CANOPIES SHALL COMPLY WITH
SECTION 3306, "PROTECTION OF PEDESTRIANS" OF THE 2003 EDITION OF THE
INTERNATIONAL BUILDING CODE (IBC). PROPERTY AND SITE SHALL BE RETURNED TO
PRE-CONSTRUCTION CONDITION SUBSEQUENT TO THE REMOVAL OF BARRICADES AND
CANOPIES.
5. THE CONTRACTOR SHALL PROVIDE WARNING SIGNS, BARRIERS OR BARRICADES, AS
REQUIRED AND OTHERWISE NECESSARY TO SEPARATE THE WORK AREAS FROM THE
PUBLIC, TO PREVENT PEDESTRIANS AND TRAFFIC FROM ENTERING THE WORK AREAS, AND
TO PROVIDE A SAFE AND ORDERLY FLOW OF PEDESTRIAN AND VEHICLE TRAFFIC THROUGH
REQUIRED ENTRANCES AND EXITS DURING THE REPAIR WORK.
FIRE PROTECTION
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIRE PROTECTION AND FIRE WATCH
DURING ALL CONSTRUCTION OPERATIONS.
2. NO SMOKING OR TOBACCO USE SHALL BE PERMITTED IN THE BUILDING OR ON ANY
PROPERTY OWNED BY WILLIAMSON COUNTY.
3. CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY FIRE EXTINGUISHERS UNTIL
SUBSTANTIAL COMPLETION.
PROTECTION OF BUILDING & SITE
1. CONTRACTOR SHALL PROTECT ALL EXISTING BUILDING SURFACES FOR THE DURATION
OF THE PROJECT. ANY DAMAGE TO THE EXISTING STRUCTURE OR BUILDING CONTENTS
THAT HAS BEEN DETERMINED TO BE CAUSED BY THE CONTRACTOR, OR CONSTRUCTION
PRACTICES THAT OCCUR FOLLOWING THE NOTICE TO PROCEED, SHALL BE CORRECTED TO
PRE-CONSTRUCTION CONDITION AT NO EXPENSE TO THE OWNER.
2. CONTRACTOR SHALL PROTECT ALL EXISTING TREES, LANDSCAPING, SITE LIGHTING,
IRRIGATION, SIDEWALKS, AND SITE FEATURES FROM DAMAGE FOR THE DURATION OF THE
PROJECT. IF DAMAGED DURING THE COURSE OF WORK, THE CONTRACTOR SHALL REPAIR
THE DAMAGED AREAS TO PRE-CONSTRUCTION CONDITION PRIOR TO THE COMPLETION OF
THE PROJECT AT NO EXPENSE TO THE OWNER.
3. DO NOT PLACE LOADS ON THE STRUCTURE OR STORE DEMOLISHED MATERIALS ON THE
STRUCTURE IN A MANNER THAT WILL ENDANGER IT.
4. CONTRACTOR SHALL KEEP THE BUILDING SECURE AND WEATHER-TIGHT AT ALL TIMES.
5. ALL CONSTRUCTION MATERIALS IN USE OR KEPT IN ELEVATED AREAS, SUCH AS
BALCONIES AND ROOFS, SHALL REMAIN SECURED TO ENSURE THE MATERIALS DO NOT
BECOME AIRBORNE AND CAUSE INJURY OR DAMAGE TO THE BUILDING OR ITS OCCUPANTS.
BUILDING MAINTENANCE
1. CONTRACTOR SHALL PERFORM SITE CLEAN UP ON A DAILY BASIS, AND MAINTAIN THE
SITE IN A CLEAN AND ORDERLY MANNER.
2. CONTRACTOR SHALL ADEQUATELY SECURE ALL WORK AT THE END OF EACH WORK DAY.
3. AREAS THAT ARE NOT DIRECTLY UNDER CONSTRUCTION THAT ARE USED AS PATHWAYS
TO TRANSPORT MATERIALS, OR TO REMOVE TRASH, ARE TO BE KEPT CLEAN AT ALL TIMES.
THIS MAINTENANCE INCLUDES, BUT NOT LIMITED TO DUSTING, SWEEPING, MOPPING, AND
PICKING UP TRASH AS REQUIRED TO KEEP THE AREAS FREE OF WASTE MATERIALS,
DEBRIS, AND RUBBISH.
QUALITY ASSURANCE
1. WHERE APPLICABLE, THE CONTRACTOR SHALL BE A LICENSED APPLICATOR OR
INSTALLER OF ALL SPECIFIED PROPRIETARY PRODUCTS AND MATERIALS.
2. THE PRESENCE OF THE ENGINEER OR TESTING AGENCY AT THE JOBSITE DOES NOT
RELIEVE CONTRACTOR OF THE OBLIGATION TO PERFORM THE WORK IN ACCORDANCE
WITH THE CONTRACT DOCUMENTS.
3. THE OWNER AND ENGINEER SHALL NOT HAVE CONTROL OVER OR CHARGE OF AND
SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND SAFETY PROGRAMS IN
CONNECTION WITH THE PROJECT.
4. THE OWNER AND ENGINEER MAY PERFORM QUALITY CONTROL TESTS ON A RANDOM
BASIS FROM TIME TO TIME TO EVALUATE INSTALLATION OF THE NEW CONSTRUCTION FOR
CONFORMANCE TO THE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL MAKE
ACCESS AVAILABLE TO INSPECT AND TEST THE SPECIFIED AREA AND MAKE APPROPRIATE
REPAIRS (BASED ON UNIT COSTS) AFTER COMPLETION OF INSPECTION. ANY DEFECTIVE
WORK WILL BE REPAIRED AT NO COST TO THE OWNER.
WARRANTY
1. ALL WORK PERFORMED SHALL BE WARRANTED BY THE GENERAL CONTRACTOR AS
REQUIRED BY THE CONTRACT SPECIFICATIONS.
STRUCTURAL NOTES
DESIGN LOADS
1. LIVE LOADS: PRINCIPAL DESIGN LIVE LOADS ARE SHOWN BELOW. ALL LIVE LOADS
WETHER LISTED BELOW OR NOT ARE BASED ON THE REQUIREMENTS OF THE BUILDING
CODE CITED IN THE GENERAL NOTES ABOVE UNLESS THE LOADS ARE GREATER.
A. BALCONY LIVE LOADS: 100 PSF
2. DEAD LOADS INCLUDE THE SELF-WEIGHT OF THE STRUCTURAL AND ARCHITECTURAL
ELEMENTS. ANY CHANGES FROM THE CONSTRUCTION MATERIALS FROM THOSE SHOWN
ON THE ARCHITECTURAL OR STRUCTURAL DRAWINGS SHALL BE REPORTED BY THE
GENERAL CONTRACTOR TO THE STRUCTURAL ENGINEER FOR VERIFICATION OF THE LOAD
CARRYING CAPACITY OF THE STRUCTURE.
CONCRETE REPAIR
1. REFERENCE SECTION 03 01 30 OF THE TECHNICAL SPECIFICATIONS FOR COMPLETE
CONCRETE REPAIR REQUIREMENTS.
2. REQUIRED MATERIAL PROPERTIES
A. COMPRESSIVE STRENGTH AT 28 DAYS (f'c): 4000 PSI
3. REINFORCING STEEL:
A. EXISTING REINFORCEMENT EXPOSED DURING CONCRETE REPAIRS SHALL BE
CLEANED AND COATED WITH CORROSION-INHIBITING COATING.
05-18-2015 REVISED PROJECT NOTES1
1
1
1
BALCONY AT
NORTH PORTICO
BUILDING INTERIOR
NOT IN SCOPE
N
1LEVEL-2 PLAN1/8" = 1'-0"
S2.1
3
S2.1
2 TYPICAL BALCONY TOP
SURFACE REPAIR PLAN
TYPICAL BALCONY SOFFIT
REFLECTED REPAIR PLAN
S2.1
3
S2.1
2 TOP SURFACE REPAIR
PLAN AT OPP. BALCONY
REFLECTED SOFFIT REPAIR
PLAN AT OPP. BALCONY
S2.1
3
S2.1
2 TOP SURFACE REPAIR
PLAN AT SIM. BALCONY
REFLECTED SOFFIT REPAIR
PLAN AT SIM. BALCONY S2.1
3
S2.1
2TOP SURFACE REPAIR
PLAN AT SIM. BALCONY
REFLECTED SOFFIT REPAIR
PLAN AT SIM. BALCONY
(SIM.)(SIM.)
(OPP.)
BALCONY AT
SOUTH PORTICO
BA
LC
ON
Y A
T
EA
ST
PO
RT
ICO
BA
LC
ON
Y A
T
WE
ST
PO
RT
ICO
2TYPICAL TOP SURFACE BALCONY REPAIR PLANS1/4" = 1'-0"
1A: TYPICAL TOP SURFACE DEMOLITION PLAN
EXISTING BALCONY FLOOR
DRAINS TO REMAIN, TYP.
EXISTING MASONRY WALL BELOW
TO REMAIN; F.V. LOCATION, TYP.
±1
0"
(F.V
.)
S4.4
6A
SAWCUT EXISTING BALCONY SLABS
ALONG PERIMETER, THEN CHIP BACK
& REMOVE EXISTING CONC., TYP.
REMOVE & DISPOSE OF EXISTING
BALCONY PARGE COAT & STRUCT'L.
CONC. SLABS, TYP.
EXISTING BRICK COLUMNS
& BALCONY PERIMETER
WALLS TO REMAIN, TYP.
EXISTING STEEL BEAMS
BELOW TO REMAIN; F.V.
LOCATIONS, TYP.
S4.4
6A
SIM.
S4.4
6A
S4.4
5A
S4.4
4A
SLOPE T.O. SLAB SURFACES TO
DRAIN, 18"/FT. MIN. SLOPE, TYP.
RID
GE
PROVIDE SLAB RIDGE AT
BALCONY CENTERLINE, TYP.
S4.4
5B
S4.4
4B
NEW 5" MIN. THICK CONC. SLAB, REINF. W/
#4 BARS AT 10" O.C. EA. WAY; REF. 1/S4.4
FOR TYP. INSTALLATION REQUIREMENTS
NOT OTHERWISE SHOWN
EXISTING PARGE COAT AT
THRESHOLD TO REMAIN
±30'-0" (E&W PORTICOS)
±36'-4" (N&S PORTICOS)
±1
0'-0"
(E&
W P
OR
TIC
OS
)
±1
4'-0"
(N&
S P
OR
TIC
OS
)V
AR
IES
INT
ER
IOR
EXISTING FLOOR
DRAINS, TYP.
EXISTING MASONRY WALL
BELOW; F.V. LOCATION, TYP.
EXISTING PARGE COAT
AT DOOR THRESHOLD
±30'-0" (E&W PORTICOS)
±36'-4" (N&S PORTICOS)
±1
0'-0"
(E&
W P
OR
TIC
OS
)
±1
4'-0"
(N&
S P
OR
TIC
OS
)V
AR
IES
INT
ER
IOR
1
2B: TYPICAL TOP SURFACE REPAIR PLAN
S4.4
6B
S4.4
6B
S4.4
1B
TYP.
S4.4
1A
TYP.
3TYPICAL BALCONY SOFFIT REFLECTED REPAIR PLANS1/4" = 1'-0"
3A: TYPICAL SOFFIT DEMOLITION - REFLECTED PLAN 3B: TYP. SOFFIT REPAIR - REFLECTED PLAN
±30'-0" (E&W PORTICOS)
±36'-4" (N&S PORTICOS)
±1
0'-0"
(E&
W P
OR
TIC
OS
)
±1
4'-0"
(N&
S P
OR
TIC
OS
)V
AR
IES
INT
ER
IOR
REMOVE, CLEAN, & STORE EXISTING BRICK MASONRY
AT BEARING ENDS OF STEEL BEAMS; CLEAN & COAT ALL
CORRODED BEARING P's PER 7/S4.3, TYP. AT ALL BEAMSL
INSTALL SHORING AT
EXISTING BEAM ENDS
PRIOR TO DEMOLITION
(5 KIP SERVICE LOAD)
EXISTING DRAINS FROM
ABOVE TO REMAIN, TYP.
REMOVE & DISPOSE OF ALL
EXISTING PLASTER FINISHES
AS REQ'D. AT BALCONY SOFFIT,
PREPARE ALL EXPOSED CONC.
SURFACES AS SPECIFIED, TYP.
EXISTING BRICK MASONRY
COLUMNS TO REMAIN, TYP.
EXISTING STEEL BEAMS TO REMAIN,
REMOVE & DISPOSE OF EXISTING
PLASTER & ALL WOOD BLOCKING
PER 6/S4.2; TYP. AT ALL BEAMS
EXISTING BRICK MASONRY
ARCHES TO REMAIN, TYP.
INSTALL NEW BACKER ROD &
SEALANT JOINTS AT SOFFIT
PERIMETER, REF. 2/S4.4, TYP.
PAINT ALL EXISTING PLASTERED
LINTELS AS REQ'D. TO MATCH
NEW STUCCO SOFFIT, TYP.
SHORING AT BEAM ENDS
SHALL REMAIN IN PLACE
UNTIL WORK HAS BEEN
COMPLETED, TYP.
±1
0'-0"
(E&
W P
OR
TIC
OS
)
±1
4'-0"
(N&
S P
OR
TIC
OS
)V
AR
IES
INT
ER
IOR
±30'-0" (E&W PORTICOS)
±36'-4" (N&S PORTICOS)
S4.3
7
S4.4
6
TYP.
S4.3
4
TYP.
TYP.
S4.4
1B
TYP.
S4.3
7
TYP.
NEW CEMENTITIOUS STUCCO
SOFFIT, INSTALL & PAINT AS
SPECIFIED, REF. 2/S4.4; TYP.
AT ALL REMOVED AREAS
CLEAN STEEL BEAM SURFACES OF
CORROSION, THEN PRIME & PAINT
AS SPECIFIED; INSTALL NEW WOOD
WEB BLOCKING & STUCCO FINISHES
AS REQ'D. PER 1B/S4.4, TYP.
INSTALL NEW CONT. BACKER
ROD & SEALANT JOINT AT ALL
EXISTING PLASTERED LINTELS
PER 4/S4.3, TYP.
REINSTALL EXISTING BRICK, MASONRY OR
PROVIDE NEW AT ALL REMOVED AREAS AS
REQ'D. TO MATCH EXISTING, REF. 7/S4.3; TYP.
EXISTING PLASTERED LINTELS
TO REMAIN, SAWCUT PERIMETER
AS REQ'D. PER 4/S4.3, TYP.
1
S4.4
1A
TYP.
Exterior Masonry
Cladding Repairs
Williamson County
Historic Courthouse710 Main Street
Georgetown, Texas 78626
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
512.257.4800 tel | 512.219.9883 fax
Headquarters & Laboratories : Northbrook, Illinois
Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit
Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
MATERIAL SCIENTISTSWJE
Austin, Texas 78717
9511 N. Lake Creek Parkway
ARCHITECTS
ENGINEERS
Texas Registered Engineering Firm F-0093
Cop
yri
ght
201
5.
All
rig
hts
res
erved
. N
o p
art
of
this
do
cum
ent
may
be
rep
rod
uce
d i
n a
ny
fo
rm o
r b
y a
ny
mea
ns
wit
hout
per
mis
sio
n f
rom
Wis
s, J
ann
ey,
Els
tner
Ass
oci
ates
, In
c. (
WJE
). W
JE d
iscl
aim
s an
y r
esponsi
bil
ity f
or
its
unau
thori
zed u
se.
No. DATE DESCRIPTION
WJE PROJECT No.:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJ. MANAGER:
SCALE:
2013.0373.0
May 18, 2015
DMC / LMM
ELB / SWF
CJL
AS NOTED
SHEET TITLE:
SHEET No.:
WJE SEAL:
PROJECT:
CLIENT:
Williamson County
Purchasing Department301 SE Inner Loop, Suite 106
Georgetown, Texas 78626
THIS DOCUMENT IS RELEASED FOR PRICINGPURPOSES ONLY UNDER THE AUTHORITY OF:
CARL J. LAROSCHE, P.E.(TEXAS P.E. No. 91870)
MAY 18, 2015
NOT FOR
CONSTRUCTION
PRELIMINARY
PRICING SUBMITTAL
2nd Floor
Portico Repair Plans
S2.1
05-18-2015 BALCONY & SOFFIT REPAIR PLANS1
1
1 1
1
1
TYP. SLAB REINFORCING:
#4 AT 10" O.C. EACH WAY
EX
IST
ING
BA
LC
ON
Y, T
YP
.
1CONCRETE BALCONY REPLACEMENT SECTIONS, TYP.3" = 1'-0"
REMOVE & DISPOSE OF EXISTING
PARGE COAT (±2), TYP.
REMOVE & DISPOSE OF EXISTING
STRUCT'L. CONC. SLAB (±3"), TYP.
CO
NC
. S
LA
B:
5"
MIN
. (A
T L
.P.)
7"
MA
X.
(AT
H.P
.)
SLOPE TO DRAIN,
REF. PLAN, TYP.
RUBBED FINISH AT
B.O. SLAB, TYP.
TROWEL FINISH AT
T.O. SLAB, TYP.
2"
TY
P.
EXISTING STEEL BEAM TO REMAIN;
CLEAN & PREPARE SURFACES AS
SPECIFIED, TYP.
REMOVE & DISPOSE OF
ALL EXISTING PLASTER
FINISHES AT BALCONY
SOFFIT & BEAMS, TYP.
REMOVE & DISPOSE OF EXISTING
WOOD BLOCKING & FASTENERS
AS REQ'D. AT BEAM WEBS, TYP.
1A: TYP. BALCONY DEMOLITION SECTION
EXISTING BEAM
±1"
OUTSIDE STUCCO CORNER
BEAD, REF. 3C/S4.4, TYP.
INSIDE STUCCO CORNER
BEAD, REF. 3B/S4.4, TYP.
NEW DBL. 2x, SOLID P.T.
WOOD BLOCKING, TYP.
AT EA. SIDE OF BEAM
NEW STUCCO CLADDING,
SYSTEM AT CONC. SOFFIT
& BEAM, REF. 2/S4.4, TYP.
NEW SELF-FURRING GALV. LATH
FASTENED TO CONC. SOFFIT &
WOOD BLOCKING IN 6"x12" GRID
AS SPECIFIED , TYP.
PROVIDE 2" COVER
AT B.O. SLAB, TYP.
±1
'-0
", T
YP
.
EXISTING STEEL BEAM, PRIME
& PAINT AS SPECIFIED, TYP.
1B: TYP. BALCONY INSTALLATION SECTION
±8", TYP.
EX
IST
ING
ST
EE
L B
EA
M
±1
",
TY
P.
CEMENTITIOUS STUCCO BASE
COAT, AS SPECIFIED, TYP.
CEMENTITIOUS STUCCO FINISH
COAT, AS SPECIFIED, TYP.
NEW SELF-FURRING GALV. LATH
FASTENED TO CONC. SOFFIT IN 6"x12"
GRID W/ SPECIFIED FASTENERS, TYP.
2NEW STUCCO SOFFIT CLADDING SYSTEM, TYP.1" = 2"
NEW CEMENTITIOUS STUCCO CLADDING
SYSTEM TO BE PAINTED AS SPECIFIED, TYP.
NE
W C
ON
C. B
ALC
ON
Y
SO
FF
IT, R
EF
. 1/S
4.4
, T
YP
.
INSIDE STUCCO CORNER
BEAD AS SPECIFIED, TYP.
WOOD BLOCKING
AT BEAM WEB
TIE LATH TO EXP. METAL
FLANGES AT 6" O.C., TYP.
FASTEN TO LATH WOOD
AS SPECIFIED, TYP.
NEW STUCCO CLADDING,
SYSTEM, REF. 2/S4.4, TYP.
OUTSIDE STUCCO CORNER
BEAD AS SPECIFIED, FASTEN
TO BLOCKING & STEEL BEAM
BOTTOM FLANGE, TYP.
NEW STUCCO CLADDING,
SYSTEM, REF. 2/S4.4, TYP.
TIE LATH TO EXP. METAL
FLANGES AT 6" O.C., TYP.
3B: STUCCO TERMINATION AT INSIDE CORNER
3C: STUCCO TERMINATION AT OUTSIDE CORNER
3STUCCO CLADDING TERMINATION SECTIONS, TYP.1" = 2"
TIE LATH TO EXP. METAL
ACCESSORY FLANGE AT
6" O.C., TYP.
NEW CONT. BACKER ROD &
SEALANT JOINT AT SOFFIT
PERIMETER, TYP.
STUCCO J-SCREED
AS SPECIFIED, TYP.
12" JOINT,TYPICAL
EXISTING BRICK
MASONRY WALL
NEW STUCCO CLADDING,
SYSTEM, REF. 2/S4.4, TYP.
3A: STUCCO TERMINATION AT WALL
4A: BALCONY DEMOLITION SECTION
5A: BALCONY DEMOLITION SECTION
6A: BALCONY DEMOLITION SECTION
4BALCONY SECTION AT EXISTING MASONRY WALL, TYP.3" = 1'-0"
5BALCONY SECTION AT EXTERIOR DOOR, TYP.3" = 1'-0"
6BALCONY SECTION AT EXISTING MASONRY ARCH, TYP.3" = 1'-0"
±10", F.V.
4B: BALCONY REPAIR SECTION
5B: BALCONY REPAIR SECTION
6B: BALCONY REPAIR SECTION
REMOVE & DISPOSE OF EXISTING
PARGE COAT (±2), TYP.
REMOVE & DISPOSE OF EXISTING
STRUCT'L. CONC. SLAB (±3"), TYP.
18" MIN.
REMOVE & DISPOSE OF EXISTING
PLASTER SOFFIT FINISHES, TYP.
18" MIN. EXISTING SLAB REINF.
TO REMAIN; CLEAN & COAT, TYP.
REMOVE & DISPOSE OF EXISTING
PARGE COAT (±2), TYP.
REMOVE & DISPOSE OF EXISTING
STRUCT'L. CONC. SLAB (±3"), TYP.
REMOVE & DISPOSE OF EXISTING
PLASTER SOFFIT FINISHES, TYP.
SAWCUT EXISTING BALCONY SLAB
ALONG PERIMETER, THEN CHIP BACK
& REMOVE EXISTING CONC., TYP.
REMOVE EXISTING BRICK
COURSE AS REQ'D., TYP.
±10", F.V.
REMOVE & DISPOSE OF EXISTING
PARGE COAT (±2), TYP.
REMOVE & DISPOSE OF EXISTING
STRUCT'L. CONC. SLAB (±3"), TYP.
REMOVE & DISPOSE OF EXISTING
PLASTER SOFFIT FINISHES, TYP.
12" MIN. EXISTING SLAB REINF.
TO REMAIN; CLEAN & COAT, TYP.
SAWCUT EXISTING BALCONY SLAB
ALONG PERIMETER, THEN CHIP BACK
& REMOVE EXISTING CONC., TYP.
EXISTING MASONRY WALL
& ARCH TO REMAIN, TYP.
EXISTING STRUCT'L.
CONC. SLAB TO REMAIN
SAWCUT EXISTING BALCONY SLAB
ALONG PERIMETER, THEN CHIP BACK
& REMOVE EXISTING CONC., TYP.
EXISTING MASONRY
WALL TO REMAIN, TYP.
EXISTING MASONRY
WALL TO REMAIN, TYP.
EXISTING PARGE COAT &
STRUCT'L. SLAB TO REMAIN
1'-0"±10", F.V.
6",
MIN
.6
", M
IN.
2"
TY
P.
CO
NC
. S
LA
B,
RE
F. 1/S
4.4
, T
YP
.
#4x DOWELS AT 10" O.C., PROVIDE
6" MIN. EPOXY EMBED INTO EXISTING
MASONRY W/ HILTI-HY 70, TYP.
#4 AT 10" O.C.
EA. WAY, TYP.
EXISTING MASONRY
WALL, TYP.
128
5", TYP.
±1
",
TY
P.
#4x DOWELS AT 10" O.C., PROVIDE
6" MIN. EPOXY EMBED INTO EXISTING
MASONRY W/ HILTI-HY 70, TYP.
8125", TYP.
2"
TY
P.
CO
NC
. S
LA
B,
RE
F. 1/S
4.4
, T
YP
.
#4 AT 10" O.C.
EA. WAY, TYP.
NEW REINF. CONC.
BALCONY SLAB, TYP.
EXISTING MASONRY
WALL, TYP.
NEW STUCCO CLADDING,
SYSTEM, REF. 2/S4.4, TYP.
±1
",
TY
P.
REF. 1B/S4.4 FOR TYP. CONC.
SLAB & STUCCO SOFFIT INFO.
NOT OTHERWISE SHOWN, TYP.
CAST EXISTING SLAB
REINF. INTO NEW CONC.
W/ 3 4", MIN. COVER, TYP.
NEW CONT. BACKER ROD &
SEALANT JOINT AT SOFFIT
PERIMETER, TYP.
NEW CONT. BACKER ROD &
SEALANT JOINT AT SOFFIT
PERIMETER, TYP.
NEW REINF. CONC.
BALCONY SLAB, TYP.
NEW STUCCO CLADDING,
SYSTEM, REF. 2/S4.4, TYP.
REF. 1B/S4.4 FOR TYP. CONC.
SLAB & STUCCO SOFFIT INFO.
NOT OTHERWISE SHOWN, TYP.
EXISTING PARGE COAT
& CONC. SLAB AT DOOR
2"
TY
P.
12", MIN
.
#4x DOWELS AT 10" O.C., PROVIDE
12" MIN. EPOXY EMBED INTO EXISTING
MASONRY W/ HILTI-HY 70, TYP.
5", TYP.
CO
NC
. S
LA
B,
RE
F. 1/S
4.4
, T
YP
.±1
",
TY
P.
1218
NEW REINF. CONC.
BALCONY SLAB, TYP.
NEW STUCCO CLADDING,
SYSTEM, REF. 2/S4.4, TYP.
REF. 1B/S4.4 FOR TYP. CONC.
SLAB & STUCCO SOFFIT INFO.
NOT OTHERWISE SHOWN, TYP.
EXISTING MASONRY
WALL, TYP.
CAST EXISTING SLAB REINF. INTO
NEW CONC. W/ 3 4", MIN. COVER, TYP.
NEW CONT. BACKER ROD &
SEALANT JOINT AT SOFFIT
PERIMETER, TYP.
REMOVE ADD'L. SLAB AS REQ'D.
AT DOWEL LOCATIONS, TYP.
ROUGHEN ALL EXPOSED CONC.
SURFACES TO 14" AMPLITUDE, TYP.
ROUGHEN ALL EXPOSED CONC.
SURFACES TO 14" AMPLITUDE, TYP.
Exterior Masonry
Cladding Repairs
Williamson County
Historic Courthouse710 Main Street
Georgetown, Texas 78626
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
512.257.4800 tel | 512.219.9883 fax
Headquarters & Laboratories : Northbrook, Illinois
Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit
Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
MATERIAL SCIENTISTSWJE
Austin, Texas 78717
9511 N. Lake Creek Parkway
ARCHITECTS
ENGINEERS
Texas Registered Engineering Firm F-0093
Cop
yri
ght
201
5.
All
rig
hts
res
erved
. N
o p
art
of
this
do
cum
ent
may
be
rep
rod
uce
d i
n a
ny
fo
rm o
r b
y a
ny
mea
ns
wit
hout
per
mis
sio
n f
rom
Wis
s, J
ann
ey,
Els
tner
Ass
oci
ates
, In
c. (
WJE
). W
JE d
iscl
aim
s an
y r
esponsi
bil
ity f
or
its
unau
thori
zed u
se.
No. DATE DESCRIPTION
WJE PROJECT No.:
ISSUE DATE:
DRAWN BY:
REVIEWED BY:
PROJ. MANAGER:
SCALE:
2013.0373.0
May 18, 2015
DMC / LMM
ELB / SWF
CJL
AS NOTED
SHEET TITLE:
SHEET No.:
WJE SEAL:
PROJECT:
CLIENT:
Williamson County
Purchasing Department301 SE Inner Loop, Suite 106
Georgetown, Texas 78626
THIS DOCUMENT IS RELEASED FOR PRICINGPURPOSES ONLY UNDER THE AUTHORITY OF:
CARL J. LAROSCHE, P.E.(TEXAS P.E. No. 91870)
MAY 18, 2015
NOT FOR
CONSTRUCTION
PRELIMINARY
PRICING SUBMITTAL
Sections & Details
S4.4
05-18-2015 SUPPLEMENTAL REPAIR DETAILS1
1