Chapter 2 Site Maintenance ......................................................................................................... 2-12.1 Overview............................................................................................................................ 2-12.2 Site Administrationship ...................................................................................................... 2-12.3 Start Site Operation ........................................................................................................... 2-32.4 View Resource................................................................................................................... 2-42.5 Force Load SW.................................................................................................................. 2-52.6 SW Activate ....................................................................................................................... 2-62.7 Site Hierarchical Reset ...................................................................................................... 2-82.8 Site Test............................................................................................................................. 2-92.9 Site Environment Monitoring............................................................................................ 2-10
Huawei Technologies Proprietary
i
-
8/13/2019 09 Site Maintenance
2/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
Chapter 2 Site Maintenance
2.1 Overview
There may be one or more cells at a site. The maintenance of the site involves the
maintenance over the entire BTS.
Figure 2-1 shows the interface [Site Maintenance Terminal System] in the BTS
maintenance console.
In the following sections, site maintenance functions are explained in detail.
Figure 2-1 The interface [Site Maintenance Terminal System]
2.2 Site Administrationship
I. Function
Site administrationship is the authority to set the various BTS parameters. BTS
parameters can be set either at the BSC or the local BTS maintenance terminal.
However, BTS parameter setting cannot be performed at the same time at both the
Huawei Technologies Proprietary
2-1
-
8/13/2019 09 Site Maintenance
3/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
BSC and the local BTS terminal. Therefore, site administrationship will be granted to
one side at a time.
When a site is installed and begins to run, BSC has the site administrationship by
default. Therefore the maintenance personnel need to obtain site administrationship
before performing any operation at a BTS terminal.
When the operation is over, please release the site administrationship.
II. Access
Activate BTS terminal maintenance console, and select [Site/Site
Administrationship]. Click or in the popped up dialogue box
to obtain or release site administrationship, and the operational result will be
displayed in this box, as shown in Figure 2-2.
Figure 2-2 Site administrationship (obtain administrationship)
When the operation is over, the administrationship must be released. Otherwise,
maintenance personnel will be blocked from performing remote maintenance.
The interface of releasing the administrationship is shown in Figure 2-3.
Huawei Technologies Proprietary
2-2
-
8/13/2019 09 Site Maintenance
4/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
Figure 2-3 Release the administrationship
2.3 Start Site Operation
I. Function
To put the site data set in BTS operation and maintenance unit into effect and start
the service of the site.
II. Access
Activate BTS terminal maintenance console, and select [Site/Site OpStart]. Click
in the popped up message box [Start Site Operation]. The result of the
operation will be displayed in the status bar, as shown in Figure 2-4.
Figure 2-4 Start Site Operation
Huawei Technologies Proprietary
2-3
-
8/13/2019 09 Site Maintenance
5/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
2.4 View Resource
I. Function
The maintenance personnel can view the status of resource utilization in the
terminal maintenance system of the BTS, specifically, the utilization ratio of the CPU
and the RAM of TMU and TRX.
II. Access
Activate BTS terminal maintenance console, and select [Site/View Resource], and
the resource utilization status of the TRX and the TMU of the site will be displayed in
the popped-up window.
Select in [Resource Type] to determine the type of resource whose utilization
status is to be viewed. As is shown in Figure 2-5,Figure 2-6.
Figure 2-5 View the status of resource
Huawei Technologies Proprietary
2-4
-
8/13/2019 09 Site Maintenance
6/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
Figure 2-6 View CPU status
2.5 Force Load SW
I. Function
The BTS software can be upgraded from both the local and the remote terminal.
Software upgrading for TMU, TRX and PBU can therefore be easily achieved.
II. Access
Activate BTS terminal maintenance console, select [Site/Forced Load SW], and
the dialogue box [SW Download]will pop up.
Select in this dialogue box the name of the software and the type of the files to be
loaded, and click .
The progress of software loading will be displayed at the maintenance console, as
shown in Figure 2-7.
When it is promoted that Software loading successful, click to complete
the forced software loading from the maintenance console to the BTS.
Huawei Technologies Proprietary
2-5
-
8/13/2019 09 Site Maintenance
7/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
Figure 2-7 The Dialogue Box [SW Download]
III. Interface description
For the description of the interface in Figure 2-7,please see Table 2-1 below.
Table 2-1 [SW Download]
Field Descript ion Value range Recommended value
File NameThe name of the file saved on themaintenance console that is to beloaded
SendWindow Size
The data for software loading istransferred with the window size as oneunit
1~49 49
VersionVersion number of the software to beloaded
Must be the same as the versionnumber specified in the file to beloaded, otherwise the loading willfail.
File ID
For which type of board the software
upgrading is to be carried out
Must be the same as the type of
the file to be loaded.
2.6 SW Activate
I. Function
After the forced BTS software loading, activate the software. The software upgrading
task is not yet completed before the loaded software is activated.
Huawei Technologies Proprietary
2-6
-
8/13/2019 09 Site Maintenance
8/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
II. Access
Activate BTS terminal maintenance console, select [Site/SW Activate], and the
interface [SW Activate](as shown in Figure 2-8 and Figure 2-9)will pop up. Input
the version of the software to be activated, select the corresponding board number
and file ID, and click . If the activation is successful, the prompt SW activation
request is confirmed will be displayed.
Figure 2-8Activating the TMU board software
Figure 2-9Activating the TRXboard software
Huawei Technologies Proprietary
2-7
-
8/13/2019 09 Site Maintenance
9/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
III. Interface description
For the description of the software activation interface, see Table 2-2.
Table 2-2 The Interface [SW Activate]
Field Meaning Value range Recommended value
VersionVersion number of theloaded software
Must be the same as the versionnumber of the software to be loaded,otherwise the activation will fail.
Board No.Number of the specifiedboard that is to beactivated
Format: 0, 1, 0-X,etc. (X being thenumber of the TRXsconfigured)
File IDType of board for whichthe software upgrading isto be carried out
2.7 Site Hierarchical Reset
I. Function
Site resetting is performed as a remedy when a site is abnormal.
Resetting a site will stop the services of the cells for several minutes under this site.
Therefore, care should be taken with this function.
II. Access
Enter the maintenance console of the BTS, select [Site/Site Reset Hierarchically].
The interface [Site Hierarchical Reset]will pop up. Select the level of the resetting
in this interface, and click , as shown in Figure 2-10.
Huawei Technologies Proprietary
2-8
-
8/13/2019 09 Site Maintenance
10/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
Figure 2-10 The 'Site Hierarchical Reset' interface
III. Interface description
For description of the interface [Site Hierarchical Reset], see Table 2-3.
Table 2-3 Site resetting levels
Reset level Meaning
First Level Reset Currently not supported by the BTSs.
Please see the definition of this level of resetting on the interface.
Second Level ResetCurrently not supported by the BTSs.
Please see the definition of this level of resetting on the interface.
Third Level Reset
Please see the definition of this level of resetting on the interface.
In this level of resetting, the base station applies to BSC side for the re-sendingof data configuration.
Fourth Level ResetPlease see the definition of this level of resetting on the interface. In this levelof resetting, base station TMU hardware resetting is performed, and the base
station re-applies for BSC data configuration.
2.8 Site Test
I. Function
To test the functional boards configured for the site, and return the test results.
Huawei Technologies Proprietary
2-9
-
8/13/2019 09 Site Maintenance
11/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
II. Access
Activate BTS terminal maintenance console, and select [Site/Site Test]. The
interface [Site Test] will pop up. Click , and the test results will be
displayed in this interface, as shown in Figure 2-11.
Figure 2-11 Site test results
2.9 Site Environment Monitoring
I. Function
To implement operations on the environment monitoring box such as resetting the
environment monitoring box, clearing the burglary alarm, setting the upper and
lower limits for humidity and temperature alarms, relay operation and disable the
EAC alarm.
Caution:
In this system, burglary alarm, fire alarm and smoke alarm are all reported as burglary alarm.
Therefore, the occurrence of any of them will trigger the burglary alarm.
II. Access
Activate BTS terminal maintenance console, and select [Site/Environment
Monitoring Setting]. The interface [Environment Monitoring Setting]will pop up,
as shown in Figure 2-12.
Huawei Technologies Proprietary
2-10
-
8/13/2019 09 Site Maintenance
12/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
Figure 2-12 Environment monitoring setup
Resetting of the environment monitoring instrument is performed when the
equipment is in abnormal service. Select Reset in [Select Operation Type]. Click
, then the resetting can be performed and the operational result will be
displayed, as shown in Figure 2-13.
Figure 2-13 Resetting operation
When the burglary alarm is confirmed or cleared, please clear the burglary alarm
record. Select Clear Burglary alarm in [Select Operation Type]. Click , and
Huawei Technologies Proprietary
2-11
-
8/13/2019 09 Site Maintenance
13/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
the burglary alarm record will be cleared, and the operational result will be displayed
in the status bar, as shown in Figure 2-14.
Figure 2-14 Clear burglary alarm
Conditions for the generation of environment alarms can be determined by the
upper and lower limits for temperature and humidity. Select Set Temperature and
Humidity in [Select Operation Type]and set the upper and lower limits for alarmgeneration in [Temperature and Humidity]. Click . The operational result is
displayed in the status bar, as shown in Figure 2-15.
Figure 2-15 Set upper and lower limits for temperature and humidity
Huawei Technologies Proprietary
2-12
-
8/13/2019 09 Site Maintenance
14/14
User ManualM900/M1800 Base Transceiver Station (BTS30) Chapter 2 Site Maintenance
With the implementation of relay operation, maintenance can startup and close
some relevant equipment. Select Relay Operation in[Select Operation Type], and
set the starting and closing of the relevant relays in Relay Operation. Click
and the operational result will be displayed, as shown in Figure 2-16.
Figure 2-16 Relay operation
Select Disable the EAC Alarm, and the alarm report will be shut down for 10
minutes. This is performed by the maintenance personnel in equipmentmaintenance to prevent the mis-generation of false alarms caused by their
operations. Select Disable the EAC Alarm in [Select Operation Type], and click
. The operational result will be displayed, as shown in Figure 2-17.
Figure 2-17 Disable the EAC alarm