PROJECT TEAM PROJECT NAME PROJECT ADDRESS © 2018 Kirksey KIRKSEY PROJECT NO. RENDERING FOR ARTISTIC REPRESENTATION ONLY 1/9/2019 4:39:12 PM C:\Users\michaell\Documents\ARCH_2017187_COMMONS_BLDG_michaell.rvt PERMIT & BID JAN 09 2019 Commons & Parking Garage 2140 Westheimer Road Houston, Texas 77098 2017187 St. Anne Catholic Community 2140 Westheimer Road Macdonald Engineering, LLC CIVIL ENGINEER Walter P Moore 1301 McKinney, Suite 1100 ME Engineers, Inc. MEP ENGINEER Commons & Parking Garage * OWNER 1604 Woodhead Street STRUCTURAL ENGINEER 4550 Post Oak Place, Suite 334 Kudela & Weinheimer LANDSCAPE ARCHITECT 7155 Old Katy Road SLR Consulting ACOUSTIC ENGINEER 6001 Savoy Drive, Suite 215 Houston, Texas 77098 www.saintanne.org Houston, Texas 77019 macdonaldengineering.com Houston, Texas 77010 walterpmoore.com Houston, Texas 77027 me-engineers.com Houston, Texas 77024 kwtexas.com Houston, Texas 77036 slrconsulting.com SACC - COMMONS BLDG & GARAGE R E G I S T E R E D A R C H I T E C T S T A T E O F T E X A S J A N I S B R A C K E T T 1 7 4 5 9 09 JANUARY 2019

Upload: others

Post on 04-Nov-2019

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

PROJECT TEAM

PROJECT NAME

PROJECT ADDRESS

© 2018 Kirksey

KIRKSEY PROJECT NO.

RENDERING FOR ARTISTIC REPRESENTATION ONLY

1/9

/20

19

4:3

9:1

2 P

MC

:\U

se

rs\m

ich

ae

ll\D

ocum

en

ts\A

RC

H_

20

17

18

7_

CO

MM

ON

S_B

LD

G_

mic

ha

ell.

rvt

PERMIT & BIDJAN 09 2019

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

St. Anne Catholic Community2140 Westheimer Road

Macdonald Engineering, LLCCIVIL ENGINEER

Walter P Moore1301 McKinney, Suite 1100

ME Engineers, Inc.MEP ENGINEER

Commons & Parking Garage

*

OWNER

1604 Woodhead Street

STRUCTURAL ENGINEER

4550 Post Oak Place, Suite 334

Kudela & WeinheimerLANDSCAPE ARCHITECT

7155 Old Katy Road

SLR ConsultingACOUSTIC ENGINEER

6001 Savoy Drive, Suite 215

Houston, Texas 77098

www.saintanne.org

Houston, Texas 77019

macdonaldengineering.com

Houston, Texas 77010

walterpmoore.com

Houston, Texas 77027

me-engineers.com

Houston, Texas 77024

kwtexas.com

Houston, Texas 77036

slrconsulting.com

SACC - COMMONS BLDG & GARAGE

REG

IS

TERED ARCHITECT

STATE OF TEXAS

JA

NIS BRACKETT

17459

09 JANUARY 2019

Page 2: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

F

FA FIRE ALARM

FC FIRE CODE

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEB FIRE EXTINGUISHER, BRACKET

FEC FIRE EXTINGUISHER, CABINET

FG ENTRANCE FLOOR GRILLES

FH FIRE HYDRANT

FIN FINISH/FINISHED

FIXT FIXTURE

FLRG FLOORING

FLR FLOOR

FLSHG FLASHING

F.P.W. FLOOD PROTECTION WALL

FL FLOW LINE

FM FACTORY MUTUAL

FND FOUNDATION

FR GL FRITTED GLASS

FRP FIBER REINFORCED PLASTIC

FRPF FIREPROOF(ING)

FSEC FOOD SERVICE EQUIPMENT CONTRACTOR

FS FULL SIZE

FTG FOOTING

FT FOOT (FEET)

FURN FURNISH

FURR FURRED/FURRING

FV FIELD VERIFY

FVC FIRE VALVE CABINET

FWC FABRIC WALL COVERING

FWP FABRIC WRAPPED WALL PANELS

GGALV GALVANIZED

GAL GALLON

GA GAUGE

GC GENERAL CONTRACTOR

GD GUARD

GEN GENERAL

GF GLASS FILM

GI GALVANIZED IRON

GL GLASS, GLAZING

GL BLK GLASS BLOCK

GMP GUARANTEED MAXIMUM PRICE

GR GRADE, GRADING

GRP GRAVEL

GRT GROUT

GSF GLAZING SURFACE FILM

GSF GROSS SQUARE FOOT

GYP GYPSUM

HHB HOSE BIBB

HC HOLLOW CORE

HDCP HANDICAPPED

HDWR HARDWARE

HD HEAD

HFS HALF FULL SIZE

HLB HORIZONTAL LOUVER BLINDS

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HORSEPOWER

HR HOUR

HT HEIGHT

HVAC HEATING/VENTILATING/

AIR CONDITIONING

HW HOT WATER

HYD HYDRANT

IID INSIDE DIAMETER

INCL INCLUDE

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

IN INCH

IPS INSIDE PIPE SIZE

JJAN JANITOR

JST JOIST

JT JOINT

LLAM LAMINATE(D)

LAV LAVATORY

LGTH LENGTH

LH LEFT HAND

LV LEVEL

LIN LINEAR

LL LIVE LOAD

LT LIGHT

LVR LOUVER

LWT LIGHTWEIGHT

MM METER

MM MILLIMETER

MACH MACHINE

MAINT MAINTENCE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEJ MASONRY EXPANSION JOINT

MEP MECHANICAL, ELECTRICAL

PLUMBING

MF METAL FINISHES

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

ML METAL LATH

MLDG MOULDING

MO MASONRY OPENING

MR MOISTURE RESISTANT

MSV MANUFACTURED STONE VENEER

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

MWP METAL WALL PANEL

NNIC NOT IN CONTRACT

NOM NOMINAL

NO. OR # NUMBER

NRA NET RENTABLE SQUARE FOOT

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

OOA OVERALL

OC ON CENTER(S)

OCD OVERHEAD COILING DOOR

OCG OVERHEAD COILING GRILLES

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED/

CONTRACTOR INSTALLED

OFF OFFICE

OFOI OWNER FURNISHED/

OWNER INSTALLED

OH OVERHEAD

OP OPERABLE PARTITION

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

O.S. OVERFLOW SCUPPER

O/A OUTSIDE AIR

P

PAC ARCHITECTURAL PRECAST CONCRETE

PART PARTITION

PC POLISHED CONCRETE

PCF POUNDS PER CUBIC FOOT

PDP PREFINISHED DECORATIVE

PANELS

PERF PERFORATED

PLAST PLASTER

PLAS PLASTIC

PLBG PLUMBING

PLWD PLYWOOD

PNL PANEL

POL POLISHED

PRKG PARKING

PR PAIR

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT

PTD PAINTED

PTS PAINTED

PVC POLYVINYL CHLORIDE

PVG PAVING

PVMT PAVEMENT

P.L. PROPERTY LINE

PL PLASTIC LAMINATE

P/C PRECAST

PFP PREFINISHED PANEL

QQT QUARRY TILE

RR RISER

RAD RADIUS

RBA RESILIENT BASE AND ACCESSORY

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REBAR REINFORCING BAR

RECEPT RECEPTION

RECEP RECEPTACLE

RECOM RECOMMENDATION

REC RECESSED

REG REGULATION

REINF REINFORCED

REQD REQUIRED

RET RETURN

REV REVISION

RE REFER TO

RF RESINOUS FLOORING

RFG ROOFING

RH RIGHT HAND

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RS ROLLER SHADE

RSF RESILIENT SHEET FLOORING

RSF RENTABLE SQUARE FOOT

RTF RESILIENT TILE FLOORING

R/AG RETURN AIR GRILLE

R/A RETURN AIR

S

SAWU SOUND ABSORBING WALL UNITS

SCHED SCHEDULE(D)

SC STAINED CONCRETE

SECT SECTION

SF SQUARE FEET

SHLV SHELVES/SHELVING

SHTHG SHEATHING

SHT SHEET

SIM SIMILAR

SKY SKYLIGHT

SMV STONE MASONRY VENEER

SPEC SPECIFICATION

SQ SQUARE

SS SOILD SURFACE

SSTL STAINLESS STEEL

STA STATION

STAB STABILIZE(D)

STC SOUND TRANSMISSION

COEFFICIENT

STC STONE COUNTERTOP

STF STONE FACING

STL STEEL

STOR STORAGE

STRUCT STRUCTURE/STRUCTURAL

SUSP SUSPENDED

SW SWITCH

S/AD SUPPLY AIR DIFFUSER

TT TREAD

TA TOILET ACCESSORY

TCOC TEXTURE COATING ON CONCRETE

TC TRAFFIC COATING

TEL TELEPHONE

TEMP TEMPERED

THK THICK(NESS)

THRES THRESHOLD

TKBD TACK BOARD

T.O. TOP OF

TOS TOP OF STEEL

TOSS TOP OF STRUCTURAL SLAB

TR TRIM (METAL EDGE TRIM)

TRANS TRANSFORMER

TS TUBE STEEL

TTC TELEPHONE TERMINAL CABINET

TUC TILT-UP CONCRETE

TV TELEVISION

TYP TYPICAL

UUL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UPH UPHOLSTERY

UR URINAL

VVAC VACUUM

VERT VERTICAL

VEST VESTIBULE

VLB VERTICAL LOUVER BLINDS

WWC WALL COVERING

WCD WALL COVERING - DRY ERASE

WDW WINDOW

WD WOOD

WDV WOOD VENEER

WF WIDE FLANGE

WFA WOOD ATHLETIC FLOORING

WFE ENGINEERED WOOD PLANK FLOORINGWH WALL HUNG

WI WROUGHT IRON

WP WALL PROTECTION

WR WATER REPELLENTS

WWF WELDED WIRE FRABIC

W.P. WORK POINT

W/I WITHIN

W/O WITHOUT

W/ WITH

XXFMR TRANSFORMER

AAB ANCHOR BOLT

AC ACOUSTICAL SEALANT

ACC ARCHITECTURAL CAST IN PLACE

CONCRETE

ACM ALUMINUM COMPOSITE METAL

ACOUS ACOUSTICAL

ADJUST ADJUSTABLE

ADJ ADJACENT

AD ACCESS DOOR

AF ACCESS FLOORING

AFF ABOVE FINISH FLOOR

AGG AGGREGATE

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANG ANGLE

ANOD ANODIZED

APPROX APPROXIMATELY

APC ACOUSTICAL PANEL CEILING

ARCH ARCHITECT/ARCHITECTURAL

ASPH ASPHALT

ATC ACRYLIC TEXTURED COATING

ATN ATTENUATION/ATTENUATING

AUTO AUTOMATIC

AUX AUXILIARY

AVE AVENUE

AVG AVERAGE

A/C AIR CONDITIONING

A/V AUDIO VISUAL

BB BASE

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BLK BLOCK

BM BEAM

BOT BOTTOM

B.O. BOTTOM OF

BR BICYCLE RACK

BRG BEARING

BRK BRICK

BRKT BRACKET

BSMT BASEMENT

BTW BETWEEN

B&B BALLED & BUR LAPPED

B-B BACK TO BACK

B.M. BENCH MARK

B/F BOTH FACES

CCAB CABINET

CB CATCH BASIN

CCTV CLOSED CIRCUIT TELEVISION

CEM CEMENT

CER CERAMIC

CFMF COLD FORMED METAL FRAMING

CFT CORK FLOOR TILE

CIP CAST IN PLACE CONCRETE

CJ CONTROL JOINT

CKBD CHALKBOARD

CLG CEILING

CLR CLEAR(ANCE)

CL CLOSET

CM CONSTRUCTION MANAGER

CMU CONCRETE MASONRY UNIT

CNTR COUNTER

COL COLUMN

COMPRESS COMPRESSIBLE

COMP COMPOSITION

CONC CONCRETE

COND CONDITION

CONF CONFERENCE

CONST CONSTRUCTION

CONTR CONTRACTOR

CONT CONTINUOUS

CORRU CORRUGATED

CORR CORRIDOR

CPS CARPET SHEET

CPT CARPET TILE

CSM CAST STONE MASONRY

CSMT CASEMENT

CTR CENTER

CTSK COUNTERSUNK

CU FT CUBIC FOOT (FEET)

CU YD CUBIC YARD

CW COLD/CHILLED WATER

C-C CENTER TO CENTER

C.O. CASED OPENING

D

D DEEP/DEPTH

DBL DOUBLE

DEFL DEFLECTION

DEFS DECORATIVE EXTERIOR FINISH

DF DRINKING FOUNTAIN

DGL DECORATIVE GLASS

DIAG DIAGONAL

DIA DIAMETER

DIM DIMENSION

DISC DISCONNECT

DISP DISPENSER

DL DEAD LOAD

DN DOWN

DR DOOR

DS DOWNSPOUT

DSC DIMENSIONAL STONE CLADDING

DTL DETAIL

DWG(S) DRAWING(S)

EEA EACH

EFOB EXTERIOR FACE OF BUILDING

EJ EXPANSION JOINT

ELAS ELASTIC (ELASTOMERIC)

ELEC ELECTRICAL

ELEV ELEVATOR

EL ELEVATION

ELAST ELASTOMERIC

EM ENTRANCE FLOOR MATS

EMER EMERGENCY

EP EXPLOSION PROOF

EQUIP EQUIPMENT

EQ EQUAL

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EW EACH WAY

EXH EXHAUST

EXIST EXISTING

EXPAN EXPANSION

EXP EXPOSED

EXT EXTERIOR

S.### SHEET NOTE - SITE

P.###

SHEET NOTE - FLOOR PLAN

R.### SHEET NOTE - REFLECTED CEILING PLAN

PW.### SHEET NOTE - POWER PLAN

F.###

SHEET NOTE - FINISH PLAN

D.### SHEET NOTE - DEMO PLAN

FN.### SHEET NOTE - FURNITURE PLAN

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

These drawings have been prepared as one coordinated set of drawings and are complimentary. What is required by one drawing is required by all of the drawings, even if a detail or component part is not identified on every sheet. Any user’s

reliance on a single or select few sheet(s) of the drawings without consideration for the information included in the entire set of drawings will be at the user’s sole risk and shall not form the basis for a request for additional compensation or time.

© 2018 Kirksey

1/9

/20

19

4:5

5:1

5 P

MC

:\U

se

rs\S

teven

\Do

cu

me

nts

\AR

CH

_2

01

71

87

_C

OM

MO

NS

_B

LD

G_

ste

ve

n@

kirksey.c

om

.rvt

A0.11

ABBREVIATIONS

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1 JAN 09 2019 PERMIT & BID

REG

IS

TERED ARCHITECT

STATE OF TEXAS

JA

NIS BRACKETT

17459

09 JANUARY 2019

Page 3: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

These drawings have been prepared as one coordinated set of drawings and are complimentary. What is required by one drawing is required by all of the drawings, even if a detail or component part is not identified on every sheet. Any user’s

reliance on a single or select few sheet(s) of the drawings without consideration for the information included in the entire set of drawings will be at the user’s sole risk and shall not form the basis for a request for additional compensation or time.

1/9

/20

19

5:2

6:4

3 P

MC

:\U

se

rs\S

teven

\Do

cu

me

nts

\AR

CH

_2

01

71

87

_C

OM

MO

NS

_B

LD

G_

ste

ve

n@

kirksey.c

om

.rvt

A0.12

SHEET INDEX

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

© 2017 Kirksey

# SHEET NAME DATE REVISION

P6.00 PLUMBING DETAILS JAN 09 2019 PERMIT & BID

P6.01 PLUMBING DETAILS JAN 09 2019 PERMIT & BID

P7.00 PLUMBING SCHEDULES JAN 09 2019 PERMIT & BID

PLUMBING - COMMONS BLDG.

1-P2.00 PLUMBING LEVEL 1 UNDERFLOOR PLAN JAN 09 2019 PERMIT & BID

1-P2.01 PLUMBING LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

1-P2.02 PLUMBING LEVEL 2 MEZZANINE FLOOR PLAN JAN 09 2019 PERMIT & BID

1-P2.03 PLUMBING ROOF PLAN JAN 09 2019 PERMIT & BID

PLUMBING - GARAGE

2-P2.00 PLUMBING LEVEL 1 UNDERFLOOR PLAN JAN 09 2019 PERMIT & BID

2-P2.01 PLUMBING LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-P2.02 PLUMBING LEVEL 2 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-P2.03 PLUMBING LEVEL 3 FLOOR PLAN JAN 09 2019 PERMIT & BID

FIRE PROTECTION

FP0.00 FIRE PROTECTION LEGEND AND DETAILS JAN 09 2019 PERMIT & BID

FIRE PROTECTION - COMMONS BLDG.

1-FP2.01 FIRE PROTECTION LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

1-FP2.02 FIRE PROTECTION LEVEL 2 MEZZANINE FLOOR PLAN JAN 09 2019 PERMIT & BID

FIRE PROTECTION - GARAGE

2-FP2.01 FIRE PROTECTION LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-FP2.02 FIRE PROTECTION MEZZANINE FLOOR PLAN JAN 09 2019 PERMIT & BID

2-FP2.03 FIRE PROTECTION LEVEL 2 FLOOR PLAN JAN 09 2019 PERMIT & BID

PARKING

PK1.00 PARKING LOT STRIPING SITE PLAN JAN 09 2019 PERMIT & BID

PK1.01 LEVEL 1 PAVEMENT MARKING PLAN JAN 09 2019 PERMIT & BID

PK1.02 LEVEL 2 PAVEMENT MARKING PLAN JAN 09 2019 PERMIT & BID

PK1.03 LEVEL 3 PAVEMENT MARKING PLAN JAN 09 2019 PERMIT & BID

PK1.20 PAVEMENT MARKING DETAILS JAN 09 2019 PERMIT & BID

PK2.01 LEVEL 1 GRAPHICS PROGRAMMING PLAN JAN 09 2019 PERMIT & BID

PK2.02 LEVEL 2 GRAPHICS PROGRAMMING PLAN JAN 09 2019 PERMIT & BID

PK2.03 LEVEL 3 GRAPHICS PROGRAMMING PLAN JAN 09 2019 PERMIT & BID

PK2.20 SIGNS & GRAPHICS SCHEDULE JAN 09 2019 PERMIT & BID

PK2.21 SIGN FACE DETAILS JAN 09 2019 PERMIT & BID

SIGNAGE

SG1.00 INTERIOR SIGNAGE TYPES JAN 09 2019 PERMIT & BID

TRAFFIC CONTROL

T1.0 KINGSTON ST. TRAFFIC CONTROL PLAN JAN 09 2019 PERMIT & BID

T1.1 SHEPHERD DR. TRAFFIC CONTROL PLAN JAN 09 2019 PERMIT & BID

# SHEET NAME DATE REVISION

2-A4.21 WALL SECTIONS BLDG B JAN 09 2019 PERMIT & BID

2-A4.22 WALL SECTIONS BLDG B JAN 09 2019 PERMIT & BID

2-A5.10 EXTERIOR PLAN DETAILS BLDG B JAN 09 2019 PERMIT & BID

2-A5.20 EXTERIOR SECTION DETAILS BLDG B JAN 09 2019 PERMIT & BID

2-A5.21 EXTERIOR SECTION DETAILS BLDG B JAN 09 2019 PERMIT & BID

2-A6.50 WINDOW TYPES AND GLAZING SCHEDULE BLDG B JAN 09 2019 PERMIT & BID

2-A7.10 STAIR PLANS AND SECTIONS BLDG B JAN 09 2019 PERMIT & BID

2-A7.11 STAIR PLANS AND SECTIONS BLDG B JAN 09 2019 PERMIT & BID

2-A7.23 STAIR DETAILS BLDG B JAN 09 2019 PERMIT & BID

2-A7.30 ELEVATOR PLANS AND SECTIONS BLDG B JAN 09 2019 PERMIT & BID

2-A7.31 ELEVATOR DETAILS BLDG B JAN 09 2019 PERMIT & BID

2-A8.10 INTERIOR ELEVATIONS BLDG B JAN 09 2019 PERMIT & BID

ARCHITECTURAL

A6.10 DOOR & FRAME TYPES, DOOR SCHEDULE AND NOTES JAN 09 2019 PERMIT & BID

A6.30 DOOR HARDWARE SPECIFICATIONS JAN 09 2019 PERMIT & BID

A6.31 DOOR HARDWARE SPECIFICATION & SCHEDULE JAN 09 2019 PERMIT & BID

A6.61 PARTITION TYPES JAN 09 2019 PERMIT & BID

A6.62 PARTITION TYPES JAN 09 2019 PERMIT & BID

A9.20 INTERIOR SECTION DETAILS JAN 09 2019 PERMIT & BID

A9.21 INTERIOR SECTION DETAILS JAN 09 2019 PERMIT & BID

A10.10 MILLWORK (LEGEND & SCHEDULES) JAN 09 2019 PERMIT & BID

A10.11 MILLWORK JAN 09 2019 PERMIT & BID

A10.12 MILLWORK JAN 09 2019 PERMIT & BID

STRUCTURAL

S1.00 GENERAL NOTES JAN 09 2019 PERMIT & BID

S1.01 GENERAL NOTES JAN 09 2019 PERMIT & BID

S1.02 SYMBOLS AND NOTATIONS JAN 09 2019 PERMIT & BID

S1.10 CONCRETE COVER AND CONCRETE MATRIX JAN 09 2019 PERMIT & BID

S2.00 FOUNDATION AND LEVEL 1 FLOOR PLAN - COMMONS BUILDING JAN 09 2019 PERMIT & BID

S2.01 MEZZANINE LOW ROOF LEVEL - COMMONS BUILDING JAN 09 2019 PERMIT & BID

S2.02 ROOF PLAN - COMMONS BUILDING JAN 09 2019 PERMIT & BID

S2.10 FOUNDATION LEVEL 1 FLOOR PLAN - GARAGE JAN 09 2019 PERMIT & BID

S2.11 LEVEL 2 FLOOR PLAN - GARAGE JAN 09 2019 PERMIT & BID

S2.12 LEVEL 3 FLOOR PLAN - GARAGE JAN 09 2019 PERMIT & BID

S2.20 PARTIAL PLANS JAN 09 2019 PERMIT & BID

S2.30 ROOF UPLIFT PLAN JAN 09 2019 PERMIT & BID

S3.00 TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.10 FOUNDATION TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.11 FOUNDATION TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.12 FOUNDATION TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.20 PRECAST CONCRETE TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.30 STEEL FRAMING TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.31 STEEL FRAMING TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.32 STEEL FRAMING TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.40 MASONRY TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S3.41 MASONRY TYPICAL DETAILS JAN 09 2019 PERMIT & BID

S4.01 BUILDING SECTIONS AND DETAILS JAN 09 2019 PERMIT & BID

S4.02 BUILDING SECTIONS AND DETAILS JAN 09 2019 PERMIT & BID

S4.03 BUILDING SECTIONS AND DETAILS JAN 09 2019 PERMIT & BID

MECHANICAL

M0.00 MECHANICAL LEGEND JAN 09 2019 PERMIT & BID

M0.01 MECHANICAL GENERAL NOTES JAN 09 2019 PERMIT & BID

M1.00 MECHANICAL SITE PLAN JAN 09 2019 PERMIT & BID

M2.00 MECHANICAL SECTION VIEWS JAN 09 2019 PERMIT & BID

MECHANICAL

1-M2.01 MECHANICAL LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

1-M2.02 MECHANICAL LEVEL 2 MEZZANINEROOF FLOOR PLAN JAN 09 2019 PERMIT & BID

2-M2.01 MECHANICAL LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-M2.02 LEVEL 2 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-M2.03 MECHANICAL LEVEL 3 FLOOR PLAN JAN 09 2019 PERMIT & BID

M6.00 MECHANICAL CONTROL DIAGRAM JAN 09 2019 PERMIT & BID

M6.01 MECHANICAL CONTROL DIAGRAM JAN 09 2019 PERMIT & BID

M6.02 MECHANICAL CONTROL DIAGRAM JAN 09 2019 PERMIT & BID

M7.00 MECHANICAL DETAILS JAN 09 2019 PERMIT & BID

M7.01 MECHANICAL DETAILS JAN 09 2019 PERMIT & BID

M7.02 MECHANICAL CODE COMPLIANCE JAN 09 2019 PERMIT & BID

M8.00 MECHANICAL SCHEDULES JAN 09 2019 PERMIT & BID

M8.01 MECHANICAL SCHEDULES JAN 09 2019 PERMIT & BID

ELECTRICAL

1-E0.01 ELECTRICAL ONE-LINE DIAGRAM & PANEL SCHEDULES JAN 09 2019 PERMIT & BID

1-E0.02 ELECTRICAL LIGHTING CONTROL SCHEDULE & CODE COMPLIANCE JAN 09 2019 PERMIT & BID

1-E5.00 ELECTRICAL SCHEDULES JAN 09 2019 PERMIT & BID

2-E0.01 ELECTRICAL ONE-LINE DIAGRAM & PANEL SCHEDULES JAN 09 2019 PERMIT & BID

2-E0.02 ELECTRICAL LIGHTING CONTROL SCHEDULE & CODE COMPLIANCE JAN 09 2019 PERMIT & BID

2-E4.00 ELECTRICAL ENLARGED PLANS JAN 09 2019 PERMIT & BID

2-E5.00 ELECTRICAL SCHEDULES JAN 09 2019 PERMIT & BID

E0.00 ELECTRICAL LEGEND JAN 09 2019 PERMIT & BID

E1.00 ELECTRICAL SITE PLAN JAN 09 2019 PERMIT & BID

E1.01 ELECTRICAL COMMONS AND GARAGE OVERALL PLAN JAN 09 2019 PERMIT & BID

E5.00 ELECTRICAL DETAILS JAN 09 2019 PERMIT & BID

E6.00 ELECTRICAL DETAILS JAN 09 2019 PERMIT & BID

E6.01 ELECTRICAL DETAILS JAN 09 2019 PERMIT & BID

ELECTRICAL - COMMONS BLDG.

1-E2.01 ELECTRICAL LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

1-E2.02 ELECTRICAL LEVEL 2 MEZZANINE FLOOR PLAN JAN 09 2019 PERMIT & BID

1-E3.01 ELECTRICAL LIGHTING LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

1-E3.02 ELECTRICAL LIGHTING LEVEL 2 MEZZANINE FLOOR PLAN JAN 09 2019 PERMIT & BID

ELECTRICAL - GARAGE

2-E2.01 ELECTRICAL LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-E2.02 ELECTRICAL LEVEL 2 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-E2.03 ELECTRICAL LEVEL 3 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-E3.01 ELECTRICAL LIGHTING LEVEL 1 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-E3.02 ELECTRICAL LIGHTING LEVEL 2 FLOOR PLAN JAN 09 2019 PERMIT & BID

2-E3.03 ELECTRICAL LIGHTING LEVEL 3 FLOOR PLAN JAN 09 2019 PERMIT & BID

PLUMBING

P0.00 PLUMBING LEGEND JAN 09 2019 PERMIT & BID

P4.00 PLUMBING ENLARGED PLANS JAN 09 2019 PERMIT & BID

P5.00 PLUMBING ISOMETRICS JAN 09 2019 PERMIT & BID

P5.01 PLUMBING ISOMETRICS JAN 09 2019 PERMIT & BID

P5.02 PLUMBING ISOMETRICS JAN 09 2019 PERMIT & BID

# SHEET NAME DATE REVISION

GENERAL

A0.00 TITLE SHEET JAN 09 2019 PERMIT & BID

A0.10 GRAPHIC STANDARDS JAN 09 2019 PERMIT & BID

A0.11 ABBREVIATIONS JAN 09 2019 PERMIT & BID

A0.12 SHEET INDEX JAN 09 2019 PERMIT & BID

A0.20 CODE INFORMATION - COMMONS BLDG A JAN 09 2019 PERMIT & BID

A0.21 CODE INFORMATION - GARAGE & MINISTRY BLDG B JAN 09 2019 PERMIT & BID

A0.50 FIRE ASSEMBLY (PARTITIONS) JAN 09 2019 PERMIT & BID

A0.51 FIRE ASSEMBLY (PARTITIONS) JAN 09 2019 PERMIT & BID

A0.60 REFERENCE (MOUNTING HEIGHTS) JAN 09 2019 PERMIT & BID

A0.61 REFERENCE (DOOR MANEUVERING CLEARANCES) JAN 09 2019 PERMIT & BID

A0.70 MASTER SCHEDULE JAN 09 2019 PERMIT & BID

A0.71 MASTER SCHEDULE JAN 09 2019 PERMIT & BID

GENERAL

1-A0.31 LIFE SAFETY PLAN LEVEL 1 BLDG A JAN 09 2019 PERMIT & BID

1-A0.32 LIFE SAFETY PLAN - EQUIPMENT LEVEL BLDG A JAN 09 2019 PERMIT & BID

2-A0.31 LIFE SAFETY PLAN - LEVEL 1 BLDG B JAN 09 2019 PERMIT & BID

2-A0.32 LIFE SAFETY PLAN - LEVEL 2 BLDG B JAN 09 2019 PERMIT & BID

2-A0.33 LIFE SAFETY PLAN - LEVEL 3 BLDG B JAN 09 2019 PERMIT & BID

CIVIL

C0.0 CIVIL OVERALL SITE PLAN JAN 09 2019 PERMIT & BID

C1.0 CIVIL SITE DEMOLITION PLAN JAN 09 2019 PERMIT & BID

C1.1 CIVIL SITE DEMOLITION PLAN JAN 09 2019 PERMIT & BID

C1.2 CIVIL SITE DEMOLITION PLAN JAN 09 2019 PERMIT & BID

C1.3 CIVIL SITE DEMOLITION PLAN JAN 09 2019 PERMIT & BID

C2.0 CIVIL SITE LAYOUT PLAN JAN 09 2019 PERMIT & BID

C2.1 CIVIL SITE LAYOUT PLAN JAN 09 2019 PERMIT & BID

C2.2 CIVIL SITE LAYOUT PLAN JAN 09 2019 PERMIT & BID

C2.3 CIVIL SITE LAYOUT PLAN JAN 09 2019 PERMIT & BID

C3.0 CIVIL SITE GRADING PLAN JAN 09 2019 PERMIT & BID

C3.1 CIVIL SITE GRADING PLAN JAN 09 2019 PERMIT & BID

C3.2 CIVIL SITE GRADING PLAN JAN 09 2019 PERMIT & BID

C3.3 CIVIL SITE GRADING PLAN JAN 09 2019 PERMIT & BID

C4.0 CIVIL SITE UTILITY PLAN JAN 09 2019 PERMIT & BID

C4.1 CIVIL SITE UTILITY PLAN JAN 09 2019 PERMIT & BID

C4.2 CIVIL SITE UTILITY PLAN JAN 09 2019 PERMIT & BID

C4.3 CIVIL SITE UTILITY PLAN JAN 09 2019 PERMIT & BID

C5.0 CIVIL GENERAL NOTES JAN 09 2019 PERMIT & BID

C5.1 CIVIL DETAILS JAN 09 2019 PERMIT & BID

C5.2 CIVIL DETAILS JAN 09 2019 PERMIT & BID

C5.3 CIVIL DETAILS SWQMP DETAILS JAN 09 2019 PERMIT & BID

C5.4 CIVIL DETAILS JAN 09 2019 PERMIT & BID

C6.0 CIVIL SWPPP JAN 09 2019 PERMIT & BID

C6.1 CIVIL SWPPP DETAILS JAN 09 2019 PERMIT & BID

C7.0 CIVIL SITE DRAINAGE AREA MAP JAN 09 2019 PERMIT & BID

C7.1 CIVIL SITE DRAINAGE AREA CALCULATIONS JAN 09 2019 PERMIT & BID

C8.0 CIVIL SWQMP JAN 09 2019 PERMIT & BID

LANDSCAPE

L1.01 LANDSCAPE MATERIALS PLAN JAN 09 2019 PERMIT & BID

L1.02 LANDSCAPE MATERIALS PLAN JAN 09 2019 PERMIT & BID

L1.03 LANDSCAPE MATERIALS PLAN JAN 09 2019 PERMIT & BID

L2.01 CONSTRUCTION DETAIL JAN 09 2019 PERMIT & BID

L2.02 CONSTRUCTION DETAIL JAN 09 2019 PERMIT & BID

L2.03 CONSTRUCTION DETAIL JAN 09 2019 PERMIT & BID

L3.01 LANDSCAPE PLAN JAN 09 2019 PERMIT & BID

L3.02 LANDSCAPE PLAN JAN 09 2019 PERMIT & BID

L3.03 LANDSCAPE PLAN AND DETAILS JAN 09 2019 PERMIT & BID

L3.04 LANDSCAPE PLAN AND DETAILS JAN 09 2019 PERMIT & BID

ARCHITECTURAL - COMMONS BLDG

1-A1.20 OVERALL SITE PLAN JAN 09 2019 PERMIT & BID

1-A2.31 FLOOR PLAN LEVEL 1 BLDG A JAN 09 2019 PERMIT & BID

1-A2.32 FLOOR PLAN EQUIPMENT LEVEL BLDG A JAN 09 2019 PERMIT & BID

1-A2.33 ROOF PLAN BLDG A JAN 09 2019 PERMIT & BID

1-A2.41 REFLECTED CEILING PLAN LEVEL 1 AND EQUIPMENT LEVEL BLDG A JAN 09 2019 PERMIT & BID

1-A2.61 FINISH PLAN BLDG A JAN 09 2019 PERMIT & BID

1-A2.70 ENLARGED PLANS BLDG A JAN 09 2019 PERMIT & BID

1-A2.80 RESTROOM PLANS BLDG A JAN 09 2019 PERMIT & BID

1-A2.81 RESTROOM PLANS BLDG A JAN 09 2019 PERMIT & BID

1-A2.82 RESTROOM PLANS BLDG A JAN 09 2019 PERMIT & BID

1-A2.83 RESTROOM PLANS BLDG A JAN 09 2019 PERMIT & BID

1-A3.10 ELEVATIONS BLDG A JAN 09 2019 PERMIT & BID

1-A3.11 ELEVATIONS BLDG A JAN 09 2019 PERMIT & BID

1-A4.10 BUILDING SECTIONS BLDG A JAN 09 2019 PERMIT & BID

1-A4.11 BUILDING SECTIONS BLDG A JAN 09 2019 PERMIT & BID

1-A4.20 WALL SECTIONS BLDG A JAN 09 2019 PERMIT & BID

1-A4.21 WALL SECTIONS BLDG A JAN 09 2019 PERMIT & BID

1-A4.22 WALL SECTIONS BLDG A JAN 09 2019 PERMIT & BID

1-A4.23 WALL SECTIONS BLDG A JAN 09 2019 PERMIT & BID

1-A5.10 EXTERIOR PLAN DETAILS BLDG A JAN 09 2019 PERMIT & BID

1-A5.20 EXTERIOR SECTION DETAILS BLDG A JAN 09 2019 PERMIT & BID

1-A5.21 EXTERIOR SECTION DETAILS BLDG A JAN 09 2019 PERMIT & BID

1-A5.30 ROOF DETAILS BLDG A JAN 09 2019 PERMIT & BID

1-A6.50 WINDOW TYPES AND GLAZING SCHEDULE BLDG A JAN 09 2019 PERMIT & BID

1-A7.10 STAIR PLANS AND SECTIONS BLDG A JAN 09 2019 PERMIT & BID

1-A7.20 STAIR DETAILS BLDG A JAN 09 2019 PERMIT & BID

1-A8.10 INTERIOR ELEVATIONS BLDG A JAN 09 2019 PERMIT & BID

1-A8.11 INTERIOR ELEVATIONS BLDG A JAN 09 2019 PERMIT & BID

1-A8.12 INTERIOR ELEVATIONS BLDG A JAN 09 2019 PERMIT & BID

1-A9.10 INTERIOR PLAN DETAILS BLDG A JAN 09 2019 PERMIT & BID

ARCHITECTURAL - GARAGE

2-A1.40 SITE CANOPIES PLANS & DETAILS JAN 09 2019 PERMIT & BID

2-A2.31 FLOOR PLAN LEVEL 1 BLDG B JAN 09 2019 PERMIT & BID

2-A2.32 FLOOR PLAN LEVEL 2 BLDG B JAN 09 2019 PERMIT & BID

2-A2.33 FLOOR PLAN LEVEL 3 BLDG B JAN 09 2019 PERMIT & BID

2-A2.41 REFLECTED CEILING PLAN LEVEL 1 BLDG B JAN 09 2019 PERMIT & BID

2-A2.42 REFLECTED CEILING PLAN LEVEL 2 BLDG B JAN 09 2019 PERMIT & BID

2-A2.43 REFLECTED CEILING PLAN LEVEL 3 BLDG B JAN 09 2019 PERMIT & BID

2-A2.61 FINISH PLAN LEVEL 1 BLDG B JAN 09 2019 PERMIT & BID

2-A2.70 ENLARGED FLOOR PLANS BLDG B JAN 09 2019 PERMIT & BID

2-A2.71 ENLARGED RCP & FINISH PLAN BLDG B JAN 09 2019 PERMIT & BID

2-A2.80 RESTROOM PLANS BLDG B JAN 09 2019 PERMIT & BID

2-A3.10 EXTERIOR ELEVATIONS BLDG B JAN 09 2019 PERMIT & BID

2-A3.11 EXTERIOR ELEVATIONS BLDG B JAN 09 2019 PERMIT & BID

2-A4.10 BUILDING SECTIONS BLDG B JAN 09 2019 PERMIT & BID

2-A4.20 WALL SECTIONS BLDG B JAN 09 2019 PERMIT & BID

1 JAN 09 2019 PERMIT & BID

REG

IS

TERED ARCHITECT

STATE OF TEXAS

JA

NIS BRACKETT

17459

09 JANUARY 2019

Page 4: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

DUCTWORK

DUCT MOUNTED SMOKE DETECTOR

FIRE DAMPER

SMOKE DAMPER

FIRE/SMOKE DAMPER

MOTORIZED DAMPER

BACKDRAFT DAMPER

TRANSITION:RECTANGULAR TO ROUND

ROUND DUCT UP

CONICAL TAP

RECTANGULAR BRANCH TAP

SECTION NO.

SECTION VIEW SHEET NO.

DETAIL DESIGNATION

POWERED EQUIPMENT DESIGNATION

NON POWERED EQUIPMENT DESIGNATION

BASEBOARD EQUIPMENT DESIGNATION

SHEET KEY NOTES

INDICATES TYPE OF EQUIPMENT

INDICATES UNIT NUMBER WITHIN AREA

BUILDING

C - COMMONSG - GARAGE

PIPING SYMBOLS

PRESSURE/TEMPERATURE PORT TAPS

CONCENTRIC REDUCER

ECCENTRIC REDUCER

EXPANSION JOINT

THERMOMETER W/ THERMOWELL

UNION

AIR VENT

FLEXIBLE PIPE CONNECTOR

FLOW SWITCH

PRESSURE SWITCH

P&T

CR

ER

EJ

U

T

FS

PS

AV

FC

PRESSURE GAUGE W/ GAUGE COCK

ELBOW UP

ELBOW DOWN

TEE UP

TEE DOWN

ISOLATION VALVE, RE: SPECS

PG

IV

OUTSIDE STEM AND YOKE

OS&Y

DRAIN VALVE W/ HOSE END CONNECTION

DV

PIPE CAP OR PLUG

ABBREVIATIONSYMBOL DESCRIPTION

BALL VALVE W/ HOSE CONNECTION

CHECK VALVE WITH INDICATION OF FLOW DIRECTION

PRESSURE REDUCING VALVE

AUTO FLOW CONTROL VALVE W/ TEST PORTS

CIRCUIT SETTER OR BALANCING VALVE

GLOBE VALVE (STRAIGHT PATTERN)

GLOBE VALVE (ANGLE PATTERN)

BUTTERFLY VALVE

CV

PRV

FCV

GLV

BFV

CS,BV

GLV

BALL VALVE

AUTOMATIC TEMPERATURE CONTROL VALVE, 2-WAY

AUTOMATIC TEMPERATURE CONTROL VALVE, 3-WAY

BALANCING VALVE

TEMPERATURE/PRESSURE RELIEF VALVE

STRAINER W/ BLOW-OFF & CAPPED HOSE END CONNECTION

BV

TCV

TCV

BV

TMP

STR

STEAM TRAPST

VALVE IN RISER

PIPING TYPES

CHILLED WATER SUPPLY

CHILLED WATER RETURN

HEATING WATER SUPPLY

HEATING WATER RETURN

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

CONDENSATE DRAIN

HIGH PRESSURE STEAM SUPPLY

MEDIUM PRESSURE STEAM SUPPLY

LOW PRESSURE STEAM SUPPLY

CHS

CHR

HWS

HWR

CWS

CWR

MPS

LPS

D

HPS

HIGH PRESSURE CONDENSATE RETURN

MEDIUM PRESSURE CONDENSATE RETURN

LOW PRESSURE CONDENSATE RETURN

REFRIGERANT SUCTION

REFRIGERANT LIQUID

CONTROL AIR (PNEUMATIC)

CHS

CHR

HWS

HWR

CWS

CWR

MPS

LPS

D

HPS

HPRHPR

MPRMPR

LPRLPR

RSRS

RLRL

AA

BOILER BLOW DOWN

BDBD

BOILER FEEDBFBF

BLOW OFFBOBO

CHEMICAL FEEDER

CFCF

PROCESS COOLING WATER SUPPLY/RETURN

PCS/RPCS/R

HIGH TEMP. HOT WATER SUPPLY/RETURN

HTWS/RHTWS/R

PRIMARY OR DISTRICT HEATING WATER SUPPLY/RETURN

PHWS/RPHWS/R

PRIMARY OR DISTRICT CHILLED WATER SUPPLY/RETURN

PCHS/RPCHS/R

PUMPED CONDENSATE RETURN

PRPR

EXISTING PIPING(E)(E)

EXISTING PIPING TO BE REMOVED

(E)(E)

REFRIGERANT HOT GAS

RHGRHG

SINGLE LINE PIPING(UP TO 2")

DOUBLE LINE PIPING(2" AND ABOVE)

PIPETYPE

MISCELLANEOUS

SUPPLY DIFFUSER-4-WAY THROW

SUPPLY DIFFUSER-3-WAY THROW

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

UC

POINT OF DISCONNECTION

UNDERCUT DOOR (UNDER ARCH. SECTION)

D/L DOOR LOUVER (UNDER ARCH. SECTION)

L/DLOUVER DOOR FULL HEIGHT. (UNDER ARCH. SECTION)

ARROW INDICATES DIRECTION OF FLOWEXTERIOR WALL LOUVER (UNDER ARCH. SECTION)

SUPPLY DIFFUSER-2-WAY THROW

SUPPLY DIFFUSER-1-WAY THROW

EQUIPMENT DESIGNATION

POINT OF CONN. (CONN. NEW TO EXISTING)

(QTY)

DIFFUSER TYPE

SUPPLY DIFFUSER

ROUND DUCT DOWN

SUPPLY OR OUTSIDE AIR DOWN

NEW DUCTWORK

20"x16"

DUCT DIMENSIONS (WIDTH x HEIGHT)

TURNING VANES

SPLITTER DAMPER

TRANSITION-RECT. TO RECT. OR

ROUND TO ROUND

CONICAL SPIN-IN FITTING W/

MANUAL VOLUME DAMPER

LOW PRESSURE FLEXIBLE DUCT

SUPPLY SLOT DIFFUSER

UP DN

RETURN DIFFUSER

RISE IN DIRECTION OF

AIRFLOWRETURN OR RELIEF AIR UP

EXHAUST AIR UP EXHAUST DIFFUSER

DROP IN DIRECTION OF AIRFLOW

RETURN OR RELIEF AIR DN

EXHAUST AIR DN

FITTINGS:

EJ

FS

PS

SSV SOLENOID VALVE

FC

F

S

F/S

M

B

1

A101

SIM

A

M1-01

AHU

1.01

VAV

1.01

TYPE

LENGTH

12"

AHU

C-1

S

ASIZE

CFM

EXHAUST DIFFUSER

RETURN DIFFUSER

H

CEILING ACCESS PANEL

FLEXIBLE DUCT CONNECTION

HUMIDIFIER

RETURN/EXHAUST AIR FLOW SYMBOL

SUPPLY AIR FLOW SYMBOL

HEAT TRACE

EXISTING DIFFUSER

EXISTING DUCTWORK TO BE REMOVED

EXISTING DUCTWORK

A AIR (COMPRESSED)ABV ABOVEA/C AIR CONDITIONINGAC ALTERNATING CURRENT

AIR COMPRESSORACCH AIR COOLED CHILLERACCU AIR COOLED CONDENSING UNITAD ACCESS DOOR

AREA DRAINADJ ADJUSTABLEAF AIR FILTERAFC ABOVE FINISHED CEILINGAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHU AIR HANDLING UNITAL ALUMINUMAMB AMBIENTAP ACCESS PANELAPD AIR PRESSURE DROPARI AMERICAN REFRIGERANT INSTITUTEARCH ARCHITECTAS AIR SEPARATORASHRAE AMERICAN SOCIETY OF HEATING AND REFRIGERATION ENGINEERSASME AMERICAN SOCIETY OF MECHANICAL ENGINEERSASTM AMERICAN SOCIETY OF TESTING AND MATERIALSAV ACID VENT

AIR VENTAVG AVERAGEAW ACID WASTEAWS AMERICAN WELDING SOCIETYAUX AUXILIARY

B BOILERBC BELOW COUNTERB/C BACK OF CURBBFV BUTTERFLY VALVEBH BOX HYDRANTBHP BRAKE HORSEPOWERBLDG BUILDINGBM BENCHMARKBOD BOTTOM OF DUCT (AFF)BOF BOTTOM OF FOOTINGBOS BOTTOM OF STRUCTUREBT BATH TUB

BREAK TANKBTU BRITISH THERMAL UNITBV BALL VALVEBWV BACK WATER VALVE

C CELSIUSCAB CABINETCAV CONSTANT AIR VOLUMECB CATCH BASINCC COOLING COILCD CONDENSATE DRAIN LINECFH CUBIC FEET PER HOURCFM CUBIC FEET PER MINUTECFS CUBIC FEET PER SECONDCI CAST IRONCIRC CIRCULATINGCL CENTERLINECLG CEILINGCLR CLEARCMP CORRIGATED METAL PIPECMU CONCRETE MASONRY UNITCPI CAST IRON PIPE INSTITUTECPVC CHLORINATED POLYVINYL CHLORIDECO CLEANOUTCOL COLUMNCOMB COMBINATIONCOMP COMPRESSORCON CONVERTERCONC CONCRETE

CONCENTRICCOND CONDENSER

CONDENSATECONN CONNECTIONCONT CONTINUOUS

CONTINUATIONCONTR CONTROLLER

CONTRACTORCOP COEFFICIENT OF PERFORMANCECRAC COMPUTER ROOM A/C UNITCRT CATHODE RAY TUBECRU CONDENSATE RETURN UNITCT COOLING TOWERCTR CENTERCU COPPERCW COLD WATERCWP CONDENSER WATER PUMPCWR CONDENSER WATER RETURNCWS CONDENSER WATER SUPPLYCV CONSTANT VOLUME

dB DECIBELDB DRY-BULBDC DOUBLE DUCT CONSTANT VOLUME

DIRECT CURRENTDDC DIRECT DIGITAL CONTROLDESIG DESIGNATIONDEFL DEFLECTIONDTL DETAILDF DRINKING FOUNTAINDIA DIAMETERDIFF DIFFUSERDIM DIMENSIONDISC DISCONNECTDN DOWNDP DISCHARGE PLENUMDPR DAMPERDS DOUNSPOUT

DOUBLE SUCTIONDV DOUBLE DUCT VAVDW DISHWASHERDWG DRAWINGDWH DOMESTIC WATER HEATERDWP DOMESTIC WATER PUMPDX DIRECT EXPANSION

(E) EXISTINGEA EACHEAT ENTERING AIR TEMPERATUREEC ELECTRICAL CONTRACTORECC ECCENTRICEDB ENTERING DRY BULBEDF ELECTRIC DRINKING FOUNTAINEDH ELECTRIC DUCT HEATER

EDR EFFECTIVE DIRECT RADIATIONEER ENERGY EFFICIENCY RATIOEF EXHAUST FANEFF EFFICIENCYEJ EXPANSION JOINTEL ELEVATIONEMRG EMERGENCYENCL ENCLOSUREENGR ENGINEERENT ENTERINGES END SUCTION

EMERGENCY SHOWERESP EXTERNAL STATIC PRESSUREET EXPANSION TANKETR EXISTING TO REMAINEVAP EVAPORATOREWB ENTERING WET BULBEWT ENTERING WATER TEMPERATUREEX EXPLOSION PROOFEXT EXTERNALEXTG EXISTING

F DEGREE FAHRENHEITFBO FURNISHED BY OTHERSFCO FLOOR CLEAN OUTFCS FLOOR CONTROL SWITCHFCU FAN COIL UNITFD FLOOR DRAIN

FIRE DAMPERFDS FIRE DEPARTMENT SIAMESEFDV FIRE DEPARTMENT VALVEFG FIBERGLASSFF FINAL FILTERFH FIRE HYDRANTFHC FIRE HOSE CABINETFHR FIRE HOSE RACKFIXT FIXTUREFLA FULL LOAD AMPSFLEX FLEXIBLEFL FLOW LINESFLR FLOORFP FAN POWERED MIXING BOX

FIRE PUMPFPI FINS PER INCHFPM FEET PER MINUTEFRIC FRICTIONFRZR FREEZERFS FLOW SWITCH

FIRE SPRINKLERFSK FLOOR SINKFT FOOT

FEETFT WC FEET, WATER COLUMNFUT FUTURE

G GASGA GAUGEGAL GALLONGALV GALVANIZEDGC GENERAL CONTRACTORGLV GLOBE VALVEGND GROUNDGPD GALLONS PER DAYGPM GALLONS PER MINUTEGSH GRAND SENSIBLE HEATGV GATE VALVE

HB HOSE BIBBHC HEATING COILHD HEAD

HUB DRAINHF HUMIDIFIERHORIZ HORIZONTALHP HORSEPOWER

HALON PANELHPU HEAT PUMP UNITHKP HOUSEKEEPING PADHSC HORIZONTAL SPLIT CASEHSTAT HUMIDISTATHT HEIGHTHTG HEATINGHTR HEATERHU HUMIDIFIER SECTIONHW HOT WATERHWC HOT WATER CIRCULATORHWP HOT WATER PUMPHWR HOT WATER RETURNHWS HOT WATER SUPPLYHX HEAT EXCHANGERHZ HERTZ

ID INSIDE DIAMTERIE INVERT ELEVATIONIH INFRARED HEATERIN INCHIN WC INCH, WATER COLUMNINSUL INSULATIONINT INTERNAL

INTERIORIW INDIRECT WASTE

JB JUNCTION BOXJP JOCKEY PUMP

KEC KITCHEN EQUIPMENT CONTRACTORKO` KNOCKOUTKVA KILOVOLT AMPSKW KILOWATT

L LENGTHLAT LEAVING AIR TEMPERATURELAV LAVATORYLBS POUNDSLBS/HR POUNDS PER HOURLF LINEAR FEETLP LOW PRESSURELRA LOCKED ROTOR AMPSLVG LEAVINGLVL LEVELLWB LEAVING WET BULBLWCO LOW WATER CUT OFFLWT LEAVING WATER TEMPERATURE

MA MAKE-UP AIRMAT MIXED AIR TEMPERATUREMAX MAXIMUMMBH THOUSAND BTUHMC MECHANICAL CONTRACTORMCA MINIMUM CIRCUIT AMPACITYMCC MOTOR CONTROL CENTERMECH MECHANICALMFR MANUFACTURERMH MANHOLEMI MALLEABLE IRONMIN MINIMUMMOCP MAXIMUM OVER CURRENT PROTECTIONMP MEDIUM PRESSUREMS MOP SINKMTD MOUNTEDMTL METALMU MAKE-UPMUA MAKE-UP AIR UNITMVD MANUAL VOLUME DAMPER

(N) NEWNC NORMALLY CLOSEDNFP NATIONAL FIRE PROTECTION ASSOCIATIONNIC NOT IN CONTRACTNO NORMALLY OPENNO NUMBERNTS NOT TO SCALE

OA OUTSIDE AIROAF OUTSIDE AIR FANOAHU OUTSIDE AIR HANDLING UNITOBD OPPOSED BLADE DAMPEROC ON CENTEROD OUTSIDE DIAMETER

OVERFLOW DRAINOFCU OUTSIDE AIR FAN COIL UNITOPG OPENINGOS&Y OPEN STEM AND YOLK

P PUMPPLUMBING EQUIPMENT

PC PLUMBING CONTRACTORPCR PUMPED CONDENSATE RETURNPD PRESSURE DROP

PLANTER DRAINPF PRE-FILTERPH PHASE

POST HYDRANTPIV POST INDICATOR VALVEPLBG PLUMBINGPNEU PNEUMATICPNL PANELPNTH PENTHOUSEPP POLYPROPYLENEPPM PARTS PER MILLIONPRESS PRESSUREPRI PRIMARYPRS PRIMARY REDUCING STATIONPRV PRESSURE REDUCING VALVEPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPSIG POUNDS PER SQUARE INCH, GAUGEPT PLUMBING TRIMPV PLUG VALVEPVC POLYVINYL CHLORIDEPWL SOUND POWER LEVEL

QTY QUANTITY

(R) REMOVERELOCATE

RA RETURN AIRRAD REFRIGERATED AIR DRYERRAF RETURN AIR FANRAG RETURN AIR GRILLERAT RETURN AIR TEMPERATURERCP REFLECTED CEILING PLAN

REINFORCED CONCRETE PIPERD ROOF DRAINRE REFERENCE

REFERRECIRC RECIRCULATERED REDUCERREFR REFRIGERATORREG REGISTERREINF REINFORCINGREQD REQUIREDREV REVISION

REVISERF RETURN FANRH RELATIVE HUMIDITYRHG REFRIGERANT HOT GASRKVA RUNNING KILOVOLT AMPSRKW RUNNING KILOWATTSRL REFRIGERANT LIQUIDRLA RUNNING LOAD AMPSRM ROOM

REFRIGERANT MACHINERPM REVOLUTIONS PER MINUTERS REFRIGERANT SUCTIONRTU ROOFTOP UNITRV RELIEF VALVE

SA SUPPLY AIRSAF SUPPLY AIR FANSAG SUPPLY AIR GRILLESAN SANITARY SEWERSAR SUPPLY AIR REGISTERSCHED SCHEDULESCFM STANDARD AIR CUBIC FEET PER MINUTESCR SILICON CONTROLLED RECTIFIERSD STORM DRAINSE SEWAGE EJECTORSEC SECONDARYSECT SECTIONSENS SENSIBLESF SQUARE FEET

SFCS SPRINKLER FLOOR CONTROL STATIONSH SHOWERSHT SHEETSIM SIMILARSK SINKSKVA STARTING KILOVOLT AMPSSKW STARTING KILOWATTSSM SHEET METALSP STATIC PRESSURE

SUMP PUMPSPEC SPECIFICATIONSPR SPRINKLERSQ SQUARESS STAINLESS STEEL

SERVICE SINKSSD SUBSURFACE DRAINSSFU SANITARY SEWER FIXTURE UNITSSSSC SOLID STATE SPEED CONTROLSTD STANDARDSTL STEELSTR STRAINERSURF SURFACESUSP SUSPENDSV SANITARY VENTST SOUND TRAP

TC TEMPERATURE CONTROLTD TRENCH DRAINTDH TOTAL DYNAMIC HEADTF TRANSFER FANTG TRANSFER GRILLETH BLK THRUST BLOCKTOD TOP OF DUCT (AFF)TOP TOP OF PIPE (AFF)TP TRAP PRIMERTPD TRAP PRIMER DEVICETSP TOTAL STATIC PRESSURETSTAT THERMOSTATTYP TYPICAL

U URINALU/F UNDERFLOORU/S UNDERSLABUCD UNDERCUT DOORUG UNDERGROUNDUH UNIT HEATERUL UNDERWRITERS LABORATORIESUNO UNLESS NOTED OTHERWISEUTR UP THROUGH ROOF

V VOLT, VENTVA VOLT-AMPEREVAC VACUUMVAV VARIABLE AIR VOLUMEVB VALVE BOX

VACUUM BREAKERVCP VITRIFIED CLAY PIPEVD VOLUME DAMPERVEL VELOCITYVERT VERTICALVFD VARIABLE FREUENCY DRIVEVIB VALVE IN BOXVOV VALVE ON VERTICALVP VACUUM PUMPVR VARIABLE AIR VOLUME REHEATVSD VARIABLE SPEED DRIVEVTR VENT THROUGH ROOF

W WATT, WASTE, WIDTHW/ WITHW/O WITHOUTWB WETBULBWC WATER CLOSETWCO WALL CLEANOUTWF WATER FILTERWH WALL HYDRANTWM WATER METERWP WEATHERPROOFWPD WATER PRESSURE DROPWWF WELDED WIRE FABRICWT WATER TIGHT

WEIGHT

Y YARD HYDRANT

Z ZONE

ABBREVIATIONS:ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION

B

A

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

Y

Z

EXISTING THERMOSTAT

NEW THERMOSTAT

SPACE TEMPERATURE SENSOR

SPACE HUMIDISTAT

SPACE HUMIDITY SENSOR

SPACE PRESSURE SENSOR

CARBON DIOXIDE SENSOR

CARBON MONOXIDE SENSOR

(E)T

T

TS

H

HS

PS

CD

CO

NITROGEN DIOXIDE SENSOR ND

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 9

:33

:55

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M0.00

MECHANICAL LEGEND

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

JAN 09, 2019 PERMIT & BID

01-09-2019

MECH SHEET LIST

SheetNumber Sheet Name

M0.00 MECHANICAL LEGEND

M0.01 MECHANICAL GENERAL NOTES

M1.00 MECHANICAL SITE PLAN

1-M2.01 MECHANICAL LEVEL 1 FLOOR PLAN

1-M2.02 MECHANICAL LEVEL 2 MEZZANINE/ROOF FLOOR PLAN

2-M2.01 MECHANICAL LEVEL 1 FLOOR PLAN

2-M2.02 MECHANICAL LEVEL 2 FLOOR PLAN

2-M2.03 MECHANICAL LEVEL 3 FLOOR PLAN

M2.00 MECHANICAL SECTION VIEWS

M6.00 MECHANICAL CONTROL DIAGRAM

M6.01 MECHANICAL CONTROL DIAGRAM

M6.02 MECHANICAL CONTROL DIAGRAM

M7.00 MECHANICAL DETAILS

M7.01 MECHANICAL DETAILS

M7.02 MECHANICAL CODE COMPLIANCE

M8.00 MECHANICAL SCHEDULES

M8.01 MECHANICAL SCHEDULES

Page 5: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

GENERAL MECHANICAL CONTRACT REQUIREMENTS:

GENERAL:

1. UNLESS OTHERWISE NOTED, THE WORK DESCRIBED ON THE PLANS AND SPECIFICATIONS SHALL INCLUDE THE FURNISHING AND INSTALLATION OF ALL LABOR AND MATERIALS NECESSARY FOR COMPLETE AND OPERATIONAL HVAC, FIRE PROTECTION AND PLUMBING SYSTEMS. CONTRACTOR SHALL FURNISH THESE EVEN IF ITEMS REQUIRED TO ACHIEVE THIS (I.E. OFFSETS, ISOLATION AND BALANCING DEVICES, MAINTENANCE CLEARANCES, ETC.) ARE NOT SPECIFICALLY SHOWN.

2. DATA GIVEN ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED. ABSOLUTE ACCURACY IS NOT GUARANTEED AND THE CONTRACTOR SHALL OBTAIN AND VERIFY EXACT LOCATIONS, MEASUREMENTS, LEVELS, SPACE REQUIREMENTS, POTENTIAL CONFLICTS WITH OTHER TRADES, ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT HIS WORK TO THE ACTUAL CONDITIONS OF THE JOB.

3. THE DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND SHALL NOT BE SCALED. THEY SHOW CERTAIN PHYSICAL RELATIONSHIPS WHICH MUST BE ESTABLISHED WITHIN THE DIVISION 21,22 AND 23 WORK AND ITS INTERFACE WITH OTHER WORK. ESTABLISHING THIS RELATIONSHIP IN THE FIELD IS THE EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR. THIS DIVISION SHALL COORDINATE ITS WORK WITH ALL DIVISIONS OF THE WORK AND ADJUST ITS WORK AS REQUIRED BY THE ACTUAL CONDITIONS OF THE PROJECT.

A. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING A BID TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THE PROJECT. NO EXTRAS WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS.

B. CERTAIN SYSTEMS REQUIRE ENGINEERING OF INSTALLATION DETAILS BY CONTRACTOR. UNLESS FULLY DETAILED IN THE CONTRACT DOCUMENTS, SUCH ENGINEERING IS THE EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR.

C. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHERE CLEARANCES ARE LIMITED, AND WHERE INSTALLATION DRAWINGS OR SCHEMATICS, "CONSTRUCTION DRAWINGS", OR COORDINATION DRAWINGS MAY BE REQUIRED IN ACCORDANCE WITH, OR IN EXCESS OF, THOSE REQUIRED BY THE SPECIFICATIONS. THE CONTRACTOR SHALL PREPARE ALL SUCH COORDINATION DRAWINGS AS PART OF THE BASE CONTRACT. SUCH DRAWINGS MAY BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR RECORD AND COMMENT. ANY WORK INSTALLED WITHOUT APPROVED COORDINATION DRAWINGS IS DONE AT THE CONTRACTOR'S RISK.

4. THESE NOTES ONLY SUPPLEMENT, AND DO NOT REPLACE, THE SPECIFICATIONS.

5. DEFINITIONS AND TERMINOLOGY

A. THE DEFINITIONS OF DIVISION 1 AND THE GENERAL CONDITIONS OF THIS SPECIFICATION ALSO APPLY TO THE DIVISION 21,22 AND 23 CONTRACT DOCUMENTS.

B. "CONTRACT DOCUMENTS" CONSTITUTE THE DRAWINGS, SPECIFICATIONS, GENERAL CONDITIONS, PROJECT MANUALS, ETC., PREPARED BY ENGINEER (OR OTHER DESIGN PROFESSIONAL IN ASSOCIATION WITH ENGINEER) FOR CONTRACTOR'S BID OR CONTRACTOR'S NEGOTIATIONS WITH THE OWNER. THE DIVISION 21,22 AND 23 DRAWINGS AND SPECIFICATIONS PREPARED BY THE ENGINEER ARE NOT CONSTRUCTION DOCUMENTS.

C. "CONSTRUCTION DOCUMENTS", "CONSTRUCTION DRAWINGS", AND SIMILAR TERMS FOR DIVISION 21,22 AND 23 WORK REFER TO INSTALLATION DIAGRAMS, SHOP DRAWINGS AND COORDINATION DRAWINGS PREPARED BY THE CONTRACTOR USING THE DESIGN INTENT INDICATED ON THE ENGINEER'S CONTRACT DOCUMENTS. THESE SPECIFICATIONS DETAIL THE CONTRACTOR'S RESPONSIBILITY FOR "ENGINEERING BY CONTRACTOR" AND FOR PREPARATION OF CONSTRUCTION DOCUMENTS.

D. "(N)" INDICATES "NEW" EQUIPMENT TO BE PROVIDED UNDER THIS CONTRACT.

E. "(E)" INDICATES "EXISTING" EQUIPMENT ON SITE WHICH MAY OR MAY NOT NEED TO BE RELOCATED AS A PART OF THIS WORK.

F. "(R)" INDICATES EXISTING EQUIPMENT TO BE RELOCATED AS PART OF THIS WORK.

G. "FURNISH" MEANS TO "SUPPLY" AND USUALLY REFERS TO AN ITEM OF EQUIPMENT.

H. "INSTALL" MEANS TO "SET IN PLACE, CONNECT AND PLACE IN FULL OPERATIONAL ORDER".

I. "PROVIDE" MEANS TO "FURNISH AND INSTALL".

J. "EQUIVALENT" MEANS "MEETS THE SPECIFICATIONS OF THE REFERENCE PRODUCT OR ITEM IN ALL SIGNIFICANT ASPECTS." SIGNIFICANT ASPECTS SHALL BE AS DETERMINED BY THE ARCHITECT/ENGINEER.

K. "WORK BY OTHER(S) DIVISIONS"; "RE: XX DIVISION", AND SIMILAR EXPRESSIONS MEANS WORK TO BE PERFORMED UNDER THE CONTRACT DOCUMENTS, BUT NOT NECESSARILY UNDER THE DIVISION OR SECTION OF THE WORK ON WHICH THE NOTE APPEARS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO COORDINATE THE WORK OF THE CONTRACT BETWEEN HIS/HER SUPPLIERS, SUBCONTRACTORS AND EMPLOYEES. IF CLARIFICATION IS REQUIRED, CONSULT ARCHITECT/ENGINEER BEFORE SUBMITTING BID.

L. BY INFERENCE, ANY REFERENCE TO A "CONTRACTOR" OR "SUB- CONTRACTOR" MEANS THE ENTITY WHICH HAS CONTRACTED WITH THE OWNER FOR THE WORK OF THE CONTRACT DOCUMENTS.

M. "ENGINEER" MEANS THE DESIGN PROFESSIONAL FIRM WHICH HAS PREPARED THESE CONTRACT DOCUMENTS. ALL QUESTIONS, SUBMITTALS, ETC. OF THIS DIVISION SHALL BE ROUTED THROUGH THE ARCHITECT TO THE ENGINEER (THROUGH PROPER CONTRACTUAL CHANNELS).

EXISTING BUILDING: 1. THE CONTRACTOR'S ATTENTION IS CALLED TO THE FACT THAT THE EXISTING BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONSTRUCTION. CONTINUED OPERATION OF THE FACILITY SHALL NOT BE HINDERED BY THIS WORK. THE CONTRACTOR SHALL ACCOUNT FOR ALL ADDITIONAL COSTS WHICH MAY BE INCURRED BY HIM DUE TO THE DIFFICULTY OF WORKING OVER AND AROUND EMPLOYEES, DESKS, EQUIPMENT, ETC.; AND DUE TO THE HOURS OF THE DAY IN WHICH AN AREA MAY BE AVAILABLE WHEN SUBMITTING HIS BID.

2. MAINTAIN A MARK-UP SET OF DRAWINGS WHICH INDICATE VARIATIONS IN THE ACTUAL INSTALLATION FROM THE ORIGINAL DESIGN. SURRENDER DRAWINGS TO OWNER UPON COMPLETION.

3. ALL CAPACITIES ARE SCHEDULED AT JOBSITE ALTITUDE OF 0 FT. ABOVE SEA LEVEL.

4. COORDINATE ALL PENETRATIONS OF THE FLOOR SLAB PRIOR TO COMMENCING WORK UTILIZE X-RAY AND VISUAL INVESTIGATION OF EXISTING CONDITIONS AS REQUIRED PRIOR TO DRILLING OR CUTTING. COORDINATE ALL NEW PENETRATIONS WITH OTHER DIVISIONS OF THE WORK. ALL CONTRACTORS ARE INDIVIDUALLY RESPONSIBLE FOR ALL PENETRATIONS REQUIRED BY THEIR DIVISIONS.

ELECTRICAL COORDINATION:

1. VERIFY THE ELECTRICAL SERVICE PROVIDED BY THE ELECTRICAL CONTRACTOR BEFORE ORDERING ANY MECHANICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS.

2. PROVIDE PREMIUM EFFICIENCY MOTORS WITH 1.15 SERVICE FACTOR ON ALL EQUIPMENT, MOTORS SHALL BE CAPABLE OF OPERATING CONTINUOUSLY AT 105°F UNDER JOBSITE CONDITIONS AND ALTITUDE.

3. UNLESS NOTED OTHERWISE, ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH HOA SWITCH AND STARTER COMPATIBLE WITH EQUIPMENT AND BMS SYSTEM. STARTERS SHALL BE PROVIDED BY DIVISION 21,22 AND 23 UNLESS IN A MOTOR CONTROL CENTER. ALL DISCONNECTS SHALL BE FURNISHED BY DIVISION 26.

4. THE ELECTRICAL POWER FOR CERTAIN EQUIPMENT PROVIDED UNDER DIVISION 21,22 AND 23 HAS NOT BEEN SPECIFICALLY INDICATED ON THE ELECTRICAL DRAWINGS AND MUST BE PROVIDED BY AND FIELD COORDINATED BY THE DIVISION 21,22 AND 23 TRADE REQUIRING SUCH POWER.

SUFFICIENT POWER FOR THIS PURPOSE SHALL BE FURNISHED AS "SPARE", DEDICATED CIRCUIT CAPACITY IN DIVISION 26'S PANELBOARDS. ALL WIRING, CONDUIT AND ELECTRICAL DEVICES DOWNSTREAM OF THE PANELBOARDS IS THE RESPONSIBILITY OF THE DIVISION 21,22 AND 23 TRADE REQUIRING THE POWER UNLESS OTHERWISE SHOWN ON THE ELECTRICAL DRAWINGS.

SUCH EQUIPMENT IS HEREBY DEFINED AS:

A. ELECTRICAL HEAT TRACE. REQUIRED HEAT TRACE LOCATIONS, CAPACITIES AND SPECIFICATION ARE SHOWN OR INDICATED ON THE DRAWINGS. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

B. FIRE PROTECTION AIR COMPRESSORS, DRY-PIPE CONTROL PANELS AND VALVES. REQUIRED CONNECTIONS ARE INCLUDED IN THE DIVISION 21 WORK, AND WILL BE SHOWN BY THAT CONTRACTOR'S ENGINEERED SYSTEM DESIGN DRAWINGS.

(1) PRE-ACTION SYSTEM INITIATION SIGNALS (SUCH AS SMOKE DETECTORS, OR GENERAL ALARM CONDITIONS IN A PRE-ACTION ZONE) SHALL BE PROVIDED UNDER DIVISION 28 FIRE-ALARM WORK.

(2) DIVISION 21 SHALL PROVIDE PRE-ACTION CONTROL PANEL AND INTERCONNECTION BETWEEN NEAREST SUITABLE FIRE ALARM PANEL AND LOCATION OF PRE-ACTION VALVE(S).

(3) DIVISION 28 SHALL PROVIDE INTERCONNECTION BETWEEN FIRE COMMAND CENTER ALARM PANEL (PROVIDED UNDER DIVISION 28) AND REMOTE COMMUNICATION FIRE ALARM PANEL (PROVIDED UNDER DIVISION 28).

C. TEMPERATURE CONTROL PANELS, CONTROL AIR COMPRESSORS AND LINE VOLTAGE POWER FOR 24V CONTROL TRANSFORMERS. REQUIRED CONNECTION ARE INCLUDED IN DIVISION 230900 AND WILL BE SHOWN BY THAT CONTRACTOR'S CONTROL SUBMITTAL DRAWINGS.

D. IT IS NOT PERMISSIBLE TO UTILIZE "SPARE" POWER FROM ADJACENT POWER CIRCUITS TO SERVE ANY OF THE ABOVE LOADS. ALL POWER MUST COME FROM DEDICATED CIRCUITS.

5. SMOKE DETECTORS:

FOR AIR HANDLING UNITS AND AIR SYSTEMS WITH A CAPACITY EXCEEDING 2000 CFM, PROVIDE UL LISTED SMOKE DETECTORS IN RETURN AIR SYSTEMS IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE AND ELSEWHERE AS SHOWN ON THE DRAWINGS.

SMOKE DETECTORS WILL BE FURNISHED AND SET IN PLACE UNDER THIS DIVISION. DETECTORS WILL BE WIRED UNDER DIVISION 28. SMOKE DETECTORS MUST BE OF THE SAME MANUFACTURER, AND COMPATIBLE WITH THE FIRE FLARM SYSTEM PROVIDED UNDER DIVISION 28 (IF APPLICABLE).

CONNECT RELAY(S) TO FAN CONTROL CIRCUIT TO STOP FAN WHEN SMOKE IS DETECTED.

INSTALLATION:

1. SUSPEND EACH TRADE'S WORK SEPARATELY FROM THE STRUCTURE. DUCTWORK SHALL BE HELD TIGHT TO STRUCTURE EXCEPT WHERE OTHERWISE SHOWN.

2. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.

3. PROVIDE MANUFACTURER'S RECOMMENDED SERVICE CLEARANCE AROUND ALL EQUIPMENT REQUIRING SAME.

4. PROVIDE FOR SAFE CONDUCT OF THE WORK, CAREFUL REMOVAL AND DISPOSITION OF MATERIALS AND PROTECTION OF PROPERTY WHICH IS TO REMAIN UNDISTURBED.

5. PROVIDE ACCESS DOORS FOR ALL EQUIPMENT, VALVES, CLEANOUTS, ACTUATORS AND CONTROLS WHICH REQUIRE ACCESS FOR ADJUSTMENT OR SERVICING AND WHICH ARE LOCATED IN OTHERWISE INACCESSIBLE LOCATIONS.

A. FOR EQUIPMENT LOCATED IN "ACCESSIBLE LOCATIONS" SUCH AS LAY-IN CEILINGS: LOCATE EQUIPMENT TO PROVIDE ADEQUATE SERVICE CLEARANCE FOR NORMAL MAINTENANCE WITHOUT REMOVING ARCHITECTURAL, ELECTRICAL OR STRUCTURAL ELEMENTS SUCH AS THE CEILING SUPPORT SYSTEM, ELECTRICAL FIXTURES, ETC. "NORMAL MAINTENANCE" INCLUDES, BUT IS NOT LIMITED TO:FILTER CHANGING; GREASING OF BEARINGS; USING P/T PORTS FOR PRESSURE OR TEMPERATURE MEASUREMENTS; SERVICING CONTROL VALVES AND SERVICING CONTROL PANELS.

6. ISOLATE ALL PRESSURIZED PIPE (WATER, ETC.) AT EACH RISER, BRANCH, PIECE OF EQUIPMENT, AND AREA SERVED.

7. PROVIDE PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS SHOWN ON DRAWINGS. PRIMERS MAY BE CONNECTED TO FLUSH FIXTURES OR BE STAND ALONE. SEE SPECIFICATIONS.

8. NO DOMESTIC WATER, CHILLED WATER, OR HEATING WATER LINES SHALL BE LOCATED EXPOSED IN FINISHED SPACES OR BELOW THE BUILDING SLAB UNLESS SHOWN OTHERWISE ON THE DRAWINGS.

9. NO GAS LINES SHALL BE LOCATED BELOW BUILDING SLAB.

10. ALL CURBS, ROOF JACKS, ROOF THIMBLES, SANITARY VENTS, ROOF DRAINS, ETC. SHALL BE COMPATIBLE WITH ROOFING SYSTEM TO BE PROVIDED. REFERENCE ARCHITECTURAL DIVISION FOR REQUIRED FLASHING DETAILS.

11. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL CONCRETE EQUIPMENT PAD DIMENSIONS, BASED ON THE FINAL EQUIPMENT SELECTION, TO THE STRUCTURAL AND GENERAL CONTRACTOR FOR INCLUSION IN THOSE CONTRACTOR'S WORK AS DESCRIBED BY THE GENERAL CONTRACTOR.

12. WARRANTY: AT A MINIMUM, THE ENTIRE MECHANICAL SYSTEM SHALL BE WARRANTED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR AFTER ACCEPTANCE OF THE SYSTEM BY THE OWNER. REFER TO INDIVIDUAL SPECIFICATION SECTIONS FOR SPECIFIC WARRANTY REQUIREMENTS.

DUCTWORK INSTALLATION:

1. SEAL ALL SEAMS (LONGITUDINAL AND TRANSVERSE) AIR TIGHT WITH SEALANT PER SPECIFICATIONS.

2. DUCT DIMENSIONS ARE INSIDE CLEAR.

3. DIFFUSER NECK SIZE IS SAME AS FLEXIBLE DUCT SIZE.

4. UNLESS OTHERWISE NOTED, ALL CHANGES IN DIRECTION SHALL BE MADE WITH RADIUS ELBOWS WITH RADIUS TO CENTERLINE EQUAL TO 1.5 DUCT WIDTH.

5. WHERE REQUIRED FOR SPACE CONSTRAINTS, PROVIDE MITERED ELBOWS WITH TURNING VANES AS FOLLOWS:

A. FOR DUCT WIDTHS OF 36" OR LESS, PROVIDE MANUFACTURED SINGLE WIDTH TURNING VANES, WITH NO TRAILING EDGES AND SPACING IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS FOR "STANDARD SPACING".

B. USE DOUBLE THICKNESS (AIRFOIL) BLADES WITHOUT TRAILING EDGES FOR DUCT WIDTHS GREATER THAN 36".

6. ALL FLEXIBLE DUCTS SHALL NOT BE LESS THAN 4', OR MORE THAN 10' IN LENGTH. INSTALL FLEXIBLE DUCTWORK SUCH THAT:

A. MINIMUM OVERALL LENGTH OF 3D, STRAIGHT INTO NECK OF DIFFUSER.

B. MAXIMUM OF 135° OF TOTAL TURNING IN ENTIRE LENGTH OF FLEXIBLE DUCT.

C. MINIMUM TURNING RADIUM OF R = 1.5D.

D. WHERE: * D = FLEXIBLE DUCT DIAMETER * R = RADIUS OF TURN AS MEASURED TO CENTERLINE OF DUCT.

7. RETURN AIR PLENUM: THE HVAC SYSTEM WILL USE THE SPACE ABOVE THE CEILING AS A RETURN AIR PLENUM. CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF NFPA AND LOCAL CODE REQUIREMENTS FOR ALL MATERIAL INSTALLED IN THE RETURN AIR PLENUM.

A. IN ADDITION, THE CONTRACTOR SHALL PROVIDE A COMPLETE RETURN AIR PATH BETWEEN ALL RETURN AIR DEVICES (GRILLES ETC.) AND THEIR RESPECTIVE HVAC UNIT. MAXIMUM VELOCITY OF RETURN AIR IN PLENUM SHALL GENERALLY NOT EXCEED 250 FEET PER MINUTE, NOR EXCEED 750 FEET PER MINUTE AT ANY CROSS-SECTION OF THE RETURN AIR PATH.

8. BRANCH LINES:

A. MAKE ALL TAPS TO ROUND DUCTWORK WITH CONICAL TEES.

B. MAKE ALL TAPS TO RECTANGLE DUCTWORK WITH 45° ENTRY OR CONICAL SPIN IN TO ROUND.

C. INCLUDE DAMPERS AT ALL BRANCH LINES.

9. DUCT SIZES NOT CALLED OUT SHALL BE DETERMINED BASED ON 0.08" S.P. LOSS OR LESS PER 100 FT. OF LENGTH.

10. ASSUME ROUND OR OVAL DUCTS IN EXPOSED AREAS.

11. INCLUDE DAMPERS AT ALL BRANCH LINES, WHERE SHOWN ON THE DRAWINGS, AND WHERE OTHERWISE REQUIRED FOR BALANCING.

PIPE INSTALLATION:

1. ALL PIPING SHALL BE ADEQUATELY SUPPORTED FROM THE BUILDING STRUCTURE TO PREVENT SAGGING, POCKETING, SWAYING OR DISPLACEMENT BY MEANS OF HANGERS AND SUPPORTS. PIPING IS NOT TO BE SUPPORTED BY EQUIPMENT.

2. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR MATERIALS.

3. PROVIDE MANUAL AIR VENTS AND CAPPED HOSE-END DRAINS WITH ISOLATION VALVES AT PIPING HIGH AND LOW POINTS.

4. WELD PIPE IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS. WELDERS SHALL BE CERTIFIED FOR TYPE OF WORK BEING PERFORMED.

5. FLUSH OUT PIPING AND REMOVE CONTROL DEVICES BEFORE PERFORMING PRESSURE TEST. DO NOT USE PIPING SYSTEM VALVES TO ISOLATE SECTIONS WHERE TEST PRESSURE EXCEEDS VALVE PRESSURE RATING. PRESSURIZE PIPING AT 100 PSIG. IF LEAKAGE IS OBSERVED OR IF TEMPERATURE COMPENSATED PRESSURE DROP EXCEEDS 1% OF TEST PRESSURE, REPAIR LEAKS AND RETEST. DO NOT USE AIR PRESSURE TO TEST PLASTIC PIPE.

CONDENSATE DRAINAGE:

1. PROVIDE CONDENSATE DRAINAGE FOR ALL COOLING COILS AND OVERFLOW PANS.

2. ROUTE CONDENSATE PIPING, FULL SIZE OF DRIP PAN CONNECTION, TO NEAREST CODE APPROVED RECEPTACLE. INSULATE WHERE LOCATED ABOVE FINISHED CEILINGS.

3. HEAT TRACE CONDENSATE LINES FROM FOOD SERVICE EQUIPMENT.

LOUVERS:

1. ALL LOUVERS LOCATED ON EXTERIOR WALLS SHALL BE PROVIDED BY ARCHITECTURAL DIVISION. ALL OTHER LOUVERS SHALL BE PROVIDED BY DIVISION 23. REQUIRED LOUVER FREE AREAS ARE INDICATED ON DIVISION 23 AND 23 DRAWINGS. IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO CONFIRM THAT THE REQUIRED FREE AREA HAS BEEN PROVIDED, PRIOR TO CONNECTION TO THAT LOUVER. DIVISION 23 SHALL PROVIDE ALL LOUVER PLENUMS.

CUTTING, PATCHING AND DEMOLITION:

1. KEEP DEMOLITION & CUTTING TO MINIMUM REQUIRED FOR PROPER EXECUTION OF WORK.

2. BE RESPONSIBLE FOR ALL CUTTING AND PATCHING NECESSARY FOR THE COMPLETION OF THE WORK.

3. NO CUTTING (NOT SHOWN ON THE CONTRACT DOCUMENTS) SHALL BE DONE WITHOUT THE APPROVAL OF THE ARCHITECT AS TO LOCATIONS, METHOD AND EXTENT OF THE CUTTING.

4. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH EXISTING CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY, APPEARANCE OR FUNCTION.

5. ALL "CAPPED" SANITARY AND VENT LINES SHALL BE RECONNECTED OR RE- ROUTED AS NECESSARY TO PREVENT "DEAD-ENDS" IN THE PIPING. ALL PIPING SHALL DRAIN TO ACTIVE SANITARY WASTE LINES AND ALL BRANCHES WITH TRAPS SHALL BE ADEQUATELY VENTED.

GENERAL PLUMBING CONTRACT REQUIREMENTS:

1. THE GENERAL MECHANICAL REQUIREMENTS PERTAIN TO THE WORK OF THIS DIVISION.

2. PREPARE SHOP DRAWINGS OF ALL NEW WORK (INCLUDING SLEEVE LOCATIONS) TO VERIFY LOCATIONS AND COORDINATION OF WORK BETWEEN TRADES PRIOR TO INSTALLATION.

3. ALL DRAIN GRATES, CLEANOUT COVERS, AND OTHER FINISHED, EXPOSED COMPONENTS SHALL BE PROTECTED FROM DAMAGE. DAMAGED COMPONENTS SHALL BE REPLACED BY CONTRACTOR AT NO ADDITIONAL COST TO THE CONTRACT.

4. COORDINATE ROUTING OF ALL PLUMBING PIPING BELOW SLAB WITH STRUCTURAL GRADE BEAMS, TIE BEAMS, ETC. ALLOW FOR REROUTING OF PIPING AS REQUIRED.

5. ALL REQUIRED OPENINGS IN CONCRETE BEAMS AND STRUCTURAL WALLS ARE TO BE ACCOMPLISHED USING SLEEVES PROPERLY SIZED FOR THE PIPE THEY SERVE. CORE DRILLING IN BEAMS IS NOT ALLOWED. CORE DRILLING IN PANS IS ALLOWED UPON PRIOR APPROVAL OF ARCHITECT AND STRUCTURAL ENGINEER.

6. HORIZONTAL STORM AND SANITARY PIPING SHALL RUN AT A SLOPE OF 1/4" PER FOOT MINIMUM FOR 3" AND SMALLER PIPING. 4" AND LARGER PIPING SHALL RUN AT 1/8" PER FOOT MINIMUM.

7. NO DOMESTIC WATER LINES SHALL BE LOCATED EXPOSED IN FINISHED SPACES OR BELOW THE BUILDING SLAB UNLESS SHOWN OTHERWISE ON THE DRAWINGS.

8. WHERE SHOWN, MINIMIZE THE NUMBER OF JOINTS ON ANY PRESSURIZED PIPING BELOW CONCRETE SLABS. ALL BELOW GRADE PIPING TO BE PRESSURE TESTED AND WITNESSED BY ARCHITECT BEFORE BACKFILLING.

9. ALL CLEANOUTS FOR HORIZONTAL STORM DRAINAGE SYSTEM SHALL BE PIPE SIZE OR MAXIMUM 6" FOR LARGER PIPE.

10. IN ADDITION TO THE CLEANOUT LOCATIONS SHOWN ON DRAWINGS, PROVIDE ADDITIONAL CLEANOUTS AT:

A. ALL UPPER TERMINALS.

B. EACH RUN OF PIPING WHICH IS MORE THAN 100 FEET IN LENGTH OR FRACTION THEREOF.

C. HORIZONTAL LINES 5 FEET OR MORE.

D. HORIZONTAL LINES FOR EACH AGGREGATE CHANGE OF DIRECTION EXCEEDING 135 DEGREES.

E. AT THE BASE OF ALL WASTE AND VENT RISERS. ALL VERTICAL CLEANOUTS SHALL BE SIZED TO ACCOMMODATE THE LARGEST PIPE ON THAT BRANCH LINE, BUT NEVER LARGER THAN 4".

11. NO GAS LINES SHALL BE LOCATED BELOW BUILDING SLAB. ALL GAS PIPING IN AIR PLENUMS TO BE WELDED.

12. PROVIDE ISOLATION VALVES ON ALL PIPING SERVING HOSE BIBBS.

13. ANY ELECTRICAL SPACE NOT CONSTRUCTED WITH A SUB-ROOF WHICH MAY HAVE PLUMBING PIPING AT THE CEILING OF THESE SPACES SHALL HAVE A DRIP PAN INSTALLED BELOW THE PIPING. DRIP PANS SHALL BE 1.5 TIMES THE WIDTH OF THE PIPING SERVED WITH A MINIMUM OF 2" HIGH SIDES. DRIP PANS SHALL BE SUSPENDED FROM THE PIPING SERVED AND SHALL SLOPE AT A MINIMUM 1/8"/FT. DRIP PANS SHALL DISCHARGE WITH MIN. 1-1/2" DR TO FLOOR DRAINS.

A. DO NOT LOCATE PIPING DIRECTLY ABOVE ANY ELECTRICAL EQUIPMENT IN ELECTRICAL ROOMS.

14. MAINTAIN DESIGNATED PLUMBING FIXTURE HEADER SIZE FOR FULL BANK OF FIXTURES.

15. PROVIDE GAS VENTS EXTENDING CONTINUOUSLY FROM ALL INTERIOR GAS REGULATORS TO THE EXTERIOR OF THE BUILDING. TERMINATE AT AN APPROVED LOCATION. SIZE VENTS SUCH THAT MINIMUM VENT SIZE (FOR VENT WHICH IS 10 FEET OR LESS IN LENGTH) EQUALS RELIEF OUTLET PIPE SIZE. INCREASE VENT PIPE SIZE ONE PIPE SIZE FOR EVERY ADDITIONAL TEN FEET OF VENT PIPE LENGTH.

A. PROVIDE AN ISOLATION VALVE DOWNSTREAM OF EVERY INTERIOR GAS REGULATOR.

STRUCTURE: 1. DO NOT PENETRATE STRUCTURAL MEMBERS. ALL EQUIPMENT SUPPORTS SHALL BE ATTACHED TO THE LOAD BEARING MEMBERS OF STRUCTURAL ELEMENTS. DO NOT OVER-STRESS ANY STRUCTURAL MEMBERS. CONTACT STRUCTURAL ENGINEER FOR ALLOWABLE LOADS FOR SPECIFIC MEMBERS.

2. DO NOT UTILIZE POWER DRIVEN ANCHORS FOR ANY LOCATIONS WHICH REQUIRE THE LOAD TO BE HELD IN TENSION. SEE STRUCTURAL DIVISION FOR ADDITIONAL RESTRICTIONS.

3. SEE ALSO STRUCTURAL DIVISION FOR ACCEPTABLE ANCHORING AND SUPPORT MEANS, METHODS, AND LOCATIONS.

4. PROVIDE FLEXIBLE CONNECTORS, EXPANSION LOOPS, EXPANSION JOINTS, ADDITIONAL FITTINGS OR EQUIVALENT TO ACCOMMODATE THE THERMAL EXPANSION OF THE BUILDING THROUGH STRUCTURAL EXPANSION JOINTS. PROVIDE SUCH FITTING AT EVERY PIPE, DUCT, CONDUIT, ETC. CROSSING OF A STRUCTURAL EXPANSION JOINT.

CONSTRUCTION VENTILATION:

1. WHERE EXISTING OR NEW MECHANICAL SYSTEMS ARE USED FOR TEMPORARY VENTILATION OR CLIMATE CONTROL, MECHANICAL EQUIPMENT INSTALLER SHALL PROVIDE CONSTRUCTION FILTERS, MAINTAIN EQUIPMENT, AND CLEAN, ADJUST AND PUT IN NEW CONDITION BEFORE BUILDING OCCUPANCY. PARTS AND LABOR WARRANTY SHALL NOT BE CONSIDERED TO START UNTIL ACCEPTANCE OF SYSTEM BY OWNER.

2. PROVIDE CONSTRUCTION FILTERS INSTALLED AT ALL AIR MOVING DEVICES THROUGHOUT THE CONSTRUCTION. REMOVE FILTERS ONLY FOR BALANCING AND FINAL TURNOVER. INSPECT ALL NON-CONSTRUCTION FILTERS AND REPLACE ALL THOSE DEEMED NECESSARY BY THE ENGINEER PRIOR TO ACCEPTANCE OF THE SYSTEM BY THE OWNER.

GAS FIRED VENTING REQUIREMENTS:

1. ALL FLUES SERVING GAS FIRED EQUIPMENT SHALL BE DOUBLE WALL TYPE "B" BY METALBESTOS CO. OR EQUAL. TERMINATE FLUES A MINIMUM HEIGHT ABOVE ROOF (AS DETERMINED BY CODE) WITH WEATHER CAP. SLOPE HORIZONTAL RUNS TOWARD POINT OF ORIGINATION AT MINIMUM 1/4" PER 1'.

FIRE PROTECTION NOTES:

1. FIRE PROTECTION NOTES

A. SUBMIT SHOP DRAWINGS SHOWING PROPOSED LAYOUT OF FIRE PROTECTION SYSTEM. DRAWINGS SHALL SHOW ACTUAL EQUIPMENT TO BE USED, DIMENSIONS AND HYDRAULIC CALCULATIONS. SHOP DRAWINGS SHALL BE APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION PRIOR TO SUBMITTAL TO ENGINEER OR ARCHITECT.

B. SHOW THE CONNECTING MAIN AND BRANCH PIPE SIZES FOR ALL RELOCATED EXISTING SPRINKLER HEADS.

C. CONFORM TO HAZARD OCCUPANCY REQUIREMENTS OF NFPA 13.

2. THE ENTIRE BUILDING SHALL BE SERVED BY A WET PIPE TYPE FIRE SPRINKLER SYSTEM. COORDINATE ELECTRICAL, FIRE PROTECTION AND MECHANICAL SPACE REQUIREMENTS CAREFULLY BEFORE PROCEEDING WITH INSTALLATION.

3. EXTEND THE EXISTING SPRINKLER SYSTEM, RELOCATE EXISTING AND ADD NEW SPRINKLER HEADS IN ACCORDANCE WITH NFPA 13, ALL APPLICABLE CODES AND ORDINANCES AND PROJECT REQUIREMENTS TO COMPLETELY PROTECT THE NEW WORK.

4. SYSTEM SHALL BE INSTALLED COMPLETE AND OPERATIONAL, INCLUDING WATER FLOW INDICATOR, CONNECTIONS TO EXISTING ALARM, DRAIN PIPING, IDENTIFICATION SIGNS, ETC.

5. WORK SHALL BE PERFORMED BY A QUALIFIED FIRE SPRINKLER INSTALLER WITH A MINIMUM OF (5) FIVE YEARS EXPERIENCE IN SIMILAR INSTALLATIONS.

6. COORDINATE ALL WORK WITH ALL OTHER TRADES.

7. SUPPLY OWNER AN EXTRA STOCK OF SIX SPRINKLER HEADS (6), THREE (3) OF EACH TYPE, AND A SPRINKLER WRENCH.

FIRE STOPPING:

1. FIRE STOPPING REQUIREMENT: PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM-E-814. ACCEPTANCE MATERIALS NCLUDE: DOW CORNING RTV FIRE STOP FOAM FOR BARE PIPE, METAL CONDUIT, AND ELECTRICAL CABLE; 3M FIRE DAM 21,22 AND 230 CAULK FOR BARE PIPE, METAL CONDUIT, AND BUILDING CONSTRUCTION; GAPS 3M FS-195 INTUMESCENT STRIPS FOR INSULATED PIPES, PLASTIC PIPE OR CONDUIT, AND ELECTRICAL CABLE.

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 9

:53

:38

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M0.01

MECHANICAL GENERALNOTES

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 6: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

RE

F.

REF.

UPUPUP

F/S

NEWPARKINGGARAGE

NEWCOMMONSBUILDING

CENTRAL

PLANT

L100

SITE PLAN IS DIAGRAMATIC IN NATURE. MECHANICAL CONTRACTOR TO FIELD VERIFY EXACT ROUTING AND SIZE OF EXISTING CHILLED WATER PIPING. COORDINATE POSSIBLE RELOCATION WITH OWNER'S REQUIREMENTS.

(E) CHS/R

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:43

:59

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M1.00

MECHANICAL SITE PLAN

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1" = 40'-0" 1MECHANICAL SITE PLAN

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 7: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

EL.13' - 2"

LEVEL 2

EL.13' - 2"

LEVEL 2

EL.14' - 0"

LEVEL 2 - MECHANICAL

MEZZANINE

12"øSA

12"øSA

18"x18"SA

C-3

VAV

C-4

VAV

26"x10"SA

26"x10"SA

EL.28' - 0"

LEVEL 3

EL.42' - 0"

LEVEL 4

EL.28' - 0"

LEVEL 3

EL.41' - 6"

LEVEL 4

34"øSA

ROUTE DUCT BETWEEN STRUCTURAL MEMBERS AS SHOWN. REFER TO DETAIL 6 SHEET M7.00 FOR DETAILS. TYPICAL OF ALL ROUND DUCT IN GYMNASIUM.

EL.13' - 2"

LEVEL 2

EL.28' - 0"

LEVEL 3

EL.13' - 2"

LEVEL 2

EL.28' - 0"

LEVEL 3

EL.14' - 0"

LEVEL 2 - MECHANICAL

MEZZANINE

EL.28' - 0"

LEVEL 3

22"x44"SA

40"x

36"R

A

40"x36"SA

C-2

AHU

C-1

EDH

40"x36" RELIEF AIR

34"x44" OA

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:43

:59

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M2.00

MECHANICAL SECTIONVIEWS

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

JAN 09, 2019 PERMIT & BID

1/4" = 1'-0"1

VAV C-3 AND C-4

1/4" = 1'-0"2

FABRIC DUCT THROUGH STRUCTURE

1/4" = 1'-0"3

AHU C-1

01-09-2019

Page 8: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

UP

UPUP

SH

SH

SH

SH

SH

SH

M

M

CA CB CC CD

C1

C2

C3

C4

C4.2

C5

C5.2

CA.3 CC.5

C4.6

LOBBY

C100

STUDIO

C112

MEN

C106

WOMEN

C107

GYMNASIUM

C113

STAGE

C116

GREEN RM

C115

OUTSIDE

STOR.

C117

LOCKER

C121CONF

C120

OFFICE

C122

UCAL STOR

C103

ATHLETIC

STOR

C104

TICKET &

VENDING

C101

P.E. INDOOR

STOR

C105

ADVANCEMENT

STOR

C102

TABLE &

CHAIR STOR.

C114

FAMILY

C109

JAN

C108

GIRLS

LOCKER

C119

BOYS LOCKER

C118

LOGGIA

C124

CHEER

C110ELEC

C111 EAST

CORRIDOR

C123

8"x8"EA

12"x12"EA

200A

8"ø 250A

10"ø

C-1

CU

12"x

12"S

A

32"x26"SA

16"x12"SA12"x10"SA

16"x12"SA

20"x12"SA

16"x12"SA

12"x12"SA

50A

6"ø

200A

8"ø

200A

8"ø C-2

VAV

C-1

VAV

C-5

VAV

C-6

VAV

C-7

VAV

200A

8"ø

50A

6"ø

325A (2)

12"ø

200A (3)

10"ø

150A

8"ø

T

T

T

TT

T

10"x12"EA

12"x12"EA

16"x16"EA

M15

M15

14"x12"EA

M15

M15

M15

M15

(14 SF FREE AREA)

(4 SF FREE AREA)

M11(4 SF FREE AREA)

M12

-42"x18"

E

18"øSA

26"x4"D (6)

200

26"x4"D

200

C-1

AHU

20"øSA20"x14"OA

20"x14"RA

20"x

20"R

A

FIRE RISER

C124

C-1

UH

T

M15 C-8

VAV

T M15

12"øSA

C-1

REF

T

-12"x6"

E

CB CC CD

CD

M20

-18"x10"

E (4)

6"x6"F

100

10"x6"D(4)

200

12"x6"RA

22"x12"RA

-18"x10"

E (4)

(TYP. 3)

-36"x24"

E

-22"x22"

C (2)

C-1

TF12"x12"

D140-

12"x12"F

50"x24"RA

40"x24"RA

12"x24"RA

VAV-4

18"x18"SA

20"x12"SA20"x12"SA

12"x12"SA12"x12"SA

400G (8)

10"ø

T

280G (10)

10"ø

400G (8)

10"ø

VAV-3

40"x24"RA

24"x24"RA

M17

SD

20"x

12"S

A

20"x

12"S

A

14"x12"SA

28"x16"SA

24"x16"SA

M1

M7

1

M2.00

M22M22

M291"DR

48"x

16"S

A

48"x18"SA

36"x30"SA

44"x24"RA

M4

M1

M15

-12"x12"

E(2)

-18"x10"

E

28"x

16"S

A

6"ø

100B

SP

CO2

12"ø

375B

12"ø

375B

6"x6"D

50

6"ø

100B

12"x12"D

150

48"x30"RA

200A (3)

10"ø 10"ø

250B (3)

10"ø

250B (3)

-22"x22"

C

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:54

:13

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

1-M2.01

MECHANICAL LEVEL 1FLOOR PLAN

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1/8" = 1'-0" 1MECHANICAL LEVEL 1 FLOOR PLAN - COMMONS

1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR IS RESPONSIBLE FOR ALL OFFSETS, TRANSITIONS, ELBOWS, ETC. AS REQUIRED IN DUCTWORK, PIPING, SUPPORTS, ETC. TO COMPLETE THE WORK IN A CLEAN FUNCTIONAL INSTALLATION THAT IS FULLY COORDINATED WITH ALL OTHER TRADES. ANY PRICING EFFORT SHALL TAKE THESE FACTORS INTO ACCOUNT.

2. MAINTAIN CODE REQUIRED AREA OF SEPARATION FROM OUTSIDE AIR INTAKES TO TERMINATIONS OF EXHAUST, COMBUSTION AIR, PLUMBING VENTS, ETC.

3. COORDINATE EQUIPMENT HOUSEKEEPING PAD DIMENSIONS AND LAYOUT WITH THE GENERAL CONTRACTOR BASED ON FINAL EQUIPMENT SIZES.

4. PROVIDE MANUAL BALANCE DAMPERS IN ALL SUPPLY DUCT BRANCH TAPS DOWNSTREAM OF VAV BOXES.

5. PROVIDE MANUAL BALANCE DAMPERS IN ALL EXHAUST DUCT BRANCH TAPS.

6. PROVIDE TRANSFER "Z" BOOT DUCTS IN FULL HEIGHT WALLS WHERE A PLENUM RETURN SYSTEM IS UTILIZED. BOOTS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 400 FPM. PROVIDE A GRILLE FOR ALL TRANSFERS IN EXPOSED AREAS. RE: ARCH. OPENINGS OF "Z" BOOT DUCTS SHALL BE AT LEAST 12" CLEAR OF STRUCTURE.

7. COORDINATE SPACE TEMPERATURE SENSORS AND THERMOSTAT LOCATIONS TO ALIGN VERTICALLY WITH LIGHT SWITCHES.

8. TEMPERATURE CONTROLS CONTRACTOR SHALL SUBMIT PLANS INDICATING ALL SPACE TEMPERATURE SENSORS, T-STATS, HUMIDITY SENSORS, ETC. AS PART OF SUBMITTAL PROCESS FOR A/E REVIEW PRIOR TO ROUGH-IN.

9. PROVIDE THROUGH FACE BALANCING FOR ALL DIFFUSERS, REGISTERS, AND GRILLES ABOVE INACCESSIBLE AREAS.

10. PROVIDE TURNING VANES IN ALL 90° DUCT ELBOWS.

11. INSTALL EXPOSED DUCTWORK AS HIGH AS POSSIBLE.

13. ALL DUCT/PIPE PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS SHALL BE CAULKED AND SEALED TO MEET THE RATING REQUIRED. REFER TO LIFE SAFETY DRAWINGS FOR FIRE/SMOKE RATING REQUIREMENTS.

14. PROVIDE ISOLATION VALVES AT EACH BRANCH LINE OFF OF RISER.

15. PROVIDE 3/4" BRANCH PIPING TO ALL TERMINAL UNITS, UNLESS NOTED OTHERWISE.

16. PROVIDE CONDENSATE DRAIN FROM ALL CHILLED WATER COILS AND DX EVAPORATOR COILS TO LAVATORY TAIL PIECE OR MECHANICAL ROOM FLOOR DRAIN. PROVIDE CONDENSATE PUMP FOR WALL MOUNTED UNITS AND CONCEALED UNITS THAT CANNOT BE GRAVITY DRAINED TO TERMINATION LOCATION

GENERAL NOTES:

KEYNOTES

M1 SA DUCT UP.

M4 RA DUCT UP.

M7 EA DUCT UP.

M11 RELIEF AIR LOUVER WITH 18" PLENUM.

M12 REFRIGERANT PIPING TO/FROMFCU/CU. SIZE PER MANUFACTURER'SRECOMMENDATIONS.

M15 T-STAT LOCATED ON WALL BY DIV 23CONTRACTOR. FINAL LOCATION OFT-STAT SHALL BE COORDINATED WITHARCHITECT PRIOR TO INSTALLATION.

M17 ROUTE CONDENSATE FROMAC/AHU/RTU TO TAILPIECE OFLAVATORY AS ALLOWED BY AHJ.

M20 ROUND DOUBLE WALL SPIRAL DUCT INAREAS WITH EXPOSDED DUCTWORK.USE OF FLEX DUCT NOT PERMITED INAREAS WITH EXPOSED DUCTWORK.EXPOSED DUCTWORK SHALL BEPAINTED AND WRAPPED PERARCHITECT'S INSTRUCTIONS.

M22 REFER TO MEZZANINE PLAN FORCONTINUATION.

M29 MECHANICAL CONDENSATE PIPING UP.

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 9: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

MECHANICAL

PLATFORM

C127

34" FABRIC DUCT 34" FABRIC DUCT

C-2.2

CU

C-2.1

CU

C-1

EF

-96"x36"

E

(16 SF FREE AREA)

(16 SF FREE AREA)

M13M13

M16

IDF

C128

C-3

AC

C-3

CU

M12

C-1

EDH

34"x44"OA

44"x22"SA

40"x36"SA

40"x36"RA

REFRREFR

2

M2.00

C-3

VAV

C-4

VAV

C-2

EFM16

1"D

R

3/4"DR

M30

M18M18

TCO2SD

18"x18"SAM2

1

M2.00

M23 M23

M25M26

M26

M27

M28 M28

C-2

AHU

3

M2.00

40"x36" RELIEF AIR

M35

C-1

RTU

M5M24

M2M24

T SPM10

M11

M37

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:43

:50

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

1-M2.02

MECHANICAL LEVEL 2MEZZANINE/ROOF FLOORPLAN

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1/8" = 1'-0" 1MECHANICAL LEVEL 2 MEZZANINE - COMMONS

1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR IS RESPONSIBLE FOR ALL OFFSETS, TRANSITIONS, ELBOWS, ETC. AS REQUIRED IN DUCTWORK, PIPING, SUPPORTS, ETC. TO COMPLETE THE WORK IN A CLEAN FUNCTIONAL INSTALLATION THAT IS FULLY COORDINATED WITH ALL OTHER TRADES. ANY PRICING EFFORT SHALL TAKE THESE FACTORS INTO ACCOUNT.

2. MAINTAIN CODE REQUIRED AREA OF SEPARATION FROM OUTSIDE AIR INTAKES TO TERMINATIONS OF EXHAUST, COMBUSTION AIR, PLUMBING VENTS, ETC.

3. COORDINATE EQUIPMENT HOUSEKEEPING PAD DIMENSIONS AND LAYOUT WITH THE GENERAL CONTRACTOR BASED ON FINAL EQUIPMENT SIZES.

4. PROVIDE MANUAL BALANCE DAMPERS IN ALL SUPPLY DUCT BRANCH TAPS DOWNSTREAM OF VAV BOXES.

5. PROVIDE MANUAL BALANCE DAMPERS IN ALL EXHAUST DUCT BRANCH TAPS.

6. PROVIDE TRANSFER "Z" BOOT DUCTS IN FULL HEIGHT WALLS WHERE A PLENUM RETURN SYSTEM IS UTILIZED. BOOTS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 400 FPM. PROVIDE A GRILLE FOR ALL TRANSFERS IN EXPOSED AREAS. RE: ARCH. OPENINGS OF "Z" BOOT DUCTS SHALL BE AT LEAST 12" CLEAR OF STRUCTURE.

7. COORDINATE SPACE TEMPERATURE SENSORS AND THERMOSTAT LOCATIONS TO ALIGN VERTICALLY WITH LIGHT SWITCHES.

8. TEMPERATURE CONTROLS CONTRACTOR SHALL SUBMIT PLANS INDICATING ALL SPACE TEMPERATURE SENSORS, T-STATS, HUMIDITY SENSORS, ETC. AS PART OF SUBMITTAL PROCESS FOR A/E REVIEW PRIOR TO ROUGH-IN.

9. PROVIDE THROUGH FACE BALANCING FOR ALL DIFFUSERS, REGISTERS, AND GRILLES ABOVE INACCESSIBLE AREAS.

10. PROVIDE TURNING VANES IN ALL 90° DUCT ELBOWS.

11. INSTALL EXPOSED DUCTWORK AS HIGH AS POSSIBLE.

13. ALL DUCT/PIPE PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS SHALL BE CAULKED AND SEALED TO MEET THE RATING REQUIRED. REFER TO LIFE SAFETY DRAWINGS FOR FIRE/SMOKE RATING REQUIREMENTS.

14. PROVIDE ISOLATION VALVES AT EACH BRANCH LINE OFF OF RISER.

15. PROVIDE 3/4" BRANCH PIPING TO ALL TERMINAL UNITS, UNLESS NOTED OTHERWISE.

16. PROVIDE CONDENSATE DRAIN FROM ALL CHILLED WATER COILS AND DX EVAPORATOR COILS TO LAVATORY TAIL PIECE OR MECHANICAL ROOM FLOOR DRAIN. PROVIDE CONDENSATE PUMP FOR WALL MOUNTED UNITS AND CONCEALED UNITS THAT CANNOT BE GRAVITY DRAINED TO TERMINATION LOCATION

GENERAL NOTES:

KEYNOTES

M2 SA DUCT DOWN.

M5 RA DUCT DOWN.

M10 OUTSIDE AIR LOUVER WITH 18"PLENUM.

M11 RELIEF AIR LOUVER WITH 18" PLENUM.

M12 REFRIGERANT PIPING TO/FROMFCU/CU. SIZE PER MANUFACTURER'SRECOMMENDATIONS.

M13 CONDENSING UNIT MOUNTED ONROOF. UNIT SHALL BE ANCHORED TOROOF PER STRUCTURAL DETAILS.

M16 UPBLAST ROOF MOUNTED EXHAUSTFAN. FAN TO BE INSTALLED PERSTRUCTURAL DETAILS. EXHAUSTSHALL BE NO LESS THAN 10' CLEAR OFALL AIR INTAKES ANDPROPERTY/BUILDING LINE.

M18 ROUTE CONDENSATE FROMAC/AHU/RTU TO DRAIN AS ALLOWED BYAHJ.

M23 REFER TO FIRST FLOOR PLAN FORCONTINUATION.

M24 TRANSITION TO RTU OPENING ASREQUIRED.

M25 PROVIDE AHU ON 4" HOUSEKEEPINGPAD. REFER TO MECHANICALSCHEDULES FOR MORE INFORMATION.

M26 VAV BOXES TO BE SUPPORTED FROMVERTICAL WALL.

M27 ROUTE REFRIGERANT PIPING HIGH TOSCTRUCTURE. PIPING SHALL NOT BEOVER ANY ELECTRICAL COMPONENTS.

M28 ROUTE FABRIC DUCT THROUGHSTRUCTURE. FABRIC AIR ORIFLOWWITH DISCHARGE POSITIONS AT 4 AND8 O'CLOCK, OR APPROVED EQUAL.PROVIDE INTERNAL SKELETON TOMAINTAIN SHAPE.

M30 MECHANICAL CONDENSATE PIPINGDOWN.

M35 STACKED REFIRGERANT PIPING.

M37 BAS CONTROL PANEL. CONFIRM FINALLOCATION WITH ARCHITECT PRIOR TOINSTALLATION.

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 10: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

UP

REF.

RE

F.

UP

F/S

F/S

1 2

A

B

C

4 5 6 7 8 9 10 11 133 12

H.M. STOR

G111

UNISEX

G112

SCOUTS

G116

MEN

G104WOMEN

G105 YOUTH

G117MULTI-PURPOSE

G118

STOR 2

G108

SERVER

G102

SECURITY

G101

LOBBY

G100

S.A.F.

G106

STAIR A

G123

STAIR B

G124

150A

8"ø

G-1

VAV

210A

8"ø

10"x10"SA 12"x12"SA 12"x10"SA 8"x10"SA

G-4

VAV

50A

6"ø

14"x14"SA

20"x14"SA

10"x14"SA

18"x14"SA

375A(8)

12"ø

G-3

VAV G-5

VAV

12"x14"SA

16"x16"SA

G-6

VAV

G-2

VAV

250A

10"ø

200A (2)

8"ø

14"x14"SA

28"x16"SA46"x16"SA

52"x

16"S

A

G-1

AC

10"ø

300B (2)

100A (2)

6"ø

400A (4)

12"ø

G-1

CU

SAF STOR

G107STOR 1

G109

WORK

G110

YOUTH STOR

G113

T T

T

T

T

T

M12

M17

3/4

"DR

M15

T M15

M15

M15

M15 M15 M15

18"x6"EA

M19

M19

(1 SF FREE AREA)

(0.5 SF FREE AREA)

100A

6"ø

CORR - N

G120

CORR - W

G119

150A

8"ø

G-1

UH

T

G-2

EF

G-1

EF

1 2

C3

3 4 5 6 7 8 9 10 11 13

C1C2C5

C5

C4

A

B

C

12

C5.2 C4.2

300G(2)

10"ø

150G

8"ø

12"x6"RA

(TYP. 10)

-12"x6"

E (8)

12"x6"D (2)

110

G-3

EF

M19 (0.5 SF FREE AREA)

M21

JAN.

G129

ELECT.

G121

GIRLS STOR

G114BOY STOR

G115

G-1

TF

-12"x12"

F

48"x12"RA

8"ø

EA

48"x12"RA

(TYP. 2)

M17

44"x20"RA

44"x20"SA

M4

M1

1"DRM29

-C (TYP.)

CO2

M3712"x6"D (3)

110

12"x6"D

11012"x6"

D110

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:43

:53

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

2-M2.01

MECHANICAL LEVEL 1FLOOR PLAN

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1 : 144 1MECHANICAL LEVEL 1 FLOOR PLAN - GARAGE

1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR IS RESPONSIBLE FOR ALL OFFSETS, TRANSITIONS, ELBOWS, ETC. AS REQUIRED IN DUCTWORK, PIPING, SUPPORTS, ETC. TO COMPLETE THE WORK IN A CLEAN FUNCTIONAL INSTALLATION THAT IS FULLY COORDINATED WITH ALL OTHER TRADES. ANY PRICING EFFORT SHALL TAKE THESE FACTORS INTO ACCOUNT.

2. MAINTAIN CODE REQUIRED AREA OF SEPARATION FROM OUTSIDE AIR INTAKES TO TERMINATIONS OF EXHAUST, COMBUSTION AIR, PLUMBING VENTS, ETC.

3. COORDINATE EQUIPMENT HOUSEKEEPING PAD DIMENSIONS AND LAYOUT WITH THE GENERAL CONTRACTOR BASED ON FINAL EQUIPMENT SIZES.

4. PROVIDE MANUAL BALANCE DAMPERS IN ALL SUPPLY DUCT BRANCH TAPS DOWNSTREAM OF VAV BOXES.

5. PROVIDE MANUAL BALANCE DAMPERS IN ALL EXHAUST DUCT BRANCH TAPS.

6. PROVIDE TRANSFER "Z" BOOT DUCTS IN FULL HEIGHT WALLS WHERE A PLENUM RETURN SYSTEM IS UTILIZED. BOOTS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 400 FPM. PROVIDE A GRILLE FOR ALL TRANSFERS IN EXPOSED AREAS. RE: ARCH. OPENINGS OF "Z" BOOT DUCTS SHALL BE AT LEAST 12" CLEAR OF STRUCTURE.

7. COORDINATE SPACE TEMPERATURE SENSORS AND THERMOSTAT LOCATIONS TO ALIGN VERTICALLY WITH LIGHT SWITCHES.

GENERAL NOTES:8. TEMPERATURE CONTROLS CONTRACTOR SHALL SUBMIT PLANS INDICATING ALL SPACE TEMPERATURE SENSORS, T-STATS, HUMIDITY SENSORS, ETC. AS PART OF SUBMITTAL PROCESS FOR A/E REVIEW PRIOR TO ROUGH-IN.

9. PROVIDE THROUGH FACE BALANCING FOR ALL DIFFUSERS, REGISTERS, AND GRILLES ABOVE INACCESSIBLE AREAS.

10. PROVIDE TURNING VANES IN ALL 90° DUCT ELBOWS.

11. INSTALL EXPOSED DUCTWORK AS HIGH AS POSSIBLE.

13. ALL DUCT/PIPE PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS SHALL BE CAULKED AND SEALED TO MEET THE RATING REQUIRED. REFER TO LIFE SAFETY DRAWINGS FOR FIRE/SMOKE RATING REQUIREMENTS.

14. PROVIDE ISOLATION VALVES AT EACH BRANCH LINE OFF OF RISER.

15. PROVIDE 3/4" BRANCH PIPING TO ALL TERMINAL UNITS, UNLESS NOTED OTHERWISE.

16. PROVIDE CONDENSATE DRAIN FROM ALL CHILLED WATER COILS AND DX EVAPORATOR COILS TO LAVATORY TAIL PIECE OR MECHANICAL ROOM FLOOR DRAIN. PROVIDE CONDENSATE PUMP FOR WALL MOUNTED UNITS AND CONCEALED UNITS THAT CANNOT BE GRAVITY DRAINED TO TERMINATION LOCATION

KEYNOTES

M1 SA DUCT UP.

M4 RA DUCT UP.

M12 REFRIGERANT PIPING TO/FROMFCU/CU. SIZE PER MANUFACTURER'SRECOMMENDATIONS.

M15 T-STAT LOCATED ON WALL BY DIV 23CONTRACTOR. FINAL LOCATION OFT-STAT SHALL BE COORDINATED WITHARCHITECT PRIOR TO INSTALLATION.

M17 ROUTE CONDENSATE FROMAC/AHU/RTU TO TAILPIECE OFLAVATORY AS ALLOWED BY AHJ.

M19 EXHAUST AIR LOUVER WITH 18"PLENUM.

M21 CONDENSING UNIT MOUNTED ONWALL. UNIT SHALL BE ANCHORED PERMECHANICAL DETAILS ANDMANUFACTURER'SRECOMMENDATIONS.

M29 MECHANICAL CONDENSATE PIPING UP.

M37 BAS CONTROL PANEL. CONFIRM FINALLOCATION WITH ARCHITECT PRIOR TOINSTALLATION.

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 11: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

1 2

A

B

C

4 5 6 7 8 9 10 11 133 121 2

C3

3 4 5 6 7 8 9 10 11 13

C1C2C5

C5

C4

A

B

C

12

C4.2

44"x20"RA

44"x20"SA

1"DR

M3

M6

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:43

:54

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

2-M2.02

MECHANICAL LEVEL 2FLOOR PLAN

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1 : 144 1MECHANICAL LEVEL 2 FLOOR PLAN - GARAGE

JAN 09, 2019 PERMIT & BID

01-09-2019

1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR IS RESPONSIBLE FOR ALL OFFSETS, TRANSITIONS, ELBOWS, ETC. AS REQUIRED IN DUCTWORK, PIPING, SUPPORTS, ETC. TO COMPLETE THE WORK IN A CLEAN FUNCTIONAL INSTALLATION THAT IS FULLY COORDINATED WITH ALL OTHER TRADES. ANY PRICING EFFORT SHALL TAKE THESE FACTORS INTO ACCOUNT.

2. MAINTAIN CODE REQUIRED AREA OF SEPARATION FROM OUTSIDE AIR INTAKES TO TERMINATIONS OF EXHAUST, COMBUSTION AIR, PLUMBING VENTS, ETC.

3. COORDINATE EQUIPMENT HOUSEKEEPING PAD DIMENSIONS AND LAYOUT WITH THE GENERAL CONTRACTOR BASED ON FINAL EQUIPMENT SIZES.

4. PROVIDE MANUAL BALANCE DAMPERS IN ALL SUPPLY DUCT BRANCH TAPS DOWNSTREAM OF VAV BOXES.

5. PROVIDE MANUAL BALANCE DAMPERS IN ALL EXHAUST DUCT BRANCH TAPS.

6. PROVIDE TRANSFER "Z" BOOT DUCTS IN FULL HEIGHT WALLS WHERE A PLENUM RETURN SYSTEM IS UTILIZED. BOOTS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 400 FPM. PROVIDE A GRILLE FOR ALL TRANSFERS IN EXPOSED AREAS. RE: ARCH. OPENINGS OF "Z" BOOT DUCTS SHALL BE AT LEAST 12" CLEAR OF STRUCTURE.

7. COORDINATE SPACE TEMPERATURE SENSORS AND THERMOSTAT LOCATIONS TO ALIGN VERTICALLY WITH LIGHT SWITCHES.

GENERAL NOTES:8. TEMPERATURE CONTROLS CONTRACTOR SHALL SUBMIT PLANS INDICATING ALL SPACE TEMPERATURE SENSORS, T-STATS, HUMIDITY SENSORS, ETC. AS PART OF SUBMITTAL PROCESS FOR A/E REVIEW PRIOR TO ROUGH-IN.

9. PROVIDE THROUGH FACE BALANCING FOR ALL DIFFUSERS, REGISTERS, AND GRILLES ABOVE INACCESSIBLE AREAS.

10. PROVIDE TURNING VANES IN ALL 90° DUCT ELBOWS.

11. INSTALL EXPOSED DUCTWORK AS HIGH AS POSSIBLE.

13. ALL DUCT/PIPE PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS SHALL BE CAULKED AND SEALED TO MEET THE RATING REQUIRED. REFER TO LIFE SAFETY DRAWINGS FOR FIRE/SMOKE RATING REQUIREMENTS.

14. PROVIDE ISOLATION VALVES AT EACH BRANCH LINE OFF OF RISER.

15. PROVIDE 3/4" BRANCH PIPING TO ALL TERMINAL UNITS, UNLESS NOTED OTHERWISE.

16. PROVIDE CONDENSATE DRAIN FROM ALL CHILLED WATER COILS AND DX EVAPORATOR COILS TO LAVATORY TAIL PIECE OR MECHANICAL ROOM FLOOR DRAIN. PROVIDE CONDENSATE PUMP FOR WALL MOUNTED UNITS AND CONCEALED UNITS THAT CANNOT BE GRAVITY DRAINED TO TERMINATION LOCATION

KEYNOTES

M3 SA DUCT UP AND DOWN.

M6 RA DUCT UP AND DOWN.

Page 12: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

DN

DN

F/S

F/S

1 2

A

B

C

4 5 6 7 8 9 10 11 133

RAMP DN

TO LVL 1

RAMP UP

TO LVL 3

12

TYP.

1 2

C3

3 4 5 6 7 8 9 10 11 13

C1C2C5

C5

C4

A

B

C

12

SD

44"x20"RA

44"x20"SA

M5

M2

1"DRM30

M31

M32

G-1

RTUM33 M34

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:43

:54

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

2-M2.03

MECHANICAL LEVEL 3FLOOR PLAN

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1 : 144 1MECHANICAL LEVEL 3 FLOOR PLAN - GARAGE

JAN 09, 2019 PERMIT & BID

01-09-2019

1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR IS RESPONSIBLE FOR ALL OFFSETS, TRANSITIONS, ELBOWS, ETC. AS REQUIRED IN DUCTWORK, PIPING, SUPPORTS, ETC. TO COMPLETE THE WORK IN A CLEAN FUNCTIONAL INSTALLATION THAT IS FULLY COORDINATED WITH ALL OTHER TRADES. ANY PRICING EFFORT SHALL TAKE THESE FACTORS INTO ACCOUNT.

2. MAINTAIN CODE REQUIRED AREA OF SEPARATION FROM OUTSIDE AIR INTAKES TO TERMINATIONS OF EXHAUST, COMBUSTION AIR, PLUMBING VENTS, ETC.

3. COORDINATE EQUIPMENT HOUSEKEEPING PAD DIMENSIONS AND LAYOUT WITH THE GENERAL CONTRACTOR BASED ON FINAL EQUIPMENT SIZES.

4. PROVIDE MANUAL BALANCE DAMPERS IN ALL SUPPLY DUCT BRANCH TAPS DOWNSTREAM OF VAV BOXES.

5. PROVIDE MANUAL BALANCE DAMPERS IN ALL EXHAUST DUCT BRANCH TAPS.

6. PROVIDE TRANSFER "Z" BOOT DUCTS IN FULL HEIGHT WALLS WHERE A PLENUM RETURN SYSTEM IS UTILIZED. BOOTS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 400 FPM. PROVIDE A GRILLE FOR ALL TRANSFERS IN EXPOSED AREAS. RE: ARCH. OPENINGS OF "Z" BOOT DUCTS SHALL BE AT LEAST 12" CLEAR OF STRUCTURE.

7. COORDINATE SPACE TEMPERATURE SENSORS AND THERMOSTAT LOCATIONS TO ALIGN VERTICALLY WITH LIGHT SWITCHES.

GENERAL NOTES:8. TEMPERATURE CONTROLS CONTRACTOR SHALL SUBMIT PLANS INDICATING ALL SPACE TEMPERATURE SENSORS, T-STATS, HUMIDITY SENSORS, ETC. AS PART OF SUBMITTAL PROCESS FOR A/E REVIEW PRIOR TO ROUGH-IN.

9. PROVIDE THROUGH FACE BALANCING FOR ALL DIFFUSERS, REGISTERS, AND GRILLES ABOVE INACCESSIBLE AREAS.

10. PROVIDE TURNING VANES IN ALL 90° DUCT ELBOWS.

11. INSTALL EXPOSED DUCTWORK AS HIGH AS POSSIBLE.

13. ALL DUCT/PIPE PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS SHALL BE CAULKED AND SEALED TO MEET THE RATING REQUIRED. REFER TO LIFE SAFETY DRAWINGS FOR FIRE/SMOKE RATING REQUIREMENTS.

14. PROVIDE ISOLATION VALVES AT EACH BRANCH LINE OFF OF RISER.

15. PROVIDE 3/4" BRANCH PIPING TO ALL TERMINAL UNITS, UNLESS NOTED OTHERWISE.

16. PROVIDE CONDENSATE DRAIN FROM ALL CHILLED WATER COILS AND DX EVAPORATOR COILS TO LAVATORY TAIL PIECE OR MECHANICAL ROOM FLOOR DRAIN. PROVIDE CONDENSATE PUMP FOR WALL MOUNTED UNITS AND CONCEALED UNITS THAT CANNOT BE GRAVITY DRAINED TO TERMINATION LOCATION

KEYNOTES

M2 SA DUCT DOWN.

M5 RA DUCT DOWN.

M30 MECHANICAL CONDENSATE PIPINGDOWN.

M31 SUPPLY AIR TO SIDE DISCHARGEPLENUM CURB BELOW ROOF TOPUNIT.

M32 RETURN AIR TO SIDE DISCHARGEPLENUM CURB BELOW ROOF TOPUNIT.

M33 ROOF TOP UNIT ON SPRING ISOLATEDSIDE DISCHARGE PLENUM CURB.

M34 COORDINATE ACCESS TO RTU WITHBOLLARDS.

Page 13: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

POINTS LISTSYSTEM: MISCELLANEOUS POINTS

POINT DESCRIPTION

FIRE ALARM

OUTSIDE AIR - DB

OUTSIDE AIR - WB

SUMP PUMPS - HIGH WATER

SUMP PUMPS - STATUS

GENERAL NOTES:

1. NOT ALL VIRTUAL POINTS ARE INDICATED.

2. PROVIDE ALL POINTS REQUIRED TO ACHIEVE SEQUENCE OF OPERATION.

3. COORDINATE COMMUNICATION REQUIREMENTS FOR ELECTRICAL MONITORING WITH ELECTRICAL

TY

PE

DI

AI

AI

DI

DI

GR

AP

HIC

X

X

X

X

X

ALA

RM

H

F

TR

EN

D

CONV

5MIN

5MIN

COV

COV

REMARKS

REFERENCE

REFERENCE

EACH SUMP

EACH SUMP

SEQUENCE OF OPERATION GENERAL NOTES:

A GENERAL NOTES/LEGEND AND SEQUENCE OF OPERATIONNO SCALE

B DX SPLIT SYSTEM & HEAT PUMP CONTROLNO SCALE

D ELECTRIC UNIT HEATER DETAILNO SCALE

C VAV TERMINAL UNIT CONTROLNO SCALE

T

POINTS LISTPOINTS LIST

POINTS LIST

POINT DESCRIPTION

SPACE TEMPERATURE - SET POINT

SPACE TEMPERATURE

GENERAL NOTES:

1. NOT ALL VIRTUAL POINTS ARE INDICATED.

2. PROVIDE ALL POINTS REQUIRED TO ACHIEVE SEQUENCE OF OPERATION.

TY

PE

AI

AI

GR

AP

HIC

X

XA

LA

RM

H/L

TR

EN

D

5MIN

5MIN

REMARKS

FLOAT SWITCH IN DRAIN PAN DI H COV INTERLOCK WITH UNIT FOR SHUT DOWN

SYSTEM:

POINT DESCRIPTION

SPACE TEMPERATURE - SET POINT

SPACE TEMPERATURE

GENERAL NOTES:

1. NOT ALL VIRTUAL POINTS ARE INDICATED.

2. PROVIDE ALL POINTS REQUIRED TO ACHIEVE SEQUENCE OF OPERATION.

TY

PE

AI

AI

GR

AP

HIC

X

X

ALA

RM

H/L

TR

EN

D

5MIN

5MIN

REMARKS

SYSTEM: VAV BOX

POINT DESCRIPTION

ELECTRIC HEATER CONTROLLER

GENERAL NOTES:

1. NOT ALL VIRTUAL POINTS ARE INDICATED.

2. PROVIDE ALL POINTS REQUIRED TO ACHIEVE SEQUENCE OF OPERATION.

TY

PE

AO

AO

AI

GR

AP

HIC

X

X

ALA

RM

TR

EN

D

REMARKS

5MIN

5MIN

DAMPER POSITION INDICATOR

CONTROL DAMPER

SPACE TEMPERATURE AI X H/L 5MIN

X

DISCHARGE TEMPERATURE AI X H/L 5MIN

CONTROL SYMBOL LEGEND

AITESPACESENSORS

CONTROL SEQUENCE

A. THE DX SPLIT SYSTEM SHALL BE OPERATED AND CONTROLLED BY THE MANUFACTURER'S

CONTROLS. THE OWNER SHALL HAVE THE ABILITY TO SET THE SPACE TEMPERATURE SETPOINT

REMOTELY THROUGH THE BMS.THE BMS SHALL MONITOR THE SPACE TEMPERATURE AND

ALARM THE BMS WHEN SPACE TEMPERATURE IS OUT OF RANGE.

A. BMS CONTRACTOR SHALL COORDINATE ALL INTERFACE REQUIREMENTS.

B. ALTHOUGH EACH SEPARATE CONTROL DIAGRAM INDICATES AN OUTDOOR AIR

TEMPERATURE SENSOR AND OUTDOOR AIR HUMIDITY SENSOR, TC CONTRACTOR MAY

UTILIZE ONE OF EACH SENSOR AS A COMMON INPUT TO THE SYSTEM. COORDINATE

LOCATION WITH ARCHITECT/ENGINEER PRIOR TO INSTALLATION.

C. PROVIDE INDIVIDUAL INPUTS OR OUTPUTS FOR EACH POINT LISTED IN THE POINTS LISTS.

PROVIDE ANY ADDITIONAL POINTS NOT LISTED IN THE POINTS LIST, BUT REQUIRED TO

MEET THE SEQUENCES OF OPERATION, AT NO ADDITIONAL COST TO THE OWNER. ALL

ANALOG OUTPUTS SHALL BE 4-20MA, 0-10VDC OR 0-20VDC UNLESS OTHERWISE

INDICATED. AO=ANALOG OUTPUT, AI=ANALOG INPUT, DO=DIGITAL (BINARY)

OUTPUT, DI=DIGITAL (BINARY) INPUT.

C. ALL SETPOINTS SHALL BE FULLY ADJUSTABLE AT THE OPERATOR WORKSTATION.

D. PROVIDE OVERRIDE CONTROL OF ALL POINTS AT THE OPERATOR WORKSTATION.

E. ALL CONTROL DIAGRAMS ARE IN EXTENSION OF THE EXISTING BASE BUILDING BMS.

F. BMS/ATC CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING ALL OWNER

STANDARDS. ANY MODIFICATIONS REQUIRED IN ORDER TO MEET THE OWNER

STANDARDS AT A LATER DATE SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER

OR THE PROJECT. REFER TO THE SPECIFICATIONS FOR OPERATOR WORKSTATION

REQUIREMENTS.

GENERAL

OCCUPANCY SCHEDULES:

A. THE BUILDING SHALL HAVE OCCUPIED AND UNOCCUPIED MODES THAT CAN BE SCHEDULED ON

A DAILY BASIS.

B. SCHEDULE SHALL BE ABLE TO BE SCHEDULED BY THE OPERATOR.

HIGH PRESSURE STEAM FLOW METER

=CT

DSP =

DPL =

DAT

DP

=

=

AVS =

CURRENT TRANSMITTER

HEAT RECOVERY COILDISCHARGE STATIC PRESSURE SENSOR

DIFFERENTIAL PRESSURE LOW

DISCHARGE AIR TEMPERATURE

DIFFERENTIAL PRESSURE HIGH

HRC =

MAT

OAD OUTSIDE AIR DAMPER

MOTOR STARTER

MIXED AIR TEMPERATURE

=

M =

=

EXHAUST AIR VALVE

FLOW INDICATOR

AIR VELOCITY SENSOR

FI

EAV

=

=

HPSF

HUMIDITY SENSORHS =

=

=

SAV = SUPPLY AIR VALVE

VFV VARIABLE FREQUENCY INPUT VALVE=

RAT

SDPR

S/S

=

=

=

PH = PH METER

RETURN AIR TEMPERATURE

SMOKE DAMPER

START - STOP

ST

SCV

STEAM TEMPERATURE=

STEAM CONTROL VALVE=

FLOW ELEMENTFE =

FLOW TRANSMITTERFT =

HAND OFF AUTOHOA

IT = CURRENT TRANSMITTER

PSH PRESSURE SENSOR HIGH=

SC = SPEED CONTROLER

AO

I/P CURRENT TO PNEUMATIC RELAY

ANALOG INPUT

ANALOG OUTPUT

ELECTRIC TO PNEUMATICEP =

=

AI =

=

DI

DO

DIGITAL INPUT

DIGITAL OUTPUT=

=CO =

CD =

CARBON DIOXIDE SENSOR

CONTROL DAMPER

END SWITCHES =

FLOW METER=FMMOISTURE TRANSMITTERMT =

DIFFERENTIAL PRESSURE INDICATORPDI =

DIFFERENTIAL PRESSURE TRANSMITTERPDT =

PRESSURE SENSOR LOWPSL =

SDD DUCT SMOKE DETECTOR=

2

C = CONTACT

=TE TEMPERATURE ELEMENT

FO FAIL OPEN=

FC FAIL CLOSED=

PRESSURE TRANSMITTER=PT

STATUSS =

RH = REHEAT COIL

CC = COOLING COIL

AFS = AIR FLOW MEASURING STATION

HUMIDITY SENSOR HIGH LIMITHSH =

=CV CONTROL VALVE

F FAULT=

GENERAL EXHAUST VALVEGEV =

HEATING COILHC =

RAD = RETURN AIR DAMPEREPO EMERGENCY POWER OFF=

EC

START/STOP

SF

SA

ELECTRIC UNIT HEATER TEMPERATURE CONTROL

A. THE UNIT HEATER IS CONTROLLED BY A SPACE THERMOSTAT.

B. LOCAL CONTROLLER SHALL CYCLE FAN & ENERGIZE ELECTRIC HEAT TO MAINTAIN SPACE

SETPOINT.

SPACETHERMOSTAT

AI

TE

SA

AI

CD

AO

CD

AITEHC

AO

SPACE TEMPERATURE

A. CONFIGURATION: REFER TO SCHEDULE.

VAV TERMINAL UNIT CONTROL:

B. OCCUPIED MODE: 1. WHEN THE AHU IS IN THE OCCUPIED MODE, THE PRIMARY AIR DAMPER AND ELECTRIC HEAT SHALL

C. UNOCCUPIED MODE: 1. WHEN THE AHU IS IN THE UNOCCUPIED MODE, THE UNIT SHALL BE OFF AND HEATING SHALL BE

MODULATE IN SEQUENCE TO MAINTAIN SPACE TEMPERATURE SETPOINT

DEACTIVATED.

D. NIGHT SETBACK MODE: 1. TERMINAL UNIT SHALL OPERATE NORMALLY WHEN AHU IS IN OPERATIONE. MORNING WARM-UP MODE: 1. PRIMARY AIR VALVES SHALL BE AT MINIMUM POSITION AND ELECTRIC HEAT ACTIVATED. 2. REVERT TO OCCUPIED MODE WHEN ALL SPACE STATS HAVE REACHED OCCUPIED HEATING SETPOINT.F. ELECTRIC HEAT CONTROL: 1. THE HEATING STAGES SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT.THE HEATING

SHALL BE DEACTIVATED IF THE PRIMARY AIR DAMPERS ARE OPEN PAST THEIR MINIMUM POSITION. THE HEATINGSHALL BE DEACTIVATED IF THE AHU FAN IS OFF.

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:44

:00

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M6.00

MECHANICAL CONTROLDIAGRAM

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1/8" = 1'-0" 2MEC CONTROLS - Dependent 2

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 14: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

EXHAUST FANS:

VAV AIR HANDLING UNIT:

VAV AIR HANDLING UNIT:

B EXHAUST FANS

NO SCALE

A ROOFTOP UNIT CONTROL

NO SCALE

C AHU C-1

NO SCALE

SYSTEM POINTS LIST

EXHAUST FAN

SYSTEM POINT DESCRIPTION

INPUT

ANALOG

OUTPUT

BINARY

INPUT OUTPUT ALARMS

NOTES

SYSTEM POINTS LIST

VAV AIR HANDLER WITH OA TRACKING

SYSTEM POINT DESCRIPTION

ANALOG

INPUT OUTPUT

BINARY

INPUT OUTPUT ALARMS

SYSTEM POINTS LIST

AIR HANDLER WITH OA TRACKING

SYSTEM POINT DESCRIPTION

ANALOG

INPUT OUTPUT

BINARY

INPUT OUTPUT ALARMS

S

T

CO2

T T

EXHAUST FANS

INTERLOCKED DAMPERS (2-POSITION)

GENERAL NOTES:G

RA

PH

IC

X

1. SEE SCHEDULES FOR QUANTITIES

2. POINTS ABOVE ARE NOT NECESSARILY REFLECTED IN CONTROL DIAGRAMS.T

EM

PE

RA

TU

RE

PR

ES

SU

RE

RE

LA

TIV

E H

UM

IDIT

YK

WG

PM

CF

MP

PM

PE

RC

EN

TP

ER

CE

NT

RLA

DD

C (

4-2

0 M

A,

0-1

0 V

DC

)

SE

TP

OIN

T A

DJ.

ST

AT

US

ON

/OF

F

X

ALA

RM

ST

AT

US

ST

AT

US

OP

EN

/CLS

D.

ST

AT

US

RE

LA

Y

TIM

ED

OV

ER

RID

E

OF

F/O

N

X

OP

EN

/CLO

SE

D

X

LO

CK

OU

TE

NA

BLE

/DIS

AB

LE

LIM

IT W

AR

NIN

GH

IGH

AN

ALO

GLO

W A

NA

LO

GB

INA

RY

PR

OO

FS

EN

SO

R F

AIL

FLO

W F

AIL

CO

MM

FA

IL

X

DIA

GN

OS

TIC

SF

LO

W O

VE

RR

IDE

X

3. PROVIDE ADDITIONAL POINTS REQUIRED IN DIAGRAMS OR SEQUENCES.

CONTROL PANEL

SUPPLY AIR FAN

SUPPLY AIR FAN VFD

SUPPLY AIR TEMPERATURE

BUILDING STATIC PRESSURE

COOLING (EACH STAGE)

OA DAMPER

SMOKE DETECTOR CONTACTS

SPACE TEMPERATURE

AHU ALARM STATUS

TIMED OVERRIDE

OUTSIDE AIR TEMPERATURE

RELIEF AIR DAMPER

GENERAL NOTES:

GR

AP

HIC

X

1. SEE SCHEDULES FOR QUANTITIES

TE

MP

ER

AT

UR

E

X

X

X

PR

ES

SU

RE

X

RE

LA

TIV

E H

UM

IDIT

YK

WG

PM

CF

MP

PM

PE

RC

EN

T

X

X

PE

RC

EN

T R

LA

DD

C (

4-2

0 M

A,

0-1

0 V

DC

)

X

X

SE

TP

OIN

T A

DJ.

X

RE

FR

IGE

RA

NT

ST

AT

US

ON

/OF

F

X

FIL

TE

R S

TA

TU

S

ST

AT

US

OP

EN

/CLS

D.

ST

AT

US

ALA

RM

X

2

X

TIM

ED

OV

ER

RID

E

X

OF

F/O

N

X

OP

EN

/CLO

SE

DLO

CK

OU

TE

NA

BLE

/DIS

AB

LE

LIM

IT W

AR

NIN

GH

IGH

AN

ALO

G

X

X

X

LO

W A

NA

LO

G

X

X

X

BIN

AR

Y

2

PR

OO

FS

EN

SO

R F

AIL

X

X

X

X

X

FLO

W F

AIL

CO

MM

FA

IL

X

X

DIA

GN

OS

TIC

S

X

FLO

W O

VE

RR

IDE

X

X

X

X

X

X

X

X

X

X

X

X

2. SMOKE DETECTOR HARD WIRED FOR FAN SHUT-DOWN AND FIRE ALARM.

3. PROVIDE ADDITIONAL POINTS REQUIRED IN DIAGRAM OR SEQUENCE.

NOTIFICATION PER SECTION DIV 23 & 26.

X XX

CARBON DIOXIDE SENSOR XX

X

CONTROL PANEL

SUPPLY FAN

SUPPLY AIR TEMPERATURE

HEATING CONTROLLER

COOLING (EACH STAGE)

OA DAMPER

SPACE TEMPERATURE

AHU ALARM STATUS

TIMED OVERRIDE

OUTSIDE AIR TEMPERATURE

RELIEF AIR DAMPER

GENERAL NOTES:

GR

AP

HIC

X

1. SEE SCHEDULES FOR QUANTITIES

TE

MP

ER

AT

UR

E

X

X

X

PR

ES

SU

RE

RE

LA

TIV

E H

UM

IDIT

YK

WG

PM

CF

MP

PM

PE

RC

EN

T

X

PE

RC

EN

T R

LA

DD

C (

4-2

0 M

A,

0-1

0 V

DC

)

X

SE

TP

OIN

T A

DJ.

X

RE

FR

IGE

RA

NT

ST

AT

US

ON

/OF

F

X

FIL

TE

R S

TA

TU

S

ST

AT

US

OP

EN

/CLS

D.

ST

AT

US

ALA

RM

X

TIM

ED

OV

ER

RID

E

X

OF

F/O

N

OP

EN

/CLO

SE

DLO

CK

OU

TE

NA

BLE

/DIS

AB

LE

LIM

IT W

AR

NIN

GH

IGH

AN

ALO

G

X

X

LO

W A

NA

LO

G

X

X

BIN

AR

YP

RO

OF

SE

NS

OR

FA

IL

X

X

X

X

FLO

W F

AIL

CO

MM

FA

IL

X

X

DIA

GN

OS

TIC

SF

LO

W O

VE

RR

IDE

X

X

X

X

X

X

X

X

X

X

2. SMOKE DETECTOR HARD WIRED FOR FAN SHUT-DOWN AND FIRE ALARM.

3. PROVIDE ADDITIONAL POINTS REQUIRED IN DIAGRAM OR SEQUENCE.

NOTIFICATION PER SECTION DIV 23 & 26.

X

X

X

X

X

X

X

XX XRETURN AIR DAMPER

RELIEF AIR FAN X XX

DUCT STATIC PRESSURE X X X XX

RELIEF AIR FAN

RELIEF AIR FAN VFD X X

X

X X

X

X

X

X

ECONOMIZER MODE DAMPER XX X

FILTER DIFFERENTIAL PRESSURE X X X XX

SUPPLY AIR FLOWRATE X X X X X

OUTSIDE AIR FLOWRATE X X X X X

RELIEF AIR FLOWRATE X X X X X

RTU C-1

UNIT OUTSIDE AIRSETPOINT (CFM)

OUTSIDE AIRSETPOINT (CFM)

MINIMUM

RTU G-1

2,500

1,300

500

400

X

EA

EA

EXHAUST FAN

S/S

CSEN

DI

A. FAN SHALL OPERATE DURING OCCUPIED HOURS. DURING OCCUPIED HOURS,

EXHAUST DAMPER SHALL OPEN AND EXHAUST FAN SHALL BE ENERGIZED. FAN SHALL

DE-ENERGIZE WHEN SYSTEM IS IN UNOCCUPOED MODE.

B. SYSTEM CAN BE MANUALLY ENERGIZED BY MANUAL OVERRIDE SWITCH.

C. MONITORED BY BMS.

DO

M

2-POSITION LOW LEAKDAMPER INTERLOCKEDWITH FAN CIRCUIT.DAMPER(S) ARE OPENWHEN FAN IS ON.

DO

MANUALOVERRIDESWITCH WHEREINDICATED

AI

OA

AO

M

TTA

SF

CSEN

TT

DI

SD

DI AI AO

S

AI

DPT

SPACE

SPT

DI

VFDAO

DI

DO

AI

OUTSIDE AIR

F

AI

SA

HARD WIRE TO FANSTART CIRCUIT

DX

CC

A. CONFIGURATION, RE: SCHEDULE

B. OCCUPIED MODE:

1. WHEN THE AHU IS IN THE OCCUPIED MODE, THE SUPPLY FANS SHALL OPERATE

CONTINUOUSLY. THE SUPPLY FAN VFD SHALL MODULATE TO MAINTAIN THE DUCT STATIC

PRESSURE. DX COOLING AND HOT GAS REHEAT SHALL MODULATE TO MAINTAIN SPACE

TEMPERATURE (ADJ) AND HUMIDITY (ADJ).

C. UNOCCUPIED MODE

1. WHEN THE AHU IS IN THE UNOCCUPIED MODE, THE SUPPLY FANS SHALL BE OFF. THE

OUTSIDE AIR DAMPER SHALL BE CLOSED, AND DX COOLING SHALL BE DE-ENERGIZED.

D. FAN SAFETY CONTROLS:

1. DE-ENGERGIZE THE SUPPLY FANS WHENEVER EITHER SMOKE DETECTOR HAS

TRIPPED OR A FAN STATUS INDICATES A FAILURE (AFTER A TWO MINUTE DELAY). THE

SMOKE DETECTORS AND THE FAN FAILAURES REQUIRE A MANUAL RESET.

2. DE-ENERGIZE THE SUPPLY FANS WHEN THE DISCHARGE STATIC PRESSURE HIGH-LIMIT

REACHES 1.5 INCHES WC (ADJ).

3. ALARM THE BMS WITH THE APPROPRIATE ALARM MESSAGE.

F. TIMED OVERRIDE

1. PROVIDE A TWO HOUR TIMED OVERRIDE VIA SWITCH AT SPACE SENSORS TO RETURN RTU

TO OCCUPIED MODE.

G. ECONOMIZER OPERATION

1. WHEN THE DIFFERENCE BETWEEN THE OA ENTHALPY AND THE REQUIRED SA ENTHALPY IS LESS THANTHE DIFFERENCE BETWEEN RA AND SA ENTHALPY, THE AHU CONTROLS SHALL ENABLE

H. DX COOLING COIL CONTROL

1. THE CONDENSING UNIT SHALL MODULATE TO MAINTAIN THE DAT. THE CONDENSING UNIT

SHALL BE DE-ENERGIZED IF THE AHU IS IN HEATING MODE, THE FANS ARE OFF, OR THE

DISCHARGE AIR SENSORS HAVE FAILED.

M

INTAKE HOOD DAMPER

E. VFD CONTROL

1. WHEN THE SUPPLY FAN IS ENERGIZED, THE VFD SHALL SLOWLY RAMP UP TO SETPOINT AND

MODULATE THE OA DAMPER TO MAINTAIN THE PROPER BUILDING STATIC PRESSURE SETPOINT (0.05",

ADJUSTABLE). REFER TO FLOOR PLANS FOR STATIC PRESSURE SENSOR LOCATIONS.

A0

M

BUILDING STATICPRESSURE SENSOR

THE ECONOMISER MODE. THE BAS SHALL CONTINOUSLY MONITOR THE OA, SA & RA ENTHALPY IN

ORDER TO ACTIVATE THE OPERATING MODE THAT IS MOST ENERGY EFFICIENT.

AITE

SPACE TEMPERATURE

RA

AI

AI

OA

A0

M

TTA

SF

CSEN

TT

DI

SPT

DI

AI

OUTSIDE AIR

F

SA

DX

CC

ELECTRIC

HC

A. CONFIGURATION, RE: SCHEDULE

B. OCCUPIED MODE:

1. WHEN THE FCU IS IN THE OCCUPIED MODE, THE SUPPLY FANS SHALL OPERATE

CONTINUOUSLY. THE SUPPLY FAN VFD SHALL MODULATE TO MAINTAIN THE DUCT STATIC

PRESSURE. DX COOLING SHALL MODULATE TO MAINTAIN SPACE

TEMPERATURE (ADJ) AND HUMIDITY (ADJ). THE ELECTRIC HEATING SHALL

MODULATE IN SEQUENCE TO MAINTAIN SPACE TEMPERATURE (ADJ). ELECTRIC

HEATING AND DX COOLING SHALL NOT OPERATE SIMULTANEOUSLY.

C. UNOCCUPIED MODE

1. WHEN THE FCU IS IN THE UNOCCUPIED MODE, THE SUPPLY FANS SHALL BE OFF. THE

OUTSIDE AIR DAMPER SHALL BE CLOSED, DX COOLING SHALL BE DE-ENERGIZED, AND

ELECTRIC HEATING SHALL BE DE-ENERGIZED.

D. FAN SAFETY CONTROLS:

1. DE-ENGERGIZE THE SUPPLY FANS WHENEVER EITHER SMOKE DETECTOR HAS

TRIPPED OR A FAN STATUS INDICATES A FAILURE (AFTER A TWO MINUTE DELAY). THE

SMOKE DETECTORS AND THE FAN FAILAURES REQUIRE A MANUAL RESET.

2. DE-ENERGIZE THE SUPPLY FANS WHEN THE DISCHARGE STATIC PRESSURE HIGH-LIMIT

REACHES 1.0 INCHES WC (ADJ).

3. ALARM THE BMS WITH THE APPROPRIATE ALARM MESSAGE.

E. TIMED OVERRIDE

1. PROVIDE A TWO HOUR TIMED OVERRIDE VIA SWITCH AT SPACE SENSORS TO RETURN RTU

TO OCCUPIED MODE.

F. ECONOMIZER OPERATION

1. WHEN THE DIFFERENCE BETWEEN THE OA ENTHALPY AND THE REQUIRED SA ENTHALPY IS LESS THANTHE DIFFERENCE BETWEEN RA AND SA ENTHALPY, THE FCU CONTROLS SHALL ENABLE

G. DX COOLING COIL CONTROL

1. THE CONDENSING UNIT SHALL MODULATE TO MAINTAIN THE DAT. THE CONDENSING UNIT

SHALL BE DE-ENERGIZED IF THE FCU IS IN HEATING MODE, THE FANS ARE OFF, OR THE

DISCHARGE AIR SENSORS HAVE FAILED.

THE ECONOMIZER MODE. THE BAS SHALL CONTINOUSLY MONITOR THE OA, SA & RA ENTHALPY IN

ORDER TO ACTIVATE THE OPERATING MODE THAT IS MOST ENERGY EFFICIENT.

RA

A0

M

EA

A0

M

MIXINGPLENUM

M

AO

RELIEFAIR

M

RELIEFAIR

2. RETURN AIR DAMPER WILL CLOSE AND RELIEF EXHAUST DAMPER SHALL OPEN. RELIEF EXHAUST

FAN SHALL MODULATE TO MAINTAIN PROPER STATIC PRESSURE SETPOINT (0.05", ADJ.).

VFDAO

DI

DO

AI

DP

LOCATE 2_3 OF THE

WAY DOWN THE

LONGEST DUCT RUN.

AI

SPACE TEMPERATURE

AI

AFS

AI

AFS

AI

AFS

I. DEMAND CONTROL VENTILATION.

1. THE CONTROLLER SHALL MONITOR RETURN AIR CO2 CONCENTRATION.

2. IF THE CO2 LEVEL FOR RETURN AIR EXCEED 850 PPM (ADJ.), ALARM THE BMS.

3. INCREASE OUTSIDE AIR QUANTITIES (SUBJECT TO MAINTAINING LEAVING AIR TEMPERATURE) TO

4. IF RETURN AIR CO2 IS BELOW 700 PPM (ADJ.), AND RELIEF DAMPERS ARE NOT CLOSED, MINIMUM

MAINTAIN 850 PPM IN RETURN AIR DUCT.

OUTSIDE AIR SETPOINT SHALL BE INCREMENTALLY REDUCED. SET POINT TO RAISE IF CO2 LEVELS

RISE ABOVE 750 PPM (ADJ.) OR IF SPACE STATIC PRESSURE CANNOT BE MAINTAINED. REFER TO

SCHEDULE BELOW FOR LOWEST MINIMUM OUTSIDE AIR.

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:44

:00

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M6.01

MECHANICAL CONTROLDIAGRAM

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1/8" = 1'-0" 1MEC CONTROLS - Dependent 1

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 15: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

VAV AIR HANDLING UNIT:

A AHU C-2

NO SCALE

SYSTEM POINTS LIST

VAV AIR HANDLER WITH OA TRACKING

SYSTEM POINT DESCRIPTION

ANALOG

INPUT OUTPUT

BINARY

INPUT OUTPUT ALARMS

T

CO2

CONTROL PANEL

SUPPLY AIR FAN

SUPPLY AIR FAN VFD

SUPPLY AIR TEMPERATURE

BUILDING STATIC PRESSURE

COOLING (EACH STAGE)

OA DAMPER

SMOKE DETECTOR CONTACTS

SPACE TEMPERATURE

AHU ALARM STATUS

TIMED OVERRIDE

OUTSIDE AIR TEMPERATURE

RETURN AIR DAMPER

GENERAL NOTES:

GR

AP

HIC

X

1. SEE SCHEDULES FOR QUANTITIES

TE

MP

ER

AT

UR

E

X

X

X

PR

ES

SU

RE

X

RE

LA

TIV

E H

UM

IDIT

YK

WG

PM

CF

MP

PM

PE

RC

EN

T

X

X

PE

RC

EN

T R

LA

DD

C (

4-2

0 M

A,

0-1

0 V

DC

)

X

X

SE

TP

OIN

T A

DJ.

X

RE

FR

IGE

RA

NT

ST

AT

US

ON

/OF

F

X

FIL

TE

R S

TA

TU

S

ST

AT

US

OP

EN

/CLS

D.

ST

AT

US

ALA

RM

X

2

X

TIM

ED

OV

ER

RID

E

X

OF

F/O

N

X

OP

EN

/CLO

SE

DLO

CK

OU

TE

NA

BLE

/DIS

AB

LE

LIM

IT W

AR

NIN

GH

IGH

AN

ALO

G

X

X

X

LO

W A

NA

LO

G

X

X

X

BIN

AR

Y

2

PR

OO

FS

EN

SO

R F

AIL

X

X

X

X

X

FLO

W F

AIL

CO

MM

FA

IL

X

X

DIA

GN

OS

TIC

S

X

FLO

W O

VE

RR

IDE

X

X

X

X

X

X

X

X

X

X

X

X

2. SMOKE DETECTOR HARD WIRED FOR FAN SHUT-DOWN AND FIRE ALARM.

3. PROVIDE ADDITIONAL POINTS REQUIRED IN DIAGRAM OR SEQUENCE.

NOTIFICATION PER SECTION DIV 23 & 26.

X XX

X

RETURN AIR FAN

RETURN AIR FAN VFD X X

X

X X

X

X

X

X

ECONOMIZER MODE DAMPER XX X

FILTER DIFFERENTIAL PRESSURE X X X XX

SUPPLY AIR FLOWRATE X X X X X

OUTSIDE AIR FLOWRATE X X X X X

RETURN AIR FLOWRATE X X X X X

AHU C-2

UNIT OUTSIDE AIRSETPOINT (CFM)

OUTSIDE AIRSETPOINT (CFM)

MINIMUM

3,000 600

CARBON DIOXIDE SENSOR XX X

ELECTRIC DUCT HEATER X XX

SUPPLY AIR TEMPERATURE (HEATING) X X X XX

AI

OA

AO

M

TTA

SF

CSEN

TT

DI

SD

DI AI AO

S

AI

DPT

SPACE

VFDAO

DI

DO

AI

OUTSIDE AIR

F

AI

SA

HARD WIRE TO FANSTART CIRCUIT

DX

CC

A. CONFIGURATION, RE: SCHEDULE

B. OCCUPIED MODE:

1. WHEN THE AHU IS IN OCCUPIED MODE, THE SUPPLY AND RETURN FANS SHALL OPERATE

CONTINUOUSLY. THE SUPPLY AND RETURN VFD'S SHALL MODULATE SIMULTANEOUSLY

TO REACH DESIGN FLOW RATE. FANS SHALL RAMP UP SLOWLY. DX COIL SHALL MODULATE TO

MAINTAIN SPACE TEMPERATURE (ADJ.) AND HUMIDITY (ADJ.). ELECTRIC DUCT HEATER SHALL

C. UNOCCUPIED MODE

1. WHEN THE AHU IS IN THE UNOCCUPIED MODE, THE SUPPLY AND RETURN FANS SHALL BE OFF. THE

OUTSIDE AIR DAMPER SHALL BE CLOSED, AND DX COOLING SHALL BE DE-ENERGIZED.

D. FAN SAFETY CONTROLS:

1. DE-ENGERGIZE THE SUPPLY FANS WHENEVER EITHER SMOKE DETECTOR HAS

TRIPPED OR A FAN STATUS INDICATES A FAILURE (AFTER A TWO MINUTE DELAY). THE

SMOKE DETECTORS AND THE FAN FAILAURES REQUIRE A MANUAL RESET.

2. DE-ENERGIZE THE SUPPLY FANS WHEN THE DISCHARGE STATIC PRESSURE HIGH-LIMIT

REACHES 3.0 INCHES WC (ADJ).

3. ALARM THE BMS WITH THE APPROPRIATE ALARM MESSAGE.

F. TIMED OVERRIDE

1. PROVIDE A TWO HOUR TIMED OVERRIDE VIA SWITCH AT SPACE SENSORS TO RETURN RTU

TO OCCUPIED MODE.

G. ECONOMIZER OPERATION

1. WHEN THE DIFFERENCE BETWEEN THE OA ENTHALPY AND THE REQUIRED SA ENTHALPY IS LESS THANTHE DIFFERENCE BETWEEN RA AND SA ENTHALPY, THE AHU CONTROLS SHALL ENABLE

H. DX COOLING COIL CONTROL

1. THE CONDENSING UNIT SHALL MODULATE TO MAINTAIN THE DAT. THE CONDENSING UNIT

SHALL BE DE-ENERGIZED IF THE AHU IS IN HEATING MODE, THE FANS ARE OFF, OR THE

DISCHARGE AIR SENSORS HAVE FAILED.

E. VFD CONTROL

1. WHEN THE SUPPLY AND RETURN FANS ARE ENERGIZED, THE VFD'S SHALL SLOWLY RAMP UP TO SETPOINT AND

MODULATE THE OA DAMPER TO MAINTAIN THE PROPER BUILDING STATIC PRESSURE SETPOINT (0.05",

ADJUSTABLE). REFER TO FLOOR PLANS FOR STATIC PRESSURE SENSOR LOCATIONS.

A0

M

BUILDING STATICPRESSURE SENSOR

THE ECONOMISER MODE. THE BAS SHALL CONTINOUSLY MONITOR THE OA, SA & RA ENTHALPY IN

ORDER TO ACTIVATE THE OPERATING MODE THAT IS MOST ENERGY EFFICIENT.

AITE

SPACE TEMPERATURE

RA

AI

M

AOM

RELIEFAIR

2. RETURN AIR DAMPER WILL CLOSE AND RELIEF EXHAUST DAMPER SHALL OPEN. RELIEF EXHAUST

FAN SHALL MODULATE TO MAINTAIN PROPER STATIC PRESSURE SETPOINT (0.05", ADJ.).

VFDAO

DI

DO

AI

DP

AI

AFS

AI

AFS

RF

I. DEMAND CONTROL VENTILATION.

1. THE CONTROLLER SHALL MONITOR RETURN AIR CO2 CONCENTRATION.

2. IF THE CO2 LEVEL FOR RETURN AIR EXCEED 850 PPM (ADJ.), ALARM THE BMS.

3. INCREASE OUTSIDE AIR QUANTITIES (SUBJECT TO MAINTAINING LEAVING AIR TEMPERATURE) TO

4. IF RETURN AIR CO2 IS BELOW 700 PPM (ADJ.), AND RELIEF DAMPERS ARE NOT CLOSED, MINIMUM

MAINTAIN 850 PPM IN RETURN AIR DUCT.

OUTSIDE AIR SETPOINT SHALL BE INCREMENTALLY REDUCED. SET POINT TO RAISE IF CO2 LEVELS

RISE ABOVE 750 PPM (ADJ.) OR IF SPACE STATIC PRESSURE CANNOT BE MAINTAINED. REFER TO

SCHEDULE BELOW FOR LOWEST MINIMUM OUTSIDE AIR.

ELECTRIC

DUCT HEATER

AI

TT

MODULATE IN SEQUENCE TO MAINTAIN SPACE TEMPERATURE (ADJ.). ELECTRIC HEATING AND

DX COOLING SHALL NOT OPERATE SIMULTANEOUSLY.

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 9

:23

:49

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M6.02

MECHANICAL CONTROLDIAGRAM

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 16: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

PROVIDE MIN. AIR FLOW & MAINTENANCE ACCESS PER MFR DIRECTIONS:

TYPICAL ALL SIDES & TOP OF UNIT

12

CONDENSING UNIT

COMPRESSOR ACCESS

REFRIGERANT GAUGE CONNECTIONS.

BACK-SEATED REFRIGERANTVALVE.

SIGHT GLASS WITH MOISTURE INDICATOR.

SUCTION LINE WITH INSULATION.

ROOF CAP AND CURB.

CONDUIT - POWER AND CONTROL.

REFRIGERANT LIQUID LINE

FULL PERIMETER ROOF CURB WITH SHEET METAL CAP.

CONDENSER COIL.

FAN GUARD.

VIBRATION ISOLATORS.

FLASH PENETRATION WATER TIGHT SEE DETAIL.

1.

2.

NOTES :

REFRIGERANT LIQUID LINE & SUCTION LINE TO BE SIZED PER MANUFACTURER'S RECOMMENDATIONS.

PROVIDE OIL TRAPS AT RS LOW POINTS AND/OR PITCH HORIZONTAL PIPING FOR PROPER OIL RETURN.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

1

23

4

5

9

6

14

78

10

13

11

3

DETAIL NOTES :

REMOTE CEILINGOPERATOR WHERE

DAMPER ISINACCESSIBLE

AIR FLOW

W

DAMPERS SHOULD NOTBE INSTALLED CLOSERTHAN TWO DUCT WIDTHSTO ELBOWS ORINTERSECTIONS

NOTE:

45

L

VOLUME DAMPERPROVIDE CONCEALEDCEILING DAMPERREGULATOR

L=1/4 W (4" MIN.)

NOTE:

1. ACOUSTICAL TILE CEILING SHOWN. GYP. BOARD CEILING SIMILAR.

NOTES:

SHEET METALBAND

ACOUSTICAL TILECEILING

INSULATED FLEXIBLEDUCT. MAX. 7'

VD

FLUORESCENT COLOREDMARKER TAPE

DUCT INSULATION

CLEANOUTS CAP

SLOPE TO NEAREST FLOORDRAIN (MECHANICAL ROOM)JANITORS CLOSET, OR OTHERAPPROVED RECEPTOR

FAN STATIC PRESSURE +1"DRAIN PAN

GIRANDOLE OR FAN COIL

NOTE:

1. INSULATE CONDENSATE DRAIN WHEN ABOVE CEILINGS.

DRAW THROUGH COIL BLOW THROUGH COIL

A B

SEE NOTE 1 SEE NOTE 2 SEE NOTE 1SEE NOTE 2

AB

DRAIN LINE SHALL BE ATLEAST THE SAME SIZE AS

THE NIPPLE ON THE DRAIN PAN

PITCH DOWNTOWARD DRAIN

AIR HANDLING UNIT

DRAIN PAN

NOTES:1. STATIC PRESSURE OF AIR HANDLING UNIT PLUS 1".

2. 2" MINIMUM.

1"B

A 2"

TOOPEN DRAIN

RECEPTOR ORFLOOR SINK

OPEN TO ATMOSPHERE

EXHAUST AIR DUCT

ACCESS DOOR

ROOF

GRAVITY BACKDRAFTDAMPER

SEE ARCH. DWG. FOR FLASHING DETAILS

PRE-FABRICATED ROOF CURB

1. PROVIDE BACKDRAFT DAMPER AT AN DISCHARGE

UPBLAST

NOTE:

TRUSS ANGLES, TOPCHORD

2X2X1/4" STEEL TEE2 1/2" LONG W/1/2"THICK PLATE WELDEDAT TOP AND BOLTEDTO TRUSS W(2) 3/8"DIA. BOLTS

DUCT SUPPORTAT 10'-0" O.C.@ EACH TRUSS

SECTION A-A

A

STEEL TEEW/PLATE AT TRUSS

DUCT 24" DIA. TO 30"

STRAP

A

SECTION/ELEVATION

NOTE:

1. SEE ARCHITECTURAL DRAWINGS FOR MORE INFORMATION.

1/8" THICK FORMEDGALV. MLT. SADDLE2" W (PLACED OVERSTRAP AND BOLTED

TO TRUSS) W/(2)

16 GA FORMEDGALV METAL BAND1/4" W BOLTED TO

BRACKET & TRUSSW 1/2 DIA. BOLT

4"

SOLDER COUNTER FLASHINGCOLLAR TO COUPLING

FLASHING

MINIMUM 4" OVERLAP

TOP OF ROOFING

ROOF DECK

SEE ARCH. DETAILS FOR ALL FLASHING REQUIREMENTS &MAINTAIN ROOFING WARRANTY

FOR UNITS 5 TONS AND SMALLER

NEOPRENE VIBRATIONISOLATION PAD

OIL TRAP (TYP)

FILTER-DRIER (FORTYPE AND LOCATIONSEE SPEC)

VIBRATION ISOLATOR

SECURE CONDENSINGUNIT TO SUPPORT

EXPANSION VALVE

COOLING COILCONDENSING UNIT

LIFT TRAP (EVERY25 FT. OF RISE) LIQUID SITE GLASS

REVERSE TRAP

SEE PLAN FORCONTINUATIONSLOPE SUCTION LINE

DOWN TOWARDS CONDENSINGUNIT. (TYPICAL)

NOTE:

ROOF

SEE ARCH.DRAWING FORFLASHING AND

ROOFING DETAIL

FACTORYPRE-FABRICATED

LEVELED ROOFCURB

CONTINUOUS UNITSUPPORT MEMBER

EPDM WEATHER SEAL

SPRING ISOLATORHOUSING WITHADJUSTABLE SPRINGSNEOPRENE SPRINGCUPS AND ALLDIRECTIONAL SEISMIC

RESTRAINTS WITH 1/4"THICK NEOPRENEBUSHINGS

CONTINUOUS STEEL RAIL

2x4 WOOD NAILER

STRUCTURAL SUPPORTS(COORDINATE WITHSTRUCTURAL DRAWING)

INSULATION

CONTINUOUSGALVANIZEDSEALER STRIP(TOP AND BOTTOM)

ROOFTOP AC UNIT

CLOSED CELLNEOPRENEAIRSEAL

FOR ANCHORAGEDETAIL, SEE

STRUCTURAL DRAWING

ALLOW FOR ACCESS

BOX OUTLET SIZE

SIZE ON PLAN

CONICAL OR 45°TAP

D

SHEET METAL ELBOW ONLY

2'-0" MAX. STRAIGHT NON-COMPRESSED FLEX DUCT.

ALLOW FOR ACCESS

4'-0" TO FIRST TAKEOFF

4 D

REMOVABLE COREFILTER DRYER

LIQUID DN

HOT GAS

SUCTIONDN

MOISTURE INDICATING SIGHT GLASS

CHARGING/GAUGE/RECOVERY PORT

CONDENSING UNIT

VIBRATION ISOLATION PADS

FULL PERIMETER ROOF CURB W/FLASHING & COUNTER

FLASHING (RE: ARCH. DIV.)

ISOLATION VALVE (TYP)

INSULATE SUCTION LINEPER SPEC.

SIGHT GLASS

DOUBLE RISER ASRECOMMENDED BYMANUFACTURER

ISOLATION VALVE

SEE SPEC. EXPANSION VALVE

SEE SPEC.

EVAPORATOR COIL

INSULATE EXPANSION VALVE BULB

GATE VALVE (TYP)

SIZE AND INSTALL REFRIG. LINESACCORDING TO MANUFACTURER'SSPECIFICATIONS.

1.

2. PROVIDE OIL TRAP AND INVERTED TRAP AT ALL RISERS. ALSO PROVIDEDOUBLE RISER IF NECESSARY FOR PROPER OIL RETURN AT LOWEST STEP OF COMPRESSOR UNLOADING.

PITCH REFRIGERANT LINES INDIRECTION INDICATED @ 1/2" PER 10FT.

3.

ALL CONNECTIONS SHALL BE BRAZEDINCLUDING CONNECTIONS AT COIL AND CONDENSING UNIT.

4.

NOTES:

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:44

:01

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M7.00

MECHANICAL DETAILS

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

NO SCALE1

AIR-COOLED CONDENSING UNIT

NO SCALE2

BRANCH DUCT TAKE-OFF DETAIL

NO SCALE3

CEILING DIFFUSER CONNECTION

NO SCALE4

CONDENSATE DRAIN DETAIL

NO SCALE5

DRAIN AND TRAP FROM AIR HANDALINGUNIT

NO SCALE7

EXHAUST AIR FAN INSTALLATION (FORGENERAL APPLICATION)

NO SCALE6

GYM MAIN DUCT SUPPORT

NO SCALE8

PIPE/ROOF PENETRATION

NO SCALE9

REFRIGERANT PIPING DETAIL

NO SCALE10

ROOFTOP AC UNIT SUPPORT &VIBRATION ISOLATION SYSTEM

NO SCALE11

VAV BOX DETAIL

NO SCALE12

SPLIT SYSTEM AC UNIT DETAIL

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 17: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

ROUND OR RECT.DUCT AS SHOWN

ON PLAN

OPPOSED BLADE DAMPERIF SHOWN ON SCHEDULE

MIN 6" BOOT.WITH LINER

SURFACE MOUNTFRAME

SEE SCHEDULEFOR TYPE OFREGISTER/GRILLE

45 INLET

AIRFLOW

ROUND SUPPLY DUCTSEE PLAN FOR SIZE

HORIZONTALLINE

15°

TURN BOOT COLLAR IN TOPROVIDE SMOOTH AIR FLOW

TO GRILLE.

16 GA. BOOT.SECURE TO DUCTAIRTIGHT

SUPPLY GRILLEFOR DETAILSSEE PLANS

OPPOSED BLADEDAMPER

TRANSFER AIR DUCT

RETURN AIR TRANSFER BOOT

1" THICK LINEDDUCT

TRANSFER AIRGRILL (TYP.)

1" THICK LINEDDUCT

SHT. MTL. NOSING OR APPROVEDSEALANT AT EXPOSED EDGES (TYP)

CAULK CONTINUOUS ATWALL PENETRATION (TYP.)

NOTE: OPENING FOR RETURN AIR INTAKE/OUTTAKE SHALL BE AT LEAST 12" CLEAR OF ANY STRUCTURAL MEMBERS.

1-1/2" UNISTRUT

STRUCTURE

CONDENSINGUNIT

PROVIDE 8" CLEARBETWEEN STRUCTUREAND CONDENSER.

GENERAL NOTE:

INLET SIDE OF CONDENSER FAN SHALLBE TOWARDS WALL. DISCHARGE SHALLFACE THE GARAGE OPEN AREA. PROVIDE12" CLEAR BETWEEN INLET OF CONDENSERAND WALL.

DISCHARGE DUCT.

FLEXIBLE CONNECTION.

BACKDRAFT DAMPER

HANGER RODS TO STRUCTURE ABOVE, TYPICAL

SPRING ISOLATORS, TYPICAL.

FLEXIBLE CONNECTION.

TRANSITION WHERE REQUIRED.

INTAKE DUCT.

TRANSITION WHERE REQUIRED.

30° MAXIMUM.

ACCESS DOOR. INSTALL FAN TO ALLOW DOOR TO BE COMPLETELY OPENED.

30° MAXIMUM

1. INSTALL FAN WITH PROPER SERVICE CLEARANCE TO MOTOR AND ALL PARTS FOR PROPER AIR MOVEMENT AS RECOMMENDED BY THE MANUFACTURER.

NOTE:

GAP

PIPE AND INSULATION WITH WATERPROOF ALUMINUM JACKET LONGITUDINAL SEAM AT BOTTOM

HIGH DENSITY INSULATIONWITH PIPE COVERING SHIELD

WALK PAD

PIPE CLAMP OFFSET

4" X 4" REDWOODSET IN MASTIC BED

ROOF

SECTION - A

DUCT SUPPORT DETAIL

2" STRAP

b" ISOMODE PAD

18 GAUGE HAT3"X3"X1" LEG

#10 TEK SCREW(TYPICAL)

NOTE:

1. DUCT WORK AND SUPPORT DESIGNATED FOR PAINTING ON FLOOR PLANS TO HAVE ALL JOINTS AND TAP-INS, E.T.C, SANDED SMOOTH TO A PAINT READY CONDITION FOR PAINTING BY OTHER.

A

-TRUSS#10 TEK SCREW(TYPICAL)

b" ISOMODE PAD

10 OR 18 GAUGERING X2" TOFIT DUCT

SPIRO DUCT26"Ø TO 32"Ø

TRUSS

SPIRO DUCT26"Ø TO 32"Ø

1-1/2"x1-1/2" ANGLESUPPORTS (TYP ALL

SIDES) DO NOT ATTACHTO WALL

10 GA SLEEVE (TYP)

INSULATION WHERENOTED

1/4" MINCLEARANCE

1" MINOVERLAPACCESS DOOR

OPERATOR/ACTUATOR24V OR 120V

TAXIWAY OPERATINGJACK SHAFT

FUSIBLE LINK WITH LOCK

USABLE ROD

INTEGRATOR SPRING

6" MAX (TYP ALL SIDES)

ROOF TOP UNIT

NOTE:

1. MECHANICAL CONTRACTOR TO COORDINATE ALL ROOF TOP UNITS, CURBS, SIZES AND ROOF OPENINGS WITH ROOFING CONTRACTOR.

2. CURB TO BE MINIMUM 18" ABOVE ROOF. PROVIDE SERVICE RAIL AS REQUIRED.

CURB

FLEXIBLE CONNECTION ONSA & RA DUCTS

SA & RA DUCTS. REFER TO ROOF PLAN.

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:47

:14

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M7.01

MECHANICAL DETAILS

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

NO SCALE1

DUCT MOUNTED AIR DEVICE DETAIL

NO SCALE2

DUCT MOUNTED SUPPLY GRILLEDETAIL

NO SCALE3

RETURN AIR TRANSFER BOOT AND AIRDUCT

JAN 09, 2019 PERMIT & BID

NO SCALE4

SUSPENDED CONDENSING UNIT DETAIL

NO SCALE5

INLINE FAN DETAIL

NO SCALE6

PIPE SUPPORT ON ROOF

NO SCALE9

DUCT SUPPORT TYPE "A"

NO SCALE7

COMBINATION FIRE SMOKE DAMPERDETAIL

NO SCALE8

RTU G-1 CURB DETAIL01-09-2019

Page 18: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:44

:02

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M7.02

MECHANICAL CODECOMPLIANCE

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

JAN 09, 2019 PERMIT & BID

01-09-2019

LAUREN BERRY

01/07/2019

LAUREN BERRY 01/07/2019

01-07-2019

Page 19: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

DUCT PRESSURE CLASSIFICATION SCHEDULE

DUCT TYPE

MEDIUM PRESSURE SUPPLY

LOW PRESSURE SUPPLY

MEDIUM PRESSURE EXHAUST

LOW PRESSURE EXHAUST

MEDIUM PRESSURE RETURN

LOW PRESSURE RETURN

GENERAL NOTES

1. DUCTWORK SHALL MEET ALL SMACNA REQUIREMENTS.

2. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION AND REQUIREMENTS, INCLUDING ALLOWABLE LEAKAGE.

3. NOTIFY THE ARCHITECT PRIOR TO INSTALLATION IF SYSTEMS ARE NOT SCHEDULED.

SYSTEM

ALL SUPPLY AIR

ALL SUPPLY AIR

ALL EXHAUST AIR

ALL EXHAUST AIR

ALL RETURN AIR

ALL RETURN AIR

SMACNA PRESSURE

CLASSIFICATION

+ 4"

+ 2"

- 4"

- 2"

- 4"

- 2"

INFORMATION

FROM AHU TO SAV, OR VAV

FROM SAV, VAV OR FCU TO GRD

FROM EAV TO FAN

FROM GRD TO EAV OR RAV

FROM RAV TO FAN

FROM GRD TO RAV

REMARKS

ELECTRIC DUCT HEATERCODE

(EDH)

C-1

GENERAL NOTES:

1. PROVIDE OVERCURRENT PROTECTION FOR ANY CIRCUIT OVER 48 AMPS.

2. SCHEDULED DIMENSIONS ARE DUCT DIMENSIONS.

3. PROVIDE AUTOMATIC AND MANUAL RESET THERMAL CUTOUTS.

4. PROVIDE DIFFERENTIAL PRESSURE AIRFLOW SWITCH.

5. PROVIDE CONTROL CIRCUIT TRANSFORMER.

6. TRANSITION DUCT WHERE REQUIRED TO COIL DIMENSIONS.

7. DISCONNECT TO BE PROVIDED BY EQUIPMENT MANUFACTURER.

8. PROVIDE SCR CONTROL.

9. MAINTAIN AT LEAST 4' OF STRAIGHT DUCT UPSTREAM AND DOWNSTREAM OF ELECTRIC COIL.

SERVICE

GYMNASIUM

CFM

16000

KW

150

DIMENSIONS

W" X H"

36X40

STEPS

SCR

EAT

(F)

55

LAT

(F)

85

ELECTRICAL

VOLT

480

PH

3

FLA

180

FUSE

200A FRS-R

DISC.

200A/3P

SECTION 23.05.30

FEEDER

RE: ELEC ONE LINE

REMARKS

ENVIRONMENTAL FAN SCHEDULE

CODE

EF G-1

EF G-2

EF G-3

EF C-1

EF C-2

REF C-1

TF G-1

TF C-1

GENERAL NOTES:

1. DRIVE TYPE: D = DIRECT-PROVIDE RHEOSTAT SPEED CONTROLLER IN FAN HOUSING UNLESS OTHERWISE NOTED.

B = BELT-PROVIDE ADJUSTABLE SHEAVE UNLESS OTHERWISE NOTED.

VFD = VARIABLE FREQUENCY DRIVE.

2. ALL CURBS SHALL BE FACTORY MADE, 14 INCH HIGH INSULATED UNLESS OTHERWISE NOTED.

3. SCHEDULED FAN VALUES (CFM, SP AND HP) ARE ACTUAL AT ALTITUDE. MOTOR HP HAS BEEN ADJUSTED FROM SEA LEVEL CONDITIONS FOR

OPERATION AT JOB SITE ELEVATION. JOB SITE ELEVATION = 0 FT.

4. PROVIDE MAGNETIC STARTER WITH AUXILARY CONTACTS AND HOA SWITCH ON ALL THREE PHASE UNITS EXCEPT WHEN

SERVED FROM MOTOR CONTROL CENTER.

5. PROVIDE PREMIUM EFFICIENCY MOTORS FOR MOTORS 1 HP AND OVER PER NEMA STANDARD MG1-2003, TABLES 12-12 AND 12-13.

6. REFER TO SPECIFICATIONS FOR ADDITIONAL MANUFACTURER'S THAT MAY BID AN EQUAL TO THE SCHEDULED BASIS OF DESIGN.

7. PROVIDE FANS WITH MANUFACTURER'S MOTORIZED SHUTOFF DAMPER.

MOUNTING (MTG):

1.PROVIDE WITH FACTORY MANUFACTURED ROOF CURB SUITABLE FOR ROOFING SYSTEM BEING USED. INSTALL

PER MANUFACTURER'S RECOMMENDATIONS. ALSO PROVIDE FACTORY BACKDRAFT DAMPER.

MANUFACTURER/

MODEL NO.

GREENHECK SQ-90-D

GREENHECK SP-A90-130-VG

GREENHECK SP-A90-130-VG

GREENHECK G-099-A

GREENHECK G-123-A

GREENHECK SQ-140-A

GREENHECK SQ-90-D

GREENHECK SQ-90-D

SERVICE

TOILET

TOILET

JANITOR'S CLOSET

TOILET/LOCKEROOM

TOILET/LOCKEROOM

STAGE

TRANSFER AIR

TRANSFER AIR

LOCATION

SIDEWALL/GARAGE LEVEL 1

SIDEWALL/GARAGE LEVEL 1

SIDEWALL/GARAGE LEVEL 1

ROOF

ROOF

STORAGE

ELECTRICAL ROOM

ELECTRICAL ROOM

TYPE

INLNE

CEILING MOUNTED

CEILING MOUNTED

CENT.

CENT.

INLINE

INLINE

INLINE

CFM

600

100

100

950

1600

1850

350

500

ESP

"W.C.

(ALT.)

0.25

0.25

0.25

.75

.75

.25

0.25

0.25

DRIVE

DIRECT

DIRECT

DIRECT

DIRECT

DIRECT

DIRECT

DIRECT

DIRECT

ELECTRICAL

HP

1/10

1/4

1/2

1

1/10

1/10

VOLT

115

115

115

115

115

460

115

115

PH

1

1

1

1

1

3

1

1

FLA

5.8

9.8

2.1

DISC.

$ TO

$ TO

$ TO

$ TO

$ TO

30A/3P

$ TO

$ TO

FEEDER

(2#12,#12G)3/4"C

(2#12,#12G)3/4"C

(2#12,#12G)3/4"C

(2#12,#12G)3/4"C

(2#12,#12G)3/4"C

(3#12,#12G)3/4"C

(2#12,#12G)3/4"C

(2#12,#12G)3/4"C

FUSE

-

-

-

-

-

3A FRS-R

-

-

MTG CTRL REMARKS

GRILLE REGISTER DIFFUSER SCHEDULE

CODE

A

B

C

D

E

F

G

GENERAL NOTES:

1. SEE PLANS FOR CFM AND NECK SIZE.

2. MAXIMUM NOISE CRITERIA (NC) SHALL BE 30 UNLESS OTHERWISE NOTED.

3. COLOR TO BE COORDINATED WITH ARCHITECT.

4. MATERIAL IS STEEL UNLESS OTHERWISE NOTED.

5. BALANCING DEVICE SHALL BE AT SPIN-IN TAP FOR ALL GRD'S UNLESS OTHERWISE NOTED.

6. PROVIDE SURFACE MOUNTING KIT FOR ALL PLAQUE DIFFUSERS LOCATED IN A GYP BOARD CEILING.

7. REFER TO SPECIFICATIONS FOR ALTERNATE MANUFACTURER'S THAT MAY BID AN EQUAL TO THE SCHEDULED BASIS OF DESIGN.

MANUFACTURER/

MODEL NO.

TITUS OMNI

TITUS OMNI

TITUS OMNI

TITUS 300RS

TITUS 301RS

TITUS 301RS

TITUS FL15

SERVICE

SUPPLY

EXHAUST

RETURN

SUPPLY

RETURN

EXHAUST

SUPPLY

TYPE

PLAQUE

PLAQUE

PLAQUE

GRILLE

GRILLE

GRILLE

SLOT

ACCESSORIES

NONE

NONE

NONE

NONE

NONE

NONE

NONE

FACE SIZE

24X24

24X24

24X24

SEE PLAN

SEE PLAN

SEE PLAN

SEE PLAN

REMARKS

LAY-IN

LAY-IN

LAY-IN

SURFACE MOUNT

SURFACE MOUNT

ROOF TOP UNIT SCHEDULE (DX COOLING)

CODE

(RTU)

C-1

G-1

GENERAL NOTES

1. PROVIDE PREMIUM EFFICIENCY MOTORS FOR MOTORS 1 HP AND OVER PER MENA STANDARD MG1-2003, TABLES 12-12 AND 12-13.

2. PROVIDE 2", 30% EFFICIENT FILTERS.

3. PROVIDE HIGH EFFICIENT FILTERS.

4. UNIT TO HAVE SINGLE POINT ELECTRICAL CONNECTION.

5. CAPACITY BASED ON 105F AMBIENT TEMPERATURE.

6. PROVIDE FULL PERIMETER MANUFACTURER'S ROOF CURB.

7. PROVIDE MANUFACTURERS RECOMMENDED SERVICE CLEARANCE AROUND ENTIRE UNIT.

8. HEATING AND COOLING CAPACITIES AND FAN STATIC PRESSURES ARE AT JOBSITE ALTITUDE.

9. JOBSITE ELEVATION= 0 FT.

10. PROVIDE DUCT SMOKE DETECTORS IN THE SUPPLY AIR OF ALL UNITS 2000 CFM OR GREATER.

11. CONTRACTOR SHALL COORDINATE MANUFACTURER'S ROOF CURB WITH STRUCTURAL ENGINEER.

12. UNIT SHALL COME EQUIPPED WITH ECONOMIZER AND ALL ASSOCIATED SENSORS, CONTROLS, AND DAMPERS FOR CHANGEOVER.

13. REFER TO SPECIFICATIONS FOR ALTERNATE MANUFACTURERS THAT MAY BID AS AN EQUAL TO THE BASIS OF DESIGN.

14. UNIT SHALL BE PROVIDED WITH LEAK DETECTION DEVICE IN DRAIN PAN THAT WILL SHUT OFF UNIT IN THE EVENT THAT THE PRIMARY DRAIN LINE BECOMES RESTRICTED.

15. PROVIDE UNIT WITH THYBAR VIBROCURB III WITH THEATER ACOUSTICS PACKAGE.

16. PROVIDE UNIT WITH SUPPLY FAN VFD INTEGRAL TO RTU BY MANUFACTURER.

17. PROVIDE MODULATING HOT GAS REHEAT.

REMARK NOTES

A. PROVIDE CUSTOM FULL PERIMETER MANUFACTURER'S SPRING ISOLATED ROOF CURB PLENUM FOR SIDE DISCHARGE. REFER TO SHEET M7.01.

MANUFACTURER/

MODEL

TRANE

TRANE

AREA

SERVED

COMMONS

GARAGE

SUPPLY FAN

CFM

10,500

7,700

ESP

(IN.)

2

1.5

FAN

QUANTITY

2

2

HP

(EA.)

5

3

MIN.

OSA

CFM

2,500

1,300

RELIEF AIR FAN

CFM

10,500

7,500

ESP

(IN.)

1

1

FAN

QUANTITY

2

1

HP

(EA.)

7.5

8

COOLING CAPACITY

EAT (F)

DB

80

78.5

WB

67.9

66.7

LAT (F)

DB

53.48

51.59

WB

53.42

51.52

TOTAL

MBH

464.95

335.06

SENS

MBH

303.71

214.22

ELECTRICAL

VOLT

460

460

PH

3

3

MCA

116

86

MOCP

125

100

FUSE

125A FRS-R

100A FRS-R

DISCON.

200A/3P

100A/3P

FEEDER

RE: ELEC ONE-LINE

RE: ELEC ONE-LINE

REMARKS

A

SPLIT SYSTEM SCHEDULEAHU COIL

CODE

AHU C-1

AHU C-2

GENERAL NOTES

1. PROVIDE DRAIN PAN WITH LEAK DETECTION THAT WILL SHUT DOWN UNIT IN THE EVENT THAT THE PRIMARY DRAIN BECOMES RESTRICTED.

2. PROVIDE PERMIUM EFFICIENCY MOTORS FOR MOTORS 1 HP AND OVER PER MENA STANDARD MG1-2003, TABLES 12-12 AND 12-13.

3. PROVIDE 2", 30% EFFICIENT FILTERS.

4. PROVIDE HIGH EFFICIENT FILTERS.

5. CAPACITY BASED ON 105F AMBIENT TEMPERATURE.

6. PROVIDE MANUFACTURER'S RECOMMENDED SERVICE CLEARANCE AROUND ENTIRE UNIT.

7. HEATING AND COOLING CAPACITIES AND FAN STATIC PRESSURES ARE AT JOBSITE ALTITUDE.

8. JOBSITE ELEVATION= 0 FT.

9. PROVIDE DUCT SMOKE DETECTORS IN THE SUPPLY AIR OF ALL UNITS 2000 CFM OR GREATER.

10. REFER TO SPECIFCATIONS FOR ALTERNATE MANUFACTURERS THAT MAY BID AS AN EQUAL TO THE BASIS OF DESIGN.

11. PROVIDE SINGLE POINT CONNECTION KIT.

REMARKS NOTES:

A. PROVIDE UNIT WITH SUPPLY FAN VFD INTEGRAL TO RTU BY MANUFACTURER.

B. UNIT SHALL BE EQUIPPED WITH ECONOMIZER AND ALL ASSOCIATED SENSORS, CONTROLS, AND DAMPERS FOR CHANGEOVER.

C. MECHANICAL CONTRACTOR TO PROVIDE ALL ASSOCIATED EQUIPMENT, SENSORS, CONTROLS, AND DAMPERS FOR ECONOMIZER OPERATION SEPARATE FROM UNIT.

CONDENSER

CODE

CU C-1

CU C-2.1

CU C-2.2

MANUFACTURER/

MODEL NO.

TRANE

TRANE

TRANE

AREA

SERVED

STAGE

GYM

GYM

SUPPLY FAN

CFM

1850

16000

NO. OF

FANS

1

2

HP

(EACH)

1

7.5

ESP

(IN.)

0.5

2

OA

CFM

450

3000

RETURN FAN

CFM

N/A

16000

NO. OF

FANS

2

HP

(EACH)

5

ESP

(IN.)

0.5

COOLING

ENTERING AIR

T (DB)

80.11

78.5

T (WB)

69.29

67

LEAVING AIR

T (DB)

55

55

T (WB)

55

54.1

COOLING CAPACITY

TOTAL

81.3

640.65

SENS.

49

412.57

ELECTRIC HEAT

ENTERING AIR

T

60

N/A

LEAVING AIR

T

90

CFM

1850

(KW)

TOTAL

20

CU ELECTRICAL

VOLT

-

460

460

PH

-

3

3

MCA

-

63

63

MOCP

-

70

70

FUSE

-

70A FRS-R

70A FRS-R

DISCON.

-

100A/3P

100A/3P

FEEDER

-

RE: ELEC ONE-LINE

RE: ELEC ONE-LINE

AHU ELECTRICAL

VOLT

460

460

460

PH

3

3

3

MCA

40

26.9

17.5

MOCP

-

-

-

FUSE

40A FRS-R

60A FRS-R

30A FRS-R

DISCON.

60A/3P

60A/3P

30A/3P

FEEDER

(3#8,#10G)3/4"C

(3#4,#8G)1"C

(3#10,#10G)3/4"C

REMARKS

C

A, B

VAV BOX SCHEDULE

CODE

(VAV)

C-1

C-2

C-3

C-4

C-5

C-6

C-7

C-8

G-1

G-2

G-3

G-4

G-5

G-6

GENERAL NOTES

1. CONTROLS SHALL BE BY MANUFACTURER OR BY CONTROL MANUFACTURER AND INSTALLED AT THE FACTORY (SEE SPECIFICATIONS).

2. MOUNT WITH 3 STRAIGHT DUCT DIAMETERS UPSTREAM OF THE BOX.

3. MAXIMUM NC LEVELS ARE RADIATED SOUND DATA AND BASED ON THE LISTED COOLING MAXIMUM CFM AND TOTAL APD LISTED.

4. HEATING COIL DISCHARGE TEMPERATURES SHALL NOT EXCEED 90F OR HAVE A TEMPERATURE RISE GREATER THAN 35F.

5. REFER TO SPECIFICATIONS FOR ALTERNATE MANUFACTURERS THAT MAY BID AN EQUAL TO THE SCHEDULED BASIS OF DESIGN.

AREA SERVED

STUDIO C112

RR/MISC

ENTRANCE HALLWAY C100

ENTRANCE HALLWAY C100

STORAGE/CONCESSION

OFFICE

LOCKERS

STUDIO C112

LOBBY

RR/CORRIDOR

MULTIPURPOSE G111

STORAGE MISC

YOUTH G110

SCOUTS G107

MANUFACTURER/

MODEL NO.

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

NAILOR 30RE

DESIGN CFM

COOLING

MAX

1550

640

1600

1600

1000

1000

1200

1400

900

500

1750

1230

1650

1600

HEATING

MAX

700

320

800

800

500

500

600

700

450

250

875

615

825

800

DESIGN

MIN

450

250

540

540

540

350

450

450

300

175

600

400

550

550

CAPACITY (CFM)

MAX.

2050

900

2050

2050

1500

1500

1500

2050

1500

900

2250

1500

2050

2050

MIN.

400

175

400

400

275

275

275

400

275

175

550

275

400

400

HEATING COIL

KW

7.9

3.6

9.0

9.0

5.6

5.6

6.8

7.9

5.1

2.8

9.9

6.9

9.3

9.0

CFM

700

320

800

800

500

500

600

700

450

250

875

615

825

800

EAT

55.0

55.0

55.0

55.0

55.0

55.0

55.0

55.0

55.0

55.0

55.0

55.0

55.0

55.0

LAT

90.0

90.0

90.0

90.0

90.0

90.0

90.0

90.0

90.0

90.0

90.0

90.0

90.0

90.0

ELECTRICAL

V

480

277

480

480

480

480

480

480

480

277

480

480

480

480

PH

3

1

3

3

3

3

3

3

3

1

3

3

3

3

FLA

9.5

13.0

10.9

10.9

6.8

6.8

8.1

9.5

6.1

10.1

11.9

8.3

11.2

10.9

FUSE

10A FRS-R

-

15A FRS-R

15A FRS-R

10A FRS-R

10A FRS-R

15A FRS-R

15A FRS-R

10A FRS-R

-

15A FRS-R

10A FRS-R

15A FRS-R

15A FRS-R

DISC.

30A/3P

$

30A/3P

30A/3P

30A/3P

30A/3P

30A/3P

30A/3P

30A/3P

$

30A/3P

30A/3P

30A/3P

30A/3P

FEEDER

(3#12,#12G)3/4"C

(2#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(2#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

MAX. NC @

BOX MAX.

30

30

30

30

30

30

30

30

30

30

30

30

30

30

INLET

SIZE

12

8

12

12

10

10

10

12

10

8

14

10

12

12

OUTLET

SIZE

20X12

14X12

16X16

16X16

16X12

16X12

20X12

20X12

14x12

10x10

18X16

14X14

16X16

16X16

TOTAL

APD

(IN.)

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

REMARKS

MINI SPLIT SYSTEM SCHEDULEFAN COIL

CODE

AC C-3

AC G-1

GENERAL NOTES

1. EAT=72F DB/WB.

2. PROVIDE DRAIN PAN WITH LEAK DETECTION THAT WILL SHUT DOWN UNIT IN THE EVENT THAT THE PRIMARY DRAIN BECOMES RESTRICTED.

3. PROVIDE CONDENSATE PUMP WITH ALL WALL MOUNTED AIR CONDITIONING UNITS.

CONDENSER

CODE

CU C-3

CU G-1

MANUFACTURER/

MODEL NO.

TRANE 4TYK6524A10N0B / 4MYW6524A10N0B

TRANE 4TYK612A10N0B / 4MYW6512A10N0B

AREA

SERVED

IDF C128

SERVER G114

SUPPLY FAN

CFM

500

300

COOLING CAP. (MBH)

TOTAL

24

12

SENS.

-

-

ELECTRICAL

VOLT

208

208

PH

1

1

MCA

16

10

MOCP

25

15

FUSE

20A FRN-R

15A FRN-R

DISCON.

30A/2P

30A/2P

FEEDER

(2#12,#12G)3/4"C

(2#12,#12G)3/4"C

REMARKS

UNIT HEATER SCHEDULE (ELECTRIC)CODE

(UH)

C-1

G-1

GENERAL NOTES

REMARK NOTES

A. PROVIDE UNIT MOUNTED CONTROLS.

B. HORIZONTAL DISCHARGE.

MANUFACTURER/

MODEL NO.

MODINE HER30

MODINE HER30

SERVICE

FIRE RISER C105

MECHANICAL G225

OUTPUT

(KW)

3

3

CFM

380

380

EAT

(F)

50

50

LAT

(F)

75

75

VOLT

480

480

PH

3

3

FLA

3.6

3.6

FUSE

5A FRS-R

5A FRS-R

DISCON.

30A/3P

30A/3P

FEEDER

(3#12,#12G)3/4"C

(3#12,#12G)3/4"C

REMARKS

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:54

:13

AM

C:\R

evi

t P

roje

cts\

20

18\M

E-S

t A

nn

e C

om

mo

ns

an

dG

ara

ge

-ME

PT

18

_M

uh

am

ma

d.A

lavi

7P

5A

X.r

vt

M8.00

MECHANICAL SCHEDULES

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

JAN 09, 2019 PERMIT & BID

01-09-2019

Page 20: 09 JANUARY 2019c-air-s.com/plans/5___Mechanical_Combined.pdf · cv constant volume db decibel db dry -bulb dc double duct constant volume direct current ddc direct digital control

0.80

419

450

CFM

CFM

ASHRAE STANDARD 62.1-2013 VENTILATION RATE PROCEDURE CALCULATIONS (PER TABLE 402.1 COH AMENDMENTS TO 2012 UMC) - AHU C-1

ROOM

NUMBER

C114

C115

C116

C117

System Ventilation Efficiency (Ev)

ASHRAE 62.1-2007 Required Outdor Air Intake (Vot)

Outdoor Air Scheduled

ZONE/ROOM NAME

TABLE & CHAIR STOR

GREEN RM

STAGE

OUTSIDE STOR.

ZONE TYPE

PER TABLE 6-1

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

STAGES, STUDIOS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

AREA

(Az)

(SQ.FT.)

215

269

742

358

OUTDOOR

AIRFLOW RATE

PER PERSON

(Rp)

CFM / PERSON

5

5

10

5

OUTDOOR

AIRFLOW RATE

PER UNIT

AREA (Ra)

CFM / SQ.FT.

0.06

0.06

0.06

0.06

OCCUPANT DIVERSITY

ZONE

POPULATION

PEOPLE/1000

SQ.FT.

2

2

70

2

100.0%

ZONE

POPULATION

(Pz)

0

0

24

0

24

OUTDOOR AIR

REQUIRED AT

BREATHING ZONE

CFM (Vbz)

13

16

285

21

335

ZONE AIR

DISTRIBUTION

EFFECTIVENESS

(Ez) TABLE 6-2

0.8

0.8

0.8

0.8

OUTDOOR

AIRFLOW RATE

CFM (Voz)

16

20

356

27

MINIMUM

ZONE

PRIMARY

AIRFLOW

CFM (Vpz)

200

250

1200

200

CRITICAL ZONE Zp

ZONE

PRIMARY

OUTDOOR

FRACTION

(Zp)

0.08

0.08

0.30

0.13

0.30

0.95

2,733

3,000

CFM

CFM

ASHRAE STANDARD 62.1-2013 VENTILATION RATE PROCEDURE CALCULATIONS (PER TABLE 402.1 COH AMENDMENTS TO 2012 UMC) - FCU C.2

ROOM

NUMBER

C113

System Ventilation Efficiency (Ev)

ASHRAE 62.1-2007 Required Outdor Air Intake (Vot)

Outdoor Air Scheduled

ZONE/ROOM NAME

GYMNASIUM

ZONE TYPE

PER TABLE 6-1

GYM, STADIUM (PLAY AREA)

AREA

(Az)

(SQ.FT.)

8656

OUTDOOR

AIRFLOW RATE

PER PERSON

(Rp)

CFM / PERSON

0

OUTDOOR

AIRFLOW RATE

PER UNIT

AREA (Ra)

CFM / SQ.FT.

0.3

OCCUPANT DIVERSITY

ZONE

POPULATION

PEOPLE/1000

SQ.FT.

30

100.0%

ZONE

POPULATION

(Pz)

41

41

OUTDOOR AIR

REQUIRED AT

BREATHING ZONE

CFM (Vbz)

2597

2,597

ZONE AIR

DISTRIBUTION

EFFECTIVENESS

(Ez) TABLE 6-2

0.8

OUTDOOR

AIRFLOW RATE

CFM (Voz)

3246

MINIMUM

ZONE

PRIMARY

AIRFLOW

CFM (Vpz)

16000

CRITICAL ZONE Zp

ZONE

PRIMARY

OUTDOOR

FRACTION

(Zp)

0.20

0.20

0.90

1,418

2,500

CFM

CFM

ASHRAE STANDARD 62.1-2013 VENTILATION RATE PROCEDURE CALCULATIONS (PER TABLE 402.1 COH AMENDMENTS TO 2012 UMC) - RTU C-1

ROOM

NUMBER

C112

C110

C100

C102

C101

C103

C104

C105

C120

C122

C123

C118

C119

System Ventilation Efficiency (Ev)

ASHRAE 62.1-2007 Required Outdor Air Intake (Vot)

Outdoor Air Scheduled

ZONE/ROOM NAME

STUDIO

CHEER

LOBBY

ADVANCEMENT STOR

CONCESSIONS

UCAL STOR

ATHLETIC STOR

P.E. INDOOR STOR

CONF

OFFICE

EAST CORRIDOR

BOYS LOCKER

GIRLS LOCKER

ZONE TYPE

PER TABLE 6-1

STAGES, STUDIOS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

MAIN ENTRY LOBBIES

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

CONFERENCE/MEETING

OFFICE SPACE

CORRIDORS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

AREA

(Az)

(SQ.FT.)

2061

161

2251

130

115

103

350

312

136

299

511

821

815

OUTDOOR

AIRFLOW RATE

PER PERSON

(Rp)

CFM / PERSON

10

5

5

5

5

5

5

5

5

5

0

5

5

OUTDOOR

AIRFLOW RATE

PER UNIT

AREA (Ra)

CFM / SQ.FT.

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

OCCUPANT DIVERSITY

ZONE

POPULATION

PEOPLE/1000

SQ.FT.

70

2

10

2

2

2

2

2

50

5

0

2

2

100.0%

ZONE

POPULATION

(Pz)

41

0

23

0

4

0

4

0

6

4

0

18

18

118

OUTDOOR AIR

REQUIRED AT

BREATHING ZONE

CFM (Vbz)

534

10

248

8

27

6

41

19

38

38

31

139

139

1,276

ZONE AIR

DISTRIBUTION

EFFECTIVENESS

(Ez) TABLE 6-2

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

OUTDOOR

AIRFLOW RATE

CFM (Voz)

667

12

310

10

34

8

51

23

48

47

38

174

174

MINIMUM

ZONE

PRIMARY

AIRFLOW

CFM (Vpz)

2800

140

3200

100

200

100

200

200

200

350

150

700

700

CRITICAL ZONE Zp

ZONE

PRIMARY

OUTDOOR

FRACTION

(Zp)

0.24

0.09

0.10

0.10

0.17

0.08

0.26

0.12

0.24

0.14

0.26

0.25

0.25

0.26

0.90

1,272

1,300

CFM

CFM

ASHRAE STANDARD 62.1-2013 VENTILATION RATE PROCEDURE CALCULATIONS (PER TABLE 402.1 COH AMENDMENTS TO 2012 UMC) - RTU G-1

ROOM

NUMBER

G100

G118

G118

G116

G119

G120

G101

G106

G107

G108

G109

G110

G111

G113

G114

G115

System Ventilation Efficiency (Ev)

ASHRAE 62.1-2007 Required Outdor Air Intake (Vot)

Outdoor Air Scheduled

ZONE/ROOM NAME

LOBBY

MULTI PURPOSE

YOUTH

SCOUTS

CORR-W

CORR-N

SECURITY

S.A.F.

SAF STORY

STOR 2

STOR 1

WORK

H.M. STOR

YOUTH STOR

GIRL STOR

BOY STOR

ZONE TYPE

PER TABLE 6-1

MAIN ENTRY LOBBIES

MULTI-USE ASSEMBLY

MULTI-USE ASSEMBLY

MULTI-USE ASSEMBLY

CORRIDORS

CORRIDORS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

OCCUPIABLE STORAGE ROOMS FOR DRY MATERIALS

AREA

(Az)

(SQ.FT.)

649

1167

1062

1165

660

271

101

194

157

157

160

164

162

167

158

147

OUTDOOR

AIRFLOW RATE

PER PERSON

(Rp)

CFM / PERSON

5

7.5

7.5

7.5

0

0

5

5

5

5

5

5

5

5

5

5

OUTDOOR

AIRFLOW RATE

PER UNIT

AREA (Ra)

CFM / SQ.FT.

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

0.06

OCCUPANT DIVERSITY

ZONE

POPULATION

PEOPLE/1000

SQ.FT.

10

100

100

100

0

0

2

2

2

2

2

2

2

2

2

2

100.0%

ZONE

POPULATION

(Pz)

6

32

32

32

0

0

0

0

0

0

0

0

0

0

0

0

102

OUTDOOR AIR

REQUIRED AT

BREATHING ZONE

CFM (Vbz)

71

310

304

310

40

16

6

12

9

9

10

10

10

10

9

9

1,145

ZONE AIR

DISTRIBUTION

EFFECTIVENESS

(Ez) TABLE 6-2

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

OUTDOOR

AIRFLOW RATE

CFM (Voz)

89

388

380

387

50

20

8

15

12

12

12

12

12

13

12

11

MINIMUM

ZONE

PRIMARY

AIRFLOW

CFM (Vpz)

750

1500

1500

1600

200

100

150

210

100

100

100

100

100

100

110

110

CRITICAL ZONE Zp

ZONE

PRIMARY

OUTDOOR

FRACTION

(Zp)

0.12

0.26

0.25

0.24

0.25

0.20

0.05

0.07

0.12

0.12

0.12

0.12

0.12

0.13

0.11

0.10

0.26

OUTSIDE AIR VERSUS EXHAUST AIR

COMMONS

UNIT

FCU-C-1

RTU-C-1

RTU-C-2

TOTAL

GARAGE

UNIT

RTU-G-1

AREA

STAGE

COMMONS

GYM

AREA

GARAGE

OUTSIDE AIR

450

2500

3000

5950

OUTSIDE AIR

1300

EXHAUST AIR

0

2550

0

2550

EXHAUST AIR

800

4550 Post Oak Place, Suite 344

Houston, TX 77027

P: +1.713.621.8690

www.me-engineers.com

1 2 4

D

3

1 2 4 53

C

B

A

D

C

B

A

5

SHEET NUMBER

SHEET TITLE

KEY PLAN

PROJECT NAME

PROJECT ADDRESS

DATE ISSUE

KIRKSEY PROJECT NO.

© 2018 Kirksey

Texas Firm Reg. No. F-10231

1/9

/20

19 8

:44

:03

AM

C:\R

evit P

roje

cts

\20

18\M

E-S

t A

nn

e C

om

mo

ns a

nd

Ga

rage

-ME

PT

18

_M

uh

am

ma

d.A

lavi7

P5A

X.r

vt

M8.01

MECHANICAL SCHEDULES

Commons & Parking Garage

2140 Westheimer RoadHouston, Texas 77098

2017187

1/8" = 1'-0" 1MEP SCHEDULES Copy 1

JAN 09, 2019 PERMIT & BID

01-09-2019